SURRY EXAM
50-280, 50-281 LXXM-301
FEBRUARY 24 - MARCH 2
& MARCH 4,2004 (WRITTEN)
US. Nuclear Regulatory Commission
Site-Specific
DRAFT Fa0 Written Examination
Instructions
Use the answer sheets provided to document your answers. Staple this COQW skeet on
top of the answer sheets. To pass the examination you must achieve a final grade of at
least 80.00 percent. Examination papers will be collected six hours after the examination
starts.
I
Applicant Certification
All work done on this examination is my own. I have neither given nor received aid.
I
Aaolicant's Sianature
1 Examination Value:
Points
I Applicant's Score:
Points
I Applicant's Grade:
Percent
Surry Nuclear Plant 2004-301
DRAFT 80 lnital Exam
1 . 003~4.03
-_
O O ~ / ~ / ~ / R C P
LIrBR%CmICbN/mM
__
___
~ . ~ / ~ . s ~ / s K o ~ ~ ~ ~ / R / M A H / s D R
~~
1 -
Which ONE of the following correctly describes the Reactor Coolant Pump (RCP)
bearing oil lift system?
A! The oil lift pump discharge pressure must be greater than 350 psig prior ts RCI
start. Once the RCP reaches operating speed the thrust runner circulates oil ir
upper and lower bearing assemblies.
B. The oil lift pump discharge pressure must be greater than 380 psig prior to RCI
start. Once the RCP reaches operating speed the RCP Qil Lift System supplie
bearing lubrication.
C. The oil lift pump discharge pressure must be greater than 350 psig prior to RCI
start. Once the RCP reaches operating speed the RCP Oil Lift System supplie
bearing lubrication.
B. The oil lift pump discharge pressure must be greater than 300 psig prior to RCI
start. Once the RCP reaches operating speed the thrust runner circulates oil ir
upper and lower bearing assemblies.
References:
ND-88.1 -t&-6, Reactor Coolant Pumps, Rev. 16
Distractor Analysis:
A. Correct because there is a 350 psig discharge interlock with respective WCP. The
Oil Lift Pump ensures adequate lubrication upon RCP start, but once the pump
reaches operating speed, the thrust runner acts as an oil pump and circulates oil in
the upper and lower bearing assemblies.
5. Incorrect because pressure interlock is at 350 psig, not 300 psig.
C. lncorrect because thrust runner circulates oil in upper and lower reservoir, not the
El. Incorrect because pressure interlock is at 350 psig, not 300 psig.
Oil Lift System.
803 Reactor Coolant Pumps
K4.03: Knowledge of RCPs design feature(.$) and / or interlock(s) which provide for the
following: Adequate lubrication of the RCP.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
2. 004A32.17
~_
00112/1/C'VCS/C/A 3 413 7/NlSKO4301/R/MABZB/SDR
~
-~
__
The following Unit 1 conditions exist:
- Operating at 85% power
- A Pressurizer Safety Valve is leaking
~
fC-B8, PWZR LO PRESS, annunciates
- 1 -AP-31 .OO, Increasing or Decreasing RCS Pressure, has been entered
Pressurizer pressure control is in its normal configuration
Which ONE of the following correctly describes the affect on charging flow an^ an
appropriate mitigating action in accordance with 1 -AP-31 .00?
A. Charging flow initially increases. Place the PRZR PRESS MASTER CNBRb in
MANUAL and increase the demand to try to stop the pressure decrease.
8. Charging flow initially decreases. Place the PWZW PRESS MASTER CNTRL in
MANUAL and increase the demand to try to stop the pressure decrease.
CY Charging Blow initially increases. Place the PRZR PRESS MASTER CNTWL in
MANUAL and decrease the demand to try to stop the pressure decrease.
D. Charging flow initially decreases. Place the PRZR PRESS MASTER CNTRL in
MANUAL and decrease the demand to try to stop the pressure decrease.
References:
ND-93.3-LP-5, Pressurizer Pressure Control, Rev. 9
ND-88.3-LP-2, Charging and Letdown, Rev. 10
1 -AP-31.08, Increasing or Decreasing WCS Pressure, Rev. 4
Distractor Analysis:
A. Incorrect because increasing the demand will lower pressure, not increase it.
Ea. Incorrect because charging flow will not initially decrease and increasing the
C. Correct because charging flow will initially increase due to the sudden pressure drop
demand will lower pressure, not increase it.
in the RCS. Also, decreasing the demand on the controller while in manual will act
to try to raise pressure.
D. Incorrect because charging flow will not initially decrease.
004 Chemical and Volume Control
A2.17: Ability to (a) predict the impacts of the following malfunctions or operations on
the GVCS; and (b) based on those predictions use procedures to correct, control, or
mitigate the consequences of those malfunctions or operations: Low PZR pressure.
Surry Nuclear Plant 2004-301
DRAFT 80 lnital Exam
~
- 1
3. 005K5.02 00 1 /2/ 1RIIFUMEM 3 4/3.5/B/§R0430
I/WMAB/SDK
-
__ __
The following Unit 1 conditions exist:
~
RCS level is 12.5 feet on 1-RC-LI-IOOA
- RCS level is 12 feet 5 inches on 1-WC-LR-105
.. A loss of decay heat removal has occurred and 1-AP-27.00, Loss of Decay Heat
Removal Capability, has been entered.
- The RHR system has just been made available.
Which ONE of the following methods per 1-AP-27.00 should be used to sweep air from
the RHR lines during a loss of decay heat removal capability if inadequate time exists
to completely vent the RHR System prior to boiling in the core?
A:' Refill the RCS to 13.5 Beet, verify 10 O F subcooling, and run an RHR pump at a flow
rate of > 2950 gpm.
B. Maintain WCS level at 12.5 feet, verify subcooling, and run an RHR pump at a flow
C. Maintain RCS level at 12.5 feet, verify subcooling, and run an RHR pump at a flow
of > 2950 gpm.
of < 2950 gpm.
%a. Close WH-MOV-172QA and B, WHR Outlets, then open "A" and "C" Safety Injection
Accumulator isolation MQVs.
Surry
References:
NB-88.2-LP-1, Residual Heat Removal System Description, Rev. 8
ND-88.2-LP-2, Operation of Residual Heat Removal System, Rev. 15
ND-88.2-LP-3, Draindown and Midloop Operations, Rev. 12
1 -AP-27.00, Loss of Decay Heat Removal Capability, Rev. 10
Distractor Analysis:
A. Correct because based on procedural Note in 1 -AP-27.00, Page 16 or 19, Rev. 10.
B. Incorrect because RCS needs to be filled to 13.5 feet.
C. Incorrect because RCS needs to be filled to 13.5 feet. Also flow needs to be
greater than 2950 gpm.
D. Incorrect because no procedural guidance exists to support the actions.
Surry ILT Exam Bank Question #275
K5.02: Knowledge of the operational implications of the following concepts as they
apply to the RHRS: Need for adequate subcooling.
Sur9 Nuclear Plant 2004-301
DRAFT WO lnital Exam
Unit 1 tripped 30 minutes ago. The following plant conditions currently exist:
~ 7 CETCs indicate between 708 O F and 750 'F and slowly rising
- No RCPs are operating
- Steam Generator levels are 20% and rising
- Subcooling based OR CETCs is 0 O F
~
E-0, Reactor Trip or Safety Injection, has been exited and Safety Function Staters
~
RCP Seal Injection flow is 3 gpm to all WCPs
- WCP Seal delta-Ps are all approximately 200 psid
- Attempts to establish HHSB flow have failed
RVklS Full Range is indicating 46% and slowly lowering
Trees are being monitored
Source Range Startup Rate is zero
Which ONE of the following describes the correct strategy for mitigating the
consequences of these conditions?
A. Depressurize all intact steam generators at maximum sate, but maintain steam flow
less than 1 .0 x 1 O5 PPW to try establish accumulator and RHR flow. If CETCs rise
above 1200 O F , then check conditions for starting a RCP.
B. Depressurize all intact steam generators at maximum rate, but maintain steam flow
less than 1 .O x lo5 PPH to try to establish accumulator and RHR flow. Even if
CETC temperatures rise above 1200 O F , RCPs should not be started due to low
WCP seal injection flow.
C. Depressurize all intact steam generators at maximum rate, but maintain steam flow
less than I .O x 1 O6 PPH to try to establish accumulator and RHR flow. Even if
CETC temperatures rise above 1208 O F , RCPs should not be started due to low
RCP sea1 injection flow.
D:' Depressurize all intact steam generators at maximum rate, but maintain steam flow
less than 1 .O x IO6 PPH to try to establish accumulator and RHR flow. If CETCs
rise above 1200 O F , then check ccanditisns for starting a RCP.
Surry Nuclear Plant 2004-381
DRAFT WO lnital Exam
Surry
References:
ND-95.3-LP-38, FR-C. 1 Response to Inadequate Core Cooling, Rev. 8
FR-C. 1, Response to Inadequate Core Cooling, Rev. 18
Distractor Analysis:
A. Incorrect because 1 .Q x lo5 PPH is well below the MSlV closure setpoint and does
not even approach the maximum rate (an entire order of magnitude low).
3. Incorrect because 1.8 x lo5 PPH is well below the MSlV closure setpoint and does
not even approach the maximum rate (an entire order of magnitude low).
C. Incorrect because RCPs should be started even when normal conditions not met.
D. Correct because procedural guidance exists to support the actions. MSlV closure
will occur if flow is greater than 1 .0 x IO6 PPH. The purpose for the actions is to
establish low head flow from accumulators and LHSB. WCP support criteria is
desirable, but not a prerequisite for starting RCPs.
006 Emergency Core Cooling
K.6.03: Knowledge of the effect of a loss or malfunction on the following will have on
ECCS: Safety injection Pumps.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
The following conditions exist:
- Unit 1 is at 90% power
- Reactor protection testing is in progress
- Reactor Trip Breaker "A'& is closed
~
Reactor Trip Breaker "B" is open
- Reactor Trip Bypass Breaker 'W' is racked in and closed
Which ONE of the following describes the plant response if reactor trip bypass breaker
"A" is racked in and closed?
A. Both reactor trip bypass breakers "A" and "B'& and reactor trip breaker "A" will trip
open and the reactor wiSi trip.
B:' Only reactor trip bypass breakers "A" and "5" will trip open and the reactor will trip.
6. Reactor trip breaker "A" will trip open and the plant will remain at 90% power.
D. Reactor trip bypass breaker "A" will trip open and the plant will remain at 98%
power.
References:
ND-93.3-LP-10, Reactor Protection - General, Rev. 5
Distractor Anaysis:
A. Encorrect because reactor trip breaker "A" will not open.
B. Correct because this is the correct response per NB-93.3-LP-10.
C. Incorrect because reactor trip breaker "A" will not open and plant will trip.
D. Incorrect because the plant will trip.
Sur9 IhT Bank Question #I 667
007 Reactor Trip Stabilization
EK2.02: Knowledge of the interrelationships between a reactor trip and the following:
B reake rs
~ re lays, and disconnects.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
6. 007K5.02 001/',/11PRT PZR RUBBLEKI.4 3.1/3.4/B/SR04301~AR/SDR
-~
~
~
-
1
Given the following Unit 1 conditions:
- A heatup is in progress to return to power from a cold shutdown condition
- RCS is Filled and vented
- Pressurizer is solid
- A nitrogen blanket has been established on the PWT
- PRT bevel = 95%
- Pressurizer Heaters are energized
Which ONE of the following must be accomplished prior to drawing a bubble in the
Pressurizer?
r
A! Drain the PRT to 60 - 80%.
3. Verify VCP oxygen concentration less than 3%.
C. Drain the Pressurizer to 22.2%.
,
D. Pressurize the RCS to 200 - 2763 psig on PI-i -403,
Nar Range.
Surly
References:
1 -GOP-I .I I Unit Startup, RCS Heatup from Ambient to 195 Degrees F,, Rev. 25
1 -O$-RC-011, Pressurizer Relief Tank Operations, Rev. 13
Distractsr Analysis:
A. Correct because GO$-1 .? Step 5.5.4 directs establishment of normal PRT level
prior to drawing a bubble. OP-RC-011 Step 5.1.1 states the normal PRT level to be
60 - 80%.
B. Incorrect because GOP-1.1 Step 5.5.6 requirement is to verify VCT oxygen < 2%.
C. Incorrect because this is an action following establishment of drawing a bubble
B. Incorrect because RCS should be between 300 and 378 psig on PI-1-403.
(GOP-I .I, Step 5.5.13).
009 Pressurizer Relief / QuenchTank
K5.82: Knowledge of the operational implications of the following concepts as they
apply to PWTS: Method of forming a steam bubble in the PZR.
Sur9 Nuclear Plant 2004-301
DRAFT RO lnital Exam
7.
~
008AA2.06 001/ I/ 1iPRESSURE TRANSMITTEWC'IA 3.3/3.6NSR0430 IITPIMABISDK
.~
Given the following Unit 1 conditions:
~
Reactor power = 100%
- All other parameters are at normal steady state values
- Subsequently PT-444 fails high
I
Assuming no operator action is taken, which ONE of the following is correct?
A. PORV-i455C opens, pressure decreases to 2000 psig, PORV-1455C closes, and
pressure stabilizes around 2800 psig.
3. PORV-I456 opens, pressure decreases to 2000 psig, PORV-1456 closes, and
C:' PORV-14556 opens, at 2000 psig PORV-14556 closes; however, pressure will
pressure stabilizes around 2000 psig.
continue to decrease causing a reactor trip and safety injection.
D. POWV-I456 opens, at 2000 psig PORV-1456 closes; however, pressure will
continue to decrease causing a reactor trip and safety injection.
Sur9
References:
NB-93.3-LP-5, Pressurizer Pressure Control, Rev. 9
Distractor Analysis:
A. Incorrect because both spray valves also open, which causes pressure to continue
to decrease.
5. Incorrect because both spray valves open, which causes pressure to continue to
decrease. Also incorrect because POW-1 456 does not open.
C. Correct because both spray valves open causing a reactor trip on OT-delta-T or
LOW Pressurizer Pressure, followed by SI.
D. Incorrect because POW-I456 does not open.
008 Pressurizer Pressure Control
AA2.03: Ability to determine and interpret the following as they apply to the pressurizer
vapor space accident: PORV logic control under low-pressure conditions.
Surry Nuclear Plant 2804-301
DRAFT RO lnital Exam
8. 008K1 02 001/2/1/C'CJV/MEM
.
.. 3.3/3.4/B/SRC14301/R/MAR/SDR
-
Which ONE of the following correctly describes loads cooled by the Compnent
Cooling Water (CCW) System or subsystem of CCW?
A. RCP bearing lube oil coolers, neutron shield tank coolers, WCP seal water return
cooler, outside recirc spray pump seals.
B. HHSl pump seals, LHSI pump seals, WHR pump seals, RCP motor air C O S ~ ~ K S .
CY RHR pump seals, WCP bearing lube oil coolers, neutron shield tank coolers, HHSl
pump seals.
D. LHSI pump seals, RHR pump seals, WCP motor air coolers, neutron shield tank
coolers.
Surry
R&?El-8C?.
ND-88.5-LP-1, Component Cooling, Rev. 19
ND-88.3-LP-5, Charging System, Rev. 16
Distractor Analysis:
A. Incorrect because outside recirc spray pump seals are not cooled by CC.
B. Incorrect because LHSl pump seals are not cooled by CC.
6.
Correct because all are cooled by CC or a subsystem.
D. Incorrect because LWSl pump seals are not cooled by CC.
Wequal Bank Question #52%
008 Component Cooling
K1.02: Knowledge of the physical connections and / or cause-effect relationships
between the CCWS and the fallowing systems: Loads cooled by CCWS.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
9.
008K4.0 1 001/2/1/Ce)MPOhXNT
C00LllNGMEM 3.113 3/B/SK04301/R/MAR/STPK
.-.
Ten seconds after a Safety Injection occurs, the "A" Component Cooling Pump trips.
Which ONE of the following describes the operation of the CC pumps?
A:' The "B" CC pump will not auto start without a required operator action.
B. The "B" CC pump will auto start 60 seconds after the "A" CC pump trips.
C. The "B" CC pump will auto start as soon as the "A" CC pump trips.
B. The "B" CC pump will auto start 50 seconds after the "A" CC pump trips.
~.
_ _
-
-~
Sllrry
References:
NB-88.5-LP-1, Component Cooling Water System, Rev. 19.
Distractor Analysis:
A. Correct because Auto Start inhibit due to SI wiEl prevent auto start of the CC pump,
but the pump may be manually started at any time.
B. Incorrect because the Auto Start inhibit will block the auto start.
C. Incorrect because the Auto Start Inhibit will block the auto start.
B. Incorrect because the Auto Start Inhibit will block the auto start.
IbT Bank Question # 537
008 Component Cooling Water System
K4.01: Knowledge of CCWS design feature(s) and/or interlock(s) which provide for the
following: Automatic start of standby pump.
Surry Nuclear Plant 2084-381
DRAFT RO lnital Exam
I
- Dilution tocriticality has just been completed
~
Operators note that inadequate proportional heaters appear to be energized
I
10. Oi0AI.OE ~ 1 R I i I B O R O N
PZR SPRAY/C/A 2 . 8 / 2 . 9 / N / S R 0 4 3 0 1 / W ~ ~ ~ / S ~ ~
-
_.
I
The following plant conditions exist:
- Pressurizer Pressure is 2230 psig.
Which ONE of the following could result from inadequate Pressurizer Heater output
during a dilution to criticality?
(Assume all other controls and components working properly in their normal
configuration.)
A:' Boron concentration will be higher in the Pressurizer than in the RCS.
B. Boron concentration will be lower in the Pressurizer than in the RCS.
C. Pressurizer and WCS boron concentration will be approximately equal.
D. The Pressurizer Spray Nozzle will be susceptible to thermal shock.
-
_.
