CYAPCO FINAL STATUS SURVEY RELEASE RECORD SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002

ý. e 5::)

Prepared By:

FSS EngineeS Reviewed '

F S Engine r Approved Bv:

CT Date: i/

Date: _I/______

Date:_____

Technical Support Manager Revision 0

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD TABLE OF CONTENTS

1.

SURVEY UNIT DESCRIPTION......................................................

3

2.

CLASSIFICATION BASIS................................................................

3

3.

DATA QUALITY OBJECTIVES (DQO)..........................................

5

4.

SUR V EY D ESIGN.............................................................................

8

5.

SURVEY IMPLEMENTATION.......................................................

11

6.

SURVEY RESULTS.........................................................................

12

7.

QUALITY CONTROL....................................................................

16

8.

INVESTIGATIONS AND RESULTS..............................................

16

9.

REMEDIATION AND RESULTS...................................................

17

10. CHANGES FROM THE FINAL STATUS SURVEY PLAN......

17

11. DATA QUALITY ASSESSMENT (DQA)......................................

17

12. A N O M A LIE S....................................................................................

17

13. C O N C LU SIO N..................................................................................

18

14. A TTA CHM EN TS.............................................................................

18 14.1 Attachment 1 - Figures (6 pages including cover) 14.2 Attachment 2 - Scan Results (6 pages including cover) 14.3 Attachment 3 - Laboratory Data (119 pages including cover) 14.4 Attachment 4 - DQA Results (14 pages including covers)

TOTAL 163 Revision 0

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9520-0002 (Southwest Site Storage Area) is designated as Final Status Survey (FSS) Class 2 and consists of 9,720 m2 (2.4 acres) of uninhabited open land located approximately 1,167 feet from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1). The survey unit is bounded as follows: land Survey Unit 9520-0001 to the north (called north as oriented with the north to south flow of the Connecticut River),

the Discharge Canal to the east, land Survey Unit 9520-0003 to the south, and the Connecticut River to the west. The survey unit is relatively level open space in the middle of the peninsula. The restoration of the peninsula for FSS has removed most of the surface interference in the survey unit.

The reference coordinates associated with this survey unit are E003 through E007 by S078 through S086 (refer to License Termination Plan (LTP) Section 5.4.4).

The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit.

The boundary of the survey unit was defined using a Global Positioning System (GPS) based on the Connecticut State Plane System North American Datum (NAD) 1927.

2.

CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification. "

The "Classification Basis Summary" conducted for Survey Unit 9520-0002 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial Characterization Report" and the "Historic Site Assessment Supplement, "

c) Historic and current survey records review, d) Visual inspections and a "walkdown."

A review of the 10CFR50.75(g)(1) database report and historical files shows a documented history of the use of this survey unit as a radioactive materials storage area. Additionally, at least one (1) case of contamination to underlying soil has been recorded (refer to survey performed 3/23/1985). Examples of some of the major events are provided below.

a) Plant Incident Report (PIR) 80-37 reported the discovery of three (3) discrete sources of elevated activity on the Southeast Site Storage area in March 1980, along with other areas around the site. Two (2) of the discrete sources were identified within adjacent Survey Unit 9520-0001.

The location of the third discrete source, identified as 3-24-2, was likely in Survey Unit 9520-0002 based on a review of the 1980 survey maps.

PIR 80-37 gave the likely cause of the third discrete source (and others Revision 0 3

Revision 0 3

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD found around the Site) as a series of operational events that had occurred since January 1979 that released a burst of air or steam through the ventilation ducts and out the Primary Vent Stack. The report included isotopic analysis of the third discrete source, which indicates a mixture of short lived fission products (e.g., Cs-134, Zr-95). The elevated areas were removed upon detection according to the report.

b) Health Physics surveys performed in 1983 and 1985 document the discovery of radioactive material (strainers, bolts, wood pallets, sections of pipe, etc.) on the peninsula.

The 1985 survey documents the discovery of contaminated dirt under a pallet.

c) Condition Report (CR) 05-0314: Documents the discovery of excavation spoils, intended for backfill, above the radiological criteria for use as backfill.

These spoils were located south of 9520-0002, probably in Survey Units 9520-003 and 9520-0004. According to the CR closure documentation, the affected spoils were removed and packaged for disposal. Follow-up survey and sampling was performed and the results were below established action levels.

A review of the "Initial and Supplemental Characterization Reports" as well as the previous "Classification Basis Summaries" was performed.

Survey Unit 9520-0002 was initially designated as Class 2 during the development of the LTP.

The source documents, the "Connecticut Yankee Haddam Neck Characterization Report" and "Initial Classification for Survey Areas at Connecticut Yankee", were incorporated by reference in LTP revision 0 (references 2-2 and 2-7 respectively). The second source document justified a Class 2 designation for those areas for which there was historical evidence of contamination above the Derived Concentration Guideline Levels (DCGLs -

refer to Section 2 for definition and description of DCGL), but for which recent surveys had shown that decontamination efforts had occurred and that the radiological conditions were expected to be below the DCGLs. Additional justification for a Class 2 designation based on survey and sampling data was provided as another reference to the LTP by the "Haddam Neck Plant Historical Site Assessment Supplement".

Removal of material and restoration of the peninsula for FSS has been ongoing since 2000, starting with the radiological release of the South Access Point and several abandoned trailers.

The collapse of the Radioactive Material(s) Area (RMA) boundary and removal of subsurface commodities has produced a large data set that has helped characterize the radiological contaminants of concern and extent of contamination. Although Co-60 has been identified in the past (refer to the "Haddam Neck Plant Historical Site Assessment Supplement"), Cs-137 has been the only radionuclide that has been consistently reported in concentrations above detection levels and with the potential to exceed the screening criteria (refer to Section 3).

Revision 0 4

Revision 0 4

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD Characterization was performed in August 2006 to support final classification and FSS planning.

Statistical quantities (mean, median and standard deviation) from the 2006 characterization survey conducted under SSWP 06-07-006 are provided in Table 1.

Table I

-OBasic StatisticanQuantities for Cs-137 fro:n the1.000 Characterization Minimum Observed Concentration (pCi/g):

1 I.86E-02 Maximum Observed Concentration (pCi/g):

1.13E-01 Mean (pCi/g):

6.06E-02 Median (pCi/g):

5.67E-02 Standard Deviation (pCi/g):

3.73E-02 The FSS Engineer performed a visual inspection and walk-down during September 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024) which will be a source of dose from residual radioactivity, as discussed in Section 3 under the Data Quality Objectives.

Based upon the results of radiological surveys performed over six years of restoration and the 2006 characterization survey, it was concluded that there was a low probability for residual radioactivity in concentrations greater than the DCGLs, justifying a final survey unit classification of Class 2 (refer to Section 3).

3.

DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparation of Final Status Survey Plan, " and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would indicate that residual activity within the survey unit does not exceed the release criteria. Therefore, the survey unit does satisfy the primary objective of the FSS plan.

Revision 0 5

Revision 0 5

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD The primary objective of the FSS plan was to demonstrate that the level of residual radioactivity in Survey Unit 9520-0002 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity.

This is done through the development of DCGLs. The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity that will be contributed by building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity.

Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation I HTota! = Hsoil + HExistingGW + HFutureGW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three (3) components.

The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for CY is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024).

Therefore, the dose contribution from existing groundwater is bounded by two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no buried concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.

Equation 2 19 mrem/yrTotal = 17 mrem/yrsoil + 2 mrem/yrExisting GW+ 0 mrem/yrFutureGw Revision 0 6

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD The allowable dose for soil in this survey unit is seventeen (17) mrem!yr TEDE as shown by Equation 2 above.

The concentration of residual radioactivity resulting in seventeen (17) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.

T~able 2 - Radionuclide Specific Base Case Soil DCGL, Operational DSG("Is~

adRequired Mlinimium Detectable Concentrations~

~Radionuiclide Base Cvase Soil Operational DCGI.

Required NMDC 1)___

CG L (1) (, ig)(2)

(pCi/g> (3

~(Pdi/g) "I H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+OI 6.96E-01 Fe-55 2.74E+04 1.86E+04

1. 1 0E+03 Co-60 3.81 E+00 2.59E+00 1.52E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+0i Pu-238 2.96E+O1 2.01E+01 1.1 8E+00 Pu-239/240 2.67E+O1 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 )

2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+0 I 1.97E+0 1 1.1 6E+00 kI) Hold inuicates tnose raolonuciues consiaerea to De -ara-to-uetect tji I U)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to I mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD); the preferred result is the alpha spectroscopy's when both analyses are performed Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability.

Soil samples were collected in 2006 to establish the radiological condition of Survey Unit 9520-Revision 0 7

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD 0002 for FSS. Cs-137 was the only gamma emitting radionuclide reported in concentrations with the potential for exceeding the screening criteria.

The characterization data were used for the survey design and are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (MDC) were not accepted for FSS.

Sample report summaries included unique sample identification, analytical

method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
4.

SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans". The FSS plan uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

The DQO process determined that Cs-137 would be the radionuclide of concern in Survey Unit 9520-0002 (refer to Section 3). Other radionuclides identified during this FSS would be evaluated to ensure adequate survey design.

Surrogate DCGLs were not required for this survey unit via screening under LTP Section 5.4.7.2, "Gross Activity DCGLs". Radionuclide screening or de-selection is a process where an individual radionuclide or aggregates may be considered insignificant and eliminated from the FSS.

The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation.

This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Surface Samples for Final Status Survey." The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 5.31 to maintain the relative shift Revision 0 8

Revision 0 8

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD (A/cy) in the range of 1 and 3. The resulting Adjusted Relative Shift was 2.0. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.

The survey design specified fifteen (15) surface soil samples for non-parametric statistical testing and five (5) samples at biased locations.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locations for Final Status Survey."

Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.

Judgmental sampling was included as a feature of this survey design to account for any anomalies potentially identified in the field.

Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Table 3 - ~Sample Measurement Locations with Assonciated GPS Coordinates

>DesigwktioQn>

7Northing

~

Fs I Esing 9520-0002-001F 235939.59 669151.81 9520-0002-002F 235939.59 669241.40 9520-0002-003F 235862.00 669107.01 9520-0002-004F 235862.00 669196.60 9520-0002-005F 235862.00 669286.19 9520-0002-006F 235862.00 669375.78 9520-0002-007F 235784.41 669151.81 9520-0002-008F 235784.41 669241.40 9520-0002-009F 235784.41 669330.99 9520-0002-01 OF 235784.41 669420.58 9520-0002-011 F 235784.41 669510.16 9520-0002-012F 235706.83 669286.19 Revision 0 9

Revision 0 9

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD Table 3.- Sample~Meastiremient Locations wýith Akssociated GPS Coordinates

~*DeignaionNorhilig F asIting, 9520-0002-013F 235706.83 669375.78 9520-0002-014F 235706.83 669465.37 9520-0002-015F 235629.24 669420.58 9520-0002-016F 235930.63 669114.38 9520-0002-017F 235945.94 669124.95 9520-0002-018F 235912.47 669322.50 9520-0002-019F 235814.98 669514.90 9520-0002-020F 235886.05 669156.64 Procedure RPM 5.1-11 specifies that 5% of the samples are required to be selected for HTD analysis. Two (2) soil samples, or about 10% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel "RANDBETWEEN" function. Each sample was sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, "Radionuclides Potentially Present at Haddam Neck Plant" and as provided in Table 2.

The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey," included the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RANDBETWEEN" function. The number of quality control soil samples was about 10% of fifteen (15) samples.

The LTP specifies a required scanning coverage of 10% to 100% for outdoor Class 2 areas. The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS. Based on the historical site assessment, the characterization data available, and the use of the survey unit to store spoils from remediation, it was determined that scanning was required in four (4) separate areas. The total surface area to be scanned was approximately 40% of the survey unit. One of the scan areas provided 100% coverage of the area where, based on a review of the 1980 survey maps, the discrete source of elevated activity was found. A map of the scan grid locations is provided in.

Revision 0 10 Revision 0 10

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD For this Class 2 survey unit, the "Investigation Level" for area scanning and soil sample measurement results are those levels specified in LTP, Table 5-8. Table 4 provides a synopsis of the survey design.

Table

-~Sý ijopsis of the Sur'ev Design

~ Feature Desig C~riteria

~

~<Basis ~

Survey Unit Land Area 9,720 m2 Based on AutoCAD-LT Type I and Type 2 errors were 20 0.05, sigma was 0.037 pCi/g, Number of Measurements (15 systematic grid) the LBGR was adjusted to 5.31 (5 biased) to maintain Relative Shift in the range of 1 and 3 Grid Spacing 27.4 m Based on triangular grid Administratively set to achieve Operational DCGL 5.38 pCi/g Cs-137 17 mrem/yr TEDE (1)

The Operational DCGL meets Soil Investigation Level 5.38 pCi/g Cs-137 the LTP criteria for a Class 2 survey unit Scan Survey Area Approximately 40%

The LTP requires >10% area eof the area coverage for Class 2 survey units Detectable over Administratively set to achieve background 17 mrem/yr TEDE (1)

(1) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)

5.

SURVEY IMPLEMENTATION FSS field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0038. The WP&IR package included a detailed FSS plan, job safety analysis, job planning checklist and related procedures for reference.

Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.

Four (4) scan areas were established that constituted approximately 40% of the surface area of Survey Unit 9520-0002.

Grid lines, one meter wide, were painted on the ground of the scan area. A background survey was performed around the survey unit and it was determined that, using an Eberline E-600 with a SPA-3 sodium iodide detector, background ranged from 5,350 counts per minute (cpm) up to 8,940 cpm.

The scan areas were established and scanned for elevated readings (see for all scan results). Scanning was performed with an Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close Revision 0 I1I Revision 0 II

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 40% of the survey unit was scanned.

Measurement locations were identified in North American Datum (NAD) 1927 coordinates using GPS coordinates; sample locations were identified and marked with a surveyor's flag or paint for identification.

At each sample location, a one (1) meter radius around the sample flag or paint mark was scanned for elevated radiation levels.

Twenty-four (24) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design.

Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples."

Two (2) samples (9520-0002-008F and 9520-0002-015F) were randomly selected for HTD radionuclide analysis.

The implementation of survey specific quality control measures included the collection of two (2) samples (9520-0002-01 IF and 9520-0002-012F) for "split sample" analysis.

6.

SURVEY RESULTS All field survey activities were conducted between October 9, 2006 and October 16, 2006.

The sample locations identified in the FSS plan were scanned over approximately a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan results for sample measurement locations.

Scan results are provided in Attachment 2.

Table 5 - Scan Results for Sample Measurement L:ocations g

Sample Highest Logged Ato ee MNeasujreml jiVt Readhing 4

kctio LeelAciioiv Level Loain(kcpm)

(cm 1

8.24 8.87 NO 2

6.41 8.59 NO 3

10.40 10.00 YES 4

8.22 8.39 NO 5

7.53 9.96 NO 6

7.02 9.07 NO 7

7.03 7.50 NO 8

7.87 8.56 NO Revision 0 12 Revision 0 12

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD 9

10 6.01 6.76 NO 11 7.51 7.85 NO 12 6.97 7.02 NO 13 6.72 8.43 NO 14 7.07 8.48 NO 15 6.64 6.94 NO 16 7.38 10.00 NO 17 7.98 8.25 NO 18 6.36 6.98 NO 19 6.16 7.25 NO 20 8.00 8.50 NO (1) The action level is based on a measurement above ambient background in accordance with the FSS plan (2) The FSS plan requires movement of the sample measurement location to the area within the 1 meter radius yielding the response above the action level The scan areas, that comprised approximately 40% of the total surface area for the survey unit, were scanned for elevated radiation levels.

The areas were scanned in accordance with the FSS plan on October 9, 2006 through October 16, 2006.

Several elevated measurement locations were identified during scanning. Table 6 provides an overview of the scan area survey. Scan results are provided in Attachment 2.

Action Level ~

lvtdInvestigation (cprn)j$

Reading

()

Sa1ni1ple Identi~fication (2 1

1 9.40 7.56 9520-02-ER 16-1 9520-0002-024F None - no 2

7.88 9.17 elevated areas None identified Revision 0 13 Revision 0 13

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD T17111e 6 -Scan Area Results' Highest Elevated Scain Logged Action Level RednInvestig.tkion~

rea = =

=;

Reading*

Area

Reading, f(kc

)

d h

T, (2)

S Sa IIIple (kcpmi)

Identification 3

9.14 7.64 9520-02-ER 9520-0002-023F 10-1 9520-02-ER 9520-0002-021 F 10-1 4

9.43 9.03 1-9520-02-ER 9520-0002-022F 10-2 (1) The action level is based on a measurement above ambient background (2) ER is an abbreviation associated with the barcodes used in the field where ER stands for Elevated Reading The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC. The laboratory analyzed the fifteen (15) samples collected for non-parametric statistical testing, the associated field splits, the five (5) biased samples, and the four (4) confirmatory samples using gamma spectroscopy.

Gamma spectroscopy analysis was performed to the required MDCs.

Gamma spectroscopy results identified some radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty). However, Cs-137 was the only radionuclide reported in concentrations exceeding the de-selection criteria.

Cs-137 was identified in thirteen (13) of the fifteen (15) samples collected for non-parametric statistical testing.

Cs-137 was the primary radionuclide confirming the DQOs. The mean of the gamma spectroscopic analysis results for the sample population indicated that Cs-13 7 was present at levels lower than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.

A summary of the fifteen (15) samples collected for non-parametric statistical testing results is provided in Table 7.

LiZU-UUUZ-UU IP J.I ot-U 9520-0002-002F 9.53E-02 0.018 9520-0002-003F 3.16E-02 0.006 9520-0002-004F 1.13E-01 0.021 9520-0002-005F 0.OOE+00 0.000 Revision 0 14 Revision 0 14

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD 9520-0002-007F 1.16E-01 0.022 9520-0002-008F 8.01E-02 0.015 9520-0002-009F 8.34E-02 0.016 9520-0002-01OF 4.16E-02 0.008 9520-0002-011 F 9.08E-02 0.017 9520-0002-012F 3.30E-01 0.061 9520-0002-013F 2.03E-01 0.038 9520-0002-014F 9.68E-02 0.018 9520-0002-015F 1.67E-01 0.031

(])The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE The off-site laboratory also processed two (2) samples for HTD analysis as required by the sample plan.

The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC.

As previously stated in Section 4 of this report, the criteria for de-selection of a radionuclide is a concentration that is less than 5% of the Operational DCGL for individual radionuclides and less than 10% of the Operational DCGLs for aggregates. Sr-90 and Tc-99 were the only HTDs, which by analysis, met the criteria for detection (i.e., a result greater than two standard deviations uncertainty). The highest result for both Sr-90 and Tc-99 was at about 4% of the Operational DCGL.

  • D2U-UUU--Uo-Z.1 4t-UZ M.020U 1.4

-o-UI oI.o/

I 9520-0002-015F 3.54E-02 0.034 2.85E-01 0.033 (1) The Operational DCGL from Table 2 is 1.05 pCi/g for Sr-90 and 8.57 for Tc-99 to achieve 17 mrem/yr TEDE Revision 0 15 Revision 0 15

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD Five (5) biased samples were collected at locations selected by FSS Supervision based on professional judgment and observation. Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC.

9520-0002-017F 4.22E-02 0.038 9520-0002-018F 1.19E-01 0.029 9520-0002-019F 1.07E-01 0.031 9520-0002-020F 6.19E-02 0.052 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE

7.

QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis.

