PASSPORT DOCUMENT To  : DOCUMENT CONTROL DESK Facility  : MP Department : 806 TRANSMITTAL Address  : NUC REGULATORY COMMISSION (0140)

DOCUMENT CONTROL DESK WASHINGTON, DC 20555 Page: 1 From  : NDS CONT DOCUMENTS Date/Time  : 09/20/04 10:

Trans No.  : 000064923 Transmittal Group Id: 04763 Total Items: 00002 Item Facility Type Sub Document Number/ Title Sheet Revision Doc Date Copy # Media Copies

  • 0001 MP PROC HP RPM 2.3.4 002 01 P 01 INSPECTION MAINTENANCE PROCESS FOR RESPIRATORY PROTECTION EQUIPMENT
  • 0002 MP PROC HP RPM 2.3.5 003 03 P 01 INSPECTION AND INVENTORY OF RESPIRATORY PROTECTIONEQUIPMENT I

Please check the appropriate response and return form to NDS Bldg 475/3 Millstone Power Station or Fax to 860-440-2057.

All documents received.

Documents noted above not received (identify those not received).

I no longer require distribution of these documents.

Date: Signature:

0

A. I 02t27/03 03/07/03 Approval Date Effective Date Procedure Action Request Document No.: PM 2.3.4 Writer Jean B. Olsen Rev. No. l Minor Rev.

Initiator William Robinson 002 01

Title:

Inspection and Maintenance Process for Respiratory Protection Equipment For New Documents: Document is QA Ui DH

Title:

O Revision 0 Minor Revision [ Cleanup Revision 0 Biennial Review o Cancel 3 Void (Do Not Use) 0 Expire E3 Superceded By: -

Comments: 0 Administrative Correction FLS: _AK LT 7.Y Associated ARs Reviews Print Sign Date Department

_ _ _ _ _ _ _ ~El _ _

__ _ _ _ _ _ I _ _ _ _ _ _ X _ _ _ _ _

WC 9 Att 3 Req. O Yes 0 No E _

Ucensing Basis / RCD (50.59 Screen Req. D Yes 0 No)

Tech Independent E__

Validation El None a Field -Use E Simulated Performance - Table Top and E] Comparison MP-05-DC-SAP01.004 Use MP-05-DC-SAPO1004 Walk-through' (minimum of two) Print Sign Date Dept Coordinator l NPO Member Training: El None El Nuclear Training a Briefing El Familiarization El SOR Review and Approval f SORC Review and Anoroval n Department Head Review and Approval Approval 3 Disapproval l__ NIA (1) Department Head Sign/Date (1)Department Head Approval Sign (1)SOR Sign/Date (2)SORC Meeting Number (2) Department Head Approval Sign

/ 1_(3) SORC Approval Sign If Approval Date: 0?(1/310 Effective Date: //0 MP-05-DC-FAPO1.1-005 Rev. 001 Page 1 of I

MILLSTONE NUCLEAR POWER STATION HEALTH PHYSICS SUPPORT PROCEDURE Inspection and Ma rance Process for Respiratory Prc on Equipment Approval Date: 09/13/04 Effective Date: 09/21/04 Leivel of Use I l Informationl

Millstone All Units Health Physics Support Procedure Inspection and Maintenance Process for Respiratory Protection Equipment TABLE OF CONTENTS

1. INSTRUCTIONS . ......................................... 2 1.1 Inspection and Maintenance Frequency Flowchart and Table Update .......................................... 2 1.2 Inspection and Maintenance Performance ........ ............. 3
2. REFERENCES . .......................................... 5
3. COMMITMENTS...............................................5
4.

SUMMARY

OF CHANGES ....................................... 5 ATITACHMENTS AND FORMS Attachment 1, "Inspection and Maintenance Frequency flowcharts and Thbles" ............................. 7 RPM 2.3.4 Level of Use la A Rev. 002-01 Information l K , f lof 12

1. INSTRUCTIONS By performing inspections and maintenance on respiratory protection equipment, Millstone Station will ensure operability of its respiratory protection equipment. This ensures personnel protection against airborne contaminants when using respiratory protection equipment correctly.

1.1 Inspection and Maintenance Frequency Flowchart and Table Update 1.1.1 WHEN any of the following conditions occur, Go To step 1.1.2:

  • Manufacturer instructions are revised
  • Government regulations are revised
  • Historical data dictates a review
  • New types of equipment are obtained 1.1.2 Refer To Attachment 1 and PERFORM the following:
a. REVIEW Attachment 1 for affected flowchart or table.
b. ENSURE inspection and maintenance intervals are correct as specified in the following guidelines:
  • Manufacturer instructions
  • Government regulations
  • Historical data
c. ENSURE routine inspections and maintenance are performed at regular, scheduled intervals.
d. UPDATE affected portions of Attachment 1 as required.

