Table of Contents APPENDIX B AGING MANAGEMENT PROGRAMS APPENDIX B AGING MANAGEMENT PROGRAMS..............................................

B-1 B.1 AGING MANAGEMENT PROGRAMS EVALUATED IN NUREG-1801. B-6 B.1.1 ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD......................................................................................

B-6 B.1.2 Water Chemistry.............................................................................

B-9 B.1.3 Reactor Head Closure Studs..........................................................

B-11 B. 1.4 BWR Vessel ID Attachment Welds................................................

B-13 B.1.5 BWR Feedwater Nozzle......................................................................

B-15 B.1.6 BWR Control Rod Drive Return Line Nozzle..................................

B-16 B.1.7 BWR Stress Corrosion Cracking...................................................

B-18 B. 1.8 BWR Penetrations...............................................................................

B-20 B.1.9 BWR Vessel Internals..........................................................................

B-22 B.1.10 Thermal Aging and Neutron Irradiation Embrittlement of Cast Austenitic Stainless Steel (CASS)...............................................

B-24 B.1.11 Flow-Accelerated Corrosion.................................................................

B-25 B.1.12 Bolting Integrity....................................................................................

B-27 B.1.13 Open-Cycle Cooling Water System.....................................................

B-29 B.1.14 Closed-Cycle Cooling Water System...................................................

B-31 B.1.15 Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems...................................

B-33 B.1.16 Compressed Air Monitoring.................................................................

B-35 B.1.17 BWR Reactor Water Cleanup System.................................................

B-37 B.1.18 Fire Protection....................................................................................

B-38 B.1.19 Fire Water System...............................................................................

B-42 B.1.20 Aboveground Carbon Steel Tanks.......................................................

B-44 B.1.21 Fuel Oil Chemistry...............................................................................

B-45 B.1.22 Reactor Vessel Surveillance................................................................

B-47 B.1.23 One-Time Inspection......

B-49 B.1.24 Selective Leaching of Materials...........................................................

B-52 B.1.25 Buried Piping and Tanks Inspection.....................................................

B-54 B.1.26 ASME Section XI, Subsection IWE......................................................

B-56 B.1.27 ASME Section XI, Subsection IWF......................................................

B-58 B.1.28 10 CFR Part 50, Appendix J................................................................

B-59 B.1.29 Masonry Wall Program........................................................................

B-61 B.1.30 Structures Monitoring Program............................................................

B-62 B.1.31 RG 1.127, Inspection of Water-Control Structures Associated with Nuclear Power Plants................................................

B-64 B.1.32 Protective Coating Monitoring and Maintenance Program................... B-66 B.1.33 Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements................... B-68 B.1.34 Metal Fatigue of Reactor Coolant Pressure Boundary......................... B-70 B.1.35 Environmental Qualification (EQ) of Electrical Components................ B-72 B.1.36 Boraflex Monitoring (Quad Cities Only)................................................

B-73 Dresden and Quad Cities Page B-i License Renewal Application

Table of Contents B.2 PLANT-SPECIFIC AGING MANAGEMENT PROGRAMS................... B-74 B.2.1 Corrective Action Program...................................................................

B-74 B.2.2 Periodic Inspection of Non-EQ, Non-Segregated Electrical Bus Ducts...........................................................................................

B-77 B.2.3 Periodic Inspection of Ventilation System Elastomers.......................... B-79 B.2.4 Periodic Testing of Drywell and Torus Spray Nozzles.......................... B-82 B.2.5 Lubricating Oil Monitoring Activities.....................................................

B-84 B.2.6 Heat Exchanger Test and Inspection Activities....................................

B-87 B.2.7 Generator Stator Water Chemistry Activities (Quad Cities Only).......... B-90 List of Tables NUREG-1801 and Dresden and Quad Cities Aging Management Program Matrix..................................................................................................

B-2 Page B-ii Dresden and Quad Cities License Renewal Application B-1

Appendix B AGING MANAGEMENT PROGRAMS APPENDIX B AGING MANAGEMENT PROGRAMS Introduction Section 3 of the LRA identifies the aging management program activities credited for managing aging effects. Section 4 of the LRA identifies the aging management program activities credited as a result of time-limited aging analyses. Appendix B describes the aging management program activities identified in Sections 3 and 4 of the LRA.

Table B-1 provides a list of the aging management programs evaluated in Chapters X and XI of NUREG-1801, "Generic Aging Lessons Learned (GALL) Report,* April 2001, and the corresponding Dresden and Quad Cities programs credited for aging management in this application.

Section BA provides descriptions of program activities and the results of reviews to determine their consistency with the aging management programs evaluated in NUREG-1801. A summary of enhancements to the Dresden and Quad Cities programs as well as exceptions to specific elements of the NUREG-1801 aging management programs are presented. In addition, plant-specific operating experience associated with the program activities is described.

