Text
AmerGen Energy Company, LLC www.exeloncorp.com AmerGen An Exelon Company SM Oyster Creek US Route 9 South, P.O. Box 388 Forked River, NJ o8731-0388 ASME Code, Section Xi 10CFR50.55a February 16, 2005 2130-05-20037 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Oyster Creek Generating Station Facility License No. DPR-16 Docket No. 50-219
Subject:
Oyster Creek Generating Station Refueling Outage 20 (1R20) Inservice Inspection (ISI) Summary Report
Reference:
United States Nuclear Regulatory Commission (USNRC) letter dated November 12, 2004, "Oyster Creek Nuclear Generating Station -
Altemative Repair of Control Rod Drive Housing Interface With Reactor Vessel (TAC NO. MC1099)"
Submittal of the Owner's Data Reports for Inservice Inspections is required by the American Society of Mechanical Engineers (ASME) Code, Section Xl. Attachment 1, "NIS-1 Owner's Data Report for Inservice Inspections," covers the Oyster Creek Generating Station Refueling Outage 20 (1R20) examinations conducted between October 28, 2002 and November 22, 2004. The report includes the first period, of the Fourth Inservice Inspection (ISI) interval examinations performed in accordance with the ASME Code, Section Xl, 1995 Edition with 1996 Addenda.
Attachment'2, "Form NIS-1 for Containment ISI Program - IWE," includes the NIS-1 Form covering OCGS Data Report for Containment Inservice Inspections where documentation was completed between October 28, 2002 and November 22, 2004. The report includes the second period of the First Inservice Inspection (ISI) interval examinations performed in accordance with the ASME Code, Section Xl, 1992 Edition with 1992 Addenda. , 'Form NIS-2 Owners Report for Repairs or Replacements," includes the NIS-2 Forms covering repairs or replacements where documentation was completed between October 28, 2002 and November 22, 2004.
In the Referenced letter, the U. S. Nuclear Regulatory Commission (NRC) provided approval of a proposed alternative to 10 CFR 50.55a(g) concerning the roll repair of control rod drive penetrations at Oyster Creek Generating Station. In the Safety Evaluation Report, the NRC requested that we provide the results of the VT-2 inspections Au7
2130-05-20037 of all CRD penetrations, including the rolled penetrations, and the inspection results of the housing inside diameter of drive 46-39, performed this past outage.
The VT-2 inspection of all the drives was performed during shutdown and startup did not identify any leakage. Additionally, the UT inspection of the inside diameter of control rod drive housing 46-39 did not identify any indications.
If you should have any questions, please contact the Oyster Creek ISI Coordinator, Mr.
Greg Harttraft at 609-971-2287.
C. N. Swenson Vice President. Ov ter Creek Generating Station CNS/DIF
Enclosure:
OCGS ISI Post 1R20 Outage Summary Report cc: S. J. Collins, USNRC, Regional Administrator, Region I P. S. Tam, USNRC, Senior Project Manager, OCGS R. J. Summers, USNRC, Senior NRC Resident Inspector, TMI Scott Laley, Hartford Steam Boiler I&l Co. of CT File No. 05014
Attachment I Oyster Creek Generating Station ISI Post 1R20 Outage Summary Report
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1. Owner AmerGen Energy Co. L.L.C., 200 Exelon Way. Kennett Square. PA 19348 (Name and Address of Owner)
- 2. Plant Oyster Creek Generating Station, Route 9 South, Forked River, NJ 08731 (Name and Address of Plant)
- 3. Unit Unit 1 4. Owner Certificate of Authorization (if required) N/A
- 5. Commercial Service Date 12/23/69 6. National Board Number for Unit Reactor Vessel 14895
- 7. Components Inspected ISI Program (See attached Table 1)
Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No. Providence No. Board No.
Reactor Vessel Combustion Engineering 14895 Class 1 & 2 Piping and Supports I I 4 4 4 4 4 4 + 4 4 4 4. 4 4 4 + 4 4 4 4. I Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (I) size is 8 1/2 in. x II in., (2) information in items I through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets recorded at the top of this form.
FORM NIS-1 (back)
- 8. Examination Dates 10/28/02 to 11/22/04
- 9. Inspection Period Identification: First Period
- 10. Inspection Interval Identification: Fourth Inspection Interval
- 11. Applicable Editions for Section XI 1995 Addenda 1996
- 12. Date / Revision of Inspection Plan: 9/30/04 Rev. I
- 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See attached
- 14. Abstract of Results of Examinations and Tests. See attached
- 15. Abstract of Corrective Measures. See attached We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.
Certificate of Authorization No. (if applicable) None Expiration Date N/A Date 0Signed AmerGen Energy Co.. L.L.C. BY y I 1 i t°(- X/6.
CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of New Jersey and employed by H-SB of CT have inspected the components described in this Owners' Data Report during the period/ to/ and state that to the best of my knowledge and belief, the Owner has performed examinati and ta e corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Date Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of a darising from or connected with this inspection.
Commissions NB 9364 (1) (N NJ766 Inspector's ature National Board, State, Province and No.
Date 2 //O /2005 t I
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS Form NIS-1 for ISI Program
- 13. Abstract of Examinations and Tests This submittal is for the ISI examinations performed during the Oyster Creek Generating Station 1R20 refuel outage. This is Oyster Creek's first submittal for the fourth inspection interval. The exams were completed in accordance with the 1995 Edition of the ASME Code with 1996 Addenda.
One hundred sixty three (163) exams were completed on Class 1 and 2 systems for ASME Section Xl requirements, ten (10) exams were completed for augmented requirements, and seventeen (17) exams were completed for Generic Letter 88-01 requirements. In addition, visual and UT examinations were completed on the drywell and torus in accordance with ASME Section IWE (Containment Program). In summary, all examinations were completed successfully.
Refueling Outage Inspection Results for the CRD Housing Inspections During the 1R20 outage, AmerGen performed inspections of the CRD housings to identify any leakage from the RPV bottom head penetrations. No leakage was observed during the drywell 1000 lb. VT-2 inspection performed during the initial shutdown. During the outage, undervessel inspections were performed on all CRD housings during set-up activities for CRD exchange (RPV vented) and no stub tube leakage was identified from the RPV bottom head.
Based on a target of opportunity for access to one of the roll repaired CRD housings, the CRD housing bore at core location 46-39 was UT inspected. Both the roll repair area and the J weld area above it were UT inspected with no indications. Undervessel VT-2 inspections were also performed during the RPV pressure test at approximately 1000 Ibs and no stub tube leakage was found (WO R2032133). A final undervessel inspection was performed during the plant startup drywell 10001b. Inspection and no stub tube leakage was found.
- 14. Abstract of Results of Examinations and Tests Welds categorized as B-J, C-F-1 and C-F-2 were examined to the requirements of PDI, in compliance with the amended requirements of 10CFR50.55a for implementation of appendix VIII of the ASME Section Xl, 1995 Edition with 1996 Addenda.
The reactor pressure test of the reactor coolant pressure boundary was completed at the end of the outage. Leakage at bolted flange connections was observed on some control rod drives (CRDs) and this was evaluated in accordance with Code Case N-566-1. The alternative pressure test requirements of Code Case N-416-1 were utilized for welded repairs or installation of replacement items by welding.
There were challenges identified during this inspection on the Core Spray system piping supports and the NU-2-2 weld on the shutdown cooling system. In the area of supports, scope expansion (11 extra support exams) was required due to unacceptable as-found conditions on rod hangers.
The NU-2-2 dissimilar metal weld in the drywell was initially identified by manual UT with a flaw.
However, upon re-examination of this weld with improved and automated UT techniques (SMART UT) the flaw was no longer identified and a weld overlay repair was not required.
- 15. Abstract of Corrective Measures See Table 2 for ISI and in-vessel visual inspection (IWI) corrective measures. For ISI components not associated with IWI no indications were detected by the examinations, and there was no through-wall leakage identified at the pressure boundary. Table 3 provides the statistics for ISI examinations completed during the 1R20 outage. Refer to Table 4 for the ISI examinations that were completed that did not meet ASME code coverage requirements. The limitations were due to nozzle geometry, restricted access, and one sided examinations due to attached nozzle or valve.
A relief request will be submitted by the end of the interval for approval of these limited coverage examinations. See Table 5 for system pressure test results.