Level of Use olHRPIMNI Information II R WH~N'Rev.

A 23.4 002-01F Re. 020 2 of 12

1.2 Inspection and Maintenance Performance 1.2.1 DETERMINE from the following list the type of equipment to be inspected:

  • Full Facepiece or Half Mask Respirator
  • Powered Air-Purifying Respirator Units
  • Hip -Aire Breathing Apparatus
  • Scott Self-Contained Breathing Apparatus
  • Abrasive Blasting Respirator Assembly
  • Bubblehoods or TYVEK Hoods - Air Supplied or Powered Air Purifying
  • Filter Cartridges and Canisters
  • Breathing Tubes, Air Lines, Air Supply Hoses, Duo-Flow Adapters 1.2.2 IF equipment being inspected is not listed in step 1.2.1, CONTACI Health Physics Supervision.

1.2.3 IF equipment is one of the following, DETERMINE if equipment status is in-service or stored:

  • Full Facepiece or Half Mask Respirator
  • Powered Air-Purifying Units V lRPM 2.3.4 Level of Use ThN~'

Inforatio Inforatio P.-3 Rev. 002-01 of 12

1.2.4 Refer To Attachment 1 and the following list and SELECT flowchart or table that applies to equipment type and status:

  • Flowchart 1, "MSA Full Facepiece or Half Mask Respirator"
  • Flowchart 2, "MSA Powered Air-Purifying Respirator Units"
  • Flowchart 3, "MSA Hip-Aire Breathing Apparatus"
  • Flowchart 4, "Scott Self-Contained Breathing Apparatus"
  • Flowchart 5, "Bullard Abrasive Blasting Respirator Assembly"
  • Table - 1, "Bubblehoods or TYVEK Hoods - Air Supplied or Powered Air Purifying"
  • Table - 2, "Filter Cartridges and Canisters" 1.2.5 OBTAIN and REVIEW equipment history file record.

1.2.6 Based on the following, SELECT from applicable flowchart or table the activity to be performed:

  • Previous activities documented on RPM 2.3.5-001, "Equipment History Record."
  • Past equipment use
  • Future equipment use 1.2.7 ASSIGN personnel to perform required activity.

1.2.8 MONITOR activity performance and ENSURE all required activities are performed.

1.2.9 DOCUMENT activities performed on RPM 2.3.5-001, "Equipment History Record."

Level of Use }. RPM23.4 lInformation Inforation4 l m Rev. 002-01 of 12

2. REFERENCES 2.1 10CFR20, "Standards for Protection Against Radiation" 2.2 29CFR1910, "Occupational Safety and Health Standards" 2.3 NUREG 0041, "Manual of Respiratory Protection Against Airborne Radioactive Materials" 2.4 Regulatory Guide 8.15, 'Acceptable Programs for Respiratory Protection" 2.5 ANSI Z88.2-1992, 'American National Standard for Respiratory Protection" 2.6 RPM 2.3.5, "Inspection and Inventory of Respiratory Protection Equipment" 2.7 RPM 2.3.5-001, "Equipment History Record"
3. COMMITMENTS N/A
4.

SUMMARY

OF CHANGES Summary of Changes, Rev. 002-01 4.1 Added RPM 2.3.5 to References. This is corrective action to CR-04-04368.

4.2 Deleted RPM 2.3.5-002, which was cancelled.

4.3 Updated nomenclature of forms.

Summary of Changes, Rev. 002 4.4 Changes in Attachment 1:

4.4.1 Changed Flowchart Number 1 In-Service Inventory from quarterly to monthly and reformatted steps to comply with 29CFR1910.

4.4.2 Deleted time frame for Hydrostatic Test from Flowchart Number

3. This test is dependent on cylinder type and is discussed in RPM 2.35.

Level of Use

'Infrmaton' I + . M 23.

+/-Rev. 002-01

4.4.3 Deleted "(Posichek)" from "Functional Check (Posichek)" in Flowcharts Number 1, 3 and 4.

4.4.4 Changed titles of cylinders in Flowchart Number 4 to distinguish composite cylinders and fiberglass wrapped cylinders as these two types of cylinders have different inspection criteria.

4.4.5 Deleted Table -3, "Breathing Tubes, Air Lines, and Air Supply Hoses," because these items are all inspected prior to use and it is unnecessary to perform the inspection twice.

4.5 Deleted the words "Quality Assurance Program" from procedure title as this gives the wrong impression of the procedure's objective. It was replaced with the more accurate title "Inspection and Maintenance Process..."

4.6 Added Basis information that changes or revisions to this procedure must be processed through the Emergency Planning Services Department to complete a reduced effectiveness review in accordance with 10CFR50.54(q).