Section B.2 provides evaluations of plant-specific aging management programs.

The aging management program activities are presented under the following headings:

B.1 AGING MANAGEMENT PROGRAMS EVALUATED IN NUREG-1801 B.2 PLANT-SPECIFIC AGING MANAGEMENT PROGRAMS Dresden and Quad Cities Page B-1 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Table B-1 NUREG-1801 and Dresden and Quad Cities Aging Management Program Matrix NUREG-1801 Program Dresden and Quad Cities Appendix B I

Programs Subsection NUREG-1801 Chapter X X.M1 Metal Fatigue of Reactor Metal Fatigue of Reactor Coolant B.1.34 Coolant Pressure Boundary Pressure Boundary X.S1 Concrete Containment Tendon Not Credited for License Renewal Prestress I

X.E1 Environmental Qualification (EQ)

Environmental Qualification (EQ) of B.1.35 of Electrical Components Electrical Components NUREG-1801 Chapter XI XI.M1 ASME Section XI Inservice ASME Section XI Inservice B.1.1 Inspection, Subsections IWB, Inspection, Subsections IWB, IWC, IWC, and IWD and IWD XI.M2 Water Chemistry Water Chemistry B.1.2 XI.M3 Reactor Head Closure Studs Reactor Head Closure Studs B.1.3 XI.M4 BWR Vessel ID Attachment BWR Vessel ID Attachment Welds B.1.4 Welds XI.M5 BWR Feedwater Nozzle BWR Feedwater Nozzle B.1.5 XI.M6 BWR Control Rod Drive Return BWR Control Rod Drive Return Line B.1.6 Line Nozzle Nozzle XI.M7 BWR Stress Corrosion Cracking BWR Stress Corrosion Cracking B.1.7 XI.M8 BWR Penetrations BWR Penetrations B.1.8 XI.Mt BWR Vessel Internals BWR Vessel Internals B.1.9 XI.M10 Boric Acid Corrosion Not Credited for License Renewal I

Dresden and Quad Cities Page B-2 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Table B-1 NUREG-1801 and Dresden and Quad Cities Aging Management Program Matrix (Continued)

NUREG-1801 Program Dresden and Quad Cities Appendix B Programs Subsection XI.M11 Nickel-Alloy Nozzles and Not Credited for License Renewal Penetrations XI.M12 Thermal Aging Embrittlement of Not Credited for License Renewal Cast Austenitic Stainless Steel (CASS)

XI.M13 Thermal Aging and Neutron Thermal Aging and Neutron B.1.10 Irradiation Embrittlement Irradiation Embrittlement of Cast Austenitic Stainless Steel of Cast Austenitic Stainless Steel (CASS)

(CASS)

XI.M14 Loose Part Monitoring Not Credited for License Renewal XI.M15 Neutron Noise Monitoring Not Credited for License Renewal XI.M16 PWR Vessel Internals Not Credited for License Renewal XI.M17 Flow-Accelerated Corrosion Flow-Accelerated Corrosion B.1.11 XI.M18 Bolting Integrity Bolting Integrity B.1.12 XI.M19 Steam Generator Tube Integrity Not Credited for License Renewal XI.M20 Open-Cycle Cooling Water Open-Cycle Cooling Water System B.1.13 System XI.M21 Closed-Cycle Cooling Water Closed-Cycle Cooling Water System 6.1.14 System XI.M22 Boraflex Monitoring Boraflex Monitoring B.1.36 XI.M23 Inspection of Overhead Heavy Inspection of Overhead Heavy Load 6.1.15 Load and Light Load (Related to and Light Load (Related to Refueling)

Refueling) Handling Systems Handling Systems XI.M24 Compressed Air Monitoring Compressed Air Monitoring B.1.16 Dresden and Quad Cities Page B-3 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Table B-1 NUREG-1801 and Dresden and Quad Cities Aging Management Program Matrix (Continued)

NUREG-1801 Program Dresden and Quad Cities Appendix B Programs Subsection XI.M25 BWR Reactor Water Cleanup BWR Reactor Water Cleanup System B.1.17 System XI.M26 Fire Protection Fire Protection B.1.18 XI.M27 Fire Water System Fire Water System B.1.19 XI.M28 Buried Piping and Tanks Not Credited for Ucense Renewal Surveillance XI.M29 Aboveground Carbon Steel Aboveground Carbon Steel Tanks B.1.20 Tanks XI.M30 Fuel Oil Chemistry Fuel Oil Chemistry B.1.21 XI.M31 Reactor Vessel Surveillance Reactor Vessel Surveillance B.1.22 XI.M32 One-Time Inspection One-Time Inspection B.1.23 XI.M33 Selective Leaching of Materials Selective Leaching of Materials B.1.24 XI.M34 Buried Piping and Tanks Buried Piping and Tanks Inspection B.1.25 Inspection XI.S1 ASME Section XI, Subsection ASME Section XA, Subsection IWE B.1.26 IWE XI.S2 ASME Section XI, Subsection Not Credited for License Renewal PJWL XI.S3 ASME Section XA, Subsection ASME Section XA, Subsection IWF B.1.27 IWF I

