BSEP 05-0110, Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors
ML052500310 | |
Person / Time | |
---|---|
Site: | Brunswick |
Issue date: | 08/31/2005 |
From: | O'Neil E Progress Energy Carolinas |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
BSEP 05-0110 | |
Download: ML052500310 (2) | |
Similar Documents at Brunswick | |
---|---|
Category:Letter type:BSEP
MONTHYEARBSEP 19-0012, Submittal of 2018 Sea Turtle Annual Report2019-01-17017 January 2019
[Table view]Submittal of 2018 Sea Turtle Annual Report BSEP 18-0052, Annual Radiological Environmental Operating Report - 20172018-05-10010 May 2018 Annual Radiological Environmental Operating Report - 2017 BSEP 18-0051, Annual Radioactive Effluent Release Report - 20172018-04-26026 April 2018 Annual Radioactive Effluent Release Report - 2017 BSEP 18-0045, Request for License Amendment: Technical Specification 3.8.3, Diesel Fuel Oil, One-Time Extension of Main Fuel Oil Storage Tank Completion Time2018-04-25025 April 2018 Request for License Amendment: Technical Specification 3.8.3, Diesel Fuel Oil, One-Time Extension of Main Fuel Oil Storage Tank Completion Time BSEP 18-0054, Response to Request for Additional Information Regarding Inservice Inspection Program Proposed Alternative ISI-09 in Accordance with 10 CFR 50.55a(z)(1) Regarding Reactor Pressure Vessel Circumferential.2018-04-24024 April 2018 Response to Request for Additional Information Regarding Inservice Inspection Program Proposed Alternative ISI-09 in Accordance with 10 CFR 50.55a(z)(1) Regarding Reactor Pressure Vessel Circumferential. BSEP 18-0048, Response to Request for Additional Information Regarding Inservice Inspection Program Proposed Alternative ISI-09 in Accordance with 10 CFR 50.55a(z)(1) Regarding Reactor Pressure Vessel Circumferential Shell Weld Examinations2018-04-11011 April 2018 Response to Request for Additional Information Regarding Inservice Inspection Program Proposed Alternative ISI-09 in Accordance with 10 CFR 50.55a(z)(1) Regarding Reactor Pressure Vessel Circumferential Shell Weld Examinations BSEP 18-0044, Application of Dissimilar Metal Weld Full Structural Overlay - Reactor Pressure Vessel Nozzles N4A and N4D2018-04-11011 April 2018 Application of Dissimilar Metal Weld Full Structural Overlay - Reactor Pressure Vessel Nozzles N4A and N4D BSEP 18-0046, Supplement to Response to Request for Additional Information SRXB-RAI-2 Regarding Request for License Amendment Regarding Core Flow Operating Range Expansion2018-04-10010 April 2018 Supplement to Response to Request for Additional Information SRXB-RAI-2 Regarding Request for License Amendment Regarding Core Flow Operating Range Expansion BSEP 18-0047, Supplement to Proposed Alternative in Accordance with 10 CFR 50.55a(z)(2) for End of Interval Leakage Test2018-04-0505 April 2018 Supplement to Proposed Alternative in Accordance with 10 CFR 50.55a(z)(2) for End of Interval Leakage Test BSEP 18-0041, Request for License Amendment to Revise the Technical Specifications to Relocate the Pressure-Temperature Limit Curves to a Pressure and Temperature Limits Report2018-04-0404 April 2018 Request for License Amendment to Revise the Technical Specifications to Relocate the Pressure-Temperature Limit Curves to a Pressure and Temperature Limits Report BSEP 18-0043, Application of Dissimilar Metal Weld Full Structural Overlay - Reactor Pressure Vessel Nozzles N4A and N4D2018-03-31031 March 2018 Application of Dissimilar Metal Weld Full Structural Overlay - Reactor Pressure Vessel Nozzles N4A and N4D BSEP 18-0035, Response to Request for Additional Information Regarding Request for License Amendment Regarding Core Flow Operating Range Expansion2018-03-29029 March 2018 Response to Request for Additional Information Regarding Request for License Amendment Regarding Core Flow Operating Range Expansion BSEP 18-0042, Cycle 22 Core Operating Limits Report (COLR)2018-03-27027 March 2018 Cycle 22 Core Operating Limits Report (COLR) BSEP 18-0040, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) for End of Interval Leakage Test2018-03-23023 March 2018 Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) for End of Interval Leakage Test BSEP 18-0039, Proposed