Level of Use AIR11.i' RPM 23.4 Rev. 002-01 Information 6 of 12

Attachment 1 Inspection and Maintenance Frequency Flowcharts and Tables (Sheet 1 of 6)

Flowchart Number 1 - MSA Full Facepiece or Half Mask Respirator I----------- -------------- ---

  • Initial Receipt Inspection
  • visual Inspection Wash
  • - Repairor7 La ckMaintenance 6

3 S On a periodic basis, respirators should be cycled between active storage and in-service.

AA RPM 2.3.4 Level of Use l-5 ~T~*N'(UNN'AC II Rev. 002-01 Information l m I \ m LI 7 of 12

Attachment 1 Inspection and Maintenance Frequency Flowcharts and Tables (Sheet 2 of 6)

Flowchart Number 2 - MSA Powered Air-Purifying Respirators Units Initial Receipt Inspection a af rom Visual

)om Inspection age To Activate Operational Check - Repair or use 9) (Field Test Unit) Maintenance Batteries/Charges Flow Che Repair or

- __ Maintenance I Install Accessories (Filters, Belt, Cover)

On a periodic basis, PAPR blowers storage and in-service.

RPM 2.3.4 Level of Use l

  • Rev. 002-01 Information l .F.Y"t% 8 of 12

Attachment 1 Inspection and Maintenance Frequency Flowcharts and Tables (Sheet 3 of 6)

Flowchart Number 3 - MSA Hip -Aire Breathing Apparatus Initial Receipt Inspection Drawn from Visual - - - -

Storeroom

  • Inspection I I a

II a

II RPM 2.3.4 Level of Use Rev. 002-01 Informationl 9 of 12

Attachment 1 Inspection and Maintenance Frequency Flowcharts and Tables (Sheet 4 of 6)

Flowchart Number 4- Scott Self-Contained Breathing Apparatus Initial Receipt Inspection Drawn from Visual

~I

  • Sf a v
  • I I

, Functional Check__Y MaiA'enance ai I -

aI RPM 2.3.4 lLevel of Usel Rev. 002-01 lInformationl 10 of 12

Attachment 1 Inspection and Maintenance Frequency Flowcharts and Tables (Sheet 5 of 6)

Flowchart Number 5 - Bullard Abrasive Blasting Respirator Assemblies r------------------------ -__

Initial Receipt Inspection room'. Inspection irage To Activate Operational Check Repair or

)use9) , 4 Maintenance RPM 23.4 Rev. 002-01 11 of 12

Attachment 1 Inspection and Maintenance Frequency Flowcharts and Tables (Sheet 6 of 6)

Table - 1

.Bubblehoods or TYVEK Hoods - Air Supplied or Powered Air Purifying Frequency Activity Prior lb Use AfterUse Visual Inspection X Discard X Table -2 Filter Cartridges and Canisters Frequency Activity Prior To Use After Use Visual Inspection X Discard X RPM 2.3.4 Level of Use A. W'pL -I Rev. 002-01 Information 12 of 12

02/27/03 02/27/03* 03107/03 Approval Date Effective Date Procedure Action Request Document No.: 1APM 2.3.5 Writer. Jean B. Olsen Rev. No. Minor Rev.

Initiator William Robinson 003 03

Title:

Inspection and Inventory of Respiratory Protection Equipment For New Documents: Document is QA El DH

Title:

O Revision Ol Minor Revision El Cleanup Revision 0 Biennial Review El Cancel El Void (Do Not Use) E3 Expire O Superceded By: -

Comments: CD Administrative Correction FLS: 4+/-i!J3107 Associated ARs 03007069, Reviews Print Sign Date Department Ol _I ___

WC 9 Att 3 Req. El Yes O No O Ucensing Basis / RCD (50.59 Screen Req. E Yes O No) __.

Tech Independent E_

Validation I None E Field - Use E Simulated Performance - Table Top and El Comparison MP405-DC-SAPO1-004 Use MP-05DC-SAPO01004 Walk-through (minimum of two) Print Sign Date Dept Coordinator NPO Member Training: O None El Nuclear Training E Briefing E Familiarization E] SOR Review and APProval n SORC Review and Approval Fl Department Head Review and Approval Approval 3 Disapproval l N/A (1) Department Head Sign/Date (1) Department Head Approval Sign (1) SOR .Sign/Date (2) SORC Meeting Number (2) Department Head Approval Sign o t (3) SORC Approval Sign ___

AprvlDate:&l/ L7q Effective Date: MO0a10 MP-05-DC-FAPOI .1-005 Rev. 001 Page 1 of

9 MILLSTONE NUCLEAR POWER STATION HEALTH PHYSICS SUPPORT PROCEDURE Inspection and In ory of Respiratory Protectic uipment Approval Date: b4 1,/'1/I I /