I XI.S4 10 CFR Part 50, Appendix J 10 CFR Part 50, Appendix J B.1.28 Page B-4 Dresden and Quad Cities License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Table B-1 NUREG-1801 and Dresden and Quad Cities Aging Management Program Matrix (Continued)

NUREG-1801 Program Dresden and Quad Cities Appendix B Programs Subsection XI.S5 Masonry Wall Program Masonry Wall Program B.1.29 XI.S6 Structures Monitoring Program Structures Monitoring Program B.1.30 XI.S7 RG 1.127, Inspection of Water-RG 1.127, Inspection of Water-B.1.31 Control Structures Associated Control Structures Associated with with Nuclear Power Plants Nuclear Power Plants XI.S8 Protective Coating Monitoring Protective Coating Monitoring and B.1.32 and Maintenance Program Maintenance Program XI.EI Electrical Cables and Electrical Cables and Connections B.1.33 Connections Not Subject to 10 Not Subject to 10 CFR 50.49 CFR 50.49 Environmental Environmental Qualification Qualification Requirements Requirements XI.E2 Electrical Cables Not Subject to Not Credited for License Renewal 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits XI.E3 Inaccessible Medium Voltage Not Credited for License Renewal Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements I

Dresden and Quad Cities Page B-5 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1 AGING MANAGEMENT PROGRAMS EVALUATED IN NUREG-1801 B.1.1 ASME Section XI Inservice Inspection, Subsections IWB, IWC. and IWD Description The ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD aging management program is part of the inservice inspection (ISI) program and provides for condition monitoring of reactor coolant pressure retaining piping and components within the scope of license renewal, except for the reactor pressure vessel. It also provides for condition monitoring of reactor internal components within the scope of license renewal, and the Dresden isolation condenser. The program is implemented through procedures that require examinations consistent with ASME Section XA and for Quad Cities an approved relief request PR-02.

The program includes:

Cracking monitoring for susceptible Inservice inspection Class I

components subject to a steam or reactor water environment, through volumetric examinations of pressure retaining welds and their heat affected zones in piping components.

Cracking monitoring of the Quad Cities reactor vessel flange leak detection line through monitoring for leaks during reactor vessel flood-up in accordance with relief request PR-02.

Loss of fracture toughness monitoring for susceptible inservice inspection Class 1 components in reactor recirculation and reactor water cleanup systems through visual inspections of reactor recirculation and reactor water cleanup valves and reactor recirculation pumps for signs of this aging effect.

Cracking monitoring for susceptible reactor internal components subject to a reactor water environment, through surface and volumetric examinations.

Cracking monitoring of the Dresden isolation condenser through surface and volumetric examinations of pressure retaining nozzle welds and their heat affected zones that are subject to a steam or reactor water environment.

Dresden and Quad Cities Page B-6 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Loss of material monitoring of portions of the Dresden isolation condenser subject to a steam or reactor water environment, through system pressure tests.

NUREG-1801 Consistency With enhancement the ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD aging management program is consistent with the ten elements of aging management program XI.M1, "ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that the aging of the isolation condenser is to be managed by ASME Section XI Inservice Inspection (ISI) Subsection IWB (for Class 1 components).

However, the Dresden isolation condenser is ISI Class 2 on the tube side and ISI Class 3 on the shell side. Therefore, Subsections IWC and IWD are used, as Class 1 requirements do not apply.

Enhancements NUREG-1801 indicates this program is to use the 1995 Edition through the 1996 Addenda of ASME Section XI.

The current Code of record for Dresden and Quad Cities is the 1989 Edition of ASME Section XI. The program will be revised to be consistent with the requirements of the 1995 Edition through the 1996 Addenda of ASME Section XI.

The enhancement is scheduled for implementation prior to the period of extended operation.

Operating Experience Dresden and Quad Cities have both successfully identified indications of age-related degradation prior to the loss of the intended functions of the components, and have taken appropriate corrective actions through evaluation, repair or replacement of the components in accordance with ASME Section XI and station implementing procedures.

Conclusion The ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD aging management program provides reasonable assurance that aging effects are adequately managed so that the intended functions of components within the scope of license renewal that are covered by this program are maintained during the period of extended operation.

