River Bend Station 2004 Regulatory Guide 1.21 April 19, 2004 ATTACHMENT 1 OFFSITE DOSE CALCULATION MANUAL (ODCM) 66

INFORMATION USE

  • G12.1.17 w_

ENTERGY RIVER BEND STATION STATION OPERATING MANUAL

  • RADIATION SECTION PROCEDURE
  • OFFSITE DOSE CALCULATIONMANUAL (ODCM)

PROCEDURE NUMBER:

  • RSP-0008 REVISION NUMBER:
  • 13 Effective Date:
  • 11-17-05 NOTE: SIGNATURES ARE ON FILE.

TemRev 2 AddCounter 110 Aft Enc DS MSet REGULAR KWN OFF INFORMATION USE

  • INDEXING INFORMATION

INFORMATION USE TABLE OF CHANGES LETTER DESIGNATION DETAILED DESCRIPTION OF CHANGES TRACKING NUMBER

75 10ECLi GPM f=75 GPM. For FL > 0.3, other administrative controls should be implemented to ensure discharges shall not exceed Technical Requirement limits.

__+

Ci FL If (1E c) 7.2.2.1-1 RSP-0008 REV-13 PAGE 10 OF 104

INFORMATION USE Where:fi <

660 C -0.3 E(I OECLEi FL = The fraction of Technical Requirement limits resulting from the release source being discharged fi

= The undiluted release rate at monitor location, in gpm f2

= The cooling tower blowdown release rate, in gpm Ci

= The undiluted concentration of nuclide (i), in pCi/ml from sample assay.

(I OECL)1 = Ten times the Effluent Concentration Limit of nuclide (i) from, in iACi/ml As long as FL is less than 1.0, the concentration of the tank is within compliance with TLCO 3.11.1.1 limits.

2.

Simplified Approach For purposes of simplifying the calculations, the value of 1 x 10-8 tCi/ml (unidentified 10CFR20 ECL value) could be substituted for (ECL)i and the cumulative concentration (C-Total = sum of all identified radionuclide concentrations) or the gross beta-gamma concentration should be substituted for C1. As long as the diluted concentration (C-Total x fi/(f1 +

f2)) is less than 1 x 10-8 ttCi/ml, the nuclide by nuclide calculation is not required to demonstrate compliance with 1 OCFR20 ECL limits.

7.3 Determination of Setpoints for Radioactive Liquid Effluent Monitors 7.3.1.

Requirements Technical Requirements 3.3.11.2 requires the radioactive liquid effluent monitor be operable with their high alarm/trip setpoints set to ensure that limits of Technical Requirements 3.11.1.1 are not exceeded.

The high alarm/trip setpoints shall be determined and adjusted by the methodology which follows:

The high alarm setpoint for the liquid effluent radiation monitor is derived from ten times the concentration limit provided in 10CFR20, Appendix B, Table 2, Column 2 applied at the restricted area boundary where the discharge flows into the Mississippi River.

RSP-0008 REV-13 PAGE 11 OF 104

INFORMATION USE Liquid Monitor Setpoints calculated in accordance with the methodology presented in this section will be regarded as upper bounds for the actual high alarm setpoints. That is, a lower high alarm setpoint may be established on the monitor, if desired.

Alert level setpoints should be established at an appropriate level to give sufficient warning prior to reaching the high alarm setpoint.

1. Liquid Effluent Monitor A General Atomics liquid monitor (radwaste effluent RMS-RE107) equipped with a RD-53 detector with sufficient range (10' to 107 cpm) is provided to ensure compliance with Technical Requirements limits for liquid releases.

The RD-53 is an offline gamma scintillation (NaI) detector designed for detecting radioactivity in liquids.

The monitor consists of a removable sample canister surrounded by Pb shielding. A well inside the canister holds the detector within the sample fluid 7.3.2.

Methodology The high alarm setpoint does not consider dilution, dispersion, or decay of radioactive material beyond the site boundary. That is, the alarm setpoint is based on a concentration limit at the end of the blowdown line.

1. Liquid Radwaste Effluent Monitor (RMS-RE 107)

A sample of each batch of liquid radwaste is analyzed for 1-131 and other principal gamma emitters as specified in Table 3.11.1.1-1 of Technical Requirements 3.11.1.1, for total activity concentration prior to release.

The fraction, FL, of the TLCO 3.11.1.1 limits for unrestricted areas is determined in accordance with the preceding section for the activity concentration released.

NOTE A change to the ODCM may cause a deviation from methodologies used in implementingprocedures (i.e., CSP-01IO). Any change to RSP-0008 shall have an independent Review from Chemistry, as a minimum, to ensure ODCM methodology compliance.

The liquid radwaste effluent monitor will terminate a liquid radwaste discharge if activity levels exceed the Technical Requirements limits. The automatic actions associated with a trip of the monitor are:

1. LWS-AOV257 closes
2.

LWS-AOV258 opens An alarm will also be annunciated in the main control room.

RSP-0008 REV-13 PAGE 12 OF 104

INFORMATION USE The liquid radwaste effluent line radiation monitor alarm setpoint is determined with the equation:

S = -

xgxM 7.3.2.1-1 FL Where:

S

= the radiation monitor setpoint (cpm or pCi/ml)

A

= the sum of concentrations of gamma-emitting radionuclides in the sample, as measured in the laboratory.

FL

= the fraction of TLCO 3.11.1.1 limits resulting from the release source being discharged.

g

= "Instrument Correction Factor"; the ratio of effluent radiation monitor counting rate to laboratory counting rate or activity concentration in a given batch of liquid (cpm per cpm/ml, cpm per pCi/ml, or jiCi/ml per pLCi/ml)

M

= Setpoint Adjustment Factor - error associated with monitor accuracy NOTE A/FL represents the counting rate of a liquid waste stream that would have the same radionuclide distribution as the given batch, but that would produce a concentration of 10 ECL at the point of discharge into the Unrestricted Area NOTE A background determination should be performed prior to each release.

Background subtraction may be performed in accordance with the applicable Chemistry procedures.

7.3.3.

Zero Gamma Activity 1.

For batches with no gamma activity, the requirements of TR 3.11. 1.1 are 15 automatically met for those isotopes. However, with no gamma activity, l l then the monitor setpoint is based solely on beta emitters, which RMS-RE107 does not respond to and the ODCM setpoint calculation in equation 7.3.2.1-1 will not work.

RSP-0008 REV - 13 PAGE 13 OF 104 RSP-0008 REV-13 PAGEI3OFIO4

INFORMATION USE

2.

A default gamma concentration based on LLD values for the isotopes in TR Table 3.11.1.1 and listed in Attachment 2 will be administratively determined and controlled. For this approach, the g Factor should initially be set to 1.0 and adjusted as necessary to allow liquid discharges. This methodology also assumes that H-3 will not exceed 100 times the ECL fraction and that other beta emitters will not exceed 10 times the ECL fraction. The discharges using this method will still meet the 10CFR20 limits.

7.4 Determining the Dose for Radioactive Liquid Effluents 7.4.1.

Requirements Technical Requirements 3.11.1.2 requires the dose or dose commitment to a member of the public from radioactive material released in liquid effluents be determined on a cumulative basis at least every 31 days. Dose or dose commitment shall be limited to:

1. Less than or equal to 1.5 mrem to the total body and to less than or equal to 5 mrem to any organ, during any calendar quarter; and
2.

Less than or equal to 3 mrem to the total body and less than or equal to 10 mrem to any organ during any calendar year.

7.4.2.

Methodology This section provides the methodology to calculate dose to all age groups and organs from all radionuclides identified in the liquid effluents.

The method is based on the methodology suggested by Sections 4.3 and 4.3.1 of NUREG-0133, Rev. 1, November 1978. The dose factors Ai, for all viable pathways are listed in Attachment 3.

The following equation provides a dose calculation to the total body or any organ for a given age group based on actual release conditions.

Air*t*Q4 7.4.2-1 DF*D DTOTALI Dir 7.4.2-2 i=1 Where:

DTOTAL,

=

The total dose commitment to the organ (T) due to all releases during the desired time period in mrem.

RSP-0008 REV-13 PAGE 14 OF 104

INFORMATION USE Di, =

Dose commitment from radionuclide (i) received by organ (C) of the adult age group during the time period (mrem).

Ai, =

Site related dose commitment factor to the total body or any organ (T) for each identified radionuclide (i). The Ai. values listed in are site-related to RBS (mrem/hr per JLCi/ml).

At =

The total time for all batch releases that occurred in the period (hrs).

Qi =

The total quantity of nuclide (i) released during the interval At (PCi).

Dw =

The near field dilution factor. Site specific value is 136.

DF =

The total volume of dilution that occurred during the time period (ml).

The doses associated with each isotope may then be summed to provide the cumulative dose over a desired time period (e.g., sum all doses during a 31 day period, calendar quarter, or a year).

7.5 Projecting Dose for Radioactive Liquid Effluents 7.5.1.

Requirements Technical Requirement 3.11.1.3 requires the liquid radwaste treatment system be used to reduce the radioactive materials in liquid wastes prior to their discharge when projected doses due to liquid effluents, to unrestricted areas (Figure 1) would exceed 0.06 mrem to the total body or 0.2 mrem to any organ in a 31 day period.

7.5.2.

Methodology The following calculational methodology shall be performed at least once per 31 day period:

LP =DTOTALr

  • 3 1*3+D 7.5.2-1 XD DTOTAL, =The total dose commitment to the organ ('r) due to all releases during the desired time period.

LPD =

Projected dose commitment (mrem) to organ (T) during the 31 day period from liquid effluents.

XD =

Number of days to date in the current quarter RSP-0008 REV - 13 PAGE IS OF 104 RSP-0008 REV-13 PAGE15OF1O4

INFORMATION USE DPA=

The anticipated dose contribution to the total body or any organ X, due to planned activities during the next 31 day period, if those activities will result in liquid releases that are in addition to routine liquid effluents. If only routine liquid effluents are anticipated, DPA

=0.

8 GASEOUS EFFLUENT METHODOLOGY 8.1 Introduction River Bend Station discharges gaseous effluents through the Main Plant Exhaust Duct, Fuel Building Exhaust Duct, and Radwaste Building Exhaust Duct. The location of these release points in relation to the River Bend site is found in Figure 3. The gaseous effluent streams, radioactivity monitoring points, and effluent discharge points are shown schematically in Figure

2. All gaseous effluent releases from the Radwaste Building Exhaust Duct and Fuel Building Exhaust Duct are assumed to be ground level releases. The Main Plant Exhaust Duct routine releases are treated as a wake split (conditionally elevated) release.

8.2 Data Requirements for Gaseous Effluents For the purpose of estimating offsite radionuclide concentrations and radiation doses, measured radionuclide concentrations in gaseous effluents and in ventilation air exhausted from the station are used. Table 3.11.2.1-1 in the Technical Requirements identifies the radionuclides in gaseous discharges for which sampling and analysis is done.

Historical annual average meteorological information will be used to calculate off-site dose and monitor set points. Modeling will be performed in accordance with the methodologies described in Reg. Guide 1.111 Rev. 1.

8.3 Instantaneous Release Rate and Setpoint Determination 8.3.1.

Instantaneous Release Rate Determination The instantaneous release rate determination is performed to show compliance with the limits set forth in the TRM.

1. Requirements Technical Requirements 3.11.2.1 states that the dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the site boundary (see Figure 1) shall be limited to the following:
1. For noble gases: Less than or equal to 500 mrem/year to the total body and less than or equal to 3,000 mrem/year to the skin; and RSP-0008 REV-13 PAGE 16 OF 104

INFORMATION USE

2.

For I-131, 1-133, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days: less than or equal to 1,500 mrem/year to any organ.

2. Methodology
1. Total Body and Skin Instantaneous Dose Rate Calculations To determine the dose rate from noble gases in unrestricted areas, the following formulae are used:

n DRTB = Y(Kj)(Xl Q)(Q;)

8.3.1.2.1-1 i=

n DRsKN =(Li

+1. lMj) (X /Q) (Q) 8.3.1.2.1-2 1=1 Where:

DR sKwu Dose rate to the skin in mrem/year DR TB = Dose rate to the total body in mrem/year K = The total body dose factor due to gamma emissions for each identified noble gas radionuclide (i) in mrem/yr per ACi/M3 L

Skin dose factor due to beta emissions for each identified noble gas radionuclide (i) in mrem/yr per pCi/M3 Attachment 4 M = The air dose factor due to gamma emissions for each identified noble gas radionuclide (i) in mrad/yr per gCi/M 3 Attachment 4 XAQ =The highest calculated annual average relative dispersion factor for any area at or beyond the unrestricted area boundary for all Sectors (sec/M3). Attachment 9 Q= The release rate of radionuclide (i) in gaseous effluents from all releases in pCi/sec 1.1 = Conversion factor for Mi from mrad to mrem RSP-0008 REV-13 PAGE 17 OF 104

INFORMATION USE In order to comply with the limits of the TRM, DRTB <500 mrem/year and DRskin 53,000 mrem/year must be met at the most limiting location, at or beyond the site boundary.

The (x/Q) values utilized in equations 8.3.1.2.1-1 and 8.3.1.2.1-2 are based upon maximum long-term annual average (x Q) in the unrestricted area. Attachment 9 lists the maximum (x /Q) values for the RBS release points at the appropriate receptor locations.

To select the most limiting location, the highest (x ) for each release point is used (from Attachment 9):

(XIQ),W 3.31 x 10-6 sec/M3 (X/Q)GRD 4.21 x 10-5 sec/i 3 where:

(x Q)Q = Chi/Q for Main Plant exhaust duct (mixed mode)

X/Q)GCRD = Chi/Q for Radwaste Building exhaust duct (ground level) and for Fuel Building exhaust duct (ground level)

(Attachment 9 contains the maximum X/Q) and D/Q values used in calculating individual doses.)

Release rates for all release points must be considered at the same time.

If releases are occurring at the same time, the total instantaneous dose for all releases must be less than the limits of Technical Requirements 3.11.2.1. An administrative control limits the release rates for each of the three release points to 1/3 the total Technical Requirements doses.

2.

Radioiodine, Tritium, and 8-day Particulate Dose Rate Calculations The following calculational method is provided for determining the dose rate from radioiodine (I-131, 1-133), Tritium and particulates with half-lives greater than 8 days and to determine if they are within the limits listed in Section 8.3.1.1.2.

RSP-0008 REV-13 PAGE 18 OF 104

INFORMATION USE In the calculation to show compliance with the TRM, only the inhalation pathway is considered, since it is the most limiting pathway.

Inhalation Pathway:

DRI&8DPr = E Pi (X / QtQi 8.3.1.2.2-1 n=1 where:

DRI&SDPr = Dose rate to the organ X for the age group of interest from radioiodines (I-131 and 1-133), tritium and 8 day particulates via the inhalation pathway (mrem/yr).

= Release rate of nuclide (i), (pCi/sec).

(x IQ)

= The highest calculated annual average relative dispersion factor for any area at or beyond the unrestricted area boundary for all sectors (sec/M3). Attachment 9.

P, = The dose factor for applicable environmental pathway (mrem/yr per juCi/m3). Attachment 15 through Attachment 18.

Values for Pi were calculated for all age groups using the inhalation pathway methodology of NUREG-0133.

8.3.2.

Setpoint Determination

1. Requirements Instrumentation is provided to monitor beta-gamma radiation from radioactive materials released from the River Bend Station in gaseous effluents. Each release point process monitor listed in the TRM includes an alarm (HIGH ALARM) that is set to report when the radioactive noble gas in gaseous effluents (Main Plant exhaust duct, Fuel Building exhaust duct and/or Radwaste Building exhaust duct) is expected to cause a noble gas concentration at ground level offsite resulting in a dose rate equal to or greater than 500 mrem/yr to the total body and/or 3000 mrem/yr to the skin.

RSP-0008 REV - 13 PAGE 19 OF 104 RSP-0008 REV-13 PAGE19OF1O4

INFORMATION USE The ALERT alarm is set to report when the radioactive noble gas in gaseous effluents (Main Plant exhaust duct, Fuel Building exhaust duct and/or Radwaste Building exhaust duct) is expected to cause a noble gas concentration at ground level offsite that would result in meeting or exceeding either the 5 mrad per quarter gamma air dose or 10 mrad per quarter beta air dose limit (Technical Requirements 3.11.2.2).

It is permissible to set the ALERT alarm at twice (2.0) normal (approximately 100 % unit power) detector background if nuisance alarms would result from setpoints based on gamma and beta air dose.

The distribution of radioactive noble gases in a gaseous effluent stream is determined by gamma spectrum analysis of identifiable radionuclides in effluent gas sample(s). Results of one or more previous analyses may be averaged to obtain a representative sample. In the event the distribution is unobtainable from measured data, the distribution of radioactive noble gases based on past data or calculated by the BWR-GALE code may be used.

To allow for multiple sources of releases from the three different release points, the allowable operating setpoints will be administratively controlled to allocate one-third (1/3) of the total allowable release to each of the release sources.

2.

Methodology

1. HIGH ALARM Setpoint Determination This section describes the methodology for determining and adjusting HIGH ALARM setpoints for the three release points:

a Wide Range Gas Monitor (WRGM)

Step 1. Determine QTB as follows:

QTB (500) 8.3.2.2-1 I=1 where:

QTB= maximum acceptable total release rate of all noble gas radionuclides in the gaseous effluent (pLCi/sec).

RSP-0008 REV-13 PAGE 20 OF 104

INFORMATION USE XIQ) = The highest calculated annual average relative dispersion factor for any area at or beyond the unrestricted area boundary for all Sectors (sec/M3).

Ki = The total whole body dose factor due to gamma emissions from noble gas radionuclide (i) mrem/yr per p.Ci/m3) from Attachment 4.

fi= Fraction of noble gas radionuclide (i) to total noble gas concentration.

500 = Whole body exposure limits of 500 mrem/year.

Step 2. Determine Qs as follows:

QS =

(3000) 8.3.2.2-2 (X/ -Q) [(ii + 1. IlMj I j=1 where:

Qs = the maximum acceptable release rate of all gas radionuclides in the gaseous effluent [ptCi/sec]

Li + 1.1 Mi = Calculated total skin dose factor due to emission from noble gas radionuclide (i) mrem/yr/4Ci/m3 from.

fi= Fraction of noble gas radionuclide (i) to total noble gas concentration (X/Q) = The highest calculated annual average relative dispersion factor for any area at or beyond the unrestricted area boundary for all Sectors (sec/r 3), Attachment 9.

3000 = Skin exposure limit of 3000 mrem/year Step 3. Select the lower of the Q values (QTB or Qs) obtained in Step I and Step 2.

RSP-0008 REV-13 PAGE 21 OF 104

INFORMATION USE NOTE Actual alarm setpoint in the data base may be modified to accountfor loop accuracy.

Step 4. Multiply the Q value selected in Step 3 by 0.33.

By multiplying the Q value by a factor of 0.33, the allowable operating setpoints will be administratively controlled to allocate one-third (1/3) of the total allowable release rate to each of the release points. The resultant product will be the actual ODCM release rate HIGH ALARM setpoint for the appropriate WRGM Monitor.

b Particulate and Gas Monitor (P&G) (gas channel only).

Step 1. Perform Steps 1 through 3 of Section 8.3.2.2.1.a above.

Step 2. Determine Cm (the maximum acceptable total radioactivity concentration of all noble gas radionuclides for all release points in the gaseous effluent [,lCi/cc]):

C. =(2.12xl0-3) Q 8.3.2.2-3 F

where:

2.12 x 10-3= Unit conversion factor to convert IlCi/sec/cfin to tICi/cc Q = Lower of the two Q values, QTB or Qs F =The maximum acceptable effluent flow rate at the point of release based on design flow rates (cfm)

NOTE Actual alarm setpoint in the database may be modified to accountfor loop accuracy.

Step 3. Multiply the Cm value determined in Step 2 by 0.33. By multiplying the Cm value by a factor of 0.33, the allowable operating setpoints will be administratively controlled to allocate one-third (1/3) of the total allowable release to each of the release points. The resultant product will be the actual ODCM activity concentration HIGH ALARM setpoint for the appropriate P&G monitor gas channel.

RSP-0008 REV-13 PAGE 22 OF 104

INFORMATION USE

2.

ALERT Setpoint Determination (Reference 2.6)

This section describes the methodology for determining and adjusting ALERT setpoints for the three release points.

a Wide Range Gas Monitor (WRGM)

Step 1. Determine QG-A utilizing one of the following methods:

QG-A (4X) 8.3.2.2-4 (X/Q)M if, i=1 where:

QG-A = The maximum acceptable total release rate of all noble gas radionuclides in the gaseous effluent [ACilsec]

(X Q) = The highest calculated annual average relative dispersion factor for any area at or beyond the unrestricted area boundary for all Sectors (sec/M3),

5 = 5 mrads/quarter gamma air dose limit at the unrestricted area boundary Mi = The gamma air dose factor for radioactive noble gas nuclide (i) in mrad-m3/gCi-yr, Attachment 4 f= The fractional abundance of noble gas radionuclide i 4

Number of Quarters Per Year Step 2. Determine QB-A utilizing one of following methods:

Q

=

(4XI °)

8.3.2.2-5 (X -I N, f, Where:

QB-A = maximum acceptable total release rate of all noble gas radionuclides in the gaseous effluents.LCi/sec)

RSP-0008 RE

-13 PAE 3 F 0 RSP-0008 REV-13 PAGE23OF1O4

INFORMATION USE (X )Q = The highest calculated annual average relative dispersion factor for an area at or beyond the unrestricted area boundary for all sectors (sec/m ), Attachment 9 10 = 10 mrad/quarter (92 days) beta air dose limit at the unrestricted area boundary Ni = The air dose factor due to beta emissions from each noble gas radionuclide (i) in Attachment 4 f = The fractional abundance of noble gas radionuclide i 4 = Number of Quarters Per Year Step 3. Select the lower of the Q values obtained in Steps 1 and 2, either QG-A or QB-A-Step 4. Multiply the Q value selected in Step 3 by 0.33. By multiplying the Q value by this factor, the allowable operating setpoints will be administratively controlled to allocate one-third (1/3) of the total allowable release rate to each of the release points. The resultant product will be the actual ODCM ALERT setpoint to be entered into the applicable WRGMs RM-80.

Step 5. If the actual ODCM ALERT setpoint determined in Step 4 is less than two times (2.0) the detector background, it is permissible to enter an ALERT setpoint equal to two times (2.0) the normal (approximately 100%

unit power) detector background to reduce the possibility of nuisance alarms. The twice background setpoint should provide sufficient indication that an offsite dose limit could possibly be exceeded.

b Particulate and Gas Monitor (P&G) (gas channel only)

Step 1. Perform Steps 1 through 3 of Section 8.3.2.2.2.a above.

Step 2. Determine Cm (the maximum acceptable total radioactivity concentration of all noble gas radionuclides for all release points in gaseous effluent [pCi/cc]):

C (2.12 x l 0-3)Q 8.3.2.2-6 F

Where:

2.12 x 10-3 = Unit conversion factor to convert pCi/sec/cfm to Rci/cc.

RSP-0008 REV-13 PAGE 24 OF 104

INFORMATION USE Q = Lower of the two Q values, QG-A or QB-A F = The maximum acceptable effluent flow rate at the point of release based on design flow rates (cfm).

Step 3. Multiply the Cm value determined in Step 2 by 0.33. By multiplying the Cm value by this factor, the allowable operating setpoints will be administratively controlled to allocate (1/3) of the total allowable release to each of the release points. The resultant product will be the actual ODCM activity concentration ALERT setpoint. This value is the setpoint to be entered into the applicable P&G monitor's RM-80.

Step 4. If the actual ODCM ALERT setpoint determined in Step 3 is less than two times (2.0) the gas detector background, it is permissible to enter an ALERT setpoint equal to two times (2.0) the normal (approximately 100% unit power) gas detector background to reduce the possibility of nuisance alarms. The twice background setpoint should provide sufficient indication that an offsite dose limit could possibly be exceeded.

8.4 Cumulative Dose Determination for Radioactive Gaseous Effluents 8.4.1.

Noble Gases

1. Air Dose
1. Requirements Technical Requirements 3.11.2.2 states that the air dose due to noble gases released in gaseous effluents to areas at and beyond the site boundary (see Attachment 34) shall be limited to the following:

a During any calendar quarter: less than or equal to 5 mrads for gamma radiation and less than or equal to 10 mrads for beta radiation; and b

During any calendar year: less than or equal to 10 mrads for gamma radiation and less than or equal to 20 mrads for beta radiation.

2.

Methodology This section provides the methodology to calculate the gamma and beta air doses to a maximum receptor location at the site boundary from all noble gas radionuclides identified in the gaseous effluents.

RSP-0008 REV -13 PAGE 25 OF 104

INFORMATION USE The method is based on the methodology suggested by sections 5.3 and 5.3.1 of NUREG-0133, Rev. 1, November 1978.

The dose factors for beta and gamma air dose are listed in Attachment 4 and are obtained from Table B-I of RG 1.109, Revision 1, October 1977.

The following equations provide for air dose calculations based on actual noble gas releases during a specific time interval for radioactive gaseous release sources at the site boundary:

DGam iAjr =3.17E-8 (M1XX/Q)(Q) 8.4.1.1.2-1 DBeta-Air =3.17E-8 (N) XX QIQ)( )

8.4.1.1.2-2 i=1 where:

D

= The gamma air dose from radioactive noble gases in Gamma-Air mrad.

Mi

=The gamma air dose factor for radioactive noble gas nuclide (i) in mrad-m3/pCi-yr (Attachment 4) 3.17E-8

= Inverse of number of Seconds Per Year in Year/Sec (Xi Q)

= The highest calculated annual average relative dispersion factor for an area at or beyond the unrestricted area boundary for all sectors (sec/M3), Attachment 9 Qi

= The quantity of gCi of nuclide (i) released during the period of interest D

= Beta air dose from radioactive noble gases in mrad Beta-Air N1

= The beta air dose factor for radioactive noble gas nuclide (i) in mrad-m3/ptCi-yr (Attachment 4), Table C-I RSP-0008 REV - 13 PAGE 26 OF 104 RSP-0008 REV-13 PAGE26OF1O4

INFORMATION USE

2.

Total Body and Skin Dose

1. Requirements a

Technical Requirements 3.11.4 states that the annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC, due to releases of radioactivity and to radiation from uranium fuel cycle sources, shall be limited to less than or equal to 25 mrem to the total body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrem.

b Technical Specification 5.5.4.j requires the limitations on the annual dose or dose commitment to any member of the public due to releases of radioactivity and to radiation from uranium fuel cycle sources, conforming to 40 CFR 190.

Cumulative doses from liquid effluents and gaseous pathways (radioiodines (I-131, 1-133), Tritium and particulates with T 1/2

> 8 days) are determined in accordance with Sections 7.4.2 and 8.4.1.3. Cumulative total body and skin doses from noble gas releases are determined in accordance with Section 8.4.1.2.2.

2.

Methodology This section provides the methodology to calculate the total body and skin doses to the likely most-exposed MEMBER OF THE PUBLIC from all noble gas radionuclides identified in the gaseous effluents.

The method is based on the methodology suggested in section C.2 and Appendix B of NRC Regulatory Guide 1.109, revision 1, October 1977 and is used to calculate the doses in this section. The dose transfer factors required for the calculations are listed in Attachment 4 of this document and are obtained from Table B-1 of RG 1.109, Revision 1, October 1977.

Doses to the total body and to the skin, due to actual noble gas releases during a specific time interval, at the location of the likely most exposed MEMBER OF THE PUBLIC, are calculated as follows:

DT.faIBody = (SFXFO X3.17E -8) (K,X /Q)Q) 8.4.1.2.2 -1 Dskll =(FOX3.17E-8) (L+1.lM(SF));txoQk;_)

8.4.1.2.2-2 W=1 Where:

RSP-0008 REV - 13 PAGE 27 OF 104 RSP-0008 REV-13 PAGE27OF1O4

INFORMATION USE DTOtaW BOXy = The total body dose from radioactive noble gases in mrem Ki= The total whole body dose factor due to gamma emissions from noble gas radionuclide (i) (mrem/yr per jRCi/m 3) from, Table C-I (X IQ) = The highest calculated annual average relative dispersion factor for an area at or beyond the unrestricted area boundary for all sectors (sec/M3) (Attachment 9)

NOTE When calculating DTml1lB,,) and Dscn for determining 40CFRJ90 compliance as reported in the Annual Radioactive Effluent Release Report, (iV7Q) values based on either historical annual-average meteorological data, or on data for the actual period of release, may be used.

Qi = The number of pCi of noble gas nuclide (i) released during the period of interest Dskin = The skin dose from radioactive noble gases in mrem Mi = The gamma air dose factor due to gamma emissions from each noble gas radionuclide (i) released Attachment 4, Table C-I Fo = Occupancy factor determined for the receptor at the given location (default= 1.0)

NOTE If a time period is less than one full year, determine the fraction of a year and multiply the fraction by 3.1 7E-8 for use in equations 8.4.1.2.2-1 and -2.

3.17E-8 = Inverse of the number of seconds per year in yr/sec L= The skin dose factor due to beta emissions from noble gas radionuclide (i) (mrem/yr per IiCi/m3) from Attachment 4, Table C-I 1.1 Average ratio of tissue to air energy absorption coefficients SF = 1.0, attenuation factor accounting for shielding provided by residential structures for maximally exposed individual RSP-0008 REV - 13 PAGE 28 OF 104 RSP-0008 REV-13 PAGE28OF1O4

INFORMATION USE

3.

Radioiodine, Tritium, and 8 Day Particulate Dose to Any Organ from Cumulative Releases

1. Requirements a

Technical Requirements 3.11.2.3 states that the dose to a Member of the Public from Radioiodines (1-131, 1-133), Tritium, and Particulates with T1/2> 8 days in gaseous effluents released to areas at and beyond the site boundary shall be limited to the following:

i.

During any calendar quarter: less than or equal to 7.5 mrem to any organ; and ii. During any calendar year: less than or equal to 15 mrem to any organ.

The dose to a member of the Public shall be determined at least once per 31 days for the current calendar quarter and current calendar year.

b Technical Requirement 3.11.4 states that the Annual (Calendar year) dose or dose commitment to any Member of the Public, due to releases of radioactivity and to radiation from Uranium Fuel Cycle sources, shall be limited to less than or equal to 25 mrem to the total body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrem.

2.

Methodology a

The following calculational method is provided for determining the organ dose due to releases of radioiodines (1131, I133),

tritium and particulates. It is based on Section 5.3.1 of NUREG-0133, Rev. 1, November 1978. The equation can be used for any age group provided that the appropriate dose factors are used and the total dose reflects only those pathways that are applicable to the age group. The total dose to an organ can then be determined by summing the pathways that apply to the receptor.

The equations are:

NOTE When calculating organ doses due to the release of C-14 and/or tritium (H-3), (X Q) values, not AQ) values, must be usedfor cow milk, goat milk, meat and vegetation pathway calculations.

Inhalation Pathways:

RSP-0008 REV -13 PAGE 29 OF 104

INFORMATION USE D,&8DP, =(3.1 7x10 XF )E (P. XX /Q)iQ )

8.4.1.3-1 i=1 Ground Plane Pathway:

Dj&$Dp-,=(3.17x10 8XFo) (R,,)kD-QW) 8.4.1.3-2 1=1 Contaminated Forage/Cow/Milk Pathway:

DI&S8DP =(3.17xlO-8XFO) (RikXDQi pi) 8.4.1.3-3 Contaminated Forage/Goat/Milk Pathway:

DI&8DP, =(3.1 7xl 0XF),

(Rjr XQW) 8.4.1.3-4 1=1 Contaminated Forage/Meats:

Dj&8DPr =(3.17xl0(8XFo) (R,,)D/Q)i) 8.4.1.3-5 i=1 Fresh Fruits and Vegetables:

DI& 8DPA

=(3.17x10 8F 0 )n(Rj(D1Q)$)

8.4.1.3-6 i=1 Total Dose:

n D, = D&8DPr 8.4.1.3-7 z=1 Where:

Di&8DP, = Dose to the organ (T) for the age group of interest from radioiodines (I-131, I-133), tritium and 8-day particulates via the pathway of interest FO = Occupancy factor defined for the receptor at the given location D= Total dose in mrem to the organ (') of a specified age group summed over all applicable pathways (Z)

RSP-0008 REV-13 PAGE 30 OF 104

INFORMATION USE z = All the applicable pathways for the age group of interest Pi, = Inhalation dose conversion factor mrem/yr per,Ci/M3 Qi = The number of pCi of nuclide (i) released during the year of interest RET= The dose factor for nuclide (i) for pathway (Z) to organ (T) of the specified age group. For tritium, a site-specific absolute humidity (H) value of 12.9 gm/M3 was used for calculation. (See Attachment 15 through Attachment 33.)

The units are:

mrem - m3 for pathways using XQ)

PCi-yr or mrem - m -sec C

for pathways using (p / Q) pCi-yr (D /Q) = A long-term relative deposition value for elevated and ground level releases (m 2)

(x /Q)

= The highest calculated annual average relative dispersion factor for an area at or beyond the unrestricted area boundary for all sectors (sec/m ), Attachment 9.

3.17X 10-8= The inverse of the number of seconds per year (years/sec).

8.5 Dose Projection - Determination of Need to Operate Ventilation Exhaust Treatment System 8.5.1.

Requirement Technical Requirements 3.11.2.5 requires that the ventilation exhaust treatment system be used to reduce radioactive material in waste prior to discharge when the projected dose due to gaseous effluents (radioiodines (I-131, I-133),

particulates T 1/2 > 8 days and H-3) would exceed 0.3 mrem to any organ in a 31 day period.

RSP-0008 REV - 13 PAGE 31 OF 10Q4 RSP-0008 REV-13 PAGE3I OF 104

INFORMATION USE NOTE The ventilation exhaust treatment system does not reduce the noble gas concentration in plant effluents (See Definition 3.5).

8.5.2.

Methodology The following calculation method is provided for determining the projected doses:

G

=k*31+D 8.5.2-1 PD X

PA D

Where:

GPD = Projected dose due to radioiodines (1-131, 1-133), particulates with T 1/2

> 8 days and H-3 during the current 31 day period (mrem)

XD= The number of days to date in the current quarter D, Cumulative total dose due to radioiodines (I-131, I-133), particulates with T 1/2 > 8 days and H-3 during the current quarter (mrem)

DPA = The anticipated dose contribution to the total body or any organ X due to planned activities during the next 31 day period, if those activities will result in gaseous releases that are in addition to routine gaseous effluents. If only routine effluents are anticipated, DPA = 0. This value may be adjusted to account for any changes in operating conditions that could significantly alter actual releases, such as failed fuel or changes in ventilation flow rate.

A dose projection would be based on the latest results of the monthly calculations of the dose due to radioiodines (1-131, I-133), particulates with T 1/2 > 8 days, and H-3 (Section 8.4.1.3).

9 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM contains the sample point description, sampling and collection frequency, analysis, and analysis frequency for various exposure pathways in the vicinity of RBS for the Radiological Environmental Monitoring Program. Attachment 34 and Attachment 38 indicate the locations of the various onsite and offsite sampling points and TLD locations.

RSP-0008 REV-13 PAGE 32 OF 104

INFORMATION USE This section describes only those elements of the Radiological Environmental Monitoring Program required by the RBS Technical Requirements Manual. Additional exposure pathways, sample points, analyses, and/or frequencies may be performed as described in Reference 2.3 Section 6.2.

Samples of groundwater are taken from onsite wells located to intercept any potential contamination of the Upland Terrace Aquifer so that any such contamination would be detected before migrating beyond RBS site boundaries.

10 40CFR190 CONSIDERATIONS 10.1 Compliance with 40CFR190 Compliance with 40CFR190 as prescribed by Technical Requirements 3.11.4 is to be demonstrated only when one or more of Technical Requirement(s) 3.11.1.2.a, 3.11.1.2.b, 3.11.2.2.a, 3.11.2.2.b, 3.11.2.3a, and 3.11.2.3.b, including direct radiation are exceeded by a factor of 2. Once this occurs, EOI has 30 days to submit a report in accordance with Requirement 3.11.4.

10.2 Calculations Evaluating Conformance with 40CFR190 To perform the calculations to evaluate conformance with 40CFR190, an effort is made to develop doses that are realistic by removing assumptions that lead to overestimates of dose to a Member of the Public (i.e., calculations for compliance with 1 OCFR50 Appendix I). To accomplish this, the following calculational rules are used:

10.2.1.

Doses to Members of the Public via the liquid release pathway are considered to be < I mrem/yr (Ref NUREG-0543).

10.2.2.

Doses to a member of the Public due to a milk pathway will be evaluated only as can be shown to exist. Otherwise, doses via this pathway will be estimated as < 1 mrem/yr.

10.2.3.

Environmental sampling data that demonstrate that no pathway exists may be used to delete a pathway to man from a calculation.

10.2.4.

To sum numbers represented as "less than" (<), use the value of the largest number in the group.

e.g., <5+ <1 + <1 + <3 = <5 10.2.5.

When doses via direct radiation are added to doses via inhalation pathway, they will be calculated for the same distance in the same sector.

10.2.6.