Effective Date: 09/ 1~11 C lLevel of Use l l Informationl

4

-Millstone All Units Health Physics Support Procedure Inspection and Inventory of Respiratory Protection Equipment TABLE OF CONTENTS

1. PURPOSE .......................................... 2
2. PREREQUISITES .......................................... 4
3. PRECAUTIONS ........................................ 5 5........
4. INSTRUCTIONS . .......................................... 6 4.1 Equipment History ......................................... 6 4.2 Tight-Fitting Respirator Inspection ............ ............... 8 4.3 Tight-Fitting Respirator Leak Check ........ ................. 11 4.4 MSAPowered Air Purifying Respirators Inspection ..... ....... 13 4.5 Bullard Abrasive Blasting Respirator Assembly Inspection .15 4.6 Regulators and Flow Control Valve Inspection .17 4.7 Supplied Air Line or Hose Inspection .18 4.8 Filter Cartridges and Canisters Receipt Inspection .18 4.9 Hood Inspection .19 4.10 Disposable Dust Mask Inspection .20 4.11 Documentation .20
5. REVIEW AND SIGNOFF . .21
6. REFERENCES .. 21
7.

SUMMARY

OF CHANGES . .21 ATTACHMENTS AND FORMS RPM 2.3.5-001, "Equipment History Record" Level of Use l 4 5 o Rev.003-03

[1 of23

1. PURPOSE 1.1 Objective Provide instructions for inspection of the following types of respiratory protection equipment:
  • Full Facepiece
  • Half Mask
  • MSA Powered Air Purifying
  • Bullard Abrasive Blasting Assembly
  • Regulators
  • Flow Control Valves
  • Filter Cartridges and Canisters
  • Supplied Air Lines
  • Disposable Dust Mask For that equipment on a routine inspection frequency, the record of inspection on the equipment history file will provide proof of inventory.

1.2 Discussion A well maintained inspection program for respiratory protection equipment at Millstone Station ensures initial and continued operability of this equipment and ensures personnel protection against airborne contaminates when using this equipment.

RPM 2.3.5-001 may be computer generated provided all information required by the procedure is on the form.

1.3 Applicability This procedure cannot be used for other respiratory protection equipment not maintained by Health Physics but approved for use by Site Safety and Health and Health Physics in accordance with MP-19-RSP-PRG01, "Respiratory Protection Program Description."

Us .

'TIN

+

6 ac*T'CRVW + RPM 2.3.5 Rev. 003-03 iation ' o2

Breathing air supplies and associated equipment provided by vendors explicitly for use in diving operations is not considered respiratory protection equipment and therefore not covered by this procedure.

1.4 Frequency 1.4.1 An inspection of respiratory protection equipment shall be performed as follows:

  • upon initial receipt for reusable items
  • either upon initial receipt or prior to intended use for consumable items
  • Monthly for in-service and active stored respiratory protection equipment.
  • Annually or prior to placing in-service for stored respiratory protection equipment.
  • Routinely before and after each use.

RPM 23.5 Level of Use jp N'A;V$*~

Rev. 003-03 3 of 23

2. PREREOUISITES 2.1 General N/A 2.2 Documents 2.2.1 MP-17-RM-SAP01, "Turnover and Retrieval of Nuclear Plant 1I Records" 1G 2.2.2 RPM 2.3.7, "Cleaning and Sanitation of Respiratory Protection Equipment" 2.2.3 RPM 2.3.8, "PAPR Unit Field Testing and Battery Charging" 2.3 Tools and Consumables 2.3.1 Foam filters 2.3.2 Brass wire cloth 2.3.3 Plastic outer lenses 2.3.4 Respirator bags 2.3.5 Respirator filters 2.3.6 Disposable dust masks 2.4 Definitions 2.4.1 ABRA - Abrasive Blasting Respirator Assembly 2.4.2 Active Stored Respiratory Protection Equipment - Equipment that has been initial receipt inspected and tested and is readily available to be placed in-service. This equipment may have been previously been in-service but has been stored active to reduce amount of in-service equipment.

2.43 BREATHE - To draw air into and expel from the lungs.

2.4.4 EXHALE - To breathe out.

2.45 INHALE - To breathe in.

RPM 2.3.5 Level of Use Rev. 003-03 Information l 4 of 23

2.4.6 Initial Receipt - When respiratory protection equipment is received by Health Physics personnel either directly from the vendor or in case of direct stock items from the warehouse.

2.4.7 In-service Respiratory Protection Equipment - Equipment that has been initial receipt inspected and tested and is readily available for immediate use.

2.4.8 Monthly - every 31 days, +/- 25% (7days) 2.4.9 Non-repairable Defect - A defect that renders the entire device unusable.

2.4.10 Repairable Defect - A defect in a component that can be easily repaired or replaced thus making device usable.

2.4.11 Stored New Respiratory Protection Equipment - New equipment, that has not been initial receipt inspected or tested and is not readily available to be placed in-service.