Dresden and Quad Cities Page B-7 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.2 Water Chemistry Description The water chemistry aging management program activities consist of measures that are used to manage aging of components exposed to reactor water, condensate and feedwater, control rod drive water, demineralized water storage tank water, condensate tank water, torus water (pressure suppression pool), and spent fuel pool water. The program activities provide for monitoring and controlling of water chemistry using station procedures and processes based on EPRI TR-103515, "BWR Water Chemistry Guidelines," 2000 Revision for the prevention or mitigation of loss of material and cracking aging effects.

Control of water chemistry does not preclude loss of material due to general, crevice or pitting corrosion at locations of stagnant flow. The One-Time Inspection (B.1.23) aging management program includes provisions specified by NUREG-1801 for verification of chemistry control and confirmation of the absence of loss of material in stagnant flow areas in piping systems and components.

NUREG-1801 Consistency With enhancements the water chemistry aging management program is consistent with the ten elements of aging management program XI.M2, "Water Chemistry," specified in NUREG-1 801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that water chemistry control is in accordance with BWRVIP-29 for water chemistry in BWRs.

BWRVIP-29 references the 1993 revision of EPRI TR-103515, "BWR Water Chemistry Guidelines." The Dresden and Quad Cities water chemistry programs are based on EPRI TR-103515-R2, which is the 2000 Revision of "BWR Water Chemistry Guidelines."

EPRI periodically updates the water chemistry guidelines, as new information becomes available. EPRI TR-103515-R2 incorporates new information to develop proactive plant-specific water chemistry programs to minimize IGSCC.

NUREG-1801 indicates that hydrogen peroxide is monitored to mitigate degradation of structural materials.

The Dresden and Quad Cities programs do not monitor for hydrogen peroxide because the rapid decomposition of hydrogen peroxide makes reliable data exceptionally difficult to obtain and EPRI TR-103515 Section 4.3.3, 'Water Chemistry Guidelines for Power Operation," does not address monitoring for hydrogen peroxide.

NUREG-1801 indicates that dissolved oxygen is monitored.

Consistent with the guidance provided in EPRI TR-103515, condensate storage tank, demineralized water storage tank water and torus (pressure suppression pool) water is not sampled for dissolved oxygen.

Dresden and Quad Cities Page B-8 Ucense Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS NUREG-1801 indicates that water quality (pH and conductivity) is maintained in accordance with established guidance.

However, per EPRI TR-103515-R2, "BWR Water Chemistry Guidelines," Section 5.2.1.11, pH measurement accuracy in most BWR streams is generally suspect because of the dependence of the instrument reading on ionic strength of the sample solution. In addition, the monitoring of pH is not discussed in EPRI TR-103515-R2, Appendix B for condensate storage tank, demineralized water storage tank, or torus (pressure suppression pool) water. Therefore, pH is not monitored in condensate storage tank, demineralized water storage tank, or torus (pressure suppression pool) water.

Aging of SBLC system components not in the reactor coolant pressure boundary section of SBLC system relies on monitoring and control of SBLC makeup water chemistry. The makeup water is monitored In lieu of the storage tank, because the sodium pentaborate that is maintained in the storage tank would mask most of the chemistry parameters monitored. The effectiveness of the water chemistry program will be verified by a one time VT-3 inspection of a Dresden SBLC pump discharge valve casing and a Quad Cities SBLC pump casing as discussed in the One-Time Inspection (B.1.23) aging management program.

Enhancements

"* Procedures will be revised to provide for increased sampling to verify corrective actions taken to address abnormal chemistry conditions.

"* The Quad Cities procedure for turbine building sample panel collection will be revised to assure maintenance of the chemistry integrity of samples.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience Appropriate guidance for maintaining the contaminants below specific limits is provided.

Periodic self-assessments of the water chemistry activities have been and continue to be performed to identify areas that need improvement to maintain the quality performance of the activity, such as improved condensate demineralizer element precoating to minimize feedwater iron excursions.

The water chemistry program has identified instances where parameters were outside the established specifications. Increased sampling and actions to bring the parameters back into specification were initiated. Additionally, previous inspections of test coupons have demonstrated the effectiveness of the chemistry program applied to the spent fuel pool in managing the aging of aluminum and stainless steel in this environment.

Dresden and Quad Cities Page B-9 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The water chemistry aging management program covers components within the scope of license renewal that are exposed to reactor water, condensate, feedwater, control rod drive water, condensate tank water, torus water, and spent fuel pool water.

The program when supplemented with one-time inspections as required by NUREG-1801 provides reasonable assurance that components in the scope of license renewal are maintained in their desired environment during the period of extended operation, which mitigates the aging effects of loss of material and cracking.

Dresden and Quad Cities Page B-10 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.3 Reactor Head Closure Studs Description The reactor head closure studs aging management program provides for condition monitoring and preventive activities to manage stud cracking and loss of material. The program is implemented through station procedures based on the examination and inspection requirements specified in ASME Section XI, Table IWB-2500-1 and preventive measures described in Regulatory Guide 1.65, "Materials and Inspection for Reactor Vessel Closure Studs." The reactor head studs at Dresden and Quad Cities are not metal-plated, and have had manganese phosphate coatings applied.