~-
..
__
Suray
References:
1 -GOP-l.l, Unit Startup, WCS Heatup From Ambient to 195 Degrees F, Rev. 25
Distractor Analysis:
A. Correct because RCS boron will be lower due to the dilution. The Pzr will still be at
a higher boron concentration until spray flow has created enough out-surge to
adequately equalize the boron with the RCS. (Lack of heaters creates la& of
sprays.)
B. Incorrect because boron concentration will be higher in the Pzr.
C. Incorrect because the lack of heater output will not allow for adequate mixing.
D. Incorrect because the bypass spray valves are normally open, which is sufficient to
prevent thermal shock. (Have utility verify that this is in fact the normal
csnfigu ration .)
01 0 Pressurizer Pressure Control
Al.81: Ability to predict and / or monitor changes in parameters (to prevent exceeding
design limits) associated with operating the Pnr PCS controls including: BZR and RCS
boron concentration.
Sslrry Nuclear Plant 2004-301
DRAFT RO lnitaf Exam
1 1. 01 1FiAl.13 001/1/1/SAI;T:TY INJF;.CTION/C/A 4 1/4,2/N/SIP04301/K/MAR/SDK ._
~.
Given the following conditions:
- LOCA has occurred
- WCS subeooling is 0 O F
~
RWST Level = 15% and slowly decreasing
- Containment Pressure = 9 psig and decreasing
~ Safety Injection Actuation has been reset
Which ONE of the following is the correct action to be taken'?
A. Close Charging Pump Miniflow Recirc Valves. With RWST Bevel at 15% push both
RMT pushbuttons for each train if automatic transfer does not occur.
B:' Close Charging Pump Miniflow Recirc Valves. When WWST level reaches 13%,
push both RMT pushbuttons for each train if automatic transfer does not occur.
C. With RWST level at 15%, push both RMB pushbuttons for each train if automatic
transfer does not occur. Secure Containment Spray Pumps immediately following
verification of Phase 1 and 2 RMT.
D. With RWST level at 13%, push both RMB pushbuttons for each train if automatic
transfer does not occur. Secure Containment Spray Pumps immediately following
Verification of Phase 1 and 2 RMT.
__
§wry Nuclear Plant 2004-301
DRAFT RO lnital Exam
Surry
References:
ND-95.3-LP-7, E-1 Loss of Reactor OF Secondary Coolant, Rev. 14
1 -El, Loss of Reactor
Secondary Coolant, Rev. 21
1 -ES-I 3,
Transfer to Cold beg Recirculation, Rev. 12
Distractor Analysis:
A. Incorrect because RMT transfer should not occur at 15%. It will occur at 13.5% and
procedurally should be verified at 13%.
B. Correct because verifications should be made at 73% and manually initiated if
needed (directed by ES-1.3).
C. Incorrect per ES-1.3 spray pumps should not be secured until they show signs of
cavitation. Also E-1 does not call for spray to be secured until containment
pressure is less than 12 psia. Also, RMT transfer should not occur at 15%.
D. Incorrect per ES-I .3 spray pumps should not be secured until they show signs of
cavitation. Also E-1 does not call for spray to be secured until containment
pressure is less than 12 pia.
Surry ILT Bank Question # 872
Of 1 Large Break LOCA
EA1 .I 3: Ability to operate and monitor the following as they apply to a large break
LQCA: Safety Injection Components.
Srurry Nuclear Plant 2004-301
DRAFT WO lnital Exam
12. 01 1K6.06 001/2/2/CHARGIhT
_. PWSSLKIZEWMEM
_.
____
2.5/2.8/~/d/SR04301IRIMAD/SL)R
-
Due to a controller failure, the Unit I Operator places the Charging Flow Controller to
MANUAL to control charging flow. A high Pressurizer Level causes the Operator to try
to reduce charging flow to 20 gpm.
Which ONE of the following correctly describes the behavior of FCV-I 122 when the
Operator attempts to reduce charging flow to 20 gpm?
A! The Flow Limit Summator no longer limits flow and FCV-I 122 can be manually
closed to allow 20 gpm flow.
B. The Flow Limit Summator no longer limits flow, however, FCV-1122 can only be
manually closed to allow 25 gpm flow.
C. The Flow Limit Summator will prevent FCM-I 122 from being closed past 25 gpm
fklw.
D. The Flow Limit Summator wilE prevent FCV-1122 from being closed past 30 gpm
fisw.
._
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
Surry
References:
ND-33.3-LP-7, Pressurizer Level Control System, Rev. 6
Distractor Analysis:
A. Correct because when the Charging Flow Controller is in MANUAL, the Flow Limit
Summator no longer limits the maximum and minimum values of charging.
Therefore FCV-1122 can be closed manually to any value.
5. incorrect because when the Charging Flow Controller is in MANUAL, the Fiow Limit
Summator no longer limits the maximum and minimum values of charging.
Distractor is incorrect because FCV-1122 may be manually closed to any value,
even below 25 gprn flow. Distractor is plausibe because candidate may not know
that FCV-I 122 may be throttled to any value with controller in MANUAL.
6. Incorrect because when the Charging Flow Controller is in MANUAL, the Flow Limit
Summator no longer limits the maximum and minimum values of charging. The
distractor states that the Flow Limit Summator will limit flow, which is contrary to the
fact that it wilt not limit flow. Distractor is plausible because candidate may not
know that the Flow Limit Summator does not function with controller in MANUAL.
D. Incorrect because when the Charging Flow Controller is in MANUAL, the Flow Limit
Summator no longer limits the maximum and minimum values of charging. The
distractor states that the Flow Limit Summator will limit flow, which is contrary to the
fact that it will not limit flow. Distractor is plausible because candidate may not
know that the Flow Limit Summator does not function with controller in MANUAL.
01 1 Pressurizer Level Control
K6.06: Knowledge of the effect of a loss or malfunction ow the foilowing will have on
the PZW LCS: Correlation of demand signal indication on charging pump flow Valve
controller to the valve position.
Surry Nuclear Plant 2804-301
DRAgF RO lnital Exam
13. Q12A4.04 001RIIIKPS 'I'COLD TEMP/C/A 3 3/3.3/B/SR0430I~Mi\\B/SDB
~
__
-
"A" Loop Narrow Range Tcold fails low while the reactor is at 100%.
Which ONE of the following will occur'?
A. Rod Insertion Limit Low and Extra Low alarms will be received.
B. Ch 1 OTDT setpoint will decrease.
I
C:' "A" Loop Delta T Protection Bistable will trip.
D. The Pavg I Tref Deviation alarm wiBl be received.
I
Surry
References:
NB-33.3-LP-2, Delta P / Tavg Instrumentation System, Rev. 9
MD-93.3-LP-3, Rod Control System, Rev. 14
Distractor Analysis:
A. lncorrect because failed Tcold is filtered out by Median Signal Selector.
B. lncorrect because OTDT setpoint will actually increase.
C. C~rrect because Tcold is fed directly to the RPS even when failed low.
B. lncorrect because failed Tcold is filtered out by Median Signal Selector.
654.04: Ability to manually operate and / or monitor in the control room: Bistables, trips,
resets. and test switches.
Surry Nuclear Plant 2004301
DRAFT RO lnital Exam
..
-~
1 4. 01X1.05
001/2/1/AWISAC&lEM
. _
3.8/3.9/BISR04301/~~/S~~
Which ONE of the following lists the method by which AMSAC causes a reactor trip?
A. Tripping the reactor trip and bypass breaker shunt coils.
B. Tripping the reactor trip and bypass breakers UV coils.
C. Tripping the rod drive MG set output breakers.
D!' Tripping the rod drive MG set supply breakers.
Sur9
Ref ere wces:
ND-93.3-LP-17, Anticipatory Mitigating System Actuating Circuitry, Rev. 18.
Distsactor Analysis:
A. Incorrect because this does not occur.
B. Incorrect because this does not occur.
e. Incorrect because this does not occur.
D. Correct becasue this is as stated in ND-93.3-LP-17, Rev. 10.
01 2 Reactor Protection System
K1.05: Knowledge of the physical connections and / or cause-effect relationships
between the RPS and the following systems: ESFAS
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
___
15. 013113.02 001/2/I/SAFETY
. _ INJEC1'IOhXVIEM 4.1/4.2/N/SIP03301/K/M..aBISDR
_ _
Which ONE of the following correctly states automatic actions that would occur given a
Unit 1 Low Pressurizer Pressure Safety Injection Signal being present for 5 minutes?
8. Hydrogen Analyzer Heat Tracing energizes AND Containment Vacuum Pumps trip.
B. Pressurizer Liquid Sample (SS-TV-l00A) receives a dose signal AND Motor Driven
A M Pumps start after a 45 second time delay.
6:'
Accumulator Nitrogen Relief Lines (SI-TV-1 OlA,B) receive a close signal AND
Primary Drain Transfer Bank Vents (VG-TV-1 89A/B) receive a close signal.
D. Main Steam Trip Valves (MS-TV-I 01 NBICJ receive a close signal AND Seal Water
Return Valve (MOV-381) receive a close signal.
Surry
References:
ND-91 -kP-2, Safety Injection System Description, Rev. 16
NB-91 -LP-2, Safety Injection System Operations, Rev. 15
P&lD 1 1448-FM-068A9 FlowNalve Operating Numbers Diagram Feedwater System
Surry Power Station Unit 1, Rev. 57
Distractor Analysis:
A. Incorrect because SI signal must be present for 8 minutes for heat trace to
E3. Incorrect because MDAFW Pump starts after 50 sec delay.
C. Correct because both get a close signal on any SI Signal.
3. Incorrect because MSTVs only get a close signal on a High Steam Flow SI Signal.
energize.
01 3 Engineered Safety Features Actuation
A3.02: Ability to monitor automatic operation of the ESFAS including: Operation of
actuated equipment.
Surry Nuclear Plant 2004-301
DRAFT RO tnital Exam
Which ONE of the following could occur it ES-1.4, Transfer to Hot beg Recirculation, is
performed 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> after the start of it Large Cold Leg Break LQCA?
A. Debris from the In-Core sump could block coolant flow by blocking the lower core
plate.
B. Reflux cooling could be lost due to boron precipitation in the hot leg nozzles.
C. Fouling of core heat transfer surfaces due to the dilution of boric acid.
D? Reduction in size of the incsre coolant flow channels due to boron precipitation.
References:
ND-95.3-LP-11, ES-I .4, Transfer To Hot keg Recirculation, Rev. 8
ES-I .4, Transfer To Hot Leg Recirculation, Rev. Si
Distractsr Analysis:
A. Incorrect because debris in the sump will not block water discharged from the SI
B. Incorrect because ~QKH-I
precipitation is a concern in the core, not the hot legs.
C. Incorrect because fouling of core heat transfer surfaces is a result of boron
precipitation, not dilution.
D. Correct because boron precipitation is a concern when boil-off continues and when
core temperature decreases. The standard time for transfer to hot leg secirc is 8
hours, not 20 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br />, as stated in the stem.
pumps.
01 3 Engineered Safety Features Actuation
K3.06: Knowledge of the effect that a loss or malfunction of the ESFAS will have on
the following: Fuel
Surry Requal Bank Question #299
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
The following Unit 1 conditions exist:
- A Small Break LOCA has occured
- Automatic Safety Injection has occurred
- 1 -E-0, Reactor Trip or Safety Injection, has been implemented
- The CRO observes the Rod Position Indication as displaying Control Rods on the
bottom of the reactor core, with the exception of three Control Rods.
Which ONE of the following actions is procedurally required as a result of this finding
by the CRO?
A:' Continue with 1 -E-O, Reactor Trip or Safety Injection.
B. Emergency borate while proceeding through 1 -EO, Reactor Trip or Safety Injection.
e. Manually insert control rods while proceeding through 1 -E-O, Reactor Trip or Safety
Injection.
D. Go directly to 1 -FR-S. 1
~ Response to Nuclear Power Generation / ABWS, Step 1
Surry
References:
1 -FR-S. 1, Response to Nuclear Power Generation / ATWS, Rev. 18
7-E-0, Reactor Trip or Safety Injection, Rev. 46
Distractor Analysis:
A. Correct because E-Q should be entered upon Reactor Trip per the rules of EOP
usage.
B. Incorrect because if emergency bsration is needed, it will be directed by FR-%.I.
C. Incorrect because if manual rod insertion is needed, it will be directed by FR-S.1.
D. Incorrect because FR-S.1 should only be entered as directed by E-0 (or if E-0 has
been completed then an Orange or Red path).
014 Rod Position Indication
A2.05: Ability to (a) predict the impacts of the following malfunctions or operations on
the RPIS; and (b) based on those predictions, use procedures to correct, control, or
mitigate the consequences of those malfunctions or operations: Reactor Trip.
Surry ILT Bank Question #lo37
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
1
1 8. - 0 15K34.04 00 lI2/2IPERhlISSIVE/GIA -
3.7/3.8/N/SIp0430
- 1IKIMABISLX
-
__
The following Unit 1 conditions exist:
- Reactor Power is 5%
- Turbine First Stage Impulse Pressure PT-446 is selected
- Power Range Nuclear Instrument N-41 fails high
- PT-446 fails high
Which ONE of the following correctly describes the impacts of the failures?
A. Control Rods do not move. The Reactor Protection System At-Power Trips are
enabled due to the N-41 failure.
B. Control Rods step out at 72 steps per minute. The Reactor Protection System
At-Power Trips are enabled due to the N-41 failure.
I
C. Controf Rods do not move. The Reactor Protection System At-Power Trips are
enabled due to the PT-446 failure.
DI Control Rods step out at 72 steps per minute. The Reactor Protection System
At-Power Trips are enabled due to the PT-446 failure.
Surry
References:
ND-93.3-LP-16, Per~issive/Bypass~$rip
Status Lights, Rev. 8
Surry Simulator Malfunction Cause and Effects, Rev. 6, Malfunction MMS-I 4
Distractor Analysis:
A. Incorrect because Tref will go to 574 O F , which will cause rods to step out at max
rate of 72 stepshin. Also incorrect because 2/4 PR Nls must be above 10% to
enable At Power Trips.
B. Incorrect because 2/4 PI3 Nls must be above 10% to enable At Power Trips.
C. Incorrect because Tref will go to 574 OF, which will cause rods to step out at max
rate of 72 steps/rnin.
B. Correct because Tref will go to 574 O F , which will cause rods to step out at max rate
of 72 steps/rnin and only 1/2 Turbine First Stage PTs need to be above 10% to
enable At Power Trips.
01 5 Nuclear instrumentation
K4.07: Knowledge of NIS design feature@) and /or interlock@) provide for the
following: Perrnissives.
Susry Nuclear Plant 2004-301
DRAFT RO lnital Exam
1
19. 016A4.01 001/2/2/PIMP
..
IhllPUI SE/C/A 2 . 9 / 2 . 8 / U / S R 0 4 3 0 1 ~ ~ / S D R
- .-
The following condition exists:
- Unit 1 at 100% reactor power
- All systems and equipment functions as designed
- All protection channel ill's are selected
- First stage impulse pressure channel IV fails low
Which ONE of the following would occur initially without operator action?
A. AMSAC would be operationally disabled after 60 seconds.
B. Steam Dumps would all open.
6. FRVs would control SG level at no load level.
D:' MOV-CP-100, Condensate Polishing Building Bypass Valve, would open.
Surry
References:
ND-53.3-LP-17, Anticipatory Mitigating System Actuating Circuitry (AMSAC), Rev. 10
ND-93.3-LP-9, Steam Dump Control System, Rev. 10
ND-53.3-LP-8, SG Water Level Control System, Rev. 6
Distractor Analysis:
A. Incorrect because this would occur after 360 seconds.
B. Incorrect because Channel Ill is selected.
6. Incorrect because Channel Ill is selected.
D. Correct because, as stated in ND-93.3-LP-9, 6B-100 will open in anticipation of the
upcoming increase in feedwater flow that will occur during load rejection.
01 6 Non-Nuclear Instrumentation
A4.81: Ability to manuaily operate and / or monitor in the control room: NNl channel
select controls.
Surly Requal Bank Question #275
Surry Nuclear Plant 2804-301
DRAFT RO lnital Exam
20. 022AK 1.5 1 50 11'1 IIIRCP SEhLSICI.4 2.8/3.2/N/SR5435 IiRMARISDR
The following Unit 1 conditions exist:
~
Reactor trip has occurred due to a loss of all A 6 power
- Power has been restored
- The following Reactor Coolant Pump parameters are present for all RCPs:
- No. 1 Seal Water Outlet Temperatures are 225 O F
- Lower Seal Water Bearing Temperatures are 220 O F
1 -AP-9.02, toss of RCP Seal Cooling.
- The Shift Supervisor directs %he operators to restore cooling to the RCP seals per
Which ONE of the following correctly states the requirements for restoring cooling to
the WCP seals and why?
A. Bo not establish seal injection flow or component cooling Blow to the thermal barrier
heat exchanger because the No. 1 Seal Water Outlet Temperatures are too high.
Seal cooling should be restored by coding the RCS using natural circulation.
B. Bo not establish seal injection flow or component cooling flow to the thermal barrier
heat exchanger because the Lower Seal Water Bearing Temperatures are too high.
Seal cooling should be restored by cooling the RCS using natural circulation.
6. Slowly establish seal injection flow to minimize RCP thermal stresses, followed by
slowly introducing component cooling flow to the thermal barrier heat exchanger to
limit introduction of steam into the CC system.
D:' Siowly establish component cooling flow to the thermal barrier heat exchanger to
limit introduction of steam into the CC system, followed by slowly introducing seal
injection flow lo minimize the RCP thermal stresses.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
Surry
References:
1-AP-9.02, Loss of RCP Seal Cooling, Rev. 8.
ND-88.1 -b$-B, Reactor Coolant Pumps, Rev. 16.
