ML051150349

From kanterella
Jump to navigation Jump to search

Transmittal of Donald C. Cook, Units 1 and 2 - Copy of NRC and Plant Improved Technical Specifications Conversion Website
ML051150349
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 04/15/2005
From: Nazar M
Indiana Michigan Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
AEP:NRC:5901-02, TAC MC2629, TAC MC2630
Download: ML051150349 (4)


Text

Indiana Michigan Power INDIANA Cook Nuclear Plant MICHIGAN One Cook Place Bridgman, MI 49106 POWER' AEP.com Aunit ofAmerican Electric Powver April 15, 2005 AEP:NRC:5901-02 10 CFR 50.90 Docket Nos. 50-315 50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant, Units 1 and 2 COPY OF U. S. NUCLEAR REGULATORY COMMISSION AND DONALD C. COOK NUCLEAR PLANT IMPROVED TECHNICAL SPECIFICATIONS CONVERSION WEBSITE (TAC NOS. MC2629 AND MC2630)

References:

1. Letter from M. K. Nazar, Indiana Michigan Power Company, to Nuclear Regulatory Commission Document Control Desk, 'Donald C. Cook Nuclear Plant Unit 1 and Unit 2, License Amendment Request - Conversion of Current Technical Specifications (CTS) to Improved Technical Specifications (ITS)," AEP:NRC:4901, dated April 6, 2004.
2. Letter from J. N. Jensen, Indiana Michigan Power Company, to Nuclear Regulatory Commission Document Control Desk, "Donald C. Cook Nuclear Plant Units 1 and 2, Supplement to License Amendment Request - Conversion of Current Technical Specifications (CTS) to Improved Technical Specifications (ITS),

(TAC Nos. MC2629 and MC2630)," AEP:NRC:5901, dated April 15, 2005.

Dear Sir or Madam:

By References 1 and 2, Indiana Michigan Power Company (I&M) submitted an original and supplemental application to amend Appendix A, Technical Specifications, of Donald C. Cook Nuclear Plant (CNP) Unit 1 and Unit 2 Facility Operating Licenses DPR-58 and DPR-74, respectively, revising the current Technical Specifications (CTS) to the Improved Technical Specifications (ITS) consistent with Improved Standard Technical Specifications as described in NUREG-1431, "Standard Technical Specifications - Westinghouse Plants," Revision 2, and certain generic changes to the NUREG.

Azon

U. S. Nuclear Regulatory Commission AEP:NRC:5901-02 Page 2 The purpose of this letter is to provide a complete copy of the joint U. S. Nuclear Regulatory Commission (NRC) and CNP ITS Conversion Website (Attachment 1) suitable for posting on the CNP Unit 1 and Unit 2 docket, Docket Nos. 50-315 and 50-316, respectively. This is necessary because the information provided on the NRC and CNP ITS Conversion Website was used by I&M in the development of Reference 2, and documents the NRC review process for approving the requested amendments to the CNP Unit 1 and Unit 2 Facility Operating Licenses.

As noted in Reference 2, the supplemental changes to the original ITS submittal remain within the scope of the original conversion from CTS to ITS. I&M has evaluated this proposed change, including the supplemental changes described in Reference 2, in accordance with 10 CFR 50.91(a)(1) using the criteria of 10 CFR 50.92(c), and has concluded that the determination of no significant hazards considerations for the original ITS submittal remains valid. In addition, 1&M has determined that the proposed license amendment, including this supplement to the original ITS submittal described in Reference 2, continues to meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(b), and no environmental impact statement or environmental assessment need be prepared in connection with the proposed license amendment. The determination of no significant hazards consideration and environmental assessment, including revisions where applicable, are also included in Reference 2.

As part of the NRC review of Reference 1, NRC questions were provided using the NRC and CNP ITS Conversion Website. The NRC and CNP ITS Conversion Website was developed specifically to expedite NRC review and minimize the time delay between NRC review and posting of NRC questions, development and posting of I&M responses, and acceptance and closure of each identified NRC question by the responsible NRC reviewer. As agreed to between the NRC and I&M, entry of NRC questions and I&M responses to the NRC and CNP ITS Conversion Website is protected so that only the NRC reviewers and I&M staff can enter infornation into the associated database fields for each item. In addition, only the NRC reviewers and I&M staff can attach additional electronic documentation associated with an NRC question or I&M response. However, the public can fully access all infonmation on the NRC and CNP ITS Conversion WVebsite at any time, including NRC questions, l&M responses, and any attached electronic documentation.

Attachment I includes all NRC questions that have been closed by the NRC reviewers as of February 16,2005, along with l&M responses in the NRC and CNP ITS Conversion Website database and all associated attachments, and is arranged chronologically by the dates of the original NRC questions. As of the date of this letter, no outstanding open items are anticipated to require any change to the document provided as Attachment 1. , "Affinmation," provides an oath and affirmation affidavit regarding the statements made and matters set forth in this submittal.

U. S. Nuclear Regulatory Commission AEP:NRC:5901-02 Page 3 This letter contains no commitments. If you have any questions or require additional information, please contact Mr. Richard J. Grumbir, Project Manager, ITS, at (269) 697-5141.

Sincerely, M. K. Nazar Senior Vice President d Chief Nuclear Officer GW/rdw

Enclosure:

1. Affirmation

Attachment:

1. U. S. Nuclear Regulatory Commission (NRC) and Donald C. Cook Nuclear Plant (CNP)

Improved Technical Specification (ITS) Conversion Website (As of February 16, 2005)

NOTE A single copy of this cover letter, enclosure, and attachment is being submitted to the NRC Document Control Desk. In addition, a single CD-ROM suitable for use for entry of this complete submittal into the NRC Agencywide Documents Access and Management System (ADAMS) is being provided. The single copy of the submittal and CD-ROM provided meet the applicable requirements of Regulatory Issue Summary (RIS) 2001-05, "Guidance on Submitting Documents to the NRC by Electronic Information Exchange or on CD-ROM." Additional CD-ROMs are provided for the persons designated below.

c: T. H. Boyce, NRC Washington, DC, w/o attachment, with CD-ROM J. L. Caldwell, NRC Region III, w/o attachment, with CD-ROM K. D. Curry, Ft. Wayne AEP, w/o enclosure/attachment J. N. Donohew, NRC Washington, DC, w/o attachment, with CD-ROM P. C. Hearn, NRC Washington, DC, w/o attachment, with CD-ROM J. T. King, MPSC, w/o enclosure/attachment C. F. Lyon - NRC Washington DC, w/o attachment, with CD-ROM MDEQ - WHMD/HWRPS, w/o enclosure/attachment NRC Resident Inspector, w/o attachment, with CD-ROM

Enclosure 1 to AEP:NRC:5901-02 AFFIRMATION 1, Mano K. Nazar, being duly sworn, state that I am Senior Vice President and Chief Nuclear Officer of American Electric Power Service Corporation and Vice President of Indiana Michigan Power Company (I&M), that I am authorized to sign and file this request with the Nuclear Regulatory Commission on behalf of I&M, and that the statements made and the matters set forth herein pertaining to I&M are true and correct to the best of my knowledge, information, and belief.

American Electric Power Service Corporation ry I.W a M. K. Nazar Senior Vice President 1/ Chief Nuclear Officer SWORN TO AND SUBSCRIBED BEFORE ME THIS 1!112 DAY OFp A \i , 2005 "A.16AA