NUREG-1801 Consistency With enhancement the reactor head closure studs aging management program is consistent with the ten elements of aging management program XI.M3, "Reactor Head Closure Studs," specified in NUREG-1 801 With the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that program inspections are in accordance with the requirements of ASME Section XI, Subsection IWB, Table IWB 2500-1. The Dresden and Quad Cities programs utilize relief requests CR-13 and CR-11 respectively. These relief requests provide for a VT-1 visual inspection instead of a surface examination of reactor closure head nuts.

NUREG-1801 indicates that the reactor closure head studs receive volumetric examinations. Quad Cities reactor closure head studs are examined by end shot UT as approved in relief request CR-12.

Enhancements NUREG-1801 indicates this programis to use the 1995 Edition through the 1996 Addenda of ASME Section XI. The current Code of record for Dresden and Quad Cities is the 1989 Edition of ASME Section XI. The program will be revised to be consistent with the requirements of the 1995 Edition through the 1996 Addenda of ASME Section XI.

The enhancement is scheduled for implementation prior to the period of extended operation.

Dresden and Quad Cities Page B-11 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Operating Experience The Dresden and Quad Cities inspection and testing methodologies have detected aging effects (cracking) prior to loss of their intended functions. Engineering evaluations have resulted in various specific component and programmatic corrective actions.

The reactor head closure studs aging management program activities have detected aging degradation and implemented appropriate corrective actions to maintain system and component intended functions including prompt repair or replacement of degraded components prior to failure.

Conclusion The reactor head closure studs aging management program provides reasonable assurance that loss of material and cracking aging effects are adequately managed so that the intended functions of components within the scope of license are maintained during the period of extended operation.

Dresden and Quad Cities Page B-12 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.4 BWR Vessel ID Attachment Welds Description The BWR vessel ID attachment welds aging management program activities incorporate the inspection and evaluation recommendations of BWRVIP-48, WVessel ID Attachment Weld Inspection and Evaluation Guidelines,'

as well as the water chemistry recommendations of EPRI TR-103515-R2, *BWR Water Chemistry Guidelines." The program is implemented through station procedures that provide for mitigation of cracking through water chemistry and monitoring for cracking through invessel examinations. Reactor vessel attachment weld inspections are implemented through station procedures that are part of inservice inspection and incorporate the requirements of ASME Section XI. The ASME inspections are enhanced with inspections consistent with BWRVIP-48.

NUREG-4S01 Consistency With enhancement, the BWR vessel ID attachment welds aging management program is consistent with the ten elements of aging management program XI.M4, "BWR Vessel ID Attachment Welds," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that water chemistry control is in accordance with BWRVIP-29, "BWR Water Chemistry Guidelines.' BWRVIP-29 references the 1993 revision of EPRI TR-103515, "BWR Water Chemistry Guidelines." The Dresden and Quad Cities water chemistry programs are based on EPRI TR-103515-R2, which is the 2000 revision.

Section B.1.2 presents the Water Chemistry aging management program and the exceptions to the program as specified in NUREG-1801.

Enhancements NUREG-1801 indicates this programis to use the 1995 Edition through the 1996 Addenda of ASME Section XI.

The current Code of record for Dresden and Quad Cities is the 1989 Edition of ASME Section Xl. The program will be revised to be consistent with the requirements of the 1995 Edition through the 1996 Addenda of ASME Section Xl.

This enhancement is scheduled for implementation prior to the period of extended operation.

Operating Experience The Dresden and Quad Cities inspection and testing methodologies have not detected cracking attachment welds. However, the same inspection and testing methodologies have detected cracking on the vessel internals. Section B.1.9 presents the BWR Vessel Internals aging management program.

Dresden and Quad Cities Page B-13 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The BWR vessel ID attachment welds aging management program provides reasonable assurance that cracking aging effects are adequately managed so that the intended functions of vessel ID attachment welds are maintained during the period of extended operation.

Dresden and Quad Cities Page B-14 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.5 BWR Feedwater Nozzle Description The BWR feedwater nozzle aging management program provides for monitoring of feedwater nozzles for cracking through station procedures based on ASME Section XA augmented by inspections performed in accordance with the inspection recommendations of General Electric NE-523-A71-0594, "Alternate BWR Feedwater Nozzle Inspection Requirements."

The program addresses the requirements of NUREG-0619, "BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking," by implementation of General Electric NE-523-A71-0594.

The Dresden and Quad Cities feedwater nozzles have been modified to mitigate cracking by removing the stainless steel cladding.