Distractor Analysis:
A. Incorrect because AP-9.02 (Caution page 7) states if No. 1 Seal Water Outlet Temp
is 9 235 'F then Seal Inj and CCW to Thermal Barrier H.X. should not be restored.
Instead N.C. should be used to cool the seals.
Temperature is 9 225 "F then Seal Inj and CCW to Thermal Barrier H.X. should not
be restored. Instead N.C. should be used to cool the seals.
C. Incorrect because CC flow should be established prior to seal injection flow.
D. Correct as stated in 1 -AP-9.02 NOTE prior to step 7 and CAUTIONS prior to steps 9
B. Incorrect because AQ-9.02 (Caution page 7) states if Lower Seal Water Bearing
and 15.
022 boss of Rx Coolant Makeup
AK1.01: Knowledge of the operational implications of the following concepts as they
apply to boss of Reactor Coolant Pump Makeup: Consequences of thermal shock to
WCP seals.
Surry Nuclear Plant 2004-301
DRAFT RO Inital Exam
Unit 1 has tripped and Safety Injection has actuated due to a Large Break Loss of
Coolant Accident (LOCA).
Many complications have occurred.
The crew has exited E O , Reactor Trip or Safety Injection. The Shift Technical Advis
has star3ed to monitor Critical Safety Function Status Trees and reports:
Subcriticality
~ Orange Path
~ Heat Sink - Yellow Path
- Core Cooling - Orange Path
- Containment - Red Path
Which ONE of the following states the correct procedure transition?
A. FR-S.1 Response to Nuclear Power Generation/ATWS, based on Subcriticality
Orange Path.
3. FR-H.1, Response to Secondary Heat Sink, based on Heat Sink Yellow Path.
C. FR-C.1, Response to Inadequate Core Cooling, based on Core Cooling Orange
Path.
B I FR-Z.1, Response to High Containment Pressure, based on Containment Red
Path.
Surry Nuclear Plant 2004-301
DRAFT RO inital Exam
References:
ND-95.3-LP-26, Critical Safety Function Status Trees, Rev. 5
Distractor Analysis:
A. incorrect based on the rules sf use for safety function status trees (ND-95.3-LP-26
Page 15). The Subcriticality Orange Path does not take priority over any Red Path.
B. Incorrect based on the rules of use for safety function status trees (ND-95.3-bP-26
Page 15). The Heat Sink Yellow Path does not take priority over Containment Red
Path.
C. Incorrect based on the rules of use for safety function status trees (ND-95.3-LP-26
Page 15). Core Cooling Orange Path does not take priority over Containment Red
Path.
D. Correct based on the rules of use for safety function status trees (ND-95.3-LP-26
Page 15). The Containment Red Path takes priority over the other paths. Only
knowledge of safety function priority rules are needed to answer this question.
022 Containment Cooling
62.4.22: Knowledge of the bases for prioritizing safety functions during abnormal and
emergency operations.
Turkey Point Bank Question TP03301
Surry Nuclear Plana 2004-301
DRAFT RO Inital Exam
- _ _
22. 022K3.02 ___
001/2/1/CONTAIN,MENT PRE:SSURWC/A 3 . 0 / 3 ~ H 0 4 3 5 1 I T P I M ~ / ~
__
~
--
__
~
~
Unit 2 is operating at 100% power with Chilled CC in service to containment.
2-CD-REF-1 A trips due to a fault.
Which ONE of the following describes the effect on Unit 2 containment parameters?
A. Indicated partial pressure will increase. Containment temperature will decrease.
B. Indicated pariial pressure will increase. Containment temperature will increase.
C. Indicated partial pressure will decrease. Containment temperature wili decrease.
D:' Indicated partial pressure will decrease. Containment temperature will increase.
-___
~
-~
~
~-
-~
~~
Surry (Utility should add noun names to equipment in the stern.)
References:
ND-88.5-LP-1, Component Cooling, Rev. 19
Distractor Analysis:
A. Incorrect because partial pressure will decrease due to toss of chilled CC.
B. Incorrect because partial pressure will decrease due to loss of chilled CC.
C. lncsrrect because containment temperature will increase due to a Boss of chilled
El. Correct because partial pressure will decrease and containment temperature will
ec.
increase due to a loss of chilled CC.
Bank Question # 544
022 Containment Cooling
K3.02: Knowledge of the effect that a loss or malfunction of the CCS will have on the
following: Containment lnstsument Readings.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
The following Unit 1 conditions exist:
- A Large Break LOCA has occurred inside containment
- Safety lnjection has actuated
- Containment Pressure peaked at 28 psia
- Current Containment Pressure is 15.8 psia
- "1 A', "28" and "2B" Recirculation Spray Pumps are operating
- "I B" Recirculation Spray Pump tripped on Overload (Ob)
- lA-E%, RS PP 1A VIB, annunciates and the alarm cannot be cleared
Which ONE of the following states the correct operator action for these conditions?
A. Secure Recirculation Spray Pump "1A8'
using the handswitch in the control room.
B! Place the Recirc Spray Pump 1A in PTL, then secure Recirculation Spray Pump
"1A" lsealfy at the breaker (14H4).
6. Reset CLS, then place the handswitch for Recirculation Spray Pump "I A" in PTL.
B. Allow Recirculation Spray Pump "I A to operate, but monitor vibrations closely.
Sur9 Nuclear Plant 2004-301
DRAFT RO lnital Exam
References:
ND-91 -LP-5, Containment Spray System, Rev. 13
NB-91-LP-6, Recirculation Spray System, Rev. 9
I-RM-A7, RS/SW HX A ALEWT/FAILURE, Rev. 5
Distractsr Analysis:
A. Incorrect because with CLS present, the handswitch in the control room cannot be
used to secure the pump. Containment pressure must be less than 12 psia to reset
CLS. Pressure currently is 15.8 pia.
B. Correct because Escal operation of the breaker will stop the pump. In addition, the
ARP will have the operator place the handswitch in PTL, but the lesson plan
(ND-91 -LP-6 Page 6) states that the pump cannot be secured from the control
room with CLS present. Furthermore, the ARF gives guidance to secure the
distressed pump as long as two other WS Pumps are operating. The stem states
that two other pumps are operating ("2A" and "25").
C. Incorrect because the CLS cannot be reset until containment pressure is less than
I2 psia.
D. Incorrect because the ARP gives guidance to secure the distressed pump as long
as two other RS Pumps are operating. The stem states that two other pumps are
operating ('24" and "25").
A2.07: Ability to (a) predict the impacts of the following malfunctions or operations on
the CSS; and (bj based on those predictions, use procedures to correct, control: or
mitigate the consequnces of those malfunctions or operations: Loss of containment
spray suction when in recirculation mode, possibly caused by clogged sump screen,
pump inlet high temperature (exceeded cavitation, voiding), or sump level below cutoff
(interlock) limit.
Note:
The AWP states that high vibration alarms may be caused by cavitation of the pump.
Cavitation could be caused by high water temp, low water level, etc.
Surry Nuclear Plant 2084-381
DRAFT RO lnital Exam
A High Steam Flow Safety Injection Signal is received.
Which ONE of the following correctly describes the response of the Component
Cooling Water System components?
A.' PV-CC-lO9A and E3 (CC Isolation Valves from RHR) close and TV-CC-I 10A, B, an(
C (Reactor Cont Air Recirc Cooler CC Outlet Flow Outside Trip Valve) remain as-is
B. TV-CC-109A and B (CC isolation Valves from WHW) remain as-is and TV-CC-I lQA
B, and 6 (Reactor Cont Air Recirc Cooler CC Outlet Flow Outside Trip Valve)
remain as-is.
C. TV-CC-lQ9A and B (CC isolation Valves from RHR) close and TV-66-1 1014, B, anc
C (Reactor Cont Air Recirc Cooler CC Outlet Flow Outside Trip Valve) close.
D. TV-CC-109A and B (CC Isolation Vahes from RHR) remain as-is and BV-CC-I 1QA
B, and C (Reactor Cont Air Recirc Cooler CC Outlet Flow Outside Trip Valve) close
Surry
References:
88-05-01, Component Cooling Water System, Rev. 19
Distractor Analysis:
A. Correct because lesson plan states CC-109 closes on Phase I and 1 10 closes on
B. Incorrect because lesson plan states CC-109 closes on Phase I and 1 18 only closes
C. Incorrect because lesson plan states CC-109 closes on Phase I and 1 10 only
D. Incorrect because lesson plan states CC-109 closes on Phase I and 110 closes on
Phase Ill isolation.
on Phase Ill isolation.
closes on Phase III isolation.
Phase III isolate.
026 Loss of Component Cooling
AK3.02: Knowledge of the reasons for the following responses as they apply to Loss of
Cooling Water: The automatic actions (alignments) within the CCWS resulting from the
actuation of the ESFAS.
The loss of CCW occurs in part of the system due to the ESFAS isolation of
PC-CC-I 09NB.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
The following Unit 1 conditions exist:
- A Large Break LOCA has occurred
- Safety Injection has actuated
- Containment Pressure peaked at 27 psia
- RCS subcooling is 0 O F
- Steam Generator Levels are 22% and slowly risimg
- RWSP emptied while performing ES-1.3, Transfer to Cold Leg Recirculation
- ES-I 3, Transfer to Cold Leg Recirculation, has been completed and the crew has
- All equipment operated normally
transitioned back to E-1 , Loss of Reactor or Secondary Coolant
Which ONE of the following alarms is consistent given the above plant conditions?
A. 1 E-A1 , HI-HI CTMT PRESS CLS CH-1
E!:'
1 B-Bl , CS PP 1A LOCKOUT QR OL TRIP
C. 1A-D7, RS PP 1A LOCKOUT OR Ok TRIP
B. 1 BF6, CTMT INST AIR HDR LO PRESS
Surry Nuclear Plant 2004-381
DRAFT 88 lnitaf Exam
Surry
References:
1 -El, Loss of Reactor or Secondary Coolant, Rev. 21
1 4 3 - 1 3,
Transfer to Cold Leg Recirculation, Rev. 12
1 B-B1, CS PP1A LOCKOUT OR OL TRIP, Rev. 0
1 B-F6, CTMT INST AIR HDR LO PRESS, Rev. 1
ND-91 -kP-5, Containment Spray System, Rev. 13
ND-9t -LP-6, Recirculation Spray System, Rev. 9
1 E-AI, HI-HI CTMT PRESS GLS CH-1, Rev. 0
1A-D7, RS PP 1A LOCKOUT OR OL TRIP, Rev. 8
Distractor Analysis:
A. Incorrect because containment pressure is now less than the setpoint, which is
known by CLS having been reset. As a part of going to Cold Leg Recirc, CLS and
SI must be reset.
B. Correct bemuse 1 -ES-l.3
has been completed and the RWST has been emptied;
therefore, the @S Pumps would be placed in PTb due to the lack of a suction
source (cavitation). Placing the CS Pumps in PTL yields 1 B-Bl for CS Pump IA.
AUTO when stopped.
and instrument air would have been restored to containment.
6. Incorrect because Outside Recirc Spray Pump 1 A would be placed in
B. Incorrect because CLS and SI must Rave been reset prior to completion of 143-1 3
G2.4.46: Ability to verify that alarms are consistent with plant conditions.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
Which ONE of the following describes the operation of the lodine Filtration Fans
(1 -VS-F9N35)?
A. Automatically start on a Hi-Hi CLS.
B. Automatically start on a containment gas high alarm.
C. Automatically stop on a Hi-Hi CLS signal.
BT' Must be manually started under all conditions.
~
~
~
.~
__
~
~
~
-~
~
~
Surry
References:
ND-88.4-LP-6, Containment Ventilation, Rev. 5
Distractor Analysis:
A. Incorrect because Bans are only manually operated.
B. Incorrect because fans are only manually operated.
C. Incorrect because fans are only manually operated.
D. Correct because fans are only manually operated.
029 Containment Iodine Removal
A4.03: Ability to manually operate and / or monitor in the control room: ClRS fans.
Question Status:
Surry Bank ILT Question #741
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
The following Unit 1 conditions exist:
- The Reactor is at 100% Power.
- A malfunction in the Pressurizer Heater Control Circuit has resulted in Proportional
Heaters being de-energized.
- A small amount of leakage in the Pressurizer Auxiliary Spray Valve is occurring.
- Pressurizer Pressure is 2215 psig and slowly lowering.
1-AP-31 .QO, Increasing or Decreasing RCS Pressure, has been entered.
Which ONE of the following states the correct position of the normal sprays and
backup heaters?
A. Normal sprays are OFF (valves closed) and backup heaters are ON.
B. Normal sprays are ON (valves open) and backup heaters are OFF.
CY Normal sprays are OFF (valves closed) and backup heaters are OFF.
D. Normal sprays are ON (valves open) and backup heaters are ON.
Surly
References:
ND-93.3-LP-5, Pressurizer Pressure Control, Rev. 9
1 -AP-31 .00, increasing or Decreasing RCS Pressure, Rev. 6
Distractor Analysis:
A. Incorrect because backup heaters do not energize until 2210 psig.
5. Incorrect because spray valves do not start to open until 2255 psig.
C. Correct because backup heaters do not energize until 2210 psig and spray valves
D. incorrect because backup heaters do not energize until 221 8 psig.
do not open until 2255 psig.
027 Pressurizer Pressure Control System Malfunction
AK3.01: Knowledge of the reasons for the following responses as they apply to
pressurizer pressure control malfunctions: Isolation of PZR spray following loss of PZR
heaters.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
2%. - -
02862.2.12 GQ1/2/2/HYDROGEN
~
_
_
~
-
RBCOMBINER/C/A 3.0/3.iflNISK04301/RAB/SDR
~~~~~
-
The following Unit 1 conditions exist:
- The plant is at 50% power
- 1 -PT-37.2, Electric Hydrogen Recombiner, is about to be performed to determine the
reference power that would be used in the event that the Recombiners are used
following a LBCA.
Which ONE of the following correctly states 1 -PP-37.2 limitations that are applicable
during the performance of this test?
A:' At no time should the heater temperature be allowed to exceed 1408 O F as
monitored by the highest thermocouple reading AND containment hydrogen
concentration must be verified to be less than 0.75%.
B. At no time should the heater temperature be allowed to exceed 1400 QF as
monitored by the highest thermocouple reading AND containment hydrogen
concentration must be verified to be less than 1.00%.
6. At no time should the heater temperature be allowed to exceed 1300 O F as
monitored by the highest thermocouple reading AND containment hydrogen
concentration must be verified to be less than 0.75%.
B. At no time should the heater temperature be allowed to exceed 1300 O F as
monitored by the highest thermocouple reading AND Containment hydrogen
concentration must be verified to be less than 1 .00%.
Surry Nuclear Plant 2004-301
DRAFT RQ lnital Exam
References:
4 -PT-37.2, Electric Hydrogen Recombiner, Rev. 9
Distractor Analysis:
A. Correct because these are both requirements listed on Section 4.0 of 1-PT-37.2.
The unit is at power, therefore 4.3 states that containment hydrogen concentration
must be verified less than 0.95% (being at power and making the operator
determine if 4.3 applies is par! of what makes the question C/A). Section 4.2 states
that heater temperature must remain less than 1400 O F at all times.
requirement. Plausible because applicant may not know that the requirement is
69.75%, vice 1 .0%.
C. Incorrect because verifying the highest temperature less than 1388 O F is not the
correct requirement. True - if the operator ensures temperature is less than
1300 O F , then he has also ensured that it is less than 14QO O F , but this question
tests the knowledge of the requirement, not simply a method for meeting the
requirement. Plausible because applicant may not know the temperature
requirement.
B. Incorrect because verifying containment hydrogen less than 1% is not the correct
D. Incorrect because of reasons in C and D distractor analysis.
028 Hydrogen Recsmbiner and Purge Control
G2.2.12: Knswl&ge of surveillance procedures.
09 001/1/1/
-.
Scsrry Nuclear Plant 2004-301
DRAFT RO lnital Exam
Which ONE of the following describes the reason why charging pump suctions are
manually aligned to the RWST during an ATWS vice manually initiating a Safety
Injection?
A. Prompt operator action will ensure the most direct method of laorating into the P
and manual alignment of charging pump suction to the RWST prevents
compounding the problem by charging the RCS solid via Safety Injection.
B. Prompt operator action will ensure the most direct method of laorating into the R
and initiation of SI would reduce the possible paths for emergency boration and
to an RCS overpressure condition if one exists.
C. Manual initiation of Safety Injection would delay the addition of borated water to
RCS and complicate the recovery actions. Alignment of charging pump suction
the WWST is the most direct method of borating the RCS.
D I Manual initiation of SI would result in the undesirable trip 69f Main Feedwater P u
and alignment of Charging Pump suction to the RWST is the most direct meths~
borating the RCS.
Surry Nuclear Plant 2804-301
DRAFT 80 lnital Exam
Surry
References:
ND-95.3-LP-36-DRf3, FR-SI Response to Nuclear Power Generation / ATWS, Rev. 10
FW-S. 1, Response to Nuclear Power Generation / ATWS, Rev. 15
Distractsr Analysis:
A. Incorrect because the concern with initiating SI is not creating a solid plant
condition, but with reducing the probability of maintaining a secondary heat sink
because MFW pumps will trip upon SI initiation.
E3. Incorrect because the concern with initiating SI is not creating a high RCS pressure
condition, but with reducing the probability of maintaining a secondary heat sink
because MFW pumps will trip upon SI initiation.
C. incorrect because manual initiation would not delay addition of borated water. The
concern is with reducing the probability of maintaining a seondary heat sink
because MFW pumps will trip upon SI initiation.
69. Correct because per NB-95.3-LP-36-DRR, FR-S.1 Response to Nuclear Power
Generation / ATWS, both of these statements accurately reflect the basis for Step
4-
029 ATWS
EK3.09: Knowledge of the reasons for the following responses as they apply to the
ATWS: Opening centrifugal charging pump suction valves from WWST.