The calculational locations for a Member of the Public will only be at residences or places of employment.

RSP-0008 REV-13 PAGE 33 OF 104

INFORMATION USE NOTE Additional assumptions may be used to provide situation specific parameters, provided they are documented along with their concomitant bases.

NOTE Estimates for each of the calculations below will be made for each of the following exposure pathways to the same location by age class. Only those age classes known to exist at a location are considered 10.3 Calculations of Total Body Dose 10.3.1.

Direct Radiation (from storage tanks, N-16 sources, etc.)

The component of dose to a Member of the Public due to direct radiation will be determined by thermoluminescent dosimeters (TLDs).

10.3.2.

Inhalation Dose The inhalation dose will be determined at the calculational locations for each age group according to the methods outlined in Section 8 of this manual.

10.3.3.

Ingestion Pathway (cow milk, goat milk, meat, vegetation)

The dose via the ingestion pathway will be calculated at the consumer locations for the consumers at risk. If no milk pathway exists in a sector, the dose via this pathway will be treated as < 1 mrem/yr.

10.3.4.

Total Body Noble Gas Immersion Dose This dose will be calculated in accordance with Section 8.4.1.2.2. for the maximally exposed MEMBER OF THE PUBLIC in the limiting sector.

10.3.5.

Ground Plane Deposition 10.3.6.

Other Uranium Fuel Cycle Sources The dose from other fuel sources will be treated as < 1 mrem/yr.

10.4 Thyroid Dose The dose to the thyroid will be calculated for the limiting sector as the sum of:

10.4.1.

Direct Radiation (from storage tanks, N-16 sources, etc.)

RSP-0008 REV -13 PAGE 34 OF 104

INFORMATION USE The component of dose to the thyroid due to direct radiation will be determined by thermoluminescent dosimeters (TLDs).

10.4.2.

Inhalation Dose The inhalation dose to the thyroid will be determined at the calculational locations for each age group according to the methods outlined in Section 8 of this manual.

10.4.3.

Ingestion Pathway (cow milk, goat milk, meat, vegetation)

The dose to the thyroid via the ingestion pathway will be calculated at the consumer locations for the consumers at risk. If no milk pathway exists in a sector, the dose via this pathway will be treated as < 1 mrem/yr.

10.4.4.

Noble Gas Immersion Dose It is assumed that an external total body dose from noble gases irradiates internal body organs at the same numerical rate (Reference 2.8). This dose for the thyroid will therefore be equal to the dose calculated in Step 10.3.4 above.

10.4.5.

Ground Plane Deposition 10.4.6.

Other Uranium Fuel Cycle Sources The dose from other fuel cycle sources will be treated as <1 mrem/yr.

10.5 Organ Dose (other than thyroid and skin)

The dose to any organ will be calculated for the limiting sector as the sum of:

10.5.1.

Direct Radiation (from storage tanks, N-16 sources, etc.)

The component of dose to an organ due to direct radiation will be determined by thermoluminescent dosimeters (TLDs).

10.5.2.

Inhalation Dose The inhalation dose to an organ will be determined at the calculational locations for each age group according to the methods outlined in Section 8 of this manual.

10.5.3.

Ingestion Pathway (cow milk, goat milk, meat, vegetation)

The dose to an organ via the ingestion pathway will be calculated at the consumer locations for the consumers at risk. If no milk pathway exists in a sector, the dose via this pathway will be treated as < I mrem/yr.

RSP-0008 REV -13 PAGE 35 OF 104

INFORMATION USE 10.5.4.

Noble Gas Immersion Dose It is assumed that an external total body dose from noble gases irradiates internal body organs at the same numerical rate (Reference 2.8). This dose for an organ will therefore be equal to the dose calculated in Step 10.3.4 above.

10.5.5.

Ground Plane Deposition 10.5.6.

Other Uranium Fuel Cycle Sources The dose from other fuel cycle sources will be treated as < 1 mremlyr.

10.6 Skin Dose The dose to the skin will be calculated for the limiting sector as the sum of:

10.6.1.

Direct Radiation (from storage tanks, N-16 sources, etc.)

The component of dose to the skin due to direct radiation will be determined by thermoluminescent dosimeters (TLDs).

10.6.2.

Inhalation Dose The inhalation dose to the skin (only tritium is considered) will be determined at the calculational locations for each age group according to the methods outlined in Section 8 of this manual.

10.6.3.

Ingestion Pathway (cow milk, goat milk, meat, vegetation)

The dose to the skin via the ingestion pathway (only tritium and C-14 considered) will be calculated at the consumer locations for the consumers at risk. If no milk pathway exists in a sector, the dose via this pathway will be treated as < 1 mrem/yr.

10.6.4.

Skin Noble Gas Immersion Dose This dose will be calculated in accordance with Section 8.4.1.2.2 for the maximally exposed MEMBER OF THE PUBLIC in the limiting sector(s).

10.6.5.

Ground Plane Deposition 10.6.6.

Other Uranium Fuel Cycle Sources This dose from other fuel cycle sources will be treated as < 1 mrem/yr.

RSP-0008 REV-13 PAGE 36 OF 104

INFORMATION USE 11 INTERLABORATORY COMPARISON STUDIES 11.1 Requirement Technical Requirements 3.12.3 states that analyses shall be performed on radioactive materials, that correspond to samples required by Table 3.12.1-1, supplied as part of an Interlaboratory Comparison Program.

11.2 Program 11.2.1.

Environmental Sample Analyses Comparison Program Environmental samples from the River Bend Station are to be analyzed by the River Bend Station Environmental Services Group or by a qualified contracting laboratory. These laboratories will participate in an Environmental Radioactivity Laboratory Intercomparison Studies (Crosscheck) Program. This participation will include all of the determinations (sample-radionuclide combinations) that are included in the licensee's Radiological Environmental Monitoring Program. Results of the Interlaboratory Program will be included in the Annual Radiological Environmental Operating Report.

11.2.2.

Effluent Release Analyses Program RBS Chemistry Group will perform sample analyses for gamma-emitting radionuclides in effluent releases. The radiochemistry laboratory will participate annually in a corporate interlaboratory comparison study or an equivalent study. The results of these studies will be provided to the NRC upon request.

11.2.3.

Abnormal Results The RBS laboratory values and the vendor laboratory "known values" should be compared by some evaluation criteria such as the EPA method, where the acceptable result lies between +/- three normalized standard deviations from the "known value"; or the NIST traceability method, where the difference between the RBS value and the "known value" should be less than the total propagated uncertainty of the difference. If deviations from such criteria exist, an evaluation will be performed to identify any recommended remedial actions to reduce anomalous errors. Complete documentation on the evaluation will be provided to the NRC upon request.

RSP-0008 REV - 13 PAGE 37 OF 104 RSP-0008 REV-13 PAGE37OF1O4

INFORMATION USE ATTACHMENT 1 PAGE 1 OF4 TABLE 4.1 - RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Pathway and/or Sample

1.

Airborne Particulates and I-131 Sample Point, Description, Distance, and Direction Samples from 4 locations:

Sampling and Collection Frequency Type and Frequency of Analysis API. Behind River Bend Station Activity Center, 0.9 km WNW.

AQS2. St. Francis Substation on US Hwy.

(Bus.) 61 in St Francisville; 5.8 km NW (Community Location).

AGC. Entergy Service Center compound in Zachary; 17 km SE (Control)

AN1. RBS site Hwy 965; 0.4 km south of Activity Center, 0.9 km W.

Continuous air sampler with filter collection every two weeks, or as required by dust loading, whichever is more frequent.

Charcoal cartridge: analysis every two weeks for 1-13 1. Particulate sampler: gross beta activity following filter changes every two weeks.

2.

Direct Radiation Measurements from 24 locations:

INDICATOR STATIONS TAI. River Bend Training Center; 1.7 km N.

Thermoluminescence dosimeters (TLDs);

deployment/retrieval quarterly.

mR exposure quarterly.

TB1. Utility pole near River Bend Station cooling tower yard area; 0.5 km NNE.

TCI. Stub pole at Jct. US Hwy. 61 and Old Highway 61; 1.7 km NE.

TDI. Stub pole along WF7, 150m S of Jct.

WF7 and US Hwy. 61; 1.6 km ENE.

TEl. Stub pole along WF7,1 km S of Jct. WF7 andUS Hwy. 61; 1.3 kmE.

TFl. Stub pole along WF7, 1.6 km S of Jct.

WF7 and US Hwy. 61; 1.3 km ESE.

TGI. Stub pole along WF7, 2km S of Jct. WF7 andUS Hwy. 61; 1.6 kn SE.

RSP-0008 REV -13 PAGE 38 OF 104

INFORMATION USE ATTACHMENT 1 PAGE 2 OF 4 TABLE 4.1 - RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Pathway Sample Point, Description, Sampling and Type and Frequency and/or Sample Distance, and Direction Collection Frequency of Analysis THI. Stub pole at power line crossing of WF7 (near Grants Bayou); 1.7 km SSE.

TJI. Stub pole near River Bend Station Gate

  1. 23 on Powell Station Road (LA Hwy. 965); 1.5 kn S.

TKI. Utility pole on Powell Station Road (LA Hwy. 965), 20 m S of River Bend Station River Access Road; 0.9 kn SSW.

TLI. First utility pole on Powell Station Road (LA Hwy. 965) S of former Illinois Central Gulf RR crossing; 1.0 km SW.

TMI. Third utility pole on Powell Station Road (LA Hwy. 965) N of former Illinois Central Gulf RR crossing; 0.9 kn WSW.

TNi. Utility pole along Powell Station Road (LA Hwy. 965), near garden and ANI air sampler location; 0.9 kn W.

TPI. Behind River Bend Station Activity Center at API air sampler location; 0.9 km WNW.

TQ1. Across from MAI on RBS North Access Road; 0.6 km NW.

TRI. River Bend Station North Access Road across from Main Plant entrance; 0.8 km NNW.

CONTROL/SPECIAL STATIONS TAC. Utility pole at Jct. of US Hwy. 61 and LA Hwy. 421, 7.9 km north of Bains; 15.8 km N.

(Control)

TQS1. Utility pole front of Pentecostal church (opposite West Feliciana Parish Hospital) near Jct. US Hwy. 61 and Commerce Street; 4 kma NW (Special)

RqP-0009 REV - 13 PAGE 39 OF 104 RSP-0008 REV -13 PAGE 39 OF 104

INFORMATION USE ATTACHMENT 1 PAGE 3 OF 4 TABLE 4.1 - RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Pathway and/or Sample Sample Point, Description, Distance, and Direction TQS2. St. Francis Substation on business US Hwy.61 in St Francisville; 5.8 km NW (Special).

TNS. Utility pole with electrical meter at west bank ferry landing (LA Hwy. 10); 6.0 km W.

(Special)

TEC. Stub pole at jcL of Hwy. 955 and Greenbrair Road, 4.8 km North of Jct. of Hwys 955 and 964; 16 Iam E. (Control)

TCS. Utility pole at gate to East Louisiana State Hospital in Jackson; 12.3 km NE. (Special)

TGS. Entergy Service Center compound in Zachary; 17 km SE (Special).

TRS. Stub pole at Jct. of US Hwy. 61 and WF2 near Bains. (West Feliciana High School); 9.2 km NNW. (Special)

SURFACE WATER (1)

SWU. Mississippi River about 4 km upstream from the plant liquid discharge outfall, near LA Hwy. 10 ferry crossing. (5km, W)

SWD. Mississippi River about 4 km downstream from plant liquid discharge outfall, near paper mill. (7.75 km, S)

GROUNDWATER Sampling and Collection Frequency Type and Frequency of Analysis 1

/"As

3.

Waterborne Quarterly grab.

Quarterly: gamma isotopic analysis; quarterly tritium analysis.

WU. Upland Terrace Aquifer well upgradient from plant, about 470 m NNE.

Semiannual grab Gamma isotopic and tritium analysis semiannually.

WD. Upland Terrace Aquifer well downgradient from plant, about 470 m SW.

RSP-0008 REV -13 PAGE 40 OF 104

INFORMATION USE ATTACHMENT 1 PAGE 4 OF 4 TABLE 4.1 - RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Pathway and/or Sample Sample Point, Description, Distance, and Direction Sampling and Collection Frequency Type and Frequency of Analysis SHORELINE SEDIMENT SEDD. Mississippi River downstream from plant liquid discharge outfall, near paper mill.

(7.75 km, S)

Annual grab Gamma isotopic analysis annually.

4. Ingestion()

FISH AND INVERTEBRATES FU. One sample of a commercially and/or recreationally important species from upstream area not influenced by plant discharge. (4 km, WSW)

Annually.

Gamma isotopic analysis on edible portions annually.

FD. One sample of a commercially and/or recreationally important species from downstream area influenced by plant discharge.

(7.75 km, S)

FOOD PRODUCTS GNI. One sample of leafy vegetation from onsite garden near site boundary in sector of highest calculated average ground level D/Q, (0.9 kn, W)

Quarterly during growing season.

Gamma isotopic and 1-131 analyses quarterly.

GQC. One sample of similar vegetation from LA State Penitentiary at Angola, 32 km NW (Control).

NOTES:

1. The upstream sample will be taken at a distance beyond signifi cant influence of the plant discharge. The downstream sample will be taken in an area beyond but near the mixing zone.
2. If milk-producing animals become available within a 8-km radius of the plant, sampling will be performed in accordance with Table 3.12.1-1, Section 4.a of the Technical Requirements ManuaL RSP-0008 REV-13 PAGE 41 OF 104

INFORMATION USE ATTACHMENT 2 PAGE 1 OF 1 ECL VALUES EFFLUENT CONCENTRATION LIMIT (gCi/ml)

NUCLIDE H-3 BE-7 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-56 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 ZN-69M SE-75 BR-82 BR-83 BR-84 RB-86 RB-88 RB-89 SR-85 SR-89 SR-90 SR-91 SR-92 Y-88 Y-90 Y-91M Y-91 Y-92 Y-93 ZR-95 ZR-97 NB-94 NB-95 NB-97 MO-90 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 AG-110M CD-109 CD-113M SN-113 SN-117M SB-122 SB-124 SB-125 AIR IE-07 3E-08 3E-09 7E-09 5E-10 3E-08 IE-09 2E-08 3E-09 5E-10 3E-10 9E-10 IE-09 5E-II IE-09 2E-08 3E-08 4E-10 2E-07 IE-08 8E-10 5E-09 9E-08 8E-08 IE-09 9E-08 2E-07 2E-09 2E-10 6E-12 5E-09 9E-09 3E-10 9E-10 2E-07 2E-10 IE-08 3E-09 4E-10 2E-09 2E-11 2E-09 IE-07 6E-09 2E-09 2E-07 5E-07 9E-10 2E-08 2E-1I IE-10 7E-11 5E-12 8E-10 2E-09 2E-09 3E-10 7E-10 WATER IE-03 6E-04 3E-05 5E-05 9E-06 5E-04 3E-05 7E-05 IE-04 IE-05 6E-06 6E-05 2E-05 3E-06 IE-04 IE-04 2E-04 5E-06 8E-04 6E-05 7E-06 4E-05 9E-04 4E-04 7E-06 4E-04 9E-04 4E-05 8E-06 5E-07 2E-05 4E-05 IE-05 7E-06 2E-03 8E-06 4E-05 2E-05 2E-05 9E-06 IE-05 3E-05 3E-04 3E-05 2E-05 IE-03 2E-03 3E-05 7E-05 3E-06 6E-06 6E-06 5E-07 3E-05 3E-05 IE-05 7E-06 3E-05 NUCLIDE SB-126 SB-127 TE-127M TE-127 TE-129M TE-129 TE-13 IM TE-131 TE-132 1-130 1-131 1-132 1-133 1-134 1-135 CS-134 CS-135 CS-136 CS-137 CS-138 BA-133 BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-139 CE-141-CE-143 CE-144 PR-143 PR-144 ND-147 EU-152 W-187 NP-239 AR-41 KR-83M KR-85M KR-85 KR-87 KR-88 KR-89 KR-90 XE-131M XE-133M XE-133 XE-135M XE-135 XE-137 XE-138 G-APLHA G-BETA OTHER RH-105 SC-46 AS-76 AIR 7E-10 IE-09 4E-10 2E-08 3E-10 9E-08 IE-09 2E-08 9E-10 3E-09 2E-10 2E-08 IE-09 6E-08 6E-09 2E-10 2E-09 9E-10 2E-10 8E-08 9E-10 4E-08 2E-09 IE-07 2E-07 2E-09 3E-08 9E-10 8E-10 2E-09 2E-11 9E-10 2E-07 IE-09 3E-II IE-08 3E-09 IE-08 5E-05 IE-07 7E-07 2E-08 9E-09 IE-09 IE-O9 2E-06 6E-07 5E-07 4E-08 7E-08 IE-09 2E-08 IE-15 IE-12 OE+OO 8E-09 3E-10 2E-09 WATER 7E-06 IE-05 9E-06 IE-04 7E-06 4E-04 8E-06 8E-05 9E-06 2E-05 IE-06 IE-04 7E-06 4E-04 3E-05 9E-07 IE-05 6E-06 IE-06 4E-04 2E-05 2E-04 8E-06 3E-04 7E-04 9E-06 IE-04 7E-05 3E-05 2E-05 3E-06 2E-05 6E-04 2E-05 IE-05 3E-05 2E-05 OE+OO OE+OO OE+OO OE+OO OE+oo OE+OO OE+OO OE+OO OE+OO OE+OO OE+OO OE+OO OE+OO OE+OO OE+OO 2E-09 IE-08 OE+OO 5E-05 1E-05 1E-05 i /0*

  • - Isotopes used for no gamma activity tanks based on TR Table 3.1 1.1.1-1 RSP-0008 REV - 13 PAGE 42 OF 104 RSP-OOO8 REV-13 PAGE42OF1O4

INFORMATION USE ATTACHMENT 3 PAGE 1 OF 2 TABLE B-1: LIQUID ENVIRONMENTAL DOSE TRANSFER FACTORS Ai, Table B-1 DOSE FACTOR TABLE: Ai, - Adult, liquid Units are mrem/hr per pICi/ml Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO.58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 ZN-69M BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91M Y-91 Y-92 Y-93 ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 AG-ib0M SB-124 SB-125 TE-125M TE-127M TE-127 O.OOE+00 2.81E-01 2.81E-01 2.81E-O1 4.61E+04 9.22E+03 9.22E+03 9.22E+03 6.02E+02 6.02E+02 6.02E+02 6.02E+02 4.85E+07 3.01E+06 1.87E+06 O.OOE+OO O.OOE+0O O.OOE+OO 4.31E+00 2.58E+00 O.OOE+00 2.39E+05 4.56E+04 O.OOE+O0 O.OOE+0O 6.02E+03 1.07E+03 O.OOE+00 5.68E+03 3.93E+03 9.16E+02 O.OOE+00 8.97E+03 2.1 1E+04 8.08E+03 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+OO O.OOE+O0 O.OOE+0O 1.74E+02 3.91E+02 O.OOE+OO O.OOE+0O 5.O1E+02 1.I1E+03 O.OOE+OO 3.86E+04 2.68E+03 1.29E+03 O.OOE+00 1.57E+02 2.04E+01 9.29E+00 O.OOE+00 O.OOE+0O 2.90E+01 1.36E+01 O.OOE+00 5.09E+04 1.62E+05 7.31E+04 O.OOE+00 1.08E+02 2.07E+02 1.44E+O1 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4.81E+01 O.OOE+OO O.OOE+00 O.OOE+00 6.23E+01 O.OOE+0O O.OOE+00 O.OOE+00 2.56E+00 O.OOE+00 O.OOE+00 1.13E+05 5.28E+04 O.OOE+O0 O.OOE+OO 3.25E+02 1.72E+02 O.OOE+0O O.OOE+00 2.15E+02 1.51E+02 O.OOE+OO 3.97E+04 O.OOE+00 1.14E+03 O.OOE+00 9.78E+05 O.OOE+00 2.40E+05 O.OOE+0O 7.32E+02 O.OOE+OO 2.96E+O1 O.OOE+00 2.77E+02 O.OOE+00 1.20E+01 O.OOE+00 6.07E+O0 O.OOE+00 1.63E-01 O.OOE+OO 5.74E-02 O.OOE+00 2.22E-03 O.OOE+00 8.90E+I01 O.OOE+00 2.38E+0O O.OOE+00 5.33E-01 O.OOE+00 1.56E-02 O.OOE+00 1.69E+0O O.OOE+OO 4.67E-02 O.OOE+00 3.57E-01 1.14E-01 7.75E-02 O.OOE+00 1.97E-02 3.98E-03 1.82E-03 O.OOE+0O 4.48E+02 2.49E+02 1.34E+02 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 1.28E+02 2.44E+01 O.OOE+00 9.59E-03 2.71E-02 3.45E-01 O.OOE+00 9.86E-03 1.42E-02 1.39E-01 O.OOE+00 3.61E+O1 O.OOE+0O 1.56E+O1 O.OOE+OO 3.01E+O0 O.OOE+00 1.19E+00 O.OOE+00 5.37E+02 O.OOE+00 6.80E+01 0.OOE+00 5.38E-04 4.98E-04 2.95E-04 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 1.19E+04 4.31E+03 1.59E+03 3.58E+03 3.01E+04 1.08E+04 3.66E+03 7.69E+03 4.89E+02 1.75E+02 1.06E+02 3.62E+02 2.81E-01 2.81E-01 9.22E+03 9.22E+03 6.02E+02 6.02E+02 O.OOE+0O O.OOE+00 9.50E-01 5.72E+OO 7.12E+04 O.OOE+00 7.64E+03 O.OOE+00 O.OOE+0O 2.19E+03 O.OOE+00 5.89E+03 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+0O O.OOE+OO O.OOE+0O 7.31E+O1 O.OOE+00 1.08E+05 O.OOE+00 1.34E+02 O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+0O O.OOE+OO O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+0O O.OOE+0O 1.80E-O1 O.OOE+0O 6.01E-03 O.OOE+00 2.46E+02 O.OOE+00 O.OOE+0O O.OOE+OO 2.90E+02 O.OOE+0O 4.12E-01 1.33E-02 2.56E-01 7.26E-03 1.38E+02 O.OOE+00 3.89E+01 O.OOE+O0 1.04E+03 O.OOE+00 9.78E-04 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+0O 4.84E+04 O.OOE+00 1.22E+05 O.OOE+00 1.99E+03 O.OOE+OO 2.81lE-01 9.22E+03 6.02E+02 5.45E+06 1.08E+03 7.33E+05 1.92E+05 2.25E+03 7.03E+04 O.OOE+00 3.54E+03 9.41E+03 5.58E+02

5. 17E+02 2.47E+03 1.02E+05 3.11E+01 O.OOE+00 O.OOE+O0 6.92E+01 4.89E-04 0.OOE+00 2.23E+04 4,49E-09 1.25E-1 1 6.38E+03 2.83E+04 3.48E+03 5.50E+03 6.44E+04 1.68E-01 4.90E+04 9.34E+03 5.36E+04 3.63E+02 1.23E+03 1.5 1E+06 0.OOE+00 2.97E+02 1.60E+01 4.27E-14 4.22E+03 1.84E+03 3.48E+04 2.03E-01 0.OOE+00 0.OOE+00 4.75E+04 1.O1E+05 3.86E+04 0.OOE+00 0.OOE+0o 0.OOE+00 0.OOE+0o 0.OOE+00 0.OOE+0o 0.OOE+oo O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+oo O.OOE+oo 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+oo O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+oo 0.OOE+oo 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+oo 0.OOE+oo 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+O0 0.OOE+oo 0.OOE+00 0.OOE+00 0.OOE+oo 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+O0 RSP-0008 REV - 13 PAGE 43 OF 104 RSP-0008 REV-13 PAGE43OFiO4

INFORMATION USE ATTACHMENT 3 PAGE 2 OF 2 TABLE B-1: LIQUID ENVIRONMENTAL DOSE TRANSFER FACTORS Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-129M 5.1 1E+04 1.91E+04 8.09E+03 1.75E+04 2.13E+05 O.OOE+00 2.57E+05 O.OOE+00 TE-129 1.39E+02 5.24E+01 3.40E+01 1.07E+02 5.86E+02 O.OOE+00 1.05E+02 0.OOE+0O TE131M 7.69E+03 3.76E+03 3.13E+03 5.95E+03 3.81E+04 O.OOE+00 3.73E+05 O.OOE+00 TE-131 8.75E+01 3.66E+O1 2.76E+01 7.20E+01 3.83E+02 O.OOE+00 1.24E+01 O.OOE+00 TE-132 1.12E+04 7.24E+03 6.80E+03 8.00E+03 6.97E+04 O.OOE+00 3.43E+05 O.OOE+O0 I-130 2.94E+01 8.66E+01 3.42E+01 7.34E+03 1.35E+02 O.OOE+00 7.46E+01 O.OOE+00 I-131 1.62E+02 2.31E+02 1.32E+02 7.57E+04 3.96E+02 O.OOE+00 6.10E+01 0.OOE+00 I-132 7.88E+00 2.11E+01 7.38E+00 7.38E+02 3.36E+01 O.OOE+00 3.96E+00 O.OOE+O0 I-133 5.51E+01 9.59E+01 2.92E+01 1.41E+04 1.67E+02 O.OOE+00 8.62E+01 O.OOE+00 I-134 4.12E+00 1.12E+01 4.OOE+00 1.94E+02 1.78E+01 O.OOE+00 9.75E-03 O.OOE+OO I-135 1.72E+01 4.50E+01 1.66E+01 2.97E+03 7.22E+01 O.OOE+00 5.09E+01 O.OOE+OO CS-134 3.34E+05 7.94E+05 6.49E+05 O.OOE+00 2.57E+05 8.53E+04 1.39E+04 O.OOE+OO CS-136 3.49E+04 1.38E+05 9.93E+04 O.OOE+O0 7.68E+04 1.05E+04 1.57E+04 O.OOE+00 CS-137 4.28E+05 5.85E+05 3.83E+05 O.OOE+00 1.99E+05 6.60E+04 1.13E+04 O.OOE+00 CS-138 2.96E+02 5.85E+02 2.90E+02 O.OOE+00 4.30E+02 4.25E+01 2.50E-03 O.OOE+00 BA-139 1.20E+01 8.55E-03 3.52E-01 O.OOE+00 8.OOE-03 4.85E-03 2.13E+01 O.OOE+00 BA-140 2.51E+03 3.16E+00 1.65E+02 O.OOE+00 1.07E+00 1.81E+00 5.17E+03 O.OOE+00 BA-141 5.83E+00 4.41E-03 1.97E-01 O.OOE+00 4.10E-03 2.50E-03 2.75E-09 O.OOE+O0 BA-142 2.64E+00 2.71E-03 1.66E-01 O.OOE+00 2.29E-03 1.54E-03 3.71E-18 O.OOE+O0 LA-140 1.58E+00 7.95E-01 2.10E-01 O.OOE+0O O.OOE+O0 O.OOE+00 5.84E+04 O.OOE+00 LA-142 8.08E-02 3.67E-02 9.15E-03 0.OOE+00 O.OOE+O0 O.OOE+00 2.68E+02 O.OOE+00 CE-141 5.37E+00 3.63E+00 4.12E-01 0.OOE+00 1.69E+0O O.OOE+00 1.39E+04 O.OOE+00 CE-143 9.46E-01 7.OOE+02 7.74E-02 O.OOE+00 3.08E-01 0.OOE+00 2.61E+04 O.OOE+00 CE-144 2.80E+02 1.17E+02 1.50E+O1 O.OOE+00 6.94E+01 O.OOE+0O 9.46E+04 O.OOE+O0 PR-143 5.80E+00 2.33E+00 2.88E-01 O.OOE+00 1.34E+00 O.OOE+00 2.54E+04 O.OOE+00 PR-144 1.90E-02 7.89E-03 9.65E-04 O.OOE+00 4.45E-03 O.OOE+00 2.73E-09 O.OOE+00 ND-147 3.97E+00 4.59E+00 2.74E-01 O.OOE+00 2.68E+00 O.OOE+00 2.20E+04 O.OOE+00 W-187 2.97E+02 2.48E+02 8.68E+01 O.OOE+O0 O.OOE+00 O.OOE+00 8.13E+04 O.OOE+00 NP-239 3.00E-01 2.95E-02 1.63E-02 O.OOE+OO 9.21E-02 O.OOE+00 6.06E+03 O.OOE+00 RSP-0008 REV - 13 PAGF 44 OF 104 RSP-0008 REV-13 PAGE44OF1O4

INFORMATION USE ATTACHMENT 4 PAGE C OF E TABLE C-1: NOBLE GAS DOSE TRANSFER FACTORS TABLE C-1 FACTOR FOR EXPOSURE TO A SEMI-INFINITE CLOUD DOSE TO PEOPLE +

DOSE OF AIR Nuclide Gamma-Body Beta-Skin Skin Gamma Beta K (i)

L (i)

L(i)+ (1.1)M(i)

M (i)

N (i)

AR-41 KR-83M KR-85 KR-85M KR-87 KR-88 KR-89 KR-90 XE-131M XE-133 XE-133M XE-135 XE-135M XE-137 XE-138 8.840E+03 7.560E-02 1.610E+01 1.170E+03 5.920E+03 1.470E+04 1.660E+04 1.560E+04 9.150E+01 2.940E+02 2.510E+02 1.810E+03 3.120E+03 1.420E+03 8.830E+03 2.690E+03 O.OOOE+00 1.340E+03 1.460E+03 9.730E+03 2.370E+03 1.010E+04 7.290E+03 4.760E+02 3.060E+02 9.940E+02 1.860E+03 7.1 1OE+02 1.220E+04 4.130E+03 1.29E+04 2.12E+01 1.36E+03 2.81E+03 1.65E+04 1.91E+04 2.91E+04 2.52E+04 6.48E+02 6.94E+02 1.35E+03 3.97E+03 4.4 1E+03 1.39E+04 1.43E+04 9.300E+03 1.930E+01 1.720E+01 1.230E+03 6.170E+03 1.520E+04 1.730E+04 1.630E+04 1.560E+02 3.530E+02 3.270E+02 1.920E+03 3.360E+03 1.510E+03 9.210E+03 3.280E+03 2.880E+02 1.950E+03 1.970E+03 1.030E+04 2.930E+03 1.060E+04 7.830E+03 1.11OE+03 1.050E+03 1.480E+03 2.460E+03 7.390E+02 1.270E+04 4.750E+03

+ -- mremlyr per.Ci/cu.rn.

  1. -- mrad/yr per g.Ci/cu.m.

RSP-0008 REV-13 PAGE 45 OF 104

INFORMATION USE ATTACHMENT 5 PAGE I OF 1 (RESERVED)

RSP-0008 REV-13 PAGE 46 OF 104

INFORMATION USE ATTACHMENT 6 PAGE 1 OF4 X/Q AND D/Q VALUES FOR RESTRICTED AREA BOUNDARY Long Term Diffusion Estimates E. 1 Objective Annual average CHI/Q and D/Q estimates for continuous and intermittent releases were calculated for each of the sixteen 22.5-degree sectors at receptor locations used to determine the maximum individual and population dose receptors.

The methodology described in Regulatory Guide 1. 111, Rev. 1 provided guidance for the aforementioned analysis. The resultant CHI/Q and D/Q values for the maximum individual dose receptors are displayed in Attachment 9.

E.2 Calculation Techniques Nomenclature 2.032 =

t =

(23/.)

15(2./.16).

3.14159..

EXP=

2.71828 ET =

ENTRAINMENT COEFFICIENT nT=

TERRAIN RECIRCULATION FACTOR X =

DOWNWIND RECEPTOR DISTANCE az =

VERTICAL DISPERSION (PLUME SPREAD) COEFFICIENT ulo 30-FT AVERAGE WIND SPEED CORRESPONDING TO A GIVEN HOUR OF ONSITE METEOROLOGICAL DATA U50=

150-FT AVERAGE WIND SPEED CORRESPONDING T A GIVEN HOUR OF ON-SITE METEOROLOGICAL DATA (CHI/Q) -

AVERAGE CONCENTRATION NORMAL-IZED BY SOURCE STRENGTH (CHI/QD) =

DEPLETED CHI/Q FM =

MOMENTUM FLUX HB=

MAXIMUM ADJACENT BUILDING HEIGHT HR =

RELEASE HEIGHT HE =

EFFECTIVE RELEASE HEIGHT HPR =

NONBUOYANT PLUME RISE HT =

TOPOGRAPHIC HEIGHT OF RECEPTOR ABOVE PLANT GRADE D =

STACK OR VENT DIAMETER UE=

EFFLUX VELOCITY N =

TOTAL NUMBER OF VALID HOURS OF ONSITE WIND DATA IN ALL SECTORS FOR APPLICABLE AVERAGING PERIOD

/Q RELATIVE DEPOSITION RATE NORMALIZED BY SOURCE STRENGTH D/Q

RELATIVE DEPOSITION PER UNIT AREA NORMALIZED BY SOURCE STRENGTH G =

GROUND RELEASE (SUBSCRIPT)

(DIMENSIONLESS)

(DIMENSIONLESS)

(DIMENSIONLESS)

(DIMENSIONLESS)

(DIMENSIONLESS)

(M)

(M SEC -1)

(SEC M-3)

(SEC M-3)

(M4 SEC3)

(M)

(M)

~M (M SEC-)

(DIMENSIONLESS)

(Ml)

(DIMENSIONLESS)

RSP-0008 REV-13 PAGE 47 OF 104

INFORMATION USE ATTACHMENT 6 PAGE 2 OF 4 X/Q AND D/Q VALUES FOR RESTRICTED AREA BOUNDARY I =

INDEX FOR ATMOSPHERIC STABILITY GROUP (CLASSES A (DIMENSIONLESS)

THROUGH G)

J =

INDEX FOR NUMBER OF HOURS (DIMENSIONLESS)

K =

INDEX FOR A PARTICULAR RECEPTOR DISTANCE (DIMENSIONLESS)

£ =

INDEX FOR A PARTICULAR 22.5-DEGREE SECTOR (DIMENSIONLESS)

N =

NUMBER OF HOURS ONSITE WIND DATA IN A (DIMENSIONLESS)

PARTICULAR 22.5-DEGREE SECTOR S =

STABILITY PARAMETER (SEC 2 E.3 CHI/O Modeling Technique Annual average values of relative concentration were calculated for continuous gaseous releases of activity from the containment building vent and the radwaste building vent according to the straight-line airflow (Gaussian) model described in Regulatory Guide 1. 111, Rev. 1. An adjustment was made to the model to characterize the regional airflow pattern. The equation of this model is as follows:

(CHI) 2.032

(

[

ET

+ (1 E )ePI/2(E.3-1 Q

i

.N j-lx )

U3(a2 _ Chb2,_112 U50 Since the River Bend Station site is located in relatively open terrain, the terrain recirculation factor (rh) (presented in Figure 2 of Regulatory Guide 1.111) was applied.

The entrainment coefficient (ET) is a function of the ratio of efflux velocity (ue) to elevated wind speed (u 150) for the conditionally elevated release points.

For vent releases occurring below the level of a nearby structure, 100 percent downwash (total entrainment) is conservatively assumed (ET = 1). For vent releases occurring between 1 and 2 times the height of a nearby structure, a conditionally elevated release is assumed, and the entrainment coefficient is defined as follows:

ET = 0.0 when ue/ui50 2 5.0 (totally elevated)

ET = 0.30-0.06 when 1.5 < ue/u50 < 5.0 (partially entrained)

ET = 2.58-1.58 when 1.0

  • u,/u150 _ 1.5 (partially entrained)

ET = 1.0 when ut/u,50 S 1.0 (totally entrained)

Within 5 km in each downwind sector, Equation E.3-1 was evaluated by sector at the property and restricted area boundaries and nearest resident, vegetable garden, milk cow, and meat animal. There were no goats whose milk is consumed in the area of interest. This evaluation was performed for each continuously emitting release point and the intermittent release from the mechanical vacuum pump with onsite data collected during the period of March 17, 1977 through March 16, 1979.

RSP-0008 REV-13 PAGE 48 OF 104

INFORMATION USE ATTACHMENT 6 PAGE 3 OF 4 X/Q AND D/Q VALUES FOR RESTRICTED AREA BOUNDARY The effective release height was computed from the following equation:

he = (h1 - ht)k + hp, E.3-2 Where the downwash correction factor (as defined by Equation (5) in Regulatory Guide 1.11 1, Rev.

1) is included in the equation for hpr (see Equation E.3-4).

Values of topographic heights were conservatively assessed as the maximum height within a particular annulus-sector (annsect). An annsect is an area bounded by a 22.5-degree sector and any two radial distances from the release point.

For A-D stability conditions, plume rise for nonbuoyant sources was calculated by the following algorithm:

when:

ue/uI50 > 1.5 hpr = 1. 44(u. / uso)"' (x /d) 13d when:

ue/IuS <

1,5 hpr = 1.44(ue /u 150) 213(x / d)" 3 (d -3) [1.5- (ue / u150)d]

and, hp,<3(ue / U150)

E.3-3 E.3-4 E.3-5 The result from Equation E.3-3 or E.3-4 (whichever condition exists) is then compared to Equation E.3-5 and the smaller value of hpr is used.