In-Service Inspection Alternative for Application of Dissimilar Metal Weld Full Structural Overlay - Nozzles N4A and N4D2018-03-19019 March 2018 Proposed In-Service Inspection Alternative for Application of Dissimilar Metal Weld Full Structural Overlay - Nozzles N4A and N4D BSEP 18-0034, Corrected Affidavit Relating to the Request for License Amendment Regarding Core Flow Operating Range Expansion2018-03-16016 March 2018 Corrected Affidavit Relating to the Request for License Amendment Regarding Core Flow Operating Range Expansion BSEP 18-0032, Additional Testing Information Relating to the Request for License Amendment Regarding Core Flow Operating Range Expansion2018-03-14014 March 2018 Additional Testing Information Relating to the Request for License Amendment Regarding Core Flow Operating Range Expansion BSEP 18-0026, Additional Information Regarding Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) for Reactor Pressure Vessel Nozzle-to-Vessel Weld Examination2018-03-0707 March 2018 Additional Information Regarding Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) for Reactor Pressure Vessel Nozzle-to-Vessel Weld Examination BSEP 18-0014, Fifth 10-Year Inservice Testing Program Plan2018-02-19019 February 2018 Fifth 10-Year Inservice Testing Program Plan BSEP 18-0021, Response to Request for Additional Information Regarding Request for License Amendment Regarding Core Flow Operating Range Expansion (CAC Nos. MF8864 and MF8865). Without Proprietary Enclosure2018-02-0505 February 2018 Response to Request for Additional Information Regarding Request for License Amendment Regarding Core Flow Operating Range Expansion (CAC Nos. MF8864 and MF8865). Without Proprietary Enclosure BSEP 18-0017, Revision to Radiological Emergency Response Plan and Implementing Procedure2018-01-30030 January 2018 Revision to Radiological Emergency Response Plan and Implementing Procedure BSEP 18-0015, Inservice Inspection Program Proposed Alternative ISI-09 in Accordance with 10 CFR 50.55a(z)(1) Regarding Reactor Pressure Vessel Circumferential Shell Weld Examinations2018-01-23023 January 2018 Inservice Inspection Program Proposed Alternative ISI-09 in Accordance with 10 CFR 50.55a(z)(1) Regarding Reactor Pressure Vessel Circumferential Shell Weld Examinations BSEP 18-0013, Supplement to Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control2018-01-23023 January 2018 Supplement to Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control BSEP 18-0001, Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2018-01-23023 January 2018 Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements BSEP 18-0012, Application to Revise Technical Specifications to Adopt TSTF-208, Revision 0, Extension of Time to Reach Mode 2 in LCO 3.0.32018-01-23023 January 2018 Application to Revise Technical Specifications to Adopt TSTF-208, Revision 0, Extension of Time to Reach Mode 2 in LCO 3.0.3 BSEP 18-0009, 2017 Sea Turtle Annual Report2018-01-15015 January 2018 2017 Sea Turtle Annual Report BSEP 17-0098, Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components (Sscs) for Nuclear Power Reactors2018-01-10010 January 2018 Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components (Sscs) for Nuclear Power Reactors BSEP 17-0119, Snubber Program Plan for Fifth 10-Year Interval Inservice Testing Program2018-01-10010 January 2018 Snubber Program Plan for Fifth 10-Year Interval Inservice Testing Program BSEP 17-0115, Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control2018-01-0404 January 2018 Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control BSEP 17-0110, Seventh Six-Month Status Report in Response to June 6, 2013, Commission Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions2017-12-20020 December 2017 Seventh Six-Month Status Report in Response to June 6, 2013, Commission Order Modifying Licenses with Regard to Reliable Hardened Containment Vents Capable of Operation Under Severe Accident Conditions BSEP 17-0121, Post-Examination Documentation and Comments for Operator Retake Initial Examination2017-12-14014 December 2017 Post-Examination Documentation and Comments for Operator Retake Initial Examination BSEP 17-0120, Withdrawal of Request for