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION I.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 4.0WNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, &COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: B-A B13.21 ISI NRO2 2-574 WELD UT 221 CIRC 1 09-Nov-04 CLOSURE HEAD CIRC WELD B1.40 ISI NRO2 1-574 WELD SUR 221 CIRC 1 05-Nov-04 REACTOR HEAD TO FLANGE CATEGORY: B-D B3.100 lSI NRO2 3-565C WELD UT 221 NOZZ 1 07-Nov-04 N1C RECIRC OUTLET NOZZLE C-LOOP B3.100 I5 NRO2 3-565D WELD UT 221 NOZZ I 08-Nov-04 N1D RECIRC OUTLET NOZZLE D-LOOP B3.90 lSI NRO2 3-565C WELD UT 221 NOZZ I 07-Nov-04 NIC RECIRC OUTLET NOZZLE C-LOOP B3.90 ISI NRO2 3-565D WELD UT 221 NOZZ 1 08-Nov-04 NID RECIRC OUTLET NOZZLE D-LOOP CATEGORY: B-F B5.10 ISI NRO2 1-566A WELD SUR 221 CIRC 1 04-Nov-04 N5A ISOLATION COND. NOZZLE SAFE E B5.10 IS1 NRO2 1-566A WELD UT 221 CIRC 1 09-Nov-04 N5A ISOLATION COND. NOZZLE SAFE E B5.10 ISI NRO2 1-566B WELD UT 221 CIRC I 05-Nov-04 N5B ISOLATION COND. NOZZLE SAFE E B5.10 ISI NRO2 1-566B WELD SUR 221 CIRC 1 04-Nov-04 N5B ISOLATION COND. NOZZLE SAFE E B5.10 ISI NRO2 2-576 WELD UT 221 CIRC 1 09-Nov-04 N7A NOZZLE TO FLANGE B5.10 IS1 NRO2 4-565C WELD SUR 221 CIRC 1 08-Jan-04 N1C RECIRC OUTLET NOZZLE SAFE EN Page 1 of))
Wednesday, Wednesday, February 09,2005 February 09,2005 Page I1of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 4.0WNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, 5.COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: B-F B5.10 ISI NRO2 4-565C WELD UT 221 CIRC I 07-Nov-04 NlC RECIRC OUTLET NOZZLE SAFE EN B5.10 lSI NRO2 4-565D WELD SUR 221 CIRC 1 07-Nov-04 NID RECIRC OUTLET NOZZLE SAFE EN B5.10 [SI NRO2 4-576 WELD UT 221 CIRC 1 09-Nov-04 N7B FLANGE TO NOZZLE CATEGORY: B-G-1 B6.10 lS NRO2 573-02 BOLT VT-I 221 1 05-Nov-04 CLOSURE NUT (1-32)
B6.50 ISI NRO2 573-07 BOLT VT-1 221 1 05-Nov-04 CLOSURE WASHER BOTTOM (1-32)
B6.50 ISI NRO2 573-08 BOLT VT-i 221 1 05-Nov-04 CLOSURE WASHER UPPER (1-32)
CATEGORY: B-G-2 B7.50 ISI 216-BG-001 BOLT VT-I 216 1 15-Nov-04 BOLTING ON 6"FLANGE RX SIDE REM B7.50 - SI 216-BG-002 BOLT VT-I 216 1 15-Nov-04 BOLTING ON 2"FLANGE PIPE SIDE RE B7.50 ISI 216-BG-003 BOLT VT-1 216 1 15-Nov-04 BOLTING ON TOP 2" FLANGEAT CAVIT B7.50 Si 216-BG-004 BOLT VT-I 216 1 15-Nov-04 BOLTING ON BOTTOM 2" FLANGE ON C B7.50 [SI 221-BG-001 BOLT VT-I 221 1 15-Nov-04 FLANGE ON RX VESSEL HEAD B7.50 ISI 221-BG-002 BOLT VT-I 221 1 15-Nov-04 FLANGE AT CAVITY FLOOR Wednesday, February09,2005 Page2 of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION L.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, &COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: BJ B9.11 IS NZ-3-0042 WELD UT 212 CIRC 1 11-Nov-04 PIPE TO ELBOW B9.11 is NZ-3-0073 WELD UT 212 CIRC 1 12-Nov-04 PIPE TO ELBOW B9.11 ISI NZ-3-0086 WELD UT 212 CIRC 1 10-Nov-04 ELBOW TO PIPE B9.11 IS NZ-3-0089 WELD UT 212 CIRC 1 10-Nov-04 ELBOW TO PIPE B9.1 i IS1 NZ-3-0095R1 WELD UT 212 CIRC 1 07-Nov-04 PIPE TO REDUCER(WELD REPAIRED B B9.11 5i1 NU-1-0007 WELD UT 214 CIRC 1 12-Nov-04 ELBOW TO PIPE B9.11 ISI NU-2-0002 WELD UT 214 CIRC 1 12-Nov-04 ELBOW TO PIPE (BI-METALIC WELD)
B9.11 ISI NU-2-0022 WELD UT 214 CIRC 1 14-Nov-04 ELBOW TO PIPE B9.11 ISI NU-3-0002 WELD UT 214 CIRC 1 13-Nov-04 ELBOW TO PIPE B9.11 ISI NU-3-0004 WELD UT 214 CIRC 1 13-Nov-04 ELBOW TO PIPE B9.11 5lS NG-C-0001A WELD UT 223 CIRC 1 10-Nov-04 SAFE END TO ELBOW B9.11 ISI NG-C-0002 WELD UT 223 CIRC 1 12-Nov-04 ELBOW TO PIPE B9.11 ISI NG-D-0001A WELD UT 223 CIRC I 10-Nov-04 SAFE END TO ELBOW Page 3 of))
Wednesday, 09, 2005 February09, Ifednesday, February 2005 Page 3 of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION I.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, 5.COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: B-J B9.11 ISI MS-1-0030 WELD UT 411 CIRC 1 17-Nov-04 PIPE TO ELBOW B9.11 ISI -- MS-1-0050 WELD UT 411 CIRC 1 04-Nov-04 SAFE END TO ELBOW B9.11 ISi RF-2-0014 WELD UT 422 CIRC 1 06-Nov-04 ELBOW TO PIPE B9.21 1SI RHC-HS-1 WELD SUR 216 CIRC 1 08-Nov-04 REDUCER TO FLANGE PIPE SIDE B9.21 ISI NG-B-0009 WELD SUR 223 CIRC 1 07-Nov-04 PIPE TO ...FLANGE (DECON CONN.)
~~~~...... . . _... _.
B9.21 Is NC-4-0017 WELD SUR 225 CIRC 1 10-Nov-04 PIPE TO ELBOW B9.31 IS MS-1-0057 WELD SUR 411 BRNCH 1 09-Nov-04 PIPE TO BRANCH B9.31 IS! MS-1-0059 WELD SUR 411 BRNCH 1 09-Nov-04 PIPE TO BRANCH B9.32 ISI NG-D-0017 WELD SUR 223 BRNCH 1 06-Nov-04 PIPE TO BRANCH B9.32 ISI NG-E-0009 WELD SUR 223 BRNCH 1 09-Nov-04 ELBOW TO BRANCH B9.40 ISI NP-2-0006 WELD SUR 213 SOCKT 1 09-Nov-04 ELBOW TO PIPE SOCKET WELD B9.40 lSI NP-2-0017 WELD SUR 213 SOCKT 1 10-Nov-04 ELBOW TO PIPE SOCKT B9.40 lSI NP-2-0018 WELD SUR 213 SOCKT 1 10-Nov-04 PIPE-TO-ELBOW SOCKT Page 4 of))
Wednesday, 09, 2005 February09, Wednesday, February 2005 Page4 of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION l.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNElT SQUARE, PA 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, 5.COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE lR20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: BJ B9.40 ISI RHC-2-0032 WELD SUR 216 SOCKT 1 11-Nov-04 ELBOW TO PIPE SOCKT B9.40 lSI NG-D-0024 WELD SUR 223 SOCKT 1 06-Nov-04 PIPE TO ELBOW B9.40 ISi NG-D-0032 WELD SUR 223 SOCKT 1 07-Nov-04 VALVE V-37-0044 TO PIPE B9.40 I5 NG-E-0039 WELD SUR 223 SOCKT 1 09-Nov-04 PIPE TO PIPE __________
B9.40 lSI MS-9-0001 WELD SUR 411 SOCKT 1 07-Nov-04 NOZZLE TO PIPE SOCKT CATEGORY: B-K B10.20 iSI 211-BP-NE-5-Hl-0057 WELD ATT SUR 211 VAR 1 19-Nov-04 NE-5-10" VARIABLE SPRING PIPE HANG B10.20 ISI 211-BP-NE-5-H2-0038 WELD ATT SUR 211 VAR 1 19-Nov-04 NE-S-10" VARIABLE SPRING PIPE HANG B10.20 ISI 211-BP-NE-5-H5-0059 WELD ATT SUR 211 FRAME 1 11-Nov-04 FRAME (NE-5-HlA)
CATEGORY: B-N-1 B13.10 I5 NRO2 INTERNAL VESSEL VT-3 222 1 11-Nov-04 RX VESSEL INTERIOR SURFACES CATEGORY: B-N-2 B13.20 ISI NRO2 587-03-A WELDED A VT-i 222 1 11-Nov-04 TOP GUIDE BRACKET B13.30 Is[ NRO2 587-01-A WELDED AT VT-3 222 1 11-Nov-04 STEAM DRYER LUG Page S of))
Wednesday, February09, Wednesday, 2005 09, 2005 PageS of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION l.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, 5.COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: B-N-2 B13.30 ISI NR02 587-01-B WELDED AT VT-3 222 1 11-Nov-04 STEAM DRYER LUG B13.30 ISI NRO2 587-01-C WELDED AT VT-3 222 1 11-Nov-04 STEAM DRYER LUG B13.30 ISI NRO2 587-01-D WELDED AT VT-3 222 1 11-Nov-04 STEAM DRYER LUG B13.30 I5 NRO2 587-02-A WELDED A VT-3 222 1 11-Nov-04 STEAM DRYER BRACKET COLLAR B13.30 ISI NRO2 587-02-B WELDED A VT-3 222 1 11-Nov-04 STEAM DRYER BRACKET COLLAR B13.30 ISI NRO2 587-02-C WELDED A VT-3 222 1 11-Nov-04 STEAM DRYER BRACKET COLLAR B13.30 ISI NRO2 587-02-D WELDED A VT-3 222 1 11-Nov-04 STEAM DRYER BRACKET COLLAR B13.30 lSI NRO2 587-04-Al WELDED VT-3 222 1 11-Nov-04 FEDWATER SPARGER BRACKET B13.30 ISI NRO2 587-04-Cl WELDED VT-3 222 1 11-Nov-04 FEDWATER SPARGER BRACKET CATEGORY: C-C C3.10 ISI 241-BP-NQZ-T-H1(P-0111 WELD AT SUR 241 SLIDE 2 05-Nov-04 SLIDE (NQZ-1-H12)
C3.20 ISI 212-BP-NZ-2-H7-0014 WELD ATT SUR 212 VAR 2 02-Nov-04 VARIABLE SPRING HANGER (NZ-2-H9)
C3.20 ISI 241-BP-NQ-2-H35-0060 WELD ATT SUR 241 VAR 2 03-Nov-04 VARIABLE SPRING HANGER (NQ-2-H19 C3.20 ISI 241-BP-NQ-2-H51-0090 WELD ATT SUR 241 VAR 2 05-Nov-04 VARIABLE SPRING HANGER (NQ-2-H8)
Wednesday, February09, 2005 Page 6 of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT' SQUARE, PA 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, 5.COMMERCIAL SERVICE DATE: 12/23/1%9 ROUTF 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE IR20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: C-C C3.20 ISI 241-BP-NQ-2-H56-0036 WELD ATT SUR 241 VAR 2 27-Oct-04 VARIABLE SPRING HANGER (NQ-2-H38 ..._.........