For E-G stability conditions, Equations E.3-3, E.3-4, and E.3-5 are compared with:

hp, = 4Fm/s)1/4 and hpr = 1.5(Fm / U15 0) 1 3 S_1 6 where:

(u.) 2d2 Fm =

4 and the smallest value was chosen.

RSP-0008 REV-13 PAGE 49 OF 104

INFORMATION USE ATTACHMENT 6 PAGE 4 OF 4 X/Q AND D/Q VALUES FOR RESTRICTED AREA BOUNDARY In the ground level portion of Equation E.3-1, the vertical dispersion term:

(ik

+0.5hb/,r) was constrained to be less than or equal to 1.732 caZik E.4 (CHI/O) and D/O Modeling Techniques Annual average depleted relative concentration values were conservatively assumed to be equal to annual average relative concentration values (CHI/Q = (CHI/Q)D). Therefore, no credit was taken for attendant plume depletion of radioiodines and particulates.

Annual average relative deposition values were calculated using Regulatory Guide 1.1 11, Rev. 1 with the following equation:

CQ~n.

(E)T(21 6N)1I.1[n{(J(kET + 3n I I - (ET)n.(

}]}

E.4-1 For the conditionally elevated release points, Figures 6 through 9 of Regulatory Guide 1.1 11, Rev. 1 were used to calculate the (6/Q)G and (8/Q)i values, while for the ground level release points, Figure 6 (Attachment 39) was utilized to calculate the (S/Q)G value.

E.5 Methodology Employed for Intermittent Release The methodology employed in the calculation of intermittent release CHIIQs and D/Qs was as follows:

1. Two-hour sector-averaged CHI/Q values were calculated without terrain recirculation factors.
2. The 15 percent, 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> value was plotted at 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> on log-log coordinates, while the annual average value was plotted at 8,760 hr. A straight line connecting the two points was drawn.
3. Log-log interpolation based on total ground intermittent release hours versus annual hours yielded a CHI/Q multiplier.
4. The multiplier was applied to annual average CHI/Q and D/Q values to obtain intermittent CHI/Q and D/Q values.

For River Bend Station, a 320 hr/yr intermittent release through the containment building vent from the mechanical vacuum pump was evaluated.

RSP-0008 REV -13 PAGE 50 OF 104

INFORMATION USE ATTACHMENT 7 PAGE I OF I TABLE E-1: ANNUAL AVERAGE CHI/Q VALUES FOR RESTRICTED AREA BOUNDARY TABLE E-1 ANNUAL AVERAGE CHI/Q VALUES x 10-7 (sec/m3)

FOR RESTRICTED AREA BOUNDARY Sector Mixed Mode Releases Ground Level Releases (Continuous)

Exhaust (Continuous)

S 11.4 105 SSW 19.7 186 SW 16.4 215 WSW 19.5 326 W

23.6 654 WNW 33.1 421 NW 15.7 262 NNW 14.8 138 N

18.8 180 NNE 24.9 211 NE 16.6 150 ENE 12.2 146 E

9.07 168 ESE 10.4 154 SE 8.19 93.1 SSE 7.69 45.6 RSP-0008 REV-13 PAGE 51 OF 104

INFORMATION USE ATTACHMENT 8 PAGE l OF I TABLE E-2: ANNUAL AVERAGE D/Q VALUES FOR RESTRICTED AREA BOUNDARY TABLE E-2 ANNUAL AVERAGE D/Q VALUES x 10-9 (m-2)

FOR RESTRICTED AREA BOUNDARY Sector S

SSW SW WSW W

WNW NW NNW N

NNE NE ENE E

ESE SE SSE Mixed Mode Releases (Continuous) 7.61 11.3 10.4 9.79 13.8 18.0 8.68 10.5 11.8 11.2 8.26 9.73 7.75 7.76 6.60 5.34 Ground Level Releases (Continuous) 21.4 39.6 36.1 38.5 68.8 50.3 40.8 24.7 28.6 27.1 22.3 22.7 23.0 24.6 17.2 11.8 RSP-0008 REV-13 PAGE 52 OF 104

INFORMATION USE ATTACHMENT 9 PAGE I OF I TABLE F-1: ATMOSPHERIC DISPERSION AND DEPOSITION RATES FOR THE MAXIMUM INDIVIDUAL DOSE CALCULATIONS TABLE F-1 ATMOSPHERIC DISPERSION AND DEPOSITION RATES FOR THE MAXIMUM INDIVIDUAL DOSE CALCULATIONS Analysis Location Ground level Mixed Mode (meters)

Releases Releases Gamma air dose (3) and Beta 994 m WNW (Containment)

CHIIQ - 421.0 CHI'Q - 33.1 Air Dose Maximum Receptor (4) 994 m WNW CHI/Q - 421.0 CHIIQ - 33.1 Resident D/Q -

50.3 D/Q - 18.1 Garden Meat animal Immersion Milk animal (5) 7,000 m WNW CHI/Q -

3.58 CHI/Q -.870 D/Q -

0.38 D/Q -. 223 Other on-site Receptors (6) 115 m ENE CHI/Q -

5977.0 CHI/Q - 407.5 D/Q -

529.7 D/Q - 46.9 275mN CHI/Q - 1644.0 CHI/Q - 169.1 D/Q - 345.6 D/Q - 68.4 500 WNW CHI/Q - 916.7 CHI/Q - 105.4 D/Q -

148.1 D/Q - 45.6 2500 SW CHIIQ -

34.45 CHIIQ - 4.65 D/Q -

3.35 D/Q - 1.40

  • Reference 2.8 and 2.6 Notes:

(1) All CHIIQ = I0- sec/m3 (2) All D/Q = 109 m^2 (3) Maximum offsite location (property boundary) with highest CHI/Q (unoccupied).

(4) Maximum hypothetical occupied offsite location with highest CHI/Q and D/Q.

(5) No milk animal within 5 miles radius, hypothetical location in worst sector.

(6) Other on-site receptors.

(7) Revisions to CHI/Q and D/Q can be performed using Reference 2.14 RSP-0008 REV-13 PAGE 53 OF 104

INFORMATION USE ATTACHMENT 10 PAGET OF I TABLE G-1: DOSE FACTOR CALCULATION PARAMETERS CODE DESCRIPTION VALUE UNITS csf Harvest stored feed to cow 7.776E+06 seconds (cfs) dw Drinking Water Dilution Factor 2.480E+04 none (dw) esf Stored feed exp. to deposition 5.184E+06 seconds (esf) fg Fraction Stored Veg. Intake 7.600E-01 none (fg) fi Fraction Vegetation Irrigated 1.OOOE-01 none (fi) fl Fraction Leafy Veg. Intake I.OOOE+OO none (fi) fpc Fraction Year Cow On Pasture 1.OOOE+OO none (fpc) fpg Fraction Year Goat On Pasture 1.OOOE+00 none (fpg) fsc Fraction Cow Feed-Pasture Grass 1.OOOE+00 none (fsc) fsg Fraction Goat Feed-Pasture Grass 1.OOOE+OO none (fsg) gsf Harvest stored feed to goat 7.776E+06 seconds (gsf) h Absolute Humidity 1.290E+01 gm/m3 (h) kc Water to sediment xfer coeff.

7.220E-02 L/kg hr (kc) ksf Liq conv fact pCi*ml*yr/liCi* I *hr

1. 142E+05 (ksf)

Iv Water content of Leafy Veg 9.200E-0 1 L/kg (lv) lw Surface Weather Decay Constant 5.730E-07 1/seconds (1w)

Iwr Iodine Surface Wx Decay Constant 5.730E-07 I/seconds (Iwr) mtv Mass density of sediment 4.OOOE+01 kg/m2 (mtv) p Effective surface density, soil 2.400E+02 kg/m2 (p )

p14 Fractional equilibrium ratio 1.OOOE+O0 none (pl4) gfc Cow's Feed Consumption Rate 5.OOOE+01 kg/day (qfc) gfg Goat's Feed Consumption Rate 6.OOOE+0O kg/day (qfg) ri Fraction Deposited Liquid 2.500E-O1 none (ri )

rp Fraction Deposited Particulate 2.000E-01 none (rp) rr Fraction Deposited Radioiodine 1.OOOE+0O none (rr) sf Shielding Factor 1.OOOE+0O none **

(sO

  • tb Long term sediment exposure O.OOOE+O0 seconds (tb) tbl Long term sediment exp. liquid 4.716E+08 seconds (tbl) tei Veg. Exposure in Growing Season 5.184E+06 seconds (tei) tem Seasonal forage exposure (milk) 2.592E+06 seconds (tem) tev Seasonal crop exposure (veg) 8.OOOE+06 seconds (tev) tfh Fresh Fish Transit Time O.OOOE+0O seconds (tfh) tgm Time, goat milking to receptor 1.728E+05 seconds (tgm) thi Transit Time-Harvest Irrig. Veg 8.640E+04 seconds (thi) thv Transit Time-Harvest-Stored Veg 5.184E+06 seconds (thv) ti Fresh Non-Fish Transit Time O.OOOE+00 seconds (ti).

tl Transit Time-Harvest-Leafy Veg 8.640E+04 seconds (tl) tmc Time, cow miling to receptor 1.728E+05 seconds (tmc) ts Time, slaughter to consumer 1.728E+06 seconds (ts) tw Drinking Water Transit Time O.OOOE+OO seconds (tw) yiv Irrigated Veg. Areal Density 2.OOOE+O0 kg/m2 (yiv) yp Pasture Grass Areal Density 7.OOOE-O1 kg/m2 (yp) ys Stored Feed Areal Density 2.OOOE+0O kg/m2 (ys) ysv Stored Vegetable Areal Density 2.OOOE+O0 kg/m2 (ysv) yv Vegetation Areal Density 2.000E+OO kg/m2 (yv)

  • tb-needs to be 4.716E+08 when calculating Ground Plane Dose Factors

INFORMATION USE ATTACHMENT 11 PAGE 1 OF 2 TABLE G-2: STABLE ELEMENT TRANSFER FACTORS Nuclide H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 ZN-69M BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91M Y-91 Y-92 Y-93 ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 AG-l1lM Milk Cow 1.OOOE-02 1.200E-02 4.OOOE-02 2.500E-02 2.200E-03 2.500E-04 2.500E-04 1.200E-03 1.200E-03 l.OOOE-03 l.OOOE-03 1.OOOE-03 6.700E-03 6.700E-03 1.400E-02 3.900E-02 3.900E-02 3.900E-02 5.OOOE-02 5.OOOE-02 5.OOOE-02 5.OOOE-02 3.OOOE-02 3.OOOE-02 3.OOOE-02 8.OOOE-04 8.OOOE-04 8.OOOE-04 8.000E-04 1.OOOE-05 1.OOOE-05 1.OOOE-05 1.OOOE-05 1.OOOE-05 5.OOOE-06 5.OOOE-06 2.500E-03 2.500E-03 7.500E-03 2.500E-02 2.500E-02 l.OOOE-06 1.OOOE-06 I.OOOE-06 5.OOOE-02 Milk Goat 1.700E-01 1.OOOE-01 4.OOOE-02 2.500E-01 2.200E-03 2.500E-04 2.500E-04 1.300E-04 1.300E-04 1.OOOE-03 1.OOOE-03 1.OOOE-03 6.700E-03 6.700E-03 1.300E-02 3.900E-02 3.900E-02 3.900E-02 5.OOOE-02 5.OOOE-02 5.OOOE-02 5.OOOE-02 3.OOOE-02 3.OOOE-02 3.OOOE-02 1.400E-02 1.400E-02 1.400E-02 1.400E-02 1.OOOE-05 1.000E-05 1.OOOE-05 I.OOOE-05 1.OOOE-05 5.OOOE-06 5.OOOE-06 2.500E-03 2.500E-03 7.500E-03 2.500E-02 2.500E-02 1.OOOE-06 l.OOOE-06 I.OOOE-06 5.OOOE-02 Meat 1.200E-02 3.1OOE-02 3.OOOE-02 4.600E-02 2.400E-03 8.OOOE-04 8.OOOE-04 4.OOOE-02 4.OOOE-02 1.300E-02 1.300E-02 1.300E-02 5.300E-02 5.300E-02 8.OOOE-03 3.OOOE-02 3.OOOE-02 3.OOOE-02 2.600E-02 2.600E-02 2.600E-02 2.600E-02

3. 100E-02 3.100E-02
3. 100E-02 6.OOOE-04 6.OOOE-04 6.OOOE-04 6.OOOE-04 4.600E-03 4.600E-03 4.600E-03 4.600E-03 4.600E-03 3.400E-02 3.400E-02 2.800E-01 2.800E-01 8.OOOE-03 4.OOOE-0I 4.OOOE-Ol 4.OOOE-01 4.OOOE-01 4.OOOE-01 1.700E-02 Veg./Soil 4.800E+O0 5.500E+00 5.200E-02
1. lOOE+00 2.500E-04 2.900E-02 2.900E-02 6.600E-04 6.600E-04 9.400E-03 9.400E-03 9.400E-03 1.900E-02 1.900E-02 1.200E-01 4.OOOE-01 4.OOOE-01 4.OOOE-01 7.600E-01 7.600E-01 7.600E-0l 7.600E-01 1.300E-01 1.300E-O1 1.300E-01 1.700E-02 1.700E-02 1.700E-02 1.700E-02 2.600E-03 2.600E-03 2.600E-03 2.600E-03 2.600E-03 1.700E-04 1.700E-04 9.400E-03 9.400E-03 1.200E-01 2.500E-01 2.500E-O1 5.OOOE-02 5.OOOE-02 5.OOOE-02 1.500E-01 RSP-0008 REV-13 PAGE 55 OF 104

INFORMATION USE ATTACHMENT 11 PAGE 2 OF 2 TABLE G-2: STABLE ELEMENT TRANSFER FACTORS Nuclide Milk Cow Milk Goat Meat Veg./Soil SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 1-130 1-131 I-132 1-133 1-134 1-135 CS-134 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 W-187 NP-239 1.500E-03 I.500E-03 1.OOOE-03 1.OOOE-03 I.OOOE-03 1.OOOE-03 1.OOOE-03 1.OOOE-03 I.OOOE-03 1.OOOE-03 6.OOOE-03 6.OOOE-03 6.OOOE-03 6.OOOE-03 6.OOOE-03 6.OOOE-03 1.200E-02 1.200E-02 1.200E-02 1.200E-02 4.OOOE-04 4.OOOE-04 4.OOOE-04 5.OOOE-06 5.OOOE-06 1.OOOE-04 1.OOOE-04 I.OOOE-04 5.OOOE-06 5.OOOE-06 5.OOOE-06 5.OOOE-04 5.OOOE-06 1.500E-03 1.500E-03 1.OOOE-03 1.OOOE-03 1.OOOE-03 1.OOOE-03 1.000E-03 1.000E-03 1.OOOE-03 1.OOOE-03 6.OOOE-02 6.OOOE-02 6.OOOE-02 6.OOOE-02 6.OOOE-02 6.OOOE-02 3.OOOE-0I 3.OOOE-01 3.OOOE-01 3.OOOE-01 4.OOOE-04 4.OOOE-04 4.OOOE-04 5.OOOE-06 5.OOOE-06 1.OOOE-04 1.OOOE-04 1.OOOE-04 5.OOOE-06 5.OOOE-06 5.OOOE-06 5.OOOE-04 5.OOOE-06 Units: Milk - days/liter Meat - days/kg Soil - unitless O.OOOE+00 O.OOOE+00 7.700E-02 7.700E-02 7.700E-02 7.700E-02 7.700E-02 7.700E-02 7.700E-02 7.700E-02 2.900E-03 2.900E-03 2.900E-03 2.900E-03 2.900E-03 2.900E-03 4.OOOE-03 4.OOOE-03 4.OOOE-03 4.OOOE-03 3.200E-03 3.200E-03 3.200E-03 2.OOOE-04 2.OOOE-04 1.200E-03 1.200E-03 1.200E-03 4.700E-03 4.700E-03 3.300E-03 1.300E-03 2.OOOE-04 O.OOOE+00 0.OOOE+00 1.300E+O0 1.300E+00 1.300E+00 1.300E+00 1.300E+00 1.300E+00 1.300E+O0 1.300E+O0 2.OOOE-02 2.OOOE-02 2.OOOE-02 2.OOOE-02 2.OOOE-02 2.OOOE-02 1.OOOE-02 I.OOOE-02 1.OOOE-02 1.OOOE-02 5.OOOE-03 5.OOOE-03 5.OOOE-03 2.500E-03 2.500E-03 2.500E-03 2.500E-03 2.500E-03 2.500E-03 2.500E-03 2.400E-03 1.800E-02 2.500E-03 RSP-0008 REV-13 PAGE 56 OF 104

INFORMATION USE ATTACHMENT 12 PAGE 1 0F2 TABLE G-3: BIOACCUMULATION FACTORS TABLE G-3 BIOACCUMULATION FACTORS Freshwater Freshwater Saltwater Saltwater Nuclide Fish Non-Fish Fish Non-Fish H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 ZN-69M BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91M Y-91 Y-92 Y-93 ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-I05 RU-106 AG-i lOM 9.OOOE-Ol 4.600E+03 1.OOOE+02 1.000E+05 2.OOOE+02 4.OOOE+02 4.OOOE+02 1.000E+03 1.000E+02 5.OOOE+Ol 5.OOOE+O1 5.OOOE+O I 1.OOOE+02 1.OOOE+02 5.OOOE+O1 2.OOOE+03 2.OOOE+03 2.OOOE+03 4.200E+02 4.200E+02 4.200E+02 4.200E+02 2.000E+03 2.OOOE+03 2.OOOE+03 3.OOOE+O1 3.OOOE+O1 3.OOOE+O1 3.OOOE+OI 2.500E+O1 2.500E+Ol 2.500E+O1 2.500E+O1 2.500E+O1 3.300E+OO 3.300E+OO 3.OOOE+04 3.OOOE+04 1.OOOE+O1 1.500E+O1 1.500E+O1 1.OOOE+O1 l.OOOE+O1 1.OOOE+O1 O.OOOE+OO 9.OOOE-O1 9.1 OOE+03 2.OOOE+02 2.OOOE+04 2.OOOE+03 9.OOOE+04 9.OOOE+04 3.200E+03 3.200E+03 2.OOOE+02 2.OOOE+02 2.OOOE+02 1.OOOE+02 1.OOOE+02 4.OOOE+02 1.OOOE+04 1.OOOE+04 1.OOOE+04 3.300E+02 3.300E+02 3.300E+02 3.300E+02 1.OOOE+03 1.OOOE+03 1.OOOE+03 1.OOOE+02 1.OOOE+02 1.OOOE+02 I.OOOE+02 1.OOOE+03 1.OOOE+03 1.000E+03 1.000E+03 1.000E+03 6.700E+OO 6.700E+OO 1.OOOE+02 1.OOOE+02 1.OOOE+O1 5.OOOE+OO 5.000E+OO 3.OOOE+02 3.000E+02 3.OOOE+02 O.OOOE+OO 9.OOOE-Ol 1.800E+03 6.700E-02 2.900E+04 4.OOOE+02 5.500E+02 5.500E+02 3.OOOE+03 3.000E+03 1.OOOE+02 1.OOOE+02 I.OOOE+02 I.OOOE+02 1.OOOE+02 6.700E+02 2.000E+03 2.000E+03 2.000E+03 1.500E-02 1.500E-02 1.500E-02 1.500E-02 8.300E+OO 8.300E+OO 8.300E+OO 2.000E+OO 2.000E+OO 2.OOOE+OO 2.OOOE+OO 2.500E+O1 2.500E+Ol1 2.500E+O1 2.500E+O1 2.500E+O1 2.OOOE+02 2.OOOE+02 3.000E+04 3.000E+04 1.OOOE+O1 l1.OOOE+O1 l1.OOOE+O1 3.OOOE+OO 3.000E+OO 3.000E+OO O.OOOE+OO 9.300E-O1 1.400E+03 1.900E-O1 3.OOOE+04 2.OOOE+03 4.OOOE+02 4.000E+02 2.OOOE+04 2.OOOE+04 1.OOOE+03 l.OOOE+03 I.OOOE+03 2.500E+02 2.500E+02 1.700E+03 5.OOOE+04 5.OOOE+04 5.OOOE+04 3.1 OOE+OO 3.1OOE+OO 3.1OOE+OO

3. I OOE+OO 1.700E+Ol1 1.700E+O1 1.700E+O1 2.OOOE+O1 2.OOOE+O1 2.OOOE+O1 2.OOOE+O 1 1.OOOE+03 1.OOOE+03 1.OOOE+03 1.OOOE+03 1.OOOE+03 8.OOOE+O1 8.000E+Ol 1.OOOE+02 1.OOOE+02 1.OOOE+O1 5.OOOE+O1 5.000E+O1 1.OOOE+03 l.OOOE+03 l.OOOE+03 O.OOOE+OO RSP-0008 REV-13 PAGE 57 OF 104

INFORMATION USE ATTACHMENT 12 PAGE 2 OF 2 TABLE G-3: BIOACCUMULATION FACTORS Nuclide SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 I-130 1-131 1-132 1-133 I-134 I-135 CS-134 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 W-187 NP-239 RH-105 Freshwater Fish O.OOOE+00 0.OOOE+0O 4.OOOE+02 4.OOOE+02 4.OOOE+02 4.OOOE+02 4.OOOE+02 4.000E+02 4.OOOE+02 4.000E+02 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+O1 1.500E+O1 2.OOOE+03 2.OOOE+03 2.OOOE+03 2.OOOE+03 4.OOOE+O0 4.000E+00 4.000E+00 4.OOOE+00 2.500E+O1 2.500E+O1 1.OOOE+00 1.OOOE+O0 1.OOOE+00 2.500E+OI 2.500E+Ol 2.500E+01 1.200E+03 l.OOOE+0l 1.OOOE+O1 Freshwater Non-Fish O.OOOE+00 O.OOOE+O0

6. 100E+03 6.100E+03 6.100E+03 6.100E+03 6.100E+03 6.1 OOE+03 6.1 00E+03 6.1 OOE+03 5.OOOE+O0 5.000E+00 5.OOOE+O0 5.OOOE+O0 5.000E+O0 5.000E+OO 1.OOOE+03 I.000E+03 1.OOOE+03 1.OOOE+03 2.000E+02 2.OOOE+02 2.OOOE+02 2.OOOE+02 1.OOOE+03 1.OOOE+03 1.OOOE+03 1.OOOE+03 1.OOOE+03 1.OOOE+03 I.OOOE+03 1.OOOE+03 l.OOOE+01 4.OOOE+02 3.OOOE+02 Saltwater Fish Saltwater Non-Fish O.OOOE+00 O.OOOE+00 1.OOOE+03 l.OOOE+01 l.OOOE+01 l1.OOOE+01 1.OOOE+O1 1.OOOE+01 l.OOOE+01 1.OOOE+01 1.OOOE+01 1.OOOE+O1 1.OOOE+O1 1.OOOE+01 1.OOOE+01 1.OOOE+01 4.OOOE+O1 4.OOOE+01 4.OOOE+01 4.OOOE+01 1.OOOE+O1 1.OOOE+O1 l.OOOE+01 1.OOOE+01 2.500E+0l 2.500E+01 1.OOOE+01 1.OOOE+01 1.OOOE+01 2.500E+01 2.500E+0I 2.500E1+O1 3.OOOE+01 l.OOOE+01 1.OOOE+01 O.OOOE+00 O.OOOE+O0 1.OOOE+02 1.OOOE+02 l.OOOE+02 1.OOOE+02 1.OOOE+02 1.OOOE+02 l.OOOE+02 1.OOOE+02 5.OOOE+01 5.OOOE+O1 5.OOOE+Ol 5.OOOE+01 5.OOOE+0l 5.OOOE+01 2.500E+O1 2.500E+Ol 2.500E+0l 2.500E+O1 l.OOOE+02 1.OOOE+02 1.OOOE+02 1.OOOE+02 1.OOOE+03 1.OOOE+03 6.OOOE+02 6.OOOE+02 6.000E+02 1.OOOE+03 l.OOOE+03 1.OOOE+03 3.OOOE+01 l.OOOE+01 2.OOOE+03 Units --> pCi/kg per pCi/liter RSP-0008 REV -13 PAGE 58 OF 104

INFORMATION USE ATTACHMENT 13 PAGE I OF 1 TABLE G-4: INDIVIDUAL USAGE FACTORS TABLE G-4 INDIVIDUAL USAGE FACTORS Description Infant Child Teenager Adult Units Fresh Non-fish Drinking Water Milk Shoreline Rec.

Fresh Fish Fresh Leafy Veg.

Stored Veg.

Irrigated Veg.

Breathing Meat O.OOOE+00 3.300E+02 3.300E+02 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.400E+03 O.OOOE+00 1.700E+00 5.100E+02 3.300E+02 1.400E+01 6.900E+00 2.600E+01 5.200E+02 2.600E+01 3.700E+03 4.100E+01 3.800E+00 5.100E+02 4.OOOE+02 6.700E+01 1.600E+01 4.200E+01 6.300E+02 4.200E+01 8.000E+03 6.500E+01 5.OOOE+00 7.300E+02 3.100E+02 1.200E+01 2.100E+O1 6.400E+01 5.200E+02 6.400E+01 8.OOOE+03 1.100E+02 kg/year liters/year liters/year hours/year kg/year kg/year kg/year kg/year m3/year kg/year RSP-0008 REV-13 PAGE 59 OF 104

INFORMATION USE ATTACHMENT 14 PAGE lOF1 TABLE H-i: ASSUMPTIONS/PARAMETERS FOR DOSES TO A MEMBER OF THE PUBLIC INSIDE SITE BOUNDARY TABLE H-1 NOTE This table contains default location, distance, sector and duration information. Other locations and variables could be used if they are more limiting and will be documented in the Annual Radiological Effluent Reportfor the applicable year if needed.

ASSUMPTIONS/PARAMETERS FOR DOSES TO A MEMBER OF THE PUBLIC INSIDE SITE BOUNDARY MEMBER OF LOCATION DISTANCE (1)

SECTOR DURATION THE PUBLIC METERS Private Driver North Parking Lot 275 N

125(3)

Employee Service Building 115(2)

ENE 5

People Entering Alligator Bayou 2500 SW 40 Site Without Consent Casual Drivers Main Admin.

500 WNW 76(4)

Building (1) The approximate distance from main plant vent exhaust to location.

(2)Midpoint of building.

(3)An individual is assumed to be on site 0.25/hr in the morning and 0.25/hr in the evening, 5 days per week, 50 weeks per year (0.5 hr/day *5 days/week

  • 50 weeks/year = 125 hours0.00145 days <br />0.0347 hours <br />2.066799e-4 weeks <br />4.75625e-5 months <br />).

(4)An individual is assumed to be on site.5 hr/day.

(5)Liquid pathways dose is not considered due to nature of activities that individuals are engaged in.

(6) Evaluate the dose, if applicable, to the National Guard/State Police while stationed on site as a member of the public.

RSP-0008 REV-13 PAGE 60 OF 104

INFORMATION USE ATTACHMENT 15 PAGE 1 OF 2 TABLE I-1: DOSE FACTOR TABLE: P (I) - ADULT, INHALATION TABLE I-1 DOSE FACTOR TABLE: P (i) - Adult, inhalation Nuclide Bone Liver H-3 O.OOE+OO 1.26E+03 C-14 1.82E+04 3.41E+03 NA-24 1.02E+04 1.02E+04 P-32 1.32E+06 7.71E+04 CR-51 O.OOE+OO O.OOE+OO MN-S4 O.OOE+OO 3.96E+04 MN-56 O.OOE+OO 1.24E+OO FE-55 2.46E+04 1.70E+04 FE-59 1.18E+04 2.78E+04 CO-57 O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 1.58E+03 CO-60 O.OOE+OO 1.15E+04 NI-63 4.32E+05 3.14E+04 NI-65 1.54E+00 2.10E-O1 CU-64 O.OOE+OO 1.46E+OO ZN-65 3.24E+04 1.03E+05 ZN-69 3.38E-02 6.51E-02 ZN-69M O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 1.35E+05 RB-88 O.OOE+OO 3.87E+02 RB-89 O.OOE+OO 2.56E+02 SR-89 3.04E+05 O.OOE+OO SR-90 9.92E+07 O.OOE+OO SR-91 6.19E+O1 O.OOE+OO SR-92 6.74E+OO O.OOE+OO Y-90 2.09E+03 O.OOE+OO Y-91M 2.61E-O1 O.OOE+OO Y-91 4.62E+05 O.OOE+OO Y-92 1.03E+O1 O.OOE+OO Y-93 9.44E+O1 O.OOE+OO ZR-95 1.07E+05 3.44E+04 ZR-97 9.68E+01 1.96E+O1 NB-95 1.41E+04 7.82E+03 NB-97 O.OOE+OO O.OOE+OO MO-99 O.OOE+OO 1.21E+02 TC-99M 1.03E-03 2.91E-03 TC-1O1 4.18E-05 6.02E-05 RU-103 1.53E+03 O.OOE+OO RU-105 7.90E-O1 O.OOE+OO RU-106 6.91E+04 O.OOE+OO AG-I IOM 1.08E+04 1.OOE+04 SB-124 O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO TE-125M 3.42E+03 1.58E+03 TE-127M 1.26E+04 5.77E+03 TE-127 1.40E+00 6.42E-O1 TE-129M 9.76E+03 4.67E+03 TE-129 4.98E-02 2.39E-02 Units are mrem/yr per pCi/cu.m.

Tbody Thyroid Kidney 1.26E+03 1.26E+03 1.26E+03 3.41E+03 3.41E+03 3.41E+03 1.02E+04 1.02E+04 1.02E+04 5.01E+04 O.OOE+OO O.OOE+OO 1.OOE+02 5.95E+01 2.28E+O1 6.30E+03 O.OOE+OO 9.84E+03 1.83E-O1 O.OOE+OO 1.30E+OO 3.94E+03 O.OOE+OO O.OOE+OO 1.06E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.07E+03 O.OOE+OO O.OOE+OO 1.48E+04 O.OOE+OO O.OOE+00 1.45E+04 O.OOE+OO O.OOE+OO 9.12E-02 O.OOE+OO O.OOE+OO 6.15E-O1 O.OOE+OO 4.62E+OO 4.66E+04 O.OOE+OO 6.90E+04 4.52E-03 O.OOE+OO 4.22E-02 O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.41E+02 O.OOE+OO O.OOE+OO 3.13E+02 O.OOE+OO O.OOE+OO 1.28E+O1 O.OOE+OO O.OOE+OO 5.90E+04 O.OOE+OO O.OOE+OO 1.93E+02 O.OOE+OO O.OOE+OO 1.70E+02 O.OOE+OO O.OOE+OO 8.72E+03 O.OOE+OO O.OOE+OO 6.10E+06 O.OOE+OO O.OOE+OO 2.50E+OO O.OOE+OO O.OOE+OO 2.91E-O1 O.OOE+OO O.OOE+OO 5.61E+O1 O.OOE+OO O.OOE+OO 1.02E-02 O.OOE+OO O.OOE+OO 1.24E+04 O.OOE+OO O.OOE+OO 3.02E-O1 O.OOE+OO O.OOE+OO 2.61E+OO O.OOE+OO O.OOE+OO 2.33E+04 O.OOE+OO 5.42E+04 9.04E+OO O.OOE+OO 2.97E+01 4.21E+03 O.OOE+OO 7.74E+03 O.OOE+OO O.OOE+OO O.OOE+OO 2.30E+01 O.OOE+OO 2.91E+02 3.70E-02 O.OOE+OO 4.42E-02 5.90E-04 O.OOE+OO 1.08E-03 6.58E+02 O.OOE+OO 5.83E+03 3.1 1E-OI O.OOE+OO 1.02E+OO 8.72E+03 O.OOE+OO 1.34E+05 5.94E+03 O.OOE+OO 1.97E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.67E+02 1.05E+03 1.24E+04 1.57E+03 3.29E+03 4.58E+04 3.10E-01 1.06E+00 5.10E+OO 1.58E+03 3.44E+03 3.66E+04 1.24E-02 3.90E-02 1.87E-OI Lung 1.26E+03 3.41E+03 1.02E+04 O.OOE+OO 1.44E+04 1.40E+06 9.44E+03 7.21E+04 1.02E+06 O.OOE+OO 9.28E+05 5.97E+06 1.78E+05 5.60E+03 6.78E+03 8.64E+05 9.20E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.40E+06 9.60E+06 3.65E+04 1.65E+04 1.70E+05 1.92E+03 1.70E+06 1.57E+04 4.85E+04 1.77E+06 7.87E+04 5.05E+05 O.OOE+OO 9.12E+04 7.64E+02 3.99E+02 5.05E+05 1.1OE+04 9.36E+06 4.63E+06 O.OOE+OO O.OOE+OO 3.14E+05 9.60E+05 6.15E+03 1.16E+06 1.94E+03 GI Tract 1.26E+03 3.41E+03 1.02E+04 8.64E+04 3.32E+03 7.74E+04 2.02E+04 6.03E+03 1.88E+05 O.OOE+OO 1.06E+05 2.85E+05 1.34E+04 1.23E+04 4.90E+04 5.34E+04 1.63E+O1 O.OOE+OO O.OOE+OO 2.32E+02 1.64E-03 8.00E-15 1.66E+04 3.34E-09 9.28E-12 3.50E+05 7.22E+05 1.91E+05 4.30E+04 5.06E+05 1.33E+OO 3.85E+05 7.35E+04 4.22E+05 1.50E+05 5.23E+05 1.04E+05 O.OOE+OO 2.48E+05 4.16E+03 1.09E-1 1 1.10E+05 4.82E+04 9.12E+05 3.02E+05 O.OOE+OO O.OOE+OO 7.06E+04 1.50E+05 5.74E+04 3.83E+05 1.57E+02 Skin O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RSP-0008 REV-13 PAGE 61 OF 104

i INFORMATION USE ATTACHMENT 15 PAGE 2 OF 2 TABLE I-1: DOSE FACTOR TABLE: P (I) - ADULT, INHALATION Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 6.99E+01 4.36E+01 2.90E+01 5.50E+01 3.09E+02 1.46E+05 5.56E+05 O.OOE+00 TE-131 l.llE-02 5.95E-03 3.59E-03 9.36E-03 4.37E-02 1.39E+03 1.84E+01 O.OOE+00 TE-132 2.60E+02 2.15E+02 1.62E+02 1.90E+02 1.46E+03 2.88E+05 5.10E+05 O.OOE+00 1-130 4.58E+03 1.34E+04 5.28E+03 1.14E+06 2.09E+04 O.OOE+00 7.69E+03 O.OOE+00 1-131 2.52E+04 3.58E+04 2.05E+04 1.19E+07 6.13E+04 O.OOE+00 6.28E+03 O.OOE+00 1-132 1.16E+03 3.26E+03 1.16E+03 1.14E+05 5.18E+03 O.OOE+00 4.06E+02 O.OOE+00 I-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 O.OOE+00 8.88E+03 O.OOE+00 I-134 6.44E+02 1.73E+03 6.15E+02 2.98E+04 2.75E+03 O.OOE+00 1.O1E+00 O.OOE+00 I-135 2.68E+03 6.98E+03 2.57E+03 4.48E+05 1.llE+04 O.OOE+00 5.25E+03 O.OOE+00 CS-134 3.73E+05 8.48E+05 7.28E+05 O.OOE+00 2.87E+05 9.76E+04 1.04E+04 O.OOE+00 CS-136 3.90E+04 1.46E+05 l.lOE+05 O.OOE+00 8.56E+04 1.20E+04 1.17E+04 O.OOE+00 CS-137 4.78E+05 6.21E+05 4.28E+05 O.OOE+00 2.22E+05 7.52E+04 8.40E+03 O.OOE+00 CS-138 3.31E+02 6.21E+02 3.24E+02 O.OOE+00 4.80E+02 4.86E+01 1.86E-03 O.OOE+00 BA-139 9.36E-01 6.66E-04 2.74E-02 O.OOE+00 6.22E-04 3.76E+03 8.96E+02 O.OOE+00 BA-140 3.90E+04 4.90E+01 2.57E+03 O.OOE+00 1.67E+01 1.27E+06 2.18E+05 O.OOE+00 BA-141 1.OOE-01 7.53E-05 3.36E-03 O.OOE+00 7.OOE-05 1.94E+03 1.16E-07 O.OOE+00 BA-142 2.63E-02 2.70E-05 1.66E-03 O.OOE+00 2.29E-05 1.19E+03 1.57E-16 O.OOE+00 LA-140 3.44E+02 1.74E+02 4.58E+01 O.OOE+00 O.OOE+00 1.36E+05 4.58E+05 O.OOE+00 LA-142 6.83E-01 3.10E-01 7.72E-02 O.OOE+00 O.OOE+00 6.33E+03 2.11E+03 O.OOE+00 CE-141 1.99E+04 1.35E+04 1.53E+03 O.OOE+00 6.26E+03 3.62E+05 1.20E+05 O.OOE+00 CE-143 1.86E+02 1.38E+02 1.53E+01 O.OOE+00 6.08E+01 7.98E+04 2.26E+05 O.OOE+00 CE-144 3.43E+06 1.43E+06 1.84E+05 O.OOE+00 8.48E+05 7.78E+06 8.16E+05 O.OOE+00 PR-143 9.36E+03 3.75E+03 4.64E+02 O.OOE+00 2.16E+03 2.81E+05 2.OOE+05 O.OOE+00 PR-144 3.01E-02 1.25E-02 1.53E-03 O.OOE+00 7.05E-03 1.02E+03 2.15E-08 O.OOE+00 ND-147 5.27E+03 6.10E+03 3.65E+02 O.OOE+00 3.56E+03 2.21E+05 1.73E+05 O.OOE+00 W-187 8.48E+00 7.08E+00 2.48E+00 O.OOE+00 O.OOE+00 2.90E+04 1.50E+05 O.OOE+00 NP-239 2.30E+02 2.26E+01 1.24E+01 O.OOE+00 7.OOE+01 3.76E+04 1.19E+05 O.OOE+00 RSP-0008 REV-13 PAGE 62 OF 104