Risk-Informed Exigent License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel Generator Completion Times and Suspension..2017-12-12012 December 2017 Withdrawal of Request for Risk-Informed Exigent License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel Generator Completion Times and Suspension.. BSEP 17-0118, Supplement to Response to Request for Additional Information Regarding Request for Risk-Informed Exigent License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel..2017-12-0707 December 2017 Supplement to Response to Request for Additional Information Regarding Request for Risk-Informed Exigent License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel.. BSEP 17-0117, Response to Request for Additional Information (Probabilistic Risk Assessment and Human Performance Branches) Regarding Request for Risk-Informed Exigent License Amendment - Technical Specification 3.8.1 AC Sources..2017-12-0606 December 2017 Response to Request for Additional Information (Probabilistic Risk Assessment and Human Performance Branches) Regarding Request for Risk-Informed Exigent License Amendment - Technical Specification 3.8.1 AC Sources.. BSEP 17-0116, Response to Request for Additional Information Regarding Request for Risk- Informed Exigent License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of ..2017-12-0404 December 2017 Response to Request for Additional Information Regarding Request for Risk- Informed Exigent License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of .. BSEP 17-0104, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) for Reactor Pressure Vessel Nozzle-to-Vessel Weld Examination2017-11-29029 November 2017 Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) for Reactor Pressure Vessel Nozzle-to-Vessel Weld Examination BSEP 17-0111, Request for Risk-Informed Exigent License Amendment - Technical Specification 3.8.1, AC Sources Operating, One-Time Extension of Emergency Diesel Generator Completion Times and Suspension of Surveillance Requirements2017-11-28028 November 2017 Request for Risk-Informed Exigent License Amendment - Technical Specification 3.8.1, AC Sources Operating, One-Time Extension of Emergency Diesel Generator Completion Times and Suspension of Surveillance Requirements BSEP 17-0109, Response to Request for Additional Information Regarding Request for Emergency License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel Generator Completion Times And.2017-11-24024 November 2017 Response to Request for Additional Information Regarding Request for Emergency License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel Generator Completion Times And. BSEP 17-0108, Request for Emergency License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel Generator Completion Times and Suspension of Surveillance Requirements2017-11-22022 November 2017 Request for Emergency License Amendment - Technical Specification 3.8.1, AC Sources - Operating, One-Time Extension of Emergency Diesel Generator Completion Times and Suspension of Surveillance Requirements BSEP 17-0017, Submittal of Request for License Amendment for Performance-Based Fire Protection Alternative for Thermal Insulation Material2017-11-15015 November 2017 Submittal of Request for License Amendment for Performance-Based Fire Protection Alternative for Thermal Insulation Material BSEP 17-0100, Fifth 10-Year Inservice Testing Interval2017-11-0202 November 2017 Fifth 10-Year Inservice Testing Interval BSEP 17-0089, Updates to Request for License Amendment Regarding Core Flow Operating Range Expansion2017-11-0101 November 2017 Updates to Request for License Amendment Regarding Core Flow Operating Range Expansion BSEP 17-0093, Response to Request for Additional Information Regarding Request for License Amendment Regarding Core Flow Operating Range Expansion2017-11-0101 November 2017 Response to Request for Additional Information Regarding Request for License Amendment Regarding Core Flow Operating Range Expansion BSEP 17-0078, Request for License Amendment - DC Sources - Operating Surveillance Requirement (SR) 3.8.4.52017-10-0303 October 2017 Request for License Amendment - DC Sources - Operating Surveillance Requirement (SR) 3.8.4.5 BSEP 