TAC:MC2629, Increase Flexibility in Mode Restraints, Surveillance Test Interval Extensions for Components of the Reactor Protection System - WCAP-15376-P, Revise LCO 3.5.5 for RCP Seal Injection Flow Resistance (Approved, Closed) TAC:MC2630, Increase Flexibility in Mode Restraints, Surveillance Test Interval Extensions for Components of the Reactor Protection System - WCAP-15376-P, Revise LCO 3.5.5 for RCP Seal Injection Flow Resistance (Approved, Closed) |
|
MONTHYEARML0413103752004-05-18018 May 2004 Ltr, License Amendment Request for the Conversion of Current Technical Specifications to Improved Technical Specifications Project stage: Other ML0429308112004-12-14014 December 2004 Environmental Assessment Finding of No Significant Impact for the Proposed Conversion to the Improved Technical Specifications Project stage: Other ML0514405062005-04-15015 April 2005 Supplement to License Amendment Request - Conversion of Current Technical Specifications to Improved Technical Specifications Project stage: Supplement ML0511503492005-04-15015 April 2005 Transmittal of Donald C. Cook, Units 1 and 2 - Copy of NRC and Plant Improved Technical Specifications Conversion Website Project stage: Request ML0513202432005-04-15015 April 2005 Supplement to License Amendment Request - Conversion of Current Technical Specifications to Improved Technical Specifications Project stage: Supplement ML0511503802005-04-15015 April 2005 Units I and 2, Copy of Proposed Facility Operating Licenses, Improved Technical Specifications, and Improved Technical Specifications Bases Pages Project stage: Other ML0511105402005-04-15015 April 2005 Comments on Plant Draft Safety Evaluation for the Conversion to Improved Technical Specifications Project stage: Draft Other ML0511105322005-04-15015 April 2005 Comments on Plant Draft Safety Evaluation for the Conversion to Improved Technical Specifications Project stage: Draft Other ML0513200192005-05-17017 May 2005 Information Provided in E-Mail Dated April 20, 2005, for Donald C. Cook Nuclear Plant for the ITS Conversion Amendments Project stage: Other ML0506200342005-06-0101 June 2005 License Amendments, Issuance of Amendments for the Conversion to the Improved Technical Specifications with Beyond Scope Issues (TAC Nos. MC2629, MC2630, Etc.) Project stage: Approval ML0515304402005-06-0101 June 2005 Technical Specifications, Issuance of Amendments for the Conversion to the Improved Technical Specifications with Beyond Scope Issues (TAC Nos. MC2629, MC2630, Etc.) Project stage: Approval ML0519903592005-07-0505 July 2005 Correction of Administrative Error for Improved Technical Specifications Project stage: Other ML0522202662005-07-29029 July 2005 Application for Technical Specification Improvement to Eliminate Requirements to Provide Monthly Operating Reports and Occupational Radiation Exposure Reports Project stage: Request ML0522803072005-08-0505 August 2005 Correction of Administrative Error for Improved Technical Specifications Project stage: Other ML0610805842006-04-21021 April 2006 Correction of Amendments Technical Specifications, Conversion to Improved Format Project stage: Acceptance Review 2005-06-01
[Table View] |
Similar Documents at Cook |
---|
Category:Letter