Modified BLT Bank Question # 3390
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
38. 032AAl .0 1 00 1/1/2ISCl~lJRCE
INlEKMEDIATE/C/A 3.1/3 4/B/SRO430
-
~
_
_
1,IRIMABISDR
The following conditions exists:
- Present time is 1428 hours0.0165 days <br />0.397 hours <br />0.00236 weeks <br />5.43354e-4 months <br />
- Reactor tripped at 1405 hours0.0163 days <br />0.39 hours <br />0.00232 weeks <br />5.346025e-4 months <br />
- All Rod Bottom Lights are lit
- N-35 reading is 2 x I o- amps
- N-36 reading is 4 x 10-I amps
- Source Range is not energized
- Power level prior to trip was 90%
Which ONE of the following describes the correct actions given the above parameters?
A. When both IR channels read < 5 x ICY amps, verify source range channels
energized.
B. Place the source range trip bypass switches in the NORMAL position.
C: Energize the source range channels by depressing the source range manual reset
pushbuttons.
D. Transfer NR-45 to one source range and one intermediate range channel.
~
.~
-~
~
References:
ND-93.2-LP-3, intermediate Range Nfs, Rev. 10.
Distractor Analysis:
A. Incorrect because SW energizes at 2/2 IR < 5 x 10. amps.
B. Incorrect because SR should already be energized in the NORMAL position and this
action would not energize the SR.
C. Correct because l a are under-compensated and SR must be manually energized.
B. incorrect because SR should both be energized.
032 Loss of Source Range NI
AA1.01: Ability to sperate and / or monitor the following as they apply to loss of source
range nuclear instrumentation: Manual restoration of power.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
31. 033AA2
~
04
~ 001/1/2/OVERIAP
~
h x E M 3 2 1 3 . 6 ~ / S R ( J 4 3 0 1 / R / M N ~ / S ~ R ~
~
~
-1
The following Unit 1 conditions exist:
~ Critical approach has just been completed.
- Reactor is stable at the Point of Adding Heat.
- One Intermediate Range (la) Nuclear Instrument (NI) is suspected of displaying
1-
I
inaccurate indications.
Which QNE of the following correctly describes the expected Power Range (PR) NI
and the known operable IR Nl indications for the above conditions to verify that the
suspect IR NI is in fact falsely indicating?
BY 18 = 2.0 x
Amps; PR between 0.2 and 1 Yo
References:
ND-93.2-LP-4, Power Range Nls, Rev. 16
1 -GOP-I .4, Unit Stariup, HSD to 2% Reactor Power, Rev. 29
Distractor Analysis:
A. Incorrect because 2.5 x
3. Correct based on above two references: NB-93.2-LP-4 (Hn-4.3) & 1 -GOP-I .4
(Page 29 CAUTBON).
C. Incorrect because 1 .0 x lo-' Amps is about where critical data is taken (too low).
B. Incorrect because 1 .0 x
Amps is above the POAH and should correspond to
about 2% power.
Amps is about where critical data is taken (too low).
033 Boss of Intermediate Range NI
AA2.84: Ability to determine and interpret the following as they apply to the loss of
intermediate range nuclear instrumentation: Satisfactory overlap between
source-range, intermediate-range, and power-range instrumentation.
Surry Nuclear Plant 2004-301
DRAFT 80 lnital Exam
Unit 1 is in a refueling outage when the following events occur:
- Purge Isolation Valves (Moa/-VS-IOOA, B, C, and D) Close
~ Containment Instrument Air Suction Valves (PV-IA-101 N B ) Close
Which ONE of the following radiation monitors could have caused these actions?
Unit Purge Supply Fans (4A and 48) Trip
A. Process Vent Particulate and Gas Monitors (RM-RI-101 / 102)
B. RM-161 (Containment High Range Gamma Monitor)
CY RM-162 (Manipulator Crane Monitor)
D. RM-163 (Reactor Containment Area Monitor)
I
Sur9
References:
ND-93.5-LP-4, Pre-PMI Radiation Monitoring System, Rev. 5
Distractor Analysis:
A. Incorrect because RM-RI-101 i 102 do not cause these actions.
B. Incorrect because RM-I 61 does not cause these actions.
C. Correct per ND-93.5-LP-1.
B. Incorrect because RM-1 63 does nst cause these actions.
034 Fuel Handling Equipment
A4.01: Ability to manually sperate and / st monitor in the control room: Radiation
Levels.
Surry Nuclear Plant 2084-301
DRAFT WO Inital Exam
The following Unit 1 conditions exist:
- Plant is stable at 75% Power
- "A" SG Steam Line FT-MS-475 is selected for Steam Generator bevel control
- "Abi SG Steam Line PB-MS-475 fails high
Which ONE of the following correctly describes the impact on the "A" Steam Generat~r
bevel control?
A. Feedwater Regulating Valve opens because indicated steam flow is greater than
indicated feedwater flow.
BY Feedwater Reguiating Valve does not move as a result sf the failure.
6. Feedwater Regulating Valve closes because the pressure transmitter is
overcompensating For density.
I
D. Feedwater Regulating Valve opens to reduce the level error created by the failure.
Surry
References:
ND-93.3-LP-8, SG Water Level Control System, Rev. 6
B i st raclo r Analysis :
A. Incorrect because PT-MS-475 does not compensate steam flow for IFT-MS-475.
B. Correct because PT-MS-475 does not compensate steam fl0w for FT-MS-475.
C. Incorrect because PT-MS-475 does not compensate steam fiow for IT-MS-475.
D. Incorrect because PT-MS-475 does not cornpensate steam flow for FT-MS-475.
035 Steam Generator
A3.01: Ability to monitor automatic operation of the S/G including: S/G water level
CQntrOl.
_ __
-
Sur9 Nuclear Plant 2084-381
DRAFT RO lnital Exam
34. 0 3 8 E K 3 ~ 1 / 1 / I / S A R : 1 Y
~-
INJECTION//MEM 4.1/4.S/N/SK0430
~.
I/R/MAB/SDK
~-
Which ONE of the following is correct regarding safety injection termination during a
steam generator tube rupture event?
Safety Injection termination ..
A! may occur with total A
m
flow less than 350 gpm as long as 358 gpm is available.
B. may occur with Pressurizer level less than 22% as long as level is increasing.
6. may not not occur with a void in the reactor head due to presenting RCS pressure
control problems.
D. may not not occur with a void in the reactor head due to presenting RCS level
control problems.
References:
ND-95.3-LB-13, E-3 Steam Generator Tube Rupture, Rev. 11
1453, Steam Generator Tube Rupture, Rev. 19
Distractor Analysis:
A. Correct because if no intact SG is available the ruptured SG will be used to cool the
RCS. In this instance the AFW flow may be less than 358 gpm, but 350 gpm must
still be available to that SG. If sufficient flow is available, then SI termination criteria
is considered to be met (ND-35.3-LP-13).
B. Incorrect because pressurizer level must be greater than 22% to meet the SI
termination criteria.
C. Incorrect because safety injection may be terminated when there is a void in the
reactor head. This will present some challenges with RCS pressure and level
control, but it is not a large enough concern to prevent St termination if the specified
criteria are met (ND-95.3-LP-13).
D. lncorrect because safety injection may be terminated when there is a void in the
reactor head. This will present some challenges with RCS pressure and Devel
control, but it is not a large enough concern to prevent SI termination if the specified
criteria are met fND-95.3-kP-13).
038 Steam Gen. Tube Rupture
EK3.09: Knowledge of the reasons for the following responses as they apply to the
SGTR: Criteria for securing / throttling ECCS.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
With Unit 1 at 100% power, the Condenser Air Ejector and Main Steam Line Radiation
Monitor alarms are recieved. The Condenser Air Ejector Radiation Monitor reads 700
cpm (ALERT and H!GH alarms are in) while local Main Steam NRC Radiation Monitors
read "A" .03 mdhr, and "B" .01 mdhr, and "C" .01 mdhr. The Team has implemented
1-AP-16.00, Excessive RCS Leakage, and the RCS leak rate is determined to be 60
wm.
Which ONE of the following describes the actions required?
A. Verify automatic Condenser Air Ejector divert to Containment, intiate 1 -AP-24.00
(Minor SG Tube Leak), manually trip the reactor and go to 1-E-8 (Reactor Trip or
Safety Injection).
B. Verify automatic SGBD TV trip isolation and Condenser Air Ejector divert to
Containment, manually trip the reactor and initiate SI, Go to l-E-0.
C. Verify automatic Condenser Air Ejector divert to Containment, initiate 1 -AP-24.01
(Large Steam Generator Tube Leak), verify letdown isolated, and commence a
normal Unit Shutdown kh' GOPS.
5" Verify automatic Condenser Air Ejector divert to Containment, initiate 1 -AP-24.O1
(barge Steam Generator Tubs Leak), and manually trip the reactor and go to 1 -E-0.
Surry Nuclear Plant 2804-384
DRAFT RO lnital Exam
References:
ND-$9.3-LP-2, Main Condensate System, Rev. 16
ND-93.5-LP-3, Post-TMl Radiation Monitoring System, Rev. 6
1 -PIP-1 6.00, Excessive RCS Leakage, Rev. 1 1
1 -AP-24.00, Minor SG Tube beak, Rev. 8
1 -AP-24.0% Large Steam Generator Tube Leak, Rev. 1 1
Distractor Analysis:
A. Incorrect because 60 gpm leakage is more than minor. A$-24.01 should be entered
for a large steam generator tube leak.
B. lncorreet because Si should not be initiated.
C. incorrect because the reactor must be manually tripped with leakage greater than
50 gpm.
D. Correct because air ejectors will divert to containment on an air ejector high
radiation, AP-24.01 should be entered due to 60 gpm leak rate with air ejector high
radiation, and E-Q should be entered following a manual reactor trip.
039 Main and Reheat Steam
AI .09: Ability to predict and / or monitor changes in parameters (to prevent exceeding
design limits) associated with operating the MRSS controls including: Main steam line
radiation monitors.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
__
36. 05462 4.3 1 001/1/l!ALARMS MODSICIA
.~ 3.313.4/R/SRM3UI/~MAR/SDR .___
~-
j
r
I
1
The following Unit I conditions exist:
- The Reactor was operating at 78% power when a loss of the A Feedwater Pump
~ The Team is taking the required immediate actions in acordance with 1 -AP-21 .00,
- The Reactor Operator is driving rods in manual to lower Tavg
- Tavg is within 3 O F of Gref
- Annunciator 1G-G8, ROB BANK D LO LIMIT, has annunciated
occurred
Loss of Main Feedwater Flow
Which ONE of the following is the correct response to the given plant conditions?
A. Shutdown margin is not sufficient for the given plant conditions and operators
should emergency borate to regain the required shutdown margin.
BY The operator has driven rods in too far for the existing boron concenration and
should borate from the Boric Acid Tanks.
C. Shutdown margin is not sufficient for the given plant conditions and operators
should trip the Reactor and go to 1 -Ea, Reactor Trip or Safety Injection.
B. The turbine load has decreased too far and the operator should raise turbine load.
Surry Nuclear Plant 2084-301
DRAFT RO lnital Exam
References:
ND-89.3-bP-3, Main Feedwater System, Rev. 12
ND-95.1 -LP-4, Loss of Feedwater, Rev. 3
1 -AP-21 .OO, Loss of Main Feedwater Flow, Rev. 5
161-618, ROD BANK 83 LO LEMIT, Rev. 8
Distractor Analysis:
A. lncorrect because (1) not enough information is given to make the determination
that SDM is insufficient, and (2) even if SDM is not above that which is required,
emergency boration would not be the preferred method for regaining the required
SDM. This is clearly the wrong method for boration because xenon is building in
and only small borations would be desired to withdraw rods to clear the alarm.
alarm. Boration from the Boric Acid Tanks would be the correct mitigation strategy
and as such, is directed by the ARP. Operators would only borate the necessary
amount to clear the alarm.
designed to handle this magnitude of transient. Furthermore, the plant does not
need to be tripped with rods approaching or below insertion limits. Rod positions
just have to be restored to within limits.
D. Incorrect because turbine load should not be raised. Immediate actions have the
operators reduce turbine load to match steam flow and feed flow. Raising turbine
load under these conditions would not be the correct action. It would also be
nonconsemaive to add positive reactivity via the turbine during a transient condition
such as described in the stem.
B. Correct because rods being within 10 steps of its insertion limit would cause the
C. Incorrect because the initial power Bevel was less than 85% and the p h t is
854 Loss of Main Feedwater
G2.4.31: Knowledge of annunciators and indications and use OB response instructions.
Bank Question from 2003 Farley Exam (Farley WA was 054612220).
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
r 37.
__
055EKI.01 00ii1/118.4TTERYICIA
.-
3.3/3.7iB/SR03301/WMAB/SDK
._
___
The following plant conditions exist:
- A loss of all AC power has occurred.
- Operators have implemented ECA-0.0, boss of All AC Power.
~ Attempts to regain AC power have failed.
- Operators are performing ECA-0.0, Step 28, "Check DC Bus Loads"
Which ONE of the following should be performed to lower the Black Battery discharge
rate by the largest amount per ECA-O.O?
A. Secure Air Side Seal Oil Pump only.
B. Secure Air Side Seal Oil Pump and Emergency Turbine Lube Oil Pump.
6. Secure Air Side Seal Oil Backup Pump only.
DI Secure Air Side Seal Oil Backup Pump and Emergency Turbine Lube Oil Pump.
I
__
~
~
~.
~.
~
~
~
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
References:
ND-90.3-LP-6, 125 Vdc Distribution, Rev. 10
ECA-0.0, boss of All AC Power, Rev. 21
Distractor Analysis:
A. incorrect because the Air Side Seal Oil Pump is not a DC load, as is
the Air Side Seal Oil Backup Pump. Plausible because the candidate may not
know major Black Battery BC Loads, or may not know what actions are permitted
by ECA-0.0.
B. incorrect because the Air Side Seal Oil Pump is not a DC load, as is
the Air Side Seal Oil Backup Pump. Plausible because the candidate may not
know major Black Battery DC Loads, or may not know what actions are permitted
by ECA-0.0.
C. Encorrect ECA-0.0 will direct the securing of both Air Side Seal Oil Backup Pump
(ASSOBUP) and Emergency Turbine Lube Oil Pump, not just ASSOBUP.
Plausible because the applicant may not know that there is more than one pump to
secure to conserve Black Batteries.
$38. Correct because per ECA-0.0 step 28 and Basis for this step in ND-95.03-LP-17,
the purpose is to secure both pumps, which are large Black Battery DC loads, to
conserve the batteries (reducing battery discharge rate, thus prolonging battery life).
Surry ILT Bank Question #724
055 Station Blackout
EK1.01: Knowledge of the operational implications of the folbwing concepts as they
apply to the Station Blackout: Effect of battery discharge rate on capacity.
Surry Nuclear Plant 2004-301
DRAFT Fa0 lnital Exam
38.
___
0564.2 04 OOl/Z/I/C'ONDENSATE
~-
PUMP/C/A 2.612 RINISR04301~ABISDR
I
The following Unit 4 conditions exist:
- Two Main Feedwater Pumps are operating
- Reactor Power = 65%
- Condensate Pumps 1 -CN-P-I A and B are operating
- Condensate Pump 1 -CN-P-I C is Tagged Out of Service
- Condensate Pump 1-CN-P-1A trips and cannot be restarted
- Main Feedwater Pump Suction Pressure = 2 05 psig and slowly lowering
- Steam Generator Levels are slowly lowering
- 1 H-F8, FW PP SUCT HDR LO PRESS, is in alarm
Which ONE of the following is the correct operator action'?
A!
Enter 1-AP-21 .00, Loss of Main Feedwater Flow, and reduce turbine load Bo match
steam flow and feedwater flow.
I
B. Manually trip the Reactor and enter E-0, Reactor Trip or Safety Injection.
C. Secure one of the operating Main Feedwater Pumps and monitor the operating
Main Feedwater Pump Suction Pressure.
D. Enter 1 -AP-22 .OO, Loss of Main Feedwater Flow, and start a second HP Drain
PblITlp.
Surry Nuclear Plant 2084-301
DRAFT WO lnital Exam
Surry
References:
ND-89.3-LP-2, Main Condensate System, Rev. 16
ND-89.3-LP-3, Main Feedwater System, Rev. 12
1 -AP-21 .OO, Loss of Main Feedwater Flow, Rev. 5
ND-95.1-LP-4, LOSS of Feedwater, Rev. 3
1 H-F8, FW PP SUCT WDW LO PRESS, Rev. 0
1 HG8, FW PP DlSCH HBR LO PRESS, Rev. 8
1J-614, CN PPS DISGH HDR LO PRESS, Rev. 0
Distractor Analysis:
A. Correct because MFW Pump Low Suction Pressure and Discharge Pressure
Alarms are entry conditions into AP-21 .OO. Furthermore, with power at 65% the
direction is to reduce turbine load to match steam and feed flows. This will also
help to recover MWN Pump suction/discharge pressure.
B. incorrect because no trip criteria are met and AP-21 JXI directs power reduction.
C. Incorrect because tripping a MFW Pump will not alleviate the issue and there is no
procedural guidance to trip a fvlW Pump. Typically a MRlV Pump will be secured
at about 40% power.
D. Incorret because there is no guidance to start a second heater drain pump. The
correct response is to lower turbine load.
056 Condensate
A2.04: Ability to (a) predict the impacts of the following malfunctions or operations on
the Condensate System; and (b) based on those predictions, use procedures to
correct, control; or mitigate the consequences of those malfunctions or operations:
Loss of condensate pumps.
Sur9 Nuclear Plant 2004-301
DRAFT WO lnital Exam
39. ..