2.4.12 SANITIZE - To make sanitary by cleaning or sterilizing.

3. PRECAUTIONS N/A lLevel ofUse l 4-A 4T1 I

1_11RPM 2.3.5 RFWTMInr YWI Rev. 003-03 Information! l 5 of 23

4. INSTRUCTIONS Respirator 4.1 Equipment History

[Technician J NOTE Consumable items such as dust masks, hoods, filter cartridges or canisters and respirator parts do not require equipment history records. These items are inspected once either upon initial receipt or prior to intended use and are discarded after use or if found defective.

4.1.1 IF preparing a new equipment history record, PERFORM the following:

a. IE equipment meets any of the following criteria, ASSIGN each device a unique serial number and Go To step 4.1.2.
  • Tightfitting respirators
  • Supplied-air respirator kits
  • Abrasive blasting respirator assemblies 4.1.2 OBTAIN RPM 2.3.5-001, "Equipment History Record."

I:

v..s .V*Ak~y~ RPM 2.3.5 Level of Use l m Information l R@:t~r

-~

Si. Rev. 003-03 6 of 23

4.1.3 For each device, DOCUMENT the following on RPM 2.3.5-001.

Equipment Code, e.g.,

  • B = Bullard, helmet
  • C = MSA, Comfo II, half mask, radiologically clean
  • D = North, half mask, radiologically clean
  • E = Emergency MSA, full face negative pressure, radiologically clean
  • K = MSA, full face negative pressure, radiologically clean
  • M = MSA, full face negative pressure
  • P = Bullard, pump
  • X = MSA, Comfo II, half mask
  • Serial number assigned
  • Today's date
  • Action performed on device, e.g., inspection, decon, storage 4.1.4 WHEN equipment history record has been prepared, EXIT this section of the procedure.

RPM 2.3.5 e.030 Level of Use ~~C EI~

Information 7o2

NOTE Sections 4.2, 4.4, and 45 are for both receipt and routine inspections.

4.2 Tight-Fitting Respirator Inspection 4.2.1 VERIFY respirator has a serial number.

4.2.2 IE respirator does not have a serial number, Refer To step 4.1.1 and ASSIGN a serial number.

4.2.3 Refer To Table - 1 and visually INSPECT respirator rubber components for the following:

a. Mold
b. Defects such as cracking and tears
c. Structural integrity
d. Pliability Table - I Respirator Rubber Mold Components

_Facepiece Filter Gaskets Straps Hose Gaskets Inhalation Valve(s) Nosecup (If supplied)

Exhalation Valve(s) (negative pressure or continuous flow only) 4.2.4 IF any defects are found AND respirator is repairable, REPAIR respirator.

4.2.5 .IE any defects are found AND respirator is not repairable, PERFORM the following:

a. CONTACT Health Physics supervision for instructions on equipment disposition.
b. IF any respirators remain to be inspected, Go To step 4.2.1.
c. iEall respirators have been inspected, Go To step 4.2.14.

k2-Level V of Leve of

~RPM se 2.3.5 Rev. 003-03 normaon 8f23

4.2.6 Visually INSPECT the following for defects:

  • Strap buckles
  • Clamps
  • IE a negative pressure or continuous flow respirator, exhalation valve cover
  • IF a pressure demand respirator, pressure demand exhalation valve
  • IE a continuous flow or pressure demand respirator, hose connections
  • Full facepiece respirator, facepiece lens
  • Full facepiece respirator, lens retainer ring(s)
  • Half mask respirator, head harness cradle
  • Negative pressure respirator, speaker diaphragm housing or cartridge receptacle(s) 4.2.7 IE any defects are found AND respirator is repairable, REPAIR respirator.

4.2.8 IE any defects are found AND respirator is not repairable, PERFORM the following:

a. CONTACT Health Physics supervision for instructions on equipment disposition.
b. IF any respirators remain to be inspected, Go To step 4.2.1.
c. IE all respirators have been inspected, Go To step 4.2.14.

4.2.9 IF inspection performed was receipt inspection, PERFORM the following:

a. Refer To RPM 2.3.7, "Cleaning and Sanitation of Respiratory Protection Equipment" and WASH respirators.
b. Refer To Section 4.3 and PERFORM a leak check.

j Ai RPM 2.3 .5 Level of Us, Informatior HI.NK'

~ Rev. 003-03

4.2.10 Visually INSPECT respirator gaskets.

4.2.11 EF any defects are found, REPLACE gaskets.

4.2.12 IF respirator is not part of a kit, PERFORM the following:

a. PLACE respirator in a respirator bag.
b. PLACE respirator in-service QB active storage.

