UNITED STATES

NUCLEAR REGULATORY COMMISSION

OFFICE OF NUCLEAR REACTOR REGULATION

OFFICE OF NUCLEAR MATERIAL SAFETY AND SAFEGUARDS

WASHINGTON, DC 20555 May 17, 2005 NRC INFORMATION NOTICE 2005-12:

EXCESSIVELY LARGE CRITICALITY SAFETY

LIMITS FAIL TO PROVIDE DOUBLE

CONTINGENCY AT FUEL CYCLE FACILITY

ADDRESSEES

All licensees authorized to possess a critical mass of special nuclear material.

PURPOSE

The U.S. Nuclear Regulatory Commission (NRC) is issuing this information notice (IN) to inform

addressees of a concern related to criticality safety at fuel fabrication and other facilities

processing, storing, or handling critical masses of fissile material. It is expected that licensees

will review this information and consider actions, as appropriate, to avoid similar problems.

However, suggestions contained in this IN are not new NRC requirements; therefore, no specific

action nor written response is required.

DESCRIPTION OF CIRCUMSTANCES

During a recent plant-wide review of criticality safety analysis at a fuel cycle licensee, a licensee

criticality safety engineer questioned the utility of a control scheme that relied on mass and

moderator controls for double contingency in a large uranium dioxide powder hopper.

Experience and process knowledge caused the engineer to believe that the controls were too

high and that exceeding one limit could lead to a critical configuration under credible

circumstances, without requiring the other limit to be exceeded.

Licensee investigation revealed that the system had previously relied on a level limit and that

during a revision of the safety basis, the controls had been changed to support new mass and

moderator limits. The licensee determined that the new mass and moderator limits had been

derived from the previous level limit (i.e., by determining how much mass was present at the

maximum allowed level and then determining how much moderator was required to make the

system critical in that configuration). There was no accompanying analysis to demonstrate that

the new values were actually limiting. The licensee demonstrated that, in fact, increasing the

amount of mass could make the system critical without exceeding the moderation limit.

DISCUSSION

Under 10 CFR Parts 70 and 76, certain licensees processing, storing, or handling critical

masses of fissile material are required to analyze accident scenarios leading to criticality, establish subcritical limits, and provide reliable controls to provide an acceptable level of

assurance that the subcritical limits are not exceeded. Dual, independent controls provide the

basis for double contingency protection against inadvertent criticality. Fuel cycle licensees

generally implement criticality safety controls on important process parameters that, when

upset, may create a critical system.

NRC has several concerns about this issue. The first is that the practice of deconstructing an

existing criticality safety limit was apparently the licensees common practice, which many

licensee criticality safety engineers used for years, resulting in a number of questionable control

arrangements in the technical safety basis. This practice is associated with an expansion of an

established limit. The second concern is the failure to perform needed analysis to assure that

newly developed criticality safety limits would not lead to a critical system by their individual

failure and would ensure double contingency. No explicit modeling was performed for this

analysis, and such modeling is not normally performed for limits not based on computer analysis

due to conservatism normally employed. The final concern is the failure of licensee technical

reviewers and management to detect the excessively high limits during routine review and

approval. Review of these new limits did not include thorough examination and questioning of

existing technical analysis and assumptions.

Failure to establish and maintain fully independent nuclear criticality safety controls exposes

fuel cycle licensees to the possibility of failure of double contingency. Licensees should

consider actions, as appropriate, to identify and mitigate this vulnerability. Appropriate actions

may include: (1) identification of double contingency arrangements based on tabulated values, hand calculations, or other related approximations, such as one-dimensional computer analysis, that may result in the questionable limits being identified, (2) analysis to establish the adequacy

of the controls intended to support the limits identified in item (1), and (3) incorporation of

appropriate requirements into routine review and approval protocol to assure implementation of

suitably robust double contingency arrangements when new criticality safety limits are derived

from previous limits.

CONTACT

This IN requires no specific action nor written response. Questions about this matter may be

referred to the technical contact listed below.