056AA1 26 001/i/I/DIBSEL
__
BKEAKER/<'/A 2.5/2..G~/SR0430I~AB/SDR
-
The following conditions exist:
~
A Loss of Off-Site Power has occurred
- #I Emergency Diesel Generator has started but failed to auto load
- It has been determined that the auto-closure circuit for 15H3, #1 EDG Output
- When the operator places the sync switch for 15H3 to "ON" he observes 120 volts on
Breaker, is inoperable and that 15H3 can be manually closed
the "incoming" meter, 0 volts on the "running" meter, and the synchroscope is
stationary at "3-o'clock"
Which ONE of the following actions is necessary prior to closing 15H3?
A. Raise EDG speed until the synchroscope is turning slowly in the fast direction, then
close S5H3 at "1 1 o'clock".
B. Momentarily press the "field flash" pushbutton, then sync and close 15H3.
e. Raise EDG voltage until the running metes indicates 128 volts, then sync and close
15H3.
D7 No additional action is necessary. Close 15H3.
Sur9
References:
ND-90.3-LP-I, Emergency Diesel Generator, Rev. 14
ND-90.3-LP-7, Station Service and Emergency Distribution Protection and Control,
Rev. 17
Distractor Analysis:
A. Incorrect because the bus is dead. Raising EDG speed will not synchronize the
phases.
B. incorrect because it will not be possible to synchronize (nor is it necessary because
the bus is dead). Also, field flash PB does not need to be pushed.
C. incorrect because raising the EDG voltage will not raise running voltage. lncoming
voltage is the EDG voltage (not running voltage).
B. Correct because the synchroscope has been turned on, there is no over-current or
differential and the aux trip relay does not need to be reset (ND-90.3-LP-7 pg. 18).
Therefore, all criteria for manually closing the breaker are met.
056 Loss of Off-Site Power
AAI 26: Ability to operate and / or monitor the following as they apply to the Loss of
Off-Site Power: Circuit Breakers
S u r ~
Nuclear Plant 2084-301
DRAFT RO lnital Exam
Which ONE of the following reasons correctly states why the reactor would be tripped
for a sustained loss of Vital Bus II?
A. Power to the Reactor Protection System is lost.
B. Pressurizer pressure control is lost.
C. Control of Steam Generator Feed Regulating Valve is lost.
DY "B" Reactor Coolant Pump must be stopped.
Scerrgc
R?BeEnC@S:
1-AP-10.02, boss of Vital Bus Il, Rev. 9
ND-90.3-LP-5, Vital and Semi-Vital Bus Distribution, Rev. 17
Distractor Analysis:
A. Incorrect because RPS is de-energize to trip. If due to other channel failures, de.,
the loss of VB Il will not preclude a trip if one is needed.
B. incorrect because Pzr P Controller will transfer to AUTO-HOLD, but MANUAL
control is still possible, thus precluding the need for rx trip.
C. Incorrect because FW-FCV-1488 Flow Controller will transfer to AUTO-HOLD, but
MANUAL control is still possible, thus precluding the need for rx trip.
D. Correct because Component Cooling is lost to the "B" WCP Lube Oil Cooler. RCP
Parameters will eventually exceed limits (1-AP-10.02 Att. I), requiring that the RCP
be secured following a manual rx trip.
059 boss of Vital A 6 Inst. Bus
AK3.01: Knowledge of the reasons for the following responses as they apply to the
boss of Vital A@ Instrument Bus: Actions contained in EOP for loss of vital ac electrical
bus.
Surry ILT Bank Question #223
Surry Nuclear Plant 2004-301
DRAFT RQ Inital Exam
41 . 058AA2.OI OOI/l/l/L,OSS OF DC POWIER/C/A 3.3/4.I/N/SR04301/R/MAR/S.I)K
The following Unit 1 csnditons exist:
- 1 K-87, BATT SYSTEM 1A TROUBLE, annunciates
- An operator reports that Battery Charger DC Output for UPS 1A-1 reads (4 amps
Which ONE of the following correctly describes the power supply to the associated DC
and Vital AC buses?
I K-A8, UPS SYSTEM TROUBLE, annunciates
A. DC Bus 1A-1 will be supplied by only Battery 1A as indicated by DC Bus voltage
slowly trending down over time and Vital AC Buses 1 and 1A will be supplied by
Bus 1H1-1.
B. DC Bus 1A-1 will be supplied by only Battery 1A as indicated by BC Bus voltage
slowly trending down over time and Vital AC Buses 1 and 1A will be supplied by
Bus 1 HI-2.
C. DC Bus 1A-1 will be supplied by UPS 1A-2 as indicated by DC Bus Voltage
remaining stable at 12% VBC and the Vital PIC Buses 1 and 1 A will be supplied by
D:' DC Bus 1A-1 will be supplied by UPS 1A-2 as indicated by DC Bus Voltage
remaining stable at 125 VDC and the Vital PIC Buses 1 and 1A will be supplied by
1 H1-2.
Surry Nuclear Plant 2004-301
DRAFT 80 Initai Exam
Surly
References:
ND-90.3-LP-5, Vital and Serni-Vital Bus Distribution, Rev. 11
NB-90.3-LP-6, 125 VDC Distribution, Rev. 10
1 K-87, BATT SYSTEM 1 A TROUBLE, Rev. 5
1 K-A8, UPS SYSTEM TROUBLE, R ~ v .
1
1 1448-FE-1 G,
Sheet 1 of 1, 125V DC One Line Diagram - Surly Power Station Unit 1,
Rev. 33
Distractor Analysis:
A. Incorrect because the battery should not be supplying the DC Bus alone. The DC
Bus is being supplied by the other UPS from 1 HI-2. Also, vital AC Buses 1 and 1A
are being supplied by Bus 1 HI -2, which is the alternate AC source.
B. Incorrect because the battery should not be supplying the DC Bus alone. The DC
Bus is being supplied by the other UPS from 1 H1-2.
C. Incorrect because the Vital AC Buses 1 and 1A are being supplied by Bus 1 HI-2,
which is the alternate AC source.
D. Correct because the sther UPS will still be supplying DC Bus 1A-1 and the Alternate
AC Source 1 H1-2 will supply Vital PIC Buses t and 1A.
058 Loss of DC Power
AA2.01: Ability to determine and interpret the following as they apply to the loss of DC
Power: That a loss sf DC Power has occurred; verification that substitute power
sources have come on line.
Surv Nuclear Plant 2004-301
DRAFT RQ lnital Exam
- - 1
42. 059A1.03 001/2/1/MA1IN FEEDWATEEUMEM 2.7/2.9/N/SK0430 I/R~MM/SDR
Which ONE of the following set of practices should be observed by operators for
starting the second Main Feedwater Pump per GO$-1.5 (Unit Startup, 2% Reactor
Power to Max Allowable Power) and OP-FW-804 (Main Feedwater System Operation)?
A. The second Main Feedwater Pump should be started prior to exceeding 50% power
to preclude problems with main feedwater flow capability. Following pump stark. if
the Main Feedwater Pump Reciculation Valve is in AUTO, the operator should
observe that valve closure will occur as the feed flow rises above 3008 gpm.
5. The second Main Feedwater Pump should be started between 50% power and 65%
power to preclude problems with main feedwater flow capability. Following pump
startB,
if the Main Feedwater Pump Recirculation Valve is in AUTO, the operator
should observe that valve closure will occur as the feed flow rises above 3286 gpm.
CY The second Main Feedwater Pump should be started prior to exceeding 50% power
to preclude problems with main feedwater Blow capability. Operating the second
Main Feedwater Pump on recirculation with the discharge MOV closed should be
minimized to prevent overpressurization of the piping between the discharge check
valve and the MOV as the system heats.
D. The second Main Feedwater Pump should be started between 50% power and 65%
power to preclude problems with main feedwater flow capability. Operating the
second Main Feedwater Pump on recirculation with the discharge MQV closed
should be minimized to prevent overpressurization of the piping between the
discharge check valve and the MOV as the system heats.
Susry Nuclear Plant 2004-301
DRAFT RO Bnital Exam
Serrry
References:
1 -GBP-l.5, Unit Stal-eup, 2% Reactor Power to Max Allowable Power, Rev. 32
1 -0P-FW-004, Main Feedwater System Operation, Rev. 8
ND-89.3-LP-3, Main Feedwater System, Rev. 12
Distractor Analysis:
A. Incorrect because recirc should modulate closed at 4800 gpm.
B. Incorrect because reeirc should modulate closed at 4808 gpm.
C. Correct because of NOTE on Pg. 34 of 44 of GOP-I .5 and CAUTION on Pg 12 of
D. Incorrect because second feedwater pump should be stafled prior to 50% power.
34 Of OP-FW-004.
059 Main Feedwater
A1.03 Ability to predict and / or monitor changes in parameters (to prevent exceeding
design limits) associated with operating the MFW controls including: Power level
restrictions for operation of MFW pumps and valves.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
43. 059AAl 01 001/1/2lLIQIJID RAD RELbASE/C/A 3 5/3.5/MISR()iC30i/A~/§~~
_ _
-
The following Unit 1 conditions exists:
- A Large Break Loss of Coolant Accident has occurred
- The "B" Brain of Recirc Spray (RS), the only available train, is in sewice
- 4-RM-G7, DlSCH TNL ALERT / FAILURE, annunciates
~
1-RM-88, RS/SW HX B ALERTFAILURE, annunciates
- Reactor Operator notes the RSISW HX B Monitor is trending up, but the Discharge
Tunnel Wad Monitor is indicating all EEEEEs with Wed and Yellow Lights kit and
Green Light out.
Which ONE of the following is the correct operator response?
A. Ensure 870 additional releases are in progress and secure RS.
BY Ensure no additional releases are in progress, and increase radiation monitoring.
C. Verity all automatic actions have occurred and reset the Discharge Tunnel Digital
Rate Meter and perform a source check.
D. Verify all automatic actions have occurred and raise the Discharge Tunnel Monitor
set point.
Surry Nuclear Plant 2004-301
DRAFT 80 lnital Exam
Sur9
Wefe re nces :
ND-93.5-LP-1, Pre-TMI Radiation Monitoring System, Rev. 8
1-RM-G7, DlSCH TNL ALERT / F A " E , Rev. 4
1-RM-A8, RS/SW HX B AbERT/FAlbURE, Rev. 3
Distractor Analysis:
A. Incorrect because the last available RS train should not be secured, as stated in
RM-G7 and RM-A8 Caution Statements. Plausible because this is the correct
course of action if the other train was available.
B. Correct because the last train of RS should not be secured. Other rad monitors
should be checked to see if blowdowns have been diverted, to verify that there is no
CCW/SW HX leak, and lo verify that no CP 51d Liquid releases are occurring.
Additional monitoring is called for by the ARPs due to the fact that the last train of
RS should not be secured.
C. Incorrect because there are no automatic actions to verify. Plausible because the
applicant may not know that there are no auto actions associated with these
particular monitors. With a failed monitor, ARPs will direct a reset and source
check, which adds to the plausibility.
B. Incorrect because there are no automatic actions to verify. Plausible because the
applicant may not know that these are not auto actions associated with these
palaicular monitors and it is not uncommon for an alarm setpoint to be raised to
alert operators of worsening conditions. The Discharge Tunnel Monitor has the
indications of being failed, therefore adjusting the setpoint is not a success path.
059 Accidental Liquid Radwaste Release
AAI .61: Ability to operate and / or monitor the following as they apply to the Accidental
Liquid Radwaste Releases: Wadioactive-liquid monitor
Modified Surry ILf Bank Question #I977
Surry Nuclear Plant 2004-301
DRAFT BO Initat Exam
44. 06 1.4 1.04 00 1/21 1 /hFw CONDENSATEIMEM 3.9/3.9/N/SR0430 lIRIMAI3ISDK
1
~-
1-CN-TK-1, Emergency Condensate Storage Tank (ECST)> is supplying AFW Pumps
for Residual Heat Removal via Steam Generators. 1J-F4, CST 1 10,000 GAL LO LVL,
has annunciated. ECST level is 90% and lowering.
Which ONE of the following is correct regarding refilling of the ECST?
A. Filling shall commence prior to the ECST level reaching 54%. AFW pumps must be
secured prior to commencing the fill.
B. Filling may commence after the ECST level drops below 60,000 gallons as long as
!
I :
refill begins within two hours of securing the AFW pumps.
C. AFW Pumps must be secured prior to commencing the fill and the ECST must be
filled within two hours.
D I Filling of the ECST shall commence prior to the ECST level reaching 54%. AFW
pumps may continue to operate during the refill.
Surry
References:
ND-89.3-LP-4, Auxiliary Feedwater System, Rev. 19
1 J-F4, CST 19 0,000 GAL LO LVL, Rev. 3
Tech Spec 3.6-1, Amendment No. 224 and 220
Distractor Analysis:
A. Incorrect because AFW pumps may continue to run during refill based on ARP
B. Incorrect because volume must remain above 60,QOO gal (54%).
C. Incorrect because AFW pumps do not need to be secured for refill.
D. Correct based on all three of the above references.
1 J-F4 r\\lQt@.
A1.04: Ability to predict and / or monitor changes in parameters (to prevent exceeding
design limits) associated with operating the AFW controls including: AFW source tank
lev@/.
Surry Nuclear Plant 2004-301
DRAFT RO tnital Exam
Bf a spent fuel assembly is damaged by being dropped in the spent fuel pool, which
ONE of the following pairs of radiation monitors would indicate an increase in radiation
level?
A. Spent Fuel Pit Bridge Crane Radiation Monitor and Auxiliary Building Control
Victoreen Area Radiation Monitor
B. Ventilation Vent Particulate Radiation Monitor and Auxiliary 5uilding Control
Victoreen Area Radiation Monitor
Cl' Spent Fuel Pit Bridge Crane RadadiEitioR Monitor and Ventilation Vent Gaseous
Radiation Monitor
D. Ventilation Vent Gaseous Radiation Monitor and the Liquid Waste Effluent Process
Monitor
Surry (Utility needs to add correct RM equipment numbers.)
References:
ND-93.5-LP-1, Pre-TMI Radiation Monitoring System, Rev. 8
Q-AP-22.00, Fuel Handling Abnormal Conditions, Rev. 18
Q-RM-D3, 1 -RM-RI-153 HIGH, Rev. 4
O-WM-B4, 1 -RM-RI-I 52 HIGH, Rev 8
Distractor Analysis: (maybe get some help to provide a little better distractor analysis?)
A. Incorrect because the Aux Bld Control Victoreen Area Radiation Monitor would not
show an increased indication.
B. Incorrect because the Aux Bld Control Victsreen Area Radiation Monitor would not
show an increased indication.
C. Correct because both monitors would show an increased indication.
D. Incorrect because a liquid waste process effluent monitor would not see the results
of the failed fuel.
061 ARM System Alarms
AA2.01: Ability to determine and interpret the following as they apply to the Area
Radiation Monitoring (ARM) System Alarms: ARM panel displays.
Surry Requal Bank Question #118
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
46.
062.41.01 001/1/2/EDG
._
DIESEMEM 3.43 8(N/SR043011R/MBU/SDR
~
The following conditions were noted during the performance of 1 -OPT-EG-001,
Number 1 Emergency Diesel Generator Monthly Start Exercise Test:
- The EDG was loaded at a rate of 550 KMIIMIN
~ The Maximum load attained was 2650 KW
- The Maximum KVAR was 500 WAR out
~ The output voltage was stable at 4300 VAC
Which ONE of the following was in violation of the EDG Precautions and Limitations
per 1 -8PT-EG-001?
A!
Load Rate
B. Maximum Load
C. Maximum W A R out
D. Output voltage
References:
1 -OPT-EG-004, Number 1 Emergency Diesel Generator Monthly Start Exercise Test,
Rev. 24
1 -0P-EG-001, Number 1 Emergency Diesel Generator, Rev. 17
Distractor Analysis:
A. Correct because the ioading rate should not exceed 500 KW/MIN during normal
operations.
El. Incorrect because max load rating is 2950 KW.
C. Incorrect because max KVAR out is 500 WAR.
D. Incorrect because output voltage should be maintained between 4000 and 4400
VAC.
862 AC Electrical Distribution
A1 .Ol : Ability to predict and / or monitor changes in parameters (to prevent exceeding
design limits) associated with operating the ac distribution system controls including:
Significant BIG load limits.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
47. 062.4.41.06 Q0L/I/l/SERVICX
~-
WATEWMEM 2.9/2.9/BISR(d4301/M~/S~~
~.
The following Unit I conditions exist:
- Power = 100%
- During testing, an Intake Canal how bevel lsolation Signal is inadvertently actuated
Which ONE of the following correctly states the plant response caused by the Low
Level Isolation Signal?
A. 1-SW-MOV-102A and B (CCHX and SW-P-4 Supply) will close and can only be
reopened after 5 minutes.
B. I-SW-MOV-lQ2A and B (CCHX and SW-P-4 Supply) will go to 25% open and can
C:' 1 -SW-MOV-l02A and B (CCHX and SW-P-4 Supply) will close and can be
be fully opened after 5 minutes.
reopened when the low Bevel signal is reset.
D. 1 -SW-MBV-l02A and B (CCHX and SW-P-4 Supply) will go 25% open and can be
fully opened when the low level signal is reset.
Surv (Utility needs to verify technical accuracy and provide any additional reference
material (electrical print?)).
References:
ND-89.5-LP-2, Service Water System, Rev. 20
Distractor Analysis:
A. Incorrect because the valves will close, but cannot be re-opened until Canal Low
Level Isolation Signal is cleared. If the valves would have been closed due to a
CLS, then they could have been re-opened after 5 minutes even without the CLS
cleared.
E3. Incorrect because the valves will go fully closed.
C. Correct because the valves wili close, but cannot be re-opened until Canal bow
Level Isolation Signal is cleared. If the valves would have been closed due to a
CLS, then they could be opened after five minutes without resetting CLS.