INFORMATION USE ATTACHMENT 16 PAGE 1 OF 2 TABLE 1-2: DOSE FACTOR TABLE: P (I) - TEEN, INHALATION TABLE I-2 DOSE FACTOR TABLE: P (i) - Teen, inhalation, Units are mrem/yr per gLCicu.m Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 O.OOE+OO C-14 2.60E+04 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 O.OOE+OO NA-24 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 O.OOE+OO P-32 1.89E+06 1.1OE+05 7.16E+04 O.OOE+OO O.OOE+OO O.OOE+OO 9.28E+04 O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 1.35E+02 7.50E+01 3.07E+01 2.10E+04 3.00E+03 O.OOE+OO MN-54 O.OOE+OO 5.1 1E+04 8.40E+03 O.OOE+OO 1.27E+04 1.98E+06 6.68E+04 O.OOE+OO MN-56 O.OOE+OO 1.70E+00 2.52E-O1 O.OOE+OO 1.79E+00 1.52E+04 5.74E+04 O.OOE+OO FE-55 3.34E+04 2.38E+04 5.54E+03 O.OOE+OO O.OOE+OO 1.24E+05 6.39E+03 O.OOE+OO FE-59 1.59E+04 3.70E+04 1.43E+04 O.OOE+OO O.OOE+OO 1.53E+06 1.78E+05 O.OOE+OO CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 2.07E+03 2.78E+03 O.OOE+OO O.OOE+OO 1.34E+06 9.52E+04 O.OOE+OO CO-60 O.OOE+OO 1.51E+04 1.98E+04 O.OOE+OO O.OOE+OO 8.72E+06 2.59E+05 O.OOE+OO NI-63 5.80E+05 4.34E+04 1.98E+04 O.OOE+OO O.OOE+OO 3.07E+05 1.42E+04 O.OOE+OO NI-65 2.18E+00 2.93E-01 1.27E-O1 O.OOE+00 O.OOE+OO 9.36E+03 3.67E+03 O.OOE+OO CU-64 O.OOE+OO 2.03E+00 8.48E-O1 O.OOE+OO 6.41E+OO 1.11E+04 6.14E+04 O.OOE+OO ZN-65 3.86E+04 1.34E+05 6.24E+04 O.OOE+OO 8.64E+04 1.24E+06 4.66E+04 O.OOE+OO ZN-69 4.83E-02 9.20E-02 6.46E-03 O.OOE+OO 6.02E-02 1.58E+03 2.85E+02 O.OOE+OO ZN-69M O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 3.44E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 4.33E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO 1.83E+O1 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 1.90E+05 8.40E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.77E+04 O.OOE+OO RB-88 O.OOE+OO 5.46E+02 2.72E+02 O.OOE+OO O.OOE+OO O.OOE+OO 2.92E-05 O.OOE+OO RB-89 O.OOE+OO 3.52E+02 2.33E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.38E-07 O.OOE+OO SR-89 4.34E+05 O.OOE+OO 1.25E+04 O.OOE+OO O.OOE+OO 2.42E+06 3.71E+05 O.OOE+OO SR-90 1.08E+08 O.OOE+OO 6.68E+06 O.OOE+OO O.OOE+OO 1.65E+07 7.65E+05 O.OOE+OO SR-91 8.80E+O1 O.OOE+OO 3.51E+OO O.OOE+OO O.OOE+OO 6.07E+04 2.59E+05 O.OOE+OO SR-92 9.52E+OO O.OOE+OO 4.06E-O1 O.OOE+OO O.OOE+OO 2.74E+04 1.19E+05 O.OOE+OO Y-90 2.98E+03 O.OOE+OO 8.OOE+O1 O.OOE+OO O.OOE+OO 2.93E+05 5.59E+05 O.OOE+OO Y-91M 3.70E-O1 O.OOE+OO 1.42E-02 O.OOE+OO O.OOE+OO 3.20E+03 3.02E+O1 O.OOE+OO Y-91 6.61E+05 O.OOE+OO 1.77E+04 O.OOE+OO O.OOE+OO 2.94E+06 4.09E+05 O.OOE+OO Y-92 1.47E+O1 O.OOE+OO 4.29E-01 O.OOE+OO O.OOE+OO 2.68E+04 1.65E+05 O.OOE+OO Y-93 1.35E+02 O.OOE+OO 3.72E+OO O.OOE+OO O.OOE+OO 8.32E+04 5.79E+05 O.OOE+OO ZR-95 1.46E+05 4.58E+04 3.15E+04 O.OOE+OO 6.74E+04 2.69E+06 1.49E+05 O.OOE+OO ZR-97 1.38E+02 2.72E+01 1.26E+01 O.OOE+OO 4.12E+O1 1.30E+05 6.30E+05 O.OOE+OO NB-95 1.86E1+04 1.03E+04 5.66E+03 O.OOE+OO l.OOE+04 7.51E+05 9.68E+04 O.OOE+OO NB-97 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+OO MO-99 O.OOE+OO 1.69E+02 3.22E+O1 O.OOE+OO 4.11E+02 1.54E+05 2.69E+05 O.OOE+OO TC-99M 1.38E-03 3.86E-03 4.99E-02 O.OOE+OO 5.76E-02 1.15E+03 6.13E+03 O.OOE+OO TC-101 S.92E-05 8.40E-05 8.24E-04 O.OOE+OO 1.52E-03 6.67E+02 8.72E-07 O.OOE+OO RU-103 2.10E+03 O.OOE+OO 8.96E+02 O.OOE+OO 7.43E+03 7.83E+05 1.09E+05 O.OOE+OO RU-105 1.12E+OO O.OOE+OO 4.34E-O1 O.OOE+OO 1.41E+00 1.82E+04 9.04E+04 O.OOE+OO RU-106 9.84E+04 O.OOE+OO 1.24E+04 O.OOE+OO 1.90E+05 1.61E+07 9.60E+05 O.OOE+OO AG-IIOM 1.38E+04 1.31E+04 7.99E+03 O.OOE+OO 2.50E+04 6.75E+06 2.73E+05 O.OOE+OO SB-124 O.OOE+OO O

O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO TE-125M 4.88E+03 2.24E+03 6.67E+02 1.40E+03 O.OOE+OO 5.36E+05 7.50E+04 O.OOE+OO TE-127M 1.80E+04 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 1.59E+05 O.OOE+OO TE-127 2.01E+00 9.12E-01 4.42E-01 1.42E+00 7.28E+00 1.12E+04 8.08E+04 O.OOE+OO TE-129M 1.39E+04 6.58E+03 2.25E+03 4.58E+03 5.19E+04 1.98E+06 4.05E+05 O.OOE+OO TE-129 7.10E-02 3.38E-02 1.76E-02 5.18E-02 2.66E-01 3.30E+03 1.62E+03 O.OOE+OO RSP-0008 REV-13 PAGE 63 OF 104

INFORMATION USE ATTACHMENT 16 PAGE 2 OF 2 TABLE 1-2: DOSE FACTOR TABLE: P (1) - TEEN, INHALATION Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 9.84E+01 6.01E+01 4.02E+01 7.25E+01 4.39E+02 2.38E+05 6.21E+05 O.OOE+0O TE-131 1.58E-02 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 1.51E+01 O.OOE+00 TE-132 3.60E+02 2.90E+02 2.19E+02 2.46E+02 1.95E+03 4.49E+05 4.63E+05 O.OOE+00 1-130 6.24E+03 1.79E+04 7.17E+03 1.49E+06 2.75E+04 O.OOE+O0 9.12E+03 O.OOE+00 1-131 3.54E+04 4.91E+04 2.64E+04 1.46E+07 8.40E+04 O.OOE+00 6.49E+03 O.OOE+00 1-132 1.59E+03 4.38E+03 1.58E+03 1.51E+05 6.92E+03 O.OOE+00 1.27E+03 O.OOE+00 I-133 1.22E+04 2.05E+04 6.22E+03 2.92E+06 3.59E+04 O.OOE+00 1.03E+04 O.OOE+00 1-134 8.88E+02 2.32E+03 8.40E+02 3.95E+04 3.66E+03 O.OOE+O0 2.04E+01 O.OOE+O0 1-135 3.70E+03 9.44E+03 3.49E+03 6.21E+05 1.49E+04 O.OOE+00 6.95E+03 O.OOE+00 CS-134 5.02E+05 1.13E+06 5.49E+05 O.OOE+0O 3.75E+05 1.46E+05 9.76E+03 O.OOE+00 CS-136 5.15E+04 1.94E+05 1.37E+05 O.OOE+O0 1.10E+05 1.78E+04 1.09E+04 O.OOE+00 CS-137 6.70E+05 8.48E+05 3.11E+05 O.OOE+O0 3.04E+05 1.21E+05 8.48E+03 O.OOE+O0 CS-138 4.66E+02 8.56E+02 4.46E+02 O.OOE+O0 6.62E+02 7.87E+01 2.70E-01 O.OOE+00 BA-139 1.34E+00 9.44E-04 3.90E-02 O.OOE+O0 8.88E-04 6.46E+03 6.45E+03 O.OOE+OO BA-140 5.47E+04 6.70E+01 3.52E+03 O.OOE+0O 2.28E+01 2.03E+06 2.29E+05 O.OOE+0O BA-141 1.42E-01 1.06E-04 4.74E-03 O.OOE+OO 9.84E-05 3.29E+03 7.46E-04 O.OOE+0O BA-142 3.70E-02 3.70E-05 2.27E-03 O.OOE+00 3.14E-05 1.91E+03 4.79E-10 O.OOE+00 LA-140 4.79E+02 2.36E+02 6.26E+01 O.OOE+0O O.OOE+OO 2.14E+05 4.87E+05 O.OOE+O0 LA-142 9.60E-01 4.25E-01 1.06E-01 O.OOE+0O O.OOE+00 1.02E+04 1.20E+04 O.OOE+00 CE-141 2.84E+04 1.90E+04 2.17E+03 O.OOE+00 8.88E+03 6.14E+05 1.26E+05 O.OOE+O0 CE-143 2.66E+02 1.94E+02 2.16E+01 O.OOE+0O 8.64E+01 1.30E+05 2.55E+05 O.OOE+O0 CE-144 4.89E+06 2.02E+06 2.62E+05 O.OOE+00 1.21E+06 1.34E+07 8.64E+05 O.OOE+O0 PR-143 1.34E+04 5.31E+03 6.62E+02 O.OOE+00 3.09E+03 4.83E+05 2.14E+05 O.OOE+O0 PR-144 4.30E-02 1.76E-02 2.18E-03 O.OOE+00 1.01E-02 1.75E+03 2.35E-04 O.OOE+O0 ND-147 7.86E+03 8.56E+03 5.13E+02 O.OOE+00 5.02E+03 3.72E+05 1.82E+05 O.OOE+00 W-187 1.20E+01 9.76E+00 3.43E+O0 O.OOE+O0 O.OOE+O0 4.74E+04 1.77E+05 O.OOE+00 NP-239 3.38E+02 3.19E+01 1.77E+01 O.OOE+00 1.00E+02 6.49E+04 1.32E+05 O.OOE+O0 RSP-0008 REV-13 PAGE 64 OF 104

INFORMATION USE ATTACHMENT 17 PAGE 1 OF 2 TABLE 1-3: DOSE FACTOR TABLE: P (I) - CHILD, INHALATION TABLE I-3 DOSE FACTOR TABLE: P (i) - CHILD, inhalation, Units are mrem/yr per,uCi/cu.m Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 O.OOE+OO C-14 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 O.OOE+OO NA-24 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 O.OOE+OO P-32 2.60E+06 1.14E+05 9.88E+04 O.OOE+OO O.OOE+OO O.OOE+OO 4.22E+04 O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 O.OOE+OO MN-54 O.OOE+OO 4.29E+04 9.51E+03 O.OOE+OO 1.OOE+04 1.58E+06 2.29E+04 O.OOE+OO MN-56 O.OOE+OO 1.66E+00 3.12E-OI O.OOE+OO 1.67E+00 1.31E+04 1.23E+05 O.OOE+OO FE-55 4.74E+04 2.52E+04 7.77E+03 O.OOE+OO O.OOE+OO 1.11E+05 2.87E+03 O.OOE+OO FE-59 2.07E+04 3.34E+04 1.67E+04 O.OOE+OO O.OOE+OO 1.27E+06 7.07E+04 O.OOE+OO CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 1.77E+03 3.16E+03 O.OOE+OO O.OOE+OO 1.11E+06 3.44E+04 O.OOE+OO CO-60 O.OOE+OO 1.3 1E+04 2.26E+04 O.OOE+OO O.OOE+OO 7.07E+06 9.62E+04 O.OOE+OO NI-63 8.21E+05 4.63E+04 2.80E+04 O.OOE+OO O.OOE+OO 2.75E+05 6.33E+03 O.OOE+OO NI-65 2.99E+00 2.96E-01 1.64E-O1 O.OOE+OO O.OOE+OO 8.18E+03 8.40E+04 O.OOE+OO CU-64 O.OOE+OO 1.99E+00 1.07E+OO O.OOE+OO 6.03E+00 9.58E+03 3.67E+04 O.OOE+OO ZN-65 4.26E+04 1.13E+05 7.03E+04 O.OOE+OO 7.14E+04 9.95E+05 1.63E+04 O.OOE+OO ZN-69 6.70E-02 9.66E-02 8.92E-03 O.OOE+OO 5.85E-02 1.42E+03 1.02E-04 O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 4.74E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 5.48E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO 2.53E+O1 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 1.98E+05 1.14E+05 O.OOE+OO O.OOE+OO O.OOE+OO 7.99E+03 O.OOE+OO RB-88 O.OOE+OO 5.62E+02 3.66E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.72E+O1 O.OOE+OO RB-89 O.OOE+OO 3.45E+02 2.90E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.89E+OO O.OOE+OO SR-89 5.99E+05 O.OOE+OO 1.72E+04 O.OOE+OO O.OOE+OO 2.16E+06 1.67E+05 O.OOE+OO SR-90 1.O1E+08 O.OOE+OO 6.44E+06 O.OOE+OO O.OOE+OO 1.48E+07 3.43E+05 O.OOE+OO SR-91 1.21E+02 O.OOE+OO 4.59E+OO O.OOE+OO O.OOE+OO 5.33E+04 1.74E+05 O.OOE+OO SR-92 1.31E+O1 O.OOE+OO 5.25E-O1 O.OOE+OO O.OOE+OO 2.40E+04 2.42E+05 O.OOE+OO Y-90 4.1 1E+03 O.OOE+OO 1.11E+02 O.OOE+OO O.OOE+OO 2.62E+05 2.68E+05 O.OOE+OO Y-91M 5.07E-O1 O.OOE+OO 1.84E-02 O.OOE+OO O.OOE+OO 2.81E+03 1.72E+03 O.OOE+OO Y-91 9.14E+05 O.OOE+OO 2.44E+04 O.OOE+OO O.OOE+OO 2.63E+06 1.84E+05 O.OOE+OO Y-92 2.04E+01 O.OOE+OO 5.81E-O1 O.OOE+OO O.OOE+OO 2.39E+04 2.39E+05 O.OOE+OO Y-93 1.86E+02 O.OOE+OO 5.11E+OO O.OOE+OO O.OOE+OO 7.44E+04 3.89E+05 O.OOE+OO ZR-95 1.90E+05 4.18E+04 3.70E+04 O.OOE+OO 5.96E+04 2.23E+06 6.11E+04 O.OOE+OO ZR-97 1.88E+02 2.72E+01 1.60E+O1 O.OOE+OO 3.88E+01 1.13E+05 3.51E+05 O.OOE+OO NB-95 2.35E+04 9.18E+03 6.55E+03 O.OOE+OO 8.62E+03 6.14E+05 3.70E+04 O.OOE+OO NB-97 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO MO-99 O.OOE+OO 1.72E+02 4.25E+O1 O.OOE+OO 3.92E+02 1.35E+05 1.27E+05 O.OOE+OO TC-99M 1.78E-03 3.48E-03 5.77E-02 O.OOE+OO 5.07E-02 9.51E+02 4.81E+03 O.OOE+OO TC-101 8.10E-05 8.51E-05 1.08E-03 O.OOE+OO 1.45E-03 5.85E+02 1.63E+O1 O.OOE+OO RU-103 2.79E+03 O.OOE+OO 1.07E+03 O.OOE+OO 7.03E+03 6.62E+05 4.48E+04 O.OOE+OO RU-105 1.53E+OO O.OOE+OO 5.55E-O1 O.OOE+OO 1.34E+00 1.59E+04 9.95E+04 O.OOE+OO RU-106 1.36E+05 O.OOE+OO 1.69E+04 O.OOE+OO 1.84E+05 1.43E+07 4.29E+05 O.OOE+OO AG-llOM 1.69E+04 1.14E+04 9.14E+03 O.OOE+OO 2.12E+04 5.48E+06 1.OOE+05 O.OOE+OO SB-124 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 6.73E+03 2.33E+03 9.14E+02 1.92E+03 O.OOE+OO 4.77E+05 3.38E+04 O.OOE+OO TE-127M 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 O.OOE+OO TE-127 2.77E+00 9.51E-01 6.10E-01 1.96E+00 7.07E+OO 1.OOE+04 5.62E+04 O.OOE+OO TE-129M 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 O.OOE+OO TE-129 9.77E-02 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 2.55E+04 O.OOE+OO RSP-0008 REV-13 PAGE 65 OF 104

INFORMATION USE ATTACHMENT 17 PAGE 2 OF 2 TABLE 1-3: DOSE FACTOR TABLE: P (I) - CHIULD, INHALATION Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 1.34E+02 5.92E+01 5.07E+01 9.77E+01 4.00E+02 2.06E+05 3.08E+05 0.OOE+00 TE-131 2.17E-02 8.44E-03 6.59E-03 1.70E-02 5.88E-02 2.05E+03 1.33E+03 0.OOE+O0 TE-132 4.81E+02 2.72E+02 2.63E+02 3.17E+02 1.77E+03 3.77E+05 1.38E+05 0.OOE+00 I-130 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 0.OOE+00 5.11E+03 0.OOE+0O 1-131 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 0.OOE+00 2.84E+03 0.OOE+00 1-132 2.12E+03 4.07E+03 1.88E+03 1.94E+05 6.25E+03 O.OOE+00 3.20E+03 O.OOE+O0 1-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 0.OOE+00 5.48E+03 O.OOE+00 1-134 1.17E+03 2.16E+03 9.95E+02 5.07E+04 3.30E+03 0.OOE+00 9.SSE+02 0.OOE+00 1-135 4.92E+03 8.73E+03 4.14E+03 7.92E+05 1.34E+04 0.OOE+00 4.44E+03 0.OOE+00 CS-134 6.51E+05 1.O1E+06 2.25E+05 0.OOE+00 3.30E+05 1.21E+05 3.85E+03 0.OOE+00 CS-136 6.51E+04 1.71E+05 1.16E+05 O.OOE+00 9.55E+04 1.45E+04 4.18E+03 O.OOE+00 CS-137 9.07E+05 8.25E+05 1.28E+05 0.OOE+00 2.82E+05 1.04E+05 3.62E+03 0.OOE+00 CS-138 6.33E+02 8.40E+02 5.55E+02 0.OOE+00 6.22E+02 6.81E+01 2.70E+02 0.OOE+00 BA-139 1.84E+00 9.84E-04 5.36E-02 0.OOE+00 8.62E-04 5.77E+03 5.77E+04 O.OOE+00 BA-140 7.40E+04 6.48E+01 4.33E+03 O.OOE+00 2.1 IE+01 1.74E+06 1.02E+05 O.OOE+O0 BA-141 1.96E-01 1.09E-04 6.36E-03 0.OOE+00 9.47E-05 2.92E+03 2.75E+02 0.OOE+00 BA-142 4.99E-02 3.60E-05 2.79E-03 0.OOE+00 2.91E-05 1.64E+03 2.74E+00 0.OOE+00 LA-140 6.44E+02 2.25E+02 7.55E+01 0.OOE+00 0.OOE+O0 1.83E+05 2.26E+05 O.OOE+00 LA-142 1.29E+00 4.1 IE-01 1.29E-01 0.OOE+00 0.OOE+00 8.70E+03 7.59E+04 O.OOE+00 CE-141 3.92E+04 1.95E+04 2.90E+03 0.OOE+00 8.55E+03 5.44E+05 5.66E+04 O.OOE+00 CE-143 3.66E+02 1.99E+02 2.87E+01 0.OOE+00 8.36E+01 1.15E+05 1.27E+05 0.OOE+00 CE-144 6.77E+06 2.12E+06 3.61E+05 0.OOE+00 1.17E+06 1.20E+07 3.89E+05 0.OOE+00 PR-143 1.85E+04 5.55E+03 9.14E+02 0.OOE+00 3.OOE+03 4.33E+05 9.73E+04 0.OOE+00 PR-144 5.96E-02 1.85E-02 3.OOE-03 0.OOE+00 9.77E-03 1.57E+03 1.97E+02 O.OOE+O0 ND-147 1.08E+04 8.73E+03 6.81E+02 0.OOE+00 4.81E+03 3.28E+05 8.21E+04 0.OOE+00 W-187 1.63E+01 9.66E+00 4.33E+00 0.OOE+00 0.OOE+00 4.1 IE+04 9.10E+04 0.OOE+00 NP-239 4.66E+02 3.34E+01 2.35E+01 0.OOE+00 9.73E+01 5.81E+04 6.40E+04 0.OOE+00 RSP-0008 REV-13 PAGE 66 OF 104

INFORMATION USE ATTACHMENT 18 PAGE 1 OF 2 TABLE I-4: DOSE FACTOR TABLE: P (1) - INFANT, INHALATION TABLE 1-4 DOSE FACTOR TABLE: P (i) - Infant, inhalation, Units are mrem/yr per gCi/cu.m Nuclide Bone Liver Tbody Thyroid Kidney Lujng GI Tract Skin H-3 O.OOE+OO 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 O.OOE+OO C-14 2.65E+04 5.31E+03 5.31E+03 5.31E+03 5.31E+03 5.31E+03 5.31E+03 O.OOE+OO NA-24 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 O.OOE+OO P-32 2.03E+06 1.12E+05 7.74E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.61E+04 O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 8.95E+01 5.75E+01 1.32E+01 1.28E+04 3.57E+02 O.OOE+OO MN-54 O.OOE+OO 2.53E+04 4.98E+03 O.OOE+OO 4.98E+03 1.OOE+06 7.06E+03 O.OOE+OO MN-56 O.OOE+OO 1.54E+00 2.21E-O1 O.OOE+OO 1.10E+00 1.25E+04 7.17E+04 O.OOE+OO FE-55 1.97E+04 1.17E+04 3.33E+03 O.OOE+OO O.OOE+OO 8.69E+04 1.09E+03 O.OOE+OO FE-59 1.36E+04 2.35E+04 9.48E+03 O.OOE+OO O.OOE+OO 1.02E+06 2.48E+04 O.OOE+OO CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 1.22E+03 1.82E+03 O.OOE+OO O.OOE+OO 7.77E+05 1.11E+04 O.OOE+OO CO-60 O.OOE+OO 8.02E+03 1.18E+04 O.OOE+OO O.OOE+OO 4.51E+06 3.19E+04 O.OOE+OO NI-63 3.39E+05 2.04E+04 1.16E+04 O.OOE+OO O.OOE+OO 2.09E+05 2.42E+03 O.OOE+OO NI-65 2.39E+00 2.84E-01 1.23E-O1 O.OOE+OO O.OOE+OO 8.12E+03 5.01E+04 O.OOE+OO CU-64 O.OOE+OO 1.88E+00 7.74E-O1 O.OOE+OO 3.98E+00 9.30E+03 1.50E+04 O.OOE+OO ZN-65 1.93E+04 6.26E+04 3.11E+04 O.OOE+OO 3.25E+04 6.47E+05 5.14E+04 O.OOE+OO ZN-69 5.39E-02 9.67E-02 7.18E-03 O.OOE+OO 4.02E-02 1.47E+03 1.32E+04 O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 3.81E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 4.OOE+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO 2.04E+O1 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 1.90E+05 8.82E+04 O.OOE+OO O.OOE+OO O.OOE+OO 3.04E+03 O.OOE+OO RB-88 O.OOE+OO 5.57E+02 2.87E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.39E+02 O.OOE+OO RB-89 O.OOE+OO 3.21E+02 2.06E+02 O.OOE+OO O.OOE+OO O.OOE+OO 6.82E+O1 O.OOE+OO SR-89 3.98E+05 O.OOE+OO 1.14E+04 O.OOE+OO O.OOE+OO 2.03E+06 6.40E+04 O.OOE+OO SR-90 4.09E+07 O.OOE+OO 2.59E+06 O.OOE+OO O.OOE+OO 1.12E+07 1.31E+05 O.OOE+OO SR-91 9.56E+O1 O.OOE+OO 3.46E+OO O.OOE+OO O.OOE+OO 5.26E+04 7.34E+04 O.OOE+OO SR-92 1.05E+O1 O.OOE+OO 3.91E-O1 O.OOE+OO O.OOE+OO 2.38E+04 1.40E+05 O.OOE+OO Y-90 3.29E+03 O.OOE+OO 8.82E+O1 O.OOE+OO O.OOE+OO 2.69E+05 1.04E+05 O.OOE+OO Y-91M 4.07E-O1 O.OOE+OO 1.39E-02 O.OOE+OO O.OOE+OO 2.79E+03 2.35E+03 O.OOE+OO Y-91 5.88E+05 O.OOE+OO 1.57E+04 O.OOE+OO O.OOE+OO 2.45E+06 7.03E+04 O.OOE+OO Y-92 1.64E+O1 O.OOE+OO 4.61E-O1 O.OOE+OO O.OOE+OO 2.45E+04 1.27E+05 O.OOE+OO Y-93 1.50E+02 O.OOE+OO 4.07E+OO O.OOE+OO O.OOE+OO 7.64E+04 1.67E+05 O.OOE+OO ZR-95 1.15E+05 2.79E+04 2.03E+04 O.OOE+OO 3.11E+04 1.75E+06 2.17E+04 O.OOE+OO ZR-97 1.50E+02 2.56E+01 1.17E+O1 O.OOE+OO 2.59E+O1 1.1OE+05 1.40E+05 O.OOE+OO NB-95 1.57E+04 6.43E+03 3.78E+03 O.OOE+OD 4.72E+03 4.79E+05 1.27E+04 O.OOE+OO NB-97 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO MO-99 O.OOE+OO 1.65E+02 3.23E+O1 O.OOE+OO 2.65E+02 1.35E+05 4.87E+04 O.OOE+OO TC-99M 1.40E-03 2.88E-03 3.72E-02 O.OOE+OO 3.11E-02 8.1 1E+02 2.03E+03 O.OOE+OO TC-1O1 6.51E-05 8.23E-05 8.12E-04 O.OOE+OO 9.79E-04 5.84E+02 8.44E+02 O.OOE+OO RU-103 2.02E+03 O.OOE+OO 6.79E+02 O.OOE+OO 4.24E+03 5.52E+05 1.61E+04 O.OOE+OO RU-105 1.22E+OO O.OOE+OO 4.10E-O1 O.OOE+OO 8.99E-01 1.57E+04 4.84E+04 O.OOE+OO RU-106 8.68E+04 O.OOE+OO 1.09E+04 O.OOE+OO 1.07E+05 1.16E+07 1.64E+05 O.OOE+OO AG-1 IOM 9.98E+03 7.22E+03 5.OOE+03 O.OOE+OO 1.09E+04 3.67E+06 3.30E+04 O.OOE+OO SB-124 O.OOE+OO O.OOE+OO -

O.OOE+O0 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO Q.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 4.76E+03 1.99E+03 6.S8E+02 1.62E+03 O.OOE+OO 4.47E+05 1.29E+04 O.OOE+OO TE-127M 1.67E+04 6.90E+03 2.07E+03 4.87E+03 3.75E+04 1.31E+06 2.73E+04 O.OOE+OO TE-127 2.23E+00 9.53E-01 4.89E-01 1.85E+00 4.86E+00 1.03E+04 2.44E+04 O.OOE+OO TE-129M 1.41E+04 6.09E+03 2.23E+03 5.47E+03 3.18E+04 1.68E+06 6.90E+04 O.OOE+OO TE-129 7.88E-02 3.47E-02 1.88E-02 6.75E-02 1.75E-01 3.OOE+03 2.63E+04 O.OOE+OO RSP-0008 REV -13 PAGE 67 OF 104

INFORMATION USE ATTACHMENT 18 PAGE 2 OF 2 TABLE 1-4: DOSE FACTOR TABLE: P (I) - INFANT, INHALATION Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 1.07E+02 5.50E+01 3.63E+01 8.93E+01 2.65E+02 TE-131 1.74E-02 8.22E-03 5.OOE-03 1.58E-02 3.99E-02 TE-132 3.72E+02 2.37E+02 1.76E+02 2.79E+02 1.03E+03 I-130 6.36E+03 1.39E+04 5.57E+03 1.60E+06 1.53E+04 1-131 3.79E+04 4.44E+04 1.96E+04 1.48E+07 5.18E+04 1-132 1.69E+03 3.54E+03 1.26E+03 1.69E+05 3.95E+03 1-133 1.32E+04 1.92E+04 5.60E+03 3.56E+06 2.24E+04 1-134 9.21E+02 1.88E+03 6.65E+02 4.45E+04 2.90E+03 I-135 3.86E+03 7.60E+03 2.77E+03 6.96E+05 8.47E+03 CS-134 3.96E+05 7.03E+05 7.45E+04 O.OOE+00 1.90E+05 CS-136 4.83E+04 1.35E+05 5.29E+04 O.OOE+00 5.64E+04 CS-137 5.49E+05 6.12E+05 4.55E+04 0.OOE+00 1.72E+05 CS-138 5.05E+02 7.81E+02 3.98E+02 O.OOE+00 4.1OE+02 BA-139 1.48E+00 9.84E-04 4.30E-02 0.OOE+00 5.92E-04 BA-140 5.60E+04 5.60E+01 2.90E+03 O.OOE+00 1.34E+01 BA-141 1.57E-01 1.08E-04 4.97E-03 O.OOE+00 6.50E-05 BA-142 3.98E-02 3.30E-05 1.96E-03 0.OOE+00 1.90E-05 LA-140 5.05E+02 2.OOE+02 5.15E+01 0.OOE+00 O.OOE+00 LA-142 1.03E+00 3.77E-01 9.04E-02 O.OOE+00 O.OOE+00 CE-141 2.77E+04 1.67E+04 1.99E+03 O.OOE+00 5.25E+03 CE-143 2.93E+02 1.93E+02 2.21E+01 O.OOE+00 5.64E+01 CE-144 3.19E+06 1.21E+06 1.76E+05 O.OOE+00 5.38E+05 PR-143 1.40E+04 5.24E+03 6.99E+02 O.OOE+00 1.97E+03 PR-144 4.79E-02 1.85E-02 2.41E-03 O.OOE+00 6.72E-02 ND-147 7.94E+04 8.13E+03 5.OOE+02 O.OOE+00 3.15E+03 W-187 1.30E+01 9.02E+00 3.12E+00 O.OOE+00 O.OOE+00 NP-239 3.71E+02 3.32E+01 1.88E+01 O.OOE+00 6.62E+01 1.99E+05 2.06E+03 3.40E+05 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 7.97E+04

1. 181E+04 7.13E+04 6.54E+01 5.95E+03 1.60E+06 2.97E+03 1.55E+03 1.68E+05 8.22E+03 5.17E+05 1.16E+05 9.84E+06 4.33E+05 1.61E+03 3.22E+05 3.96E+04
1. 19E1+05 8.22E+03 4.41E+04 1.99E3+03 1.06E+03 1.90E+03 2.16E+03 1.29E+03 1.83E+03 1.33E+03 1.43E+03 1.33E+03 8.76E+02 5.10E+04 3.84E+04 4.75E+03 6.93E+02 8.48E+04 5.951E+04 2.16E+04 4.97E+04 1.48E+05 3.721E+04 4.28E+03 3.12E+04 3.56E+04 0.OOE+00 0.OOE+O0 0.OO1+O00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE1+00 O.OOE+O0 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE1+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+O0 O.OOE+O0 5.95E+04 2.49E+04 RSP-0008 REV-13 PAGE 68 OF 104

INFORMATION USE ATTACHMENT 19 PAGE 1 OF 2 TABLE 1-5: DOSE FACTOR TABLE: R (I) - ALL, GR. PLANE TABLE 1-5 DOSE FACTOR TABLE: R (i) -All, gr. plane, Units are m2 *mrem/yr per liCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO O.OOE+OO C-14 O.OOE+OO O.OOE+OO NA-24 1.19E+07 1.19E+07 P-32 O.OOE+OO O.OOE+OO CR-51 4.66E+06 4.66E+06 MN-54 1.39E+09 1.39E+09 MN-56 9.03E+05 9.03E+05 FE-55 O.OOE+OO O.OOE+OO FE-59 2.73E+08 2.73E+08 CO-57 O.OOE+OO O.OOE+OO CO-58 3.79E+08 3.79E+08 CO-60 2.15E+10 2.15E+10 NI-63 O.OOE+OO O.OOE+OO NI-65 2.97E+05 2.97E+05 CU-64 6.07E+05 6.07E+05 ZN-65 7.47E+08 7.47E+08 ZN-69 O.OOE+OO O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO BR-83 4.87E+03 4.87E+03 BR-84 2.03E+05 2.03E+05 BR-85 O.OOE+OO O.OOE+OO RB-86 8.99E+06 8.99E+06 RB-88 3.31E+04 3.31E+04 RB-89 1.23E+05 1.23E+05 SR-89 2.16E+04 2.16E+04 SR-91 2.15E+06 2.15E+06 SR-92 7.77E+05 7.77E+05 Y-90 4.49E+03 4.49E+03 Y-91M 1.OOE+05 1.OOE+05 Y-91 1.07E+06 1.07E+06 Y-92 1.80E+05 1.80E+05 Y-93 1.83E+05 1.83E+05 ZR-95 2.45E+08 2.45E+08 ZR-97 2.96E+06 2.96E+06 NB-95 1.37E+08 1.37E+08 NB-97 O.OOE+OO O.OOE+OO MO-99 3.99E+06 3.99E+06 TC-99M 1.84E+05 1.84E+OS TC-101 2.04E+04 2.04E+04 RU-103 1.08E+08 1.08E+08 RU-105 6.36E+05 6.36E+05 RU-106 4.22E+08 4.22E+08 AG-ilOM 3.41E+09 3.41E+09 SB-124 O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO TE-125M 1.55E+06 1.55E+06 TE-127M 9.16E+04 9.16E+04 TE-127 2.98E+03 2.98E+03 TE-129M 1.98E+07 1.98E+07 TE-129 2.62E+04 2.62E+04 O.OOE+OO O.OOE+OO 1.19E+07 O.OOE+OO 4.66E+06 1.39E+09 9.03E+05 O.OOE+OO 2.73E+08 O.OOE+OO 3.79E+08 2.15E+10 O.OOE+OO 2.97E+05 6.07E+05 7.47E+08 O.OOE+OO O.OOE+OO O.OOE+OO 4.87E+03 2.03E+05 O.OOE+OO 8.99E+06 3.31E+04 1.23E+05 2.16E+04 2.15E+06 7.77E+05 4.49E+03 1.OOE+05 1.07E+06 1.80E+05 1.83E+05 2.45E+08 2.96E+06 1.37E+08 O.OOE+OO 3.99E+06 1.84E+05 2.04E+04 1.08E+08 6.36E+05 4.22E+08 3.41E+09 O.OOE+OO O.OOE+OO 1.55E+06 9.16E+04 2.98E+03 1.98E+07 2.62E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.19E+07 1.19E+07 1.19E+07 1.19E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.66E+06 4.66E+06 4.66E+06 4.66E+06 1.39E+09 1.39E+09 1.39E+09 1.39E+09 9.03E+05 9.03E+05 9.03E+05 9.03E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.73E+08 2.73E+08 2.73E+08 2.73E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.79E+08 3.79E+08 3.79E+08 3.79E+08 2.15E+10 2.15E+10 2.15E+10 2.15E+10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.97E+05 2.97E+05 2.97E+05 2.97E+05 6.07E+05 6.07E+05 6.07E+05 6.07E+05 7.47E+08 7.47E+08 7.47E+08 7.48E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.87E+03 4.87E+03 4.87E+03 4.87E+03 2.03E+05 2.03E+05 2.03E+05 2.03E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.99E+06 8.99E+06 8.99E+06 8.99E+06 3.31E+04 3.31E+04 3.31E+04 3.31E+04 1.23E+05 1.23E+05 1.23E+05 1.23E+05 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.15E+06 2.15E+06 2.15E+06 2.15E+06 7.77E+05 7.77E+05 7.77E+05 7.77E+05 4.49E+03 4.49E+03 4.49E+03 4.49E+03 1.OOE+05 1.OOE+05 1.OOE+05 1.OOE+05 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.96E+06 2.96E+06 2.96E+06 2.96E+06 1.37E+08 1.37E+08 1.37E+08 1.37E+08 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.99E+06 3.99E+06 3.99E+06 3.99E+06 1.84E+05 1.84E+05 1.84E+05 1.84E+05 2.04E+04 2.04E+04 2.04E+04 2.04E+04 1.08E+08 1.08E+08 1.08E+08 1.08E+08 6.36E+05 6.36E+05 6.36E+05 6.36E+05 4.22E+08 4.22E+08 4.22E+08 4.22E+08 3.41E+09 3.41E+09 3.41E+09 3.41E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.55E+06 1.55E+06 1.55E+06 1.S5E+06 9.16E+04 9.16E+04 9.16E+04 9.16E+04 2.98E+03 2.98E+03 2.98E+03 2.98E+03 1.98E+07 1.98E+07 1.98E+07 1.98E+07 2.62E+04 2.62E+04 2.62E+04 2.62E+04 O.OOE+OO O.OOE+OO 1.39E+07 O.OOE+OO 5.51E+06 1.62E+09 1.07E+06 O.OOE+OO 3.21E+08 O.OOE+OO 4.44E+08 2.53E+10 O.OOE+OO 3.45E+05 6.88E+05 8.59E+08 O.OOE+OO O.OOE+OO O.OOE+OO 7.08E+03 2.36E+05 O.OOE+OO 1.03E+07 3.78E+04 1.48E+05 2.51E+04 2.51E+06 8.63E+05 5.31E+03 1.16E+05 1.21E+06 2.14E+05 2.5 1E+05 2.84E+08 3.44E+06 1.61E+08 O.OOE+OO 4.63E+06 2.11E+05 2.26E+04 1.26E+08 7.21E+05 5.07E+08 5.88E+O9 l lD5 O.OOE+OO O.OOE+OO 2.13E+06 1.08E+05 3.28E+03 2.3 IE+07 3.10E+04 RSP-0008 REV - 13 PAGE 69 OF 104 RSP-0008