Ten percent (10%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey". There was acceptable agreement between the field split results at both locations (9520-0002-011 and 9520-0002-012).

The sample analysis vendor, General Engineering Laboratories, LLC, maintains quality control and quality assurance plans as part of normal operation. Refer to for data and data quality analysis results.

8.

INVESTIGATIONS AND RESULTS Four confirmatory samples were collected from scan area 1, scan area 3 and scan area 4 at locations exhibiting elevated scan readings. The samples are denoted as shown in Table 6, with the sample results shown in Table 10 below.

9520-0002-022F 9.02E-02 0.024 9520-0002-023F 4.19E-02 0.026 9520-0002-024F 4.69E-02 0.026 (1) The Operational DCGL from Table 2 is 5.38 pCi/g for Cs-137 to achieve 17 mrem/yr TEDE Revision 0 16 Revision 0 16

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD

9.

REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria is unnecessary and that the remaining residual radioactivity in soil was ALARA.

10.

CHANGES FROM THE FINAL STATUS SURVEY PLAN No changes were made to the FSS plan.

11.

DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment, " for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs.

The evaluation of the Sign Test results demonstrates that the survey unit passes the unrestricted release criteria, thus, the null hypothesis is rejected.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The mean and median values are well below the Operational DCGL. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.

Therefore, the survey unit meets the unrestricted release criteria with adequate power as required by the DQOs.

For Cs-137, the range of the data, about four (4) standard deviations, was not a particularly large variation considering that the levels were essentially at existing environmental levels where such variation is to be expected.

The difference between the mean and median was about 15% of the standard deviation which indicates slight skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot indicates positive skewness as confirmed by the calculated skew of 1.66.

All data, assessments, and graphical representations are provided in Attachment 4.

12.

ANOMALIES No anomalies were noted.

Revision 0 17 Revision 0 17

SOUTHWEST SITE STORAGE AREA SURVEY UNIT 9520-0002 RELEASE RECORD

13.

CONCLUSION Survey Unit 9520-0002 has met the final DQOs of the FSS plan. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation was not required.

Cs-137 was used for statistical testing to determine the adequacy of the survey unit for FSS.

The sample data passed the Sign Test. The null hypothesis was rejected.

The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit is properly designated as Class 2.

The dose contribution from soil is less than 1 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey area is affected by existing groundwater (reference CY memo ISC 06-024); therefore the dose contribution from existing groundwater is bounded at two (2) mrem/yr TEDE.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no underground structures, systems or components containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024); therefore, the dose contribution from future groundwater is zero (0) mrem/yr TEDE.

The average total dose from residual radioactivity in this survey unit, including exposures from the three (3) components as described in Section 3, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity, will not exceed 3 mrem/yr TEDE.

Therefore, Survey Unit 9520-0002 is acceptable for unrestricted release.

14.

ATTACHMENTS 14.1 Attachment 1 - Survey Unit Location Map 14.2 Attachment 2 - Scan Results 14.3 Attachment 3 - Laboratory Results 14.4 Attachment 4 - DQA Results Revision 0 18

CENTRAL PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 1 (FIGURES)

$00 010

/I ReeWW" COWja~tv Spjetwf B.,dhfM3*

NVorMk,9 _ 2_85&".39 / Eastkg -

WW536.14 171 v

mMor_-_;-

It

.XIN I

j-rcoAWClTCUT RMFR 4-Connecticut Yankee Atomic Power Company Site Map With Reference To Survey Unit 9520-0002

0-z;)

5 44 0

25 50

, IIIII Feet

-I 9

4 I&

Connecticut Yankee Atomic Power Company Survey Unit 9520-0002 Final Status Survey Design

4.-

f 0.04 0

25 50IFeet 0.10 0.08 Notes Reported Concentrations in pCi/g 0.11 0.03 I&

Connecticut Yankee Atomic Power Company Survey Unit 9520-0002 Final Status Survey Cs-137Posting Plot

-SciAwe 0

25 50 SFeet Notes Bdwkv-dzzv fom5Ak1qmz a 8.9 kcpm as deftumied byma E60witb SPA-3 Probe Raefff t Tabl 6kwr w= -v raulla Connecticut Yankee Atomic Power Company Survey Unit 9520-0002 Final Status Survey Scan Areas

D-SmanAm 0

25 50 E':::Z Foe Notes Refer t Tsbk 9 for b&"sd smplreffdnk Refirto Table 10 for Cmzfnnakuywnple yeubk Connectcut Yankee Atomic Power Company Survey Unit 9520-0002 Final Status Survey Biased and Confirmatry Samples

CENTRAL PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 2 (SCAN RESULTS)

Survey Release Record Sample Location Scan Results Survey Unit 9520-0002 Sample Name

Background

(CPM)

Action Level Results Above LCIM)

AL Loq Date Lon Time E600 SIN Probe SIN 9520-02-SL-00-01-0 9520-02-SL-00-02-0 9520-02-SL-00-03-0 9520-02-SL-00-04-0 9520-02-SL-00-05-0 9520-02-SL-00-06-0 9520-02-SL-00-07-0 9520-02-SL-00-08-0 9520-02-SL-00-09-0 9520-02-SL-00-10-0 9520-02-SL-00-1 1-0 9520-02-SL-00-12-0 9520-02-SL-00-1 3-0 9520-02-SL-00-14-0 9520-02-S L-00-i 5-0 9520-02-SL-00-16-0 9520-02-SL-00-17-0 9520-02-SL-00-1 8-0 9520-02-SL-00-19-0 9520-02-SL-00-20-0 7.62E+03 7.36E+03 8.67E+03 7.18E+03 8.63E+03 7.81 E+03 6.36E+03 7.34E+03 7.01E+03 5.68E+03 6.68E+03 5.92E+03 7.22E+03 7.26E+03 5.85E+03 8.67E+03 7.05E+03 5.88E+03 6.13E+03 7.28E+03 8.87E+03 8.59E+03 1.OOE+04 8.39E+03 9.96E+03 9.07E+03 7.50E+03 8.56E+03 8.21 E+03 6.76E+03 7.85E+03 7.02E+03 8.43E+03 8.48E+03 6.94E+03 1.OOE+04 8.25E+03 6.98E+03 7.25E+03 8.50E+03 8.24E+03 6.41 E+03 1.04E+04 8.22E+03 7.53E+03 7.02E+03 7.03E+03 7.87E+03 7.18E+03 6.01E+03 7.51 E+03 6.97E+03 6.72E+03 7.07E+03 6.64E+03 7.38E+03 7.98E+03 6.36E+03 6.16E+03 8.OOE+03 10/9/2006 10/9/2006

+

10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10/9/2006 10:49:00 11:01:00 7:48:00 8:12:00 9:45:00 10:23:00 11:11:00 9:30:00 1008:00 13:12:00 13:46:00 11:25:00 13:37:00 13:35:00 14:12:00 7:34:00 10:35:00 14:27:00 13:57:00 7:59:00 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9520-0002 9520-0002 SCAN AREA 1 Sample Name 9520-02-SC-01-01-0 9520-02-SC-01-02-0 9520-02-SC-01-03-0 9520-02-SC-01-04-0 9520-02-SC-01-05-0 9520-02-SC-01-06-0 9520-02-SC-01-07-0 9520-02-SC-01-08-0 9520-02-SC-01-09-0 9520-02-SC-01-10-0 9520-02-SC-01-11-0 9520-02-SC-01-12-0 9520-02-SC-01-13-0 9520-02-SC-01-14-0 9520-02-SC-01-15-0 9520-02-SC-01-16-0 9520-02-ER-01-16-1 9520-02-SC-01-17-0 9520-02-SC-01-18-0 9520-02-SC-01-19-0 9520-02-SC-01-20-0 9520-02-SC-01-21-0 9520-02-SC-01-22-0 9520-02-SC-01-23-0 9520-02-SC-01-24-0 9520-02-SC-01-25-0 9520-02-SC-01-26-0 9520-02-SC-01-27-0 9520-02-SC-01-28-0

Background

(cPM) 6.74E+03 5.77E+03 6.01 E+03 5.99E+03 6.13E+03 5.71EE+03 5.56E+03 5.68E+03 5.57E+03 5.67E+03 5.35E+03 5.74E+03 5.65E+03 6.63E+03 6.14E+03 6.42E+03 6.42E+03 7.92E+03 6.55E+03 6.30E+03 6.92E+03 7.12E+03 7.73E+03 7.05E+03 8.53E+03 843E+03 7.66E+03 8.94E+03 8.60E+03 Action Level (cPM) 7.91 E+03 6.85E+03 7.12E+03 7.1OE+03 7.25E+03 6.79E+03 6.62E+03 6.76E+03 6.64E+03 6.75E+03 6.39E+03 6.82E+03 6.72E+03 7.79E+03 7.26E+03 7.56E+03 7.56E+03 9.19E+03 7.71 E+03 7.43E+03 8.11 E+03 8.32E+03 8.99E+03 8.25E+03 9.85E+03 9.74E+03 8.91 E+03 1.03E+04 9.92E+03 Results 6.27E+03 6.06E+03 6.10E+03 5.55E+03 5.55E+03 5.21 E+03 5.36E+03 5.94E+03 6.OOE+03 6.04E+03 5.55E+03 5.66E+03 5.93E+03 6.28E+03 6.41 E+03 6.39E+03 9.40E+03 6.04E+03 6.13E+03 6.46E+03 6.87E+03 7.93E+03 6.61 E+03 7.96E+03 7.75E+03 7.33E+03 7.94E+03 8.68E+03 7.37E+03 Above AL Loq Date Log Time E600 S/N Probe S/N 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006

+

10/16/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 8:22:00 8:27:00 9:39:00 9:46:00 9:52:00 10:00:00 10:07:00 10:12:00 10:19:00 10:23:00 10:33:00 10:37:00 10:42:00 10:46:00 10:53:00 11:01:00 13:23:00 11:07:00 11:12:00 11:20:00 11:25:00 13:39:00 13:41:00 13:44:00 13:50:00 13:53:00 13:59:00 14:04:00 14:09:00 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1107 1105 1107 1107 1107 1107 1111 1111 1111 1111 1111 1111 1111 1111 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1003 1012 1003 1003 1003 1003 1004 1004 1004 1004 1004 1004 1004 1004 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9520-0002 9520-02-SC-01-29-0 9520-02-SC-01-30-0 9520-02-SC-01-31-0 9520-02-SC-01-32-0 9520-02-SC-01-33-0 9520-02-SC-01-34-0 9520-02-SC-01-35-0 9520-02-SC-01-36-0 9520-02-SC-01-37-0 9520-02-SC-01-38-0 9520-02-SC-01-39-0 9520-02-SC-01-40-0 9520-02-SC-01-41-0 9520-02-SC-01-42-0 8.10E+03 7.80E+03 8.36E+03 7.81 E+03 7.41 E+03 7.33E+03 7.24E+03 7.66E+03 7.20E+03 6.64E+03 7.45E+03 6.37E+03 5.75E+03 5.52E+03 9.39E+03 9.06E+03 9.67E+03 9.07E+03 8.64E+03 8.55E+03 8.46E+03 8.91 E+03 8.41 E+03 7.80E+03 8.68E+03 7.51 E+03 6.83E+03 6.58E+03 9.15E+03 8.63E+03 8.79E+03 7.63E+03 7.55E+03 6.88E+03 7.04E+03 6.57E+03 7.54E+03 6.58E+03 7.24E+03 7.29E+03 6.11E+03 6.16E+03 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 10/13/2006 14:15:00 14:19:00 14:23:00 14:26:00 14:29:00 14:32:00 14:35:00 14:41:00 14:45:00 14:49:00 14:52:00 14:55:00 15:00:00 15:03:00 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1004 1004 1004 1004 1004 1004 1004 1004 1004 1004 1004 1004 1004 1004 9520-0002 SCANAREA 2

Background

Sample Name (cDM) 9520-02-SC-02-01-0 7.13E+03 9520-02-SC-02-02-0 7.12E+03 9520-02-SC-02-03-0 7.22E+03 9520-02-SC-02-04-0 6.43E+03 9520-02-SC-02-05-0 7.90E+03 9520-02-SC-02-06-0 6.27E+03 9520-02-SC-02-07-0 7.07E+03 9520-02-SC-02-08-0 7.24E+03 9520-02-SC-02-09-0 6.60E+03 9520-02-SC-02-10-0 6.94E+03 9520-02-SC-02-11-0 6.92E+03 9520-02-SC-02-12-0 6.80E+03 9520-02-SC-02-13-0 6.53E+03 9520-02-SC-02-14-0 7.1 OE+03 Action Level (C8M) 8.34E+03 8.32 E+03 8.43E+03 7.58E+03 9.17E+03 7.40E+03 8.27E+03 8.46E+03 7.76E+03 8.13E+03 8.11E+03 7.98E+03 7.68E+03 8.30E+03 Results 6.03E+03 6.71 E+03 6.81 E+03 6.42E+03 7.88E+03 7.29E+03 6.28E+03 7.55E+03 6.59E+03 6.20E+03 6.99E+03 6.33E+03 6.84E+03 6.58E+03 Above AL Log Date Log Time E600 SIN Probe SIN 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10/12/2006 10:14:00 10:19:00 10:24:00 10:30:00 10:54:00 11:00:00 11:03:00 11:08:00 11:12:00 11:17:00 11:20:00 13:02:00 13:06:00 13:08:00 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9520-0002 9520-02-SC-02-15-0 9520-02-SC-02-16-0 9520-02-SC-02-17-0 9520-02-SC-02-18-0 7.05E+03 6.66E+03 6.85E+03 6.50E+03 8.25E+03 7.83E+03 8.03E+03 7.65E+03 6.72E+03 6.64E+03 7.12E+03 6.93E+03 10/12/2006 10/12/2006 10/12/2006 10/12/2006 13:13:00 13:16:00 13:21:00 13:24:00 1105 1105 1105 1105 1012 1012 1012 1012 9520-0002 SCAN AREA 3 Sample Name 9520-02-SC-03-01 -0 9520-02-SC-03-02-0 9520-02-SC-03-03-0 9520-02-SC-03-04-0 9520-02-SC-03-05-0 9520-02-SC-03-06-0 9520-02-SC-03-07-0 9520-02-SC-03-08-0 9520-02-SC-03-09-0 9520-02-SC-03-10-0 9520-02-ER-03-1 0-1 9520-02-SC-03-1 1-0 9520-02-SC-03-12-0 9520-02-SC-03-13-0 9520-02-SC-03-14-0 9520-02-SC-03-15-0 9520-02-SC-03-16-0 9520-02-SC-03-17-0 9520-02-SC-03-18-0 9520-02-SC-03-19-0 9520-02-SC-03-20-0 9520-02-SC-03-21-0 9520-02-SC-03-22-0 9520-02-SC-03-23-0

Background

106M)+

6.66E+03 6.67E+03 7.15E+03 6.53E+03 7.OOE+03 6.30E+03 7.84E+03 6.74E+03 7.58E+03 6.49E+03 6.49E+03 7.36E+03 6.61 E+03 6.84E+03 6.42E+03 7.50E+03 7.17E+03 7.55E+03 6.75E+03 7.25E+03 7.35E+03 6.52E+03 6.65E+03 6.90E+03 Action Level 7c3m) 7.83E+03

7. 84E+03 8.36E+03 7.68E+03 8.19E+03 7.43E+03 9.1OE+03 7.91 E+03 8.82E+03 7.64E+03 7.64E+03 8.59E+03 7.77E+03 8.02E+03 7.56E+03 8.74E+03 8.38E+03 8.79E+03 7.92E+03 8.47E+03 8.57E+03 7.67E+03 7.81 E+03 8.09E+03 Results 6.92E+03 6.44E+03 6.38E+03 6.50E+03 7.32E+03 6.87E+03 6.99E+03 6.56E+03 6.85E+03 7.38E+03 9.14E+03 7.72E+03 6.53E+03 6.64E+03 7.29E+03 6.82E+03 7.14E+03 6.64E+03 6.81 E+03 7.30E+03 6.48E+03 6.24E+03 6.65E+03 6.79E+03 Above Log Date AL 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/12/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 Log Time E600 S/N Probe S/N 10:24:00 10:28:00 10:32:00 10:38:00 10:43:00 11:01:00 11:05:00 11:09:00 11:13:00 11:19:00 8:03:00 13:37:00 13:39:00 13:41:00 13:45:00 13:50:00 13:54:00 13:56:00 13:59:00 14:01:00 14:03:00 14:05:00 14:07:00 14:09:00 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9520-0002 9520-02-SC-03-24-0 9520-02-SC-03-25-0 9520-02-SC-03-26-0 9520-02-SC-03-27-0 9520-02-SC-03-28-0 6.59E+03 7.09E+03 7.34E+03 8.93E+03 8.76E+03 7.75E+03 8.29E+03 8.56E+03 1.03E+04 1.01 E+04 6.32E+03 6.86E+03 7.75E+03 9.39E+03 8.42E+03 10/11/2006 10/11/2006 10/11/2006 10/11/2006 10/11/2006 14:11:00 14:15:00 14:16:00 14:17:00 14:18:00 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 9520-0002 SCAN AREA 4 Sample Name 9520-02-SC-04-01-0 9520-02-SC-04-02-0 9520-02-SC-04-03-0 9520-02-SC-04-04-0 9520-02-SC-04-05-0 9520-02-SC-04-06-0 9520-02-SC-04-07-0 9520-02-SC-04-08-0 9520-02-SC-04-09-0 9520-02-SC-04-1 0-0 9520-02-ER-04-1 0-1 9520-02-ER-04-10-2

Background

lccM) 7.31 E+03 7.81 E+03 7.58E+03 7.47E+03 7.60E+03 7.53E+03 7.73E+03 7.39E+03 7.26E+03 7.77E+03 7.77E+03 7.77E+03 Action Level (cpm) 8.53E+03 9.07E+03 8.82E+03 8.70E+03 8.84E+03 8.77E+03 8.99E+03 8.62E+03 8.48E+03 9.03E+03 9.03E+03 9.03E+03 Results fcPM) 6.94E+03 7.45E+03 7.19E+03 7.67E+03 6.91 E+03 7.33E+03 7.74E+03 7.68E+03 7.02E+03 8.28E+03 9.43E+03 8.96E+03 Above Log Date AL 10/10/2006 10/10/2006 10/10/2006 10/10/2006 10/10/2006 10/10/2006 10/10/2006 10/10/2006 10/10/2006 10/10/2006 10/11/2006 10/11/2006 Log Time E600 SIN Probe SIN 9:30:00 9:37:00 9:49.00 10:02:00 10:33:00 10:41:00 10:51:00 12:53:00 13:01:00 13:12:00 8:30:00 8:31:00 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1105 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 1012 AL - Action Level

CENTRAL PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 3 (LABORATORY DATA)

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 174224 SDG: MSR#06-1371 October 23, 2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The samples arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on October 17, 2006 for analysis. Shipping container temperatures were checked, documented, and within specifications. The samples were delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following samples:

Laboratory Identification 174224001 174224002 174224003 174224004 174224005 174224006 174224007 174224008 174224009 174224010 174224011 174224012 174224013 174224014 174224015 174224016 174224017 174224018 174224019 174224020 174224021 174224022 174224023 174224024 174224025 Sample Description 9520-0002-016F 9520-0002-003F 9520-0002-020F 9520-0002-004F 9520-0002-005F 9520-0002-008F 9520-0002-009F 9520-0002-006F 9520-0002-017F 9520-0002-001F 9520-0002-002F 9520-0002-007F 9520-0002-012F 9520-0002M012FS 9520-0002-01OF 9520-0002-014F 9520-0002-013F 9520-0002-01 1F 9520-0002-011 FS 9520-0002-019F 9520-0002-015F 9520-0002-018F 9520-0002-021F 9520-0002-022F 9520-0002-023F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417, 2040 Savage Road (29407)

Phone (843) 556-8171, Fax.243) 766-1178 www.gel.corn

Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL)

Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request Twenty-three soil samples were analyzed for FSSGAM. Two soil samples were analyzed for FSSALL.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax343) 766-1178 www.gel.com

List of current GEL Certifications as of 23 October 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151 CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87 156 (FUJNELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SCO02 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 4

Chain of Custody and Supporting Documentation 5

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major n of "Custody Form Connecticut Yankee Atomic Power Company CNo.