3. Incorrect because, as states above, the valves will close.
062 Loss of Nuclear Svc Water
AAl.06: Ability to operate and / or monitor the following as they apply to the Loss of
Nuclear Service Water (SWS): Control of flow rates to components cooled by the
SWS.
Surry Nuclear Plant 2004-381
DRAFT Fa0 lnital Exam
_.
48. 063A4.01 001/2/1/BREAKERS/C/A
- .
2.W. l/N/SR04301/R/M.4B/SI)R
~.
_____
Unit 1 was operating at 68% power when the following plant conditions developed:
- 1 K-A7, BATT SYSTEM 1A TROUBLE, alarm annunciates
- "A" SG PORM Indicating Lights are not lit
- MSTV Indicating Lights are not lit
- PORV 1455C/1456 Indicating Lights are not lit
- "A", "D", and "H"
Breaker Indicating Lights are not lit
~ There is no indicated letdown flow
- The Turbine Driven AFW Pump is running
Which ONE of the following describes the plant conditions assuming no other failures
in addition to the cause of the above conditions?
A:' The reactor will automatically trip. The turbine wit6 automatically trip when the
reactor is manually tripped.
B. The turbine will automatically trip. The reactor will automatically trig due to the
automatic turbine trip.
C. The reactor must be manually tripped. The turbine must also be manually tripped.
B. The reactor will automatically trip. The turbine will not automatically trip and must
be manually tripped.
References:
NB-90.3-LP-6, 125 Vdc Distribution, Rev. 10
Distractor Analysis:
A. Correct because the reaetos will automatically trip on loss of voltage to the "A" RTB
UV coil to a loss of the "A" BC Bus (see ND-90.3-LP-6). The turbine will not trip
until the reactor is manually tripped in accordance with E O .
B. Incorrect because the reactor will automatically trip due to loss of voltage to the "AIh
RTB UV coil due to the loss OB the "A" de Bus.
C. Incorrect bemuse the reactor does not need to be manually tripped to trip the
reactor and the turbine will automatically trip when the reactor is tripped per E-0.
D. Incorrect because the turbine does not need lo be manually tripped. The turbine
will trip when the reactor is manually tripped in E-0 or when the other train of RPS
occurs due to low SG levels.
(363 DC Electrical Distribution
A4.01: Ability to manually operate and / or monitor in the control room: Major breakers
and control power fuses.
Surry Nuclear Plant 2004-301
DRAFT WO lnital Exam
-
49. 064K2
__ 01 001/2/1/DCS AIR COh4PRESSOWC'iA 2 7/3.1/N/SR01301~ARISDK
_ _ _ _ -.
The following plant conditions exist:
- Bus 1 J1 voltage drops to 407 volts and returns to 488 volts seven seconds later and
~
Bus 2J1-1 voltage is 441 volts and stable
remains stable
Which ONE of the following correctly states the source of power for Diesel Generator
- 3's Air Csmpaessors?
A. Bus 1J1 remained the power supply throughout the seven second voltage drop.
B. Six seconds after the voltage dropped on Bus l J 1 ~
Bus 2J1-1 became the power
supply. Bus 2J1-1 will remain the power supply until manually transferred back to
Bus 1J1
C!' Six seconds after the voltage dropped on Bus 1J1~
Bus 2J1-1 became the power
supply. Bus 2J1-1 will remain the power supply for 38 minutes with Bus 1J1 greater
than 440 volts, at which time it will automatically return to Bus 1 J1.
D. Six seconds after the voltage dropped on Bus 1J1, Bus 2J1-1 became the power
supply^ Bus 2J1-1 will remain the power supply for six seconds with Bus 1J1
greater than 4410 volts, at which time it will automatically return to Bus 1 J1.
Surry Nuclear Plant 2004-381
DRAFT 88 lnital Exam
References:
ND-98.3-LP-1, Emergency Diesel Generator, Rev. 14
P&lD 11448-FE-IAA, Appendix R Evaluation Electrical One kine Biagram Surry Power
P&DD 1 1448-FE-1
P1,480V One Line Diagram MCC 1 J1-1 A Surry Power Station Unit 4 ,
Station Unit 1, Rev. 23
Rev. 4
Distractor Analysis:
A. Incorrect because 1 J1 voltage was less than 410v for greater than 6 seconds.
Therefore, 2J1-1 became the power supply after 6 seconds. The AET will check for
2J1-1 voltage greater than 440v prior to swapping to the alternate power supply.
normal-seeking ABT. Therefore, at the beginning of this sequence, the power
supply would have been 141.
Therefore, 2J1-1 became the power supply after six seconds. The ABT will check
for 2J1-1 voltage greater than 448v prior to swapping to the alternate power supply.
When the normal power supply voltage is restored to > 440v, a 30 minute time delay
is started. If the voltage remains above 440v for 30 minutes, then it transfers back
to the normal power supply (1 Jl).
B. Incorrect because this is the alternate power supply and the ABT is a
C. Correct because 1J1 voltage was less than 41 0v for greater than 6 seconds.
B. Incorrect because of the 30 minute time dehy mentioned above.
064 Emergency Diesel Generator
K2.01: Knowledge of bus power supplies to the following: Air Csmpessors.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
~ 50. 065AA2 .
-
01 001/1/1/AIK
IA RHIPUCIA 2.9/3.2/U/SK04301~MARISL)R
~-
-
The following plant conditions exist:
- Unit 2 is in intermediate shutdown
- Operators are attempting to warm the RHR system
- An instrument air leak has developed, but the location is yet to be determined
~ An Operator reports the sound of compressed air leaking in the area of the RHR
pump platform.
1 B-E6, lA LOW HBR PWESS/IA CBMPR 1 TRBL, has annunciated
- instrument air pressure is approximately stable at 60 psig
Which QNE of the following correctly explains the potential effect on warming the RHR
system?
A. If the ais leak is a rupture upstream of the isolation valve for the air supply to
HCV-1758 (WHR Heat Exchanger Outlet Valve), the valve will fail closed. The line
may be crimped if the leak will not affect vital control instruments. Operators should
use the portable air bottle, via quick disconnect, to operate the valve.
B. If the air leak is a rupture upstream of the isolation valve for the air supply to
HCV-1758 (RHR Heat Exchanger Outlet Valve), the valve will fail open. The tine
may be crimped if the leak will not affect vital control instruments. Operators should
use the portable air bottle, via quick disconnect, to operate the valve.
C:' If the air leak is a rupture upstream of the isolation valve for the air supply to
HCV-I 742 (CVCS Flow Regulator Control Valve), the valve will fail closed. The line
may be crimped if the leak will not affect vital control instruments.
D. If the air leak is a rupture upstream of the isolation valve for the air supply to
HCV-1142 (CVCS Flow Regulator Controi Valve), the valve will fail open. The line
may be crimped if the leak will not affect vital control instruments.
Surry Nuclear Plant 2004-301
DRAFT WO lnital Exam
Surry
References:
NB-88.2-LP-1, Residual Heat Removal System Description, Rev. 8 (Pages 9, 10, 11)
ND-88.2-LP-2, Operation of Residual Heat Removal System, Rev 15
P&IB 11448-FM-087A Sh 2 of 2, Residual Heat Removal System, Rev. 26
P&iD 11448-FM-075E Sh 1 of 2, Compressed Air System, Rev. 43
1 B-E6, IA LOW HDR PRESSAA COMPR 1 TRBL, Rev. 9
Distractor Analysis:
A. Incorrect because HCV-1758 fails open and cannot be operated with a portable air
bottle. PIausible because the applicant may get wnsfused on which valve in this
flowpath has the portable air bottle feature.
B. Incorrect because HCV-1758 cannot be operated with a portable air bottle.
Plausible because the applicant may get consfused on which valve in this
flowpath has the portable air bottle feature.
C. Correct because HCV-1142 is fail closed and this is the flow path for system
warmup. ARP states that leaks may be stopped via crimping if the leak will not
affect vital instrumentation.
B. Incorrect because HCV-1142 fails closed. Plausible because the applicant may get
confused on failure modes of HCV-1142, especially since it does have a backup air
bottle feature for App. R purposes.
065 Loss of Instrument Air
AA2.01: Ability to determine and interpret the folbwing as they apply to the loss of
instrument air: Cause and effect of low pressure instrument air alarm.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
I
51 . 067G2.4 I8 __
001/1/21fiTRE RWST CCMEM 2.713 6/B/SR04301/R/h4AR/SDR
. ___
In FCA-8.00, Limiting Auxiliary Building Fire, if Charging Pump CC Pumps are not
running, the operator is directed to shift charging pump suction to the RWST. Which
ONE of the following describes the basis for this step?
A. Suction is shifted to the RWST to maximize boron injection before the charging
pumps overheat and are lost due to a time-overcurrent breaker trip.
B. Suction is shifted to the RWST to maximize boron injection before the charging
pumps overheat and are lost due to a ins8antaneous-overcurrent breaker trip.
C. The loss of Charging Pump CC will eventually result in a loss of VCT level due to a
loss of makeup; therefore suction is shifted to the RWST.
DI' The RWST supplies cooler water to the Charging Pumps; thereby minimizing the
cooling requirements for the Charging Pumps.
Surry (Utility needs to verify technical acuracy and supply additional supporting material
if any is availble.)
Wefernces:
ND-95.6-LP-3, Safe Shutdown Fire FCAs, Rev. 5
0-FCA-8.00, Limiting Auxiliary Building Fire, Rev. 13
Distractor Analysis:
A. Incorrect because the concern is with overheating the pump, not maximizing boron
injection prior to the pump overheating. Supplying cooler RWST water will reduce
the pump temperatures.
B. lncsrrect because the concern is with overheating the pump, not maximizing boron
injection prior to the pump overheating. Supplying cooler RWST water will reduce
the pump temperatures.
C. Incorrect because VCT level will not be reduced as a result of no CC.
D. Correct because cooler RWST water will help reduce pump temps when CC is lost.
067 Plant Fire Bn-Site
62.4.18: Knowledge of specific bases for EOPs.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
The following Conditions exist:
- Both Units are at 100% Power
- Unit 1 Operators have discovered indication of a small tube leak in the "A" Steam
Generator for their Unit
- Spent Fuel is being moved in the Spent Fuel Storage Pool to facilitate rack
inspections
- O-RM-M4, f-VG-R~-1634 HIGH, alarms
- Ali Radiation Monitors appear to be operating satisfactorily
- Ventilation and Radiation Monitors are in their normal alignment
Which ONE of the following could cause RM-VG-I 04 (#I Vent Stack WMp to detect
higher than normal activity'?
A. A Steam Generator Tube Leak on Unit 1
BY A spill of high activity coolant in the Chemistry Hot Lab.
6. A spill of high actiwity coolant in the High Rad Sample System Room.
B. A drQpped fuel assembly in the fuel building.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
Surry
References:
Q-RM-M4, 1-VG-RI-104 HIGH, Rev. 2
8-AP-22.00, Fuel Handling Abnormal Conditions, Rev. 18
ND-95.3-LP-1, Pre-TMI Radiation Monitoring System, Rev. %
Distractor Analysis:
A. Incorrect because the normal configuration for the ventilation system would not
have Main Condenser Air Ejector aligned to discharge Bo the Number 1 Vent Stack
upstream of Radiation Monitor I-VG-RM-I 04.
B. Correct because 0-RM-M4 alarming could be caused by a coolant spill in the Chem
Hot Lab according to the ARP.
C. Incorrect a spill in the High Radiation Sample System Room would not cause this
alarm according to the ARP.
D. Incorrect because fuel clad damage would not be detected by RM-VG-104 when in
its normal configuration. 0-AP-22.00 does not list RM-VG-104 as a potential means
of indication for damaged fuel clad.
068 Liquid Radwaste
M4.81: Knowledge of design Beature(s) and / or interlock(s) which provide for the
following: Safety and environmental precautions for handling hot, acidic, and
radioactive liquids.
Surry Wequal Exam Bank Question #462 (ID:AR$Q076)
Surry Nuclear Plant 2004-301
DRAFT 80 lnital Exam
53. 071K4 06
__ OOII2I2IWASTE GAS ._
GASEOUSMEM 2 7/3 5/N/SKO4301/WMAB/SDR
A discharge of a waste gas decay tank is in progress when WM-GW-I 84 reaches the
high alarm setpoint and alarm 0-f%M-K3, 1 -GW-RI-I01 HIGH, annunciates. Which
ONE of the following is N8T an automatic action initiated by the high radiation levels
from the waste gas decay tank release?
'
A. 1 -GW-FGV-lOI I Decay Tank Bleed Isolation Valve, closes.
B. 1 -GW-FCV-160, CTMT Vacuum Pump Discharge Isolation Valve closes.
C. 1 -GW-FCV-260, CTMT Vacuum Pump Discharge Isolation Valve, doses.
D!' Associated vacuum pumps trip.
Surry (Utility needs to verify technical accuracy)
._
-
~
._
-
References:
ND-92.4-LP-1, Gaseous and Liquid Waste Processing Systems: Rev. 8
ND-93.5-LP-I, Pre-TMI Radiation Monitoring System, Rev. 8
Q-RM-W, I-GW-Rl-101 HIGH, Rev. 0
Distractor Analysis:
A. Incorrect because according to ARP, this valve will close ora reaching the high alarm
B. incorrect because according to ARP, this valve will close on reaching the high alarm
C. incorrect because acording to ARP, this valve will close on reaching the high alarm
D. Correct because the pumps must be manually secured if GW-166) or GW-260 are
setpoint.
setpoint.
setpoint.
closed. This info is in a CAUTION in the ARP and a step is provided in the ARP to
secure the pumps foilswing the closure of GW-160 / 260.
071 Gaseous and Liquid Waste Processing Systems
K4.86: Knowledge of design($) features and / or interlocks which provide for the
following: Sampling and monitoring of waste gas release tanks.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
54.
~-
073G2.1.23 001/2/l/PROCESS RADIATION//C/A 3.9/3.0/N/SR04301/Kl~~~/SDR
Which ONE of the following is sufficient conclusive indication to warrant a correct entry
into AP-I 6 . 0 , Excessive RCS Leakage?
A. Rising containment humidity, rising containment temperature, and rising
containment pressure.
B." Rising steam generator water level, rising charging flow, and rising Condenser Air
Ejector Radiation Monitor reading.
C. Rising Condenser Air Ejector Radiation Monitor reading, rising steam generator
blowdown radiation monitor reading, and stable containment pressure.
D. Wising containment sump level, lowering pressurizer pressure, and rising
containment pressure.
I
Surry
References:
1 -AP-I 6.00, Excessive RCS Leakage, Rev. 1 1
1 -AP=24.00, Minor SG Tube Leak, Rev. 8
1 -E-Q, Reactor Trip or Safety Injection, Rev. 46
ND-93.5-LP-1, Pre-TMI Radiation Monitoring System, Rev. 8
Distractor Analysis:
A. incorrect because a steam line break can cause Containment humidity, temperature,
and pressure to rise. Distractor is plausible because these are all possible for an
WCS leak.
steadfeed mismatch. The charging Blow and Air Ejector Rad monitor corroborates
that the problem is tube leakage.
C. incorrect because these parameters are indications that there may be a tube
leak; however, these same indications may present themselves with a fuel failure or
crud burst. Distractor is plausible because these parameters may indicate as
stated if RCS leakage actually exists. Distractor is incorrect because these
parameter trends may be caused by increased RCS activity.
steam leasdbreak. Distractor is plausible because these parameters may actually
change as indicated during an RCS leak.
B. Correct because SG water level is indication that there may be a tube leak or
D. Incorrect because the combination of these parameters may be caused by a
073 Process Radiation Monitoring
G2.1.23: Ability to perform specific system and integrated plant procedures during all
modes sf plant operation.
Surry Nuclear Plant 2004-301
DRAFT RO M a l Exam
55. 076AK2 01 00111/2/RCS
~
ACTEVITYICIA 2.6/3.OW/SR0430IIRIMN1ISDR
-~
Hydrogen peroxide has just been added to Unit 2 RCS resulting in an increase in the
primary coolant activity. The first indication that the activity level has increased will be
seen on the
1
and the team should
A. Containment particulate radiation monitor; increase Blow through the letdown cation
bed.
B: Letdown radiation monitor; monitor letdown filter differential pressure.
C. Letdown radiation monitor; monitor seal return filter differential pressure.
D. Containment particulate radiation monitor; decrease flow through the letdown cation
bed.
References:
ND-93.05-LP-1, Pre-TMI Radiation Monitoring System
ND-88.3-LP-3, Seal Injection, Rev. 6
Bistractor Analysis:
A. Incorrect because containment particulate radiation monitor would not change
significantly.
B. Correct because letdown radiation monitors would indicate quickly due to hydrogen
peroxide increasing reactor coolant activity and letdown filter dP would also rise.
6. incorrect because the hydrogen peroxide should not affect the seal return dP, at
least not as readily or as soon as the letdown filter dP. There is 8 gal of CVCS
water that goes to each RCP for seal injection. Five of these gallons flows down
the shaft past the thermal barrier and ends up in the RCS. The other three gallons
eventually passes through the seal return filter. The CVCS water that enters the
RCP seal area has already been filtered prior to getting to the RCP seals. This
prefiltering is designed to protect the seals. The water coming from the
RCP seal area should be relatively clean CVCS water, not WCS water; therefore
making the seal return filter a relatively poor indicator of a crud burst.
significantly.
D. lncorrect because containment particulate radiation monitor would not change
Surry Bank lbT Exam Question #1606
076 High Reactor Coolant
AK2.01: Knowledge of the interrelations between the High Reactor Coolant Activity
and the following: Process radiation monitors.
Surry Nuclear Plant 2004-381
DRAFT RO lnital Exam
I-
I
The following Unit 1 conditions exist:
- A Large Break LQCA occurred 45 minutes ago
- Recirculation Spray is operating
~ MCC 1 H1-2 de-energizes
Which ONE of the following correctly describes the impact on Service Water to and
from the Recirc Spray Heat Exchangers?