NUREG-1801 Consistency The BWR feedwater nozzle aging management program is consistent with the ten elements of aging management program XLIM5, "BWR Feedwater Nozzle," specified in NUREG-1801.

Operating Experience The Dresden and Quad Cities inspection and testing methodologies have detected indications of cracking aging effects on feedwater nozzles prior to loss of their intended functions.

These indications were evaluated by engineering and the cracks were repaired by grinding and re-examination or the sleeve was replaced as determined by the engineering evaluation, ASME Code, and station procedures.

Conclusion The BWR feedwater nozzle aging management program provides reasonable assurance that the aging effects of cracking are adequately managed so that the intended functions of the feedwater nozzles are maintained during the period of extended operation.

Dresden and Quad Cities Page B-15 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.6 BWR Control Rod Drive Return Line Nozzle Description The control rod drive return line nozzle aging management program consists of inservice inspections and previously implemented system modifications to manage the aging effect of cracking in the control rod drive return line nozzles. Dresden and Quad Cities have capped the control rod drive return line nozzles.

Inservice inspections are performed consistent with ASME Section XI requirements. No augmented inspections are required.

NUREG-1801 Consistency With enhancement the control rod drive return line nozzle aging management program is consistent with the ten elements of aging management program XI.M6, "BWR Control Rod Drive Return Line Nozzle," specified in NUREG-1 801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that the program includes system modifications and enhanced inservice inspections. The Dresden and Quad Cities programs do not provide for the augmented inspections specified in NUREG-0619, 5BWR Feedwater Nozzle and Control Rod Drive Return Line Nozzle Cracking," because the control rod drive return line nozzles have been capped. Inservice inspections are performed consistent with ASME Section XI requirements.

Enhancements NUREG-1801 indicates this program is to use the 1995 Edition through the 1996 Addenda of ASME Section XI.

The current Code of record for Dresden and Quad Cities is the 1989 Edition of ASME Section XI. The program will be revised to be consistent with the requirements of the 1995 Edition through the 1996 Addenda of ASME Section XI.

The enhancement is scheduled for implementation prior to the period of extended operation.

Operating Experience The Dresden and Quad Cities inspection and testing methodologies have detected indication of cracking aging effects on control rod drive nozzles prior to loss of their intended functions. These indications were repaired by flaw removal or weld overlay as determined appropriate by engineering evaluation in accordance with ASME Code and station procedure requirements.

Dresden and Quad Cities Page B-16 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The control rod drive return line nozzle aging management program provides reasonable assurance that the aging effects of cracking are adequately managed so that the intended functions of control rod return line nozzles are maintained during the period of extended operation.

Dresden and Quad Cities Page B-17 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.7 BWR Stress Corrosion Cracking Description BWR stress corrosion cracking aging management program mitigates intergranular stress corrosion cracking (IGSCC) in stainless steel reactor coolant pressure boundary components and piping four inches and greater nominal pipe size. Preventive measures include monitoring and controlling of water impurities by water chemistry program activities and providing replacement stainless steel components in the solution annealed condition with a maximum carbon content of 0.035 wt. % and a minimum ferrite level of 7.5 wt. %. Inspection and flaw evaluation are conducted in accordance with the inservice inspection program plan for the station.

The program is implemented through station procedures based on NUREG-0313, "Technical Report on Material Selection and Processing Guidelines for BWR Coolant Pressure Boundary Piping," GL 88-01, "NRC Position on Intergranular Stress Corrosion Cracking (IGSCC) in BWR Austenitic Stainless Steel Piping,* and its Supplement 1, BWRVIP-75, 'Technical Basis for Revisions to Generic Letter 88-01 Inspection Schedules,' EPRI TR-103515-R2, TBWR Water Chemistry Guidelines," and ASME Section XI.

NUREG-1801 Consistency With enhancement the BWR stress corrosion cracking aging management program is consistent with the ten elements of aging management program XI.M7, "BWR Stress Corrosion Cracking," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that water chemistry control is in accordance with BWRVIP-29 for water chemistry in BWRs. BWRVIP-29 references the 1993 revision of EPRI TR 103515, "BWR Water Chemistry Guidelines." The Dresden and Quad Cities water chemistry programs are based on EPRI TR-103515-R2, which is the 2000 revision.

Section B.1.2 presents the Water Chemistry aging management program and the exceptions to the program as specified in NUREG-1801.

Enhancements NUREG-1801 indicates this program is to use the 1995 Edition through the 1996 Addenda of ASME Section XI.

The current Code of record for Dresden and Quad Cities is the 1989 Edition of ASME Section XI. The program will be revised to be consistent with the requirements of the 1995 Edition through the 1996 Addenda of ASME Section XI.

The enhancement is scheduled for implementation prior to the period of extended operation.