4.2.13 IF respirator is part of a kit, PLACE respirator in kit.

4.2.14 DOCUMENT actions taken on RPM 2.3.5-001.

AA RPM 2.3.5 Level of Use L Information ~A. I'3/4 Rev. 003-03 10 of 23

4.3 Tight-Fitting Respirator Leak Check NOTE Strapping the respirator on is not necessary as long as respirator can be held snugly against the face while performing leak check.

4.3.1 PERFORM manual positive pressure leak checks as follows:

a. PLACE facepiece snugly against face QB don respirator and EXHALE.
b. INHALE and CLOSE off exhalation valve with palm of hand.
c. EXHALE gently so a slight positive pressure is felt inside respirator.
d. IE respirator remains pressurized AND no outward leakage of air is detected, Go To step 4.3.2.
e. IE leak check was not satisfactory, Go To step 43.4.

4.3.2 PERFORM manual negative pressure leak check as follows:

NOTE Strapping the respirator on is not necessary as long as respirator can be held snugly against the face while performing the leak check

a. PLACE facepiece snugly against face OR don respirator.
b. -EXHALE and CLOSE off filter housing or hose connection.
c. INHALE so respirator collapses slightly against face.
d. HOLD breath for at least 10 seconds.
e. IE respirator remains collapsed and no inward leakage of air is detected, Go To step 4.3.3.
f. IEleak check was not satisfactory, Go To step 4.3.4.

Le v e o f s e Ž'AtIBT ~R P M.

. 20 3 .5 3 Information Re.033

4.3.3 Refer To RPM 2.3.7, "Cleaning and Sanitation of Respiratory Protection Equipment" and SANITIZE respirators.

4.3.4 DOCUMENT actions taken on RPM 2.3.5-001.

III RPM 2.3.5 Level of Use l M-Rev. 003-03 Information 12 of 23

4.4 MSA Powered Air Purifying Respirators Inspection 4.4.1 IF tight-fitting respirator is included as part of PAPR assembly ANDI it has not been inspected, Refer To Section 4.2 and INSPECT respirator.

4.4.2 Visually INSPECT the following for damage or defects:

a. Respirator blower unit
b. Breathing hose la:
c. Filter gaskets
d. Respirator belt
e. IF filters are included as part of assembly, INSPECT filters for casing damage.

4.4.3 IF any defects are found AND PAPR is repairable, REPAIR PAPR.

4.4.4 IF any defects are found AND PAPR is not repairable, PERFORM the following:

a. CONTACT Health Physics supervision for instructions on equipment disposition.
b. Ef any PAPRs remain to be inspected, Go To step 4.4.1.
c. LE all PAPRs have been inspected, Go To step 4.4.7.

4.4.5 Refer To RPM 2.3.8, "PAPR Unit Field Testing and Battery Charging" and TEST the following:

a. Battery module
b. Battery charger
c. Blower 4.4.6 ASSEMBLE PAPR as follows:
a. INSTALL charged battery module to blower assembly.
b. CONNECT breathing tube to blower assembly.

A l IA Level of Use Information II ~TO?~ ~THN~

A

'~ACT Blc Rl~A~W RM 23.

Rev. 003-0 3 f2

c. INSTALL PAPR protective cover.
d. INSTALL filters;
e. INSTALL belt.

4.4.7 DOCUMENT actions taken on RPM 2.3.5-001.

As A RPM 2.3.5 Level of Use l FEt- Rev. 003-03 Information -l.TH 14 of 23

4.5 Bullard Abrasive Blasting Respirator Assembly Inspection 4.5.1 DISCONNECT air control system hose from respirator helmet.

4.5.2 OPEN window frame and REMOVE plastic outer lens from clamps.

4.5.3 IF installed, REMOVE clear mylar lens covers.

4.5.4 Visually INSPECT plastic outer lens for damage, defects and visibility.

4.5.5 REMOVE the following from helmet:

  • Cape
  • Foam head pad, if installed
  • Headband suspension
  • Chin strap (optional)
  • Plastic inner lens
  • Window frame gasket 4.5.6 Visually INSPECT items removed from helmet for damage or defects.

4.5.7 IF defects are found in any of the items removed from helmet, REPLACE defective component.

4.5.8 Visually INSPECT the helmet for damage and defects.

4.5.9 In defects are found in any helmet component, REPLACE defective item.

4.5.10 Visually INSPECT the air control system components for damage and defects.

of Use l iRPM 2.3.5 L~atij / ~Rev.

/ '~

003-03 15 of 23

4.5.11 IE defects are found in any of air control system components, PERFORM one of the following:

  • REPLACE defective component e REPAIR defective component
  • REPLACE entire air control system 4.5.12 IE respirator assembly is used (not a receipt inspection), CLEAN assembly in accordance with manufacturer's instructions.