A:' Recirc Spray Heat Exchanger 1 -RS-E-1 A Service Water Inlet (MOV-SW-
Outlet (MBV-SW-I 858) Valves de-energize.
B. Recirc Spray Heat Exchanger 1 -RS-E-1 B Service Water Inlet (MOV-SW-
Outlet (MOV-SW-105B) Valves de-energize.
0414) and
04B) and
C. Weeirc Spray Heat Exchanger Service Water Inlet (MOV-SW-I 03A) and Recirc
Spray Heat Exchanger 1 -RS-E-1A Sewice Water Inlet (MQV-SW-lQ4A) Valves
de-energize.
D. Weeirc Spray Heat Exchanger Service Water Inlet (MOV-SW-I 038) and Recirc
Spray Heat Exchanger 1 -RS-E-1 B Setvice Water lnlet (MOV-SW-lQ4B) Valves
de-energize.
References:
ND-91 -hP-6, Recirculation Spray System, Rev. 9
ND-89.5-LP-2, Service Water System, Rev. 20
P&ID 1 1448-FE-1 M, Sh 1 of 1
I 48OV One Line Diagram Surry Power Station - Unit 1
I
P&lD 11448-FE-1 L, Sh 1 of 1,480V One Line Diagram Surt'y Power Station - Unit 1
Rev. 59
Rev. 52
Distractor Analysis:
A. Correct because MBV-SW-1 04A and 1054 are both powered from 1 H1-2.
B. Incorrect because MOV-SW-IWB and 1058 are both powered from 1J1-2.
C. incorrect because MOV-SW-183A is powered from 1Hl-I.
D. incorrect because MOV-SW-IQ3B is powered from 1 J1-1 and MOV-SW-1845 is
powered from 1 J1-2.
096 Sewice Water
K2.04: Knowledge of bus power supplies to the following: Reactor building closed
cooling water.
Surry Nuclear Plant 2004-301
DRAFT 80 lnital Exam
57. 078A4.O 1 00 1/2/1/INSgWIJRIIPNTAIRICIA 3.113.1BISR0430 lm-R
1
~-
..
Unit 1 is at 50% power and the team is experiencing problems controlling feedwater
flow. An instrument Air Low Pressure Alarm is received in the Control Room. While
monitoring Instrument Air pressure, the 80 notes pressure is 50 psig and slowly
lowering.
Which ONE of the following actions should be taken?
r
A. Commence a slow power reduction to Hot Shutdown.
B. Commence a fast power reduction to Cold Shutdown.
C:' Trip the Reactor and go to 1 -E-), Reactor Trip or Safety Injection.
D. Isolate Service Air from Instrument Air and start the Sullair Diesel.
References:
ND-92.1 -LP-1, Station Air Systems, Rev. 13
0-AP-40.00, Non-recoverable Loss of Instrument Air, Rev. 17
1 B-E6, IA LOW HDR PRESS / 18 COMPR 1 TRBL, Rev. 9
Distractor Analysis:
A. Incorrect because 1 B-E6 and AP-40.00 directs rx trip, not power reduction.
B. Incorrect because 1 B-E6 and AP-40.00 directs IX trip, not power reduction. (Initial
distractor from exam bank was changed because it may have been a second
correct answer).
C. Correct because this is the guidance provided by t B-E6 and AQ-40.00.
D. Incorrect because 1 B E 6 and AP-40.80 directs rx trip, not power reduction when
pressure reaches 50 psig.
078 Instrument Air
84.01 : Ability to manually operate and / or monitor in the control room: Pressure
Surry Wequal Exam Bank Question 428
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
INSTR
~
With ALL air systems aligned in the automatic mode, which ONE of the following
describes the operation of the Station Instrument Air (IA) System for Unit I ?
(Assume ne, operator action is taken.)
A. Instrument Air is normally supplied by the Service Air System and the system is
backed up by IA when IA pressure reaches 95 pig.
B. Instrument Air is normally supplied by IA Compressors and the system is manually
backed up by the Sullair Diesel.
the IA System when IA pressure reaches 90 psig.
D. Instrument Air is normally supplied by the Service Air System and is backed up by
the Condensate Polishing Instrument Ais System when IA pressure reaches 98
psig.
CY Instrument Air is normally supplied by the Service Air System and is backed up by
~.
Surty
WeBe rences
ND-92.1-LP-1, Station Air Systems, Rev. 13
Distractor Analysis:
A. Incorrect because pressure must drop below 98 psig for IA to backup Service Air.
B. Incorrect because the IA System is nsrrnalty supplied by Service Air.
C. Correct because Service Air is the normal supply and IA is the backup when
D. Incorrect because IA is not backed up by the Condensate Polishing Instrument Air
pressure drops below 90 psig.
System when pressure drops to 98 psig. It is backed up by the IA System when
pressure drops below 90 psig.
078 Instrument Air
K4.02: Knowledge of the IAS design Beature(s) and or interlock@) which provide for the
following: Cross-over to other air systems.
Surry Requal Bank Question #512
Surry Nuclear Plant 2084-301
DRAFT RO lnital Exam
__ 59. 103A4.04 001/2/I/CLS COWTAINMENTICIA
- ._ 3.513 S/N/SR04301IRIMABISDW
_ _
The following Unit I conditions exists:
- A steam line rupture in Containment occurred several minutes ago
- Maximum Containment Pressure reached 24 psia
- Containment Pressure Transmitters now read:
- PT-LM-1 OOA = 17.7 psia
- PT-LM-1 OOB = 17.8 psia
.. PP-LM-1 00C = 17.6 psia
- PT-bM-100D = 17.9 psia
Which ONE of the following correctly describes resetting of Consequence Limiting
Safeguards (CLS) given the above conditions?
A. The CLS TRAIN A@) RESET PERMlSSlVE annunciator is lit. CLS HI and CLS
Hl-HI may be reset at this time. Upon reset, the multiplying relays will energize.
3:'
Neither CLS HI or CLS HI-HI may be reset at this time. The multiplying relays are
de-energized.
C. The CLS HI-HI RESET PERMISSIVE annunciator is lit. CtS HI-HI may be reset at
this time. Upon reset the multiplying relays will de-energize.
D. Neither CLS HI or CLS "I8 may be reset at this time. The multiplying relays are
energized.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
- 60. (32.1.1 1 NIN)I/3//TECII
_.
._ SPECWC/A 3.0/3.8/N/SR~301IRII\\II~/~DR
-
The following Unit 1 conditions exist:
- Plant is at 74% power after just completing a rapid power reduction due to Heater
Brain Pump problems
- Axial Flux Difference was outside of the Target Band on 11/03/2003 from 0800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br />
to 0845 hours0.00978 days <br />0.235 hours <br />0.0014 weeks <br />3.215225e-4 months <br />
- Axial Flux Difference was outside of the Target Band on 11/04/2083 from 0748 hours0.00866 days <br />0.208 hours <br />0.00124 weeks <br />2.84614e-4 months <br />
to 0840 hours0.00972 days <br />0.233 hours <br />0.00139 weeks <br />3.1962e-4 months <br />
- The Axial Flux Difference has remained within the Technical Specification kimiits of
Figure 3.12-3, Axial Flux Difference Limits As A Function Of Rated Power, for the
entire time
Which ONE of the following actions are required by Technical Specifications?
A." Reactor power was required to be less than 50% by 0825 hours0.00955 days <br />0.229 hours <br />0.00136 weeks <br />3.139125e-4 months <br /> OR 11/04/2003.
5. Reactor power was required to be less than 50% by 8855 hours0.102 days <br />2.46 hours <br />0.0146 weeks <br />0.00337 months <br /> on 11/04/2003.
C. Reactor power was required to be less than 50% by 091 0 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> OR 11/04/2003.
D. No power reduction was required, but power should not have been raised above
75% until Axial Flux Difference was within the Target Band.
Surry Nuclear Plant 2084-301
DRAFT RO lnital Exam
The following conditions exist:
~
Unit 1 has been shutdown for 10 days for SG tube plugging
- WCS water level is being maintained at 12.4 Beet its indicated on 1 -RC-LI-l OOA
~ The "B" and "C
loops are isolated with the primary and secondary SG manways
removed for SG tube plugging
- The reactor vessel head is tensioned
- The "A" RHR pump is in operation with oscillating amperage indications
~
Flow indication 1-RH-FI-1605 is oscillating between 2500 and 2700 gpm.
Which ONE of the following actions is appropriate for the SWO to direct in accordance
with AP-27.00, Loss of Decay Heat Removal Capability?
(AP-27.60 Attachments 1 and 2 provided)
A. Raise RCS level to 12.5 feet as indicated on 1-WC-LI-I OOA and stabilize Flow at
2600 gpm.
B. Throttle open f-RH-HCV-1758 and throttle close I-RH-FCV-1605 to reduce RHR
flow to 2208 gpm.
C. Throttle close 1-RH-HCV-1958 and throttle open 1-RH-FCV-1605 to reduce RHR
flow to 1200 gpm.
D: Throttle close 1 -RH-FCV-I 605 to reduce WHR flow to 2200 gpm and raise level to
12.5 feet as indicated on 1 -RC-LI-1 OOA.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
Surry
References:
1 -AQ-27.00, Loss of Decay Heat Removal Capabilityy, Rev. 18
ND-88.2-LP-1, Residual Heat Removal System Description, Rev. 8
NB-88.2-LP-632, Operation of Residual Heat Removal System, Rev. 15
ND-95.2-LP-12, Loss of RHR Events, Rev. 9
Distractsr Analysis:
A. Incorrect because AP-27 Att. 2 indicates that 12.5 feet is in the unacceptable region
of operation for 2600 gpm RHR flow rate.
B. Incorrect because AP-27 Att. 2 indicates that 2200 gpm RHR flow rate is in the
unacceptable region of operation for 12.4 feet.
@. lncorrect because AP-27 AH. 1 indicates that 1200 gpm RHR flow rate is less than
the required flow rate of 2200 gpm.
D. Correct because these actions place the plant in an acceptable region of AP-27 Att.
1 and 2 for required flow rate for 10 days after shutdown.
AP-27 Att. 1 and 2 will need to be provided to the applicant.
G2.1.25: Ability to obtain and interpret station reference materials such as graphs,
monographs, and tables which contain performance data.
Surry Nuclear Plant 2004-381
DRAFT RO lnital Exam
Which ONE of the following is correct with respect to Technical Specifications?
A. The Safety Limit for core thermal power is 109% of Rated Thermal Power and the
RCS pressure limit is 2735 psig.
E?. The Safety Limit for core thermal power is 109% of Rated Thermal Power and the
single loop loss of flow reactor trip shall be unblocked when power range nuclear
flux is greater than or equal to 50% of Rated Thermal Power.
C: The reactor trip on low pressurizer pressure, high pressurizer level, turbine trip, and
tow reactor coolant flow for Bwo or more loops shall be unblocked when power is
greater than or equal to 10% or Rated Thermal Power.
D. The source range high flux, high setpoint trip shall be unbiocked when the
intermediate range nuclear flux is less than or equal to 5 ~ 1 8 - ~
amperes.
Surry
References:
Technical Specification 2.1 (Amendments 11 6); 2.2 (Amendments 283); 2.3
(Amendments 175, 176, 206)
Distractor Analysis:
A. Incorrect because the safety limit for core thermal power is 11 8%.
B. incorrect because the safety limit for core therma! power is 11 8%.
C. Correct because this is the correct statement taken from Tech Specs.
B. Incorrect because source range high flux, high setpoint trip shall be unblocked when
the intermediate range nuclear flux is less than or equal to 5x1 CY amperes.
Generic WA 2.2.22
Knowledge of limiting conditions for operations and safety limits.
Sur9 Nuclear Plant 2004-301
DRAFT RO lnital Exam
63. G2.2.27 001/3//lW.E7ELINGIMEM 2.hi3.S/~/SR04301/Rm/IhB/SDK
-
Which ONE of the following correctly states the level of authorization needed for
bypassing the Manipulator Crane Overload Interlock?
A. Refueling SRO or Fuel Handling Supervisor
B. Refueling SWO and Shift Supervisor
C:' SNSOC and Refueling SWO
D. SNSOConly
I
~
1
I
-~
-
_ .
-~
References:
VPAP-1401, Conduct of Operations, Rev. 11 (Section 6.5)
Distractor Analysis:
A. Incorrect because SMSOC pre-approval is needed per 1-OP-FH-015 Step 4.12.
B. Incorrect because SNSOC pre-approval is needed per I-OP-FH-015 Step 4.12.
C. Correct because SRO approval is needed per 1-OP-FH-015 Step 4.10 AND
8. Incorrect bemuse SRO approval is needed per 1-OQ-FH-015 Step 4.10.
SNSOC pre-approval is needed per 1 -OP-FH-015 Step 4.1 2.
G2.2.27
Knowledge of the refueling process.
Surry Nuclear Plant 2084-381
DRAFT RO lnital Exam
64. G2.3.10 001/3//FIJEL HANDLINGIXlEM Z.C)/3,3/N/SR03301/R/MAI?I/SDR
.-
The following conditions exists:
- Unit 2 is at full power
- Unit 1 is in refueling
- Fuel repair is being performed
A damaged fuel rod is raised Boo close to the surface of the water
- Area radiation monitors alarm in the vicinity of the fuel movements
~ Operators enter 0-AP-22.80, Fuel Handling Abnormal Conditions
- All components operate as designed
Which ONE of the following are immediate actions sf AP-22.00?
A:' Stop fuel handling operations, Secure Normal MCR Ventilation by cissing
1 -VS-MOD-l03C and 1 -VS-MOD-I 833, Dump Cable Vault Air Bottles by closing
1 -VS-MOD-l03B.
B. Stop fuel handling operations, Secure Normal MCR Ventilation by closing
1 -VS-MOQ-l03C and 1 -VS-MOD-I 03D, Dump MER 3 Air Bottles by closing
1 -VS-MOB-l03A.
C. Evacuate the affected areas, Secure Normal MCR Ventilation by closing
l-VS-MOB-103C and I-VS-MOD-I03D, Dump MEW 3 Air Bottles by closing
1 -VS-MOD-l03A.
D. Stop fuel handling operations, Evacuate the affected areas, Stop Main Control
Room Fans ____
1 -VS-F-I
.
5 and 1 -VS-AC-4.
Surry
References:
0-AP-22.00, Fuel Handling Abnormal Conditions, Rev. I8
Distractor Analysis:
A. Correct these are all listed as immediate actions of AP-22.80.
B. Incorrect because 1 -VS-MOD-l03A is in the BNO column to be performed if 1035
does not close. However, the stem states that all equipment operates as designed,
so the operator would not go to the RNO column.
C. Incorrect because 1 -VS-MOD-l03A is in the RNQ column to be performed if 10383
does not close.
B. incorrect because stopping MCR Ventilation Fans is not an immediate action.
G2.3.10: Ability to perform procedures to reduce excessive levels of radiation and
guard against personnel exposure.
Surry Nuclear Plant 2004-301
DRAFT f%O lnital Exam
Work in a radiation area must be performed. The following conditions exist:
- A point source is present and emits 50 mrern/hour at 1 foot
- The air has a Derived Air Concentration (DAC) of 10
Which ONE of the following methods will result in the lowest amount of accumulated
dose?
A. Two workers using hand tools can perform the work in one hour at a distance of two
feet wearing no respirator^
3. Three workers using remote tools perform the work in two hours at a distance of six
feet wearing no respirator.
C. Two workers using hand tools pedforrn the work in four hours at a distance of two
feet wearing a respirator with a protection factor of 50.
D? Three workers using remote tools perform the work in 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> at a distance of six
feet wearing a respirator with a protection factor of 50.
Surry
References:
Dominion Nuclear Employee Training Manual Volume II EWWT, RBT, CSET, SCAT,
FWT, Rev. 7 1, Januaryy, 2083.
Distractor Analysis:
A. Incorrect: 75 mrem 5 56.7 mrem. {[(2 rnen)(l hr)(50nnrem/hr)(l/2)2]+[(60 DAC)
B. Incorrect: 658.3 mrern z 56.7 mrem. {[(3 men)(2 hr)(50narem/hr)(l/6)2]+[(1 6 DAC)
C. Incorrect: 104 mrem z 56.7 mrem. ([(2 men)(4 hr~(50mrem/~r)(l/6)2]+[(10
DAC)
D. Correct: [(3 rnen)(lO hrs)(50 mrem/hr)(l/6)2] c [(lo DAC)(1/58)(3 m@n)(10 krs)(2.5
(2 men)(l hr)(2.5 mrernlDAC-PIR)] = 75 rnrern)
(3 men)(2 hr)(2.5 rnrem/BAC-HW)] = 158.3 mrem)
(1/50)(2 men)(4 hj(2.5 mrern/DAC-HR)] = 104 rnrem}
rnrem/l DAC-HW)] = 41.7 + 15 = 56.7 mrem.
G2.3.2
Knowledge of facility ALARA program.
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
The following Unit 1 conditions exist:
- The WGS temperature is 198 OF.
- Operators are performing Section 5.2 of 1 -OP-VS-OOl, Containment Ventilation, to
place the Containment Purge System in service using 1 -VS-F-58A or 1 -VS-F-58BP
Filter Exhaust Fans.
The Containment Purge Form requires 5000 cfm purge flow.
Which ONE of the following correctly states selection criteria, in accordance with
1-OP-VS-001, for choosing which valve to use for obtaining the correct purge flow
rate?
A. 1-VS-MOV-1005 (Ctmt Purge Exh) Should be throttled instead of 1-VS-MOV-161
(Ctmt Purge B/P) due to the high flow rate required by the Containment Purge
Form.
B. I-VS-MOV-101 (Gbmt Purge B/P) should be throttled instead of 1 -VS-MBV-I 00D
(Ctrnt Purge Exh). Phis is due to the need to open the supply breaker to
1 -VS-MOV-lOOD in order to throttle it. Opening the breaker will prevent automatic
CTMT Purge isolation.