17-0076, Registration for Use of General License Spent Fuel Casks2017-09-0606 September 2017 Registration for Use of General License Spent Fuel Casks BSEP 17-0081, Revision to Radiological Emergency Response Plan Implementing Procedures2017-09-0505 September 2017 Revision to Radiological Emergency Response Plan Implementing Procedures BSEP 17-0039, Submittal of Response to Inspection Report 05000324/2015404 and 05000325/2015404, Dated March 30, 2015, Inspection of Interim Cyber Security Milestones 1-7 and Target Set Requirements2017-08-15015 August 2017 Submittal of Response to Inspection Report 05000324/2015404 and 05000325/2015404, Dated March 30, 2015, Inspection of Interim Cyber Security Milestones 1-7 and Target Set Requirements BSEP 17-0071, ISFSI - Registration for Use of General License Spent Fuel Casks2017-08-15015 August 2017 ISFSI - Registration for Use of General License Spent Fuel Casks BSEP 17-0064, Application of Dissimilar Metal Weld Full Structural Overlay on Reactor Pressure Vessel Nozzle N92017-07-10010 July 2017 Application of Dissimilar Metal Weld Full Structural Overlay on Reactor Pressure Vessel Nozzle N9 BSEP 17-0060, Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control.2017-06-29029 June 2017 Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control. 2019-01-17 Category:Report MONTHYEARML24047A2092024-02-22022 February 2024
[Table view]Calendar Year 2023 Baseline Inspection Completion RA-22-0165, Inservice Inspection Program Owner'S Activity Report for Refueling Outage 242022-06-0909 June 2022 Inservice Inspection Program Owner'S Activity Report for Refueling Outage 24 RA-22-0134, Unit 1 Cycle 23 Mellla+ Eigenvalue Tracking Data2022-05-25025 May 2022 Unit 1 Cycle 23 Mellla+ Eigenvalue Tracking Data RA-21-0198, Inservice Inspection Program Owner'S Activity Report for Refueling Outage 252021-06-21021 June 2021 Inservice Inspection Program Owner'S Activity Report for Refueling Outage 25 RA-21-0176, Cycle 24 Mellla+ Eigenvalue Tracking Data2021-06-0707 June 2021 Cycle 24 Mellla+ Eigenvalue Tracking Data RA-20-0353, Proposed Alternative to ASME Boiler & Pressure Vessel Code Section XI Requirements for Repair/Replacement of Service Water (SW) System Buried Piping in Accordance with 10 CFR 50.55a(z)(1)2021-02-24024 February 2021 Proposed Alternative to ASME Boiler & Pressure Vessel Code Section XI Requirements for Repair/Replacement of Service Water (SW) System Buried Piping in Accordance with 10 CFR 50.55a(z)(1) RA-20-0347, 10 CFR 71.95 Report on the 3-60B Cask2020-11-16016 November 2020 10 CFR 71.95 Report on the 3-60B Cask RA-19-0479, Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies2019-12-31031 December 2019 Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies RA-19-0411, Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies2019-10-23023 October 2019 Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies RA-19-0338, Pressure and Temperature Limits Report for Unit Nos. 1 and 22019-08-15015 August 2019 Pressure and Temperature Limits Report for Unit Nos. 1 and 2 RA-19-0243, Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies2019-07-0202 July 2019 Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies RA-19-0223, Annual Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models Pursuant to 10CFR 50.462019-05-30030 May 2019 Annual Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models Pursuant to 10CFR 50.46 RA-19-0240, Response to Request for Additional Information Regarding Advanced Framatome Methodologies License Amendment Request2019-05-29029 May 2019 Response to Request for Additional Information Regarding Advanced Framatome Methodologies License Amendment Request RA-19-0139, Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies2019-03-18018 March 2019 Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies RA-18-0100, Request for License Amendment Regarding Application of Advanced Framatome Methodologies2018-10-11011 October 2018 Request for License Amendment Regarding Application of Advanced Framatome Methodologies RA-18-0131, Technical Requirements Manual, Revision 662018-08-13013 August 2018 Technical Requirements Manual, Revision 66 ML18249A1592018-08-13013 August 2018 Technical