2006-00606 362 Injun Hlollow Road, Fast Hampton. CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only.

Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: -

30D

,4 D'

7D 3

Container D

sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9520-0002-016F 10/9/06 0738 TS G

BP X

9520-0002-003F 10/9/06 0751 TS G

BP X

9520-0002-020F 10/9/06 0802 TS G

BP X

9520-0002-004F 10/9/06 0815 TS G

BP X

9520-0002-005F 10/9/06 0947 TS G

BP-X 9520-0002-008F 10/9/06 0933 TS G

BP X_

9520-0002-009F 10/9/06 1010 TS G

BP X

9520-0002-006F 10/9/06 1025 TS G

BP X

9520-0002-017F 10/9/06 1037 TS G

BP X

9520-0002-001 F 10/9/06 1053 TS G

BP X

9520-0002-002F 10/9/06 1104 TS G

BP X

NOTES: PO #: 002332 MSR #: 06-137/

SSWP# NA 0 LTP QA

[] Radwaste QA IZ Non QA Samples ShippedVia:

E Fed Ex

[] UPS LI Hand El Other Bi7loL-a7io 7ng 7 Bill of Lading #

Internal Container Temp.: T*/'Deg.

.C Custody Sealed?

YFty Nr-1 Custody Seal Intact?

Y K' " N 1...

1) Relinjui By Date/Time
2) eceived

'Date/Time I3)

,;2-r (0.

/o6

<eC B

3) Reli uished By Date/Time 4

teceived By Date/Time

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Chain of Custody Form Connecticut Yankee Atomic Power Company No. 2006-00607.

362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use OnJy Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones C

u Priority:Li30Dg i 4 D.

7 D.E]3D.

  • Container Sample Size-Sample Designation Date Time Media Type

& Type Comment, Preservation Lab Sample ID Code Code Code 9520-0002-007F 10/9/06 Il15 TS G

BP X

9520-0002-012F 10/9/06 1128 TS G

BP X

9520-0002-012FS 10/9/06 1128 TS G

BP

'X 9520-0002-OIOF 10/9/06 1315 TS G

BP.

X 9520-0002-014F 10/9/06 1338 TS G

BP X

9520-0002-013F 10/9/06 1347 TS G

BP X

9520-0002-01 IF 10/9/06 1355 TS G

BP X

9520-0002-011 FS 10/9/06 1355 TS G

BP X

9520-0002-019F 10/9/06 1405 TS G

BP X

9520-0002-015F 10/9/06 1420 TS G

BP X

=

1 9520-0002-018F 10/9/06 1433 TS G

BP X

NOTES: PO #: 002332 MSR #I: 06-1/-71 SSWP#NA 0 LTP QA.10 RadwasteQA Li Non QA

1) Relinqi hedt Date/Time
2) eceived Date/Time

/4-

,0.-/

1,0

3) nqui hed By Date/Time
4) eceived By Date/ ime Samples Shipped Via:

E. Fed Ex El UPS El Hand El Other 77/5"677o 7Mj3(

Bill of Lading #.

Internal Container Temp.: *IL Deg.

C Custody Sealed?

Y [-,(

N I-I Custody Seal Intact?

Y LK" Ni I

Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Chain of Custody Form No. 2006-00608 Connecticut Yankee Atomic Power Company 362 Iljun Hollow Road, East Hlampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning

.' Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories "

2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones V)

Priority: E] 30 D. 2 14 D. M 7 D. [1 3 D.

Container Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code: *_*_._"__

9520-0002-021F 10/11/06 0838 TS G

BP X

9520-0002-022F 10/11/06 0840 TS G

BP.

X 4

4-4-4

+

  • -,----4 4

4 I

I I

I 4-4 4

I

+-I-4 4

I I

I I

4-+

4 I

+

4-4 4

I I

I I

I 4-+

4 I

+

4-4 4

I 4

4 4

4 4-4 4

4 4

4-4 4

I I

4 4-+

4 4

+

4-4 4

4 4

4 4--f 4.4

+

4-~--4.

4 I

I 4

4 4

4-+-------4 4

+

4-4 4

A ______

£ ____

L J......L..............J L

.1.

J....L 4

NOTES: PO #: 002332 MSR #: 06-SSWP# NA E:LTP QA Radwaste QA El Non QA

1) Rel'n bsedy/

Date/Time

2) Received Date/Time
3)

F linquished By Date/Time 4

ecei4ved By

Oate/Time Samples Shipped Via:

0 FedEx.

El us P

[7] Hand Ei Other 7qr 56 -77o 79A, Bill of Lading #

Internal Container Temp.: _2/1 Deg.

C Custody Sealed?

Y [-

N 1 Custody Seal Intact?

Y LW" N Ei

Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00625 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: [1 30 D,-ý4 D. FST 7 D. F-3 D.

C lip~iVT141Container Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab Sample ID Code Code Code 9520-0002-023F 10/12/06 0807 TS G

BP X

NOTES: PO #: 002332 MSR #: 06-/37/

SSWP# NA 0 LTP QA El Radwaste QA Li Non QA Samples Shipped Via:

Z Fed Ex Li UPS Li Hand Di Other 79*;",770 7 0 -

7 Bill of Lading #

Internal Container Temp.: 7_.'ZDeg.

C Custody Sealed?

Y

" NO Custody Seal Intact?

y W-N fi

1) Relinu d B Date/Time
2) ceived By Date/Time
3) Re quishved By Date/Time
4) eceived By Iate/l'ime

Connecticut Yankee Statement of Work for Analytical Lab Services.

CY-ISC-SOW-001 Figure 1. SampleCheck-in List Date/Time Received: 10/i 7/a q13 0 SDG#:

0

~

O

~-

Work Order Number:

\\"h.

V 22.A

-A2."

Shipping Cdhtainer ID:.

feeCoAL. A1ee+/- Chain of Custody#.5ee CoA-, 51

.ee+1

1.

Custody Seals on shipping container intact?...

Yes.c No [ ]

2.

Custody Seals dated and signed?

Yes"[,No [.

3.

Chain-of-Custoly record present?

Yes 4 No []

-4.

Cooler temperature f

,oA_-.

, e

5.

Vermiculite/packing materials is:

Wet [ ] Dry 6.'

Number of samples in shipping container: ____.

7.

Sample holding times exceeded?

Yes [ ] No

8. Samples have:

_k tape

-hazard labels

.__lcustody seals appropriate sample labels

9. Samples are.
  • _X in good condition l leaking broken

-have air bubbles

10.

Were any anomalies identified in sample receipt?

Yes [ ] No4)g" 11..Description of anomalies (include sample numbers):

Sample Custodian/Laboratory:

Date:

A/LLV(,

Telephoned to:

/0)

0 C 4lin rort: "

Client:

\\/4h V' SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM Date Received:

IO/1-- I+6

,7'gS T"7-7'° - 22*"

Zoo6-oýo 6o; 7oo.A -.oCoQ 7'1tl g s o-7 zdo6-&orl-b

-715-67"c?

7S 21)0 2006 -006ol, 2.0o6-o06o%,.

ý53o 6035 145o - 2.-

7006-00637 fi

Data Review Qualifier Definitions 12

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL SD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is

>10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC).

Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417

  • 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fa:L33) 766-1178 www.gel.com

RADIOLOGICAL ANALYSIS 14

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 174224 Method/Analysis Information Product:

Alphaspec Am241, Cm, Solid ALLFSS Analytical Method:

DOE EML HASL-300, Am-05-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

580396 Prep Batch Number:

580008 Dry Soil Prep GL-RAD-A-021 Batch Number: 580006 Sample ID Client ID 174224006 9520-0002-008F 174224021 9520-0002-015F 1201210037 Method Blank (MB) 1201210038 174224006(9520-0002-008F) Sample Duplicate (DUP) 1201210039 174224006(9520-0002-008F) Matrix Spike (MS) 1201210040 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224006 (9520-0002-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

15

Holding Time Allsample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 174224006 (9520-0002-008F) was recounted due to a negative result greater than three times the error.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Alphaspec Pu, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-I 1-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

580398 Prep Batch Number:

580008 Dry Soil Prep GL-RAD-A-021 Batch Number: 580006 Sample ID Client ID 174224006 9520-0002-008F 174224021 9520-0002-015F 1201210045 Method Blank (MB) 1201210046 174224006(9520-0002-008F) Sample Duplicate (DUP) 1201210047 174224006(9520-0002-008F) Matrix Spike (MS) 1201210048 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-0 11 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

16

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224006 (9520-0002-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Pu241, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Pu-11-RC Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

580400 Prep Batch Number:

580008 Dry Soil Prep GL-RAD-A-021 Batch Number: 580006 Sample ID Client ID 174224006 9520-0002-008F 17

174224021 9520-0002-015F 1201210053 Method Blank (MB) 1201210054 174224006(9520-0002-008F) Sample Duplicate (DUP) 1201210055 174224006(9520-0002-008F) Matrix Spike (MS) 1201210056 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Ouality Control (0C) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224006 (9520-0002-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

18

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method:

EML HASL 300, 4.5.2.3 Prep Method:

Dry Soil Prep Analytical Batch Number: 580184 Prep Batch Number:

580004 Sample ID Client ID 174224001 9520-0002-016F 174224002 9520-0002-003F 174224003 9520-0002-020F 174224004 9520-0002-004F 174224005 9520-0002-005F 174224006 9520-0002-008F 174224007 9520-0002-009F 174224008 9520-0002-006F 174224009 9520-0002-017F 174224010 9520-0002-0O1F 174224011 9520-0002-002F 174224012 9520-0002-007F 174224013 9520-0002-012F 174224014 9520-0002-012FS 174224015 9520-0002-OIOF 174224016 9520-0002-014F 174224017 9520-0002-013F 174224018 9520-0002-01IF 174224019 9520-0002-011 FS 174224020 9520-0002-019F 1201209529 Method Blank (MB) 1201209530 174224001(9520-0002-016F) Sample Duplicate (DUP) 1201209531 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information 19

Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224001 (9520-0002-016F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to high peak-width. Bismuth-212 174224012 Cesium-137 174224005 UI Data rejected due to low abundance. Cesium-134 174224002 174224004 174224005 174224007 174224008 174224013 174224014 174224016 174224017 Niobium-94 174224002 UI Data rejected due to no valid peak.

Lead-212 1201209529 20

Method/Analysis Information Product:

Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method:

EML HASL 300, 4..5.2.3 Prep Method:

Dry Soil Prep Analytical Batch Number: 580187 Prep Batch Number:

580006 Sample ID Client ID 174224021 9520-0002-015F 174224022 9520-0002-018F 174224023 9520-0002-021F 174224024 9520-0002-022F 174224025 9520-0002-023F 1201209536 Method Blank (MB) 1201209537 174224021(9520-0002-015F) Sample Duplicate (DUP) 1201209538 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (OC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224021 (9520-0002-015F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information 21

All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments The sample and the duplicate, 1201209537 (9520-0002-015F) and 174224021 (9520-0002-015F), for TI-208 did not meet the relative percent difference requirement, however they do meet the relative error ratio requirement with value of 1.4356.

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to low abundance. Americium-241 174224023 Cesium-134 174224022 174224023 174224024 Method/Analysis Information Product:

GFPC, Sr90, solid-ALL FSS Analytical Method:

EPA 905.0 Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

580488 Prep Batch Number:

580008 Dry Soil Prep GL-RAD-A-021 Batch Number: 580006 Sample ID Client ID 174224006 9520-0002-008F 174224021 9520-0002-015F 1201210298 Method Blank (MB) 1201210299 174224006(9520-0002-008F) Sample Duplicate (DUP) 1201210300 174224006(9520-0002-008F) Matrix Spike (MS) 1201210301 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.

Calibration Information:

Calibration Information 22

All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224006 (9520-0002-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 1201210299 (9520-0002-008F) was recounted due to high MDA.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Tc99, Solid-ALL FSS Analytical Method:

DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 580399 Sample ID Client ID 174224006 9520-0002-008F 174224021 9520-0002-015F 23

1201210049 Method Blank (MB) 1201210050 174224006(9520-0002-008F) Sample Duplicate (DUP) 1201210051 174224006(9520-0002-008F) Matrix Spike (MS) 1201210052 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224006 (9520-0002-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information 24

Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Fe55, Solid-ALL FSS Analytical Method:

DOE RESL Fe-1, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

580395 Prep Batch Number:

580008 Dry Soil Prep GL-RAD-A-021 Batch Number: 580006 Sample ID Client ID 174224006 9520-0002-008F 174224021 9520-0002-015F 1201210033 Method Blank (MB) 1201210034 174224006(9520-0002-008F) Sample Duplicate (DUP) 1201210035 174224006(9520-0002-008F) Matrix Spike (MS) 1201210036 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

QualitV Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224006 (9520-0002-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information 25

All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint Ni63, Solid-ALL FSS Analytical Method:

DOE RESL Ni-1, Modified Prep Method:

Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method:

Dry Soil Prep Analytical Batch Number:

580397 Prep Batch Number:

580008 Dry Soil Prep GL-RAD-A-021 Batch Number: 580006 Sample ID Client ID 174224006 9520-0002-008F 174224021 9520-0002-015F 1201210041 Method Blank (MB) 1201210042 174224021(9520-0002-015F) Sample Duplicate (DUP) 1201210043 174224021(9520-0002-015F) Matrix Spike (MS) 1201210044 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

26

Oualit' Control (00 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224021 (9520-0002-015F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Oualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method:

EPA 906.0 Modified Analytical Batch Number: 580401 Sample ID Client ID 174224006 9520-0002-008F 174224021 9520-0002-015F 1201210057 Method Blank (MB) 1201210058 174224006(9520-0002-008F) Sample Duplicate (DUP) 1201210059 174224006(9520-0002-008F) Matrix Spike (MS) 1201210060 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 13.

27

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (Q0 Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224006 (9520-0002-008F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1201210058 (9520-0002-008F), 174224006 (9520-0002-008F) and 174224021 (9520-0002-015F) were recounted due to high MDAs.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product:

Liquid Scint C14, Solid AII,FSS Analytical Method:

EPA EERF C-01 Modified Analytical Batch Number: 580402 Sample ID Client ID 174224006 9520-0002-008F 28

174224021 9520-0002-015F 1201210061 Method Blank (MB) 1201210062 174224021(9520-0002-015F) Sample Duplicate (DUP) 1201210063 174224021(9520-0002-015F) Matrix Spike (MS) 1201210064 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174224021 (9520-0002-015F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

29

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer/Date:

JAAAAJLL)(V' 30

SAMPLE DATA

SUMMARY

31

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1371 GEL Work Order: 174224 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 32

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis w

i Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

9520-0002-016F Project:

YANKO01204 Sample ID:

174224001 Client ID:

YANKOO Matrix:

TS Vol. Recv.:

Collect Date:

09-OCT-06 Receive Date:

17-OCT-06 Collector:

Client Moisture:

4.86%

Parameter Qualifier Result " Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.656 Americium-241 U

-0.0484 Bismuth-212 0.740 Bismuth-214 0.521 Cesium-134 U

0.0423 Cesium-137 0.053 Cobalt-60 U

0.00102 Europium-152 U -0.00774 Europium-154 U

-0.0447 Europium-155 U

0.035 Lead-212 0.730 Lead-214 0.572 Manganese-54 U

0.002 Niobium-94 U

0.00326 Potassium-40 10.7 Radium-226 0.521 Silver-108m U -0.00426 Thallium-208 0.249

+1-0.1 49-

+/-0.120

+1-0.207 F/-0.0704 F/-0.0387 F/-0.0324 FI-0.0188

+I-0.046 1

+/-0.0569

+I-0.0562

+/-0.0581I

+/-0.0735 1-/-0.0188

+/-0.01 61

+/-1-0.758

+/-0.0704

+/-0.01 57

+/-0.0433 0.051 0.0938 0.117 0.0282 0.020 0.0153 0.0164 0.0413 0.0453 0.0541 0.025 0.0321 0.0165 0.0145 0.130 0.0282 0.0136 0.0129

+/-0.149

+/-0.120

+/-0.207

+/-0.0704

+/-0.0387

+/-0.0324

+/-0.0188

+/-0.0461

+/-0.0569

+/-0.0562

+/-0.0581

+/-0.0735

+/-0.0188

+/-0.0161

+/-0.758

+/-0.0704

+/-0.0157

+/-0.0433 0.111 0.195 0.252 0.060 0.0425 0.0327 0.0359 0.0871 0.0994 0.113 0.0523 0.0674 0.0353 0.031 0.293 0.060 0.0289 0.0278 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1057 580184 1

The following Prep Methods were performed Method _

Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 33

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-016F Project:

YANK01204 Sample ID:

174224001 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-003F 174224002 TS 09-OCT-06 17-OCT-06 Client 7.79%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 1.15 U

0.0214 0.798 0.975 UL 0.00 U

0.0316 U

0.00195 U

-0.0409 U

-0.0259 U

0.114 1.19 1.03 U

0.0228 UI 0.00 16.9 0.975 U

-0.0113 0.345

+/-0.192

+/-0.0897

+/-0.308

+/-0.113

+/-0.042

+/-0.0243

+/-0.0229

+/-0.0572

+/-0.0666

+/-0.114

+/-0.0781

+/-0.104

+/-0.0241

+/-0.0416

+/-1.06

.+/-0.113

+/-0.020

+/-0.0494 0.0672 0.0825 0.140 0.036 0.0254 0.0201 0.0191 0.0482 0.0528 0.0608 0.0329 0.037 0.0221 0.0182 0.175 0.036 0.0166 0.0182

+/-0.192

+/-0.0897

+/-0.308

+/-0.113

+/-0.042

+/-0.0243

+/-0.0229

+/-0.0572

+/-0.0666

+/-0.114

+/-0.0781

+/-0.104

+/-0.0241

+/-0.0416

+/-1.06

+/-0.113

+/-0.020

+/-0.0494 0.144 0.170 0.298 0.0761 0.0536 0.0425 0.0417 0.101 0.115 0.126 0.0682 0.0774 0.0467 0.0385 0.384 0.0761 0.035 0.0386 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1101 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-003F Proiect:

YANK01204 Sample ID:

174224002 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

36

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-020F 174224003 TS 09-OCT-06 17-OCT-06 Client 5.48%

Project:

Client ID:

Vol. Recv.:

YANK0 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228.

0.906

+/-0.257 Americium-241 U

0.00899

+/-0.0408 Bismuth-212 U

0.346

+/-0.505 Bismuth-214 0.588

+/-0.118 Cesium-134 U

0.0432

+/-0.0547 Cesium-137 U

0.0619

+/-0.0517 Cobalt-60 U -0.00849

+/-0.0374 Europium-152 U

-0.0343

+/-0.0771 Europium-154 U

-0.0334

+/-0.099 Europium-i 55.