MONTHYEARIR 05000315/20230042024-01-31031 January 2024 Integrated Inspection Report 05000315/2023004 and 05000316/2023004 ML24004A1582024-01-19019 January 2024 Exemption from Select Requirements of 10 CFR Part 73 (EPID L-2023-LLE-0039 (Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting)) AEP-NRC-2024-01, Emergency Plan Revision 482024-01-0808 January 2024 Emergency Plan Revision 48 AEP-NRC-2023-56, Report Per Technical Specification 5.6.6 for Inoperability of Unit 1 Post Accident Monitoring Reactor Coolant (Loop 3 Cold Leg) Wide Range Temperature Recorder Thermal Sensor2023-12-20020 December 2023 Report Per Technical Specification 5.6.6 for Inoperability of Unit 1 Post Accident Monitoring Reactor Coolant (Loop 3 Cold Leg) Wide Range Temperature Recorder Thermal Sensor ML23352A3502023-12-19019 December 2023 Dc. Cook Nuclear Power Plant, Units 1 Biennial Licensed Operator Requalification Program Inspection and Request for Information ML23338A2642023-12-0505 December 2023 Confirmation of Initial License Examination AEP-NRC-2023-45, Unit 2 - Schedular Exemption for Enhanced Weapons, Firearms, Background Checks, and Security Event Notifications Implementation2023-11-16016 November 2023 Unit 2 - Schedular Exemption for Enhanced Weapons, Firearms, Background Checks, and Security Event Notifications Implementation IR 05000315/20234042023-11-0606 November 2023 Cyber Security Inspection Report 05000315/2023404 and 05000316/2023404 ML23310A1152023-11-0606 November 2023 Notification of the NRC Baseline Inspection and Request for Information, Inspection Report 05000316/2024002 IR 05000315/20234032023-09-19019 September 2023 Security Baseline Inspection Report 05000315/2023403 and 05000316/2023403 IR 05000315/20230112023-08-31031 August 2023 Functional Engineering Inspection - Commercial Grade Dedication Report 05000315/2023011 and 05000316/2023011 ML23242A1832023-08-30030 August 2023 Notification of NRC Baseline Inspection and Request for Information; Inspection Report05000315/2023004 AEP-NRC-2023-40, Annual Report of Loss-of-Coolant Accident Evaluation Model Changes2023-08-29029 August 2023 Annual Report of Loss-of-Coolant Accident Evaluation Model Changes IR 05000315/20234022023-08-11011 August 2023 Security Baseline Inspection Report 05000315/2023402 and 05000316/2023402 AEP-NRC-2023-34, Supplement to Request for Approval of Change Regarding Neutron Flux Instrumentation2023-08-0202 August 2023 Supplement to Request for Approval of Change Regarding Neutron Flux Instrumentation IR 05000315/20230022023-07-24024 July 2023 Integrated Inspection Report 05000315/2023002 and 05000316/2023002 ML23178A2422023-06-28028 June 2023 Reassignment of the U.S. Nuclear Regulatory Commission Branch Chief in the Division of Operating Reactor Licensing for Plant Licensing Branch III IR 05000315/20230122023-06-22022 June 2023 Biennial Problem Identification and Resolution Inspection Report 05000315/2023012 and 05000316/2023012 IR 05000315/20235012023-06-21021 June 2023 Emergency Preparedness Biennial Exercise Inspection Report 05000315/2023501 and 05000316/2023501 AEP-NRC-2023-29, Core Operating Limits Report2023-06-19019 June 2023 Core Operating Limits Report ML23159A0192023-06-13013 June 2023 Information Meeting with a Question and Answer Session to Discuss NRC 2022 End-Of-Cycle Plant Performance Assessment of Donald C. Cook Nuclear Plant, Units 1 and 2 AEP-NRC-2023-32, Response to NRC Regulatory Issue Summary 2023-1 Preparation and Scheduling of Operator Licensing Examinations2023-06-0606 June 2023 Response to NRC Regulatory Issue Summary 2023-1 Preparation and Scheduling of Operator Licensing Examinations AEP-NRC-2023-33, Renewable Operating Permit2023-06-0505 June 2023 Renewable Operating Permit AEP-NRC-2023-30, Follow-Up Notification of Ph Non-Compliance for Turbine Room Sump2023-06-0101 June 2023 Follow-Up Notification of Ph Non-Compliance for Turbine Room Sump AEP-NRC-2023-27, Annual Radiological Environmental Operating Report2023-05-15015 May 2023 Annual Radiological Environmental Operating Report ML23131A3282023-05-11011 May 2023 D.C. Cook Information Request for the Cyber-Security Baseline Inspection, Notification to Perform Inspection 