Requirements Manual, Revision 73 RA-18-0024, Supplemental Information to Request for License Amendment to Revise the Technical Specifications to Relocate the Pressure-Temperature Limit Curves to a Pressure and Temperature Limits Report2018-05-29029 May 2018 Supplemental Information to Request for License Amendment to Revise the Technical Specifications to Relocate the Pressure-Temperature Limit Curves to a Pressure and Temperature Limits Report BSEP 18-0044, Application of Dissimilar Metal Weld Full Structural Overlay - Reactor Pressure Vessel Nozzles N4A and N4D2018-04-11011 April 2018 Application of Dissimilar Metal Weld Full Structural Overlay - Reactor Pressure Vessel Nozzles N4A and N4D ML17024A0362016-12-31031 December 2016 Operating Data Report for 2016 ML16287A4222016-09-26026 September 2016 FS1-0028339 Revision 1.0, Brunswick, Unit 1, Cycle 21 and Unit 2 Cycle 23 MELLLA SLMCPR Analyses with SAFLIM30 Methodology. ML16223A7252016-08-17017 August 2016 Interim Staff Evaluation Relating to Overall Integrated Plan in Response to Phase 2 of Order EA-13-109 (Severe Accident Capable Hardened Events) CAC Nos. MF4467 and MF4468) ML18250A0022016-08-11011 August 2016 Technical Requirements Manual, Revision 70 ML18250A0032016-08-11011 August 2016 Technical Requirements Manual, Revision 63 ML16257A4112016-07-31031 July 2016 DUKE-0B21-1104-000(NP), Safety Analysis Report for Brunswick Steam Electric Plant, Units 1 and 2, Maximum Extended Load Line Limit Analysis Plus. ML16041A4352016-03-0101 March 2016 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50 Section 50.54(f) Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-Term Task Force ML16257A4062015-12-31031 December 2015 ANP-3106(NP), Revision 2, Brunswick Units 1 and 2 LOCA-ECCS Analysis MAPLHGR Limit for Atrium 10XM Fuel for Mellla+ Operation. ML15275A2902015-09-30030 September 2015 Areva, Inc., - ANP-3397NP, Revision 0, Brunswick, Unit 2, Atrium 11 Lead Test Assemblies Design & Licensing Summary Report. BSEP 16-0056, ANP-3108(NP), Revision 1, Applicability of Areva BWR Methods to Brunswick Extended Power Flow Operating Domain.2015-07-31031 July 2015 ANP-3108(NP), Revision 1, Applicability of Areva BWR Methods to Brunswick Extended Power Flow Operating Domain. ML16257A4082015-07-31031 July 2015 ANP-3105(NP), Revision 1, Brunswick Units 1 and 2 LOCA Break Spectrum Analysis for Atrium 10XM Fuel for Mellla+ Operation. BSEP 15-0004, Enclosure 3 - Areva Operability Assessment. (CR 2014-7395)2015-01-13013 January 2015 Enclosure 3 - Areva Operability Assessment. (CR #2014-7395) BSEP 14-0131, Expedited Seismic Evaluation Process Report in Response to 10 CFR 50.54(f) Request for Information Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident2014-12-18018 December 2014 Expedited Seismic Evaluation Process Report in Response to 10 CFR 50.54(f) Request for Information Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident ML14297A2662014-10-24024 October 2014 Record of Review, Brunswick Steam Electric Plant, Units 1 and 2, LAR Attachment U- Table U-1 Internal Events PRA Peer Review- Facts and Observations (F&Os), 10/24/14 BSEP 14-0101, Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors2014-09-0404 September 2014 Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors BSEP 14-0093, Report of 10 CFR 50.59 Evaluations and Commitment Changes2014-08-14014 August 2014 Report of 10 CFR 50.59 Evaluations and Commitment Changes ML14176A9612014-06-24024 June 2014 Submittal of Non-Proprietary BWROG Technical Product, BWROGTP-11-006 - ECCS Containment Walkdown Procedure, Rev 1 (January 2011), as Formally Requested During the Public Meeting Held on April 30, 2014 BSEP 14-0028, Seismic Hazard and Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) the Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi A2014-03-31031 March 2014 Seismic Hazard and Screening Report (CEUS Sites), Response to NRC Request for Information Pursuant to 10 CFR 50.54(f) the Seismic Aspects of Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-ichi Accid ML13220A0902013-11-22022 November 2013 Interim Staff Evaluation Regarding Overall Integrated Plan in Response to Order EA-12-049 - Mitigation Strategies ML13317A5922013-11-20020 