~

~

~

_E-3 PGE9FO

INFORMATION USE ATTACHMENT 19 PAGE 2 OF 2 TABLE 1-5: DOSE FACTOR TABLE: R (I) - ALL, GR PLANE Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 9.46E+06 TE-131 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 3.45E+07 TE-132 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.98E+06 I-130 5.51E+06 5.51E+06 5.51E+06 5.51E+06 5.51E+06 5.51E+06 5.51E+06 6.69E+06 1-131 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 2.09E+07 1-132 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.46E+06 1-133 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.98E+06 1-134 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 5.30E+05 1-135 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.95E+06 CS-134 6.86E+09 6.86E+09 6.86E+09 6.86E+09 6.86E+09 6.86E+09 6.86E+09 8.OOE+09 CS-136 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.71E+08 CS-137 1.03E+10 1.03E+10 1.03E+10 1.03E+10 1.03E+10 1.03E+10 1.03E+10 1.20E+10 CS-138 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 4.10E+05 BA-139 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.19E+05 BA-140 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.35E+07 BA-141 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.75E+04 BA-142 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 5.1 1E+04 LA.140 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 2.18E+07 LA-142 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 9.11E+05 CE-141 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.54E+07 CE-143 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.63E+06 CE-144 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 8.04E+07 PR-143 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 PR-144 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 2.1IE+03 ND-147 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 1.O1E+07 W-187 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.73E+06 NP-239 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.98E+06 RSP-0008 REV-13 PAGE 70 OF 104

INFORMATION USE ATTACHMENT 20 PAGE 1 OF 2 TABLE 1-6: DOSE FACTOR TABLE: R (I) - ADULT, COWS MILK TABLE 1-6 DOSE FACTOR TABLE: R (i) -Adult, cows' milk Units are m2*mrem/yr per pCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+00 C-14 3.63E+05 NA-24 2.44E+06 P-32 1.62E+10 CR-51 O.OOE+00 MN-54 O.OOE+00 MN-56 O.OOE+00 FE-55 1.95E+07 FE-59 2.55E+07 CO-57 O.OOE+00 CO-58 O.OOE+00 CO-60 O.OOE+00 NI-63 5.21E+09 NI-65 3.76E-01 CU-64 O.OOE+00 ZN-65 1.09E+09 ZN-69 2.18E-12 ZN-69M O.OOE+00 BR-82 O.OOE+00 BR-83 O.OOE+00 BR-84 O.OOE+00 BR-85 O.OOE+00 RB-86 O.OOE+00 RB-88 O.OOE+00 RB-89 O.OOE+00 SR-89 1.23E+09 SR-90 3.62E+10 SR-91 2.90E+04 SR-92 4.95E-01 Y-90 7.09E+01 Y-91M 6.27E-20 Y-91 7.22E+03 Y-92 5.64E-05 Y-93 2.24E-01 ZR-95 7.89E+02 ZR-97 4.34E-01 NB-95 7.22E+04 NB-97 O.OOE+00 MO-99 O.OOE+00 TC-99M 3.34E+00 TC-101 O.OOE+00 RU-103 8.82E+02 RU-105 8.64E-04 RU-106 1.60E+04 AG-l lOM 4.61E+07 SB-124 O.OOE+00 SB-125 O.OOE+00 TE-125M 1.37E+07 TE-127M 3.72E+07 TE-127 6.56E+02 TE-129M 5.29E+07 TE-129 2.92E-10 4.73E+02 7.26E+04 2.44E+06 1.O1E+09 O.OOE+00 6.63E+06 4.21E-03 1.35E+07 5.99E+07 O.OOE+00 3.92E+06 1.27E+07 3.61E+08 4.88E-02 2.39E+04 3.46E+09 4.17E-12 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2.40E+09 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2.53E+02 8.76E-02 4.02E+04 O.OOE+00 2.48E+07 9.44E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4.73E+02 4.73E+02 7.26E+04 7.26E+04 2.44E+06 2.44E+06 6.26E+08 O.OOE+00 2.55E+04 1.53E+04 1.27E+06 O.OOE+00 7.47E-04 O.OOE+00 3.15E+06 O.OOE+00 2.30E+07 O.OOE+00 O.OOE+00 O.OOE+00 8.78E+06 O.OOE+00 2.81E+07 O.OOE+00 1.75E+08 O.OOE+00 2.23E-02 O.OOE+00 1.12E+04 O.OOE+00 1.56E+09 O.OOE+00 2.90E-13 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 9.87E-02 O.OOE+00 1.73E-23 O.OOE+00 O.OOE+00 O.OOE+00 1.12E+09 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3.54E+07 O.OOE+00 8.89E+09 O.OOE+00 1.17E+03 O.OOE+00 2.14E-02 O.OOE+00 1.90E+00 O.OOE+00 2.43E-21 O.OOE+00 1.93E+02 O.OOE+00 1.65E-06 O.OOE+00 6.19E-03 O.OOE+00 1.71E+02 O.OOE+00 4.01E-02 O.OOE+00 2.16E+04 O.OOE+00 O.OOE+00 O.OOE+00 4.71E+06 O.OOE+00 1.20E+02 O.OOE+00 O.OOE+00 O.OOE+00 3.80E+02 O.OOE+00 3.41E-04 O.OOE+00 2.03E+03 O.OOE+00 4.73E+02 7.26E+04 2.44E+06 O.OOE+00 5.62E+03 1.97E+06 5.34E-03 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6.03E+04 2.3 lE+09 2.71E-12 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3.97E+02 1.32E-01 3.97E+04 O.OOE+00 5.61E+07 1.43E+02 O.OOE+00 3.37E+03 1.12E-02 3.10E+04 8.38E+07 O.OOE+00 O.OOE+OO 5.58E+07 4.73E+02 7.26E+04 2.44E+06 O.OOE+OO 3.39E+04 O.OOE+OO O.OOE+OO 7.53E+06 1.67E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.63E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.73E+02 7.26E+04 2.44E+06 1.82E+09 6.42E+06 2.03E+07 1.34E-O1 7.75E+06 2.OOE+08 O.OOE+OO 7.94E+07 2.39E+08 7.53E+07 1.24E+OO 2.04E+06 2.18E+09 6.26E-13 O.OOE+OO O.OOE+OO 1.42E-O1 1.36E-28 O.OOE+OO 4.74E+08 O.OOE+OO O.OOE+OO 1.98E+08 1.05E+09 1.38E+05 9.81E+OO 7.51E+05 1.84E-19 3.98E+06 9.88E-O1 7.1 1E+03 8.02E+05 2.71E+04 2.44E+08 O.OOE+OO 5.74E+07 5.59E+03 O.OOE+OO 1.03E+05 5.29E-O1 1.04E+06 1.74E+10 O.OOE+OO O.OOE+OO 5.48E+07 1.25E+08 5.17E+04 2.66E+08 2.20E-10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.26E+07 2.53E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.97E+06 1.84E+06 4.12E+06 1.33E+07 4.53E+06 9.51E+06 2.35E+02 1.42E+02 4.86E+02 1.97E+07 8.37E+06 1.82E+07 1.1OE-10 7.11E-11 2.24E-10 1.51E+08 O.OOE+OO 2.67E+03 O.OOE+OO 2.21E+08 O.OOE+OO 1.23E-09 O.OOE+OO RSP-0008 REV-13 PAGE 71 OF 104

INFORMATION USE ATTACHMENT 20 PAGE 2 OF 2 TABLE 1-6: DOSE FACTOR TABLE: R (I) - ADULT, COWS MLK Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 3.62E+05 TE-131 3.95E-33 TE-132 2.40E+06 1-130 4.21E+05 1-131 2.91E+08 1-132 1.67E-O1 I-133 3.88E+06 1-134 2.11E-12 I-135 1.29E+04 CS-134 4.41E+09 CS-136 2.51E+08 CS-137 5.71E+09 CS-138 9.72E-24 BA-139 4.54E-08 BA-140 2.57E+07 BA-141 O.OOE+00 BA-142 O.OOE+00 LA-140 4.52E+00 LA-142 1.90E-1 I CE-141 4.27E+03 CE-143 4.16E+01 CE-144 2.82E+05 PR-143 1.50E+02 PR-144 O.OOE+O0 ND-147 9.10E+01 W-187 6.52E+03 NP-239 3.67E+00 1.77E+05 1.65E-33 1.55E+06 1.24E+06 4.16E+08 4.47E-01 6.74E+02 5.72E-12 3.38E+04 1.05E+10 9.91E+08 7.81E+09 1.92E-23 3.24E-11 3.23E+04 O.OOE+00 O.OOE+00 2.28E+00 8.66E-12 2.89E+03 3.08E+04 1.18E+05 6.02E+01 0.OOE+00 1.05E+02 5.45E+03 3.61E-01 1.47E+05 2.80E+05 1.79E+06 1.25E-33 3.25E-33 1.73E-32 1.46E+06 1.72E+06 1.50E+07 4.90E+05 1.05E+08 1.94E+06 2.38E+08 1.36E+11 7.13E+08 1.56E-01 1.56E+01 7.12E-01 2.06E+06 9.91E+08 1.18E+07 2.05E-12 9.92E-11 9.10E-12 1.25E+04 2.23E+06 5.42E+04 8.57E+09 O.OOE+00 3.39E+09 7.13E+08 O.OOE+00 5.51E+08 5.12E+09 O.OOE+00 2.65E+09 9.50E-24 O.OOE+00 1.41E-23 1.33E-09 O.OOE+00 3.03E-1 I 1.68E+06 O.OOE+00 1.1OE+04 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O 0.OOE+O0 6.01E-01 O.OOE+00 O.OOE+00 2.16E-12 O.OOE+00 O.OOE+00 3.27E+02 O.OOE+00 1.34E+03 3.40E+00 O.OOE+00 1.35E+00 1.52E+04 O.OOE+00 7.OOE+04 7.44E+00 O.OOE+00 3.48E+01 O.OOE+00 O.OOE+0O O.OOE+O0 6.29E+00 O.OOE+OO 6.15E+01 1.90E+03 O.OOE+00 0.OOE+00 1.99E-01 0.OOE+00 1.13E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00

1. 131E+09 7.56E+07 8.82E+08 1.39E-24 1.84E-1 1 1.85E+04 0.OO3+O00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1.76E+07 5.60E-34 7.35E+07 1.07E+06 1.1OE+08 8.39E-02 6.06E+06 4.99E-15 3.82E+04 1.84E+08 1.13E+08 1.51E+08 8.18E-29 8.06E-08 5.29E+07 O.OOE+0O O.OOE+00 1.67E+05 6.32E-08 1.1OE+07
1. 15E+06 9.55E+07 6.58E+05 0.OOE+O0 5.05E+05 1.78E+06 7.41E+04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE3+00 0.OOE+00 0.OOE+O0 0.OOE+O0 0.OOE+00 0.OOE1+00 0.OOE+00 O.OOE+O0 0.OOE+O0 O.OOE+O0 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 RSP-0008 REV-13 PAGE 72 OF 104

INFORMATION USE ATTACHMENT 21 PAGE I OF 2 TABLE 1-7: DOSE FACTOR TABLE: R (I) - TEEN, COWS MILK TABLE 1-7 DOSE FACTOR TABLE: R (i) - Teen, cows'milk Units are m2*mrem/yr per pLCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 6.16E+02 6.16E+02 6.16E+02 6.16E+02 6.16E+02 C-14 6.70E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 NA-24 4.27E+06 4.27E+06 4.27E+06 4.27E+06 4.27E+06 4.27E+06 P-32 2.99E+10 1.85E+09 1.16E+09 O.OOE+OO O.OOE+OO O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 4.46E+04 2.48E+04 9.77E+03 6.36E+04 MN-54 O.OOE+OO 1.lOE+07 2.19E+06 O.OOE+OO 3.30E+06 O.OOE+OO MN-56 O.OOE+OO 7.46E-03 1.33E-03 O.OOE+OO 9.45E-03 O.OOE+OO FE-55 3.47E+07 2.46E+07 5.73E+06 O.OOE+OO O.OOE+OO 1.56E+07 FE-59 4.45E+07 1.04E+08 4.01E+07 O.OOE+OO O.OOE+OO 3.27E+07 CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 6.60E+06 1.52E+07 O.OOE+OO O.OOE+OO O.OOE+OO CO-60 O.OOE+OO 2.16E+07 4.86E+07 O.OOE+OO O.OOE+OO O.OOE+OO NI-63 9.15E+09 6.46E+08 3.10E+08 O.OOE+OO O.OOE+OO O.OOE+OO NI-65 6.87E-01 8.78E-02 4.OOE-02 O.OOE+OO O.OOE+OO O.OOE+OO CU-64 O.OOE+OO 4.26E+04 2.OOE+04 O.OOE+OO 1.08E+05 O.OOE+OO ZN-65 1.67E+09 5.79E+09 2.70E+09 O.OOE+OO 3.71E+09 O.OOE+OO ZN-69 4.01E-12 7.65E-12 5.35E-13 O.OOE+OO 5.OOE-12 O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 1.82E-O1 O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 3.09E-23 O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 4.38E+09 2.06E+09 O.OOE+OO O.OOE+OO O.OOE+OO RB-88 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-89 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SR-89 2.27E+09 O.OOE+OO 6.51E+07 O.OOE+OO O.OOE+OO O.OOE+OO SR-90 5.12E+10 O.OOE+OO 1.26E+10 O.OOE+OO O.OOE+OO O.OOE+OO SR-91 5.33E+04 O.OOE+OO 2.12E+03 O.OOE+OO O.OOE+OO O.OOE+OO SR-92 9.07E-O1 O.OOE+OO 3.86E-02 O.OOE+OO O.OOE+OO O.OOE+OO Y-90 1.30E+02 O.OOE+OO 3.51E+OO O.OOE+OO O.OOE+OO O.OOE+OO Y-91M 1.15E-19 O.OOE+OO 4.39E-21 O.OOE+OO O.OOE+OO O.OOE+OO Y-91 1.33E+04 O.OOE+OO 3.56E+02 O.OOE+OO O.OOE+OO O.OOE+OO Y-92 1.04E-04 O.OOE+OO 3.01E-06 O.OOE+OO O.OOE+OO O.OOE+OO Y-93 4.13E-O1 O.OOE+OO 1.13E-02 O.OOE+OO O.OOE+OO O.OOE+OO ZR-95 1.38E+03 4.35E+02 2.99E+02 O.OOE+OO 6.40E+02 O.OOE+OO ZR-97 7.90E-01 1.56E-01 7.20E-02 O.OOE+00 2.37E-01 O.OOE+00 NB-95 1.23E+05 6.83E+04 3.76E+04 O.OOE+OO 6.62E+04 O.OOE+OO NB-97

-O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO MO-99 O.OOE+OO 4.47E+07 8.53E+06 O.OOE+OO 1.02E+08 O.OOE+OO TC-99M 5.80E+00 1.62E+01 2.10E+02 O.OOE+OO 2.41E+02 8.97E+OO TC-101 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RU-103 1.57E+03 O.OOE+OO 6.71E+02 O.OOE+OO 5.53E+03 O.OOE+OO RU-105 1.58E-03 O.OOE+OO 6.13E-04 O.OOE+OO l.99E-02 O.OOE+OO RU-106 2.95E+04 O.OOE+OO 3.72E+03 O.OOE+OO 5.69E+04 O.OOE+OO AG-llOM 7.62E+07 7.21E+07 4.39E+07 O.OOE+OO 1.38E+08 O.OOE+OO SB-124 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 2.53E+07 9.1 1E+06 3.38E+06 7.06E+06 O.OOE+OO O.OOE+OO TE-127M 6.86E+07 2.43E+07 8.16E+06 1.63E+07 2.78E+08 O.OOE+OO TE-127 1.22E+03 4.31E+02 2.61E+02 8.38E+02 4.92E+03 O.OOE+OO TE-129M 9.67E+07 3.59E+07 1.S3E+07 3.12E+07 4.04E+08 O.OOE+OO TE-129 5.37E-10 2.OOE-10 1.31E-10 3.84E-10 2.25E-09 O.OOE+OO 6.16E+02 1.34E+05 4.27E+06 2.51E+09 7.49E+06 2.27E+07 4.911E-01 1.06E+07 2.45E+08 O.OOE+00 9.09E+07 2.81E+08 1.03E+08 4.76E+OO 3.30E+06 2.45E+09 1.41E-1 1 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6.48E+08 O.OOE+00 O.OOE+00 2.71E+08 1.44E+09 2.42E+05 2.31E+01 1.07E+06 5.42E-18 5.45E+06 2.86E+00 1.26E+04 1.OOE+06 4.23E+04 2.92E+08 O.OOE+00 8.01E+07 1.06E+04 O.OOE+00 1.31E+05 1.27E+00 1.41E+06 2.03E+10 O.OOE+00 O.OOE+00 7.46E+07 1.71E+08 9.38E+04 3.63E+08 2.94E-09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO

.O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RSP-0008 REV-13 PAGE 73 OF 104

INFORMATION USE ATTACHMENT 21 PAGE2 OF2 TABLE I-7: DOSE FACTOR TABLE: R (I) - TEEN, COWS MILK Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 6.58E+05 3.15E+05 2.63E+05 4.75E+05 3.29E+06 O.OOE+00 2.53E+07 O.OOE+O0 TE-131 7.22E-33 2.98E-33 2.26E-33 5.57E-33 3.16E-32 O.OOE+00 5.93E-34 O.OOE+00 TE-132 4.29E+06 2.72E+06 2.56E+06 2.87E+06 2.61E+07 O.OOE+00 8.61E+07 O.OOE+00 I-130 7.41E+05 2.14E+06 8.56E+05 1.75E+08 3.30E+06 O.OOE+00 1.65E+06 O.OOE+00 1-131 5.28E+08 7.39E+08 3.97E+08 2.16E+1 1 1.27E+09 O.OOE+00 1.46E+08 O.OOE+00 I-132 2.96E-01 7.75E-01 2.78E-01 2.61E+01 1.22E+0O O.OOE+O0 3.38E-01 O.OOE+00 I-133 7.08E+06 1.20E+07 3.66E+06 1.68E+09 2.11E+07 O.OOE+00 9.09E+06 O.OOE+0O 1-134 3.74E-12 9.92E-12 3.56E-12 1.65E-10 1.56E-11 O.OOE+00 1.31E-13 O.OOE+00 I-135 2.29E+04 5.90E+04 2.19E+04 3.80E+06 9.33E+04 O.OOE+00 6.54E+04 O.OOE+O0 CS-134 7.65E+09 1.80E+10 8.36E+09 O.OOE+00 5.72E+09 2.19E+09 2.24E+08 O.OOE+00 CS-136 4.27E+08 1.68E+09 1.13E+09 O.OOE+00 9.15E+08 1.44E+08 1.35E+08 O.OOE+O0 CS-137 1.04E+10 1.38E+10 4.80E+09 O.OOE+00 4.69E+09 1.82E+09 1.96E+08 O.OOE+00 CS-138 1.76E-23 3.38E-23 1.69E-23 O.OOE+00 2.50E-23 2.91E-24 1.54E-26 O.OOE+00 BA-139 8.40E-08 5.91E-11 2.45E-09 O.OOE+00 5.57E-11 4.07E-11 7.50E-07 O.OOE+00 BA-140 4.64E+07 5.68E+04 2.99E+06 O.OOE+O0 1.93E+04 3.82E+04 7.15E+07 O.OOE+00 BA-141 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 BA-142 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LA-140 8.11E+00 3.98E+00 1.06E+0O O.OOE+00 O.OOE+00 O.OOE+00 2.29E+05 O.OOE+O0 LA-142 3.43E-1 1 1.53E-11 3.80E-12 O.OOE+00 O.OOE+00 O.OOE+00 4.64E-07 O.OOE+00 CE-141 7.82E+03 5.22E+03 6.OOE+02 O.OOE+00 2.46E+03 O.OOE+00 1.49E+07 O.OOE+O0 CE-143 7.65E+01 5.56E+04 6.21E+00 O.OOE+00 2.50E+I01 O.OOE+00 1.67E+06 O.OOE+00 CE-144 5.20E+05 2.15E+05 2.79E+04 O.OOE+00 1.28E+05 O.OOE+00 1.31E+08 O.OOE+00 PR-143 2.76E+02 1.10E+02 1.37E+O1 O.OOE+00 6.40E+01 O.OOE+00 9.08E+05 O.OOE+O0 PR-144 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 ND-147 1.75E+02 1.90E+02 1.14E+01 O.OOE+00 1.12E+02 O.OOE+00 6.87E+05 O.OOE+00 W-187 1.19E+04 9.71E+03 3.40E+03 O.OOE+00 O.OOE+O0 O.OOE+00 2.63E+06 O.OOE+OO NP-239 7.01E+00 6.61E-01 3.67E-01 O.OOE+00 2.08E+00 O.OOE+00 1.06E+05 0.OOE+00 RSP-0008 REV-13 PAGE 74 OF 104

101110001mm INFORMATION USE ATTACHMENT 22 PAGE 1 OF 2 TABLE I-8: DOSE FACTOR TABLE R (1) - CHILD, COWS MILK TABLE I-8 DOSE FACTOR TABLE: R (i) - Child, cows' milk Units are m2*mrem/yr per piCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 ZN-69M BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91M Y-91 Y-92 Y-93 ZR-95 ZR-97 NB-95 0.OOE+00 1.651E+06 8.88E3+06 7.37E+10 0.OOE3+00 0.OO3+O00 0.OOE+00 8.701E+07 1.03E+08 O.OOE+00 0.OOE3+00 0.OO3+O00 2.291E+10 1.68E+00 0.OOE3+00 3.27E3+09 9.87E3-12 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OO3+O00 5.63E3+09 8.651E+10 1.3 1E+05 2.21E+00 3.221E+02 2.801E-19 3.281E+04 2.561E-04 1.02E+00 3.20E+03 1.92E3+00 2.78E+05 9.73E+02 3.29E+05 8.88E+06 3.45E+09 0.OOE+00 1.65E1+07 1.30E3-02 4.61E+07 1.67E+08 O.OO1+O00 1.0 1E+07 3.35E1+07 1.23E+09 1.58E-01 7.48E+04 8.72E3+09 1.43E3-1 1 0.OOE+O0 0.OOE3+00 0.OOE1+00 0.OOE3+00 0.OOE1+00 8.121E+09 0.OO1+O00 0.OOE3+00 0.OOE+00 0.OO1+O00 0.O0E+00 0.OO3+O00 0.OOE+00 0.OOE1+00 0.OOE+O0 0.OOE1+00 0.OOE+00 7.04E1+02 2.78E-01 1.08E3+05 9.73E3+02 3.29E+05 8.88E+06 2.84E+09 9.091E+04 4.40E+06 2.941E-03 1.431E+07 8.31E+07 O.OOE+00 3.08E+07 9.881E+07 7.801E+08 9.241E-02 4.521E+04 5.43E+09 1.32E-12 0.OOE+00 0.OOE+00 4.47E1-01 7.001E-23 O.OOE+00 4.991E+09 0.OOE+00 0.OOE1+00 1.61E+08 2.191E+10 4.94E1+03 8.881E-02 8.63E+00 1.02E1-20 8.78E1+02 7.32E-06 2.791E-02 6.27E+02 1.64E-01 7.74E+04 O.OOE+00 9.73E+02 3.291E+05 8.881E+06 0.OOE+00 5.05E+04 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 O.OOE3+00 0.OOE3+00 0.OOE3+00 0.OO3+O00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OO3+O00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OO3+O00 0.OOE3+00 0.OOE3+00 0.OOE1+00 O.OOE+00 0.OOE3+00 0.OOE1+00 0.OOE3+00 0.OOE3+00 0.OOE+00 9.731E+02 3.291E+05 8.881E+06 0.OOE+00 1.381E+04 4.631E+00 1.57E-02 0.OOE1+00 0.OOE1+00 0.OOE1+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE+00 1.811E+05 5.501E+09 8.65E-12 0.OO1+O00 0.OO1+O00 O.OOE+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE1+00 0.OOE1+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 1.O1E+03 3.99E-01 1.02E1+05 0.OOE3+00 9.73E3+02 3.291E+05 8.88E3+06 0.OOE1+00 9.21E+04 0.OOE+00 0.OOE1+00 2.611E+07 4.841E+07 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE1+00 0.OOE1+00 0.OOE+00 0.OOE1+00 0.OO3+O00 0.OOE3+00 0.OOE1+00 0.OOE+00 0.OOE1+00 0.OOE+O00 0.OOE+00 1.32E1+01 0.OOE1+00 0.OOE1+00 0.OOE3+00 0.OOE3+00 0.OOE1+00 0.OOE1+00 0.OOE3+00 9.73E+02 3.29E+05 8.88E+06 2.04E+09 4.821E+06 1.39E+07 1.891E+00 8.55E+06 1.741E+08 0.OOE+00 5.88E+07 1.86E+08 8.27E+07 1.94E+01 3.5 1E+06 1.53E+09 8.99E-10 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 5.22E+08 0.OOE+00 0.OOE+00 2.18E+08 1.16E+09 2.89E+05 4.19E+01 9.18E+05 5.49E-16 4.37E+06 7.39E+00 1.5 1E+04 7.35E+05 4.21E+04 2.OOE+08 0.OO1+O00 6.731E+07 1.48E+04 0.OOE+00 9.59E+04 2.5 1E+00 1.13E+06 1.33E1+10 0.OOE1+00 0.OOE+00 0.OOE1+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE3+00 0.OOE1+00 0.OOE3+00 0.OOE+O0 0.OOE+00 0.OO1+O00 0.OOE3+00 0.OOE+00 0.OOE3+00 0.OOE1+00 0.OOE3+00 0.OOE1+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE3+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE11-00 0.OOE3+00 0.OOE3+00 0.OOE1+00 0.OOE1+00 0.OO1+O00 0.OO3+O00 0.OOE1+00 0.OOE+O0 0.OOE+O0 0.OOE1+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE3+00 O.OOE+00 0.OOE3+00 NB-97 0.OOE3+00 0.OOE3+00 MO-99 O.OOE+0O 8.14E+07 2.01E+07 0.OOE+00 1.74E+08 TC-99M 1.33E+01 2.61E+01 4.32E+02 0.OOE+00 3.79E+02 TC-I01 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 RU-103 3.71E+03 O.OOE+00 1.43E+03 O.OOE+00 9.34E+03 RU-105 3.85E-03 0.OOE+00 1.40E-03 0.OOE+00 3.39E-02 RU-106 7.26E+04 0.OOE+00 9.06E+03 0.OOE+00 9.81E+04 AG-IIOM 1.65E+08 1.12E+08 8.92E+07 0.OOE+00 2.08E+08 SB-124 0.OOE+00 O.OOE+O0 0.OOE+00 O.OOE+00 O.OOE+00 SB-125 0.OOE+00 0.OOE+00 0.OOE+0O 0.OOE+00 0.OOE+00 TE-125M 6.21E+07 1.68E+07 8.28E+06 1.74E+07 O.OOE+00 TE-127M 1.69E+08 4.55E+07 2.01E+07 4.04E+07 4.82E+08 0.OOE1+00 5.99E+07 0.OOE+00 1.3711+08 TE-127 2.99E+03 8.06E+02 6.41E+02 2.07E+03 8.SOE+03 0.OOE+00 1.17E+05 TE-129M 2.38E+08 6.65E+07 3.70E+07 1.68E+07 7.00E+08 0.OOE+0O 2.91E+08 TE-129 1.33E-09 3.70E-IQ 3.15E-10 9.46E-10 3.88E-09 0.OOE+0O 8.25E-08 RSP-0008 REV-13 PAGE 75 OF 104

INFORMATION USE ATTACHMENT 22 PAGE 2 OF 2 TABLE I-8: DOSE FACTOR TABLE R (I) - CHILD, COWS MILK Nuclide Bone Liver Tbody Thyroid Kidney Lune GI Tract Skin TE-131M 1.60E+06 TE-131 1.77E-32 TE-132 1.02E+07 1-130 1.73E+06 1-131 1.28E+09 1-132 7.01E-01 I-133 1.72E+07 1-134 8.87E-12 1-135 5.43E+04 CS-134 1.77E+10 CS-136 9.65E+08 CS-137 2.50E+10 CS-138 4.27E-23 BA-139 2.06E-07 BA-140 1.12E+08 BA-141 O.OOE+00 BA-142 O.OOE+00 LA-140 1.94E+01 LA-142 8.30E-11 CE-141 1.93E+04 CE-143 1.88E+02 CE-144 1.28E+06 PR-143 6.83E+02 PR-144 O.OOE+00 ND-147 4.29E+02 W-187 2.89E+04 NP-239 1.73E+01 5.54E+05 5.89E+05 5.40E-33 5.27E-33 4.54E+06 5.48E+06 3.50E+06 1.80E+06 1.29E+09 7.32E+08 1.29E+00 5.92E-01 2.13E+07 8.05E+06 1.65E-11 7.57E-12 9.77E+04 4.62E+04 2.90E+10 6.11E+09 2.65E+09 1.72E+09 2.39E+10 3.53E+09 5.94E-23 3.77E-23 1.IOE-10 5.98E-09 9.80E+04 6.53E+06 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6.79E+00 2.29E+00 2.64E-11 8.28E-12 9.61E+03 1.43E+03 1.02E+05 1.47E+01 4.02E+05 6.84E+04 2.05E+02 3.39E+01 O.OOE+00 O.OOE+00 3.48E+02 2.69E+01 1.71E+04 7.68E+03 1.24E+00 8.71E-01 1.14E+06 1.36E-32 6.61E+06 3.86E+08 4.26E+1 1 5.97E+01 3.95E+09 3.79E-10 8.66E+06 O.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+O0 0.OOE+00 5.36E+06 5.36E-32 4.21E+07 5.23E+06 2.1 IE+09 1.97E+00 3.55E+07 2.52E-I I 1.50E+05 8.98E+09 1.41E+09 7.78E+09 4.18E-23 9.62E-I I 3.19E+04 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4.21E+03 4.27E+01 2.22E+05

1. I IE+02 O.OOE+00 1.91E+02 O.OOE+00 3.58E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.22E+09 2.1 IE+08 2.80E+09 4.50E-24 6.48E-1 1 5.84E+04 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 2.25E+07 9.3 1E-32 4.57E+07 1.64E+06
1. 15E+08 1.52E+00 8.57E+06 1.09E-11 7.45E+04 1.56E+08 9.32E+07 1.50E+08 2.74E-23 1.19E-05 5.67E+07 0.OOE+00 0.OOE+00 1.89E+05 5.24E-06 1.20E+07 1.49E+06 1.05E+08 7.37E+05 0.OOE+00 5.5 1E+05 2.40E+06 9.17E+04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+O0 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0,OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 O.OOE+O0 0.OOE+O0 O.OOE+00 0.OOE+O0 0.OOE+O0 O.OOE+00 O.OOE+00 0.OOE+00 RSP-0008 REV-13 PAGE 76 OF 104

INFORMATION USE ATTACHMENT 23 PAGE 1 OF 2 TABLE 1-9: DOSE FACTOR TABLE: R (I) - INFANT, COWS MILK TABLE I-9 DOSE FACTOR TABLE: R (i) - Infant, cows' milk Units are m2*mrem/yr per iCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 1.48E+03 1.48E+03 1.48E+03 1.48E+03 1.48E+03 1.48E+03 O.OOE+OO C-14 3.23E+06 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 6.89E+05 O.OOE+OO NA-24 1.55E+07 1.55E+07 1.55E+07 1.55E+07 1.55E+07 1.5SE+07 1.55E+07 O.OOE+OO P-32 1.52E+11 8.93E+09 5.88E+09 O.OOE+OO O.OOE+OO O.OOE+OO 2.05E+09 O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 1.44E+05 9.40E+04 2.05E+04 1.83E+05 4.20E+06 O.OOE+OO MN-54 O.OOE+OO 3.07E+07 6.97E+06 O.OOE+OO 6.81E+06 O.OOE+OO 1.13E+07 O.OOE+OO MN-56 O.OOE+OO 3.19E-02 5.49E-03 O.OOE+OO 2.74E-02 O.OOE+OO 2.90E+OO O.OOE+OO FE-55 1.05E+08 6.79E+07 1.82E+07 O.OOE+OO O.OOE+OO 3.32E+07 8.62E+06 O.OOE+OO FE-59 1.92E+08 3.36E+08 1.32E+08 O.OOE+OO O.OOE+OO 9.94E+07 1.61E+08 O.OOE+OO CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 2.02E+07 5.03E+07 O.OOE+OO O.OOE+OO O.OOE+OO 5.02E+07 O.OOE+OO C0-60 O.OOE+OO 6.84E+07 1.62E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.63E+08 O.OOE+OO NI-63 2.70E+10 1.67E+09 9.38E+08 O.OOE+OO O.OOE+OO O.OOE+OO 8.31E+07 O.OOE+OO NI-65 3.56E+00 4.03E-01 1.83E-O1 O.OOE+OO O.OOE+OO O.OOE+OO 3.07E+O1 O.OOE+OO CU-64 O.OOE+OO 1.86E+05 8.61E+04 O.OOE+OO 3.15E+05 O.OOE+OO 3.82E+06 O.OOE+OO ZN-65 4.40E+09 1.51E+10 6.95E+09 O.OOE+OO 7.31E+09 O.OOE+OO 1.27E+10 O.OOE+OO ZN-69 2.10E-11 3.79E-11 2.82E-12 O.OOE+OO 1.57E-1 I O.OOE+OO 3.09E-09 O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 9.49E-O1 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 1.35E-22 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 2.06E+10 1.02E+10 O.OOE+OO O.OOE+OO O.OOE+OO 5.27E+08 O.OOE+OO RB-88 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-89 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SR-89 1.07E+10 O.OOE+OO 3.07E+08 O.OOE+OO O.OOE+OO O.OOE+OO 2.20E+08 O.OOE+OO SR-90 9.41E+10 O.OOE+OO 2.40E+10 O.OOE+OO O.OOE+OO O.OOE+OO 1.18E+09 O.OOE+OO SR-91 2.73E+05 O.OOE+OO 9.87E+03 O.OOE+OO O.OOE+OO O.OOE+OO 3.23E+05 O.OOE+OO SR-92 4.71E+OO O.OOE+OO 1.75E-O1 O.OOE+OO O.OOE+OO O.OOE+OO 5.08E+O1 O.OOE+OO Y-90 6.82E+02 O.OOE+OO 1.83E+O1 O.OOE+OO O.OOE+OO O.OOE+OO 9.41E+05 O.OOE+OO Y-91M 5.94E-19 O.OOE+OO 2.03E-20 O.OOE+OO O.OOE+OO O.OOE+OO 1.98E-15 O.OOE+OO Y-91 6.16E+04 O.OOE+OO 1.64E+03 O.OOE+OO O.OOE+OO O.OOE+OO 4.42E+06 O.OOE+OO Y-92 5.44E-04 O.OOE+OO 1.53E-05 O.OOE+OO O.OOE+OO O.OOE+OO 1.04E+O1 O.OOE+OO Y-93 2.16E+OO O.OOE+OO 5.90E-02 O.OOE+OO O.OOE+OO O.OOE+OO 1.71E+04 O.OOE+OO ZR-95 5.69E+03 1.39E+03 9.83E+02 O.OOE+OO 1.49E+03 O.OOE+OO 6.91E+05 O.OOE+OO ZR-97 4.07E+00 6.99E-01 3.19E-01 O.OOE+00 7.04E-01 O.OOE+00 4.46E+04 O.OOE+00 NB-95 5.19E+05 2.14E+05 1.24E+05 O.OOE+OO 1.53E+05 O.OOE+OO 1.80E+08 O.OOE+OO NB-97 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+00 MO-99 O.OOE+OO 2.08E+08 4.06E+07 O.OOE+OO 3.11E+08 O.OOE+OO 6.85E+07 O.OOE+OO TC-99M 2.77E+01 5.70E+01 7.35E+02 O.OOE+OO 6.14E+02 2.98E+0l 1.66E+04 O.OOE+OO TC-1O1 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RU-103 7.51E+03 O.OOE+OO 2.51E+03 O.OOE+OO 1.56E+04 O.OOE+OO 9.14E+04 O.OOE+OO RU-105 8.12E-03 O.OOE+OO 2.74E-03 O.OOE+OO 5.97E-02 O.OOE+OO 3.23E+OO O.OOE+OO RU-106 1.50E+05 O.OOE+OO 1.87E+04 O.OOE+OO 1.77E+05 OiOOE+OO 1.14E+06 O.OOE+OO AG-11OM 3.05E+08 2.23E+08 1.48E+08 O.OOE+OO 3.19E+08 O.OOE+OO 1.16E+10 O.OOE+OO SB-124 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 1.27E+08 4.24E+07 1.72E+07 4.27E+07 O.OOE+OO O.OOE+OO 6.05E+07 O.OOE+OO TE-127M 3.42E+08 1.14E+08 4.14E+07 9.89E+07 8.43E+08 O.OOE+OO 1.38E+08 O.OOE+OO TE-127 6.34E+03 2.13E+03 1.36E+03 5.16E+03 1.55E+04 O.OOE+OO 1.33E+05 O.OOE+OO TE-129M 4.89E+08 1.68E+08 7.54E+07 1.88E+08 1.22E+09 O.OOE+OO 2.92E+08 O.OOE+OO TE-129 2.81E.09 9.69E-10 6.56E-10 2.36E-09 7.OOE-09 O.OOE+OO 2.25E-07 O.OOE+OO RSP-0008 REV-13 PAGE 77 OF 104

