June 23, 2003 LICENSEE:

Florida Power and Light Company FACILITY:

St. Lucie Nuclear Station, Units 1 and 2

SUBJECT:

SUMMARY

OF A TELEPHONE CALL BETWEEN THE NRC AND THE FLORIDA POWER AND LIGHT COMPANY CONCERNING SUPPLEMENTAL RESPONSE TO SAFETY EVALUATION REPORT WITH OPEN ITEMS PERTAINING TO ST. LUCIE, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. MB3406 AND MB3412)

The NRC staff (hereafter referred to as staff) and representatives of the Florida Power and Light Company (FPL or the applicant) held a telephone call on June 17, 2003 to clarify FPLs response to an open item in the Safety Evaluation Report (SER) with Open Items issued on February 7, 2003. On the basis of the discussion, the applicant plans to revise its supplemental response to the open item. No staff decision was made during the telephone call. A summary of the discussion and the applicants proposed action is presented below:

Open Item 3.1.2.2-1, Pressurizer Nozzle Thermal Sleeves On June 17, 2003, the staff and the applicant discussed Open Item 3.1.2.2-1 regarding the aging management review for the pressurizer surge and spray nozzle thermal sleeves. The staff questioned whether circumferential cracking of the thermal sleeves is an applicable aging effect. As a result of this phone call, the applicant agreed to revise its response to this open item.

A draft copy of this summary was provided to the applicant to allow it the opportunity to comment prior to the summary being issued. A list of the participants for the telephone call is provided in the enclosure.

/RA/

Tilda Y. Liu, Project Manager License Renewal Section License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos: 50-335 and 50-389

Enclosure:

As stated

June 23, 2003 LICENSEE:

Florida Power and Light Company FACILITY:

St. Lucie Nuclear Station, Units 1 and 2

SUBJECT:

SUMMARY

OF A TELEPHONE CALL BETWEEN THE NRC AND THE FLORIDA POWER AND LIGHT COMPANY CONCERNING SUPPLEMENTAL RESPONSE TO SAFETY EVALUATION REPORT WITH OPEN ITEMS PERTAINING TO THE ST. LUCIE, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. MB3406 AND MB3412)

The NRC staff (hereafter referred to as staff) and representatives of the Florida Power and Light Company (FPL or the applicant) held a telephone call on June 17, 2003 to clarify FPLs response to an open item in the Safety Evaluation Report (SER) with Open Items issued on February 7, 2003. On the basis of the discussion, the applicant plans to revise its supplemental response to the open item. No staff decision was made during the telephone call. A summary of the discussion and the applicants proposed action is presented below:

Open Item 3.1.2.2-1, Pressurizer Spray Nozzle Thermal Sleeves On June 16, 2003, the staff and the applicant discussed Open Item 3.1.2.2-1 regarding the aging management review for the pressurizer surge and spray nozzle thermal sleeves. The staff questioned whether circumferential cracking of the thermal sleeves is an applicable aging effect. As a result of this phone call, the applicant agreed to revise its response to this open item.

A draft copy of this summary was provided to the applicant to allow it the opportunity to comment prior to the summary being issued. A list of the participants for the telephone call is provided in the enclosure.

/RA/

Tilda Y. Liu, Project Manager License Renewal Section License Renewal and Environmental Impacts Program Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket Nos: 50-335 and 50-389

Enclosure:

As stated DISTRIBUTION:

See next page

  • See previous concurrence Accession no.: ML031740717 Document Name: C:\\ORPCheckout\\FileNET\\ML031740717.wpd OFFICE PM: RLEP/DRIP PM: RLEP/DRIP LA:RLEP/DRIP SC:RLEP/DRIP NAME TLiu*

NDudley*

YEdmonds*

SLee*

DATE 6/18/03 6/19/03 6/23/03 6/23/03 OFFICIAL RECORD COPY

DISTRIBUTION: Summary of Telephone Call w/FPL, Dated: June 23, 2003 ML031740717 HARD COPY RLEP RF N. Dudley T. Liu E-MAIL:

PUBLIC W. Borchardt D. Matthews F. Gillespie C. Grimes RidsNrrDe E. Imbro G. Bagchi K. Manoly W. Bateman J. Calvo P. Shemanski H. Nieh H. Walker S. Black B. Boger D. Thatcher R. Pettis G. Galletti C. Li J. Moore R. Weisman M. Mayfield A. Murphy W. McDowell S. Smith (srs3)

S. Duraiswamy C. Munson RLEP Staff J. Medoff S. Coffin

LIST OF PARTICIPANTS TELEPHONE CALL WITH FLORIDA POWER AND LIGHT COMPANY ST. LUCIE, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION June 17, 2003 Participants Affiliation Noel Dudley NRC Tilda Liu NRC James Medoff NRC Stephanie Coffin NRC Tony Menocal FPL Steve Hale FPL Enclosure

ST. LUCIE PLANT Florida Power and Light Company cc:

Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Senior Resident Inspector St. Lucie Plant U.S. Nuclear Regulatory Commission P.O. Box 6090 Jensen Beach, Florida 34957 Mr. Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 M. S. Ross, Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Douglas Anderson County Administrator St. Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982 Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741 Mr. William Jefferson, Jr.

Site Vice President St. Lucie Nuclear Plant 6501 South Ocean Drive Jensen Beach, Florida 34957 Mr. R. E. Rose Plant General Manager St. Lucie Nuclear Plant 6501 South Ocean Drive Jensen Beach, Florida 34957 Mr. J. T. Voorhees Acting Licensing Manager St. Lucie Nuclear Plant 6501 South Ocean Drive Jensen Beach, Florida 34957 Mr. Don Mothena Manager, Nuclear Plant Support Services Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. J. Kammel Radiological Emergency Planning Administrator Department of Public Safety 6000 SE. Tower Drive Stuart, Florida 34997 Attorney General Department of Legal Affairs The Capitol Tallahassee, Florida 32304 Mr. Steve Hale St. Lucie Nuclear Plant Florida Power and Light Company 6351 South Ocean Drive Jensen Beach, Florida 34957-2000 Mr. Fred Emerson Nuclear Energy Institute 1776 I Street, N.W., Suite 400 Washington, DC 20006-3708 Mr. David Lewis Shaw Pittman, LLP 2300 N Street, N.W.

Washington, D.C. 20037