05000315/2023404 and 05000316/2023404 IR 05000315/20230012023-05-0303 May 2023 Integrated Inspection Report 05000315/2023001 and 05000316/2023001 AEP-NRC-2023-19, Annual Radioactive Effluent Release Report2023-04-30030 April 2023 Annual Radioactive Effluent Release Report ML23117A0062023-04-27027 April 2023 Review of the Spring 2022 Steam Generator Tube Inspections Report ML23114A1142023-04-25025 April 2023 Information Request to Support the NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection AEP-NRC-2023-23, Annual Report of Individual Monitoring for 20222023-04-24024 April 2023 Annual Report of Individual Monitoring for 2022 AEP-NRC-2023-24, Notification of Ph Non-Compliance for Turbine Room Sump2023-04-12012 April 2023 Notification of Ph Non-Compliance for Turbine Room Sump AEP-NRC-2023-20, Annual Report of Property Insurance2023-04-0303 April 2023 Annual Report of Property Insurance AEP-NRC-2023-15, Decommissioning Funding Status Report2023-03-28028 March 2023 Decommissioning Funding Status Report ML23076A0212023-03-20020 March 2023 Request for Information for NRC Commercial Grade Dedication Inspection; Inspection Report 05000315/2023011; 05000316/2023011 IR 05000315/20234012023-03-16016 March 2023 Security Baseline Inspection Report 05000315/2023401 and 05000316/2023401 ML23066A1882023-03-0707 March 2023 Information Request to Support Upcoming Problem Identification and Resolution (Pi&R) Inspection at Donald C. Cook Nuclear Plant IR 05000315/20220062023-03-0101 March 2023 Annual Assessment Letter for Donald C. Cook Nuclear Plant, Units 1 and 2 (Report 05000315/2022006 and 05000316/2022006) IR 05000315/20220042023-02-0101 February 2023 Integrated Inspection Report 05000315/2022004 and 05000316/2022004 and Exercise of Enforcement Discretion AEP-NRC-2023-11, Form OAR-1, Owner'S Activity Report2023-01-31031 January 2023 Form OAR-1, Owner'S Activity Report IR 05000315/20230102023-01-31031 January 2023 Phase 4 Post-Approval License Renewal Inspection Report 05000315/2023010 and 05000316/2023010 AEP-NRC-2023-02, Request for Approval of Change Regarding Neutron Flux Instrumentation2023-01-26026 January 2023 Request for Approval of Change Regarding Neutron Flux Instrumentation ML22363A5622023-01-0404 January 2023 Relief Request ISIR-5-06 Related to ASME Code Case N-729-6 Supplemental Examination Requirements of Reactor Vessel Closure Head Penetration Nozzles AEP-NRC-2022-66, Report Per Technical Specification 5.6.6 for Inoperability of Unit 2 Post Accident Monitoring Neutron Flux Monitoring2022-12-15015 December 2022 Report Per Technical Specification 5.6.6 for Inoperability of Unit 2 Post Accident Monitoring Neutron Flux Monitoring AEP-NRC-2022-46, Notification of Deviation from Electric Power Research Institute (EPRI) Materials Reliability Program 2019-008, Interim Guidance for NEI 03-08 Needed Requirements for Us PWR Plants for Management of Thermal Fatigue in2022-12-12012 December 2022 Notification of Deviation from Electric Power Research Institute (EPRI) Materials Reliability Program 2019-008, Interim Guidance for NEI 03-08 Needed Requirements for Us PWR Plants for Management of Thermal Fatigue in ML22340A1392022-11-30030 November 2022 Submittal of Revision 31 to Updated Final Safety Analysis Report and 10CFR50.71(e) Updated and Related Site Change Reports IR 05000315/20220112022-11-0404 November 2022 Design Basis Assurance Inspection (Teams) Inspection Report 05000315/2022011 and 05000316/2022011 IR 05000315/20220032022-10-28028 October 2022 Integrated Inspection Report 05000315/2022003 and 05000316/2022003 AEP-NRC-2022-58, U1C31 Steam Generator Tube Inspection Report2022-10-24024 October 2022 U1C31 Steam Generator Tube Inspection Report AEP-NRC-2022-61, Request for Relief Related to American Society of Mechanical Engineers (ASME) Code Case N-729-6 Supplemental Examination Requirements, ISIR-5-062022-10-24024 October 2022 Request for Relief Related to American Society of Mechanical Engineers (ASME) Code Case N-729-6 Supplemental Examination Requirements, ISIR-5-06 2024-01-08