U -0.00124

+/-0.0668 Lead-212 0.645

+/-0.091 Lead-214 0.627

+/-0.126 Manganese-54 U

0.0354

+/-0.0353 Niobium-94 U

0.0287

+/-0.0306 Potassium-40 12.0

+/-1.08 Radium-226 0.588

+/-0.118 Silver-108m U

0.00743

+/-0.0239 Thallium-208 0.222

+/-0.0588 0.0872 0.0372 0.182 0.0471 0.0356 0.0293 0.0306 0.0641 0.0804 0.0575 0.0543 0.0485 0.0322 0.0282 0.234 0.0471 0.0221 0.0279

+/-0.257

+/-0.0408

+/-0.505

+/-0.118

+/-0.0547

+/-0.0517

+/-0.0374

+/-0.0771

+/-0.099

+/-0.0668

+/-0.091

+/-0.126

+/-0.0353

+/-0.0306

+/-1.08

+/-0.118

+/-0.0239

+/-0.0588 0.190 0.077 0.395 0.101 0.0758 0.0624 0.0671 0.135 0.177 0.120 0.112 0.102 0.0684 0.0598 0.527 0.101 0.0469 0.0594 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1225 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-020F Proiect:

YANK01204 Sample ID:

174224003 Client ID:

YANKOOI Pa tVol.

Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-004F 174224004 TS 09-OCT-06 17-OCT-06 Client 5.76%

Proiect:

YANK01204 Client ID:

YANKOOl Vol. Recv.:

Parameter C

Rad Gamma Spec Analysis

)ualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.885

+/-0.223 Americium-241 U

0.0457

+/-0.0472 Bismuth-212 U

0.453

+/-0.315 Bismuth-214 0.592

+/-0.130 Cesium-134 UI 0.00

+/-0.0631 Cesium-137 0.113

+1-0.0551 Cobalt-60 U

0.00471

+/-0.0431 Europium-152 U

-0.0789

+/-0.111 Europium-154 U

-0.0433

+/-0.139 Europium-155 U

0.0401

+/-0.0704 Lead-212 0.739

+/-0.101 Lead-214 0.702

+/-0.146 Manganese-54 U

0.00374

+/-0.0374 Niobium-94 U

0.00532

+/-0.0328 Potassium-40 11.0

+/-1.24 Radium-226 0.592

+/-0.130 Silver-108m U

-0.0374

+/-0.029 Thallium-208 0.204

+/-0.0904 0.100 0.0392 0.296 0.0529 0.0417 0.0282 0.0365 0.0667 0.112 0.0635 0.0372 0.0493 0.0327 0.0291 0.325 0.0529 0.0221 0.0271

+/-0.223

+/-0.0472

+/-0.315

+/-0.130

+/-0.0631

+1-0.0551

+/-0.0431

+/-0.111

+/-0.139

+/-0.0704

+/-0.101

+/-0.146

+/-0.0374

+/-0.0328

+/-1.24

+/-0.130

+/-0.029

+/-0.0904 0.201 0.0784 0.592 0.106 0.0833 0.0563 0.0729 0.133 0.224 0.127 0.0744 0.0986 0.0653 0.0582 0.650 0.106 0.0442 0.0542 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1244 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMBI 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-004F Project:

YANK01204 Sample ID:

174224004 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank, BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R. Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-005F 174224005 TS 09-OCT-06 17-OCT-06 Client 3.28%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.586

+/-0.145 Americium-241 U

-0.0266

+/-0.0889 Bismuth-212 0.391

+/-0.229 Bismuth-214 0.498

+/-0.0639 Cesium-134 UI 0.00

+/-0.0308 Cesium-137 UI 0.00

+/-0.0483 Cobalt-60 U

0.0103.

+/-0.0191 Europium-152 U 0.000548

+/-0.0428 Europium-154 U

-0.0126

+/-0.0535 Europium-155 U

0.0307

+/-0.0437 Lead-212 0.679

+/-0.0518 Lead-214 0.560

+/-0.0799 Manganese-54 U

0.0146

+/-0.0172 Niobium-94 U

0.00268

+/-0.0155 Potassium-40 10.5

+/-0.750 Radium-226 0.498

+/-0.0639 Silver-108m U

0.0072

+/-0.0154 Thallium-208 0.186

+/-0.0432 0.0501 0.0712 0.114 0.0278 0.0187 0.0128 0.0171 0.0366 0.0444 0.0421 0.0209 0.0245 0.0155 0.0134 0.135 0.0278 0.0127 0.0135

+/-0.145

+/-0.0889

+/-0.229

+/-0.0639

+/-0.0308

+/-0.0483

+/-0.0191

+/-0.0428

+/-0.0535

+/-0.0437

+/-0.0518

+/-0.0799

+/-0.0172

+/-0.0155

+/-0.750

+/-0.0639

+/-0.0154

+/-0.0432 0.108 0.147 0.242 0.0588 0.0395 0.0274 0.037 0.0768 0.0968 0.087 0.0435 0.0516 0.0331 0.0285 0.300 0.0588 0.0268 0.0287 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1258 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 41 A

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-005F Project:

YANK01204 Sample ID:

174224005 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-008F 174224006 TS 09-OCT-06 17-OCT-06 Client 8.78%

Project:

YANK01204 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -

Curium-242 U

Curium-243/244 U

Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

Plutonium-239/240 U

Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

0.00901

+/-0.0461 0.0494 +/-0.0461 0.00

+/-0.0812 0.00 +/-0.0812 0.00

+/-0.0764 0.00 +/-0.0764 0.00905

+/-0.086 0.0672

+/-0.086

-0.0532

+/-0.0721 0.0879 +/-0.0723

-4.06

+/-7.84 6.76

+/-7.84 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM &ALL FSS 226 Ingrowth Waived Actinium-228 1.02 Americium-241 U

0.00802 Bismuth-212 0.677 Bismuth-214 0.675 Cesium-134 U

0.0465 Cesium-137 0.0801 Cobalt-60 U -0.00558 Europium-152 U

-0.0291 Europium-154 U

0.0675 Europium-155 U

0.0469 Lead-212 0.855 Lead-214 0.785 Manganese-54 U

0.0191 Niobium-94 U

0.00807 Potassium-40 12.3 Radium-226 0.675 Silver-108m U -0.00392 Thallium-208 0.312 Rad Gas Flow Proportional Counting GFPC, Sr90, solid-ALL FSS Strontium-90 U

0.0274 Rad Liquid Scintillation Analysis

+/-0.218 4/-0.03 8 3

+/-0.537

+/-0.121

+/-0.0461

+/-0.0347

+/-0.0307

+/-0.0742

+/-0.091

+/-0.0657

+/-0.0857

+/-0.110 F/-0.0302 F/-0.0284

+/-1.22

+/-0.121

+/-0.0242

+/-0.0585

+/-0.0243 0.0722 0.0354 0.185 0.0505 0.0323 0.0273 0.0252 0.0643 0.0851 0.0606 0.0351 0.0422 0.027 0.0247 0.228 0.0505 0.0209 0.023

+/-0.218

+/-0.0383

+/-0.537

+/-0.121

+/-0.0461

+/-0.0347

+/-0.0307

+/-0.0742

+/-0.091

+/-0.0657

+/-0.0857

+/-0.110

+/-0.0302

+/-0.0284

+/-1.22

+/-0.121

+/-0.0242

+/-0.0585 0.204 0.112 0.106 0.211 0.252 14.2 0.163 0.0734 0.405 0.109 0.0699 0.0591 0.0574 0.137 0.189 0.126 0.0739 0.0902 0.0588 0.0533 0.526 0.109 0.0451 0.0501 0.0402 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MXA M

MXA I

MXA I

10/23/06 1039 580396 1

10/20/06 0813 580398 2

10/21/06 1632 580400 3

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1259 580184 4

KSD1 10/20/06 1940 580488 5

0.019 +/-0.0243 43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis T

i Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

9520-0002-008F 174224006 Project:

YANKO01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U

-0.10 Liquid Scint C14, Solid AII,FSS Carbon-14 U

-0.0573 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

2.10 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-4.05 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.148 Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-2.79 2.35

+/-2.79 4.82

+/-0.109 0.0931

+/-0.109 0.191

+/-28.7 20.9

+/-28.7 43.9

+/-8.06 6.95

+/-8.06 14.6

+/-0.198 0.161

+/-0.198 0.334 pCi/g pCi/g pCi/g pCi/g pCi/g DFAI 10/23/06 1236 580401 6

AXD2 10/21/06 1450 580402 8

MXPI 10/23/06 0015 580395 9

MXP1 10/22/06 2003 580397 10 KXR1 10/24/06 1317 580399 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description 1

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-I 1-RC Modified 3

DOE EML HASL-300, Pu-11 -RC Modified 4

EML HASL 300,4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA 906.0 Modified 8

EPA EERF C-01 Modified 9

DOE RESL Fe-I, Modified 10 DOE RESL Ni-I, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery%

Acceptable Limits Americium-243 Plutonium-242 Plutonium-241 Strontium-90 Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FE GFPC, Sr90, solid-ALL FSS 81 93 84 87 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gelhcom Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-008F Project:

YANK01204 Sample ID:

174224006 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery GFPC, Sr9O, solid-ALL FSS 87 (25%-125%)

Iron-55 Liquid Scint Fe55, Solid-ALL FS 63 (15%-125%)

Nickel-63 Liquid Scint Ni63, Solid-ALL FS 87 (25%-125%)

Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 87 (25%-125%)

Technetium-99 Liquid Scint Tc99, Solid-ALL FS 84 (15%-125%)

Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 84 (15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-009F 174224007 TS 09-OCT-06 17-OCT-06 Client 8.34%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mt(

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.840

+/-0.110 Americium-241 U

-0.073

+/-0.105 Bismuth-212 0.536

+/-0.181 Bismuth-214 0.611

+/-0.0743 Cesium-134 UI 0.00

+/-0.0281 Cesium-137 0.0834

+/-0.0244 Cobalt-60 U -0.00486

+/-0.0144 Europium-152 U

-0.0103

+/-0.0393 Europium-154 U

-0.012

+/-0.0484 Europium-155 U

0.058

+/-0.0643 Lead-212 0.832

+/-0.0505 Lead-214 0.804

+/-0.0676 Manganese-54 U -0.00243

+/-0.0176 Niobium-94 U

0.0208

+/-0.0127 Potassium-40 12.5

+/-0.669 Radium-226 0.611

+/-0.0743 Silver-108m U

0.00572

+/-0.0131 Thallium-208 0.261

+/-0.0305 0.0417 0.0789 0.0985 0.0254 0.0163 0.0134 0.012 0.0343 0.0409 0.0446 0.0224 0.0253 0.013 0.0127 0.109 0.0254 0.0116 0.0128

+/-0.110

+/-0.105

+/-0.181

+/-0.0743

+/-0.0281

+/-0.0244

+/-0.0144

+/-0.0393

+/-0.0484

+/-0.0643

+/-0.0505

+/-0.0676

+/-0.0176

+/-0.0127

+/-0.669

+/-0.0743

+/-0.0131

+/-0.0305 0.0883 0.162 0.207 0.053 0.034 0.028 0.0258 0.0713 0.087 0.0916 0.046 0.0525 0.0272 0.0265 0.237 0.053 0.0241 0.0267 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1306 580184. 1 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

  • g A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-009F Project:

YANK01204 Sample ID:

174224007 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton. Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-006F 174224008 TS 09-OCT-06 17-OCT-06 Client 5.61%

Project:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.428 U

0.00445 0.522 0.441 U1 0.00 0.053 U

0.0111 U

0.0327 U

-0.0039 U -0.00205 0.544 0.425 U

0.0171 U

0.00344 11.5 0.441 U -0.00111 0.165

+/-0.128

+/-0.0695

+/-0.186

+/-0.0666

+/-0.0224

+/-0.0324

+/-0.0152

+/-0.0445

+/-0.0476

+/-0.050

+/-0.0517

+/-0.0752

+/-0.0174

+/-0.0139

+/-0.739

+/-0.0666

+/-0.0144

+/-0.0315 0.0429 0.060 0.107 0.0259 0.0178 0.0122 0.014 0.0378 0.0395 0.046 0.0244 0.0263 0.0149 0.0126 0.110 0.0259 0.0127 0.0146

+/-0.128

+/-0.0695

+/-0.186

+/-0.0666

+/-0.0224

+/-0.0324

+/-0.0152

+/-0.0445

+/-0.0476

+/-0.050

+/-0.0517

+/-0.0752

+/-0.0174

+/-0.0139

+/-0.739

+/-0.0666

+/-0.0144

+/-0.0315 0.0936 0.124 0.230 0.0552 0.0379 0.0264 0.0308 0.0796 0.0868 0.0956 0.0508 0.0554 0.0318 0.027 0.248 0.0552 0.0269 0.031 pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCilg pCi/g pCi/g pCi/g MJH1 10/23/06 1307 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description 1

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-006F Proiect:

YANK01204 Sample ID:

174224008 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-017F 174224009 TS 09-OCT-06 17-OCT-06 Client 3.13%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.807

+/-0.242 Americium-241 U

-0.0127

+/-0.0439 "Bismuth-212 0.452

+/-0.407 Bismuth-214 0.664

+/-0.111 Cesium-134 U

0.0329

+/-0.0352 Cesium-137 U

0.0422

+/-0.0375 Cobalt-60 U -0.00349

+/-0.0369 Europium-152 U

-0.0308

+/-0.072 Europium-154 U

-0.02

+/-0.101 Europium-155 U

0.0387

+/-0.0863 Lead-212 0.649

+/-0.0898 Lead-214 0.646

+/-0.111 Manganese-54 U

0.016

+/-0.0335 Niobium-94 U

0.0104

+/-0.0316 Potassium-40 10.9

+/-1.03 Radium-226 0.664

+/-0.111 Silver-108m U -0.00279

+/-0.0246 Thallium-208 0.269

+/-0.0571 0.095 0.036 0.204 0.0468 0.0324 0.0295 0.0264 0.060 0.0831 0.0573 0.0521 0.0488 0.0294 0.0278 0.200 0.0468 0.022 0.0235

+/-0.242

+/-0.0439

+/-0.407

+/-0.111

+/-0.0352

+/-0.0375

+/-0.0369

+/-0.072

+/-0.101

+/-0.0863

+/-0.0898

+/-0.111

+/-0.0335

+/-0.0316

+/-1.03

+/-0.111

+/-0.0246

+/-0.0571 0.206 0.0746 0.439 0.100 0.0692 0.0629 0.0585 0.127 0.182 0.119 0.108 0.103 0.0629 0.0591 0.459 0.100 0.0468 0.0504 pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCilg pCi/g MJH1 10/23/06 1427 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-017F Proiect:

YANK01204 Sample ID:

174224009 Client ID:

YANKOOl Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low

,C Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample

.H Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-001F 174224010 TS 09-OCT-06 17-OCT-06 Client 3.58%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived

.Actinium-228 0.850

+/-0.240 Americium-241 U

0.0152

+/-0.0475 Bismuth-212 U

0.495

+/-0.330 Bismuth-214 0.708

+/-0.158 Cesium-134 U

0.0361

+/-0.0592 Cesium-137 U

0.0386

+/-0.0553 Cobalt-60 U

0.0104

+/-0.0336 Europium-152 U

0.0404

+/-0.0883 Europium-154 U

0.0452

+/-0.131 Europium-155 U

0.0253

+/-0.075 Lead-212 0.730

+/-0.102 Lead-214 0.616

+/-0.125 Manganese-54 U

-0.0293

+/-0.0418 Niobium-94 U

0.00228

+/-0.0309 Potassium-40 11.4

+/-1.23 Radium-226 0.708

+/-0.158 Silver-108m U

0.00402

+/-0.0285 Thallium-208 0.219

+/-0.0701 0.108 0.0384 0.250 0.0489 0.0379 0.0279 0.0296 0.0668 0.114 0.0623 0.0375 0.0491 0.0274 0.0273 0.191 0.0489 0.0249 0.0256

+/-0.240

+/-0.0475

+/-0.330

+/-0.158

+/-0.0592

+/-0.0553

+/-0.0336

+/-0.0883

+/-0.131

+/-0.075

+/-0.102

+/-0.125

+/-0.0418

+1-0.0309

+/-1.23

+/-0.158

+/-0.0285

+/-0.0701 0.215 0.0767 0.499 0.0977 0.0758 0.0557 0.0592 0.134 0.228 0.125 0.075 0.0982 0.0549 0.0545 0.382 0.0977 0.0498 0.0512 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1453 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 24, 2006 Client Sample ID:

Sample ID:

9520-0002-001F 174224010 Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or* more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.geLcom Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton. Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 24, 2006 Client Sample ID:

9520-0002-002F Project:

YANK01204 Sample ID:

174224011 Client ID:

YANK00I Matrix:

TS Vol. Recv.:

Collect Date:

09-OCT-06 Receive Date:

17-OCT-06 Collector:

Client Moisture:

11.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtt Rad Gamma Spec Analysis Gamnma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.596

+/-0.142 Americium-241 U

-0,0475

+/-0.0993 Bismuth-212 0.553

+/-0.215 Bismuth-214 0.445

+/-0.0684 Cesium-134 U

0.0112

+/-0.0224 Cesium-137 0.0953

+/-0.0395 Cobalt-60 U

0.0103

+/-0.0192 Europium-152 U

0.0402

+/-0.052

.Europium-154 U 0.000834

+/-0.077 Europium-155 U

0.0343

+/-0.0529 Lead-212 0.577

+/-0.0577 Lead-214 0.427

+/-0.0859 Manganese-54 U

0.0316

+/-0.0225 Niobium-94 U-0.000249

+/-0.0177 Potassium-40 9.03

+/-0.878 Radium-226 0.445

+/-0.0684 Silver-108m U

0.00371

+/-0.0168 Thallium-208 0.184

+/-0.0408 0.0526 0.0894 0.131 0.0285 0.0205 0.0182 0.0179 0.0487 0.0575 0.0536 0.0273 0.0298 0.0165 0.0155 0.156 0.0285 0.0141 0.0164

+/-0.142

+/-0,0993

+/-0.215

+/-0.0684

+/-0.0224

+/-0.0395

+/-0.0192

+/-0.052

+/-0.077

+/-0.0529

+/-0.0577

+/-0.0859

+/-0.0225

+/-0.0177

+/-0.878

+/-0.0684

+/-0.0168

+/-0.0408 0.118 0.187 0.287 0.0623 0.0446 0.0396 0.0408 0.104 0.128 0.112 0.0574 0.0639 0.0364 0.0338 0.362 0.0623 0.0304 0.0356 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1506 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-002F Project:

YANK01204 Sample ID:

174224011 Client ID:

YANKOO Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low

,C Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton. Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

Parameter Qualifier Result U'

Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.712

  • Americium-241 U

0.017 Bismuth-212 UI 0.508 Bismuth-214 0.706 Cesium-134 U

0.042 Cesium-137 0.116 Cobalt-60 U

0.0184 Europium-152 U

0.00172 Europium-154 U

-0.0194 Europium-155 U

0.0486 Lead-212 0.755 Lead-214 0.634 Manganese-54 U

-0.0102 Niobium-94 U

-0.0022 Potassium-40 10.0 Radium-226 0.706 Silver-108m U

0.0107 Thallium-208 0.259 9520-0002-007F 174224012 TS 09-OCT-06 17-OCT-06 Client 16.9%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 ncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd

+/-0.189

+/-0.0337

+/-0.366

+/-0.123

+/-0.028

+/-0.0416

+/-0.024

+/-0.0619

+/-0.0733

+/-0.0825

+/-0.0749

+/-0.113

+/-0.0244

+/-0.0234

+/-1.04

+/-0.123

+/-0.022

+/-0.0535 0.0909 0.0326 0.176 0.0416 0.0277 0.0201 0.0267 0.0564 0.0601 0.0478 0.0274 0.0414 0.0194 0.0199 0.235 0.0416 0.0204 0.0215

+/-0.189

+/-0.0337

+/-0.366

+/-0.123

+/-0.028

+/-0.0416

+/-0.024

+/-0.0619

+/-0.0733

+/-0.0825

+/-0.0749

+/-0.113

+/-0.0244

+/-0.0234

+/-1.04

+/-0.123

+/-0.022

+/-0.0535 0.198 0.0675 0.383 0.0898 0.060 0.044 0.0595 0.120 0.137 0.100 0.058 0.0878 0.043 0.0432 0.531 0.0898 0.0436 0.0465 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1507 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407- (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-007F Project:

YANK01204 Sample ID:

174224012 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtu Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd

Contact:

Project:

East Hampton, Connecticut 06424 Mr. Jack McCarthy Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-012F 174224013 TS 09-OCT-06 17-OCT-06 Client 7.67%

Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.572

+/-0.141 Americium-241 U

0.0415

+/-0.108 Bismuth-212 0.341

+/-0.204 Bismuth-214 0.444

+/-0.0719 Cesium-134 UI 0.00

+/-0.0316 Cesium-137 0.330

+/-0.0357 Cobalt-60 U

0.00219

+/-0.0159 Europium-152 U

-0.0182

+/-0.0439 Europium-I 54 U

-0.024

+/-0.0518 Europium-155 U

0.0138

+/-0.0551 Lead-212 0.652

+/-0.0534 Lead-214 0.530

+/-0.0743 Manganese-54 U -0.00187

+/-0.0168 Niobium-94 U

-0.0032

+/-0.0161 Potassium-40 14.4

+/-0.799 Radium-226 0.444

+/-0.0719 Silver-108m 0.0281

+/-0.0208 Thallium-208 0.240

+/-0.0408 0.051 0.0879 0.111 0.0284 0.0192 0.0158 0.0139 0.0384 0.0428 0.0514 0.0246 0.0279 0.0144 0.014 0.123 0.0284 0.0123 0.015

+/-0.141

+/-0.108

+/-0.204

+/-0.0719

+/-0.0316

+/-0.0357

+/-0.0159

+/-0.0439

+/-0.0518

+/-0.0551

+/-0.0534

+/-0.0743

+/-0.0168

+/-0.0161

+/-0.799

+/-0.0719

+/-0.0208

+/-0.0408 0.109 0.182 0.237 0.0599 0.0406 0.0335 0.0305 0.0807 0.0931 0.106 0.0511 0.0585 0.0308 0.0297 0.273 0.0599 0.0261 0.0317 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1534 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis

'Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-01 2F Project:

YANK01204 Sample ID:

174224013 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mte Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-012FS 174224014 TS 09-OCT-06 17-OCT-06 Client 7.64%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.639

+/-0.169 Americium-241 U

-0.0317

+/-0.072 Bismuth-212 0.385

+/-0.257 Bismuth-214 0.466

+/-0.112 Cesium-134 U1 0.00

+/-0.0243 Cesium-137 0.350

+/-0.0443 Cobalt-60 U

-0.016

+/-0.0199 Europium-152 U

-0.0154

+/-0.048 Europium-154 U

0.00846

+/-0.0537 Europium-155 U

0.0527

+/-0.0592 Lead-212 0.710

+/-0.0607 Lead-214 0.534

+/-0.0867 Manganese-54 U 0.000606

+/-0.019 Niobium-94 U

0.0156

+/-0.0162 Potassium-40 12.8

+/-0.881 Radium-226 0.466

+/-0.112 Silver-108m U

0.00742

+/-0.0165 Thallium-208 0.232

+/-0.0384 0.0421 0.0658 0.113 0.0303 0.0192 0.0185 0.0148 0.0418 0.0456 0.0554 0.0246 0.0307 0.0166 0.0153 0.144 0.0303 0.0148 0.0163

+/-0.169

+/-0.072

+/-0.257

+/-0.112

+/-0.0243

+/-0.0443

+/-0.0199

+/-0.048

+/-0.0537

+/-0.0592

+/-0.0607

+/-0.0867

+/-0.019

+/-0.0162

+/-0.881

+/-0.112

+/-0.0165

+/-0.0384 0.0929 0.136 0.244 0.0643 0.0408 0.0392 0.0327 0.0881 0.0999 0.115 0.0515 0.0647 0.0354 0.0325 0.321 0.0643 0.0314 0.0346 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/23/06 1535 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-012FS Project:

YANK01204 Sample ID:

174224014 Client ID:

YANKOOI Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank 3BD Results are either below the MDC or tracer recovery is low

'C Analyte has been confirmed by GC/MS analysis Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

.UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-01 OF 174224015 TS 09-OCT-06 17-OCT-06 Client 6.2%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived

  • Actinium-228 0.806

+/-0.237 Americium-241 U

0.0289

+/-0.0408 Bismuth-212 U

0.436

+/-0.325 Bismuth-214 0.577

+/-0.133 Cesium-134 U

0.0203

+/-0.0334 Cesium-137 U

0.0416

+/-0.0366 Cobalt-60 U -0.00187

+/-0.034 Europium-152 U -0.00333

+/-0.0733 Europium-154 U

0.0337

+/-0.102 Europium-155 U

0.0473

+/-0.0692 Lead-212 0.653

+/-0.0885 Lead-214 0.566

+/-0.115 Manganese-54 U

0.0119

+/-0.0384 Niobium-94 U

-0.0138

+/-0.0298 Potassium-40 11.9

+/-1.21 Radium-226 0.577

+/-0.133 Silver-108m U

0.0137

+/-0.0256 Thallium-208 0.261

+/-0.0682 0.101 0.0376 0.210 0.0467 0.0361 0.0341 0.0283 0.0623 0.0893 0.0613 0.0492 0.050 0.0292 0.0244 0.220 0.0467 0.0238 0.0259

+/-0.237

+/-0.0408

+/-0.325

+1-0.133

+/-0.0334

+/-0.0366

+/-0.034

+/-0.0733

+/-0.102

+/-0.0692

+/-0.0885

+/-0.115

+/-0.0384

+/-0.0298

+/-1.21

+/-0.133

+/-0.0256

+/-0.0682 0.218 0.0779 0.452 0.100 0.0769 0.0723 0.0627 0.132 0.195 0.127 0.102 0.105 0.0627 0.0523 0.502 0.100 0.0504 0.0556 pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1636 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-OIOF Project:

YANK01204 Sample ID:

174224015 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank

'BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-014F 174224016 TS 09-OCT-06 17-OCT-06 Client 8.04%

Proiect:

Client ID:

Vol. Recv.:

YANKO 1204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.503

+/-0.121 Americium-241 U

0.00401

+/-0.0983 Bismuth-212 0.353

+/-0.187 Bismuth-214 0.372

+/-0.0718 Cesium-134 UI 0.00

+/-0.022 Cesium-137 0.0968

+/-0.0282 Cobalt-60 U

0.00121

+/-0.0177 Europium-152 U

-0.0129

+/-0.0385 Europium-154 U

-0.0158

+/-0.0456 Europium-155 U

0.0505

+/-0.0505 Lead-212 0.545

+/-0.046 Lead-214 0.478

+/-0.0792 Manganese-54 U-0.000989

+/-0.0161 NiobiumL94 U -0.00587

+/-0.0143 Potassium-40 8.79

+/-0.682 Radium-226 0.372

+/-0.0718 Silver-108m U -0.00393

+/-0.0138 Thallium-208 0.192

+/-0.0327 0.0443 0.0771 0.0969 0.0252 0.0156 0.0126 0.0153 0.0336 0.038 0.0478 0.0206 0.025 0.0138 0.0122 0.121 0.0252 0.0118 0.0131

+/-0.121

+/-0.0983

+/-0.187

+/-0.0718

+/-0.022

+/-0.0282

+/-0.0177

+/-0.0385

+/-0.0456

+/-0.0505

+/-0.046

+/-0.0792

+/-0.0161

+/-0.0143

+/-0.682

+/-0.0718

+/-0.0138

+/-0.0327 0.0951 0.160 0.207 0.0532 0.0332 0.0268 0.033 0.0706 0.0826 0.0987 0.0428 0.0526 0.0293 0.0259 0.266 0.0532 0.0249 0.0277 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1833 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-014F Project:

YANK01204 Sample ID:

174224016 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

65

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-013F 174224017 TS 09-OCT-06 17-OCT-06 Client 16.7%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MtU Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.730

+/-0.126 Americium-241 U

-0.029

+/-0.0586 Bismuth-212 0.522

+/-0.218 Bismuth-214 0.582

+/-0.0711 Cesium-134 UI 0.00

+/-0.0278 Cesium-137 0.203

+/-0.036 Cobalt-60 0.0472

+/-0.0221 Europium-152 U

-0.043

+/-0.0405 Europium-154 U

0.012

+/-0.049 Europium-155 U

0.0235

+/-0.0505 Lead-212 0.727

+/-0.0508 Lead-214 0.582

+/-0.0746 Manganese-54 U

0.021

+/-0.0252 Niobium-94 U

0.00768

+/-0.0138 Potassium-40 12.4

+/-0.663 Radium-226 0.582

+/-0.0711 Silver-108m U -0.00125

+/-0.0132 Thallium-208 0.235

+/-0.0332 0.0412 0.0533 0.101 0.0243 0.0163 0.0128 0.0118 0.0339 0.0417 0.046 0.020 0.0261 0.0137 0.0126 0.0915 0.0243 0.0114 0.0132

+/-0.126

+/-0.0586

+/-0.218

+/-0.0711

+/-0.0278

+/-0.036

+/-0.0221

+/-0.0405

+/-0.049

+/-0.0505

+/-0.0508

+/-0.0746

+/-0.0252

+/-0.0138

+/-0.663

+/-0.0711

+/-0.0132

+/-0.0332 0.0882 0.110 0.213 0.0512 0.0344 0.027 0.0259 0.0709 0.0893 0.0945 0.0414 0.0545 0.029 0.0264 0.205 0.0512 0.0239 0.0279 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1834 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1127 580004 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-013F Project:

YANK01204 Sample ID:

174224017 ClientID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank

,BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more

.R Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

1UI Gamma'Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel com Certificate of Analysis Company :

Connecticut Yankee Atomic Power Address :

362 Iniun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-01 IF 174224018 TS 09-OCT-06 17-OCT-06 Client 8.65%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.632 U

0.0295 U

0.409 0.462 U

0.0581 0.0908 U

0.0282 U

-0.0458 U

0.0228 U

0.0319 0.711 0.557 U

0.00341 U

0.00939 11.1 0.462 U

-0.0147 0.240

+/-0.230

+/-0.0488

+/-0.332

+/-0.125

+/-0.0394

+/-0.0712

+/-0.0376

+/-0.119

+/-0.142

+/-0.066

+/-0.0965

+/-0.126

+/-0.0382

+/-0.0327

+/-1.34

+/-0.125

+/-0.0284

+/-0.0636 0.0998 0.0357 0.207 0.0436 0.0368 0.0288 0.0321 0.0672 0.105 0.060 0.0337 0.0465 0.0289 0.0282 0.241 0.0436 0.0236 0.0268

+/-0.230

+/-0.0488

+/-0.332

+/-0.125

+/-0.0394

+/-0.0712

+/-0.0376

+/-0.119

+/-0.142

+/-0.066

+/-0.0965

+/-0.126

+/-0.0382

+/-0.0327

+/-1.34

+/-0.125

+/-0.0284

+/-0.0636 0.200 0.0714 0.415 0.0872 0.0735 0.0575 0.0641 0.134 0.210 0.120 0.0673 0.0929 0.0578 0.0564 0.482 0.0872 0.0472 0.0536 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g MJH1 10/23/06 1850 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1128 580004 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-01IF Project:

YANK01204 Sample ID:

174224018 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank

.BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded

.J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

.UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-01IFS 174224019 TS 09-OCT-06 17-OCT-06 Client 8.6%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived

,Actinium-228 0.633

+/-0.160 Americium-241 U

0.0304

+/-0.0425 Bismuth-212 0.357

+/-0.290 Bismuth-214 0.411

+/-0.0995 Cesium-134 U

0.00458

+/-0.0269 Cesium-137 0.0841

+/-0.0353 Cobalt-60 U

0.0115

+/-0.0221 Europium-152 U

-0.0189

+/-0.0519 Europium-154 U

0.127

+/-0.110 Europium-155 U

0.0527

+/-0.0708 Lead-212 0.556

+/-0.0586 Lead-214 0.576

+/-0.0765 Manganese-54 U

0.0188

+/-0.0216 Niobium-94 U -0.00992

+/-0.0222 Potassium-40 10.2

+/-0.809 Radium-226 0.411

+/-0.0995 Silver-108m U

0.00271

+/-0.0178 Thallium-208 0.196

+/-0.0449 0.065 0.0269 0.151 0.0372 0.0233 0.0197 0.0198 0.0445 0.0645 0.0431 0.0362 0.0307 0.0197 0.0187 0.153 0.0372 0.0165 0.0198

+/-0.160

+/-0.0425

+/-0.290

+/-0.0995

+/-0.0269

+/-0.0353

+/-0.0221

+/-0.0519

+/-0.110

+/-0.0708

+/-0.0586

+/-0.0765

+/-0.0216

+/-0.0222

+/-0.809

+/-0.0995

+/-0.0178

+/-0.0449 0.139 0.0554 0.320 0.0782 0.0493 0.0417 0.043 0.0933 0.138 0.0889 0.0743 0.0645 0.0418 0.0395 0.341 0.0782 0.0347 0.0418 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 1837 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1128 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gei.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-01IFS Project:

YANK01204 Sample ID:

174224019 ClientlD:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low

,C Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UII Gamma Spectroscopy--Uncertain identification

  • X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-019F 174224020 TS 09-OCT-06 17-OCT-06 Client 9.97%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtc Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60

.Europium-152

-Europium-154

Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 0.709 U

-0.0317 0.464 0.472 U

0.0308 0.107 U

0.0134 U

0.0229 U

0.0133 U

0.0476 0.735 0.587 U

0.0188 U

0.0147 10.7 0.472 U

0.0181 0.250

+/-0.150

+/-0.119

+/-0.206

+/-0.0905

+/-0.0347

+/-0.0312

+/-0.0223

+/-0.0505

+/-0.0576

+/-0.055

+/-0.0682

+/-0.0883

+/-0.0228

+/-0.0182

+/-0.939

+/-0.0905

+/-0.0173

+/-0.0421 0.060 0.0823 0.119 0.0318 0.023 0.0169 0.0202 0.0444 0.0504 0.0531 0.0324 0.0335 0.0205 0.0167 0.176 0.0318 0.0165 0.0154

+/-0.150

+/-0.119

+/-0.206

+/-0.0905

+/-0.0347

+/-0.0312

+/-0.0223

+/-0.0505

+/-0.0576

+/-0.055

+/-0.0682

+/-0.0883

+/-0.0228

+/-0.0182

+/-0.939

+/-0.0905

+/-0.0173

+/-0.0421 0.130 0.171 0.257 0.068 0.049 0.0363 0.0445 0.0937 0.112 0.110 0.0671 0.0705 0.0437 0.0356 0.392 0.068 0.035 0.0332 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/23/06 2153 580184 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1128 580004 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 lnjun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-019F Proiect:

YANK01204 Sample ID:

174224020 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis

.D Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded

.J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more

.R Sample results are rejected

U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

.UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Certificateof A alvsis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Report Date:

October 24, 2006 Project:

Soils PO# 002332 Client Sample ID:

9520-0002-015F Proiect:

YANK01204 Sample ID:

174224021 Client ID:

YANK001 Matrix:

TS Vol. Recv.:

Collect Date:

09-OCT-06 Receive Date:

17-OCT-06 Collector:

Client Moisture:

11.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U

0.176 Curium-242 U

0.0202 Curium-243/244 U

0.126 Alphaspec Pu, Solid-ALL FSS Plutonium-238 U

0.00 Plutonium-239/240 U

-0.0186 Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U

-3.63

+/-0.185 0.0813

+/-0.187

+/-0.0803 0.0493 +/-0.0804

+/-0.203 0.129

+/-0.204

+1-0.0536 0.00 +/-0.0536

+/-0.0635 0.0649 +/-0.0635

+/-7.43 6.39

+/-7.43 Rad Gamma Spec Analysis

. Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.767 Americium-241 U

0.00809 Bismuth-212 0.594 Bismuth-214 0.499 Cesium-134 U

0.0488 Cesium-137 0.167 Cobalt-60 U

0.0189 Europium-152 U

0.0113 Europium-154 U

-0.0108 Europium-155 U

0.0838 Lead-212 0.608 Lead-214 0.587 Manganese-54 U -0.00162 Niobium-94 U

0.0142 Potassium-40 10.9 Radium-226 0.499 Silver-108m U-0.000455 Thallium-208 0.243 Rad Gas Flow Proportional Counting

+/-0.217

+/-0.0352

+/-0.317

+/-0.120

+/-0.0474

+/-0.0526

+/-0.0291

+/-0.0668

+/-0.0836

+/-0.096

+/-0.0803

+/-0.0952

+/-0.0278

+/-0.026

+/-1.01

+/-0.120

+/-0.0224

+/-0.053 0.0823 0.0313 0.152 0.0436 0.029 0.0245 0.026 0.0572 0.0694 0.0467 0.0413 0.0413 0.023 0.0229 0.207 0.0436 0.0199 0.0224

+/-0.217

+/-0.0352

+/-0.317

+/-0.120

+/-0.0474

+/-0.0526

+/-0.0291

+/-0.0668

+/-0.0836

+/-0.096

+/-0.0803

+/-0.0952

+/-0.0278

+/-0.026

+/-1.01

+/-0.120

+/-0.0224

+/-0.053 0.263 0.204 0.358 0.0741 0.204 13.4 0.176 0.0645 0.327 0.0919 0.0613 0.0517 0.0563 0.120 0.150 0.0968 0.085 0.0863 0.0491 0.0483 0.456 0.0919 0.0419 0.0473 0.0337 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g MXA 10/20/06 0813 580396 1

1 MXA 10/20/06 0813 580398 2

1 MXA 10/21/06 1649 580400 3

1 MJH 1 10/23/06 2156 580187 4

GFPC, Sr9O, solid-ALL FSS Strontium-90 0.0354

+/-0.0229 0.0142 +/-0.0229 KSD1 10/20/06 1939 580488 74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

9520-0002-015F 174224021 Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANKO01 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U

-2.18 Liquid Scint C14, Solid AllFSS Carbon-14 U

-0.105 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U

1.29 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U

-2.58 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U

0.285

+/-3.33 2.85

+/-3.33

+/-0.111 0.0955

+/-0.111

+/-30.8 22.5

+/-30.8

+/-9.45 8.04

+/-9.45

+/-0.255 0.210

+/-0.255 5.85 0.196 47.2 16.9 0.427 pCilg pCi/g pCi/g pCilg pCilg DFA1 10/23/06 1538 580401 6

AXD2 10/21/06 1537 580402 8

MXP1 10/23/06 0032 580395 9

MXP1 10/22/06 2019 580397 10 KXR1 10/24/06 0830 580399 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1131 580006 The following Analytical Methods were performed Method Description I