CATEGORY: C-F-i C5.11 ISI NE-1-0233 WELD UT 211 CIRC 2 12-Nov-04 PIPE TO PIPE STEAM SIDE C5.11 ISI NE-1-0234 WELD UT 211 CIRC 2 12-Nov-04 PIPE TO PIPE STEAM SIDE C5.11 ISI NE-1-217 WELD UT 211 CIRC 2 14-Nov-04 PIPE TO PIPE C5.11 iSi NE-1-227 WELD UT 211 CIRC 2 12-Nov-04 PIPE TO PIPE C5.11 i -- NE-2-212 WELD UT 211 CIRC 2 12-Nov-04 PIPE TO PIPE CATEGORY: C-F-2 C5.51 ISI NZ-1-0058 WELD UT 212 CIRC 2 14-Nov-04 ELBOW TO PIPE C5.51 ISI NZ-1-0058 WELD SUR 212 CIRC 2 14-Nov-04 ELBOW TO PIPE C5.51 ISi NZ-1-0059 WELD SUR 212 CIRC 2 14-Nov-04 PIPE TO ELBOW C5.51 ISI NZ-1-0059 WELD UT 212 CIRC 2 14-Nov-04 PIPE TO ELBOW C5.51 - 51 NCS-2-0025 WELD UT 225 CIRC 2 03-Nov-04 PIPE TO ELBOW C5.51 5lS NCS-2-0025 WELD SUR 225 CIRC 2 03-Nov-04 edn day .PIPE Feb yTO ELBOW .... .905
.P.. .. . g of Wednesday, February09, 2005 Page 7 of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION 1.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 4.0WNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, 5.COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: C-F-2 C5.51 ISI NQ-2-0031 WELD UT 241 CIRC 2 01-Nov-04 PIPE TO FLANGE C5.51 IS1 NQ-2-0031 WELD SUR 241 CIRC 2 01-Nov-04 PIPE TO FLANGE C5.51 ISI NQ-2-0035 WELD SUR 241 CIRC 2 01-Nov-04 PIPE TO FLANGE C5.51 ISI NQ-2-0035 WELD UT 241 CIRC 2 01-Nov-04 PIPE TO FLANGE C5.51 ISI NQ-2-0081 WELD UT 241 CIRC 2 02-Nov-04 PIPE TO ELBOW C5.51 ISI NQ-2-0081 WELD SUR 241 CIRC 2 02-Nov-04 PIPE TO ELBOW C5.51 ISI NQ-2-0088 WELD UT 241 CIRC 2 01-Nov-04 FLANGE TO PIPE C5.51 ISI NQ-2-0088 WELD SUR 241 CIRC 2 01-Nov-04 FLANGE TO PIPE 05.51 ISI NQ-2-0094 WELD UT 241 CIRC 2 01-Nov-04 FLANGE TO PIPE C5.51 ISI NQ-2-0094 WELD SUR 241 CIRC 2 01-Nov-04 FLANGE TO PIPE C5.51 ISI NQ-2-0115 WELD UT 241 CIRC 2 03-Nov-04 ELBOW TO PIPE C5.51 ISI NQ-2-0115 WELD SUR 241 CIRC 2 03-Nov-04 ELBOW TO PIPE C5.51 ISI NQZ-1-0014 WELD UT 241 CIRC 2 13-Nov-04 PIPE TO PIPE Page 8 of))
Wednesday, 09, 2005 February09, Wednesday, February 2005 Page 8 of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION l.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, 5.COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: C-F-2 C5.51 lSI NQZ-1-0014 WELD SUR 241 CIRC 2 13-Nov-04 PIPE TO PIPE C5.51 lSI RF-2-0061 WELD UT 422 CIRC 2 12-Nov-04 PIPE TO ELBOW C5.51 ISI RF-2-0061 WELD SUR 422 CIRC 2 12-Nov-04 PIPE TO ELBOW C5.90 AUG NZ-1-0062A WELD UT 212 ATACH 2 14-Nov-04 PIPE TO FLANGE SHIELD C5.90 AUG NZ-1-0062A WELD SUR 212 ATACH 2 14-Nov-04 PIPE TO FLANGE SHIELD C5.90 AUG NZ-2-0001 WELD UT 212 CIRC 2 03-Nov-04 FLANGE TO PIPE _
C5.90 AUG NZ-2-0001 WELD SUR 212 CIRC 2 03-Nov-04 FLANGE TO PIPE C5.90 AUG NQ-2-0215 WELD SUR 241 BRNCH 2 03-Nov-04 BRANCH TO PIPE CATEGORY: F-A F1.10 ISI 211-BP-634-R13-0023 SUPPORT VT-3 211 MSNUB 1 09-Nov-04 NE-2-10" MECHANICAL PIPE SNUBBER (
F1.10 ISI 211-BP-634-R6-0012 SUPPORT VT-3 211 HSNUB 2 16-Nov-04 NE-2-8" HYDRAULIC PIPE SNUBBER (N F1.10 ISI 211-BP-NE-5-H3-0060 SUPPORT VT-3 211 VAR 1 07-Nov-04 VARIABLE SPRING HANGER (NE-5-H3)
F1.10 ISI 211-BP-NE-5-H5-0059 SUPPORT VT-3 211 FRAME 1 11-Nov-04 FRAME (NE-5-H1A)
F1.10 ISI 211-BP-X-3B-SS-2-0041 A SUPPORT VT-3 211 HSNUB 1 04-Nov-04 REFER TO 21 1-BP-X-3B-SS-2-0041 Wednesday, February09, 2005 Page 9 of 11
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION l.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNETT SQUARE, PA 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, &.COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: F-A F1.10 ISI 212-BP-461-R2-0051 SUPPORT VT-3 212 MSNUB 1 09-Nov-04 MECHANICAL SNUBBER (NZ-3-S8)
F1.10 5lS 213-BP-150B-0009 SUPPORT VT-3 213 UBOLT I 10-Nov-04 U-BOLT (NP-2-H6) ---
F1.10 Isl 214-BP-556-R2-0002 SUPPORT VT-3 214 MSNUB 1 07-Nov-04 MECHANICAL SNUBBER (NU-1-S1)
F1.10 lS 215-BR-ND-10-R2-0002 SUPPORT VT-3 215 FRAME 1 07-Nov-04 GUIDE (ND-10-H2)
F1.10 ISI 223-GR-H6(D)-0040 SUPPORT VT-3 223 VAR 1 07-Nov-04 VARIABLE (NG-D-H12) . .......... . . .. ..... _._. ...... ..... ... . ....
F1.10 ISI 223-GR-H6(E)0051 SUPPORT VT-3 223 VAR 1 06-Nov-04 VARIABLE (NG-E-H112)
F1.10 ISI 223-GR-SB-1(A)(A)-0003A SUPPORT VT-3 223 SWYBR 1 05-Nov-04 SWAY BRACE (NG-A-S8)
F1.10 ISI 223-GR-SB-1 (A)(A)-0003B SUPPORT VT-3 223 SWYBR I 05-Nov-04 SWAY BRACE (NG-A-S9)
F1.20 lSI 211-BP-634-R12-0020 SUPPORT VT-3 211 HSNUB 2 26-Oct-04 NE-2-8" HYDRAULIC PIPE SNUBBER (N F1.20 I5 212-BP-NZ-2-H21-0087 SUPPORT VT-3 212 ROD 2 29-Oct-04 ROD HANGER (NZ-2-H33)
F1.20 lSI 212-BP-NZ-2-H28-0059 SUPPORT VT-3 212 VAR 2 02-Nov-04 VARIABLE SPRING HANGER (NZ-2-H47 Fi.20 [SI 212-BP-NZ-2-H7-0014 SUPPORT VT-3 212 VAR 2 02-Nov-04 VARIABLE SPRING HANGER (NZ-2-H9)
F1.20 ISI 225-SN-PSST-036-2-0026 SUPPOR VT-3 225 RGDST 2 26-Oct-04 RIGID STRUT (NCS-2-H 19)
Page 10 of 1)
Wednesday, 09, 2005 February09, Wednesday, February 2005 Page 10 of ]1
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION l.OWNER: AMERGEN ENERGY CO. L.L.C. 200 EXELON WAY, KENNElT SQUARE, PA 4.0WNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK GENERATING STATION, 5.COMMERCIAL SERVICE DATE: 12/23/1969 ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ 08731 6.NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14895 3.UNIT: OYSTER CREEK GENERATING STATION OUTAGE 1R20 TABLE 1- ISI Program ITEM REQMNT COMPONENT ID. EXAM NO COMPONENT DESCRIPTION METHOD SYSTEM TYPE CODE CLASS DATE CATEGORY: F-A F1.20 lSI 241-BP-NQ-2-H15-0015 A SUPPOR VT-3 241 ROD 2 09-Nov-04 ROD HANGER (NQ-2-H57)
F1.20 iSi 241-BP-NQ-2-H15-0015 B SUPPOR VT-3 241 ROD 2 09-Nov-04 ROD HANGER (NQ-2-H72)
F1.20 lSI 241-BP-NQ-2-H56-0036 SUPPORT VT-3 241 VAR 2 27-Oct-04 VARIABLE SPRING HANGER (NQ-2-H38 F1.20 ISI 422-1007 SUPPORT VT-3 422 VAR 2 06-Nov-04 (RF-2-H 18)
F1.20 ISI 422-1009 SUPPORT VT-3 422 VAR 2 12-Nov-04 VARIABLE (RF-2-H22)
_ ~~~~~. ......._.__.
F1.20 ISI 541-1004 SUPPORT VT-3 541 ANCHR 2 06-Nov-04 ANCHOR (CC-3-H1D)
F1.40 ISI 211-0123 V-14-33 SUPPOR VT-3 211 VAR 1 10-Nov-04 VARIABLE SPRING HANGER ON V-14-00 F1.40 ISI 214-BR-H0303-0032 V-1 7-206 SUPPO VT-3 214 VAR 1 26-Oct-04 VARIABLE SPRING HANGER ON VALV F1.40 ISI 223-GR-SS-1(C)0031 A PUMP SUP VT-3 223 MSNUB 1 05-Nov-04 MECHANICAL SNUBBER (NG-C-S3)
F1.40 ISI 223-GR-SS-1(C)0031 B PUMP SUP VT-3 223 MSNUB 1 05-Nov-04 MECHANICAL SNUBBER (NG-C-S4)__
F1.40 ISI 223-GR-SS-2(C)0032 A PUMP SUP VT-3 223 MSNUB 1 05-Nov-04 MECHANICAL SNUBBER (NG-C-S5)
F1.40 ISI 223-GR-SS-2(C-0032 B PUMP SUP VT-3 223 MSNUB 1 05-Nov-04 MECHANICAL SNUBBER (NG-C-S6)
Page IIof II Wednesday, 09, 2005 February 09, Wednesday, February 2005 Page 11 of 11
TABLE 2 Oyster Creek Generating Station ISI / IVVI Corrective Measures Component Deficiency References Disposition Dryer Tie Bar Small Indication observed 02004-3498 Eng Evaluation approved Repair Area from repair area ECR 04-00955 disposition for 1 cycle.
Dryer Lifting Lugs Small Indications observed 02004-3536 Eng Evaluation approved use-as-is on Lock welds ECR 04-00955 disposition.
SRM / IRM Dry Dry Tubes observed to be 02004-3694 One of three bowed dry tubes is a Tubes Bowed ECR 04-00988 known existing condition.
Top Guide VT-6 Indication reported 02004-3747 Previous condition still bounded by smaller than previous SIR-04-138 existing flaw evaluation.
inspection Top Guide Small Gauge observed in 02004-3751 Engineering analysis of a UT location 26-07 on Top guide SIR-04-138 detected indication located in the same cell as the gouge bounds the condition.
CSHX #2 Pressure boundary leakage 02004-1153 Weld repair completed.
identified A/R A2088856 Eval A2088856-03 Core Spray Supports 212-0019, 212- 02004-3341 Spring can supports were reset to Support 0024 & 212-0026 as-found acceptable range.
spring settings found outside (below) the acceptable tolerance range Core Spray Core Spray pipe support 02004-3311 This trapeze rod hanger was reset System I Piping 212-0018 found loose (rods to carry the proper load.
support not in tension).
212-018 1R20 Nuclear During the 1 R20 NSSS 02004-3946 Technical Evaluation Steam Supply Leak Test - Recordable A2084642-09 addressed the Bolted System (NSSS) Indications of leakage Flange leakage on CRDs in Leak Results were identified accordance with N-566-1
TABLE 3 STATISTICS FOR ISI EXAMINATIONS Number of Exams Completed Period 1 CATEGORY TOTAL 1R20 PERCENT B-A 40 3 B-D 48 12 B-F 49 11 B-G-1 22 3 B-G-2 13 6 B-J 199 34 B-K 29 4 B-N-1 3 1 B-N-2 32 11 C-C 26 5 C-F-1 29 5 C-F-2 81 28 F-A 160 40 Total 731 163 22%
TABLE 4 ISI LIMITED COVERAGE EXAMS Category Item No. Component ID Method Percent Description ___________ Coverage B-A B1.40 NRO2 1-574 WELD UT 58%
REACTOR HEAD TO FLANGE B-D B3.100 NRO2 3-576 WELD-INNER RADIUS UT 88%
N7B CLOSURE HEAD NOZZLE B-D B3.100 NRO2 1-576 WELD-INNER RADIUS UT 74%
N7A CLOSURE HEAD NOZZLE B-D B3.100 NRO2 2-566A WELD-INNER RADIUS UT 79%
N5A ISOLATION COND NOZZLE B-D B3.100 NRO2 2-566B WELD-INNER RADIUS UT 69%
N5B ISOLATION COND NOZZLE B-D B3.90 NRO2 2-566A WELD-INNER RADIUS UT 29%
N5A ISOLATION COND NOZZLE B-D B3.90 NRO2 2-566B WELD-INNER RADIUS UT 22%
N5B ISOLATION COND NOZZLE B-D B3.90 NRO2 3-565C WELD UT 22%
NIC RECIRC OUTLET NOZZLE B-D B3.90 NRO2 3-565D WELD UT 22%
N1 D RECIRC OUTLET NOZZLE B-D B3.90 NRO2 1-576 WELD UT 76%
N7A CLOSURE HEAD NOZZLE B-D B3.90 NRO2 3-576 WELD-INNER RADIUS UT 78%
N7B CLOSURE HEAD NOZZLE B-F B5.10 NRO2 4-565D WELD UT 70%
N1 D RECIRC OUTLET NOZZLE SAFE END B-K B10.10 221-0503 B WELD ATTACHMENT SUR PT 35%
RX HORIZ STABILIZER VT 65%
C-F-2 C5.90 NQ-2-0215 WELD UT 25%
6" BRANCH TO PIPE B-J B9.11 NE-5-0002 WELD UT 50%
SAFE END TO ELBOW (N5B)
B-J B9.11 NE-5-0022A WELD UT 50%
SAFE END TO ELBOW (N5A)
B-J B9.11 NG-D-0002 WELD UT 50° ELBOW TO PIPE __ _
TABLE 5 PRESSURE TESTING RESULTS The 1R20 class 1 pressure test was completed satisfactorily on 11/19/04 (R2032133). The following is a list of periodic pressure tests conducted since 1R1 9. All tests were satisfactory.