[Table view] |
Text
Indiana Michigan Power INDIANA Cook Nuclear Plant MICHIGAN One Cook Place Bridgman, MI 49106 POWER' AEP.com Aunit ofAmerican Electric Powver April 15, 2005 AEP:NRC:5901-02 10 CFR 50.90 Docket Nos. 50-315 50-316 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001 Donald C. Cook Nuclear Plant, Units 1 and 2 COPY OF U. S. NUCLEAR REGULATORY COMMISSION AND DONALD C. COOK NUCLEAR PLANT IMPROVED TECHNICAL SPECIFICATIONS CONVERSION WEBSITE (TAC NOS. MC2629 AND MC2630)
References:
- 1. Letter from M. K. Nazar, Indiana Michigan Power Company, to Nuclear Regulatory Commission Document Control Desk, 'Donald C. Cook Nuclear Plant Unit 1 and Unit 2, License Amendment Request - Conversion of Current Technical Specifications (CTS) to Improved Technical Specifications (ITS)," AEP:NRC:4901, dated April 6, 2004.
- 2. Letter from J. N. Jensen, Indiana Michigan Power Company, to Nuclear Regulatory Commission Document Control Desk, "Donald C. Cook Nuclear Plant Units 1 and 2, Supplement to License Amendment Request - Conversion of Current Technical Specifications (CTS) to Improved Technical Specifications (ITS),
(TAC Nos. MC2629 and MC2630)," AEP:NRC:5901, dated April 15, 2005.
Dear Sir or Madam:
By References 1 and 2, Indiana Michigan Power Company (I&M) submitted an original and supplemental application to amend Appendix A, Technical Specifications, of Donald C. Cook Nuclear Plant (CNP) Unit 1 and Unit 2 Facility Operating Licenses DPR-58 and DPR-74, respectively, revising the current Technical Specifications (CTS) to the Improved Technical Specifications (ITS) consistent with Improved Standard Technical Specifications as described in NUREG-1431, "Standard Technical Specifications - Westinghouse Plants," Revision 2, and certain generic changes to the NUREG.
Azon
U. S. Nuclear Regulatory Commission AEP:NRC:5901-02 Page 2 The purpose of this letter is to provide a complete copy of the joint U. S. Nuclear Regulatory Commission (NRC) and CNP ITS Conversion Website (Attachment 1) suitable for posting on the CNP Unit 1 and Unit 2 docket, Docket Nos. 50-315 and 50-316, respectively. This is necessary because the information provided on the NRC and CNP ITS Conversion Website was used by I&M in the development of Reference 2, and documents the NRC review process for approving the requested amendments to the CNP Unit 1 and Unit 2 Facility Operating Licenses.
As noted in Reference 2, the supplemental changes to the original ITS submittal remain within the scope of the original conversion from CTS to ITS. I&M has evaluated this proposed change, including the supplemental changes described in Reference 2, in accordance with 10 CFR 50.91(a)(1) using the criteria of 10 CFR 50.92(c), and has concluded that the determination of no significant hazards considerations for the original ITS submittal remains valid. In addition, 1&M has determined that the proposed license amendment, including this supplement to the original ITS submittal described in Reference 2, continues to meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(b), and no environmental impact statement or environmental assessment need be prepared in connection with the proposed license amendment. The determination of no significant hazards consideration and environmental assessment, including revisions where applicable, are also included in Reference 2.