DOE EML HASL-300, Am-05-RC Modified 2

DOE EML HASL-300, Pu-11 -RC Modified 3

DOE EML HASL-300, Pu-I 1-RC Modified 4

EML HASL 300, 4.5.2.3 5

EPA 905.0 Modified 6

EPA 906.0 Modified 7

EPA 906.0 Modified 8

EPA EERF C-01 Modified 9

DOE RESL Fe-1, Modified 10 DOE RESL Ni-I, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery %

Acceptable Limits Americium-243 Plutonium-242 Plutonium-241 Strontium-90 Alphaspec Am241, Cm, Solid ALL Alphaspec Pu, Solid-ALL FSS Liquid Scint Pu241, Solid-ALL FS GFPC, Sr9O, solid-ALL FSS 82 95 91 98 (15%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

75

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 lnrun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 24, 2006 Client Sample ID:

Sample ID:

9520-0002-015F 174224021 Project:

YANK01204 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Iron-55 Nickel-63 Carrier/Tracer Recovery Technetium-99 Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS Liquid Scint Fe55, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Ni63, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS Liquid Scint Tc99, Solid-ALL FS 98 64 85 85 41 41 (25%-125%)

(15%-125%)

(25%-125%)

(25%-125%)

(15%-125%)

(15%-125%)

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

76

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-018F 174224022 TS 09-OCT-06 17-OCT-06 Client 9.08%

Proiect:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived

.Actinium-228 0.699

+/-0.111 Americium-241 U

0.0248

+/-0.0556 Bismuth-212 0.638

+/-0.174 Bismuth-214 0.425

+/-0.0601 Cesium-134 UI 0.00

+/-0.0336

  • Cesium-137 0.119

+/-0.0293

';Cobalt-60 U

0.0133

+/-0.0145

Europium-152 U

0.0025

+/-0.0361

'Europium-154 U

0.0155

+/-0.040

,Europium-155 U

0.0641

+/-0.0415 Lead-212 0.660

+/-0.044 Lead-214 0.525

+/-0.0554 Manganese-54 U

0.013

+/-0.0122 Niobium-94 U -0.00495

+/-0.0115 Potassium-40 10.6

+/-0.599 Radium-226 0.425

+/-0.0601 Silver-108m U-0.000768

+/-0.0124 Thallium-208 0.217

+/-0.0293 0.039 0.0489 0.082 0.0225 0.0138 0.0111 0.0131 0.0328 0.0349 0.0406 0.0185 0.0225 0.0115 0.00997 0.0937 0.0225 0.0096 0.0104

+/-0.111

+/-0.0556

+/-0.174

+/-0.0601

+/-0.0336

+/-0.0293

+/-0.0145

+/-0.0361

+/-0.040

+/-0.0415

+/-0.044

+/-0.0554

+/-0.0122

+/-0.0115

+/-0.599

+/-0.0601

+/-0.0124

+/-0.0293 0.083 0.101 0.174 0.0473 0.0291 0.0235 0.0281 0.0683 0.0748 0.0835 0.0383 0.0469 0.0244 0.0211 0.206 0.0473 0.0202 0.022 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g

.pCi/g pCi/g MJH1 10/23/06 2157 580187 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1131 580006 The following Analytical Methods were performed Method Description EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 77

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-018F Proiect:

YANK01204 Sample ID:

174224022 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded

.J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more

.R Sample results are rejected

'-U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification

-X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

78

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-021F 174224023 TS 11-OCT-06 17-OCT-06 Client 2.93%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.13

+/-0.239 Americium-241 U]

0.00

+/-0.0435 Bismuth-212 0.950

+/-0.349 Bismuth-214 0.878

+/-0.146 Cesium-134 U1 0.00

+/-0.0525 Cesium-137 0.0687

+/-0.0378 Cobalt-60 U

0.0468

+/-0.0414

.Europium-152 U

0.0503

+/-0.0926 Europium-154 U

-0.0343

+/-0.107

-Europium-155 U

0.037

+/-0.0631 Lead-212 1.02

+/-0.114 Lead-214 0.986

+/-0.146 Manganese-54 U

-0.0021

+/-0.0322 Niobium-94 U

0.0104

+/-0.0274 Potassium-40 14.8

+/-1.23 Radium-226 0.878

+/-0.146 Silver-108m U

-0.0337

+/-0.0263 Thallium-208 0.331

+/-0.0749 0.0919 0.0368 0.214 0.0484 0.0329 0.0291 0.031 0.0592 0.0864 0.057 0.0333 0.0425 0.0278 0.0247 0.219 0.0484 0.021 0.0254

+/-0.239

+/-0.0435

+/-0.349

+/-0.146

+/-0.0525

+/-0.0378

+/-0.0414

+/-0.0926

+/-0.107

+/-0.0631

+/-0.114

+/-0.146

+/-0.0322

+/-0.0274

+/-1.23

+/-0.146

+/-0.0263

+/-0.0749 0.184 0.0735 0.428 0.0968 0.0657 0.0582 0.062 0.118 0.173 0.114 0.0665 0,085 0.0555 0.0493 0.437 0.0968 0.0419 0.0508 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/23/06 2340 580187 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB 1 10/17/06 1131 580006 The following Analytical Methods were performed Method Description I

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 79

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. lack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-021F Project:

YANK01204 Sample ID:

174224023 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank

-BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more

.R Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

,UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

80

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 -. (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-022F 174224024 TS 11-OCT-06 17-OCT-06 Client 3.14%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch MtU Rad Gamma Spec Analysis Gamma, Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 1.23

+/-0.171 Americium-241 U

0.0453

+/-0.117 Bismuth-212 0.711

+/-0.245 Bismuth-214 0.833

+/-0.0947 Cesium-134 UI 0.00

+/-0.0299 Cesium-137 0.0902

+/-0.0242 Cobalt-60 0.0813

+/-0.0353

-Europium-152 U

-0.0581

+/-0.0517

.Europium-154 U

0.0196

+/-0.0608

'Europium-155 U

0.0461

+/-0.0522 Lead-212 1.02

+/-0.060 Lead-214 0.965

+/-0.0961 Manganese-54 U

0.00576

+/-0.0199 Niobium-94 U

0.00741

+/-0.0184 Potassium-40 15.7

+/-0.914 Radium-226 0.833

+/-0.0947 Silver-108m U-0.000439

+/-0.0162 Thallium-208 0.325

+/-0.0417 0.0614 0.0851 0.122 0.0292 0.0225 0.0168 0.0174 0.0414 0.0532 0.0503 0.0252 0.0306 0.0171 0.0162 0.137 0.0292 0.0145 0.0167

+/-0.171

+/-0.117

+/-0.245

+/-0.0947

+/-0.0299

+/-0.0242

+/-0.0353

+/-0.0517

+/-0.0608

+/-0.0522

+/-0.060

+/-0.0961

+/-0.0199

+/-0.0184

+/-0.914

+/-0.0947

+/-0.0162

+/-0.0417 0.131 0.175 0.258 0.0616 0.0472 0.0355 0.0377 0.0864 0.115 0.103 0.0521 0.0638 0.0362 0.034 0.304 0.0616 0.0303 0.0352 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCilg pCi/g MJH1 10/24/06 0614 580187 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1131 580006 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 81

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address :

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-022F Project:

YANK01204 Sample ID:

174224024 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte' has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte.was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

82

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date:

October 24, 2006 Client Sample ID:

Sample ID:

Matrix:

Collect Date:

Receive Date:

Collector:

Moisture:

9520-0002-023F 174224025 TS 12-OCT-06 17-OCT-06 Client 14.1%

Project:

Client ID:

Vol. Recv.:

YANK01204 YANK001 Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.715

+/-0.112 Americium-241 U

0,0307

+/-0.102 Bismuth-212 0.421

+/-0.170 Bismuth-214 0.581

+/-0.0767 Cesium-134 U

0.0251

+/-0.0205 Cesium-137 0.0419

+/-0.0255 Cobalt-60 U-0.000261

+/-0.0154 Europium-152 U

-0.0287

+/-0.0411 Europium-154 U

-0.0129

+/-0.0501 Europium-155 U

0.0243

+1-0.0505 Lead-212 0.746

+/-0.0499 Lead-214 0.670

+/-0.0636 Manganese-54 U

0.0143

+/-0.0174 Niobium-94 U

0.00291

+/-0.0148 Potassium-40 13.1

+/-0.725 Radium-226 0.581

+/-0.0767 Silver-108m U -0.00378

+/-0.0136 Thallium-208 0.234

+/-0.0322 0.0454 0.083 0.104 0.026 0.0167 0.0119 0.0132 0.0358 0.0425 0.0477 0.0211 0.027 0.0159 0.0133 0.117 0.026 0.0118 0.0126

+/-0.112

+/-0.102

+/-0.170

+/-0.0767

+/-0.0205

+/-0.0255

+/-0.0154

+1-0.0411

+/-0.0501

+/-0.0505

+/-0.0499

+/-0.0636

+/-0.0174

+/-0.0148

+/-0.725

+/-0.0767

+/-0.0136

+/-0.0322 0.0967 0.171 0.219 0.0545 0.0351 0.0253 0.0287 0.0746 0.091 0.0984 0.0437 0.0562 0.0333 0.0279 0.257 0.0545 0.0247 0.0265 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g MJH1 10/24/06 0614 580187 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 JMB1 10/17/06 1131 580006 The following Analytical Methods were performed Method Description 1

EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 83

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 24, 2006

Contact:

Mr. Jack McCarthy Project; Soils PO# 002332 Client Sample ID:

9520-0002-023F Project:

YANK01204 Sample ID:

174224025 Client ID:

YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U - Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

1U1 Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

84

QUALITY CONTROL DATA 85

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Report Date: October 24, 2006 Page 1 of 12 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

174224 Parmname NOM Sample Oual QC Units RPD%

REC%

Range Anist Date Time Rad Alpha Spec Batch 580396 QC1201210038 Americium-241 Curium-242 Curium-243/244 174224006 DUP U

-0.00901 Uncert:

+/-0.0461 TPU:

+/-0.0461 U

0.00 Uncert:

+/-0.0812 TPU:

+/-0.0812 U

0.00 Uncert:

+/-0.0764 TPU:

+/-0.0764 QC 1201210040 LCS Americium-241 Curium-242 Curium-243/244 QC1201210037 MB Americium-241 Curium-242 Curium-243/244 QC1201210039 174224006 MS Americium-241 Curium-242 Curium-243/244 2.72 Uncert:

TPU:

Uncert:

TPU:

3.27 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.0356

+/-0.035

+/-0.0352 U

-0.0155

+/-0.0215

+/-0.0216 U

-0.0556

+/-0.123

+/-0.123 2.33

+/-0.266

+/-0.392 U

0.00823

+/-0.0232

+/-0.0232 3.55

+/-0.330

+/-0.549 U

2.200E-05

+/-0.0261

+/-0.0261 U

0.00

+/-0.0134

+/-0.0134 U

-0.00919

+/-0.0222

+/-0.0222 pCi/g 119 pCi/g 200 pCi/g 200 (0% - 100%) AXAI (0% - 100%)

(0%-100%)

10/20/06 08:13 PCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g 86 (75%-125%)

10/20/06 08:13 109 (75%-125%)

10/20/06 08:13 13.3 U

-0.00901 Uncert:

+/-0.0461 TPU:

+/-0.0461 U

0.00 Uncert:

+/-0.0812 TPU:

+/-0.0812 16.1 U

0.00 Uncert:

+/-0.0764 TPU:

+/-0.0764 U

13.9

+/-1.44

+/-2.27 0.0808

+/-0.112

+/-0.112 18.4

+/-1.66

+/-2.87 105 (75%-125%)

10/20/06 08:13 114 (75%-125%)

Batch 580398 QC1201210046 174224006 DUP Plutonium-238 U

0.00905 U

0.0116 pCi/g 25 (0% - 100%) AXAI 10/20/06 08:13 86

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 2 of 12 Parmname NOM Sample Qua]

QC Units RPD%

REC%

Range Anist Date Time Rad Alpha Spec Batch 580398 Plutonium-239/240 Uncert:

+/-0.086 TPU:

+/-0.086 u

-0.0532 Uncert:

+/-0.0721 TPU:

+/-0.0723 U

+/-0.121

+/-0.121 0.0814

+/-0.112

+/-0.112 pCi/g 955 (0%-100%)

(75%-125%)

QC1201210048 LCS Plutonium-238 Plutonium-239/240 QC1201210045 MB Plutonium-238 Plutonium-239/240 QC1201210047 174224006 MS Plutonium-238 Uncelt TPU:

2.51 Uncert:

TPU:

Uncert TPU:

Uncert:

TPU:

U

-0.00419

+/-0.0143

+/-0.0143 2.38

+/-0.238

+/-0.332 U

-0.0118

+/-0.018

+/-0.018 U

-0.00516

+/-0.00584

+/-0.00586 pCi/g pCilg P019g pCi/g pCig pCilg 10/20/06 08:13 95 (75%-125%)

10/20/06 08:13 Plutonium-239/240 u

0.00905 Uncert

+/-0.086 TPU:

+/-0.086 12.3.

U

-0.0532 Uncert:

+/-0.0721 TPU:

+/-0.0723 u

-4.06 Uncert:

+/-7.84 TPU:

+/-7.84 U

-0.0482

+/-0.0653

+/-0.0654 15.4

+/-1.23

+/-1.94 (75%-125%)

125 (75%-125%)

Batch 580400 QC1201210054 174224006 DUP Plutonium-241 QC1201210056 LCS Plutonium-241 u

-1.47

+/-6.92

+/-6.92 35.5

+/-3.19

+/-4.69 pC01 0

(0% - 100%) vIXA1 QC1201210053 MB Plutonium-241 35.9 Uncert TPU:

Uncei=

TPU:

143 U

Uncert TPU:

QC1201210055 Plutonium-241 174224006 MS U

-0.233

+/-1.77

+/-1.77 124

+/-11.4

+/-16.4 1301g PCilg pcilg 99 (75%-125%)

10/21/06 18:42 10/21/06 19:14 10/21/06 18:26 10/21/06 18:58

-4.06

+/-7.84

+/-7.84 86 (75%-125%)

Rad Gamma Spec Batch 580184 QC1201209530 174224001 DUP Actinium-228 0.656

+/-0.149 Uncert 0.713

+/-0.114

+/-0.114 pCilg 8

(0% - 100%) MJH1 10/23/06 21:59 87

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charlesimn SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 3 of 12 Parmname NOM Sample Qm QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 580184 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 TPU:

+/-0.149 U

-0.0484 U

-0.009 Uncert:

+/-0.120

+/-0.0993 TPU:

+/-0.120

+/-0.0993 0.740 0.587 Uncert:

+/-0.207

+/-0.190 TPU:

+/-0.207

+/-0.190 0.521 0.572 Uncert:

+/-0.0704

+/-0.0709 TPU:

+/-0.0704

+/-0.0709 U

0.0423 U

0,0299 Uncert:

+/-0.0387

+/-0.0245 TPU:

+/-0.0387

+/-0.0245 0.053 U

0.0266 Uncert:

+/-0.0324

+/-0.0247 TPU:

+/-0.0324

+/-0.0247 u

0.00102 U

0.000496 Uncert:

+/-0.0188

+/-0.0137 TPU:

+/-0.0188

+/-0.0137 U

-0.00774 U

0.0158 Uncert:

+/-0.0461

+/-0.0371 TPU:

+/-0.0461

+/-0.0371 U

-0.0447 U

-0.0102 Uncert:

+/-0.0569

+/-0.0472 TPU:

+/-0.0569

+/-0.0472 U

0.035 U

0.0663 Uncert:

+/-0.0562

+/-0.0598 TPU:

+1-0.0562

+J-0.0598 0-730 0.681 Uncert:

+/-0.0581

+/-0.0478 TPU:

+/-0.0581

+/-0.0478 0.572 0.586 Uncert:

+/-0.0735

+/-0.0627 TPU:

+/-0.0735

+/-0.0627 U

0.002 U

0.019 Uncert:

+/-0.0188

+/-0.0175 TPU:

+/-0.0188

+/-0.0175 U

0.00326 U

0.0155 Uncert:

+/-0.0161

+/-0.0162 TPU:

+/-0.0161

+/-0.0162 10.7 10.9 Uncert:

+/-0.759

+/-0.617 TPU:

+/-0.758

+/-0.617 0.521 0.572 Uncert:

+/-0.0704

+/-0.0709 TPU:

+/-0.0704

+/-0.0709 U

-0.00426 U

-0.00499 Uncert:

+1-0.0157

+/-0.0125 pCi/g 137 pCi/g 23 pCi/g 9

pCi/g 34 pCi/g 66 pCi/g 69 pCi/g 583 pCi/g 126 pCilg 62 pCilg 7

pCi/g 2

pCi/g 162 pCi/g 131 pCi/g 2

pCi/g 9

pCi/g 16 (0%- 100%)

(0%- 100%)

(0%- 100%)

(0% - 100%)

(0% - 100%)

(0% - 100%)

(0%- 100%)

(0% -100%)

(0% - 100%)

(0% - 20%)

(0%-20%)

(0% - 100%)

(0%- 100%)

(0% - 20%)

(0%- 100%)

(0% - 100%)

Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m 88

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Workorder:

174224 Parmname Rad Gamma Spec Batch 58M84 Thallium-208 QC 1201209531 LCS Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-i 54 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 QC Summary Samnle Oual OC NOM Units RPD%

Page 4 of 12 REC%

Range AnIst Date Time Units R.PD%

TPU:

Uncert:

TPU:

Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.55 Uncert:

TPU:

14.2 Uncen:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncen:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.0157 0.249

+/-0.0433

+/-0.0433

+/-0.0125 0.228

+/-0.0352

+/-0.0352 U

0.0686

+/-0.595

+/-0.595 25.1

+/-1AI

+/-1.41 U

-0.18

+/-0.939

+/-0.939 U

-0.0765

+/-0.206

+/-0.206 U

0.141

+/-0.115

+/-0.115 10.1

+/-0.480

+/-0.480 14.8

+/-0.669

+/-0.669 U

0.426

+/-0.272

+/-0.272 U

-0.119

+/-0.260

+/-0.260 U

-0.057

+/-0.272

+/-0.272 U

0.0794

+/-0.141

+/-0.141 U

0.122

+/-0.202

+/-0.202 U

-0.0237

+/-0.129

+/-0.129 U

-0.0208

+/-0.108

+/-0.108 U

0.464 pCi/g 9

(0% - 100%)

pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCilg pCilg pCi/g pCi/g pCilg pCi/g pCilg 10/23/06 18:35 107 (75%-125%)

106 (75%-125%)

104 (75%-125%)

89

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 5 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 580184 Radium-226 Silver-I 08m Thallium-208 QC1201209529 Actinium-228 Americiurn-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 MB Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

.TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-1.08

+1-1.08 U

-0.0765

+/-0.206

+/-0.206 U

0.0616

+/-0.104

+/-0.104 U

0.180

+/-0.223

+/-0.223 U

0.00591

+/-0.0418

+/-0.0418 U

-0.00933

+/-0.0122

+/-0.0122 U

-0.0657

+/-0.0939

+/-0.0939 U

0.0217

+/-0.0605

+/-0.0605 U

0.0108

+/-0.00984

+/-0.00984 U

-0.0074

+/-0.0107

+/-0.0107 U

-0.00733

+/-0.0157

+/-0.0157 U

0.0152

+/-0.0297

+/-0.0297 U

0.00447

+/-0.0325

+/-0.0325 U

-0.0125

+/-0.0232

+/-0.0232 UI 0.00

+/-0.0285

+/-0.0285 U

0.0313

+/-0.0541

+/-0.0541 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g pCi/g pCilg pCi/g pCilg PCi/g (75%-125%)