SYSTEM CLASS PM TASK WO# COMPLETE ESW 1 3 PMVTOO05 R0805177 4/12/2004 LIQUID POISON 2 PMVTOO07 R0805179 3/30/2004 CORE SPRAY 1 2 PMVTOO01 R0805173 2/20/2004 RBCCW TO SD CLG 3 PMVTOO04 R0805176 5/29/2004 AUG FUEL POOL 3 PMVT0011 R0805183 1/12/2005 RBCCW TO AFPC 3 PMVTO014 R2037578 1/12/2005 SD COOLING 2 PMVT0003 R2026577 10/21/2002 MAIN STEAM 2 PMVTOO13 R2025617 12/3/2004 FEEDWATER 2 PMVT0009 R2026873 10/27/2002
Attachment 2 Form NIS-1 for Containment ISI Program - IWE
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1. Owner AmerGen Energy Co. L.L.C., 200 Exelon Way, Kennett Square, PA 19348 (Name and Address of Owner)
- 2. Plant Oyster Creek Generating Station, Route 9 South, Forked River, NJ 08731 (Name and Address of Plant)
- 3. Unit Unit I 4. Owner Certificate of Authorization (if required) N/A
- 5. Commercial Service Date 12/23/69 6. National Board Number for Unit Reactor Vessel 14895
Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No. Providence No. Board No.
Primary Chicago Bridge & Iron Co.
Containment Vessel (Drywell and Torus) 4 I 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 + 9 4 4 + 4
- 4 +
- Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 in. x 11 in., (2) information in items I through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets recorded at the top of this form.
FORM NIS-1 (back)
- 8. Examination Dates 10/28/02 to 11/22/04
- 9. Inspection Period Identification: Second Period
- 10. Inspection Interval Identification: First Inspection Interval
- 11. Applicable Editions for Section XI 1992 Addenda 1992
- 12. Date / Revision of Inspection Plan: 12/31/01 Rev. 1
- 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See attached
- 14. Abstract of Results of Examinations and Tests. See attached
- 15. Abstract of Corrective Measures. See attached We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl, and c) corrective measures taken conform to the rules of the ASME Code, Section Xl.
Certificate of Authorization No. (if applicable) None Expiration Date N/A Date 2 q 105 Signed AmerGen Energy Co., L.L.C. Jr(
BY9vY1 S F X6 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of New Jersey and employed SB of 5T have inspected the components described in this Owners' Data Report during the period t state that to the best of my knowledge and belief, the Owner has performed examinations and ta en 6orrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Date Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of nd arising from or connected with this inspection.
v Commissions NB 9364 (1) (N) NJ766 Inspect Signatu National Board, State, Province and No.
Date Z I//l /2005 f /(
FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS Form NIS-1 for Containment ISI Program - IWE
- 13. Abstract of Examinations and Tests Oyster Creek is at the end of the second period of the first inspection internal for containment inspections. These examinations were performed to fulfill the requirements of ASME Section Xl, 1992 Edition with 1992 Addenda. Examinations were performed on all accessible areas of the interior and exterior of the drywell and torus suppression chamber. The augmented examination of the drywell liner and exterior sand bed area was also performed.
A list identifying the components inspected has been attached as Table 1.
- 14. Abstract of Results of Examinations and Tests Two (2) examinations resulted in recordable conditions and CAPs were initiated. A weld rod was found stuck to the underside of the Drywell head and reported on CAP 02004-3437. A loose locknut was identified on a spare drywell penetration and reported on CAP 02004-3586.
- 15. Abstract of Corrective Measures The weld rod that was found stuck (welded) to the underside of the drywell head was visually examined and no indications were found in the area of the arc strike. An engineering evaluation was performed (C2007833-04) that dispositioned the weld rod as use-as-is. This weld rod appeared to be from plant construction. The loose locknut did not affect the seal of the penetration and was reported to maintenance to be tightened.
NIS-1 OWNER DATA REPORT FOR INSERVICE INSPECTION l.OWNER: AMERGEN ENERGY CO. LLC. 200 EXELON WAY, KENNETT SQUARE, PA 4.OWNER CERTIFICATION OF AUTHORIZATION (IF REQUIRED): NONE 2.PLANT: OYSTER CREEK NUCLEAR GENERATING STATION, S COMMERCIAL SERVICE DATE: 12/23/190 ON ROUTE 9, TWO MILES SOUTH OF FORKED RIVER, NJ Ot731 6NATIONAL BOARD NUMBER FOR UNIT REACTOR VESSEL: 14595 3.UNIT: OYSTER CREEK NUCLEAR GENERATING STATION OUTAGE 1R20 TABLE 1- Containment ISI Program - IWE ITEM COMPONENTID EXAM NO DESCRIPTION METHOD SYSTEM TYPE CODE DATE E1.11 NROI VESSEL VT-G 187 MC 11/3/2004 DRYWELL E1.11 NRO1 HEAD VESSEL VT-G 187 MC 11/312004 DRYWELL HEAD E1.11 TORUS VESSEL VT-G 187 MC 11/7/2004 TORUS SUPPRESSION CHAMBER E1.11 X-001 PENETR VT-G 245 MECH MC 11/5/2004 DRYWELL PERSONNEL AIRLOCK& EQUIPMENT HATCH E1.11 X-002A PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FORAMAIN STEAM PIPING (S49)
E1.11 X-002B PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR'8MAIN STEAM PIPING (849)
E1.11 X-003A PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETR FOR EMERGYCONDENSER STEAM SUPPLY E1.11 X-0038 PENETR VT-O 244 MECH MC 11/5/2004 PIPING PENETR FOR EMERGYCONDENSER STEAM SUPPLY E1.11 X-004A PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR RXFEEDWATER SYSTEM (8W0)
E1.11 X-M4I PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR RXFEEDWATER SYSTEM (S.50)
E1.11 X-005A PENETR VT-3 244 MECH MC 11/5/2004 PIPING PENETRATION FOR EMERGENCY CONDNSR RETURN Page loll?
Wednesday, February02,2005 Wedhadiiy, February 02,2005 page I Of 17
ITEM COMPONENTID METHOD SYSTEM TYPE CODE DATE NO DESCRIPTION DA E1.11 X-0055 PENETR VTG 244 MECH MC 11/512004 PIPING PENETRATION FOR EMERGENCY CONDNSR RETURN E1.11 X-006 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR LIQUID POISON SYSTEM E1.11 X-007 PENETR VT-G 244 MECH MC 11/512004 PIPING PENETRATION FOR SHUTDOWN COOLING SUPPLY E1.11 X-008 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR SHUTDOWN COOLING RETURN E1.11 X-009 PENETR VT-G 244 MECH MC 11/512004 PIPING PENETRATION FOR RWCLEANUP RETURN SYSTEM E1.11 X.010 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR RWCLEANUP SUPPLY SYSYTEM E1.11 X-011 PENETR VT-G 774 ELEC MC 11/5.2004 ELECT.PENETRATION #59 FORRECIRCULATION PUMPS E1.11 X-012A PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR REACTOR LEVEL INDICATORS E1.11 X-012B PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR CORE SPRAY SUPPLY EI.11 X-013A PENETR VT-G 244 MECH MC 1/5/2004 PIPING PENETR.FOR CONTROLROD DRIVE WITHDRAW/INSERT EI.11 X-013B PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETR.FOR CONTROLROD DRIVE WITHDRAW/NSERT E1.11 X-014A PENETR VT.G 244 MECH MC 11/512004 PIPING PENETR.FOR CONTROLROD DRIVE WITHDRAW/INSERT E1.11 X-014B PENETR VT.G 244 MECH MC 11/5/2004 PIPING PENETR.FOR CONTROLROD DRIVE WITHDRAWANSERT E1.11 X-015 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR INSTRUMENT AIR Wednesday, February02, 2005 Page2 of 17
ITNEM COMPONENTID METHOD SYSTEM TYPE CODE EXDA DESCRIPTION DATE E1.11 X-016 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR DW OXYGEN SAMPLE LINE E1.11 X-017 A PENETR VT-G 244 MC 11/512004 PIPING PENETRATION (ABANDONED)
E1.11 X-017 B PENETR VT-G 244 MC 1115/2004 PIPING PENETRATION (ABANDONED)
E1.11 X-018 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETR FOR DRYWELLPURGE VENTILATION INTAKE tl .11 A-U1lu rJNr vi-U "4I4 Mr-%o Mv; 1 1 ID1IUU4 PIPING PENETR FOR DRYWELLPURGE VENTILATION EXHAUST E1.11 X4020A PENETR VT.G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR DWCLOSED COOLING WTR SUPPLY E1.11 X-020B PENETR VT.G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR DWCLOSED COOLING SUPPLY E1 .11 X-021 PENETR VT.G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR DWEDT &SUMP DISCHARGE E1.11 X-022A PENETR VT.G 244 MECH MC 11/8/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS
_g E1.11 X-022B PENETR VT-G 244 MECH MC 11/6/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-022C PENETR VT-a 244 MECH MC 1168/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-022D PENETR VT-G 244 MECH MC 11/682004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-022E PENETR VT-G 244 MECH MC 11/8/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-022F PENETR VT.G 244 MECH MC 11/8/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS Wednesday, February Wednesday, February 02, 02,2005 2005 Page3efl7 Page3 of 17
ITEM COMPONENTID METHOD SYSTEM TYPE CODE EXAM NO DESCRIPTION DATE Ei.11 X-022G PENETR VT-G 244 MECH MC 11/6/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-023 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR DEMINERALIZED WATER E1.11 X-024 A PENETR VT-G 774 ELEC MC 11/512004 ELECT. PENETRATION #3 FORRECIRCULATION PUMPS E1.11 X-024 B PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #20 FORRECIRCULATION PUMPS E1.11 X-024 C PENETR VT-G 774 SPARE MC 11/5/2004 ELECTRICAL PENETRATION - (ABANDONED)
E1.11 X-024 D PENETR VT.G 774 ELEC MC 1115/2004 ELECT.PENETRATION #53 FORRECIRCULATION PUMPS El.11 X-024 E PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #58 FORRECIRCULATION PUMPS E1.11 X-025 PENETR VT-G 244 INSTR MC 1115/2004 PIPING PENETRATION FOR HIPRESS SEAL LEAK DETECTION E1.11 X-026 PENETR VT-G 774 SPARE MC 11/5/2004 ELECTRICAL PENETRATION #7SPARE E1.11 X-027 A PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #10 FORVALVE OPERATORS E1.11 X-027 B PENETR VT-G 774 ELEC MC 11/512004 ELECT.PENETRATION #13 FORVALVE OPERATORS E1.11 X-027 C PENETR VT-G 774 ELEC MC 11/512004 ELECT.PENETRATION #18 FORVALVE OPERATORS E1.11 X-027 D PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #19 FORVALVE OPERATORS E1.11 X-028 A PENETR vr-o 774 ELEC MC 11/5/2004 ELECT.PENETRATION #46 FORCONTROL ROD POSITION IND.