November 2013 Mega-Tech Services, LLC Technical Evaluation Report Regarding the Overall Integrated Plan for Brunswick Steam Electric Plant, Units 1 and 2, TAC Nos.: MF0975 and MF0976 ML13277A0412013-09-19019 September 2013 Transition to 10 CFR 50.48(c) - NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants, 2001 Edition ML16257A4072013-05-31031 May 2013 ANP-3013(NP), Revision 0, Brunswick Unit 1 Cycle 19 Fuel Cycle Design Mellla+ Operating Domain. BSEP 13-0030, Overall Integrated Plan in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events2013-02-28028 February 2013 Overall Integrated Plan in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events BSEP 13-0002, Technical Data Record, 12-9197120-000, Brunswick SAFLIM3D LAR Support - Calculation Error Impact2013-01-14014 January 2013 Technical Data Record, 12-9197120-000, Brunswick SAFLIM3D LAR Support - Calculation Error Impact ML13031A0112013-01-11011 January 2013 Engineering Information Record, Document No. 51-9196989-000, Supplemental Information for Brunswick SAFLIM3D Submittal: Impact of Assemblies Outside Existing Channel Bow Fast Fluence Gradient Database BSEP 12-0127, Recommendation 2.3 Seismic Walkdown of the Near-Term Task Force Review of Insights from the Fukushima Dai-Ichi Accident2012-11-27027 November 2012 Recommendation 2.3 Seismic Walkdown of the Near-Term Task Force Review of Insights from the Fukushima Dai-Ichi Accident BSEP 12-0133, Document No. 51-9195058-000, Areva Input to Process Energy: Follow-Up to SAFLIM3D LAR Request for Additional Information 3, Enclosure 3 to BSEP 12-01332012-11-27027 November 2012 Document No. 51-9195058-000, Areva Input to Process Energy: Follow-Up to SAFLIM3D LAR Request for Additional Information 3, Enclosure 3 to BSEP 12-0133 BSEP 12-0128, Special Report - Technical Requirements Manual Section 3.4, Accident Monitoring Instrumentation2012-11-14014 November 2012 Special Report - Technical Requirements Manual Section 3.4, Accident Monitoring Instrumentation ML12321A3192012-11-0101 November 2012 1000771.402NP, Revision 2, Life Extension for Core Plate Plugs at Brunswick Nuclear Plant Unit 2. ML12065A3802012-03-26026 March 2012 Request to Reinitiate Section 7 Consultation for Atlantic Sturgeon at Brunswick Steam Electric Plant, Units 1 and 2 BSEP 12-0031, Areva Document ANP-3086(NP), Brunswick Units 1 and 2 SLMCPR Operability Assessment Critical Power Correlation for Atrium 10XM Fuel - Improved K-factor Model, Enclosure 20 to BSEP 12-00312012-02-29029 February 2012 Areva Document ANP-3086(NP), Brunswick Units 1 and 2 SLMCPR Operability Assessment Critical Power Correlation for Atrium 10XM Fuel - Improved K-factor Model, Enclosure 20 to BSEP 12-0031 2024-02-22 Category:Miscellaneous MONTHYEARML24047A2092024-02-22022 February 2024
[Table view]Calendar Year 2023 Baseline Inspection Completion RA-22-0165, Inservice Inspection Program Owner'S Activity Report for Refueling Outage 242022-06-0909 June 2022 Inservice Inspection Program Owner'S Activity Report for Refueling Outage 24 RA-21-0198, Inservice Inspection Program Owner'S Activity Report for Refueling Outage 252021-06-21021 June 2021 Inservice Inspection Program Owner'S Activity Report for Refueling Outage 25 RA-20-0353, Proposed Alternative to ASME Boiler & Pressure Vessel Code Section XI Requirements for Repair/Replacement of Service Water (SW) System Buried Piping in Accordance with 10 CFR 50.55a(z)(1)2021-02-24024 February 2021 Proposed Alternative to ASME Boiler & Pressure Vessel Code Section XI Requirements for Repair/Replacement of Service Water (SW) System Buried Piping in Accordance with 10 CFR 50.55a(z)(1) RA-19-0479, Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies2019-12-31031 December 2019 Supplement to Request for License Amendment Regarding Application of Advanced Framatome Methodologies RA-19-0223, Annual Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models Pursuant to 10CFR 50.462019-05-30030 May 2019 Annual Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models Pursuant to 10CFR 50.46 BSEP 18-0044, Application of Dissimilar Metal Weld Full Structural Overlay - Reactor Pressure Vessel Nozzles N4A and N4D2018-04-11011 April 2018 Application of