Dresden and Quad Cities PageB-18 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Operating Experience BWR stress corrosion cracking aging management program activities have detected flaw indications in reactor coolant pressure boundary piping prior to loss of intended functions of the components, such as indications on the reactor vessel safe ends, and IGSCC on recirculation piping.

These indications were evaluated by engineering, and where necessary were repaired in accordance with ASME Section XI and station procedural requirements. Periodic self-assessments of program activities have been performed and will continue to be performed to identify areas that need improvement. When problems have been identified corrective actions have been taken to prevent recurrence.

Conclusion The BWR stress corrosion cracking aging management program provides reasonable assurance that IGSCC aging effects are adequately managed so that the intended functions of the stainless steel components in the reactor coolant pressure boundary are maintained during the period of extended operation.

Dresden and Quad Cities Page B-19 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.8 BWR Penetrations Description The BWR penetrations aging management program activities incorporate the inspection and evaluation recommendations of BWRVIP-27, "BWR Standby Liquid Control System/Core Plate Delta-P Inspection and Flaw Evaluation Guidelines,* and BWRVIP-49, Instrument Penetration Inspection and Flaw Evaluation Guidelines,' as well as the water chemistry recommendations of EPRI TR-103515-R2, "BWR Water Chemistry Guidelines.' The program is implemented through station procedures that provide for mitigation of cracking through the water chemistry and monitoring for cracking through inservice inspection examinations.

Penetration inspections are implemented through station procedures that are part of inservice inspection and incorporate the requirements of ASME Section XI.

NUREG-1801 Consistency With enhancement the BWR penetrations aging management program is consistent with the ten elements of aging management program XI.M8, "BWR Penetrations," specified in NUREG-1 801 with the following exceptions.

Exceptions to NUREG-4801 NUREG-1801 indicates that water chemistry control is in accordance with BWRVIP-29 for water chemistry in BWRs.

BWRVIP-29 references the 1993 revision of EPRI TR-103515, "BWR Water Chemistry Guidelines." The Dresden and Quad Cities water chemistry programs are based on EPRI TR-103515-R2, which is the 2000 revision.

Section B.1.2 presents the Water Chemistry aging management program and the exceptions to the program as specified in NUREG-1801.

NUREG-1801 indicates that the standby liquid control system nozzles are inspected in accordance with the requirements of ASME Section XI, Subsection IWB. The Dresden and Quad Cities programs utilize relief request ISI CR-01 that provides for inspection of the inner radius of the standby liquid control system nozzle by a VT-2 examination instead of the normal volumetric inspection required by the ASME Code.

Enhancements NUREG-1801 indicates this program Is to use the 1995 Edition through the 1996 Addenda of ASME Section XI. The current Code of record for Dresden and Quad Cities is the 1989 Edition of ASME Section XI. The program will be revised to be consistent with the requirements of the 1995 Edition through the 1996 Addenda of ASME Section XI.

The enhancement is scheduled for implementation prior to the period of extended operation.

Dresden and Quad Cities Page B-20 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Operating Experience The Dresden and Quad Cities inspection and testing methodologies have detected cracking aging effects prior to loss of their intended functions. Engineering evaluations have resulted in various specific component and programmatic corrective actions. No instrument penetration or standby liquid control nozzle indications have been reported.

These penetrations are covered by the same inspection procedure as used for vessel internals inservice inspection. Section B.1.9 presents the BWR Vessel Internals aging management program.

Conclusion The BWR penetrations aging management program provides reasonable assurance that the aging effects of cracking are adequately managed so that the intended functions of instrument penetrations and the standby liquid control system nozzles are maintained during the period of extended operation.

Dresden and Quad Cities Page B-21 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.9 BWR Vessel Internals Description The BWR vessel internals aging management program mitigates the effects of SCC, IGSCC, and IASCC in reactor pressure vessel internals through water chemistry activities that are implemented through station procedures and are consistent with the guidelines of EPRI TR-103515-R2, "BWR Water Chemistry Guidelines," 2000 Revision.

The program also manages cracking of reactor pressure vessel internals through condition monitoring activities that consist of examinations implemented through station procedures consistent with the recommendations of the BWRVIP guidelines, as well as the requirements of ASME Section XI.

NUREG-1801 Consistency With enhancement the BWR vessel internals aging management program is consistent with the ten elements of aging management program XI.M9, "BWR Vessel Internals,"

specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that water chemistry control is in accordance with BWRVIP-29, "BWR Water Chemistry Guidelines.

BWRVIP-29 references the 1993 revision of EPRI TR-103515, "BWR Water Chemistry Guidelines." The Dresden and Quad Cities water chemistry programs are based on EPRI TR-103515-R2, which is the 2000 revision.

Section B.1.2 presents the Water Chemistry aging management program and the exceptions to the program as specified in NUREG-1801.

Enhancements NUREG-1801 indicates this program is to use the 1995 Edition through the 1996 Addenda of ASME Section XI.