Wensdy Fbar0225Pge4f7 Wednesday, February02,2005 Page 4 of 17
ITEM COMPONENT ID EXAM NO CRIPTIN METHOD SYSTEM TYPE CODE DAT NO DESCR[P77ON .DATE E1.11 X-028 B PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #49 FORCONTROL ROD POSITION IND.
Ei.11 X-028 C PENETR VT-G 774 ELEC MC 1115/2004 ELECTRICAL PENETRATION#52SPARE WITH TEMPORARY CAP E1.11 X-028 D PENETR VT-G 774 ELEC MC 11/512004 ELECTRICAL PENETRATION#56SPARE WITH TEMPORARY CAP E1.11 X029 A PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #45 FORCONTROL ROD POSITION IND.
E1.11 X4029 B PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #48 FORCONTROL ROD POSITION IND.
EI.1 X-029 C PENETR VT4. 774 SPARE MC 11/5/2004 ELECTRICAL PENETRATION#51SPARE WITH TEMPORARY CAP E1.11 X-029 D PENETR VT.G 774 SPARE Mc 11/5/2004 ELECTRICAL PENETRATION#55SPARE WITH TEMPORARY CAP E1.11 X-031 A PENETR VT-G 774 ELEC Mc 11/5/2004 ELECT. PENETRATION #9 FORTHERMOCOUPLE CABLE E1.11 X-031 B PENETR VT-G 774 ELEC Mc 11/512004 ELECT.PENETRATION #12 FORMISCELLANEOUS CABLE E1.1 I X-031 C PENETR VT-G 774 ELEC Mc 11/5/2004 ELECT.PENETRATION #15 FORCONTROL ROD POSITION IND.
E1.11 X-031 D PENETR VT-C 774 ELEC Mc 11/5/2004 ELECT.PENETRATION #17 FORCONTROL ROD POSITION IND, E1.11 X-031 E PENETR VT.G 774 ELEC MC 11/5r2004 ELECT. PENETRATION #8 FORMISCELLANEOUS CABLE E1.11 X-031 F PENETR VT-C 774 ELEC MC 11/52m04 ELECT.PENETRATION #11 FORMISCELLANEOUS CABLE E1.11 X-031 G PENETR VT-G 774 ELEC MC 11/512004 ELECT.PENETRATION #14 FORCONTROL ROD POSITION IND.
edesday,Fbrar 02, 2005e-----
Wednesday, February02, 2005 Page 5 of 17
ITEM COMPONENTID EXAM NO DSRITO METHOD SYSTEM TYPE CODE DT NO DESCRIPTION DATE E1.11 X-031 H PENETR VT-G 774 ELEC MC 11/512004 ELECT.PENETRATION #16 FORCONTROL ROD POSmON IND.
E1.11 X-032 A PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #27 FORPRM COAXIAL CABLE E1.11 X-032 B PENETR VT.G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #30 FORPRM COAXIAL CABLE E1.11 X-032 C PENETR VT-G 774 ELEC MC 11/5/2004 ELECTRICAL PENETRATION#33SPARE WITH TEMPORARY CAP E1.11 X-032 D PENETR VT.G 774 SPARE MC 11/5/2004 ELECTRICAL PENETRATION#36SPARE WITH TEMPORARY CAP E1.11 X-032 E PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #22 FORSRM/IRM TRIAXIAL CABLE E1.11 X-032 F PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #24 FORPRM COAXIAL CABLE E1.11 X-032 G PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #26 FORPRM COAXIAL CABLE E1.11 X-032 H PENETR VT-G 774 SPARE MC 11/5/2004 ELECTRICAL PENETRATION#29SPARE WITH TEMPORARY CAP Et.11 X-032 I PENETR VT-G 774 SPARE MC 11/5/2004 ELECTRICAL PENETRATION#32SPARE WITH TEMPORARY CAP E1.11 X.032 J PENETR VT-a 774 ELEC MC 11/512004 ELECT.PENETRATION #35 FORPRM COAXIAL CABLE E1.11 X-032 K PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #38 FORPRM PRM COAXIAL CABLE E1.11 X-032 L PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #41 FORSRM/IRM TRIAXIAL CABLE E1.11 X-032 M PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #21 FORPRM COAXIAL CABLE Wednesday, F.rur 0220 rWededy . .___..P................... .._._f.:.7
. .:e....
February02,2005 PWc 6 of 17
ITEM COMPONENTID EXAM NO CRMPTIO METHOD SYSTEM TYPE CODE DATE
° DESCRIPTION DT E1.11 X-032 N PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #23 FORPRM COAXIAL CABLE E1.11 X4032 P PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #25 FORPRM COAXIAL CABLE E1.11 X-032 0 PENETR VT-G 774 SPARE MC 11/5/2004 ELECTRICAL PENETRATION#28SPARE WITH TEMPORARY CAP E1.11 X4032 R PENETR VT-G 774 SPARE MC 11/5/2004 ELECTRICAL PENETRATION#31SPARE WITH TEMPORARY CAP E1.11 X-032 S PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #34 FORFOR PRM COAXIAL CABLE E1.11 X-032 T PENETR VT-G 774 ELEC MC 11/5/2004 ELECTRICAL PENETRATION#37FOR PRM COAXIAL CABLE E1.11 X-032 U PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #40 FORPRM COAXIAL CABLE E1.11 X-033 PENETR VT-G 774 ELEC MC 1115/2004 ELECT.PENETRATION #39 FORPRM CABLE E1.1 1 X-034 PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #42 FORPRM COAXIAL CABLE E1.11 X-036 PENETR VT-G 774 ELEC MC 11/5/2004 ELECT.PENETRATION #57 FORTHERMOCOUPLE CABLE E1.11 X-037A PENETR VT-a 774 SPARE MC 11/5/2004 ELEC.PENETRATION #1 SPARE E1.11 X-037B PENETR VT.G 774 SPARE MC 11/5/2004 ELEC.PENETRATION #1 SPARE-ABANDONED E1.11 X-037C PENETR VT-G 774 SPARE MC 11/5/2004 ELEC.PENETRATION #1 SPARE-ABANDONED E1.11 X-037D PENETR VT-G 774 SPARE MC 11/5/2004 ELEC.PENETRATION #1SPARE-WITH TEMPORARY CAP February02,2005 Wednesday, February Wednesday, 02, 2005 Page 7of 17 Page 70of 17
ITEM COMPONETID METHOD SYSTEM TYPE CODE EXAM DESCRIPTION DATE E1.11 X-038 A PENETR VT-G 244 INSTR MC 11/512004 PIPING PENETRATION FOR RXWIDE RANGE WATER LVL(TOP)
E1.11 X-038 B PENETR VT-t 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXLEVEL CONTROL(STATIC LEG)
E1.11 X-038 C PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR PROTECTION SYSTEM LEVEL E1.11 X-038 D PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR EMERGENCY CONDENSER STEAM E1.11 X-038 E PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR EMERGENCY COND.CONDENSATE E1.11 X-038 F PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXPROTECTION SYSTEM LEVEL E1.11 X-039 A PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXPROTECTION SYSTEM LEVEL E1.11 X-039 B PENETR VT.G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXLEVEL CONTROL(STATIC LEG)
E1.11 X-039 C PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXPROTECTION SYSTEM LEVEL E1.11 X-039 D ' PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR LEVEL CONTROL(LT-ID00138)
E1.11 X-040 A PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXRECIRC LOOPS D/P SUCTION E1.11 X-040 B PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXRECIRC LOOPS D/P SUCTION E1.11 X-040 C PENETR VT-G 244 INSTR MC 11/512004 PIPING PENETRATION FOR RXRECIRC LOOPS D/P SUCTION E1.11 X-040 D PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXRECIRC LOOPS D/P SUCTION February 02,2005 Wedne3day, FebeRay Wednesday, 02,20O05 Page 8 of 17 Page8 of 17
ITEM COMPONENT ID EXAM NE DESCRIPTION METHOD SYSTEM TYPE CODE DATE E1.11 X-040 E PENETR VT-G 244 INSTR MC 1115/2004 PIPING PENETRATION FOR RXRECIRC LOOPS D/P SUCTION E1.11 X-040 F PENETR VT-G 244 INSTR MC 1115/2004 PIPING PENETRATION FOR RXRECIRC LOOP D/P DISCHARGE E1.11 X-040 G PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXRECIRC LOOP D/P DISCHARGE E1.11 X-040 H . PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RECIRC.LOOP D/P DISCHARGE E1.11 X-040 I PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXRECIRC LOOP DIP DISCHARGE E1.11 X-040 J PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXRECIRC LOOP D/P DISCHARGE E1.11 X-041 A PENETR VT-G 244 MC 11/15/2004 PIPING PENETRATION (ABANDONED)
E1.11 X-041 B PENETR Vr-G 244 MC 11/5/2004 PIPING PENETRATION (ABANDONED)
E1.11 X-041 C PENETR VT-G 244 MC 11/5/2004 PIPING PENETRATION (ABANDONED)
E1.11 X-041 D PENETR VT43 244 MC 11/5/2004 PIPING PENETRATION (ABANDONED)
E1.11 X-041 E PENETR VT-G 244 MC 11/5/2004 PIPING PENETRATION (ABANDONED)
E1.11 X-041 F PENETR Vr-G 244 MC 11/5/2004 PIPING PENETRATION (ABANDONED)
E1.11 X-01 G PENETR VT-G 244 MC 11/5/20 PIPING PENETRATION (ABANDONED)
E1.11 X-041 H PENETR VT-G 244 MC 11/5/2004 PIPING PENETRATION (ABANDONED)
February 02,2005 Wednesday, Febnoory Wednesday, 02, 2005 Page 9 of 17 Page9 of 17
ITEM ITEM COMPONENT ID NO METHOD SYSTEM TYPE CODE EXAM DESCRIPTION DATE E1.11 X-041 I PENETR VT-G 244 MC 1115/2004 PIPING PENETRATION (ABANDONED)
E1.11 X-041 J PENETR VT-G 244 MC 11/5/2004 PIPING PENETRATION (ABANDONED)
E1.1I X-042 PENETR VT-G 244 INSTR MC 1115/2004 PIPING PENETR.FOR REACTORLEVEL INSTRUMENTATION E1.11 X-043 PENETR VT-G 244 SPARE MC 1115/2004 PIPING PENETRATION-SPARE E1.11 X-044 A PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION SPARE TWO TUBES WITH TEMP. CAPS E1.11 X-044 B PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION SPARE E1.11 X-045 A PENETR VT-G 244 INSTR MC 11/512004 PIPING PENETR. FOR INCORECALIBRATION MONITOR TUBE E1.11 X-045 B PENETR VT.G 244 INSTR MC 11/5/2004 PIPING PENETR.FOR INCORE CALIBRATION MONITOR TUBE E1.11 X-045 C PENETR VT-G 244 INSTR MC 111512004 PIPING PENETR.FOR STEAM FLOW NOZZLE IMPULSE LINES E1.11 X-045 D PENETR VT-O 244 INSTR MC 11/5/2004 PIPING PENETR FOR RX COREDIFF.PRESSURE INDICATION E1.11 X-045 E PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR.FOR INCORE CALIBRATION MONITOR TUBE E1.11 X-045 F PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRRFOR INCORE CALIBRATION MONITOR TUBE E1.11 X-045 0 PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR. FOR STEAM FLOW NOZZLE IMPULSE LINES E1.11 X-046 A PENETR VT-G 244 SPARI MC 11/5/2004 PIPING PENETRATION SPARE WITH PERMANENT CAP Wednesday, Wednesday, February February02,2005 02, 2005 Page 10 oJ17 Page *0 of t7