4.5.13 REPLACE the following on helmet:

  • Cape
  • Foam head pad, if installed
  • Headband suspension
  • Chin strap (optional)
  • Plastic inner lens
  • Window frame gasket 10 4.5.14 PLACE respirator assembly in-service or active storage.

4.5.15 DOCUMENT actions taken on RPM 2.3.5-001.

l Level of Use l- 4 - RPM 2.3.5 Information I I ~

'~T

~16

N( e.030 of 23

4.6 Regulators and Flow Control Valve Inspection 4.6.1 Visually INSPECT regulator for external damage and defects.

4.6.2 Visually INSPECT flow control valve for external damage and defects.

4.6.3 IF any regulator or flow control valve defects are found, CONTACT Health Physics supervision for instructions on equipment disposition.

4.6.4 PERFORM operability check of regulators.

a. ATTACH regulator to a respirator and an air supply of proper pressure.
b. TURN on air supply.
c. PLACE respirator against face.
d. CHECK regulator operation by breathing normally.
e. REMOVE respirator from face.
f. TURN off air supply.
g. DETACH regulator from respirator and air supply.

4.6.5 PERFORM operability check of flow control valves as follows:

a. ATTACH flow control valve to an air supply of proper pressure.
b. TURN on air supply.
c. CHECK flow of air at valve outlet.
d. IF valve is an adjustable flow control valve, TURN valve knob from start to stop and VERIFY air flow increase and decrease.
e. TURN off air supply.
f. DETACH flow control valve from air supply.

4.6.6 IF regulator or flow control valve does not perform as expected during operability check, CONTACT Health Physics supervision for instructions on equipment disposition.

4.6.7 PLACE regulators or flow control valves that pass inspection in-service or active storage.

Level of Use l A,.RPM 2.3.0 Information ,~cT /k .I17 e.030 of 23

4.7 Supplied Air Line or.Hose Inspection 4.7.1 Visually INSPECT the following supplied air line or hose components for damage and defects.

a. Hose
b. Hose quick-connect
c. Hose threaded fitting 4.7.2 IF any defects are found AND component is repairable, REPAIR component.

4.7.3 EF any defects are found AND component is not repairable, CONTACT Health Physics supervision for instructions on equipment disposition.

4.7.4 PLACE supplied air lines or hoses that pass inspection in-service or active storage.

4.8 Filter Cartridges and Canisters Receipt Inspection 4.8.1 Visually INSPECT for the following:

a. Filter cartridges and canisters for damage to casings.
b. Filter label corresponds to filter ordered.
c. JE filter normally has a paper seal, seal is present and not damaged.
d. IF item has an expiration date, expiration date is greater than one year from receipt inspection.

4.8.2 IF any defects are found, PERFORM the following:

a. CONTACT Health Physics supervision for instructions on equipment disposition.
b. IE any items remain to be inspected, Go To step 4.8.1.
c. IE all items have been inspected, EXIT this procedure.

4.8.3 IE filters will be placed in storage, STORE filters so filters with nearest expiration dates will be used first.

Level of Use l. A RPM2.3.5 HINKZ

'TTO~ iC] RV Rev. 003-03 Information \ I' 4 1of2

4.9 Hood Inspection 4.9.1 Visually INSPECT hood for the following:

  • Installation of air fittings
  • Tears and holes
  • Integrity of heat sealed seams
  • Uneven sewing of sewn seams
  • Scratches in the lens 4.9.2 IF hood is plastic (i.e. bubblehood), visually INSPECT for the following:
  • Nicks
  • Cracks
  • Structural imperfections 4.9.3 IF any defects are found, PERFORM the following:
a. CONTACT Health Physics supervision for instructions on hood disposition.
b. IF any hoods remain to be inspected, Go To step 4.9.1.
c. IF all hoods have been inspected, EXIT this procedure.

4.9.4 IF PAPR Tyvek hood has an exhalation valve, CHECK exhalation valve and cover are present.

4.9.5 IF PAPR 'Ivek hood does not have an exhalation valve, INSTALL exhalation valve.

4.9.6 IF hood is a plastic bubblehood, CHECK muffler is attached.

4.9.7 I-Fhood is a plasticbubblehood AN-Da muffler is not attached, RETURN hood to manufacturer.

4.9.8 IF hood is a 'lyvek hood, CHECK adjustable headband is attached.

4.9.9 IF hood is a 'Iyvek hood AND adjustable headband is not attached, ATTACH an adjustable headband.

Level of Use l A ReM 2.3-5 IInformationI> A A 19 of03 Rv 19 23

4.10 Disposable Dust Mask Inspection 4.10.1 Visually INSPECT dust mask for the following defects:

  • Holes
  • Tears
  • Broken or missing straps
  • Broken or missing nosepiece metal strip
  • Broken or missing exhalation valve assembly 4.10.2 JE any defects or abnormalities are observed in any single dust mask, DISPOSE of dust mask.