C. 1 -VS-MOV-I 01 (Ctmt Purge B/PJ should be throttled instead of l-VS-MBV-100D
(Ctrnt Purge Exh) due to the low flow rate required by the Containment Purge
Form.
B. 1 -VS-MOV-l 00D (Ctrnt Purge Exh) should be throttled instead of 1 -VS-MOV-I 01
(Ctrnt Purge WP). This is due to the need to open the supply breaker to
1 -VS-MBV-101 in order to throttle it. Opening the breaker will prevent automatic
CTMT Purge isolation.
Surry Nuclear Plant 2004-306
DRAFT RO lnital Exam
Surry
References:
1 -OQ-VS-001~
Containment Ventilation, Rev. 20
Distractor Anaiysis:
A. Correct because 100D shouid be throttled due to the Containment Purge Form
allowing more than 3000 cfm. The bypass will not have enough capacity at this
flow sate.
B. Incorrect because even though auto containment purge isolation will not occur with
the breaker open, the procedure still directs the use of 100D due to the high flow
rate. Plausible because applicant may think it logical to not intentionally
incapacitate auto containment isolation.
Plausible because 3000 gpm is not a very high flow rate.
procedure directs 101 to be used for fine tuning the flow rate. Plausible because
preventing auto ctmt purge isolation is a concern when using 10OD.
C. Incorrect because with the flow rate greater than 3000 gpm, 10OD should be used.
D. Incorrect because the bkr does not need to be opened and at 5000 gpm, the
62.3.9: Knowledge of the process for performing a containment purge.
Surry Nuclear Plant 2004-301
DRAFT R 8 lnital Exam
67. G2 4.1 I 001/3//ABNORMAL
- __
_. PR=EDURE/MEM
-~
~ 3 4/3.6/N94301/R/MAEl/SDK
._
_
_
_
_
~
- -
Which ONE of the following correctly states the requirements for performing immediate
action steps within emergency procedures?
A. immediate action steps must be performed in the order in which they appear in any
procedure.
B. Immediate action steps may be performed in any order, except for the first four
immediate action steps of E-0, Reactor Trip or Safety Injection, which must be
performed in the order in which they appear in the procedure.
CY Immediate action steps may be performed in any order except for the first four
immediate action steps of E-0, Reactor Trip or Safety Injection, and the immediate
action steps of FW-S.l, Response to Nuclear Generation / ATWS, which must be
perfomed in the order in which they appear in the procedure.
B. Immediate action steps may be performed in any order except for the immediate
actio^ steps of FR-S.1, Response to Nuclear Generation / ATWS, and ECA-0.0,
boss of All A 6 Power, which must be performed in the order in which they appear in
the procedure.
Surry
References:
ND-95.3-LP-2, Emergency Procedure Writer's Format, Rev. 8
(Have Utility add any addional references that may support answer.)
Distractor Analysis:
A. Incorrect because only immediate actions of E-0 and FR-S.1 must be performed in
the order in which they appear in the procedure.
B. Incorrect because only immediate actions of E-8 and FR-55.1 must be performed in
the order in which they appear in the procedure.
C. Correct because immediate actions of E-Q and FR-S.1 must be performed in the
order in which they appear in the procedure. This requirement / expectation is
stated in ND-95.3-LP-2 Page 12.
D. Incorrect because ECA-0.0 are not required to be performed in any specific order.
G2.4.11: Knowledge of abnormal condition procedures.
Susry Nuclear Plant 2004-301
DRAFT RO M a l Exam
A situation presents itself that requires a Reactor Operator (RO) to take quick decisive
action to ensure Station Safety. Personnel are not in immediate danger and the action
requires no reactivity manipulations.
Which ONE of the following correctly describes the requirements for performing the
1
actions?
A! The WQ may take necessary action without prior approval from another licensed
operator.
B. The RO must immediately request approval from the Unit SRO to perform the
C. The RO may take action only after another licensed operator has been notified and
action and only take action after approval is granted.
concurs with the action.
I
D. The RO may take action only after obtaining a peer check to concur with the action.
References:
OPAP-8006, Shift Operating Practices, Rev. 4
Distractor Analysis:
A. Correct because OPAP-0006 Step 6.1 8.3 states, "During emergencies, Shift Team
members may take necessary immediate actions required to ensure personnel and
Station safety without prior approval. The Shift Supervisor shall be promptly
informed of these actions."
B. Incorrect because action may be taken prior to obtaining permission.
C. Incorrect because action may be taken prior to notifying or obtaining permission
B. Incorrect because immediate action is authorized to protect the Station.
from another Team Member.
G2.4.92: Knowledge of general operating crew responsibilities during emergency
operations.
Sur9 Nuclear Plant 2004-301
DRAFT 80 lnital Exam
69. G2.4.49 0 0 2 I 3 N R Q D I N ~ R O ~ A
~
4.OM
.~
O/N/SK04301(RA/IAR/SDK
~
~
~
~
-
Given the following conditions:
Reactor Power = 85%
- Control Rods are in automatic
- Control Bank D begins to insert without a turbine runback
- Yave and Tref are matched within 8.5 "F
P -
Which ONE of the following describes the correct immediate operator response to
these conditions?
A. Verify quadrant power tilt and axial flux difference within limits.
BY Place ROD CONT MODE SEL switch in MANUAL.
C. Manually trip the reactor.
D. Verify lWPl operating properly.
Sur9
We fe re RC8S :
0-AP-1 .00, Rod Control System Malfunction, Rev. 9.
Distractor Analysis:
A. Incorrect because the initial response is to place ROB CONT MODE SEL switch in
B. Correct per AP-1 .00.
C. Incorrect because this would not be pedOrM@d until ROD CONT MODE SEL switch
D. Incorrect because AP-I .a30 directs placing ROD CBNT MODE SEI. switch in
MANUAL.
was placed to MANUAL and rod motion had stopped.
MANUAL as an immediate action.
G2.4.49
Ability to perform without reference to procedures those actions that require immediate
operation of system components and controls.
Sur9 Nuciear Plant 2804-301
DRAFT RO lnital Exam
90. WEOIEK3.2 001/1/1/EOCA
-
~ OIJZSIDEKYA
_. 3.4/4.0/M/SR04301/R/I\\~SL)R
~
__
~
~
,
-
-
~
!
Which ONE of the following correctly states actions contained in I-ECA-I 2,
Outside Containment, and the reasons for those actions?
I
I
A. Open l-SI-MOV-1890A (LHSI to Hot Leg) or l-SI-MOV-189QB (LHSI to Hot Leg) to
provide a flow path for Low Head Safety injection. Then close 1 -SI-MOV-l890C
(LHSI to Cold Legs) and monitor RCS pressure.
B. If closing I-SI-MOV-189OC (LHSI to Cold Legs) does not result in an RCS pressure
rise then allow it to remain closed because this will give operators time to check Aux
Building alarms while the flow path is isolated.
C. If the leak is not identified and isolated then transition to 1 -E-1 , Loss of Reactor or
Secondary Coolant, because RCS inventory is continued to be lost outside of
containment.
D I If closing 1 -SI-MOV-I890C (LHSB to Cold Legs) results in an RCS pressure rise,
then place the LHSl pumps in PTL because their suction valves from the RWST will
be ~losed
to isolate potential leak paths.
Sur9
Ref@ rences:
ND-95.3-LP-21, ECA-I .2 LOCA Outside Containment, Rev. 7
ECA-1.2, LOCA Outside Containment, Rev. 5
Distractor Analysis:
A. Incorrect because ECA-1.2 does not give any direction to open l-SI-MOV-1890A &
B. These valves should be left in the closed position. This distractor is plausible
because EGA-1.2 does give guidance to close 189OC.
decreasing, then the leak was not isolated and the valve needs to be ae-opened.
This is the normal SI flow path and it is important to re-establish this path if closing
the valve did not isolate the leak.
C. Incorrect because if the leak is not isolated, then the correct transition would be to
go to 1 -ECA-l.l, Less of Emergency Coolant Recirculation.
B. Correct because if RCS pressure rises upon closure of 1 -SI-MOV-I 89QC,
then the
leak was isolated and 1-ECA-1.2 directs the LHSl pumps to be placed in PTL and
the suction valves from the RWST to be closed.
B. Incorrect because if l-SI-MOV-I89OC is closed and RCS pressure is still
WE84
EK3.2: Knowledge of the reasons for the following responses as they apply to the
(LOCA Outside Containment): Normal, abnormal, and emergency operating
procedures associated with (LQCA Outside Containment).
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
71 .
~ WBOGEK3. I 001/1/2/COWE COOLINGhlEM 3.4/3.8/B/SR04301IWMAB/SDR
.~
~-
-
__.
~
_
_
~
1-FR-C.1, Response to Inadequate Core Cooling, is being performed. Which ONE of
the following is the reason RCPs are stopped prior to depressurizing the SGs to less
then 150 psig during an inadequate core cooling event?
A. RCP operation with the SGs at atmospheric pressure is prohibited due to excessive
hydraulic stress on the SG bl-tubes.
B. The SGs will depressurize more quickly if no Forced Circulation RCS flow exists.
C. To minimize heat input to the RCS.
Dr' The SG depressurization will lead to a loss of RCP support conditions.
References:
ND-95.3-LP-38, Response to Inadequate Core Cooling, Rev. 8
FR-C.1, Response to Inadequate Core Cooling, Rev. 18
Distractor Analysis:
A. Incorrect besause securing RCPs is necessary because the depressurization will
result in losing the RCP seal support conditions, which could damage the RCPs.
B. Incorrect because the basis for securing WCPs is not associated with heat input into
the WCS or forced flow.
C. Incorrect because the basis for securing RCPs is not associated with heat input into
the RCS.
D. Correct because this is the stated reason in ND-95.3-LP-38. Losing #I Seal
support Conditions could result in damage to the RCPs.
074 Inad. Core Cooling
E06EK3.1: Knowledge of the reasons for the following responses as they apply to
(Degraded Core Cooling): Facility operating characteristics during transient conditions,
including coolant chemistry and the effects of temperature, pressure, and reactivity
changes and operating limitations and reasons for these operating characteristics.
Surry Requal Exam Bank Question #467
Surry Nuclear Plant 2084-301
DRAFT RQ lnital Exam
The following Unit 1 conditions exist:
~ Reactor power is 58% and rising
- RCS pressure is at 221 8 psig and slowly lowering
- Tavg is 557 'F and slowly lowering
- Pressurizer level is slowly lowering
- Turbine load is stable at 400 MW
- SG levels are at 46% NR
- Sei pressures are at 990 psig and slowly lowering
~ Containment pressure is 9.5 psia and slowly rising
- Condenser Air Ejector RM reads 18 cpm
Which ONE of the following correctly diagnoses the event?
A. Ruptured and faulted steam line break inside containment.
B:' Steam line break inside containment.
6. LOCA inside containment.
D. Steam line break outside containment.
~
~
~
~
__
Surry Nuclear Plant 2004-301
DRAFT RO lnital Exam
Surry
References:
General operator knowledge.
B i st racto r Analysis :
A. Incorrect because although there are parameters to support the steam line break,
there are no parameters to support a SGTR. Plausible because Condenser Air
Ejector RM reading is given, but the value is not representative of a SGTR.
B. Correct because reactor power and ctmt pressure are rising; WCS pressure, Tavg,
and SG pressures are lowering. These are all indicative of a steam line break
inside ctrnt.
C. Incorrect because reactor power would not be rising during a LOCA as it would
during a steam line break. Plausible because many of the parameters coincide with
a LOCA.
D. incorrect because ctmt pressure is rising. Plausible because of the aforementioned
parameters that are indicative of a steam line break.
WE08 RCS Overcooling
G2.1.7: Ability to evaluate plant performance and make operational judgements based
on operating characteristics, reactor behavior, and instrument interpretation.
SurBy Requal Bank Question #I 77 (ID: EOPOIB76)
Surry Nuclear Plant 2084-301
DRAFT RO lnital Exam
-~
73. WE1 IEAI 2 ._
00111/1/LIISI
.~
1,OCAXST IIIISI/C/A 3.5/3S/N/SW301M>/SDR
__
The following conditions exist:
- LOCA Ras occurred.
~
RWST level = 13% and decreasing.
- Recirculation Mode Transfer (RMT) keyswitch is in RMT M ~ d e .
- White RMT Status Light is lit.
- Amber RMT Status Light is lit.
I-SI-MOV-I$6QA (LHSI Suction from Sump) opens fully and 1 -Sl-MOV-18608 (LHSI
Suction from Sump) strokes to 58% open where it trips on thermal overload. Which
ONE of the following gives the correct status of Safety Injection?
A.' LHSB from the RWST is injecting into the cold legs and HHSl from LHSl pump
discharge is injecting into the cold legs.
3. No Safety Injection is injecting water to the cold legs.
C. HHSl directly from the RWST (not from LHSl discharge) is injecting into the cold
legs, but no LHSI is injecting into the cold legs.
D. LHSI from the WWST and HHSl directly from the RWST (not from LHSI discharge)
is being injected into the cofd legs.
Surry
References:
ND-91.3-bP-3, Safety Injection System Operations, Rev. 15
1 -ES-l.3,
Transfer to Gold beg Recirculation, Rev. 1 1
Distractor Analysis:
A. Correct because 1 -SI-MQV-1 862A&5 will not close until 1 -SI-MOV-I 860A&B open
B. incorrect because RWSP is still the suction source to the LHSl pumps.
C. Incorrect because bHSl Pumps are taking suction from the RWST and injecting into
D. Incorrect because HHSl is not taking suction directly from the RWST. HHSl is
due to an interlock.
the cold legs and HHSl is not taking suction directly from the RWST.
taking suction on the discharge of the LHSB Pumps.
WE1 1
EA1 2: Ability to operate and i or monitor the following as they apply to the (Loss of
Emergency Coolant Recirculation): Operating behavior characteristics OB the facility.
Sur9 Nuclear Plant 2004-301
DRAFT WO lnital Exam
~
I
74. WE I2EK2.2 00 Ill! 1IAFWIMEM
_. 3.6/3.96~SR0430IIRIMI\\RISL)R
__
~
_
_
~
~.
r - -
A steam break has occurred and all Steam Generators are faulted.
Which ONE of the following is the basis for maintaining a minimum of 60 gpm AFW
flow to each Steam Generator per ECA-2.1, Uncontrolled Depressurization of All
1
A. 60 gpm is needed to meet minimum heat sink flow requirements.
B. 60 gpm to each Steam Generator will ensure even thermal hydraulic distribution
across the core.
CY 60 gpm is the minimum indicated flow rate to prevent Steam Generator dryout.
D. 68 gpm is the minimum indicated flow that will ensure the feed lines stay warm to
prevent excessive therm! shock to the feed lines during recovery actions.
References:
ND-95.3-LP-22, ECA-2.1 Uncontrolled Depressurization of All Steam Generators,
14-3, ECA-2.1~
Uncontrolled Depressurization of All Steam Generators, Rev. 16
Rev. 9
Distractor Analysis:
A. lncorreet because this requirement is not based on minimum heat sink flow
6. Incorrect because this requirement is not based on thermaE hydraulic distribution
C. Correct because 60 gpm is the minimum verifiable flow rate to a steam generator.
requirements, it is based on SG d9out.
across the core. It is based on S/G dryout.
This ensures a nominal flow rate of 25 gpm to the S/G, considering detector
uncertainties, to prevent dryout and thermal shock to the S/G.
D. lncsrrect because the concern is with thermal shock to the SG if AFW flow rates are
rasied.
040 (WIE12) Steam Line Rupture
~ Excessive Heat Transfer
EK2.2: Knowledge of the interrelations between the (Uncontrolled Depressurization of
All Steam Generators) and the following: Facility's heat removal systems, including
prima9 coolant, emergency coolant, the decay heat removal systems, and relations
between the proper operation of these systems to the operation of the facility.
Modified Surry ILP Bank Question #lo1 0
Surry Nuclear Plant 2004-301
DRAFT WO Bnitat Exam
75. WE1 3EK2.1 -
001/1/2/SGTR OVEWIGSSIJRWMEM 3.0/3 I/M/SR04*IUMA%SDRp
._ -
~- -
I
1-E-3, Steam Generator Tube Rupture, has been entered due to a ruptured tube in the
"A" Steam Generator. The Team is performing Step 4, which directs "A" Steam
Generator Narrow Range SG Level to be greater than 12% prior to stopping feed flow.
Which ONE of the following correctly states the basis for this step?
i
A! To ensure that the ruptured steam generator tubes are covered to promote thermal
stratification.
5. To ensure thermal gradients across the tubes of the ruptured steam generator do
not exacerbate existing tube damage.
C. To ensure sufficient heat sink for reactor coolant system cooldown.
D. To prevent excessive primary to secondary leakage.
~
_
_
_
~
~~~
-
-
~
_
_
Surry
References:
1 -E-3, Steam Generator Tube Rupture, Rev. 25
NB-95.3-LP-13, E-3 Steam Generator Tube Rupture, Rev. 11
Distractor Analysis:
A. Correct because this is the basis as stated in ND-95.3-LP-13.
B. Incorrect because the comcern is not thermal gradients across the tubes. The
concern is to cover the tubes for thermal stratification and then stop AFW flow as
soon as the tubes are covered to give margin to overfill, while mitigating release to
the public.
@. Incorrect because this SG will not be used for the RCS cooldown.
3. Incorrect because the dP is still going Bo induce leakage even at 12% SG level.
WE1 3 Steam Generator Over-pressure
EK2.1: Kno~ledge of the interrelations between the (Steam Generator Overpressure)
and the following: Components, and functions of control and safety systems, including
instrumentation, signals, interlocks, failure modes, and automatic and manual features.
Question is modified from a Braidwssd Question.