INFORMATION USE ATTACHMENT 23 PAGE 2 OF 2 TABLE 1-9: DOSE FACTOR TABLE: R (1) - INFANT, COWS MILK Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M TE-131 TE-132 1-130 I-131 I-132 1-133 1-134 1-135 CS-134 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 W-187 NP-239 3.38E+06 3.76E-32 2.11E+07 3.56E+06 2.67E+09 1.45E+00 3.63E+07 1.84E-11 1.13E+05 2.84E+10 1.88E+09 3.98E+10 9.01E-23 4.39E-07 2.30E+08 O.OOE+00 O.OOE+00 4.06E+01 1.74E-10 3.82E+04 3.97E+02 1.84E+06 1.41E+03 O.OOE+00 8.51E+02 6.08E+04 3.65E+01 1.36E+06 1.39E-32 1.05E+07 7.83E+06 3.15E+09 2.95E+00 5.29E+07 3.77E-1 I 2.25E+05 5.30E+10 5.54E+09 4.66E+10 1.47E-22 2.91E-10 2.30E+05 O.OOE+00 O.OOE+00 1.60E+01 6.40E-1 1 2.33E+04 2.64E+05 7.52E+05 2.28E+02 O.OOE+00 8.74E+02 4.23E+04 3.26E+00 1.12E+06 1.05E-32 9.75E+06 3.14E+06 1.38E+09 1.05E+00 1.55E+07 1.34E-1 I 8.19E+04 5.36E+09 2.07E+09 3.30E+09

7. 10E-23 1.27E-08 1.19E+07 O.OOE+00 O.OOE+00 4.1 1E+00 1.53E-1 1 2.74E+03 3.01E+01 1.03E+05 7.OOE+01 O.OOE+00 5.36E+01 1.46E+04 1.84E+00 2.76E+06 3.35E-32 1.54E+07 8.781E+08 1.03E+12 1.38E+02 9.62E+09 8.78E-10 2.01E+07 0.OOE+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 9.37E+06 9.61E-32 6.53E+07 8.60E+06 3.68E+09 3.29E+00 6.22E+07 4.21E-11 2.50E+05 1.37E+10 2.21E+09 1.25E+10 7.31E-23 1.75E-10 5.47E+04 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 7.18E+03 7.68E+01 3.04E+05 1.96E+02 O.OOE+00 3.37E+02 O.OOE+00 6.51E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 5.60E+09 4.51E+08 5.07E+09 1.14E-23 1.77E-10 1.41E+05 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE3+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 2.29E+07 1.52E-30 3.87E+07 1.68E+06 1.12E+08 2.39E+00 8.95E+06 3.89E-1 I 8.13E+04 1.44E+08 8.41E+07 1.46E+08 2.34E-22 2.78E-05 5.66E+07 O.OOE+00 O.OOE+00 1.88E+05 1.09E-05 1.20E+07 1.54E+06 1.05E+08 7.45E+05 O.OOE+00 5.54E+05 2.49E+06 9.43E+04 0.OOE+O0 0.OOE+00 0.OOE+O0 O.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OO1+O00 0.OOE+00 0.OOE+00 0.OOE+00 RSP-0008 REV-13 PAGE 78 OF 104

INFORMATION USE ATTACHMENT 24 PAGE 1 0F2 TABLE I-10: DOSE FACTOR TABLE: R (I) - ADULT, GOATS MILK TABLE 1-10 DOSE FACTOR TABLE: R (i) - Adult, goats' milk Units are m2*mrem/yr per gjCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 9.65E+02 9.65E+02 9.65E+02 9.65E+02 9.65E+02 9.65E+02 O.OOE+OO C-14 3.63E+05 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 7.26E+04 O.OOE+OO NA-24 2.93E+05 2.93E+05 2.93E+05 2.93E+05 2.93E+05 2.93E+05 2.93E+05 O.OOE+OO P-32 1.94E+10 1.21E+09 7.51E+08 O.OOE+OO O.OOE+OO O.OOE+OO 2.18E+09 O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 3.06E+03 1.83E+03 6.75E+02 4.06E+03 7.70E+05 O.OOE+OO MN-54 O.OOE+OO 7.96E+05 1.52E+05 O.OOE+OO 2.37E+05 O.OOE+OO 2.44E+06 O.OOE+OO MN-56 O.OOE+OO 5.05E-04 8.96E-05 O.OOE+OO 6.41E-04 O.OOE+OO 1.61E-02 O.OOE+OO FE-55 2.54E+05 1.76E+05 4.09E+04 O.OOE+OO O.OOE+OO 9.79E+04 1.O1E+05 O.OOE+OO FE-59 3.31E+05 7.79E+05 2.98E+05 O.OOE+OO O.OOE+OO 2.18E+05 2.60E+06 O.OOE+OO CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 4.70E+05 1.05E+06 O.OOE+OO O.OOE+OO O.OOE+00 9.53E+06 O.OOE+OO CO-60 O.OOE+OO 1.53E+06 3.37E+06 O.OOE+OO O.OOE+OO O.OOE+00 2.87E+07 O.OOE+OO NI-63 6.25E+08 4.33E+07 2.10E+07 O.OOE+00 O.OOE+OO O.OOE+OO 9.03E+06 O.OOE+OO NI-65 4.51E-02 5.86E-03 2.67E-03 O.OOE+OO O.OOE+OO O.OOE+00 1.49E-O1 O.OOE+OO CU-64 O.OOE+OO 2.66E+03 1.25E+03 O.OOE+00 6.71E+03 O.OOE+OO 2.27E+05 O.OOE+OO ZN-65 1.30E+08 4.15E+08 1.88E+08 O.OOE+OO 2.78E+08 O.OOE+OO 2.61E+08 O.OOE+OO ZN-69 2.62E-13 5.OOE-13 3.48E-14 O.OOE+OO 3.25E-13 O.OOE+00 7.52E-14 O.OOE+OO ZN-69M O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 1.18E-02 O.OOE+OO O.OOE+OO O.OOE+OO 1.71E-02 O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 2.08E-24 O.OOE+OO O.OOE+OO O.OOE+OO 1.63E-29 O.OOE+OO BR-85 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 2.88E+08 1.34E+08 O.OOE+OO O.OOE+OO O.OOE+OO 5.68E+07 O.OOE+OO RB-88 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-89 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SR-89 2.59E+09 O.OOE+OO 7.43E+07 O.OOE+OO O.OOE+OO O.OOE+OO 4.15E+08 O.OOE+OO SR-90 7.61E+10 O.OOE+OO 1.87E+10 O.OOE+OO O.OOE+OO O.OOE+OO 2.20E+09 O.OOE+OO SR-91 6.10E+04 O.OOE+OO 2.46E+03 O.OOE+OO O.OOE+OO O.OOE+OO 2.90E+05 O.OOE+OO SR-92 1.04E+OO O.OOE+OO 4.50E-02 O.OOE+OO O.OOE+OO O.OOE+OO 2.06E+O1 O.OOE+OO Y-90 8.50E+OO O.OOE+OO 2.28E-O1 O.OOE+OO O.OOE+OO O.OOE+00 9.02E+04 O.OOE+OO Y-91M 7.52E-21 O.OOE+OO 2.91E-22 O.OOE+OO O.OOE+OO O.OOE+OO 2.21E-20 O.OOE+OO Y-91 8.67E+02 O.OOE+OO 2.32E+O1 O.OOE+OO O.OOE+OO O.OOE+OO 4.77E+05 O.OOE+OO Y-92 6.77E-06 O.OOE+OO 1.98E-07 O.OOE+OO O.OOE+OO O.OOE+OO 1.19E-OI O.OOE+OO Y-93 2.69E-02 O.OOE+OO 7.43E-04 O.OOE+OO O.OOE+OO O.OOE+OO 8.53E+02 O.OOE+OO ZR-95 9.47E+01 3.04E+01 2.06E+O1 O.OOE+OO 4.76E+O1 O.OOE+OO 9.62E+04 O.OOE+OO ZR-97 5.21E-02 1.05E-02 4.81E-03 O.OOE+00 1.59E-02 O.OOE+00 3.26E+03 O.OOE+00 NB-95 8.67E+03 4.82E+03 2.59E+03 O.OOE+00 4.77E+03 O.OOE+00 2.93E+07 O.OOE+00 NB-97 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+00 MO-99 O.OOE+00 2.97E+06 5.66E+05 O.OOE+00 6.73E+06 O.OOE+00 6.89E+06 O.OOE+00 TC-99M 4.01E-01 1.13E+00 1.44E+01 O.OOE+00 1.72E+01 5.55E-01 6.71E+02 O.OOE+00 TC-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RU-103 1.06E+02 O.OOE+OO 4.56E+01 O.OOE+00 4.04E+02 O.OOE+0O 1.24E+04 O.OOE+00 RU-105 1.04E.04 O.OOE+00 4.09E-05 O.OOE+00 1.34E-03 O.OOE+00 6.34E-02 O.OOE+00 RU-106 1.92E+03 O.OOE+00 2.43E+02 O.OOE+00 3.71E+03 O.OOE+00 1.25E+05 O.OOE+00 AG-llOM 5.53E+06 5.12E+06 3.04E+06 O.OOE+00 1.O1E+07 O.OOE+00 2.09E+09 O.OOE+00 SB-124 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 SB-125 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 TE-125M 1.65E+06 5.96E+05 2.20E+05 4.95E+05 6.69E+06 O.OOE+00 6.57E+06 O.OOE+00 TE-127M 4.47E+06 1.60E+06 5.44E+05 1.14E+06 1.81E+07 O.OOE+00 1.50E+07 O.OOE+00 TE-127 7.87E+01 2.82E+01 1.70E+01 5.83E+01 3.20E+02 O.OOE+00 6.21E+03 O.OOE+00 TE-129M 6.34E+06 2.37E+06 1.OOE+06 2.18E+06 2.65E+07 0.OOE+00 3.19E+07 O.OOE+00 TE-129 3.50E-11 1.32E-11 8.53E-12 2.69E-11 1.47E-10 O.OOE+00 2.64E-I1 O.OOE+0O RSP-0008 REV-13 PAC.E 79 OF 14d

INFORMATION USE ATTACHMENT 24 PAGE 2 OF 2 TABLE 1-10: DOSE FACTOR TABLE: R (I) - ADULT, GOATS MILK Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 4.34E+04 2.12E+04 1.77E+04 3.36E+04 2.15E+05 0.OOE+00 2.11E+06 0.OOE+00 TE-131 4.74E-34 1.98E-34 1.50E-34 3.90E-34 2.08E-33 0.OOE+00 6.72E-35 O.OOE+00 TE-132 2.88E+05 1.86E1+05 1.75E+05 2.06E+05 1.80E+06 O.OOE+00 8.82E+06 0.OOE+00 1-130 5.06E+05 1.49E+06 5.89E+05 1.26E+08 2.33E+06 O.OOE+00 1.28E+06 O.OOE+00 1-131 3.49E+08 4.99E+08 2.86E+08 1.64E+11 8.56E+08 0.OOE+00 1.32E+08 O.OOE+00 1-132 2.OOE-01 5.36E-01 1.88E-01 1.88E+01 8.54E-01 0.OOE+00 1.O1E-01 O.OOE+00 1-133 4.65E+06 8.09E+06 2.47E+06 1.19E+09 1.41E+07 0.OOE+00 7.27E+06 O.OOE+00 1-134 2.53E-12 6.87E-12 2.46E-12 1.19E-10 1.09E-11 O.OOE+00 5.99E-15 0.OOE+00 I-135 1.55E+04 4.06E+04 1.50E+04 2.68E+06

- 6.51E+04 O.OOE+00 4.58E+04 O.OOE+00 CS-134 1.32E+10 3.15E+10 2.57E+10 0.OOE+00 1.02E+10 3.38E+09 5.51E+08 O.OOE+00 CS-136 7.53E+08 2.97E+09 2.14E+09 0.OOE+00 1.65E+09 2.27E+08 3.38E+08 0.OOE+00 CS-137 1.71E+10 2.34E+10 1.54E+10 O.OOE+00 7.96E+09 2.65E+09 4.54E+08 O.OOE+00 CS-138 2.91E-23 5.76E-23 2.85E-23 O.OOE+00 4.23E-23 4.18E-24 2.46E-28 O.OOE+00 BA-139 5.45E-09 3.88E-12 1.60E-10 0.OOE+00 3.63E-12 2.20E-12 9.67E-09 0.OOE+00 BA-140 3.08E+06 3.87E+03 2.02E+05 0.OOE+00 1.32E+03 2.22E+03 6.35E+06 0.OOE+00 BA-141 0.OOE+00 O.OOE+00 O.OOE+00 OOOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 BA-142 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 LA-140 5.42E-01 2.73E-01 7.22E-02 O.OOE+00 O.OOE+00 0.OOE+00 2.00E+04 0.OOE+00 LA-142 2.28E-12 1.04E-12 2.59E-13 0.OOE+00 O.OOE+00 O.OOE+00 7.58E-09 O.OOE+00 CE-141 5.12E+02 3.46E+02 3.93E+01 O.OOE+00 1.61E+02 0.OOE+00 1.32E+06 O.OOE+00 CE-143 4.99E+00 3.69E+03 4.09E-01 O.OOE+00 1.63E+00 0.OOE+00 1.38E+05 0.OOE+00 CE-144 3.39E+04 1.42E+04 1.82E+03 O.OOE+00 8.40E+03 0.OOE+00 1.15E+07 0.OOE+00 PR-143 1.80E+01 7.23E+00 8.93E-01 0.OOE+00 4.17E+00 O.OOE+00 7.89E+04 O.OOE+00 PR-144 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 ND-147 1.09E+01 1.26E+01 7.55E-01 0.OOE+00 7.37E+00 0.OOE+00 6.06E+04 O.OOE+00 W-187 7.82E+02 6.54E+02 2.29E+02 O.OOE+00 O.OOE+00 O.OOE+00 2.14E+05 0.OOE+00 NP-239 4.41E-01 4.34E-02 2.39E-02 O.OOE+00 1.35E-01 0.OOE+00 8.89E+03 O.OOE+00 RSP-0008 REV-13 PAGE 80 OF 104

INFORMATION USE ATTACHMENT 25 PAGE 1 OF 2 TABLE I-1l: DOSE FACTOR TABLE: R (I) - TEEN, GOATS MILK TABLE I-11 DOSE FACTOR TABLE: R (i) - Teen, goats' milk Units are m2 *mrem/yr per lCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 C-14 6.70E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 1.34E+05 NA-24 5.12E+05 5.12E+05 5.12E+05 5.12E+05 5.12E+05 5.12E+05 P-32 3.58E+10 2.22E+09 1.39E+09 O.OOE+OO O.OOE+OO O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 5.35E+03 2.97E+03 1.17E+03 7.64E+03 MN-54 O.OOE+OO 1.33E+06 2.63E+05 O.OOE+OO 3.95E+05 O.OOE+OO MN-56 O.OOE+OO 8.95E-04 1.59E-04 O.OOE+OO 1.13E-03 O.OOE+OO FE-55 4.51E+05 3.19E+05 7.45E+04 O.OOE+OO O.OOE+OO 2.03E+05 FE-59 5.78E+05 1.35E+06 5.21E+05 O.OOE+OO O.OOE+OO 4.25E+05 CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 7.92E+05 1.82E+06 O.OOE+OO O.OOE+OO O.OOE+OO CO-60 O.OOE+OO 2.59E+06 5.83E+06 O.OOE+OO O.OOE+OO O.OOE+OO NI-63 1.lOE+09 7.75E+07 3.72E+07 O.OOE+OO O.OOE+OO O.OOE+OO NI-65 8.25E-02 1.05E-02 4.80E-03 O.OOE+OO O.OOE+OO O.OOE+OO CU-64 O.OOE+OO 4.74E+03 2.23E+03 O.OOE+OO 1.20E+04 O.OOE+OO ZN-65 2.OOE+08 6.95E+08 3.24E+08 O.OOE+OO 4.45E+08 O.OOE+OO ZN-69 4.82E-13 9.18E-13 6.42E-14 O.OOE+OO 6.OOE-13 O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 2.18E-02 O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 3.71E-24 O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 5.25E+08 2.47E+08 O.OOE+OO O.OOE+OO O.OOE+OO RB-88 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-89 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO SR-89 4.77E+09 O.OOE+OO 1.37E+08 O.OOE+OO O.OOE+OO O.OOE+OO SR-90 1.07E+I I O.OOE+OO 2.65E+10 O.OOE+OO O.OOE+OO O.OOE+OO SR-91 1.12E+05 O.OOE+OO 4.46E+03 O.OOE+OO O.OOE+OO O.OOE+OO SR-92 1.90E+OO O.OOE+OO 8.1 IE-02 O.OOE+OO O.OOE+OO O.OOE+OO Y-90 1.56E+O1 O.OOE+OO 4.21E-O1 O.OOE+OO O.OOE+OO O.OOE+OO Y-91M 1.38E-20 O.OOE+OO S.26E-22 O.OOE+OO O.OOE+OO O.OOE+OO Y-91 1.59E+03 O.OOE+OO 4.28E+O1 O.OOE+OO O.OOE+OO O.OOE+OO Y-92 1.25E-05 O.OOE+OO 3.62E-07 O.OOE+OO O.OOE+OO O.OOE+OO Y-93 4.96E-02 O.OOE+OO 1.36E-03 O.OOE+OO O.OOE+OO O.OOE+OO ZR-95 1.66E+02 5.22E+01 3.59E+O1 O.OOE+OO 7.67E+O1 O.OOE+OO ZR-97 9.48E-02 1.88E-02 8.64E-03 O.OOE+OO 2.84E-02 O.OOE+OO NB-95 1.48E+04 8.20E+03 4.51E+03 O.OOE+OO 7.95E+03 O.OOE+OO NB-97 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO MO-99 O.OOE+OO 5.37E+06 1.02E+06 O.OOE+OO 1.23E+07 O.OOE+OO TC-99M 6.96E-01 1.94E+00 2.51E+O1 O.OOE+OO 2.89E+01 1.08E+OO TC-1O1 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RU-103 1.88E+02 O.OOE+OO 8.05E+O1 O.OOE+OO 6.64E+02 O.OOE+OO RU-105 1.89E-04 O.OOE+OO 7.35E-05 O.OOE+OO 2.39E-03 O.OOE+OO RU-106 3.54E+03 O.OOE+OO 4.46E+02 O.OOE+OO 6.82E+03 O.OOE+OO AG-llOM 9.14E+06 8.65E+06 5.26E+06 O.OOE+OO 1.65E+07 O.OOE+OO SB-124 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 3.03E+06 l.09E+06 4.06E+05 8.48E+05 O.OOE+OO O.OOE+OO TE-127M 8.23E+06 2.92E+06 9.79E+05 1.96E+06 3.34E+07 O.OOE+OO TE-127 1.46E+02 5.17E+01 3.14E+O1 1.01E+02 5.91E+02 O.OOE+OO TE-129M 1.16E+07 4.31E+06 1.84E+06 3.74E+06 4.85E+07 O.OOE+OO TE-129 6.45E-11 2.40E-11 1.57E-11 4.61E-11 2.71E-10 O.OOE+OO 1.26E+03 1.34E+05 5.12E+05 3.01E+09 8.99E+05 2.72E+06 5.89E-02 1.38E+05 3.19E+06 O.OOE+OO 1.09E+07 3.37E+07 1.23E+07 5.72E-O1 3.68E+05 2.94E+08 1.69E-12 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 7.77E+07 O.OOE+OO O.OOE+OO 5.69E+08 3.02E+09 5.08E+05 4.85E+O1 1.29E+05 6.50E-19 6.54E+05 3.43E-O1 1.52E+03 1.21E+05 5.08E+03 3.51E+07 O.OOE+OO 9.61E+06 1.27E+03 O.OOE+OO 1.57E+04 l.53E-OI 1.70E+05 2.43E+09 O.OOE+OO O.OOE+OO 8.95E+06 2.05E+07 1.13E+04 4.36E+07 3.53E-10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RSP-0008 REV-13 PAGE 81 OF 104

INFORMATION USE ATTACHMENT 25 PAGE 2 OF 2 TABLE I-ll: DOSE FACTOR TABLE: R (I) - TEEN, GOATS MILK Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 7.89E+04 3.79E+04 3.16E+04 5.69E+04 3.95E+05 TE-131 8.67E-34 3.57E-34 2.71E-34 6.68E-34 3.79E-33 TE-132 5.15E+05 3.26E+05 3.07E+05 3.44E+05 3.13E+06 1-130 8.89E+05 2.57E+06 1.03E+06 2.10E+08 3.96E+06 1-131 6.33E+08 8.87E+08 4.76E+08 2.59E+11 1.53E+09 1-132 3.55E-01 9.30E-01 3.34E-01 3.13E+01 1.47E+00 I-133 8.50E+06 1.44E+07 4.40E+06 2.01E+09 2.53E+07 1-134 4.49E-12 1.19E-11 4.28E-12 1.98E-10 I.88E-11 1-135 2.75E+04 7.09E+04 2.63E+04 4.56E+06 1.12E+05 CS-134 2.30E+10 5.40E+10 2.51E+10 0.OOE+00 1.72E+10 CS-136 1.28E+09 5.04E+09 3.39E+09 O.OOE+00 2.75E+09 CS-137 3.11E+10 4.13E+10 1.44E+10 0.OOE+00 1.41E+10 CS-138 5.29E-23 1.02E-22 5.08E-23 O.OOE+00 7.49E-23 BA-139 1.O1E-08 7.09E-12 2.94E-10 0.OOE+00 6.69E-12 BA-140 5.56E+06 6.82E+03 3.58E+05 0.OOE+00 2.31E+03 BA-141 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 BA-142 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 LA-140 9.73E-01 4.78E-01 1.27E-01 0.OOE+00 0.OOE+00 LA-142 4.12E-12 1.83E-12 4.56E-13 0.OOE+00 0.OOE+00 CE-141 9.39E+02 6.27E+02 7.20E+01 0.OOE+00 2.95E+02 CE-143 9.18E+00 6.68E+03 7.46E-01 O.OOE+00 2.99E+00 CE-144 6.24E+04 2.58E1+04 3.35E+03 O.OOE+00 1.54E+04 PR-143 3.31E+01 1.32E+01 1.65E+00 O.OOE+00 7.68E+00 PR-144 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 ND-147 2.10E+01 2.28E+01 1.37E+00 O.OOE+00 1.34E+01 W-187 1.43E+03 1.17E+03 4.08E+02 0.OOE+00 O.OOE+00 NP-239 8.42E-01 7.94E-02 4.41E-02 O.OOE+00 2.49E-01 0.OOE1+00 0.OOE+00 0.OOE3+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE1+00 0.OOE3+00 0.OOE3+00 6.561E+09 4.331E+08 5.47E+09 8.72E-24 4.89E-12 4.58E+03 0.OOE1+00 0.OOE1+00 0.OOE1+00 0.OOE+00 0.OOE1+00 0.OOE3+00 0.OOE+00 0.OOE1+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE1+00 3.04E3+06 7.1 1E-35 1.03E+07 1.98E+06 1.751E+08 4.05E-01 1.091E+07 1.57E3-13 7.85E3+04 6.72E3+08 4.06E+08 5.881E+08 4.61E3-26 8.991E-08 8.58E+06 0.OOE+00 0.OOE1+00 2.751E+04 5.57E-08 1.79E+06 2.01E3+05 1.571E+07 1.091E+05 0.OOE1+00 8.241E+04 3.15E+05 1.281E+04 0.OOE+00 0.OO3+O00 O.OOE1+00 0.OOE+00 0.OOE1+00 0.OO1+O00 0.OO1+O00 0.OOE+00 0.OOE1+00 0.OOE3+00 0.OOE1+00 O.OOE+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE1+00 0.OOE3+00 0.OOE+00 0.OE3+O00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OO1+O00 0.OE3+O00 0.OOE+00 RSP-0008 REV - 13 PAGE 82 OF 104

R-INFORMATION USE ATTACHMENT 26 PAGE 1 OF2 TABLE 1-12: DOSE FACTOR TABLE: R (1) - CHILD, GOATS MILK TABLE I-12 DOSE FACTOR TABLE: R (i) - Child, goats' milk Units are m2*mremlyr per pCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 1.99E+03 1.99E+03 1.99E+03 l.99E+03 1.99E+03 1.99E+03 O.OOE+OO C-14 1.65E+06 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 3.29E+05 O.OOE+00 NA-24 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 O.OOE+O0 P-32 8.84E+10 4.14E+09 3.41E+09 O.OOE+O0 O.OOE+O0 O.OOE+O0 2.44E+09 O.OOE+00 CR-51 O.OOE+00 O.OOE+00 1.09E+04 6.05E+03 1.65E+03 1.11E+04 5.79E+05 O.OOE+00 MN-54 O.OOE+OO 1.98E+06 5.28E+05 O.OOE+O0 5.56E+05 O.OOE+O0 1.66E+06 O.OOE+OO MN-56 O.OOE+00 1.56E-03 3.53E-04 O.OOE+OO 1.89E-03 O.OOE+0O 2.26E-O1 O.OOE+00 FE-55 1.13E+06 6.OOE+05 1.86E+05 O.OOE+0O O.OOE+00 3.39E+05 I.I1E+05 O.OOE+00 FE-59 1.34E+06 2.17E+06 1.08E+06 O.OOE+00 O.OOE+0O 6.29E+05 2.26E+06 O.OOE+00 CO-57 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+0O O.OOE+0O O.OOE+00 O.OOE+00 CO-58 O.OOE+00 1.21E+06 3.70E+06 O.OOE+00 O.OOE+00 O.OOE+00 7.05E+06 O.OOE+OO CO-60 O.OOE+00 4.02E+06 1.19E+07 O.OOE+0O O.OOE+00 O.OOE+OO 2.23E+07 O.OOE+O0 NI-63 2.75E+09 1.47E+08 9.36E+07 O.OOE+OO O.OOE+OO O.OOE+OO 9.92E+06 O.OOE+OO NI-65 2.02E-01 1.90E-02 1.I IE-02 O.OOE+00 O.OOE+00 O.OOE+00 2.33E+0O O.OOE+O0 CU-64 O.OOE+00 8.34E+03 5.04E+03 O.OOE+00 2.02E+04 O.OOE+OO 3.91E+05 O.OOE+O0 ZN-65 3.93E+08 1.05E+09 6.51E+08 O.OOE+00 6.60E+08 O.OOE+00 1.84E+08 O.OOE+O0 ZN-69 1.18E-12 1.71E-12 1.58E-13 O.OOE+00 1.04E-12 O.OOE+O0 1.08E-10 O.OOE+OO ZN-69M O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+O0 BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+O0 O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+00 BR-83 O.OOE+O0 O.OOE+00 S.36E-02 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+O0 BR-84 O.OOE+0O O.OOE+00 8.40E-24 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 BR-85 O.OOE+0O O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+0O RB-86 O.OOE+00 9.74E+08 5.99E+08 O.OOE+OO O.OOE+0O O.OOE+O0 6.27E+07 O.OOE+O0 RB-88 O.OOE+OO O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 RB-89 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO SR-89 1.18E+10 O.OOE+0O 3.37E+08 O.OOE+O0 O.OOE+O0 O.OOE+00 4.57E+08 O.OOE+O0 SR-90 1.82E+1 1 O.OOE+00 4.60E+10 O.OOE+00 O.OOE+00 O.OOE+O0 2.45E+09 O.OOE+O0 SR-91 2.75E+05 O.OOE+OO 1.04E+04 O.OOE+0O O.OOE+00 O.OOE+00 6.07E+05 O.OOE+O0 SR-92 4.65E+OO O.OOE+OO 1.86E-01 O.OOE+OO O.OOE+O0 O.OOE+00 8.81E+O1 O.OOE+OO Y-90 3.87E+O1 O.OOE+O0 1.04E+00 O.OOE+0O O.OOE+OO O.OOE+00 1.lOE+05 O.OOE+O0 Y-91M 3.36E-20 O.OOE+OO 1.22E-21 O.OOE+00 O.OOE+00 O.OOE+0O 6.56E-17 O.OOE+OO Y-91 3.94E+03 O.OOE+00 1.05E+02 O.OOE+OO O.OOE+O0 O.OOE+00 5.25E+05 O.OOE+O0 Y-92 3.07E-05 O.OOE+OO 8.78E-07 O.OOE+OO 0.OOE+00 O.OOE+OO 8.87E-O1 O.OOE+O0 Y-93 1.22E-O1 O.OOE+0O 3.35E-03 O.OOE+00 O.OOE+00 O.OOE+00 1.82E+03 O.OOE+00 ZR-95 3.85E+02 8.45E+01 7.53E+O1 O.OOE+0O 1.21E+02 O.OOE+00 8.82E+04 O.OOE+00 ZR-97 2.31E-01 3.33E-02 1.97E-02 O.OOE+OO 4.79E-02 O.OOE+OO 5.05E+03 O.OOE+OO NB-95 3.34E+04 1.30E+04 9.29E+03 O.OOE+00 1.22E+04 O.OOE+00 2.40E+07 O.OOE+00 NB-97 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+O0 O.OOE+0O O.OOE+00 O.OOE+O0 MO-99 O.OOE+00 9.77E+06 2.42E+06 O.OOE+OO 2.09E+07 O.OOE+OO 8.08E+06 O.OOE+00 TC-99M 1.60E+00 3.13E+00 5.19E+01 O.OOE+OO 4.55E+01 1.59E+00 1.78E+03 O.OOE+00 TC-101 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+OO O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+O0 RU-103 4.45E+02 O.OOE+OO 1,71E+02 O.OOE+0O 1.12E+03 O.OOE+OO 1.15E+04 O.OOE+OO RU-105 4.62E-04 O.OOE+OO 1.68E-04 O.OOE+OO 4.06E-03 O.OOE+OO 3.02E-01 O.OOE+OO RU-106 8.71E+03 O.OOE+OO I.09E+03 O.OOE+OO 1.18E+04 O.OOE+OO 1.36E+05 O.OOE+OO AG-110M 1.98E+07 1.34E+07 1.07E+07 O.OOE+OO 2.SOE+07 O.OOE+OO 1.59E+09 O.OOE+OO SB-124 O.OOE+O0 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 7.45E+06 2.02E+06 9.94E+05 2.09E+06 O.OOE+OO O.OOE+OO 7.19E+06 O.OOE+OO TE-127M 2.03E+07 5.46E+06 2.41E+06 4.85E+06 5.79E+07 O.OOE+OO 1.64E+07 O.OOE+OO TE-127 3.59E+02 9.67E+01 7.69E+01 2.48E+02 1.02E+03 O.OOE+OO 1.40E+04 O.OOE+OO TE-129M 2.86E+07 7.99E+06 4.44E+06 9.22E+06 8.40E+07 O.OOE+OO 3.49E+07 O.OOE+OO TE-129 1.59E-10 4.44E-11 3.78E-1 1 1.14E-10 4.65E-10 O.OOE+OO 9.90E-09 O.OOE+OO RSP-0008 REV-13 PAGE 83 OF 104

INFORMATION USE ATTACHMENT 26 PAGE 2 OF 2 TABLE I-12: DOSE FACTOR TABLE: R (I) - CHILD, GOATS MILK Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M TE-131 TE-132 1-130 I-131 1-132 1-133 1-134 1-135 CS-134 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 W-187 NP-239 1.92E+05 2.13E-33 1.23E+06 2.08E+06 1.54E+09 8.41E-01 2.06E+07 1.06E-11 6.52E+04 5.30E+10 2.89E+09 7.49E+10 1.28E-22 2.48E-08 1.34E+07 O.OOE+00 O.OOE+00 2.33E+00 9.95E-12 2.31E+03 2.25E+01 1.54E+05 8.19E+01 O.OOE+00 5.15E+01 3.47E+03 2.07E+00 6.65E+04 7.07E+04 6.48E-34 6.33E-34 5.44E+05 6.57E+05 4.20E+06 2.16E+06 1.55E+09 8.78E+08 1.54E+00 7.10E-01 2.55E+07 9.66E+06 1.98E-11 9.09E-12 1.17E+05 5.55E+04 8.69E+10 1.83E+10 7.59E+09 5.15E+09 7.17E+10 1.06E+10 1.78E-22 1.13E-22 1.32E-11 7.18E-10 1.18E+04 7.84E+05 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 8.14E-01 2.75E-01 3.17E-12 9.94E-13 1.15E+03 1.71E+02 1.22E+04 1.77E+00 4.82E+04 8.21E+03 2.46E+01 4.07E+00 O.OOE+00 O.OOE+00 4.17E+01 3.23E+00 2.05E+03 9.21E+02 1.49E-01 1.05E-01 1.37E+05 1.63E-33 7.93E+05 4.63E+08 5.11E3+11 7.17E+01 4.74E+09 4.54E-10 1.04E+07 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+O0 0.OOE+O0 0.OOE+00 6.43E+05 O.OOE+00 6.43E-33 O.OOE+00 5.05E+06 O.OOE+00 6.28E+06 O.OOE+00 2.54E+09 O.OOE+00 2.36E+00 O.OOE+00 4.25E+07 0.OOE+00 3.02E-11 O.OOE+00 1.80E+05 O.OOE+00 2.69E+10 9.66E+09 4.24E+09 6.32E+08 2.33E+10 8.40E+09 1.25E-22 1.35E-23 1.15E-11 7.78E-12 3.83E+03 7.01E+03 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 5.05E+02 O.OOE+00 5.12E+00 O.OOE+00 2.67E+04 O.OOE+00 1.33E+01 O.OOE+00 O.OOE+00 O.OOE+00 2.29E+01 O.OOE+00 O.OOE+00 O.OOE+00 4.30E-01 O.OOE+00 2.70E+06 1.12E-32 5.48E+06 1.97E+06 1.38E+08 1.82E+00 1.03E+07 1.31E-11 8.94E+04 4.68E+08 2.80E+08 4.49E+08 8.21E-23 1.43E-06 6.80E+06 O.OOE+00 O.OOE+00 2.27E+04 6.29E-07 1.44E+06 1.79E+05 1.26E+07 8.84E+04 O.OOE+00 6.61E+04 2.89E+05 1.1OE+04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE3+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+O0 0.OOE+00 RSP-0008 REV-13 PAGE 84 OF 104