10/23/06 21:55 90

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 6 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 580184 Manganese-54 Niobium-94 Potassium-40 Radium-226 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

U

-0.00428

+/-0.0125

+/-0.0125 U

0.00916

+/-0.0116

+/-0.0116 U

0.0648

+/-0.114

+/-0.114 U

0.0217

+/-0.0605

+/-0.0605 U

0.00203

+/-0.00957

+/-0.00957 U

-0.00106

+/-0.0125

+/-0.0125 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g Silver-108m Thallium-208

. Batch 580187 QC1201209537 174224021 DUP Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 0.767 0.652 Uncert:

+/-0.217

+/-0.144 TPU:

+/-0.217

+/-0.144 U

0.00809 U

-0.00863 Uncert:

+/-0.0352

+/-0.0585 TPU:

+/-0.0352

+/-0.0585 0.594 0.486 Uncert:

+/-0.317

+/-0.244 TPU:

+/-0.317

+/-0.244 0.499 0.519 Uncert:

+/-0.120

+/-0.0642 TPU:

+/-0.120

+/-0.0642 U

0.0488 U

0.0182 Uncert:

+/-0.0474

+/-0.0194 TPU:

+/-0.0474

+/-0.0194 0.167 0.162 Uncert:

+/-0.0526

+/-0.0267 TPU:

+/-0.0526

+/-0.0267 U

0.0189 U

0.000551 Uncert:

+/-0.0291

+/-0.0152 TPU:

+/-0.0291

+/-0.0152 U

0.0113 U

0.015 Uncert:

+/-0.0668

+/-0.0384 TPU:

+/-0.0668

+/-0.0384 U

-0.0108 U

0.0378 Uncert:

+/-0.0836

+/-0.0469 TPU:

+/-0.0836

+/-0.0469 U

0.0838 U

-0.000498 pCi/g 16 pCi/g 6190 pCi/g 20 pCi/g 4

pCi/g 91 pCi/g 3

pgi/g 189 pCi/g 28 pCi/g 359 pCi/g 202 (0%- 100%) MJH1 10/24/06 08:02 (0%- 100%)

(0%- 100%)

(0%- 100%)

(0% - 100%)

(0% - 100%)

(0% -100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

91

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn QC Summary Workorder:

174224 Page 7 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 580187 Lead-212 Lead-214 Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QC1201209538 Actinium-228 Americium-241 Bismuth-212 Uncert:

+/-0.096 TPU:

+/-0.096 0.608 Uncert:

+/-0.0803 TPU:

+/-0.0803 0.587 Uncert:

+/-0.0952 TPU:

+/-0.0952 U

-0.00162 Uncert:

+/-0.0278 TPU:

+/-0.0278 U

0.0142 Uncert:

+/-0.026 TPU:

+/-0.026 10.9 Uncert:

+/-1.01 TPU:

+/-1.01 0.499 Uncert:

+/-0.120 TPU:

+/-0.120 U

-0.000455 Uncert:

+/-0.0224 TPU:

+/-0.0224 0.243 Uncert:

+/-0.053 TPU:

+/-0.053

+/-0.0484

+/-0.0484 0.735

+/-0.0516

+/-0.0516 0.561

+/-0.0695

+/-0.0695 U

0.00615

+/-0.0152

+/-0.0152 U

-0.00557

+/-0.0139

+/-0.0139 11.0

+/-0.689

+/-0.689 0.519

+/-0.0642

+/-0.0642 U

-0.00219

+/-0.0131

+/-0.0131 0.197

+/-0.0337

+/-0.0337 U

-0.0897

+/-0.577

+/-0.577 24.3

+/-1.14

+/-1.14 U

-0.369

+/-0.925

+/-0.925 U

0.128

+/-0.218

+1-0.218 U

-0.0937

+/-0.140

+/-0.140 9.91

+/-0.493

+/-0.493 14.8

+/-0.650

+/-0.650 pCi/g 19 pCi/g 4

pCi/g 343 pCi/g 457 pCilg I

pCi/g 4

pCi/g 131 pCi/g 21 (0% - 20%)

(0% - 20%)

(0%- 100%)

(0%- 100%)

(0%-20%)

(0% - 100%)

(0%- 100%)

(0% ý 100%)

LCS Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.55 Uncert:

TPU:

14.2 Uncert:

TPU:

pCi/g PCi/g PCi/g PCi/g pCi/g pCi/g pci/g 104 (75%-125%)

10/24/06 10:50 104 (75%-125%)

104 (75%-125%)

92

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 8 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 580187 Europium-152 U

-0.0694 pCi/g Uncert:

+/-0.284 TPU:

+/-0.284 Europium-154 U

-0.104 pCi/g Uncert:

+/-0.261 TPU:

+/-0.261 Europium-155 U

-0.0225 pCi/g Uncert:

+/-0.279 TPU:

+/-0.279 Lead-212 U

0.101 pCi/g Uncert:

+/-0.140 TPU:

+/-0.140 Lead-214 U

0.197 pCi/g Uncert:

+/-0.213 TPU:

+/-0.213 Manganese-54 U

0.0802 pCi/g Uncert:

+/-0.131 TPU:

+/-0.131 Niobium-94 U

-0.0585 pCi/g Uncert:

+/-0.108 TPU:

+/-0.108 Potassium-40 U

-0.227 pCi/g Uncert:

+/-0.915 TPU:

+/-0.915 Radium-226 U

0.128 pCi/g (75%-125%)

Uncert:

+/-0.218 TPU:

+/-0.218 Silver-108m U

-0.0271 pCi/g Uncert:

+/-0.105 TPU:

+/-0.105 Thallium-208 U

0.134 pCi/g Uncert:

+/-0.116 TPU:

+/-0.116 QC1201209536 MB Actinium-228 U

-0.0025 pCi/g 10/24/06 06:30 Uncert:

+/-0.0518 TPU:

+/-0.0518 Americium-241 U

-0.000862 pCi/g Uncert:

+/-0.0133 TPU:

+/-0.0133 Bismuth-212 U

-0.0126 pCi/g Uncert:

+/-0.120 TPU:

+/-0.120 Bismuth-214 U

0.0408 pCi/g Uncert:

+/-0.0373 TPU:

+/-0.0373 Cesium-134 U

0.00104 pCi/g Uncert:

+/-0.027 93

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 9 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 580187 TPU:

+/-0.027 Cesium-137 U

0.00755 pCi/g Uncert:

+/-0.0324 TPU:

+/-0.0324 Cobalt-60 U

0.00568 pCi/g Uncert:

+/-0.0178 TPU:

+/-0.0178 Europium-152 U

-0.00618 pCi/g Uncert:

+/-0.0385 TPU:

+/-0.0385 Europium-154 U

-0.0333 pCi/g Uncert:

+/-0.0578 TPU:

+/-0.0578 Europium-155 U

0.020 pCi/g Uncert:

+/-0.0245 TPU:

+/-0.0245 Lead-212 U

0.0108 pCi/g Uncert:

+/-0.0301 TPU:

+/-0.0301 Lead-214 U

0.0223 pCi/g Uncert:

+/-0.0434 TPU:

+/-0.0434 Manganese-54 U

0.00703 pCi/g Uncert:

+/-0.0177 TPU:

+/-0.0177 Niobium-94 U

0.00524 pCi/g Uncert:

+/-0.016 TPU:

+/-0.016 Potassium-40 U

0.0126 pCi/g Uncert:

+/-0.174 TPU:

+/-0.174 Radium-226 U

0.0408 pCi/g Uncert:

+/-0.0373 TPU:

+/-0.0373 Silver-108m U

0.00672 pCi/g Uncert:

+/-0.0132 TPU:

+/-0.0132 Thallium-208 U

0.00821 pCi/g Uncert:

+/-0.0182 TPU:

+/-0.0182 Rad Gas Flow Batch 580488 QC1201210299 174224006 DUP Strontium-90 U

0.0274 U

0.019 pCi/g 0

(0% - 100%) KSD1 10/23/06 14:39 Uncert:

+/-0.0243

+/-0.0165 TPU:

+/-0.0243

+/-0.0165 QC1201210301 LCS Strontium-90 1.48 1.21 pCi/g 82 (75%-125%)

10/21/06 08:50 94

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 10 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gas Flow Batch 580488 QC1201210298 MB Strontium-90 QC1201210300 174224006 MS Strontium-90 Rad Liquid ScntMation Batch 580395 Uncert:

TPU:

Uncert:

TPU:

+/-0.0826

+/-0.0897 U

-0.000851

+/-0.0154

+/-0.0154 pCi/g pci/g 10/21/06 08:50 10/21/06 08:50 3.12 U

Uncert:

TPU:

0.0274

+/-0.0243

+/-0.0243 2.73

+/-0.188

+/-0.204 88 (75%-125%)

QC1201210034 Iron-55 174224006 DUP U

2.10 Uncert:

+/-28.7 TPU:

+/-28.7 U

6.20

+/-29.1

+/-29.1 pCi/g 0

(0% - 100%) VIXPI QC1201210036 LCS Iron-55 QC1201210033 MB Iron-55 QC1201210035 174224006 MS Iron-55 607 Uncert:

TPU:

Uncert:

TPU:

666 U

Uncert:

TPU:

623

+/-52.8

+/-73.5 U

2.58

+/-32.0

+/-32.0 pCi/g pCi/g pCi/g 103 (75%-125%)

10/23/06 02:29 10/23/06 03:02 10/23/06 02:12 10/23/06 02:45 2.10

+/-28.7

+/-28.7 Batch 580397 631

+/-52.7

+/-73.8

-5.26

+/-8.14

+/-8.14 95 (75%-125%)

QC1201210042 174224021 DUP Nickel-63 QC1201210044 LCS Nickel-63 QC1201210041 MB Nickel-63 QC1201210043 174224021 MS Nickel-63 U

-2.58 Uncert:

+/-9.45 TPU:

+/-9.45 180 Uncert:

TPU:

Uncert:

TPU:

U pCi/g 0

(0% - 100%) VLXP1 158

+/-7.84

+/-8.98 U

0.00

+/-2.82

+/-2.82 446

+/-21.3

+/-26.8 pCi/g pCi/g pCi/g 88 (75%-125%)

77 (75%-125%)

10/22/06 22:13 10/22/06 22:46 10/22/06 21:57 10/22/06 22:30 577 U

Uncert:

TPU:

-2.58

+/-9.45

+/-9.45 Batch 580399 QC1201210050 174224006 DUP Technetium-99 U

0.148 U

0.00881 pCi/g 0

(0% - 100%) KXR1 10/24/06 14:39 95

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 11 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Liquid Scintillation Bamtr 580399 Uncert:

+/-0.198 TPU:

+/-0.198 QC1201210052 LCS Tedmetium-99 QC1201210049 MB Technetium-99

+/-0.205

+/-0.205 12.5

+/-0.470

+/-0.548 13.0 Uncert:

TPU:

Uncert:

TPU:

13.1 U

Uncert:

TPU:

U 0.0518

+/-0.182

+/-0.182 pCi/g pCi/g pCi/g 96 (75%-125%)

10/24/06 15:12 10/24/06 14:23 10/24/06 14:55 QC 1201210051 Technetium-99 1742240M MS 0.148

+/-0.198

+/-0.198 B2=h 580401 QC1201210058 17422406 DUP Tfitium QC1201210060 LCS Tkijium U

-0.10 Uncert:

+/-2.79 TPU:

+/-2.79 u

12.3

+/-0.495

+/-0.569 0.102

+/-2.85

+/-2.85 10.7

+/-2.15

+/-2.16 94 (75%-125%)

pCi/g 0

(0% - 100%) DFA I QC1201210057 MB Trtium 10.7 Uncert:

TPU:

Uncert:

TPU:

48.4 U

Uncert:

TPU:

U 1.20

+/-1.56

+/-1.56 pCi/g pCi/g pCi/g 100 (75%-125%)

10/23/06 17:41 10/20/06 00:59 10/20/06 00:10 10/20/06 00:43 QC1201210059 174224006 MS Tkitium Bz1rh 580402 QC1201210062 17422411(M DUP Carbon-14 QC1201210064 LCS C.abon-14

-0.10

+/-2.79

+/-2.79 u

-0.105 Uncert:

+/-0.111 TPU:

+/-0.111 u

51.7

+/-10.2

+/-10.3

-0.0719

+/-0.109

+/-0.109 7.04

+/-0.236

+/-0.261 107 (75%-125%)

pCi/g 0

(0%- 100%) 4XD2 10/21/06 19:32 QC1201210061 MB Carbon-14 6.99 Uncert:

TPU:

Uncert:

TPU:

7.06 U

Uncert:

TPU:

U

-0.0996

+/-0.108

+/-0.108 pCi/g pCi/g pCi/g 101 (75%-125%)

10/21/06 21:06 10/21/06 18:45 10/21/06 20:19 QC1201210063 174224(M MS Cmblon-14

-0.105

+/-0.111

+/-0.111 6.82

+/-0.237

+/-0.260 97 (75%-125%)

96

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174224 Page 12 of 12 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time 8

Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product 3

Target analyte was detected in the associated blank 3D Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GCIMS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded I

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

97

General Narrative 1

General Narrative for Connecticut Yankee Atomic Power Co.

Work Order: 174341 SDG: MSR#06-1376 October 24,2006 Laboratory Identification:

General Engineering Laboratories, LLC 2040 Savage Road Charleston, South Carolina 29407 (843) 556-8171 Summary Sample receipt The sample arrived at General Engineering Laboratories, LLC, Charleston, South Carolina on October 18, 2006 for analysis. Shipping container temperature was checked, documented, and within specifications. The sample was delivered with proper chain of custody documentation and signatures. All sample containers arrived without any visible signs of tampering or breakage.

Sample Identification The laboratory received the following sample:

Laboratory Sample Identification Description 174341001 9520-0002-024F Items of Note There are no items to note.

Case Narrative Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL)

Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are contained in the analytical case narratives in the enclosed data package.

Analytical Request One soil sample was analyzed for FSSGAM.

Data Package The enclosed data package contains the following sections: General Narrative, Chain of Custody and Supporting Documentation, Data Review Qualifier Definitions, and data from the following fractions: Radiochemistry.

I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.

Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171 - FaxZ43) 766-1178 www.gel.com

List of current GEL C*erlfications as of 24 October 2006 State Certification Alaska UST-062 Arizona AZ0668 Arkansas 88-0651 CLIA 42D0904046 California 01151CA Colorado GenEngLabs Connecticut PH-0169 Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia E87156 (FLJNELAP)

Hawaii N/A Idaho N/A Illinois 200029 Indiana C-SC-01 Kansas E-10332 Kentucky 90129 Louisiana 03046 Maryland 270 Massachusetts M-SCO12 Michigan 9903 Nevada SC12 New Jersey SC002 New Mexico FL NELAP E87156 New York 11501 North Carolina 233 North Carolina Drinking W 45709 North Dakota R-158 Oklahoma 9904 Pennsylvania 68-00485 South Carolina 10120001/10585001/10120002 Tennessee 02934 Texas TX213-2006A Texas NELAP T104704235-06-TX U.S. Dept. of Agriculture S-52597 US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont VT87156 Virginia 00151 Washington C1641 3

Chain of Custody and Supporting Documentation 4

t4ilhih phy~igh 13ogduiu UPP-60CIR-R5 I 4-OO1 -Attach me Ht BA-tCV-0 1 Mtij t Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00635 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested LabUse Ol*y.,

Contact Name & Phone:

Comments:

Jack McCarthy 860-267-3924 Analytical Lab (Name, City, State)

General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0

843 556 8171. Attn. Cheryl Jones Priority: '] 30 D. Ei 14 D. CE 7 D. -- 3 D.Container Sample Size-Sample Designation Date Time Media Type

&Type Comment, Preservation Lab:Samrple ID Code Code Code 9520-0002-024F 10/16/06 1327 TS G

BP X

NOTES: PO #: 002332 MSR #: 06-1371. SSWP# NA E LTP QA LI Radwaste QA Li Non QA Samples Shipped Via:

E Fed Ex L-ups L] Hand El Other

-7i o?.2og #'o4t Bill of Lading #t Internal Container Temp.:,.. 'Deg.

C Custody Sealed?

Y 15-` N.

Custody Seal Intact?

Y 9 N l

1) Relnu d B~

Date/Time

2) Received By Date/Time lt

.oz -

I "I

4 1

3) &rinquisffed By Date/Time
4) Received By Date/Time

Connecticut Yankee Statement of Work for Analytical Lab Services

  • CY-ISC-SOW-O01 Fig Date/Time Received:

Io- /

a-ure 1. Sample Check-in List

.3.

,A&

Work Order Number_

t1 H~.~~+~,

I-L Shipping Cdntainer ID: 2f*,.?c$,

9/ (* 9 Chain of Custody #00o06 00

/ oIC '.iL WO*,3)

1.

Custody Seals oi shipping container intact?.

Yes

[N]o

2.

Custody Seals dated and signed?

Yes[ [No [C] "tt4

3.

Chain-of-Custody record present?

Yes [

o.
4.

Cooler temperature 11

5.

Vermiculite/packing materials is:

Wet [ ] Dry [* ]

A/A 6.'

Number of samples in shipping container: _

__r_.,__.

7.

Sample holding times exceeded?

Yes [

No [b""

.8. Samples have:

tape hazard labels custody seals appropriate sample labels

9. Samples are:

od condition

-leaking

-broken

____have air bubbles

10.

Were any anomalies identified in sample receipt?

Yes [] No 11...

Description of anomalies (include sample numbers):

Sample Custodian/Laboratory:

Telephoned to:__

On By Date: -- /

f--

7

Data Review Qualifier Definitions 7

Data Review Qualifier Definitions Qualifier Explanation A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound Result is less than value reported Result is greater than value reported RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank B

Metals-Either presence of analyte detected in the associated blank, or MDL/IDL < sample value < PQL BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample d

5-day BOD-The 2:1 depletion requirement was not met for this sample E

Organics-Concentration of the target analyte exceeds the instrument calibration range E

Metals-%difference of sample and SD is

>10%.

Sample concentration must meet flagging criteria H

Analytical holding time was exceeded h

Preparation or preservation holding time was exceeded J

Value is estimated N

Metals-The Matrix spike sample recovery is not within specified control limits' N

Organics-Presumptive evidence based on mass spectral library search to make a tentative identification of the analyte (TIC).

Quantitation is based on nearest internal standard response factor N/A Spike recovery limits do not apply.

Sample concentration exceeds spike concentration by 4X or more ND Analyte concentration is not detected above the reporting limit UI Gamma Spectroscopy-Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound Z

Paint Filter Test-Particulates passed through the filter, however no free liquids were observed.

GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.

P.O. BOX 30712 Charleston, SC 29417 - 2040 Savage Road (29407)

Phone (843) 556-8171

  • Fax&43) 766-1178 www.gel.com

RADIOLOGICAL ANALYSIS 9

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

Work Order 174341 Method/Analysis Information Product:

Analytical Method:

Prep Method:

Analytical Batch Number:

Prep Batch Number:

Sample ID 174341001 1201213157 1201213158 1201213159 Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived EML HASL 300, 4.5.2.3 Dry Soil Prep 581675 580480 Client ID 9520-0002-024F Method Blank (MB) 174346001(9520-0004-00iF) Sample Duplicate (DUP)

Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 13.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 174346001 (9520-0004-001F).

10

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Sample 174341001 (9520-0002-024F) was recounted due to high MDA.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.

Additional Comments Additional comments were not required for this sample set.