Dissimilar Metal Weld Full Structural Overlay - Reactor Pressure Vessel Nozzles N4A and N4D ML17024A0362016-12-31031 December 2016 Operating Data Report for 2016 ML16223A7252016-08-17017 August 2016 Interim Staff Evaluation Relating to Overall Integrated Plan in Response to Phase 2 of Order EA-13-109 (Severe Accident Capable Hardened Events) CAC Nos. MF4467 and MF4468) ML16041A4352016-03-0101 March 2016 Staff Assessment of Information Provided Pursuant to Title 10 of the Code of Federal Regulations Part 50 Section 50.54(f) Seismic Hazard Reevaluations for Recommendation 2.1 of the Near-Term Task Force BSEP 15-0004, Enclosure 3 - Areva Operability Assessment. (CR 2014-7395)2015-01-13013 January 2015 Enclosure 3 - Areva Operability Assessment. (CR #2014-7395) BSEP 14-0131, Expedited Seismic Evaluation Process Report in Response to 10 CFR 50.54(f) Request for Information Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident2014-12-18018 December 2014 Expedited Seismic Evaluation Process Report in Response to 10 CFR 50.54(f) Request for Information Regarding Recommendation 2.1 of the Near-Term Task Force Review of Insights from the Fukushima Dai-lchi Accident ML14297A2662014-10-24024 October 2014 Record of Review, Brunswick Steam Electric Plant, Units 1 and 2, LAR Attachment U- Table U-1 Internal Events PRA Peer Review- Facts and Observations (F&Os), 10/24/14 BSEP 14-0101, Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors2014-09-0404 September 2014 Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors BSEP 14-0093, Report of 10 CFR 50.59 Evaluations and Commitment Changes2014-08-14014 August 2014 Report of 10 CFR 50.59 Evaluations and Commitment Changes ML13277A0412013-09-19019 September 2013 Transition to 10 CFR 50.48(c) - NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants, 2001 Edition BSEP 13-0030, Overall Integrated Plan in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events2013-02-28028 February 2013 Overall Integrated Plan in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events BSEP 12-0127, Recommendation 2.3 Seismic Walkdown of the Near-Term Task Force Review of Insights from the Fukushima Dai-Ichi Accident2012-11-27027 November 2012 Recommendation 2.3 Seismic Walkdown of the Near-Term Task Force Review of Insights from the Fukushima Dai-Ichi Accident BSEP 12-0128, Special Report - Technical Requirements Manual Section 3.4, Accident Monitoring Instrumentation2012-11-14014 November 2012 Special Report - Technical Requirements Manual Section 3.4, Accident Monitoring Instrumentation ML1127000692011-09-26026 September 2011 Enclosure 2, Mfn 10-245 R4, Description of the Evaluation and Surveillance Recommendations for BWR/2-5 Plants BSEP 14-0007, 1707-01-F03, Rev. 3, Operability Assessment (CR2013-8241)2011-09-0808 September 2011 1707-01-F03, Rev. 3, Operability Assessment (CR#2013-8241) BSEP 11-0038, Renewed Facility Operating License and Cycle 20 Core Operating Limits Report2011-04-0808 April 2011 Renewed Facility Operating License and Cycle 20 Core Operating Limits Report ML1108712502011-03-24024 March 2011 BWR Vessel and Internals Inspection Summaries for Spring 2010 Outages BSEP 10-0097, Report of 10 CFR 50.59 Evaluations and Commitment Changes2010-08-18018 August 2010 Report of 10 CFR 50.59 Evaluations and Commitment Changes ML1019304172010-05-0606 May 2010 Tritium Database Report ML1012704392010-05-0505 May 2010 Y020100187 - List of Historical Leaks and Spills at U.S. Commercial Nuclear Power Plants ML1019305532009-12-14014 December 2009 NEI 07-07 NEI Groundwater Protection Initiative NEI Peer Assessment Report for Brunswick BSEP 09-0022, Special Report - Technical Requirements Manual Section 3.4, Accident Monitoring Instrumentation2009-02-23023 February 2009 Special Report - Technical Requirements Manual Section 3.4, Accident Monitoring Instrumentation BSEP 08-0121, Submittal of Annual 10 CFR 50.46 Report of Emergency Core Cooling System Evaluation Model Changes and Errors2008-09-24024 September 2008 Submittal of Annual 10 CFR 50.46 Report of Emergency Core Cooling System Evaluation Model Changes and Errors ML0711000062006-12-0808 December 2006 Operational Safety Review Team (Osart) Mission and Follow-up