9

INFORMATION USE ATTACHMENT 27 PAGE 1 OF 2 TABLE 1-13: DOSE FACTOR TABLE: R (I) - INFANT, GOATS MILK TABLE 1-13 DOSE FACTOR TABLE: R (i) - Infant, goats' milk Units are m2*mrem/yr per gCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+00 3.01E+03 3.01E+03 3.01E+03 3.01E+03 C-14 3.23E+06 6.89E+05 6.89E+05 6.89E+05 6.89E+05 NA-24 1.85E+06 1.85E+06 1.85E+06 1.85E+06 1.85E+06 P-32 1.82E+11 1.07E+10 7.06E+09 O.OOE+00 O.OOE+00 CR-51 O.OOE+00 O.OOE+00 1.71E+04 1.13E+04 2.46E+03 MN-54 O.OOE+00 3.69E+06 8.36E+05 O.OOE+00 8.17E+05 MN-56 O.OOE+00 3.82E-03 6.59E-04 O.OOE+00 3.29E-03 FE-55 1.37E+06 8.83E+05 2.36E+05 O.OOE+00 O.OOE+00 FE-59 2.50E+06 4.37E+06 1.72E+06 O.OOE+00 O.OOE+00 CO-57 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 CO-58 O.OOE+00 2.42E+06 6.03E+06 O.OOE+00 O.OOE+00 CO-60 O.OOE+00 8.21E+06 1.94E+07 O.OOE+00 O.OOE+00 NI-63 3.24E+09 2.01E+08 1.13E+08 O.OOE+00 O.OOE+00 NI-65 4.27E-01 4.83E-02 2.20E-02 O.OOE+00 O.OOE+00 CU-64 O.OOE+00 2.07E+04 9.60E+03 O.OOE+00 3.51E+04 ZN-65 5.28E+08 1.81E+09 8.35E+08 O.OOE+00 8.78E+08 ZN-69 2.52E-12 4.54E-12 3.38E-13 O.OOE+00 1.89E-12 ZN-69M O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 BR-82 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 BR-83 O.OOE+00 O.OOE+00 1.14E-01 O.OOE+00 O.OOE+00 BR-84 O.OOE+00 O.OOE+00 1.62E-23 O.OOE+00 O.OOE+00 BR-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RB-86 O.OOE+00 2.47E+09 1.22E+09 O.OOE+00 O.OOE+00 RB-88 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RB-89 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 SR-89 2.25E+10 O.OOE+00 6.44E+08 O.OOE+00 O.OOE+00 SR-90 1.98E+II O.OOE+00 5.03E+10 O.OOE+00 O.OOE+00 SR-91 5.73E+05 O.OOE+00 2.07E+04 O.OOE+00 O.OOE+00 SR-92 9.89E+00 O.OOE+00 3.67E-01 O.OOE+00 O.OOE+00 Y-90 8.18E+01 O.OOE+00 2.19E+00 O.OOE+00 O.OOE+00 Y-91M 7.13E-20 O.OOE+00 2.43E-21 O.OOE+00 O.OOE+00 Y-91 7.40E+03 O.OOE+00 1.97E+02 O.OOE+00 O.OOE+00 Y-92 6.52E-05 O.OOE+00 1.83E-06 O.OOE+00 O.OOE+00 Y-93 2.60E-01 O.OOE+00 7.08E-03 O.OOE+00 O.OOE+00 ZR-95 6.83E+02 1.66E+02 1.18E+02 O.OOE+00 1.79E+02 ZR-97 4.89E-01 8.38E-02 3.83E-02 O.OOE+00 8.45E-02 NB-95 6.23E+04 2.57E+04 1.48E+04 O.OOE+00 1.84E+04 NB-97 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 MO-99 O.OOE+00 2.50E+07 4.87E+06 O.OOE+00 3.73E+07 TC-99M 3.32E+00 6.84E+00 8.82E+01 O.OOE+00 7.36E+01 TC-101 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RU-103 9.02E+02 O.OOE+00 3.02E+02 O.OOE+00 1.88E+03 RU-105 9.75E-04 O.OOE+00 3.28E-04 O.OOE+00 7.17E-03 RU-106 1.79E+04 O.OOE+00 2.24E+03 O.OOE+00 2.12E+04 AG-I IOM 3.67E+07 2.68E+07 1.77E+07 O.OOE+00 3.83E+07 SB-124 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 SB-125 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TE-125M 1.52E+07 5.09E+06 2.06E+06 5.12E+06 O.OOE+00 TE-127M 4.11E+07 1.36E+07 4.97E+06 1.19E+07 1.01E+08 TE-127 7.61E+02 2.55E+02 1.64E+02 6.20E+02 1.86E+03 TE-129M 5.87E+07 2.01E+07 9.04E+06 2.25E+07 1.47E+08 TE-129 3.37E-10 1.16E-10 7.87E-11 2.83E-10 8.40E-10 3.01E+03 3.01E+03 6.89E+05 6.89E+05 1.85E+06 1.85E+06 O.OOE+00 2.46E+09 2.19E+04 5.04E+05 O.OOE+00 1.36E+06 O.OOE+00 3.47E-01 4.32E+05 1.12E+05 1.29E+06 2.09E+06 O.OOE+00 O.OOE+00 O.OOE+00 6.03E+06 O.OOE+00 1.95E+07 O.OOE+00 9.98E+06 O.OOE+00 3.68E+00 O.OOE+00 4.25E+05 O.OOE+00 1.53E+09 O.OOE+00 3.70E-10 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6.33E+07 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4.62E+08 O.OOE+00 2.47E+09 O.OOE+00 6.78E+05 O.OOE+00 1.07E+02 O.OOE+00 1.13E+05 O.OOE+00 2.38E-16 O.OOE+00 5.30E+05 O.OOE+00 1.24E+00 O.OOE+00 2.05E+03 O.OOE+00 8.29E+04 O.OOE+00 5.35E+03 O.OOE+00 2.17E+07 O.OOE+00 O.OOE+00 O.OOE+00 8.23E+06 3.58E+00 1.99E+03 O.OOE+00 O.OOE+00 O.OOE+00 1.10E+04 O.OOE+00 3.88E-01 O.OOE+00 1.36E+05 O.OOE+00 1.39E+09 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 7.26E+06 O.OOE+00 1.66E+07 O.OOE+00 1.60E+04 O.OOE+00 3.51E+07 O.OOE+00 2.70E-08 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RSP-0008 REV-13 PAGE 85 OF 104

INFORMATION USE ATTACHMENT 27 PAGE 2 OF 2 TABLE I-13: DOSE FACTOR TABLE: R (I) - INFANT, GOATS MILK Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 4.06E+05 1.63E+05 1.35E+05 3.31E+05 1.12E+06 O.OOE+00 2.75E+06 O.OOE+00 TE-131 4.51E-33 1.67E-33 1.27E-33 4.02E-33 1.15E-32 O.OOE+00 1.82E-31 O.OOE+00 TE-132 2.53E+06 1.25E+06 1.17E+06 1.85E+06 7.84E+06 O.OOE+00 4.64E+06 O.OOE+00 1-130 4.27E+06 9.40E+06 3.77E+06 1.05E+09 1.03E+07 O.OOE+00 2.01E+06 O.OOE+00 1-131 3.21E+09 3.78E+09 1.66E+09 1.24E+12 4.41E+09 O.OOE+00 1.35E+08 O.OOE+00 I-132 1.74E+00 3.54E+00 1.26E+00 1.66E+02 3.95E+00 O.OOE+00 2.87E+00 O.OOE+00 1-133 4.36E+07 6.35E+07 1.86E+07 1.15E+10 7.46E+07 O.OOE+00 1.07E+07 O.OOE+00 I-134 2.21E-11 4.52E-11 1.61E-11 1.05E-09 5.05E-11 O.OOE+00 4.67E-11 O.OOE+00 I-135 1.36E+05 2.70E+05 9.83E+04 2.42E+07 3.OOE+05 O.OOE+00 9.76E+04 O.OOE+00 CS-134 8.53E+10 1.59E+11 1.61E+10 O.OOE+00 4.10E+10 1.68E+10 4.32E+08 O.OOE+00 CS-136 5.65E+09 1.66E+10 6.21E+09 O.OOE+00 6.62E+09 1.35E+09 2.52E+08 O.OOE+00 CS-137 1.19E+11 1.40E+11 9.91E+09 O.OOE+00 3.75E+10 1.52E+10 4.37E+08 O.OOE+00 CS-138 2.70E-22 4.40E-22 2.13E-22 O.OOE+00 2.19E-22 3.42E-23 7.03E-22 O.OOE+00 BA-139 5.27E-08 3.49E-11 1.53E-09 O.OOE+00 2.10E-11 2.12E-1 1 3.34E-06 O.OOE+00 BA-140 2.76E+07 2.76E+04 1.42E+06 O.OOE+00 6.56E+03 1.70E+04 6.79E+06 O.OOE+00 BA-141 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 BA-142 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LA-140 4.87E+00 1.92E+00 4.94E-01 O.OOE+00 O.OOE+00 O.OOE+00 2.25E+04 O.OOE+00 LA-142 2.09E-11 7.67E-12 1.84E-12 O.OOE+00 O.OOE+00 O.OOE+00 1.30E-06 O.OOE+00 CE-141 4.58E+03 2.79E+03 3.29E+02 O.OOE+00 8.62E+02 O.OOE+00 1.44E+06 O.OOE+00 CE-143 4.77E+01 3.16E+04 3.61E+00 O.OOE+00 9.21E+00 O.OOE+00 1.85E+05 O.OOE+00 CE-144 2.20E+05 9.02E+04 1.23E+04 O.OOE+00 3.64E+04 O.OOE+00 1.26E+07 O.OOE+00 PR-143 1.70E+02 6.34E+01 8.40E+00 O.OOE+00 2.36E+01 O.OOE+00 8.95E+04 O.OOE+00 PR-144 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 ND-147 1.02E+02 1.05E+02 6.43E+00 O.OOE+00 4.05E+01 O.OOE+00 6.65E+04 O.OOE+00 W-187 7.30E+03 5.08E+03 1.75E+03 O.OOE+00 O.OOE+00 O.OOE+00 2.98E+05 O.OOE+00 NP-239 4.38E+00 3.92E-01 2.21E-01 O.OOE+00 7.81E-01 O.OOE+00 1.13E+04 O.OOE+00 RSP-0008 REV-13 PAGE 86 OF 104

W INFORMATION USE ATTACHMENT 28 PAGE 1 OF 2 TABLE 1-14: DOSE FACTOR TABLE: R (I) - ADULT, MEAT TABLE 1-14 DOSE FACTOR TABLE: R (i) - Adult, meat Units are m2*mrem/yr per pCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+00 2.01E+02 2.01E+02 C-14 3.33E+05 6.66E+04 6.66E+04 NA-24 1.39E-03 1.39E-03 1.39E-03 P-32 4.41E+09 2.74E+08 1.71E+08 CR-51 O.OOE+00 O.OOE+00 6.30E+03 MN-54 O.OOE+00 7.24E+06 1.38E+06 MN-56 O.OOE+00 O.OOE+00 O.OOE+00 FE-55 2.28E+08 1.58E+08 3.68E+07 FE-59 2.28E+08 5.36E+08 2.05E+08 CO-57 O.OOE+00 O.OOE+00 O.OOE+00 CO-58 O.OOE+00 1.52E+07 3.40E+07 CO-60 O.OOE+00 5.84E+07 1.29E+08 NI-63 1.46E+10 1.O1E+09 4.90E+08 NI-65 O.OOE+00 O.OOE+00 O.OOE+00 CU-64 O.OOE+00 2.79E-07 1.31E-07 ZN-65 2.82E+08 8.97E+08 4.05E+08 ZN-69 O.OOE+00 O.OOE+00 O.OOE+00 ZN-69M O.OOE+00 O.OOE+00 O.OOE+00 BR-82 O.OOE+00 O.OOE+00 O.OOE+00 BR-83 O.OOE+00 O.OOE+00 O.OOE+00 BR-84 O.OOE+00 O.OOE+00 O.OOE+00 BR-85 O.OOE+00 O.OOE+00 O.OOE+00 RB-86 O.OOE+00 4.51E+08 2.10E+08 RB-88 O.OOE+00 O.OOE+00 O.OOE+00

.RB-89 O.OOE+00 O.OOE+00 O.OOE+00 SR-89 2.56E+08 O.OOE+00 7.36E+06 SR-90 9.63E+09 O.OOE+00 2.36E+09 SR-91 1.58E-10 O.OOE+00 6.39E-12 SR-92 O.OOE+00 O.OOE+00 O.OOE+00 Y-90 1.08E+02 O.OOE+00 2.90E+00 Y-91M O.OOE+00 O.OOE+00 O.OOE+00 Y-91 9.53E+05 O.OOE+00 2.55E+04 Y-92 O.OOE+00 O.OOE+00 O.OOE+00 Y-93 4.87E-12 O.OOE+00 1.35E-13 ZR-95 1.57E+06 5.02E+05 3.40E+05 ZR-97 2.1 1E-05 4.27E-06 1.95E-06 NB-95 2.01E+06 1.12E+06 6.01E+05 NB-97 O.OOE+00 O.OOE+00 O.OOE+00 MO-99 O.OOE+00 1.OIE+05 1.91E+04 TC-99M 4.74E-21 1.34E-20 1.71E-19 TC-101 O.OOE+00 O.OOE+00 O.OOE+00 RU-103 9.12E+07 O.OOE+00 3.93E+07 RU-105 6.30E-28 O.OOE+00 2.49E-28 RU-106 2.20E+09 O.OOE+00 2.78E+08 AG-1 IOM 5.29E+06 4.89E+06 2.91E+06 SB-124 O.OOE+00 O.OOE+00 O.OOE+00 SB-125 O.OOE+00 O.OOE+00 O.OOE+00 TE-125M 3.02E+08 1.09E+08 4.05E+07 TE-127M 9.07E+08 3.24E+08 1.IOE+08 TE-127 2.21E-10 7.94E-11 4.78E-1 I TE-129M 9.96E+08 3.72E+08 1.58E+08 TE-129 O.OOE+00 O.OOE+00 O.OOE+00 2.01E+02 6.66E+04 1.39E-03 O.OOE+00 3.76E+03 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 9.09E+07 2.32E+08 1.64E-10 3.42E+08 O.OOE+00 2.01E+02 2.01E+02 6.66E+04 6.66E+04 1.39E-03 1.39E-03 O.OOE+00 O.OOE+00 1.39E+03 8.36E+03 2.15E+06 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 8.80E+07 O.OOE+00 1.50E+08 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 7.03E-07 O.OOE+00 6.OOE+08 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 7.88E+05 O.OOE+00 6.44E-06 O.OOE+00 1.1 1E+06 O.OOE+00 O.OOE+00 O.OOE+00 2.28E+05 O.OOE+00 2.04E-19 6.57E-21 O.OOE+00 O.OOE+00 3.48E+08 O.OOE+00 8.14E-27 O.OOE+00 4.25E+09 O.OOE+00 9.62E+06 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 1.23E+09 O.OOE+00 3.68E+09 O.OOE+00 9.01E-10 O.OOE+00 4.16E+09 O.OOE+00 O.OOE+00 O.OOE+00 2.01E+02 6.66E+04 1.39E-03 4.96E+08 1.58E+06 2.22E+07 O.OOE+00 9.05E+07 1.79E+09 O.OOE+00 3.07E+08 1.IOE+09 2.1 1E+08 O.OOE+00 2.38E-05 5.65E+08 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 8.90E+07 O.OOE+00 O.OOE+00 4.1 1E+07 2.78E+08 7.53E-10 O.OOE+00 1.15E+06 O.OOE+OO 5.24E+08 O.OOE+OO 1.55E-07 1.59E+09 1.32E+OO 6.79E+09 O.OOE+OO 2.33E+05 7.93E-18 O.OOE+OO 1.06E+10 3.85E-25 1.42E+I I 2.OOE+09 O.OOE+OO O.OOE+OO 1.21E+09 3.04E+09 1.74E-08 5.02E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RSP-0008 REV -13 PAGE 87 OF 104

w INFORMATION USE ATTACHMENT 28 PAGE 2 OF 2 TABLE I-14: DOSE FACTOR TABLE: R (I) - ADULT, MEAT Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 4.57E+02 2.23E+02 TE-131 O.OOE+00 O.OOE+00 TE-132 1.43E+06 9.22E+05 1-130 2.18E-06 6.42E-06 1-131 1.06E+07 1.51E+07 1-132 O.OOE+00 0.OOE+00 I-133 3.72E-01 6.47E-01 1-134 O.OOE+00 O.OOE+00 1-135 4.69E-17 1.23E-16 CS-134 5.13E+08 1.22E+09 CS-136 1.15E+07 4.54E+07 CS-137 6.75E+08 9.23E+08 CS-138 O.OOE+00 O.OOE+00 BA-139 O.OOE+00 O.OOE+00 BA-140 2.75E+07 3.45E+04 BA-141 O.OOE+00 O.OOE+00 BA-142 O.OOE+00 O.OOE+00 LA-140 3.74E-02 1.89E-02 LA-142 O.OOE+00 O.OOE+00 CE-141 1.24E+04 8.37E+03 CE-143 2.03E-02 1.50E+01 CE-144 1.15E+06 4.81E+05 PR-143 2.OOE+04 8.OOE+03 PR-144 O.OOE+00 O.OOE+00 ND-147 6.84E+03 7.90E+03 W-187 2.08E-02 1.74E-02 NP-239 2.61E-01 2.56E-02 1.86E+02 0.OOE+00 8.66E+05 2.53E-06 8.66E+06 O.OOE+00 1.97E-01 0.OOE+O0 4.53E-17 9.98E+08 3.27E+07 6.05E+08 0.OOE+O0 0.OOE+O0 1.801E+06 0.OOE+O0 0.OOE+O0 4.98E-03 O.OOE+00 9.49E+02 1.66E-03 6.18E+04 9.89E+02 0.OOE+00 4.73E+02 6.09E-03 1.41E-02 3.54E+02 2.26E+03 O.OOE+00 O.OOE+00 1.02E+06 8.88E+06 5.44E-04 1.OOE-05 4.95E+09 2.59E+07 O.OOE+00 O.OOE+00 9.51E+01 1.13E+00 O.OOE+00 O.OOE+00 8.10E-15 1.97E-16 O.OOE+00 3.95E+08 O.OOE+00 2.53E+07 O.OOE+00 3.13E+08 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 1.17E+04 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3.89E+03 O.OOE+00 6.61E-03 O.OOE+00 2.85E+05 O.OOE+00 4.62E+03 O.OOE+00 O.OOE+00 O.OOE+00 4.62E+03 O.OOE+00 O.OOE+00 O.OOE+00 8.OOE+02 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE3+00 0.OOE+00 1.3 1E+08 3.46E+06 1.04E+08 0.OOE+O0 0.OOE+00 1.98E+04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE3+00 O.OOE+00 2.22E+04 O.OOE+00 4.36E+07 5.52E-06 3.991E+06 0.OOE3+00 5.82E-01 0.OOE+O0 1.39E-16 2.14E+07 5.16E+06 1.79E+07 O.OOE+00 O.OOE+00 5.66E+07 0.OOE+00 0.OOE+00 1.38E+03 0.OOE+00 3.20E+07 5.61E+02 3.89E+08 8.74E+07 O.OOE+00 3.79E+07 5.70E+00 5.26E+03 0.OOE+O0 0.OOE+O0 0.OOE+00 0.OOE3+00 0.OOE+O0 0.OOE+O0 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+O0 0.OOE+O0 0.OOE+00 0.OOE+O0 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+O0 RSP-0008 REV-13 PAGE 88 OF 104

w INFORMATION USE ATTACHMENT 29 PAGE 1 OF 2 TABLE 1-15: DOSE FACTOR TABLE: R (1) - TEEN, MEAT TABLE 1-15 DOSE FACTOR TABLE: R (i) - Teen, meat Units are m2*mrem/yr per gCi/sec

,Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+00 1.20E+02 1.20E+02 1.20E+02 1.20E+02 1.20E+02 1.20E+02 O.OOE+00 C-14 2.81E+05 5.62E+04 5.62E+04 5.62E+04 5.62E+04 5.62E+04 5.62E+04 O.OOE+00 NA-24 1.11E-03 1.11E-03 1.11E-03 I.IIE-03 1.11E-03 1.I1E-03 1.11E-03 O.OOE+00 P-32 3.73E+09 2.31E+08 1.45E+08 O.OOE+00 O.OOE+00 O.OOE+00 3.13E+08 O.OOE+00 CR-51 O.OOE+00 O.OOE+00 5.04E+03 2.80E+03 1.10E+03 7.19E+03 8.46E+05 O.OOE+00 MN-54 O.OOE+00 5.52E+06 1.09E+06 O.OOE+00 1.65E+06 O.OOE+00 1.13E+07 O.OOE+00 MN-56 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 FE-55 1.85E+08 1.31E+08 3.07E+07 O.OOE+00 O.OOE+00 8.34E+07 5.69E+07 O.OOE+00 FE-59 1.82E+08 4.25E+08 1.64E+08 O.OOE+00 O.OOE+00 1.34E+08 1.O1E+09 O.OOE+OO CO-57 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 CO-58 O.OOE+00 1.17E+07 2.69E+07 O.OOE+00 O.OOE+00 O.OOE+00 1.61E+08 O.OOE+00 CO-60 O.OOE+00 4.53E+07 1.02E+08 O.OOE+00 O.OOE+00 O.OOE+00 5.90E+08 O.OOE+OO NI-63 1.18E+10 8.30E+08 3.98E+08 O.OOE+00 O.OOE+00 O.OOE+00 1.32E+08 O.OOE+00 NI-65 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 CU-64 O.OOE+00 2.28E-07 1.07E-07 O.OOE+00 5.76E-07 O.OOE+00 1.77E-05 O.OOE+00 ZN-65 1.98E+08 6.88E+08 3.21E+08 O.OOE+00 4.40E+08 O.OOE+00 2.91E+08 O.OOE+00 ZN-69 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 ZN-69M O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 BR-82 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO BR-83 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 BR-84 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 BR-85 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RB-86 O.OOE+00 3.77E+08 1.77E+08 O.OOE+00 O.OOE+00 O.OOE+00 5.57E+07 O.OOE+00 RB-88 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RB-89 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 SR-89 2.16E+08 0.00E+00 6.20E+,06 O.OOE+00 O.OOE+00 O.OOE+00 2.58E+07 O.OOE+00 SR-90 6.23E+09 O.OOE+00 1.54E+09 O.OOE+00 O.OOE+00 O.OOE+00 1.75E+08 O.OOE+00 SR-91 1.33E-10 O.OOE+00 5.29E-12 O.OOE+00 O.OOE+00 O.OOE+00 6.30E-10 O.OOE+00 SR-92 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-90 9.11E+01 O.OOE+00 2.45E+00 O.OOE+00 O.OOE+00 O.OOE+00 7.51E+05 O.OOE+00 Y-91M O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-91 8.03E+05 O.OOE+00 2.15E+04 O.OOE+00 O.OOE+00 O.OOE+00 3.29E+08 O.OOE+00 Y-92 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Y-93 4.11E-12 0.00E+00 1.13E-13 O.OOE+00 O.OOE+O0 O.OOE+00 1.26E-07 O.OOE+00 ZR-95 1.25E+06 3.96E+05 2.72E+05 O.OOE+00 5.82E+05 O.OOE+00 9.13E+08 O.OOE+00 ZR-97 L.76E-05 3.49E-06 1.61E-06 O.OOE+OO S.29E-06 O.OOE+OO 9.44E-O1 O.OOE+OO NB-95 1.57E+06 8.71E+05 4.79E+05 O.OOE+00 8.44E+05 O.OOE+00 3.72E+09 O.OOE+00 NB-97 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 MO-99 O.OOE+00 8.31E+04 1.58E+04 O.OOE+00 1.90E+05 O.OOE+00 1.49E+05 O.OOE+00 TC-99M 3.77E-21 1.05E-20 1.36E-19 O.OOE+00 1.57E-19 5.83E-21 6.90E-18 O.OOE+00 TC-1O1 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RU-103 7.43E+07 O.OOE+00 3.17E+07 O.OOE+00 2.62E+08 O.OOE+00 6.20E+09 O.OOE+00 RU-105 S.27E-28 O.OOE+00 2.04E-28 O.OOE+00 6.65E-27 O.OOE+00 4.25E-25 O.OOE+00 RU-106 1.85E+09 O.OOE+00 2.34E+08 O.OOE+00 3.57E+09 O.OOE+00 8.89E+10 O.OOE+00 AG-llOM 4.OOE+06 3.79E+06 2.31E+06 O.OOE+00 7.23E+06 O.OOE+00 1.06E+09 O.OOE+00 SB-124 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 SB-125 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 TE-125M 2.55E+08 9.19E+07 3.41E+07 7.13E+07 O.OOE+00 O.OOE+00 7.53E+08 O.OOE+00 TE-127M 7.65E+08 2.71E+08 9.10E+07 1.82E+08 3.10E+09 O.OOE+00 1.91E+09 O.OOE+00 TE-127 1.88E-10 6.65E-11 4.04E-11 1.29E-10 7.60E-10 O.OOE+00 1.45E-08 O.OOE+00 TE-129M 8.34E+08 3.10E+08 1.32E+08 2.69E+08 3.49E+09 O.OOE+00 3.13E+09 O.OOE+00 TE-129 O.OOE+00 OOOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RSP-0008 REV-13 PAGE 89 OF 104

INFORMATION USE ATTACHMENT 29 PAGE 2 OF 2 TABLE 1-15: DOSE FACTOR TABLE: R (I) - TEEN, MEAT Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M TE-131 TE-132 I-130 I-131 1-132 1-133 1-134 1-135 CS-134 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 W-187 NP-239 3.81E+02 O.OOE+00 1.17E+06 1.75E-06 8.78E+06 O.OOE+00 3.11E-01 O.OOE+00 3.82E-17 4.08E+08 8.97E+06 5.60E+08 O.OOE+00 O.OOE+00 2.27E+07 O.OOE+00 O.OOE+00 3.08E-02 O.OOE+00 1.04E+04 1.71E-02 9.70E+05 1.68E+04 O.OOE+00 6.02E+03 1.74E-02 2.28E-01 1.83E+02 0.OOE+00 7.39E+05 5.07E-06 1.23E+07 0.OOE+O0 5.28E-01 0.OOE+O0 9.82E-17 9.60E+08 3.53E+07 7.46E+08 0.OOE+00 0.OOE+00 2.78E+04 0.OOE+00 0.OOE+00 1.5 1E-02 0.OOE+00 6.94E+03 1.24E+01 4.01E+05 6.70E+03 0.OOE+00 6.55E+03 1.42E-02 2.15E-02 1.52E+02 0.OOE+00 6.95E+05 2.02E-06 6.60E+06 0.OOE+00 1.61E-01 0.OOE+O0 3.64E-17 4.45E+08 2.37E+07 2.60E+08 0.OOE+00 0.OOE+00 1.46E+06 0.OOE+00 0.OOE+00 4.02E-03 0.OOE+00 7.97E+02 1.39E-03 5.21E+04 8.36E+02 0.OOE+00 3.92E+02 4.98E-03 1.19E-02 2.75E+02 0.OOE+00 7.79E+05 4.13E-04 3.59E+09 0.OOE+00 7.37E+01 0.OOE+00 6.32E-15 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1.90E+03 0.OOE+O0 7.09E+06 7.80E-06 2.12E+07 0.OOE+O0 9.26E-01 0.OOE+O0 1.55E-16 3.05E+08 1.92E+07 2.54E+08 0.OOE+O0 0.OOE+00 9.44E+03 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.27E+03 5.58E-03 2.40E+05 3.90E+03 0.OOE+00 3.85E+03 0.OOE+00 6.75E-02 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 1.16E+08 3.03E+06 9.86E+07 O.OOE+00 O.OOE+00 1.87E+04 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 1.47E+04 O.OOE+00 2.34E+07 3.89E-06 2.43E+06 O.OOE+00 3.99E-01 O.OOE+00 1.09E-16 1.19E+07 2.84E+06 1.06E+07 O.OOE+00 O.OOE+00 3.50E+07 O.OOE+00 O.OOE+00 8.69E+02 O.OOE+00 1.98E+07 3.74E+02 2.44E+08 5.52E+07 O.OOE+00 2.36E+07 3.85E+00 3.46E+03 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 RSP-0008 REV-13 PAGE 90 OF 104

Kl INFORMATION USE ATTACHMENT 30 PAGE 1 OF 2 TABLE 1-16: DOSE FACTOR TABLE: R (1) - CHILD, MEAT TABLE I-16 DOSE FACTOR TABLE: R (i) - Child, meat Units are m2*mrem/yr per gjCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 1.45E+02 1.45E+02 1.45E+02 1.45E+02 1.45E+02 1.45E+02 O.OOE+OO C-14 5.29E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 O.OOE+OO NA-24 1.77E-03 1.77E-03 1.77E-03 1.77E-03 1.77E-03 1.77E-03 1.77E-03 O.OOE+OO P-32 7.03E+09 3.29E+08 2.71E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.94E+08 O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 7.85E+03 4.36E+03 1.19E+03 7.96E+03 4.16E+05 O.OOE+OO MN-54 O.OOE+OO 6.31E+06 1.68E+06 O.OOE+OO 1.77E+06 O.OOE+OO 5.30E+06 O.OOE+OO MN-56 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO FE-55 3.56E+08 1.89E+08 5.85E+07 O.OOE+OO O.OOE+OO 1.07E+08 3.50E+07 O.OOE+OO FE-59 3.23E+08 5.23E+08 2.60E+08 O.OOE+OO O.OOE+OO 1.51E+08 5.44E+08 O.OOE+OO CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 1.36E+07 4.18E+07 O.OOE+OO O.OOE+OO O.OOE+OO 7.96E+07 O.OOE+OO CO-60 O.OOE+OO 5.38E+07 1.59E+08 O.OOE+OO O.OOE+OO O.OOE+OO 2.98E+08 O.OOE+OO NI-63 2.25E+10 1.21E+09 7.66E+08 O.OOE+OO O.OOE+OO O.OOE+OO 8.13E+07 O.OOE+OO NI-65 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CU-64 O.OOE+OO 3.06E-07 1.85E-07 O.OOE+OO 7.39E-07 O.OOE+OO 1.44E-05 O.OOE+OO ZN-65 2.97E+08 7.92E+08 4.93E+08 O.OOE+OO 4.99E+08 O.OOE+OO 1.39E+08 O.OOE+OO ZN-69 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 5.34E+08 3.28E+08 O.OOE+OO O.OOE+OO O.OOE+OO 3.44E+07 O.OOE+OO RB-88 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-89 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SR-89 4.10E+08 O.OOE+OO 1.17E+07 O.OOE+OO O.OOE+OO O.OOE+OO 1.59E+07 O.OOE+OO SR-90 8.05E+09 O.OOE+OO 2.04E+09 O.OOE+OO O.OOE+OO O.OOE+OO 1.08E+08 O.OOE+OO SR-91 2.50E-10 O.OOE+OO 9.42E-12 O.OOE+OO O.OOE+OO O.OOE+OO 5.51E-10 O.OOE+OO SR-92 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Y-90 1.72E+02 O.OOE+OO 4.61E+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.91E+05 O.OOE+OO Y-91M O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Y-91 1.52E+06 O.OOE+OO 4.05E+04 O.OOE+OO O.OOE+OO O.OOE+OO 2.02E+08 O.OOE+OO Y-92 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO Y-93 7.73E-12 O.OOE+OO 2.12E-13 O.OOE+OO O.OOE+OO O.OOE+OO 1.15E-07 O.OOE+OO ZR-95 2.23E+06 4.90E+05 4.36E+05 O.OOE+OO 7.01E+05 O.OOE+OO 5.1 1E+08 O.OOE+OO ZR-97 3.28E-05 4.74E-06 2.80E-06 O.OOE+00 6.80E-06 O.OOE+00 7.18E-01 O.OOE+00 NB-95 2.71E+06 1.06E+06 7.54E+05 O.OOE+OO 9.92E+05 O.OOE+OO 1.95E+09 O.OOE+OO NB-97 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO MO-99 O.OOE+OO 1.16E+05 2.86E+04 O.OOE+OO 2.47E+05 O.OOE+OO 9.56E+04 O.OOE+OO TC-99M 6.61E-21 1.30E-20 2.15E-19 O.OOE+OO 1.88E-19 6.58E-21 7.37E-18 O.OOE+OO TC-101 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RU-103 1.34E+08 O.OOE+OO 5.16E+07 O.OOE+OO 3.38E+08 O.OOE+OO 3.47E+09 O.OOE+OO RU-105 9.83E-28 O.OOE+OO 3.57E-28 O.OOE+OO 8.64E-27 O.OOE+OO 6.42E-25 O.OOE+OO RU-106 3.49E+09 O.OOE+OO 4.35E+08 O.OOE+OO 4.71E+09 O.OOE+OO 5.43E+10 O.OOE+OO AG-I IOM 6.64E+06 4.49E+06 3.59E+06 O.OOE+OO 8.36E+06 O.OOE+OO 5.34E+08 O.OOE+OO SB-124 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 4.79E+08 1.30E+08 6.39E+07 1.34E+08 O.OOE+OO O.OOE+OO 4.62E+08 O.OOE+OO TE-127M 1.44E+09 3.88E+08 1.71E+08 3.45E+08 4.11E+09 O.OOE+OO 1.17E+09 O.OOE+OO TE-127 3.53E-10 9.51E-11 7.57E-11 2.44E-10 1.OOE-09 O.OOE+OO 1.38E-08 O.OOE+OO TE-129M 1.57E+09 4.39E+08 2.44E+08 5.07E+08 4.62E+09 O.OOE+OO 1.92E+09 O.OOE+OO TE-129 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RSP-0008 REV-13 PAGE 91 OF 104

INFORMATION USE ATTACHMENT 30 PAGE 2 OF 2 TABLE 1-16: DOSE FACTOR TABLE: R (I) - CHILD, MEAT Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 7.09E+02 TE-131 O.OOE+00 TE-132 2.13E+06 1-130 3.13E-06 1-131 1.63E+07 I-132 0.OOE+00 1-133 5.78E-01 1-134 O.OOE+00 I-135 6.91E-17 CS-134 7.19E+08 CS-136 1.55E+07 CS-137 1.03E+09 CS-138 O.OOE+00 BA-139 0.OOE+00 BA-140 4.19E+07 BA-141 0.OOE+00 BA-142 O.OOE+00 LA-140 5.64E-02 LA-142 O.OOE+00 CE-141 1.96E+04 CE-143 3.21E-02 CE-144 1.83E+06 PR-143 3.18E+04 PR-144 O.OOE+00 ND-147 1.13E+04 W-187 3.23E-02 NP-239 4.29E-01 2.45E+02 0.OOE3+00 9.43E3+05 6.33E3-06 1.64E3+07 0.OO3+O00 7.15E3-01 0.OOE+00 1.24E-16 1.18E3+09 4.25E+07 9.88E3+08 O.OOE+00 0.OO3+O00 3.671E+04 O.OOE1+00 0.OOE+00 1.971E-02 O.OOE+00 9.76E+03 1.74E3+01 5.73E3+05 9.54E+03 O.OOE+00 9.161E+03 1.91E-02 3.08E-02 2.61E+02 5.04E+02 0.OOE+00 O.OOE+00 1.14E+06 1.37E+06 3.26E-06 6.97E-04 9.30E+06 5.41E+09 O.OOE+00 O.OOE+00 2.70E-01 1.33E+02 O.OOE+00 0.OOE+00 5.88E-17 1.10E-14 2.49E+08 O.OOE+00 2.75E+07 O.OOE+00 1.46E+08 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2.45E+06 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6.64E-03 O.OOE+00 O.OOE+00 O.OOE+00 1.45E+03 O.OOE+00 2.52E-03 O.OOE+00 9.76E+04 O.OOE+00 1.58E+03 0.OOE+00 O.OOE+00 O.OOE+00 7.09E+02 O.OOE+00 8.59E-03 O.OOE+00 2.16E-02 O.OOE+00 2.37E+03 0.OOE+00 8.75E+06 9.461E-06 2.691E+07 0.OOE+O0 1.191E+00 0.OOE+00 1.911E-16 3.661E+08 2.27E+07 3.22E+08 0.OOE1+00 0.OOE3+00 1.20E3+04 0.OOE3+00 0.OOE3+00 O.OOE1+00 0.OO1+O00 4.281E+03 7.29E-03