Qualifier information Qualifier Reason Analyte Sample U'

Data rejected due to high counting uncertainty.

Potassium-40 1201213157 Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Lýc eý 10/,

Reviewer/Date:

I 11

SAMPLE DATA

SUMMARY

12

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#06-1376 GEL Work Order: 174341 The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Analyte is a surrogate compound U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the detection limit.

The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 13

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company:

Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Report Date: October 26, 2006 Client Sample ID:

9520-0002-024F Project:

YANK01204 Sample ID:

174341001 Client ID:

YANKOOI Matrix:

Soil Vol. Recv.:

Collect Date:

16-OCT-06 Receive Date:

18-OCT-06 Collector:

Client Moisture:

5.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Actinium-228 0.995

+/-0.191 Americium-241 U

0.0843

+/-0.113 Bismuth-212 0.775

+/-0.282 Bismuth-214 0.881

+/-0.0992 Cesium-134 U

0.043

+/-0.0318 Cesium-137 0.0469

+/-0.0259 Cobalt-60 U

0.011

+/-0.0225 Europium-152 U -0.00948

+/-0.0515 "Europium-154 U

0.006

+/-0.0634 Europium-155 U

0.0556

+/-0.0732 Lead-212 1.06

+/-0.0676 Lead-214 1.02

+/-0.0948 Manganese-54 U

0.0177

+/-0.020 Niobium-94 U -0.00361

+/-0.0192 Potassium-40 13.6

+/-0.909 Radium-226 0.881

+/-0.0992 Silver-108m U

0.0137

+/-0.0161 Thallium-208 0.337

+/-0.0436 0.0671 0.097 0.138 0.0322 0.0249 0.0177 0.0202 0.0439 0.0547 0.0501 0.026 0.0309 0.017 0.0163 0.149 0.0322 0.0154 0.0145

+/-0.191

+/-0.113

+/-0.282

+/-0.0992

+/-0.0318

+/-0.0259

+/-0.0225

+/-0.0515

+/-0.0634

+/-0.0732

+/-0.0676

+/-0.0948

+/-0.020

+/-0.0192

+/-0.909

+/-0.0992

+/-0.0161

+/-0.0436 0.144 0.200 0.294 0.0683 0.0524 0.0377 0.0441 0.0923 0.119 0.104 0.054 0.065 0.0365 0.0347 0.335 0.0683 0.0325 0.0312 pCiig pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCilg pCi/g pCi/g pCi/g pCi/g pCi/g MJHI 10/25/06 1522 581675 1

The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 10/18/06 1634 580480 The following Analytical Methods were performed Method Description I

EML HASL 300,4.5.2.3 Notes:

The Qualifiers in this report are defimed as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported 14

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address:

362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: October 26, 2006

Contact:

Mr. Jack McCarthy Project:

Soils PO# 002332 Client Sample ID:

9520-0002-024F Proiect:

YANK01204 Sample ID:

174341001 Client ID:

YANK001 Vol. Recv.:

Parameter Quallifier Result Uncertainty LC TPU AMIA units DF Analyst Date Time Batch Mt(

Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected

'U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.

15

i QUALITY CONTROL DATA 16

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Client :

Connecticut Yankee Atomic Power 362 Injun Hollow Rd Reoort Date: October 26, 2006 Page I of 5 East Hampton, Connecticut

Contact:

Mr. Jack McCarthy Workorder:

174341 Parmname NAM Samnie Aual OC Units RPD %

REC%

Rante Anlst Date Time Parmname NO Samnle Oual OC Units RPD%

Rad Gamma Spec Batch 581675 QC1201213158 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesiurn-137 Cobalt-60 Europium-152 Europium-154 Europium-155 Lead-212 Lead-214 Manganese-54 Niobium-94 174346001 DUP 0.739 Uncert:

+/-0.156 TPU:

+/-0.156 U

-0.00139 Uncert:

+/-0.0236 TPU:

+/-0.0236 0.368 Uncert:

+/-0.265 TPU:

+/-0.265 0.442 Uncert:

+/-0.0807 TPU:

+/-0.0807 UI 0.00 Uncert:

+/-0.0441 TPU:

+/-0.0441 U

0.0319 Uncert:

+/-0.0333 TPU:

+/-0.0333 U

-0.00636 Uncert:

+/-0.0198 TPU:

+/-0.0198 U

0.00386 Uncert:

+/-0.0449 TPU:

+/-0.0449 U

0.0267 Uncert:

+/-0.0569 TPU:

+/-0.0569 U

0.0194 Uncert:

+/-0.0412 TPU:

+/-0.0412 0.412 Uncert:

+/-0.0541 TPU:

+/-0.0541 0.499 Uncert:

+/-0.0827 TPU:

+/-0.0827 U

0.00185 Uncert:

+/-0.0195 TPU:

+/-0.0195 U

-0.00452 Uncert:

+/-0.0184 TPU:

+/-0.0184 0.528

+/-0.123

+/-0.123 U

0.0268

+/-0.0262

+/-0.0262 0.431

+/-0.250

+/-0.250 0.468

+/-0.0892

+/-0.0892 U

0.0283

+/-0.0245

+/-0.0245 0.0366

+/-0.0293

+/-0.0293 U

0.020

+/-0.0248

+/-0.0248 U

0.00827

+/-0.0545

+/-0.0545 U

0.0258

+/-0.0664

+/-0.0664 U

0.0266

+/-0.0399

+/-0.0399 0.485

+/-0.0603

-+/-0.0603 0.530

+/-0.0836

+/-0.0836 U

0.0212

+/-0.0239

+/-0.0239 U

0.0106

+/-0.0182

+/-0.0182 pCi/g 33 pCi/g 222 pCi/g 16 pCi/g 6

pCi/g 75 pCi/g 14 pCi/g 387 pCi/g 73 pCi/g 3

pCi/g 31 pCi/g 16 pCi/g 6

pCi/g 168 pCi/g 496 (0%- 100%) MJH1 10/25/06 11:04 (0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%- 100%)

(0%-20%)

(0%- 100%)

(0%- 100%)

17

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174341 Page 2 of 5 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 581675 Potassium-40 Radium-226 Silver-108m Thallium-208 6.70 Uncert:

+/-0.609 TPU:

+/-0.609 0.442 Uncert:

+/-0.0807 TPU:

+/-0.0807 U

0.00712 Uncert:

+/-0.0152 TPU:

+/-0.0152 0.183 Uncert:

+/-0.0403 TPU:

+/-0.0403 QC1201213159 Actinium-228 Americium-241 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 LCS Uncert:

TPU:

23.4 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

9.55 Uncert:

TPU:

14.2 Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

7.13

+/-0.710

+/-0.710 0.468

+/-0.0892

+/-0.0892 U

-0.00779

+/-0.0154

+/-0.0154 0.186

+/-0.0412

+/-0.0412 U

0.743

+/-0.554

+/-0.554 24.4

+/-1.27

+/-1.27 U

-0.111

+/-1.11

+/-1.11 U

0.247

+/-0.204

+/-0.204 U

0.0584

+/-0.143

+/-0.143 9.67

+/-0.437

+/-0.437 14.6

+/-0.633

+/-0.633 U

0.219

+/-0.293

+/-0.293 U

-0.0828

+/-0.303

+/-0.303 U

0.164

+/-0.307

+/-0.307 U

0.0745

+/-0.163

+/-0.163 U

0.247

+/-0.350 pCi/g 6

pCi/g 6

pCi/g 4430 pCi/g 2

pCi/g pCi/g pci/g pci/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pci/g 10/25/06 07:15 (0% - 20%)

(0% - 100%)

(0%- 100%)

(0% - 100%)

104 (75%-125%)

101 (75%-125%)

102 (75%-125%)

Lead-212 Lead-214 18

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174341 Page 3 of 5 Parmname NOM Sample Qual QC Units RPD%

REC%

Range Anist Date Time Rad Gamma Spec Batch 581675 TPU:

Manganese-54 Niobium-94 Potassium-40 Radium-226 Silver-108m Thallium-208 QC1201213157 Actinium-228 Ameridium-241 MB Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

Uncert:

TPU:

+/-0.350 U

0.00541

+/-0.137

+/-0.137 U

-0.0757

+/-0.111

+/-0.111 U

-0.178

+/-0.986

+/-0.986 U

0.247

+/-0.204

+/-0.204 U

0.0371

+/-0.113

+/-0.113 U

0.0403

+/-0.114

+/-0.114 U

0.0547

+/-0.0339

+/-0.0339 U

0.035

+/-0.0503

+/-0.0503 U

0.0861

+/-0.0721

+/-0.0721 U

0.0234

+/-0.0389

+/-0.0389 U

0.00174

+/-0.00859

+/-0.00859 U

-0.00489

+/-0.00879

+/-0.00879 U

-0.00292

+/-0.00844

+1-0.00844 U

-0.0124

+/-0.0226

+/-0.0226 U

-0.0125

+/-0.0235

+/-0.0235 U

'-0.00752 pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g pCi/g (75%-125%)

10/25/06 10:33 Bismuth-212 Bismuth-214 Cesium-134 Cesium-137 Cobalt-60 Europium-152 Europium-154 Europium-155 19

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174341 Page 4 of 5 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Rad Gamma Spec Batch 581675 Uncert:

+/-0.027 TPU:

+/-0.027 Lead-212 U

0.00708 pCi/g Uncert:

+/-0.0292 TPU:

+/-0.0292 Lead-214 U

0.0307 pCi/g Uncert:

+/-0.032 TPU:

+/-0.032 Manganese-54 U

-0.003 pCi/g Uncert:

+/-0.00927 TPU:

+/-0.00927 Niobium-94 U

0.0088 pCi/g Uncert:

+/-0.00881 TPU:

+/-0.00881 Potassium-40 Ul 0.00 pCi/g Uncert:

+/-0.169 TPU:

+/-0.169 Radium-226 U

0.0234 pCi/g Uncert:

+/-0.0389 TPU:

+/-0.0389 Silver-108m U

-0.00204 pCi/g Uncert:

+/-0.00779 TPU:

+/-0.00779 Thallium-208 U

0.00488 pCi/g Uncert:

+/-0.0168 TPU:

+/-0.0168 Notes:

The Qualifiers in this report are defined as follows:

A quality control analyte recovery is outside of specified acceptance criteria Result is less than value reported Result is greater than value reported A

The TIC is a suspected aldol-condensation product B

Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C

Analyte has been confirmed by GC/MS analysis D

Results are reported from a diluted aliquot of the sample H

Analytical holding time was exceeded J

Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R

Sample results are rejected U

Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.

UI Gamma Spectroscopy--Uncertain identification X

Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier 20

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder:

174341 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD%

REC%

Range AnIst Date Time Y

QC Samples were not spiked with this compound A

RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h

Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

21

CENTRAL PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 4 (DQA RESULTS)

CENTRAL-PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 4A (PRELIMINARY DATA REVIEW)

PRELIMINARY DATA REVIEW FORM Survey Unit:

Survey Unit Name:

Classification Survey Media:

Type of Survey:

Type of Measurement:

[umber of Measurements :

9520-0002 Southwest Site Storage area 2

Soil Final Status Survey Radionuclide Specific 15 BASIC STATISTICAL QUANTITIES Cs-137 Target Level (pCi/g):

5.3 8E+00 Minimum Value:

0.OOE+00 Maximum Value:

3.30E-01 Mean :

1.03E-01 Median:

9.08E-02 Standard Deviation :

8.16E-02 Sample Identification 9520-0002-001F 9520-0002-002F 9520-0002-003F 9520-0002-004F 9520-0002-005F 9520-0002-006F 9520-0002-007F 9520-0002-008F 9520-0002-009F 9520-0002-01OF 9520-0002-01F 9520-0002-012F 9520-0002-013F 9520-0002-014F 9520-0002-015F Reported Results Cs-137 Concentration (pCi/g) 3.86E-02 9.53E-02 3.16E-02 1.13E-01 0.OOE+00 5.30E-02 1.16E-01 8.01E-02 8.34E-02 4.16E-02 9.08E-02 3.30E-01 2.03E-01 9.68E-02 1.67E-01 Fraction of Target Detect?

Level 0.007

+

0.018

+

0.006

+

0.021 0.000

+

0.010

+

0.022

+

0.015

+

0.016

+

0.008

+

0.017

+

0.061

+

0.038

+

0.018

+

0.031 Submitted by/DateJ 1 of 1

CENTRAL PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 4B (GRAPHICAL REPRESENTATION OF DATA)

FREQUENCY PLOT FOR CESIUM-137 Survey Unit: 9520-0002 Survey Unit Name: Southwest Site Storage Area Mean: 1.03E-01 pCi/g Frequency Plot For Cs-137 10 U.

8-6-

4-2 0

1.65E-01 2.48E-01 3.30E-01 0.OOE+00 3.25E-02 Upper End Value (pCilg)

Upper End Observation Observation Value Frequency Frequency 0.OOE+00 1

7%

8.25E-02 5

33%

1.65E-01 6

40%

2.48E-01 2

13%

3.30E-01 1

7%

Total:

15 100%

Submitted by/Date Rev wed by ate 1 of 1

QUANTILE PLOT FOR CESIUM-137 Survey Unit:

Survey Unit Name:

9520-0002 Southwest Site Storage Area Mean:

1.03E-01 pCi/g Quantile Plot For Cs-137 3.50E-01 3.O0E-01 2.50E-01 0

24 80100 Percentage Cs-137 Rank Percentage 0.OOE+00 1

3%

3.16E-02 2

10%

3.86E-02 3

17%

4.16E-02 4

23%

5.30E-02 5

30%

8.01E-02 6

37%

8.34E-02 7

43%

9.08E-02 8

50%

9.53E-02 9

57%

9.68E-02 10 63%

1.13E-01 11 70%

1.16E-01 12 77%

1.67E-01 13 83%

2.03E-01 14 90%

3.30E-01 15 97%

Submitted by/Date4/

J ReviewedOby/Date

CENTRAL PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 4C (SIGN TEST)

Connecticut Yankee Decommissioning Project Health Physics Procedure GPP-GGGR-R5121-001 Attachment A, Rev CY-001 MAJOR Sign Test Calculation Sheet For A Single Radionuclide or Gross Activity Measurements Survey Area Number: 9520 Survey Unit Number: 0002 Survey Area Name: Southwest Site Storage Area WPIR#: 2006-0038 Classification: 2 Type I (cc error): 0.05 (N): 15 Radionuclide: Cs-137 DCGL: 5.38 Results (pCi/g)

DCGL - Results Sign 3.86E-02 5.34E+00 I

9.53E-02 5.28E+00 I

3.16E-02 5.35E+00 1

1.13E-01 5.27E+00 I

0.OOE+00 5.3 8E+00 1

5.30E-02 5.33E+00 1

1.16E-01 5.26E+00 I

8.01E-02 5.30E+00 1

8.34E-02 5.30E+00 I

4.16E-02 5.34E+00 I

9.08E-02 5.29E+00 1

3.30E-01 5.05E+00 I

2.03E-01 5.18E+00 1

9.68E-02 5.28E+00 I

1.67E-01 5.21E+00 1

Number of positive differences (S+): 15 Critical Value: 11 Performed by:

Survey Unit Meets Acceptance Criterion Date:

I//r Date:

fl[/016 Page 1 of 1

CENTRAL PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 4D (QC SPLIT RESULTS)

Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A HelhPyisPoeue246-0-P-GRR 400-e.Y00Atcmn Split Sample Assessment Form Survey Area#: 9520 Survey Unit #: 0002 Survey Unit name: Southwest Site Storage Area Sample Plan or WPIR#: 2005-0038 SML#: 9520-0002-011 Sample

Description:

Comparison of split samples collected from sample measurement location #11 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9520-0002-011 F, the comparison sample was 9520-0002-011 FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)

K-40 11.1 6.7E-1 16 0.75-1.33 10.2 4.05E-1 0.92 Y

Comments/Corrective Actions: Not enough Cs-137 to yield an acceptable Resolution Table is provided to show acceptance criteria used to assess split samples.

Resolution 4-7 8-15 16 -50 51 -200

>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80 - 1.25 0.85-1.18 Page 1 of 1

Health Physics Procedure 24265-000-GPP-GGGR-R5124-000-Rev.CY-000 Attachment A HelhPyisPoeue22500GPGG-512-0-e.Y00Atcmn Split Sample Assessment Form Survey Area#: 9520 Survey Unit #: 0002 Survey Unit name: Southwest Site Storage Area Sample Plan or WPIR#: 2005-0038 SML#: 9520-0002-012 Sample

Description:

Comparison of split samples collected from sample measurement location #12 and analyzed using gamma spectroscopy by off-site Vendor Laboratory. The standard sample was 9520-0002-012F, the comparison sample was 9520-0002-012FS.

STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable Value Error Range Value Error Ratio (Y/N)

Cs-137 3.3E-1 1.78E-2 18 0.75-1.33 3.5E-1 2.21E-2 1.06 Y

4

+

t I

1-1 4

+

t t

I I

Comments/Corrective Actions: N/A Table is provided to show acceptance criteria used to assess split samples.

Resolufon 4-7 8-15 16-50 51 -200

>200 Agreement Range 0.5 -2.0 0.6 - 1.66 0.75 - 1.33 0.80 - 1.25 0.85 -1.18 Page 1 of 1

CENTRAL PENINSULA SURVEY UNIT 9520-0002 RELEASE RECORD ATTACHMENT 4E (COMPASS DQA WITH POWER CURVE)

DQA Surface Soil Report Assessment Summary Site:

Planner(s):

Survey Unit Name:

Report Number:

Survey Unit Samples:

Reference Area Samples:

Test Performed:

Judgmental Samples:

Assessment

Conclusion:

9520-0002 FSS McCarthy Southwest Site Storage Area 1

15 0

Sign Test Result:

Not Performed 0

EMC Result:

Not Performed Reject Null Hypothesis (Survey Unit PASSES)

Retrospective Power Curve S0.9

,0.7

. 0.6

  • 0.5 S0.4

,*0.3 0.2 d 0.1

  • -0 Azz 0

1 2

3 4

5 Soil Concentration (p Ci/g), including background

' = Prospective Power U

1-beta Actual Power LBGR Estimated Power DCGL Retrospective Power 6

COMPASS vl.0.0

¶ 21412006 Page 1 COMPASS v1.0.0 12/4/2006 Page 1

DQA Surface Soil Report Survey Unit Data NOTE:

Type = "S" indicates survey unit sample.

Type = "R" indicates reference area sample.

Sample Number 9520-0002-001 F 9520-0002-002F 9520-0002-003F 9520-0002-004F 9520-0002-005F 9520-0002-006F 9520-0002-007F 9520-0002-008F 9520-0002-009F 9520-0002-01OF 9520-0002-011 F 9520-0002-012F 9520-0002-013F 9520-0002-014F 9520-0002-015F Type S

S S

S S

S S

S S

S S

S S

S S

Cs-137 (pCi/g) 0.04 0.1 0.03 0.11 0

0.05 0.12 0.08 0.08 0.04 0.09 0.33 0.2 0.1 0.17 Basic Statistical Quantities Summary Statistic Survey Unit

Background

DQO Results Sample Number Mean (pCi/g)

Median (pCi/g)

Std Dev (pCi/g)

High Value (pCi/g)

Low Value (pCi/g) 15 0.10 0.09 0.08 0.33 0.00 N/A N/A N/A N/A N/A N/A N=15 0.06 N/A 0.0373 N/A N/A COMPASS vl.O.O I 2/4/2006 Page 2 COMPASS vI.0.0 12/42006 Page 2