ITEM COMPONENT ID EA NO CRIPTIO METHOD SYSTEM TYPE CODE R NO DESCRIPTION DA~TE E1.11 X-046 B PENETR VT-G 244 SPARE MC 11/S/2004 PIPING PENETRATION SPARE WITH PERMANENT CAP E1.11 X-047 A PENETR VT-G 244 SPARE MC 1115/2004 PIPING PENETRATION SPARE E1.11 X-047 B PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-047 C PENETR VT.G 244 SPARE MC 11/5/2004 PIPING PENETRATION SPARE E1.11 X-047 D PENETR VT.G 244 SPARE MC 11/5/2004 PIPING PENETRATION SPARE E1.11 X4049 A PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL E1.11 X-049 B PENETR - VT.G 244 MECH MC 11/712004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL E1.1 1 X-049 C PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL E1.11 X-049 D PENETR VT.G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL E1.11 X-049 E PENETR VT-O 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL E1.11 X-049 F PENETR VT.G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL E1.11 X-049 G PENETR VT.G 244 MECH MC 1117/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRWELL E1.11 X-049 H PENETR VT.G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL E1.11 X-049 I PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL Weddoy F Wednesday, February02, 2005 Page 11 of 17
ITEM COMPONENTID METHOD SYSTEM TYPE CODE EXAM NO DESCRIPTION M DATE E1.11 X-049 i PENETR VT.a 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWVENT PIPE TO DRYWELL PIE11 X-050 A PENETR VT.G 244 INSTR MCi U
NS
..... /5200 PIPING PENEIR. FOR RECIRCPUMP 'E'SEAL CAVITY #2 E1.11 X.050 B PENETR VT-G 244 INSTR Mc 11_5/2004 PIPING PENETR. FOR RECIRCPUMP 'E'SEAL CAVITY #1 E1.11 X-050 C PENETR VT.G 244 INSTR MC 11/5/2004 PIPING PENETR. FOR RECIRCPUMP 'D'SEAL CAVITY #2 E1.11 X-050 D PENETR VT.G 244 INSTR MC 11/5/2004 PIPING PENETR. FOR RECIRCPUMP 'D SEAL CAVITY #1 E1.11 X-050 E PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR. FOR RECIRCPUMP 'C'SEAL CAVITY #2 E1.11 X-050 F PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR. FOR RECIRCPUMP 'C'SEAL CAVITY #1 E1.11 X-050 G PENETR VT- 244 INSTR MC 11(5/2004 PIPING PENETR. FOR RECIRCPUMP 'B'SEAL CAVITY #2 E1.1 I X-050 H PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR. FOR RECIRCPUMP 'B'SEAL CAVITY #1 E1.11 X-050 I PENETR VT.G 244 INSTR MC 11/5/2004 PIPING PENETR. FOR RECIRCPUMP 'A' SEAL CAVITY #2 E1.11 X-050 J PENETR VT.G 244 INSTR MC 11/5/2004 PIPING PENETR. FOR RECIRCPUMP 'A' SEAL CAVITY #1 E1.11 X-050 K - PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 L PENETR VT.G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 M PENETR VT.G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
Wednesday, February 02, 2005 Page li of 17
ITEM COMPONENT ID METHOD SYSTEM TYPE CODE EXAM NO DESCRIPTION DATE E1.11 X-050 N PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR FOR DRYWELLPRESSURE INSTRUMENTATION E1.11 X-050 P PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 0 PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 R PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 S PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 T PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E.i1 X-450 U PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 V PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 W PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 X PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 Y PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)
E1.11 X-050 Z PENETR VT.G 244 INSTR MC 11/5/2004 PIPING PENETR.FOR DRYWELLPRESSURE INSTRUMENTATION E1.11 X-051A PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-051B PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS February 02,2005 Wednfesday, February Wednesday, 02,2ioos Page 13f 17 Page13 of 17
ITEM COMPONENTID METHOD SYSTEM TYPE CODE EXAM NO DESCRIPTION DATE E1.11 X-051C PENETR VT-4 244 MECH MC 1117/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-051D PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X4051E PENETR VT-G 244 MECH MC 11//2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-051F PENETR VT-G 244 MECH MC 11/72004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-051G PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR DWTO TORUS VACUUM BREAKERS E1.11 X-052 PENETR VT-G 244 MECH MC 11/3/2004 PIPING PENETRATION ACCESS MANHOLE E1.11 X-053 A PENETR VT-G 244 MECH MC 11/6/2004 PIPING PENETRATION FOR SUPPR VESSEL ACCESS HATCH E1.11 X-053 B PENETR VT-G 244 MECH MC 1117/2004 PIPING PENETRATION FOR SUPPR VESSEL ACCESS HATCH E1.11 X-056 PENETR VT-G 244 INSTR MC 11/7/2004 PIPING PENETR. FOR TORUS PRESSURE INSTRUMENTATION Ei.11 X-057 PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR 02TORUS SAMPLE SYSTEM E1.11 X-059 PENETR VT-a 244 MECH MC 11,5/2004 PIPING PENETRATION- H2102 SAMPLE SUPPLY E1.11 X-eo A PENETR VT-G 244 MECH MC 11/512004 PIPING PENETRATION H2V02 SAMPLE RETURN E1.11 X-00 B PENETR VT-a 244 SPARE MC 11/5/2004 PIPING PENETRATION SPARE WITH PERMANENT CAP E1.11 X-060 C PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION SPARE WITH PERMANENT CAP February 02, Wednesday, February 02,2005 2005 Page I4of 17 Page 14 of 17
ITEM COMPONENTID EXAM NO DESCRIPTION METHOD SYSTEM TYPE CODE DATE V
DT E1.1 1 X-060 D PENETR VT-G 244 SPARE MC 1115/2004 PIPING PENETRATION SPARE WITH PERMANENT CAP E1.11 X-060 E PENETR VT.G 244 SPARE MC 11/5/2004 PIPING PENETRATION SPARE WITH PERMANENT CAP E1.11 X-060 F PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION H2/02 SAMPLE RETURN E1.11 X-060 G PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION H2/02 SAMPLE RETURN E1.11 X-061 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR RXCRDHS SUPPLY IN DRYWELL E1.11 X-062 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR REACTOR HEAD COOLING E1.11 X-063 A PENETR VT.G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR CONTAINMENT SPRAY SUPPLY E1.11 X-063 B PENETR VT-G 244 SPARE MC 11/5/2004 PIPING PENETRATION(SPARE)IN DRYWELL E1.1 1 X-065 PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR VACUUM BREAKER TO ATMOS.
E1.11 X-068 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR CONTAINMENT SPRAY SUPPLY E1.1 1 X-067 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION (ILRT TESTING WITH CAP)
E1.1 1 X-068A PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION TO HDR FOR PASS&CORE SPRAY SUCT.
E1.11 X-068B PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION TO HDRFOR PASS&CORE SPRAY SUCT.
E1.11 X.069 PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION TO HDRFOR PASS&CORE SPRAY SUCT.
Wednesday, February09, 2005 WednedayFebrary 0, 205 Pae 5of 1 Page *5 of 17
ITEM COMPONENTID EXAM NONO CRIPTIO DESCRIPTION METHOD SYSTEM TYPE CODE DAT DATE E1.11 X-070 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR CORE SPRAY SUPPLY SYSTEM E1.11 X-071 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR RXRECIRC LOOP SAMPLE LINE E1.11 X-072 PENETR VT-G 244 MECH MC 11/5/2004 PIPING PENETRATION FOR MSSTEAM LINE DRAIN E1.11 X-073 A PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR FOR EMERGYCONDENSER STEAM SUPPLY E1.11 X-073 B PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR EMERGENCY CONDENSER STEAM E1.11 X-073 C PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR EMERG'Y COND'R CONDENSATE E1.11 X-073 D PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETRATION FOR RXPRESSURE INSTRUMENTATION E1.11 X-074 PENETR VT-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR RWCU DEMINERALIZER RELIEF LINE E1.11 X-075 A PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR.FOR RECIRC.FLOW TRANSM IMPULSE LINE E1.11 X-075 B PENETR VT-G 244 INSTR MC 11/5/2004 PIPING PENETR.FOR RECIRC.FLOW TRANSM IMPULSE LINE E1.11 X-076A PENETR VT.G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR EMRV CONN.TO VENT PIPES E1.11 X-076B PENETR vr-G 244 MECH MC 11/7/2004 PIPING PENETRATION FOR EMRV CONN.TO VENT PIPES E1.11 X-077 PENETR VT-G 244 MECH MC 11/7/2004 DRYWELL PENETRATION FOR TORUS DRAIN, V-38-0034 E1.11 X-078 PENETR VT-G 244 INSTR MC 11/7/2004 DRYWELL PENETRATION FOR INSTRUMENTS LT 37 < 38 Pve esay rur -- ----
UJ~ ae 6of1 veanesdaly, FebruaryUY, Z,0u5 Pnge 16 of 17
ITEM COMPONENTID EXAM NO METHOD SYSTEM TYPE CODE DESCRIPTION DATE E1.1l1 X-079A PENETR VT-G 243 MC 111512004 BIO SHIELD STABILIZER MANWAY E1 .11 X-079B PENETR VT-G 243 MC 11/5/2004 BIO SHIELD STABILIZER MANWAY E1 .11 X-079C PENETR VT-G 243 MC 11/5/2004 BIO SHIELD STABILIZER MANWAY E1.11 X-079D PENETR VT-G 243 MC 11/5/2004 B10 SHIELD STABILIZER MANWAY E1.11 X-079E PENETR VT-G 243 MC 11/5/2004 B10 SHIELD STABILIZER MANWAY E1.1l1 X-079F PENETR VT.G 243 MC 11/5/2004 BIO SHIELD STABILIZER MANWAY E1.1 I X-079G PENETR VT-G 243 MC 11/5/2004 B10 SHIELD STABILIZER MANWAY E11.11 X-079H PENETR VT-G 243 MC 1115/2004 BIO SHIELD STABILIZER MANWAY Wednesday Febuay 9-- 05Pae--- 1 W~ednesday, Februar 09, 2005 Page17of 17
Attachment 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS AND REPLACEMENTS
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date February 13. 2003 Name 200 EXELON WAY. KENNETT SQUARE. PA SheetL1. . of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH. FORKED RIVER, NJ 08731 Work Order # C0550852 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energy Co LLC Type Code Symbol Stamp NIA Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date_ N/A Address
- 4. Identification of System ISOLATION CONDENSER (21 1)
- 5. (a) Applicable Construction Code 33 1.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6. Identification of Components Repaired or Replaced and Replacement Components.