3. 17E+05
5. 171+03 0.OOE+00 5.02E+03 0.OOE+00 8.901E-02 0.OOE+O0 O.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 1.3 1E+08 3.38E+06
1. 16E+08 O.OOE+00 0.OOE+00
2. 19E+04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 9.94E+03 0.OOE+00 9.49E+06 2.96E-06 1.46E+06 O.OOE+00 2.88E-01 O.OOE+00 9.47E-17 6.36E+06 1.50E+06 6.19E+06 O.OOE+00 0.OOE+00 2.12E+07 O.OOE+00 0.OOE+00 5.49E+02 O.OOE+00 1.22E+07 2.55E+02 1.49E+08 3.43E+07 O.OOE+00 1.45E+07 2.69E+00 2.28E+03 0.OOE3+00 0.OOE+00 O.OO1+O00 0.OOE+00 0.OOE+00 O.OOE+O0 0.OOE3+00 0.OOE+00 0.OO3+O00 O.OOE+O0 0.OOE+O0 O.OOE3+00 O.OO3+O00 0.OOE1+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE3+00 0.OO3+O00 0.OOE3+00 0.OOE3+00 0.OOE3+00 0.OOE3+00 O.OOE3+00 O.OO3+O00 0.OOE+00 0.OOE3+00 RSP-0008 REV-13 PAGE 92 OF 104

m INFORMATION USE ATTACHMENT 31 PAGE 1 F F2 TABLE 1-17: DOSE FACTOR TABLE: R (I) - ADULT, VEGETATION TABLE I-17 DOSE FACTOR TABLE: R (i)- Adult, vegetation Units are m2*mrem/yr per pCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 1.40E+03 1.40E+03 1.40E+03 1.40E+03 1.40E+03 C-14 8.97E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 1.79E+05 NA-24 2.68E+05 2.68E+05 2.68E+05 2.68E+05 2.68E+05 2.68E+05 P-32 1.40E+09 8.72E+07 5.42E+07 O.OOE+OO O.OOE+OO O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 4.64E+04 2.77E+04 1.02E+04 6.15E+04 MN-54 O.OOE+OO 3.10E+08 5.92E+07 O.OOE+OO 9.23E+07 O.OOE+OO MN-56 O.OOE+OO 1.54E+01 2.74E+OO O.OOE+OO 1.96E+O1 O.OOE+OO FE-55 2.08E+08 1.43E+08 3.34E+07 O.OOE+OO O.OOE+OO 8.OOE+07 FE-59 1.26E+08 2.96E+08 1.13E+08 O.OOE+OO O.OOE+OO 8.26E+07 CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 3.06E+07 6.86E+07 O.OOE+OO O.OOE+OO O.OOE+OO CO-60 O.OOE+OO 1.65E+08 3.65E+08 O.OOE+OO O.OOE+OO O.OOE+OO NI-63 1.03E+10 7.14E+08 3.45E+08 O.OOE+OO O.OOE+OO O.OOE+OO NI-65 5.96E+01 7.75E+00 3.54E+OO O.OOE+OO O.OOE+OO O.OOE+OO CU-64 O.OOE+OO 9.14E+03 4.29E+03 O.OOE+OO 2.31E+04 O.OOE+OO ZN-65 3.15E+08 1.OOE+09 4.53E+08 O.OOE+OO 6.70E+08 O.OOE+OO ZN-69 5.06E-06 9.67E-06 6.72E-07 O.OOE+OO 6.28E-06 O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 3.01E+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 2.14E-11 O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 2.19E+08 1.02E+08 O.OOE+OO O.OOE+OO O.OOE+OO RB-88 O.OOE+OO 2.64E-22 1.40E-22 O.OOE+OO O.OOE+OO O.OOE+OO RB-89 O.OOE+OO 2.88E-26 2.03E-26 O.OOE+OO O.OOE+OO O.OOE+OO SR-89 9.94E+09 O.OOE+OO 2.85E+08 O.OOE+OO O.OOE+OO O.OOE+OO SR-90 S.98E+1 1 O.OOE+OO 1.47E+1 I O.OOE+OO O.OOE+OO O.OOE+OO SR-91 3.02E+05 O.OOE+OO 1.22E+04 O.OOE+OO O.OOE+OO O.OOE+OO SR-92 4.15E+02 O.OOE+OO 1.79E+01 O.OOE+OO O.OOE+OO O.OOE+OO Y-90 1.33E+04 O.OOE+OO 3.56E+02 O.OOE+OO O.OOE+OO O.OOE+OO Y-91M 4.76M-09 O.OOE+OO 1.84E-10 O.OOE+OO O.OOE+OO O.OOE+OO Y-91 5.09E+06 O.OOE+OO 1.36E+05 O.OOE+OO O.OOE+OO O.OOE+OO Y-92 8.96E-O1 O.OOE+OO 2.62E-02 O.OOE+OO O.OOE+OO O.OOE+OO Y-93 1.68E+02 O.OOE+OO 4.65E+OO O.OOE+OO O.OOE+OO O.OOE+OO ZR-95 1.17E+06 3.75E+05 2.54E+05 O.OOE+OO 5.89E+05 O.OOE+OO ZR-97 3.36E+02 6.78E+01 3.10E+O1 O.OOE+OO 1.02E+02 O.OOE+OO NB-95 1.42E+05 7.90E+04 4.25E+04 O.OOE+OO 7,81E+04 O.OOE+OO NB-97 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO MO-99 O.OOE+OO 6.14E+06 1.17E+06 O.OOE+OO 1.39E+07 O.OOE+OO TC-99M 3.06E+00 8.66E+OO 1.10E+02 O.OOE+OO 1.31E+02 4.24E+OO TC-101 5.93E-31 8.55E-31 8.39E-30 O.OOE+OO 1.54E-29 4.37E-31 RU-103 4.76E+06 O.OOE+OO 2.05E+06 O.OOE+OO 1.82E+07 O.OOE+OO RU-105 5.29E+01 O.OOE+OO 2.09E+O1 O.OOE+OO 6.84E+02 O.OOE+OO RU-106 1.91E+08 O.OOE+OO 2.42E+07 O.OOE+OO 3.69E+08 O.OOE+OO AG-I IOM 1.05E+07 9.67E+06 5.74E+06 O.OOE+OO 1.90E+07 O.OOE+OO SB-124 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 9.62E+07 3.49E+07 1.29E+07 2.89E+07 3.91E+08 O.OOE+OO TE-127M 3.47E+08 1.24E+08 4.23E+07 8.87E+07 1.41E+09 O.OOE+OO TE-127 5.61E+03 2.02E+03 1.21E+03 4.16E+03 2.29E+04 O.OOE+OO TE-129M 2.51E+08 9.36E+07 3.97E+07 8.61E+07 1.05E+09 O.OOE+OO TE-129 7.13E-04 2.68E-04 1.74E-04 5.48E-04 3.OOE-03 O.OOE+OO 1.40E+03 O.OOE+OO 1.79E+05 O.OOE+OO 2.68E+05 O.OOE+OO 1.58E+08 O.OOE+OO 1.17E+07 O.OOE+OO 9.SOE+08 O.OOE+OO 4.92E+02 O.OOE+OO 8.23E+07 O.OOE+OO 9.85E+08 O.OOE+OO O.OOE+OO O.OOE+OO 6.20E+08 O.OOE+OO 3.1 1E+09 O.OOE+OO 1.49E+08 O.OOE+OO 1.97E+02 O.OOE+OO 7.79E+05 O.OOE+OO 6.3 lE+08 O.OOE+OO 1.45E-06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.33E+OO O.OOE+OO 1.68E-16 O.OOE+OO O.OOE+OO O.OOE+OO 4.32E+07 O.OOE+OO 3.65E-33 O.OOE+OO O.OOE+OO O.OOE+OO 1.59E+09 O.OOE+OO 1.73E+10 O.OOE+OO 1.44E+06 O.OOE+OO 8.21E+03 O.OOE+OO 1.41E+08 O.OOE+OO 1.40E-08 O.OOE+OO 2.80E+09 O.OOE+OO 1.57E+04 O.OOE+OO 5.34E+06 O.OOE+OO 1.19E+09 O.OOE+OO 2.10E+07 O.OOE+OO 4.80E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.42E+07 O.OOE+OO 5.12E+03 O.OOE+OO O.OOE+OO O.OOE+OO 5.56E+08 O.OOE+OO 3.24E+04 O.OOE+OO 1.24E+10 O.OOE+OO 3.95E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.84E+08 O.OOE+OO 1.16E+09 O.OOE+OO 4.43E+05 O.OOE+OO 1.26E+09 O.OOE+OO 5.38E-04 O.OOE+OO RSP-0008 REV-13 PAGE 93 OF 104

/

INFORMATION USE ATTACHMENT 31 PAGE2 OF2 TABLE 1-17: DOSE FACTOR TABLE: R (I) - ADULT, VEGETATION Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 9.10E+05 4.45E+05 3.71E+05 7.05E+05 4.51E+06 TE-131 1.25E-15 5.21E-16 3.94E-16 1.03E-15 5.47E-15 TE-132 4.30E+06 2.78E+06 2.61E+06 3.07E+06 2.68E+07 1-130 3.90E+05 1.15E+06 4.54E+05 9.75E+07 1.79E+06 1-131 8.07E+07 1.15E+08 6.61E+07 3.78E+10 1.98E+08 I-132 5.57E+01 1.49E+02 5.21E+01 5.21E+03 2.37E+02 1-133 2.08E+06 3.61E+06 1.10E+06 5.31E+08 6.31E+06 I-134 8.84E-05 2.40E-04 8.59E-05 4.16E-03 3.82E-04 I-135 3.85E+04 1.01E+05 3.72E+04 6.65E+06 1.62E+05 CS-134 4.62E+09 1.10E+10 8.99E+09 O.OOE+00 3.56E+09 CS-136 4.26E+07 1.68E+08 1.21E+08 O.OOE+00 9.37E+07 CS-137 6.29E+09 8.61E+09 5.64E+09 O.OOE+00 2.92E+09 CS-138 3.39E-11 6.70E-11 3.32E-11 O.OOE+00 4.92E-11 BA-139 2.70E-02 1.92E-05 7.91E-04 O.OOE+00 1.80E-05 BA-140 1.28E+08 1.61E+05 8.41E+06 O.OOE+00 5.48E+04 BA-141 8.94E-22 6.76E-25 3.02E-23 O.OOE+00 6.28E-25 BA-142 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LA-140 1.97E+03 9.95E+02 2.63E+02 O.OOE+00 O.OOE+00 LA-142 1.92E-04 8.75E-05 2.18E-05 O.OOE+00 O.OOE+00 CE-141 1.97E+05 1.33E+05 1.51E+04 O.OOE+00 6.18E+04 CE-143 9.95E+02 7.36E+05 8.14E+01 O.OOE+00 3.24E+02 CE-144 3.26E+07 1.36E+07 1.75E+06 O.OOE+00 8.09E+06 PR-143 6.25E+04 2.51E+04 3.10E+03 O.OOE+00 1.45E+04 PR-144 2.36E-26 9.81E-27 1.20E-27 O.OOE+00 5.53E-27 ND-147 3.33E+04 3.85E+04 2.30E+03 O.OOE+00 2.25E+04 W-187 3.79E+04 3.17E+04 1.11E+04 O.OOE+00 O.OOE+00 NP-239 1.43E+03 1.40E+02 7.73E+01 O.OOE+00 4.37E+02 O.OOE+00 4.42E+07 O.OOE+00 1.77E-16 O.OOE+00 1.31E+08 O.OOE+00 9.90E+05 O.OOE+00 3.04E+07 O.OOE+00 2.80E+01 O.OOE+00 3.25E+06 O.OOE+00 2.09E-07 O.OOE+00 1.14E+05 1.18E+09 1.92E+08 1.28E+07 1.91E+07 9.71E+08 1.67E+08 4.86E-12 2.86E-16 1.09E-05 4.79E-02 9.23E+04 2.64E+08 3.83E-25 4.21E-31 O.OOE+00 O.OOE+00 O.OOE+00 7.30E+07 O.OOE+00 6.39E-01 O.OOE+00 5.09E+08 O.OOE+00 2.75E+07 O.OOE+00 1.10E+10 O.OOE+00 2.74E+08 O.OOE+00 3.40E-33 O.OOE+00 1.85E+08 O.OOE+00 1.04E+07 O.OOE+00 2.88E+07 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 RSP-0008 REV-13 PAGE 94 OF 104

ww

INFORMATICIN USE ATTACHMENT 32 PAGE 1 OF 2 TABLE 1-18: DOSE FACTOR TABLE: R (I) - TEEN, VEGETATION TABLE 1-18 DOSE FACTOR TABLE: R (i)- Teen, vegetation Units are m2*mrem/vr per.Cilsec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+OO 1.60E+03 1.60E+03 1.60E+03 1.60E+03 1.60E+03 1.60E+03 O.OOE+OO C-14 1.45E+06 2.91E+05 2.91E+05 2.91E+05 2.91E+05 2.91E+05 2.91E+05 O.OOE+OO NA-24 2.38E+05 2.38E+05 2.38E+05 2.38E+05 2.38E+05 2.38E+05 2.38E+05 O.OOE+OO P-32 1.61E+09 9.95E+07 6.23E+07 O.OOE+OO O.OOE+OO O.OOE+OO 1.35E+08 O.OOE+OO CR-51 O.OOE+OO O.OOE+OO 6.16E+04 3.42E+04 1.35E+04 8.79E+04 1.03E+07 O.OOE+OO MN-54 O.OOE+OO 4.51E+08 8.94E+07 O.OOE+OO 1.34E+08 O.OOE+OO 9.24E+08 O.OOE+OO MN-56 O.OOE+OO 1.39E+01 2.47E+OO O.OOE+OO 1.76E+O1 O.OOE+OO 9.16E+02 O.OOE+OO FE-55 3.23E+08 2.29E+08 5.34E+07 O.OOE+OO O.OOE+OO 1.45E+08 9.90E+07 O.OOE+OO FE-59 1.79E+08 4.17E+08 1.61E+08 O.OOE+OO O.OOE+OO 1.32E+08 9.87E+08 O.OOE+OO CO-57 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CO-58 O.OOE+OO 4.34E+07 1.OOE+08 O.OOE+OO O.OOE+OO O.OOE+OO 5.98E+08 O.OOE+OO CO-60 O.OOE+OO 2.46E+08 5.54E+08 O.OOE+OO O.OOE+OO O.OOE+OO 3.21E+09 O.OOE+OO NI-63 1.59E+10 1.12E+09 5.39E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.79E+08 O.OOE+OO NI-65 5.55E+01 7.09E+00 3.23E+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.85E+02 O.OOE+OO CU-64 O.OOE+OO 8.28E+03 3.90E+03 O.OOE+OO 2.10E+04 O.OOE+OO 6.43E+05 O.OOE+OO ZN-65 4.20E+08 1.46E+09 6.81E+08 O.OOE+OO 9.34E+08 O.OOE+OO 6.18E+08 O.OOE+OO ZN-69 4.73E-06 9.02E-06 6.31E-07 O.OOE+OO 5.89E-06 O.OOE+OO 1.66E-05 O.OOE+OO ZN-69M O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 2.82E+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 O.OOE+OO O.OOE+OO 1.95E-1 1 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-85 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO RB-86 O.OOE+OO 2.73E+08 1.28E+08 O.OOE+OO O.OOE+OO O.OOE+OO 4.04E+07 O.OOE+OO RB-88 O.OOE+OO 2.44E-22 1.30E-22 O.OOE+OO O.OOE+OO O.OOE+OO 2.09E-29 O.OOE+OO RB-89 O.OOE+OO 2.59E-26 1.83E-26 O.OOE+OO O.OOE+OO O.OOE+OO 3.98E-05 O.OOE+OO SR-89 1.51E+10 O.OOE+OO 4.32E+08 O.OOE+OO O.OOE+OO O.OOE+OO 1.80E+09 O.OOE+OO SR-90 7.43E+ll O.OOE+OO 1.84E+ll O.OOE+OO O.OOE+OO O.OOE+OO 2.09E+10 O.OOE+OO SR-91 2.82E+05 O.OOE+OO 1.12E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.28E+06 O.OOE+OO SR-92 3.86E+02 O.OOE+OO 1.65E+O1 O.OOE+OO O.OOE+OO O.OOE+OO 9.83E+03 O.OOE+OO Y-90 1.24E+04 O.OOE+OO 3.34E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.02E+08 O.OOE+OO Y-91M 4.43E-09 O.OOE+OO 1.69E-10 O.OOE+OO O.OOE+OO O.OOE+OO 2.09E-07 O.OOE+OO Y-91 7.81E+06 O.OOE+OO 2.09E+05 O.OOE+OO O.OOE+OO O.OOE+OO 3.20E+09 O.OOE+OO Y-92 8.42E-O1 O.OOE+OO 2.43E-02 O.OOE+OO O.OOE+OO O.OOE+OO 2.31E+04 O.OOE+OO Y-93 1.58E+02 O.OOE+OO 4.33E+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.82E+06 O.OOE+OO ZR-95 1.71E+06 5.41E+05 3.72E+05 O.OOE+OO 7.95E+05 O.OOE+OO 1.25E+09 O.OOE+OO ZR-97 3.11E+02 6.15E+01 2.83E+01 O.OOE+00 9.33E+01 O.OOE+00 1.67E+07 O.OOE+00 NB-95 1.92E+05 1.06E+O5 5.86E+04 O.OOE+OO 1.03E+O5 O.OOE+OO 4.55E+08 O.OOE+OO NB-97 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO MO-99 O.OOE+OO 5.64E+06 1.08E+06 O.OOE+OO 1.29E+07 O.OOE+OO 1.OIE+07 O.OOE+OO TC-99M 2.70E+00 7.54E+00 9.77E+O1 O.OOE+OO 1.12E+02 4.18E+00 4.95E+03 O.OOE+OO TC-101 5.52E-31 7.85E-31 7.71E-30 O.OOE+OO 1.42E-29 4.78E-31 1.34E-37 O.OOE+OO RU-103 6.80E+06 O.OOE+OO 2.91E+06 O.OOE+OO 2.40E+07 O.OOE+OO 5.68E+08 O.OOE+OO RU-105 4.92E+O1 O.OOE+OO 1.91E+O1 O.OOE+OO 6.20E+02 O.OOE+OO 3.97E+04 O.OOE+OO RU-106 3.07E+08 O.OOE+OO 3.87E+07 O.OOE+OO 5.92E+08 O.OOE+OO 1.47E+10 O.OOE+OO AG-I IOM 1.50E+07 1.42E+07 8.65E+06 O.OOE+OO 2.71E+07 O.OOE+OO 4.OOE+09 O.OOE+OO SB-124 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SB-125 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TE-125M 1.48E+08 5.32E+07 1.97E+07 4.13E+07 O.OOE+OO O.OOE+OO 4.36E+08 O.OOE+OO TE-127M S.48E+08 1.94E+08 6.52E+07 1.30E+08 2.22E+09 O.OOE+OO 1.37E+09 O.OOE+OO TE-127 5.29E+03 1.88E+03 1.14E+03 3.65E+03 2.14E+04 O.OOE+OO 4.09E+O5 O.OOE+OO TE-129M 3.61E+08 1.34E+08 5.71E+07 1.16E+08 1.51E+09 O.OOE+OO 1.35E+09 O.OOE+OO TE-129 6.68E-04 2.49E-04 1.63E-04 4.77E-04 2.80E-03 O.OOE+OO 3.65E-03 O.OOE+OO RSP-0008 REV-13 PAGE 95 OF 104

INFORMATION USE ATTACHMENT 32 PAGE 2 OF 2 TABLE I-18: DOSE FACTOR TABLE: R (I) - TEEN, VEGETATION Nuclide Bone Liver Tbody Thyroid Kidney Lune GI Tract Skin TE-131M 8.42E+05 4.04E+05 3.37E+05 6.07E+05 4.21E+06 O.OOE+00 3.24E+07 O.OOE+00 TE-131 1.16E-15 4.78E-16 3.62E-16 8.93E-16 5.07E-15 O.OOE+00 9.52E-17 O.OOE+00 TE-132 3.90E+06 2.47E+06 2.33E+06 2.61E+06 2.37E+07 O.OOE+00 7.83E+07 O.OOE+00 1-130 3.49E+05 1.01E+06 4.03E+05 8.22E+07 1.55E+06 O.OOE+00 7.75E+05 O.OOE+00 I-131 7.67E+07 1.07E+08 5.77E+07 3.14E+10 1.85E+08 O.OOE+00 2.13E+07 O.OOE+00 I-132 5.02E+01 1.31E+02 4.72E+01 4.43E+03 2.07E+02 O.OOE+00 5.72E+01 O.OOE+00 1-133 1.93E+06 3.27E+06 9.99E+05 4.57E+08 5.74E+06 O.OOE+00 2.48E+06 O.OOE+00 I-134 7.99E-05 2.12E-04 7.61E-05 3.53E-03 3.34E-04 O.OOE+00 2.79E-06 O.OOE+00 I-135 3.48E+04 8.96E+04 3.32E+04 5.76E+06 1.42E+05 O.OOE+00 9.93E+04 O.OOE+00 CS-134 7.03E+09 1.66E+10 7.68E+09 O.OOE+00 5.26E+09 2.01E+09 2.06E+08 O.OOE+00 CS-136 4.37E+07 1.72E+08 1.15E+08 O.OOE+00 9.36E+07 1.47E+07 1.38E+07 O.OOE+00 CS-137 1.OOE+10 1.33E+10 4.65E+09 O.OOE+00 4.54E+09 1.76E+09 1.90E+08 0.OOE+00 CS-138 3.13E-11 6.01E-11 3.OOE-11 O.OOE+00 4.44E-11 5.16E-12 2.73E-14 O.OOE+00 BA-139 2.54E-02 1.79E-05 7.40E-04 O.OOE+00 1.69E-05 1.23E-05 2.27E-01 O.OOE+00 BA-140 1.38E+08 1.69E+05 8.89E+06 O.OOE+00 5.73E+04 1.14E+05 2.13E+08 O.OOE+00 BA-141 8.36E-22 6.24E-25 2.79E-23 O.OOE+00 5.79E-25 4.27E-25 1.78E-27 O.OOE+00 BA-142 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 LA-140 1.80E+03 8.86E+02 2.36E+02 O.OOE+00 O.OOE+00 O.OOE+00 5.09E+07 O.OOE+00 LA-142 1.77E-04 7.84E-05 1.95E-05 O.OOE+00 O.OOE+00 O.OOE+00 2.39E+00 O.OOE+00 CE-141 2.82E+05 1.89E+05 2.17E+04 O.OOE+00 8.87E+04 O.OOE+00 5.39E+08 O.OOE+00 CE-143 9.30E+02 6.77E+05 7.56E+01 O.OOE+00 3.04E+02 O.OOE+00 2.04E+07 O.OOE+00 CE-144 5.23E+07 2.16E+07 2.81E+06 O.OOE+00 1.29E+07 O.OOE+00 1.32E+10 0.OOE+00 PR-143 6.99E+04 2.79E+04 3.48E+03 O.OOE+00 1.62E+04 O.OOE+00 2.30E+08 O.OOE+00 PR-144 2.22E-26 9.07E-27 1.12E-27 O.OOE+00 5.20E-27 O.OOE+00 2.44E-29 O.OOE+00 ND-147 3.62E+04 3.93E+04 2.36E+03 O.OOE+00 2.31E+04 O.OOE+00 1.42E+08 O.OOE+00 W-187 3.52E+04 2.87E+04 1.01E+04 O.OOE+00 O.OOE+00 O.OOE+00 7.77E+06 O.OOE+00 NP-239 1.38E+03 1.31E+02 7.25E+01 O.OOE+00 4.10E+02 O.OOE+00 2.10E+07 O.OOE+00 RSP-0008 REV-13 PAGE 96 OF 104

N INFORMATION USE ATTACHMENT 33 PAGE 1 OF 2 TABLE 1-19: DOSE FACTOR TABLE: R (I) - CHILD, VEGETATION TABLE 1-19 DOSE FACTOR TABLE: R (i)- Child, vegetation Units are m2*mrem/yr per pCi/sec Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin H-3 O.OOE+00 C-14 3.50E+06 NA-24 3.71E+05 P-32 3.36E+09 CR-51 O.OOE+00 MN-54 O.OOE+00 MN-56 O.OOE+00 FE-55 7.94E+08 FE-59 3.96E+08 CO-57 O.OOE+00 CO-58 O.OOE+00 CO-60 O.OOE+00 NI-63 3.91E+10 NI-65 1.02E+02 CU-64 O.OOE+00 ZN-65 8.06E+08 ZN-69 8.73E-06 ZN-69M O.OOE+00 BR-82 O.OOE+00 BR-83 O.OOE+00 BR-84 O.OOE+00 BR-85 O.OOE+00 RB-86 O.OOE+00 RB-88 O.OOE+00 RB-89 O.OOE+00 SR-89 3.58E+10 SR-90 1.23E+12 SR-91 5.20E+05 SR-92 7.07E+02 Y-90 2.30E+04 Y-91M 8.12E-09 Y-91 1.86E+07 Y-92 1.55E+00 Y-93 2.91E+02 ZR-95 3.84E+06 ZR-97 5.68E+02 NB-95 4.09E+05 NB-97 O.OOE+00 MO-99 O.OOE+00 TC-99M 4.65E+00 TC-101 1.02E-30 RU-103 1.53E+07 RU-105 9.01E+01 RU-106 7.39E+08 AG-IIOM 3.19E+07 SB-124 O.OOE+00 2.49E+03 7.01E+05 3.71E+05 1.57E+08 O.OOE+00 6.59E+08 1.82E+01 4.21E+08 6.41E+08 0.00E+00 6.41E+07 3.75E+08 2.09E+09 9.59E+00 1.09E+04 2.15E+09 1.26E-05 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+O0 4.51E+08 3.77E-22 3.42E-26 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 8.44E+05 8.20E+01 1.59E+05 O.OOE+00 7.70E+06 9.12E+00 1.06E-30 0.OOE+00 0.00E+Q0 0.OOE+00

2. 15E+07 0.OOE+00 2.49E+03 7.01E+05 3.71E+05 1.30E+08 1.17E+05 1.76E+08 4.1 1E+00 1.30E+08 3.19E+08 0.OOE+00 1.96E+08 1.10E+09 1.33E+09 5.60E+00 6.60E+03 1.34E+09 1.17E-06 0.OOE+00 0.OOE+00 5.20E+00 3.30E-1 1 0.OOE+00 2.78E+08 2.34E-22 3.04E-26 1.02E+09
3. 12E+1 I1 1.96E+04 2.84E+01 6.17E+02 2.95E-10 4.97E+05 4.43E-02 7.98E+00 7.52E+05 4.84E+01 1.14E+05 O.OOE+00 1.91E+06 1.5 1E+02 1.35E-29 5.88E+06 3.27E+01 9.22E+07 1.72E+07 O.OOE+00 2.49E+03 2.49E+03 7.01E+05 7.01E+05 3.71E+05 3.71E+05 O.OOE+00 O.OOE+00 6.49E+04 1.77E+04 O.OOE+00 1.85E+08 O.OOE+00 2.20E+01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2.64E+04 O.OOE+00 1.35E+09 O.OOE+00 7.66E-06 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 1.21E+06 0.OOE+00
1. 18E+02 O.OOE+00 1.50E+05 0.OOE+00 O.OOE+00 O.OOE+00 1.64E+07 O.OOE+00 1.32E+02 O.OOE+00 1.81E-29 O.OOE+00 3.85E+07 O.OOE+00 7.92E+02 O.OOE+00 9.98E+08 O.OOE+00 4.01E+07 O.OOE+00 O.OOE+00 2.49E+03 7.01E+05 3.71E+05 0.OOE+00 1.18E+05 0.OOE+00 0.OOE+00 2.38E+08 1.86E+08 O.OOE+O0 O.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+O0 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 O.OOE+00 0.OOE+00 4.63E+00 5.62E-3 1 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 2.49E+03 7.0 1E+05 3.71E+05 9.30e+07 6.20E+06 5.53E+08 2.64E+03 7.80E+07 6.68E+08 0.OOE+00 3.74E+08 2.07E+09 1.41E+08
1. 17E+03 5.13E+05 3.77E+08 7.96E-04 0.OOE+00 0.OOE+00 0.OOE+O0 O.OOE+00 0.OOE+00 2.90E+07 1.65E-23 2.98E-28 1.39E+09 1.66E+10 1.15E+06 1.34E+04 6.56E+07 1.59E-05 2.47E+09 4.48E+04 4.34E+06 8.81E+08 1.24E+07 2.95E+08 0.OOE+00 6.37E+06 5.19E+03 3.38E-30 3.95E+08 5.88E+04 1.15E+10 2.56E+09 0.OE+O00 0.OOE+00 3.37E+08 1.06E+09 3.81E+05 1.02E+09 7.70E-02 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+O0 0.OOE-I00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 SB-125 O.OOE+00 O.OOE+00 TE-125M 3.49E+08 9.47E+07 TE-127M 1.31E+09 3.54E+08 TE-127 9.76E+03 2.63E+03 TE-129M 8.39E+08 2.34E+08 TE-129 1.24E-03 3.45E-04 O.OOE+00 O.OOE+00 O.OOE+00 4.66E+07 9.80E+07 O.OOE+00 1.56E+08 3.14E+08 3.75E+09 2.09E+03 6.76E+03 2.78E+04 1.30E+08 2.71E+08 2.46E+09 2.94E-04 8.82E-04 3.62E-03 RSP-0008 REV - 13 PAGE 97 OF 104 RSP-0008 REV-13 PAGE97OF1O4

wmp

INFORMATION USE ATTACHMENT 33 PAGE 2 OF 2 TABLE 1-19: DOSE FACTOR TABLE: R (I) - CHILD, VEGETATION Nuclide Bone Liver Tbody Thyroid Kidney Lung GI Tract Skin TE-131M 1.54E+06 5.32E+05 5.66E+05 1.09E+06 5.15E+06 TE-131 2.14E-15 6.51E-16 6.35E-16 1.63E-15 6.46E-15 TE-132 6.99E+06 3.10E+06 3.74E+06 4.51E+06 2.87E+07 1-130 6.12E+05 1.24E+06 6.37E+05 1.36E+08 1.85E+06 1-131 1.43E+08 1.44E+08 8.16E+07 4.75E+10 2.36E+08 1-132 8.91E+01 1.64E+02 7.53E+01 7.60E+03 2.51E+02 1-133 3.52E+06 4.35E+06 1.65E+06 8.08E+08 7.25E+06 1-134 1.42E-04 2.64E-04 1.21E-04 6.07E-03 4.03E-04 1-135 6.18E+04 1.11E+05 5.26E+04 9.86E+06 1.71E+05 CS-134 1.59E+10 2.61E+10 5.50E+09 O.OOE+OO 8.08E+09 CS-136 8.23E+07 2.26E+08 1.46E+08 O.OOE+O0 1.20E+08 CS-137 2.37E+10 2.27E+10 3.35E+09 O.OOE+00 7.39E+09 CS-138 5.69E-11 7.91E-11 5.02E-11 O.OOE+00 5.57E-1l BA-139 4.69E-02 2.50E-05 1.36E-03 O.OOE+0O 2.18E-05 BA-140 2.76E+08 2.42E+05 1.60E+07 O.OOE+00 7.88E+04 BA-141 1.54E-21 8.64E-25 5.02E-23 O.OOE+O0 7.47E-25 BA-142 O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 LA-140 3.24E+03 1.13E+03 3.82E+02 O.OOE+00 O.OOE+OO LA-142 3.20E-04 1.02E-04 3.19E-05 O.OOE+00 O.OOE+00 CE-141 6.55E+05 3.26E+05 4.85E+04 O.OOE+0O 1.43E+05 CE-143 1.71E+03 9.29E+05 1.35E+02 O.OOE+00 3.90E+02 CE-144 1.26E+08 3.95E+07 6.73E+06 O.OOE+O0 2.19E+07 PR-143 1.45E+05 4.36E+04 7.21E+03 O.OOE+00 2.36E+04 PR-144 4.11E-26 1.27E-26 2.07E-27 O.OOE+00 6.73E-27 ND-147 7.14E+04 S.78E+04 4.48E+03 O.OOE+00 2.17E+04 W-187 6.41E+04 3.79E+04 1.70E+04 O.OOE+00 O.OOE+OO NP-239 2.56E+03 1.83E+02 1.29E+02 O.OOE+00 5.31E+02 0.OO1+O00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OO1+O00 0.OOE+00 0.OOE+00 2.90E+09 1.80E+07 2.66E+09 5.99E-12 1.47E-05 1.44E+05 5.07E-24 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 2.16E+07 O.OOE+00 1.12E-14 O.OOE+00 3.12E+07 O.OOE+00 5.78E+05 O.OOE+00 1.28E+07 O.OOE+00 1.93E+02 O.OOE+00 1.75E+06 O.OOE+00 1.75E-04 O.OOE+00 8.48E+04 0.OOE+00 1.41E+08 0.OOE+00 7.95E+06 O.OOE+O0 1.42E+08 O.OOE+O0 3.64E-1 1 O.OOE+00 2.70E+00 0.OOE+00 1.40E+08 O.OOE+00 8.79E-22 O.OOE+00 0.OOE+O0 O.OOE+00 3.16E+07 O.OOE+00 2.02E+O1 0.OOE+00 4.07E+08 O.OOE+00 1.36E+07 0.OOE+0O 1.03E+10 O.OOE+O0 1.57E+08 O.OOE+00 2.74E-23 O.OOE+0O 9.16E+07 O.OOE+O0 5.33E+06 O.OOE+O0 1.36E+07 O.OOE+00 RSP-0008 REV-13 PAGE 98 OF 104

INFORMATION USE ATTACHMENT 34 PAGE 1 OF I FIGURE 1: RESTRICTED AREA AND NEAR-FIELD ENVIRONMENTAL MONITORING LOCATIONS I

H (SSE)



FIGURE 1 

jflIwaI Envtrmentn Locaflona A I ArSampr i"

T TI T d-I wu Weu-I WD ' 6pk WWII-6;gad O@31

'Onat Garme, X

RISP-0008 REV - 13 PAGE 99 OF 104 R4P-flOflS REV-13 PAGE9QOF1O4

INFORMATION USE ATTACHMENT 35 PAGE 1 OF I FIGURE 2: SCHEMATIC OF GASEOUS RADWASTE SYSTEM RSP-0008 REV-13 PAGE 100 OF 104

I omoV 0 o IC 2-j;

\\T METERS FE"EI

-~

00 200 OO 45 50

FOR INFORMATION ONLY-NOTA PERMANENT RECORD

~Anion, Cabion~,

wat 3

sineraelzrs C

(4!()

a 4)Equipm~ent Dmains Anion, Caton, Rstcovery t:1

/

_ Flter > 4 Mixed bed Smi WC tDemeinrerm Ss Tlnud e

~Floor Dreins o:

Floor l3 Demnins in (4)

Coniden series Rcl TTanks (3)

(2)

Rpdnafero B

~RWWU Fiter/Demin Sludge Se for colMonirtor 1"ar ks Tak r71 e

Condensste ackws Wafste otare a

RecycleW o

.(1)

(2)

SldeRadiabion RE 107 o

Condenate Demin Resin Redwaste Demin Resin Fuel Pool Demin Mississippi Fuel Pool Filter Slurry Rer T3 Radwaste Fitter Slurry Tower l z Blowdown Line Radiation Monitor RE 108 lj

\\

INFORMATION USE ATTACHMENT 38 PAGE I OF I FIGURE 5: FAR-FIELD RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS

,I1.

" ay i

C I (14E?

-/

It I'

/

/

/

e I- :

D 1 (ENE) j.

d:_ *Ff' l

  1. 4 (w)

M

(WSw)

E z CE)

S.

N 1 (EseI I 4

/),

/

,}

/f

-j

.I -

I I I1, I11 I>

II Sw) i-

-c', -,

4# 

X

- 4  ; ,, - -Ajtv-

.. A It AII1 IIA1

FIGUBE5

,, I vst-Attdjwdlo f 6"

dwift AC Air Sampler Control A S Air Sampler Special T I TLD Indicators T-C TLD Controls TS Special TLDs GQC Vegetation Control SWU Upstream SufiLce Water SWD Downstream Surfice Water SEDD Downstream Sediment FU Upstream Fish/Invertebrates FD Downstream Fish/Invertebrates I

I I

I I

I

. A:RaS

-~,

i...,f I-

- S E...

I I-I' I

E.'

1i kN N.

' ' 4

',"i,

.S ~

~

z I,

I q

's

,i "S.

'r 7>$

, E.i..>..1 RSP-0008 REV - 13 PAGE 103 OF 104

_ S -0 0 REV -1 PA G 10 OF 104

-*N INFORMATION USE ATTACHMENT 39 PAGE 1 OF 1 FIGURE 6: SCHEMATIC OF THE SOLID WASTE TREATMENT SYSTEM 1 Nue Pool Denin Spent Kfns 17GPD Permanent hi Portable ()

I Radwaste Auto Strainer (3) 400 GPD I

Radwaste Filter Sludge 2004 GPD Fuel Pol Filter Sludga 29 GPD RW Derin Spent Resin 18GPD waste Sludge Tank To LWS System Waste Dewater (40M8BPD)

Plant Connection Stand l

I Cond Demin Spent Resin 747 GPD

)Solidlfcation)

I RWCU Fiter/ Demin Sludge 323 GPD i Decon & Lab Drains 13) 6OOGPD Compressable Waste Compactor (Not Available) 55 Gallon Drum NOTE: (1) Fblwates Include Transfer Water end Solids

2) Refer to Toical Report Cnsl-2 (431441354W0IP-For Details
13) Suspended Solids are Assumred to be Negligible, and are Not Considered RSP-0008 REV - 13 PAGE 104 OF 104 RSP- 008 E V-13 P

GE 04 O 10