/RA/

/RA/

Patrick L. Hiland, Chief

Robert C. Pierson, Director

Reactor Operations Branch

Division of Fuel Cycle Safety

Division of Inspection Program Management

and Safeguards

Office of Nuclear Reactor Regulation

Office of Nuclear Material Safety

and Safeguards

Technical Contact:

Dennis Morey, NMSS

301-415-6107 e-mail: dcm@nrc.gov

Attachment: List of Recently Issued NMSS Generic Communications

Note: NRC generic communications may be found on the NRC public Web site, http://www.nrc.gov, under Electronic Reading Room/Document Collections.

CONTACT

This IN requires no specific action nor written response. Questions about this matter may be

referred to the technical contact listed below.

/RA/

/RA/

Patrick L. Hiland, Chief

Robert C. Pierson, Director

Reactor Operations Branch

Division of Fuel Cycle Safety

Division of Inspection Program Management

and Safeguards

Office of Nuclear Reactor Regulation

Office of Nuclear Material Safety

and Safeguards

Technical Contact:

Dennis Morey, NMSS

301-415-6107 e-mail: dcm@nrc.gov

Attachment: List of Recently Issued NMSS Generic Communications

Note: NRC generic communications may be found on the NRC public Web site, http://www.nrc.gov, under Electronic Reading Room/Document Collections.

ADAMS ACCESSION #: ML051080466 OFC

FCSS/TSG

Tech Editor

FCSS/TSC

FCSS/TSG

NRR

NAME

DMorey:dw*

EKraus*

RCesaro*

MGalloway*

JWermiel

DATE

04/ /05

04/29/05

05/03/05

05/03/05

05/10/05 OFC

NRR

NRR

FCSS

NAME

CRoque-Cruz

PHiland

RPierson

DATE

05/13/05

05/13/05

05/ 17 /05

OFFICIAL RECORD COPY

Attachment 1

IN 2005 -12 Recently Issued NMSS Generic Communications

Date

GC No.

Subject

Addressees

04/18/05 RIS-05-06

Reporting Requirements for

Gauges Damaged at

Temporary Job Sites

All material licensees possessing

portable gauges, regulated under

10 CFR Part 30.

04/14/05 RIS-05-04

Guidance on the Protection

of Unattended Openings

that Intersect a Security

Boundary or Area

All holders of operating licenses

or construction permits for nuclear

power reactors, research and test

reactors, decommissioning

reactors with fuel on site, Category 1 fuel cycle facilities, critical mass facilities, uranium

conversion facility, independent

spent fuel storage installations, gaseous diffusion plants, and

certain other material licensees.

02/28/05 RIS-05-003

10 CFR Part 40

Exemptions for Uranium

Contained in Aircraft

Counterweights - Storage

and Repair

All persons possessing aircraft

counterweights containing

uranium under the exemption in

10 CFR 40.13(c)(5).

05/17/05 IN-05-013 Potential Non-conservative

Error in Modeling

Geometric Regions in the

Keno-v.a Criticality Code

All licensees using the Keno-V.a

criticality code module in

Standardized Computer Analyses

for Licensing Evaluation (SCALE)

software developed by Oak Ridge

National Laboratory (ORNL)

05/17/05 IN-05-012

Excessively Large Criticality

Safety Limits Fail to Provide

Double Contingency at Fuel

Cycle Facility

All licensees authorized to

possess a critical mass of special

nuclear material.

04/07/05 IN-05-010

Changes to 10 CFR Part 71

Packages

All 10 CFR Part 71 licensees and

certificate holders.

04/01/05 IN-05-007

Results of HEMYC

Electrical Raceway Fire

Barrier System Full Scale

Fire Testing

All holders of operating licenses

for nuclear power reactors, except

those who have permanently

ceased operations and have

certified that fuel has been

permanently removed from the

reactor vessel, and fuel facilities

licensees.

03/10/05 IN-05-005

Improving Material Control

and Accountability Interface

with Criticality Safety

Activities at Fuel Cycle

Facilities

All licensees authorized to

possess a critical mass of special

nuclear material.

Note: NRC generic communications may be found on the NRC public website, http://www.nrc.gov, under Electronic Reading Room/Document Collections.