- 7. Description of Work Modification of two pipe supports (211-11 and 211-12) in the Isolation Condenser system on 75 ft. Rx Bldg.
- 8. Tests Conducted NA Hydrostatic _ Pneumatic _ Nominal Operating Pressure Other Pressure psi Test Temp. 0
_ F
. , I I-NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 X 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47k" St., New York, NY 10017 AG0527 (05/01)
FORMAI NIS-2 (Back)
- 9. Remarks: This modification was to restore the piping system to design compliance with ANSI B3 1.1 for normal operating and seismic loads. The following supports were upgraded and modified in the Isolation condenser system: 211-11 and211-12.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date NIA Signed WA9/ tt; T (Owner 1Sf PIt1 or Ow er's Designee, Title 5h1AM EW6. Date FE&. -Z64h CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period4iSl0f to 1*30' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XM.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions NB 5478 (1)(N) NJ442 pors Signaturel National Board, State, Province, and Endorsements Date -AJOAiM' c 7 Ja6O i AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date February 13. 2003 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet I of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 C0511914 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energv Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY, KENNETT SOUARE. PA Expiration Date. N/A Address
- 4. Identification of System SERVICE WATER SYSTEM 531
- 5. (a) Applicable Construction Code B331.1 1955 Edition, N/A Addenda, N-416-1 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1986
- 6. Identification of Components Repaired or Replaced and Replacement Components.
- 7. Description of Work: Replace 20 x 24 x 24 pipe tee downstream of V-3-58/59 valves. Prefab the 20 x 24 x 24 tee and pipe spool.
- 8. Tests Conducted Hydrostatic X_ Pneumatic Nominal Operating Pressure Other Pressure 112 psi Test Temp. Ambient OF NOTE: Supplemental sheets in form of lists, sketches, or drawings May be used, provided (1) size is 8 '%x i 1 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47h St. , New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Replace 20 x 24 x 24 pipe tee downstream of V-3-58/59 valves. Prefab 20 x 24 x 24 tee and pipe spool.
The spools pieces in the Fab shop was hydro and the tie in welds in site was pressure tested using Code Case N-416-1.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code, Section Xl.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed YaAL&
f 4/ qr XSr owner or Ownei~s Designee, Title ff0mMA &X. Date 4/If03 I I 20 03 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period 6L 41aR0o 1'38'and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
k a -.4/ Commissions NB 5478 (1 (N) NJ442 Insptcts Signature e National Board, State, Province, and Endorsements Date _________ ___ __
AG0527 (05101)
FORM NIS-2 OWN'NER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date July 21. 2003 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet I of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name UiS ROTUTF Q 01UTHI-.FORKFDl RIVFR NJ 0871 Work Order # R2027977 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energy Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SOUARE. PA Expiration Date_ N/A Address
- 4. Identification of System SERVICE WATER SYSTEM (532)
- 5. (a) ApplicableConstruction Code B31.1 1955 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National . Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Built Replaced, or Stamped No. Replacement (Yes or No)
V-3-133 Wafer - Dual NA 001573101001 Replacement NO Plate
- 7. Description of Work Open and inspect V-3-133 check valve and replace if required. Performed bench hvdro on replacement valve prior to installation. Performed ISLT of valve after installation.
- 8. Tests Conducted Hydrostatic X Pneumatic Nominal Operating Pressure.
Other Pressure 425 psi TestTemp. ambient OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 1/2x 1 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may beobtained from the Order Dept., ASME, 345 E. 47th St. ,New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: This work was to inspect V-3-133 check valve and replace if required. The valve was replaced with a new valve. No welding was required.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed L/ I er XI f5OrfKOW Mk Owner or bwner's Designee, Title Date_ JVL'( 2 /,23 .,2003 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period -11kid, to 77j , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_a_ Commissions NB 5478 (1) (N) NJ442 t nspector's Sir- ture National Board, State, Province, and Endorsements Date / i 2003 AG0527 (05/0 1)
FORM NIS-2 ONWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energv Co L.L.C. Date May 26. 2004 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet I of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2008004 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energv Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXPLON WAY. KFNNETT S1JARR. PA Expiration Date_ N/A Address
- 4. Identification of System Containment Spray System (241)
- 5. (a) Applicable Construction Code ASME Section VIII _ Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National . Year Repaired, Code Component Manufacturer Serial No. Board Other Identification B Replaced, or Stamped No. Replacement (Yes or
__ _ __ _ _ _ _ _ _ _ _ __ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _N o)
Containment Perfex Group CSHX 1-2 Repaired Yes Spray Heat Exchanger
- 7. Description of Work: Weld repair of through-wall crack in nozzle to vessel dissimilar metal weld on CSHX 1-2.
- 8. Tests Conducted Hydrostatic - Pneumatic Nominal Operating Pressure X Other _ Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 1/2 X 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47 h St., New York, NY 10017 AG0527 (05/01)
14 FORM NIS-2 (Back)
- 9. Remarks: Through wall crack was ground out and weld repaired. Code Case N-416-2 was used as PMT.
CAP # 02004-1153. ,
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Awi~i8ir
-Ierso~oo XT Mf A Expiration Date N/A ClLI II dLV 01 %UIIVIIZa~LOIVI1N1. 11/A SZiannd 14" 7int/>-T Date MA1Y'( ICA0 , 2004-~
/ Owner or 6w;e4rDesignee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period _ to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Ad4 y36 r/l() A/ 76c(
11P -0,ze'--l-
. IrVctor'-s Siglhture Commissions ND 3478 et) Ro, J#42-National Board, State, Province, and Endorsements zO cy Datee ;Ay, I -
AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen EnerU Co L.L.C. Date December 1.2004 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet I of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2008862 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Enery Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date_ N/A Address
- 4. Identification of System Main Steam System (41 1)
- 5. (a) Applicable Construction Code ASME SectionVIII _ Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Built Replaced, or Stamped No. Bul Replacement (Yes or V-1-7 MSIV Atwood & NS03A Repaired No Morrill
- 7. Description of Work: Overhaul of internals of Main Steam Isolation Valve V-1-7 in the drywell.
- 8. Tests Conducted Hydrostatic Pneumatic Nominal Operating Pressure X Other Pressure psi Test Temp. 0F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 474 St, New York, NY 10017 AGOS27 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Valve bonnet (cover) was replaced. Valve body gas)cet surface area was weld repaired due to small indication in gasket seating area. Code Case N416-2 was used as PMT.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code, Section Xl.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed A d JDate Dp C I ,2004
/ dwner or Ownchbesignee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW. JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period 4, L to /1/*/4 d state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
.Commissions NB 9364 (1)(N) NJ766 nspecto~s Signature National Board, State, Province, and Endorsements Date 2004
. 11 , -
AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section Xl
- 1. Owner AmerGen Energv Co L.L.C. Date January 26. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA SheetI of1 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH. FORKED RIVER, NJ 08731 WO# C2008343 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Enermy Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date N/A Address
- 4. Identification of System Emergency Service Water (ESW) System (532)
- 5. (a) Applicable Construction Code ASME B3 1.1 195 Edition. N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 w/ 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
- 7. Description of Work: Replace 2 inch ESW System I keepfill line with new AL6XN material piping.
- 8. Tests Conducted Hydrostatic_ Pneumatic - Nominal Operating Pressure _X_
Other__ Pressure psi Test Temp. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 4 7 h St., New York, NY 10017 AGU527 (O5/01)
FORM NIS-2 (Back)
- 9. Remarks: Replace 2 inch ESW System I keepfill line with new AL6XN material piping. Installed 2 new replacement valves (V-3-948. V-3-698 and V-3-134) of the same material and modified three pipe supports. Refer to ECR 03-00453.-
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code, Section X1.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A A-gite . m 6wm ea) Date AQUAI-Y" X 2005 r Owner or Offler's Designee, Title F s De s-ig n e tl ev -
CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by ySB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period i dV to j4nand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
National Board, State, Province, and Endorsements Date 20n5 r ---- /
AG0527 (05101)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date January 26. 2005 Name 200 FYFLON WAY. KF.NNFTT SOUARE PA Sheet 1 of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2008344 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energy Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date_ N/A Address
- 4. Identification of System Emergencv Service Water (ESW) System (532)
- 5. (a) Applicable Construction Code ASME B31.1 1955 Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 w/ 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer NatinalYear Repaired, Code Component Manufacturer Serial No. Board Other Identification Iuilt Replaced, or Stamped CmnetNo. ui Replacement (Yes or ESW Piping Keepfill Line Replaced No Pipe Support 531-1061 Replaced No
- 7. Description of Work: Install new pipe support 531-1061 and replace 2 inch keepfill piping between V-3-941 and V 949 with new AL6XN material piping.
- 8. Tests Conducted Hydrostatic - Pneumatic Nominal Operating Pressure _X_
Other Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 x I I in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47 St., New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Install new pipe support 531-1061 and replace 2 inch keepfill piping between V-3-941 and V-3-949 with new AL6XN material piping. Refer to ECR 03-00454.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A - Expiration Date__Nl&
Signed lA PRV1M gA.
I Owner or Owfier's Designee, Title EX Date JAIYAA v r Z6' ,2005 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HS OF CT of HARTFORD, CONNECTICUT have inspected the components described in this Owner's Report during the period 71t4 to ?4YZKand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions NB 9364 (l) (N) NJ766 In or's Sigture National Board, State, Province, and Endorsements Date___ ___ _ _ 2005 AG0527 (05101)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date January 26. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet I of.2.
Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2008345 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energy Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date_ N/A Address
- 4. Identification of System Emergency Service Water (ESWM System (532)
- 5. (a) Applicable Construction Code ASME B31.1 1955 Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 w/ 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National . Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Built Replaced, or Stamped No. Replacement (Yes or N)
ESW Piping Replaced No
- 7. Description of Work: Replace 2 inch piping between V-3-941 and V-3-940 with new AL6XN material piping.
- 8. Tests Conducted Hydrostatic Pneumatic - Nominal Operating Pressure _X_
Other__ Pressure psi Test Temp. -F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 /2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
.A i (12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47"' St., New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Replace 2 inch piping between V-3-941 and V-3-940 with new AL6XN material piping, Refer to ECR 03-00455.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed !C:5rrAfS1 6-A'I6eV Date MWAJUAA{t I42005 I Owner orb~wner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period o to *L, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
1S;-Z4w Commissions NB 9364 (I) (N) NJ766 Inspthr's Signafure National Board, State, Province, and Endorsements Date ?-5. 2005
/
AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date January 18. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet I of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# R2041057 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energv Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date N/A Address
- 4. Identification of System Emergency Service Water System (532)
- 5. (a) Applicable Construction Code ASME B31.I 1955 Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 w/ 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Built Replaced, or Stamped No. Bui Replacement (Yes or Check valve V-3-133 Replaced No 4 4-
- 4 9 4 9 4 4-
- 4 9 4
- 7. Description of Work: Replaced 2" ESW keep fill check valve V-3-133 with a new valve.