Visit Report BSEP 06-0095, Report of 10 CFR 50.59 Evaluation and Commitment Changes2006-08-24024 August 2006 Report of 10 CFR 50.59 Evaluation and Commitment Changes BSEP 06-0075, Groundwater Questionnaire2006-07-28028 July 2006 Groundwater Questionnaire ML0614404872006-05-18018 May 2006 Submittal of 10-O Report for Quarterly Period Ending March 31, 2006 BSEP 05-0137, Core Operating Limits Report, Revision 2, Cycle 152005-11-14014 November 2005 Core Operating Limits Report, Revision 2, Cycle 15 BSEP 05-0110, Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors2005-08-31031 August 2005 Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors ML0515903332005-05-31031 May 2005 Submittal of 10-Q Report ML0535300692005-05-0909 May 2005 Operational Safety Review Team (Osart) Mission to Brunswick Nuclear Plant 9-25 May 2005 BSEP 05-0018, Occupational Radiation Exposure Report for 20042005-04-20020 April 2005 Occupational Radiation Exposure Report for 2004 ML0434301332004-11-30030 November 2004 Submital of 10-Q Report ML0414602462004-05-19019 May 2004 Q Report for Period Ending 03/31/2004 ML0324716322003-08-22022 August 2003 Submittal of 10-Q Report ML0318909362003-07-10010 July 2003 Relaxation of the Order, Exercising Enforcement Discretion, and Extension of the Time to Submit an Answer or Request a Hearing Regarding Order EA-03-038, Fitness-for-Duty Enhancements for Nuclear Security Force Personnel for Brunswick, Crys ML0317000272003-06-0606 June 2003 Submittal of 10-O Report ML19204A1621998-11-18018 November 1998 Enclosure 1 - Staff Evaluation Report of Individual Plant Examination of External Events (IPEEE) Submittal on Brunswick Steam Electric Plant (Bsep), Units 1 and 2 2024-02-22 |
Text
Progress Energy AUG 3 12005 10 CFR 50.46(a)(3)(ii)
SERIAL: BSEP05-0110 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
Subject:
Brunswick Steam Electric Plant, Unit Nos. 1 and 2 Docket Nos. 50-325 and 50-324/License Nos. DPR-71 and DPR-62 Annual Report of Emergency Core Cooling System Evaluation Model Changes and Errors
Reference:
Letter from Edward T. O'Neil to the U.S. Nuclear Regulatory Commission, "Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models," dated September 9, 2004 (ML042610122)
Ladies and Gentlemen:
In accordance with 10 CFR 50.46, "Acceptance criteria for emergency core cooling systems for light-water nuclear power reactors," paragraph (a)(3)(ii), Carolina Power &
Light Company, now doing business as Progress Energy Carolinas, Inc. (PEC), is submitting the annual report of the emergency core cooling system (ECCS) evaluation model changes and errors for the Brunswick Steam Electric Plant, Unit Nos. 1 and 2.
This report covers the period from August 11, 2004, through July 31, 2005. The previous annual report for BSEP, Units 1 and 2, was submitted by PEC's letter dated September 9, 2004. Since the last annual report, no error or change notifications have been issued by Global Nuclear Fuels affecting the ECCS evaluation model for BSEP, Units 1 and 2; f therefore, the estimated licensing basis peak cladding temperatures (PCTs) remain unchanged from the values reported in the September 9, 2004, letter (i.e., <17320 F for GE13 fuel and <15670 F for GE14 fuel).
No regulatory commitments are contained in this letter. Please refer any questions regarding this submittal to Mr. Leonard R. Beller, Supervisor - Licensing/Regulatory Programs, at (910) 457-2073.
Sincerely, Edward T. O'Neil Manager - Support Services Brunswick Steam Electric Plant Progress Energy Carolinas. Inc.
Brunswick Nuclear Plant c C)
P.O. Box 10429 Southport, NC 28461
Document Control Desk BSEP 05-0 110 / Page 2 WRM/wrm cc:
U. S. Nuclear Regulatory Commission, Region II ATTN: Dr. William D. Travers, Regional Administrator Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, GA 30303-8931 U. S. Nuclear Regulatory Commission ATTN: Mr. Eugene M. DiPaolo, NRC Senior Resident Inspector 8470 River Road Southport, NC 28461-8869 U. S. Nuclear Regulatory Commission (Electronic Copy Only)
ATTN: Ms. Brenda L. Mozafari (Mail Stop OWFN 8G9) 11555 Rockville Pike Rockville, MD 20852-2738 Ms. Jo A. Sanford Chair - North Carolina Utilities Commission P.O. Box 29510 Raleigh, NC 27626-0510