4.10.3 IE any defects or abnormalities are observed in several or all dust masks in a lot, RETURN dust masks to warehouse for return to manufacturer and OBTAIN a new lot of dust masks for inspection.

4.11 Documentation 4.11.1 FILE or STORE RPM 2.3.5-001.

4.11.2 On a yearly basis, Refer To MP-17-RM-SAPO1, "Turnover and I(

Retrieval of Nuclear Plant Records," and SEND RPM 2.3.5-001 I(C to NDS.

RPM 2.3.5 level of Use xr.."mIlkAd I'01 Rev. 003-03 lInformation J P 20 of 23

5. REVIEW AND SIGNOFF 5.1 N/A
6. REFERENCES 6.1 10CFR20, "Standards for Protection Against Radiation" 6.2 29CFR1910.134, "Respiratory Protection" 6.3 NUREG 0041, "Manual of Respiratory Protection Against Airborne Radioactive Materials" 6.4 Regulatory Guide 8.15, 'Acceptable Programs for Respiratory Protection" 6.5 ANSI Z88.2-1992, 'American National Standard for Respiratory Protection" 6.6 NOV VIO 50-245,336,423/97-81-02 and CR M3-97-4483 6.7 Memo EP-98-127, "Implementation of Millstone Emergency Plan Revision #24," from Mark White to Millstone HP Management Personnel l 6.8 RPM 2.3.4, "Inspection and Maintenance Process for Respiratory C3 Protection Equipment" I
7.

SUMMARY

OF CHANGES Summary of Changes, Rev. 003-03 7.1 Added RPM 2.3.4 to References. This is corrective action to CR-04-04368.

7.2 Updated procedure title of NDM I to MP-17-RM-SAP01.

Summary of Changes, Rev. 003-02 7.3 Electronically added minor revision 003-01.

7.4 Corrected spelling of Shift Manager in step 7.2 Level of Use l RPM 2.035 Information ~ fik

~ Rv.030 21tof 23

7.5 The following items were deleted. This subject matter is owned by Site Fire Protection and has been incorporated into SFP 24, "Inspection and Inventory of Self Contained Breathing Apparatus."

  • MP-ENGPROG-99-0073, "Proposed change to RPM 2.3.5 for Fire Fighting SCBA equipment," from Jerry Derryberry to Ira Haas, dated 2/19/99 was also deleted.
  • Basis information that changes or revisions to this procedure must be processed through the Emergency Planning Services Department to complete a decrease in effectiveness review in accordance with 10CFR50.54(q). (This was deleted with the concurrence of Mark White, Emergency Planning, December 13, 2001.)
  • Missing Respiratory Protection Equipment
  • RPM Form 2.3.5-3, "SCBA and Air Cylinder Inspections,"
  • "SCBA Routine Inspection."
  • MSA Hip-Aire Respirators Kit Inspection
  • Attachment 1, "Combined Millstone Fire Protection Required SCBAs,"
  • "Air Cylinder Inspection"
  • SCBA Kit Receipt Inspection
  • CGA C-4-1978, "Method of Marking Portable Compressed Gas Containers to Identify the Material Contained"
  • CGA C-6.1 -1984, "Standards for Visual Inspection of High Pressure Aluminum Compressed Gas Cylinders"
  • CGA C-6.2-1988, "Guidelines for Visual Inspection and Requalification of Fiber High Pressure Cylinders"
  • Unit 1 Technical Requirements Manual OPS Form 273-7.4, "Control Room Habitability Technical Requirements" 7.6 RPM 2.3.10, "Operation of PosiChek 2," no longer exists and was deleted.

7.7 Corrected title of Safety Department.

Use X - f A RPM2.3.5 iationp I Re.033 22 of 23

1 7.8 Changed "breathing tube" to "breathing hose."

7.9 Deleted steps for Bullard ABRA Model 77/46 as it has been replaced by Model 88.

7.10 Deleted excessive detail on how to store ABRA; the respirator assembly just needs to be ready for issue.

7.11 Deleted "broken or missing buckles" from disposable dust mask as this type is not used at Millstone.

Summary of Changes, Rev. 003 7.12 Added Basis information that changes or revisions to this procedure must be processed through the Emergency Planning Services Department to complete a decrease in effectiveness review in accordance with I I0CFR50.54(q).

7.13 Added new Attachment 1, "Combined Millstone Fire Protection Required SCBAs" and steps in Sections 4.7 and 4.8 to verify Fire Protection respiratory protection equipment is present and operable. If inventory is missing or inoperable the Shift Manager is notified and the equipment replaced. This addresses A/R 99000357-02.

7.14 Deleted authorized acronyms.

lLevelof Use t 4Alw" RPM 2.3.5 Rev. 003-03 l Informationl 23 of 23