As part of the NRC review of Reference 1, NRC questions were provided using the NRC and CNP ITS Conversion Website. The NRC and CNP ITS Conversion Website was developed specifically to expedite NRC review and minimize the time delay between NRC review and posting of NRC questions, development and posting of I&M responses, and acceptance and closure of each identified NRC question by the responsible NRC reviewer. As agreed to between the NRC and I&M, entry of NRC questions and I&M responses to the NRC and CNP ITS Conversion Website is protected so that only the NRC reviewers and I&M staff can enter infornation into the associated database fields for each item. In addition, only the NRC reviewers and I&M staff can attach additional electronic documentation associated with an NRC question or I&M response. However, the public can fully access all infonmation on the NRC and CNP ITS Conversion WVebsite at any time, including NRC questions, l&M responses, and any attached electronic documentation.
Attachment I includes all NRC questions that have been closed by the NRC reviewers as of February 16,2005, along with l&M responses in the NRC and CNP ITS Conversion Website database and all associated attachments, and is arranged chronologically by the dates of the original NRC questions. As of the date of this letter, no outstanding open items are anticipated to require any change to the document provided as Attachment 1. , "Affinmation," provides an oath and affirmation affidavit regarding the statements made and matters set forth in this submittal.
U. S. Nuclear Regulatory Commission AEP:NRC:5901-02 Page 3 This letter contains no commitments. If you have any questions or require additional information, please contact Mr. Richard J. Grumbir, Project Manager, ITS, at (269) 697-5141.
Sincerely, M. K. Nazar Senior Vice President d Chief Nuclear Officer GW/rdw
Enclosure:
- 1. Affirmation
Attachment:
- 1. U. S. Nuclear Regulatory Commission (NRC) and Donald C. Cook Nuclear Plant (CNP)
Improved Technical Specification (ITS) Conversion Website (As of February 16, 2005)
NOTE A single copy of this cover letter, enclosure, and attachment is being submitted to the NRC Document Control Desk. In addition, a single CD-ROM suitable for use for entry of this complete submittal into the NRC Agencywide Documents Access and Management System (ADAMS) is being provided. The single copy of the submittal and CD-ROM provided meet the applicable requirements of Regulatory Issue Summary (RIS) 2001-05, "Guidance on Submitting Documents to the NRC by Electronic Information Exchange or on CD-ROM." Additional CD-ROMs are provided for the persons designated below.
c: T. H. Boyce, NRC Washington, DC, w/o attachment, with CD-ROM J. L. Caldwell, NRC Region III, w/o attachment, with CD-ROM K. D. Curry, Ft. Wayne AEP, w/o enclosure/attachment J. N. Donohew, NRC Washington, DC, w/o attachment, with CD-ROM P. C. Hearn, NRC Washington, DC, w/o attachment, with CD-ROM J. T. King, MPSC, w/o enclosure/attachment C. F. Lyon - NRC Washington DC, w/o attachment, with CD-ROM MDEQ - WHMD/HWRPS, w/o enclosure/attachment NRC Resident Inspector, w/o attachment, with CD-ROM
Enclosure 1 to AEP:NRC:5901-02 AFFIRMATION 1, Mano K. Nazar, being duly sworn, state that I am Senior Vice President and Chief Nuclear Officer of American Electric Power Service Corporation and Vice President of Indiana Michigan Power Company (I&M), that I am authorized to sign and file this request with the Nuclear Regulatory Commission on behalf of I&M, and that the statements made and the matters set forth herein pertaining to I&M are true and correct to the best of my knowledge, information, and belief.
American Electric Power Service Corporation ry I.W a M. K. Nazar Senior Vice President 1/ Chief Nuclear Officer SWORN TO AND SUBSCRIBED BEFORE ME THIS 1!112 DAY OFp A \i , 2005 "A.16AA
&ItayPublic My Commission Expires Le~"e,I I
.. ..