- 8. Tests Conducted Hydrostatic - Pneumatic - Nominal Operating Pressure _X_
Other Pressure psi Test Temp. °F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 x 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47rh St., New York, NY 10017 AG0527(05/01)
FORM NIS-2 (Back)
- 9. Remarks: Replaced 2" ESW keep fill check valve V-3-133 with a new valve.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Si-ned ),
0 514Z a- e9066 Owner or OVner's Designee, Title AC. Dlate RUMAt(Y 4 ,2005-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the periodf//e. to W and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions NB 9364 (1)(N) NJ766 tor's ignature National Board, State, Province, and Endorsements Date 2-/'@ 2005 AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date January 18. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet 1 of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2007604 / ECR OC 03-00971 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energy Co LLC Type Code Symbol Stamp .N./&
Name Authorization No. N/A 200 EXELON WAY. KENNETT SOUARE. PA Expiration Date. N/A Address
- 4. Identification of System Rx Head Vent Cooling System (216)
- 5. (a) Applicable Construction Code ASME SectionI 1965 Edition, B31.1 1983/1984 Addenda, N-416-2 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 w/1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Built Replaced, or Stamped No. Replacement (Yes or No)
Cross-Connect System 216 Replacement No lVand 2" (modification)
Piping and Supports Restriction RO-678 Replacement No Orifice
- 7. Description of Work: Install reactor head cross-connect piping between head spray and head vent piping. Work included modification to 4 pipe supports and final VT-3 inspection of a total of 10 pipe supports. Utilized AWS Dl. I for support welding.
- 8. Tests Conducted Hydrostatic _ Pneumatic. Nominal Operating Pressure _X_
Other Pressure psi Test Temp.F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 %Ax 11 in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained frmm the Order Dept., ASME, 345 E. 417 St., New York, NY 10017 Ai00527 (OSIO1)
FORM NIS-2 (Back)
- 9. Remarks: Installed new cross-connect piping and modified 4 pipe supports associated with this modification. Performed final PT and VT-3 inspections on the piping and supports that were installed / modified. Post Maintenance Testing (PMT) performed during Reactor pressure test prior to start-up.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed 1 J
h 4M 1L Ab6. EJG.
Owner oribvner's Designee, Title Date -JrAUA t( I 2005 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSO-QEF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period /1 to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
<',-rtew-
_ =es - ,'
I-Ar y-e g Inspector'i,$gnature A
v
,,, Commissions NB 9364 (1) (N) NJ766 National Board, State, Province, and Endorsements Date_ 2005
/ f AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen EnergDCo L.L.C. Date January 10. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA SheeLtL1 of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2008993 Address Repair Organization P.O. No., Job No., ctc.
- 3. Work Performed by A-merGen Energy Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date N/A Address
- 4. Identification of System Core Spray System (212)
- 5. (a) Applicable Construction Code ASME B3 1.1 1955 Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 w/ 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Built Replaced, or Stamped No. Bi Replacement (Yes or No)
Spring Can Bergen- 212-0018 Repaired No Support Patterson
- 7. Description of Work: Repair hanger support and reset cold load setting on spring can on the Core Spray system.
- 8. Tests Conducted Hydrostatic__ Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp. F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47" St, New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Renlaced bent rod on hanger support and reset spring can cold setting. Performed VT-3 inspection.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A - Expiration Date N/A
%.,&S/yJ -n or b I51 (60tA Designee, T.i-t MA Date TAAK/AY 10t .Mne l Owner or l)Wne-r's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD, CONNECTICUT have inspected the components described in this Owner's Report during the period i/4* to w*and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
lIgaL 1--~ -Commissions NB 9364 (1) (N) NJ766 Inab sSignat National Board, State, Province, and Endorsements Date A24 2005 AGO527 (05/01)
FORM NIS-2 OWNTER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section Xl
- 1. Owner AmerGen Energy Co L.L.C. Date January 10. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet 1 of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2007392 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Enerzv Co LLC Type Code Symbol Stamp_ N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date N/A Address
- 4. Identification of System Main Steam System (41 1)
- 5. (a) Applicable Construction Code ASME SectionI. 6i% Edition, N/A Addenda, N& Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 w/ 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Built Replaced, or Stamped No. Replacement (Yes or
_ _ _ _ _ _ __ __ ___ _ _ _ _ _ _ _ _ _ _ _ _N o)
V-1-9 MSIV Atwood & NS04A Repaired No Morrill
- 7. Description of Work: Overhaul of internals of Main Steam Isolation Valve V-1-9 in the trunnion room.
- 8. Tests Conducted Hydrostatic _ Pneumatic _ Nominal Operating Pressure X Other Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 '/2 x I I in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47"' St., New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Valve bonnet (cover) was replaced and valve main seat lapped. Code Case N416-2 was used as PMT.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed L J
iMt Aj Owner or 3s1L F9069M er's Designee, Title Xag. Date VAJUAk IoU1 .2005 CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSP OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period / to Z*47and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
4&Z14p I Commissions NB 9364 (1)(N) NJ766 Inspect Signa National Board, State, Province, and Endorsements Date _ _ _ _ _ _ _ _ _
AG0527 (05101)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date January 10. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA SheetI. . of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH, FORKED RIVER, NJ 08731 WO# C2009114 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energy Co LLC Type Code Symbol Stamp N/A Name Authorization No. NLA 200 EXELON WAY. KENNETT SOUARE. PA Expiration Date N/A Address
- 4. Identification of System Reactor Building Closed Cooling Water(RBCCW) system (541)
- 5. (a) Applicable Construction Code ASME B3 1.1 1955 Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1995 w/ 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year Repaired, Code Component Manufacturer Serial No. Board Other Identification it Replaced, or Stamped No. Bui Replacement (Yes or
__ _ __ __ _ __ __ _ _ _ _ __ __ _ _ _ _ _ _ _ _ _ _ No )
RBCCW pump V-5-152 Replaced No 1-2 discharge isolation valve
- 7. Description of Work: Replace pump discharge valve V-S-I52 with a new valve.
- 8. Tests Conducted Hydrostatic _ Pneumatic _ Nominal Operating Pressure _X_
Other _ Pressure psi Test Temp. i °F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 % x II in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept, ASME, 345 E. 47"' St, New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Replace RBCCW pump 1-2 discharge isolation valve V-5-152 with new valve.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed £5 IiO6KA £ . Date JhMJAJL'Y 10A1 2005 Owner or er's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period 1 to t _* and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
IC- Commissions NB 9364 (1) (N) NJ766 Inspec,;dnatufe National Board, State, Province, and Endorsements Date 2005
- it - ,
AG0527 (05101)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section Xl
- 1. Owner AmerGen Energy Co L.L.C. Date January 10. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet- I . of 2
- Address
- 2. Plant OYSTER-CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2006437 and C2006438 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Enery Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date N/A Address
- 4. Identification of System Containment Spray (241)
- 5. (a)ApplicableConstructionCode ASME B31.1, 1983 Edition, 1984 Addenda, NA Code Case (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1995 w/1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National O Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Bilt Replaced, or Stamped No. Bi Replacement (Yes or Containment P-2 1-IA Replaced No Spray Pump Containment P-21-IB Replaced No Spray Pump
- 7. Description of Work: Replace both containment spray pumps with new Vumps.
- 8. Tests Conducted Hydrostatic__ Pneumatic Nominal Operating Pressure _X_
Other Pressure psi Test Temp.
NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1 /2 X I I in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Forn (E00030) may be obtained from the Order Dept, ASME, 345 E. 47" St., New York, NY 10017 AGO527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Replaced both P-2 1-1 A and P-2 1-1 B contaimnent spray pumps with new pumps. Refer to ECR 03-00828.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. NIA Expiration I)ate N/A Signed 4 J 41AiA ft ISI N Owner or (Vvner's Designee, Title A1 N6 R06 Date. TANJQAt( IOA - 2005 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period 2x to #4 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
1'Z AMI---
Ins*!tor's Sigoture Commissions NB 9364 (1)(N) NJ766 National Board, State, Province, and Endorsements Date t/2X 2005 AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner ArnerGen Energy Co L.L.C. Date January 18. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet 1 of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# R2049788 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Energy Co LLC Type Code Symbol Stamp NIJ A
Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date. N/A Address
- 4. Identification of System Control Rod Drive System (225)
- 5. (a) Applicable Construction Code ASME Section I 196 Edition, NIA Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 wI 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
ASME Name of Name of Manufacturer National Year Repaired, Code Component Manufacturer Serial No. Board Other Identification Bilt Replaced, or Stamped No. Replacement (Yes or
_ _ _ _ _ _ _ _N o)
Control Rod General Electric CRD Replaced No Drive Company Assembly
- 7. Description of Work: Replace Control Rod drive (CRD) assemblies during Refuel outage.
- 8. Tests Conducted Hydrostatic_ Pneumatic_ Nominal Operating Pressure _X_
Other - Pressure psi Test Temp. I OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1)size is 8 1/2 x 11 in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47" St, New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Replaced 28 CRDs with new or overhauled units. Installed new flange bolting on all CRDs.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code,Section XI.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Sipned )LJ Jwnergm#4 or v . -JIA- ITSLr 9AOAAEN/. Date JTAMUAi't Y/ l8 2005
- Owner or Ob~er's Desgne, Titl Designeejitle - Ie CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period / to 3/4*Tand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions NB 9364 (1)(N) NJ766 Inspec Signatf National Board, State, Province, and Endorsements Date t/e/_
AG0527 (05/01)
FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As required by the Provisions of the ASME Code Section XI
- 1. Owner AmerGen Energy Co L.L.C. Date February 10. 2005 Name 200 EXELON WAY. KENNETT SQUARE. PA Sheet I of 2 Address
- 2. Plant OYSTER CREEK GENERATING STATION Unit OYSTER CREEK Name US ROUTE 9 SOUTH . FORKED RIVER, NJ 08731 WO# C2008225 Address Repair Organization P.O. No., Job No., etc.
- 3. Work Performed by AmerGen Enemy Co LLC Type Code Symbol Stamp N/A Name Authorization No. N/A 200 EXELON WAY. KENNETT SQUARE. PA Expiration Date N/A Address
- 4. Identification of System Spent Fuel Pool Cooling System (251)
- 5. (a) Applicable Construction Code ASME B31.1 1955 Edition, N/A Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1995 w/ 1996 Addenda
- 6. Identification of Components Repaired or Replaced and Replacement Components.
- 7. Description of Work: Replaced Spent Fuel Pool Cooling system pump P-I 8-1A with a new pump due to internal wear.
- 8. Tests Conducted Hydrostatic - Pneumatic Nominal Operating Pressure _X_
Other - Pressure psi Test Temp. OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 x II in. (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
(12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, NY 10017 AG0527 (05/01)
FORM NIS-2 (Back)
- 9. Remarks: Replaced Spent Fuel Pool Cooling system pump P-1 8-IA with a new pump due to internal wear and vibration.
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this replacement (repair or replacement) conforms to the rules of the ASME Code, Section Xl.
Type of Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed _ Date ,2005-Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NEW JERSEY and employed by HSB OF CT of HARTFORD. CONNECTICUT have inspected the components described in this Owner's Report during the period/AA to 14 '/O, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
< 'e~
lnspeSignatt7
-, Commissions NB 9364 (11 (N) NJ766 National Board, State, Province, and Endorsements Date 211 2005 AG0527 (05/01)