The current Code of record for Dresden and Quad Cities is the 1989 Edition of ASME Section XI. The program will be revised to be consistent with the requirements of the 1995 Edition through the 1996 Addenda of ASME Section XI.

The enhancement is scheduled for implementation prior to the period of extended operation.

Operating Experience BWR vessel internals aging management activities have detected aging degradation and implemented appropriate corrective actions to maintain system and component intended functions including prompt repair of degraded components prior to failure. This includes cracking adjacent to the Quad Cities access hole cover and cracking of the reactor internal portion of the core spray piping at Dresden Unit 3.

After evaluation by engineering, these cracks were repaired in accordance with ASME Section XI and station procedure requirements.

Jet Pump Beam Assembly #20 failed at Quad Cities Unit 1 in January 2002. All similar beams have been replaced with improved heat treatment beams.

Dresden and Quad Cities Page B-22 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The BWR vessel internals aging management program provides reasonable assurance that stress corrosion cracking, intergranular stress corrosion cracking, and irradiation assisted stress corrosion cracking aging effects are adequately managed so that the intended functions of BWR vessel internals within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-23 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.10 Thermal Aging and Neutron Irradiation Embrittlement of Cast Austenitic Stainless Steel (CASS)

Description The aging management program for thermal aging and neutron irradiation embrittlement of cast austenitic stainless steel (CASS) is a new program that provides for aging management of CASS reactor internal components within the scope of license renewal.

The program is scheduled for implementation prior to the period of extended operation.

The program will include a component specific evaluation of the loss of fracture toughness. For those components where loss of fracture toughness may affect function of the component, an inspection will be performed as part of the station ISI program.

This inspection will ensure the integrity of the CASS components exposed to the high temperature and neutron fluence present in the reactor environment NUREG-1801 Consistency With enhancement the aging management program for thermal aging and neutron irradiation embrittlement of cast austenitic stainless steel (CASS) will be consistent with the ten elements of aging management program XI.M13, "Thermal Aging and Neutron Irradiation Embrittlement of Cast Austenitic Stainless Steel (CASS)," specified in NUREG-1801.

Enhancements The aging management program for thermal aging and neutron irradiation embrittlement of cast austenitic stainless steel (CASS) is a new program, and therefore, the entire program is an enhancement.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience The aging management program for thermal aging and neutron irradiation embrittlement of cast austenitic stainless steel (CASS) is a new program, and therefore, no operating experience exists.

Conclusion The aging management program provides reasonable assurance that thermal aging and neutron irradiation embrittlement aging effects are adequately managed so that the intended functions of cast austenitic stainless steel (CASS) components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-24 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.11 Flow-Accelerated Corrosion Description The flow-accelerated corrosion (FAC) aging management program is based on EPRI guidelines in NSAC-202L-R2, "Recommendations for an Effective Flow Accelerated Corrosion Program.'

The program predicts, detects, and monitors wall thinning in piping, fittings and valve bodies due to FAC.

Analytical evaluations and periodic examinations of locations that are most susceptible to wall thinning due to FAC are used to predict the amount of wall thinning in pipes and fittings. Program actMties include analyses to determine critical locations, baseline inspections to determine the extent of thinning at these critical locations, and follow-up inspections to confirm the predictions.

Repairs and replacements are performed as necessary.

NUREG-1801 Consistency With enhancement the flow-accelerated corrosion aging management program is consistent with the ten elements of aging management program XI.M17, "Flow Accelerated Corrosion," specified in NUREG-1801.

Enhancements NUREG-1801 indicates the FAC program is to be applied to the main steam piping within the scope of license renewal. The Dresden and Quad Cities FAC program will be expanded to include main steam piping within the scope of license renewal.

This enhancement is scheduled for implementation prior to the period of extended operation.

Operating Experience Operating experience of flow-accelerated corrosion aging management program activities has shown that the program can determine susceptible locations for flow accelerated corrosion, predict the component degradation, and detect the wall thinning in piping and valves due to flow-accelerated corrosion. In addition, the program provides for reevaluation, repair or replacement for locations where calculations indicate an area will reach minimum allowable thickness before the next inspection.

Periodic self assessments of the program have been performed which have identified opportunities for program improvements.

Improvements made as a result of the self-assessments include the addition of small bore HPCI turbine inlet drain lines to the program at Quad Cities.

Dresden and Quad Cities Page B-25 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The flow-accelerated corrosion (FAC) aging management program provides reasonable assurance that wall thinning aging effects are adequately managed so that the intended functions of components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-26 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.12 Bolting Integrity Description The bolting integrity aging management program provides for condition monitoring of selected pressure retaining bolted joints and external surfaces for piping and components within the scope of license renewal.

The bolting integrity program incorporates industry recommendations addressed in EPRI NP-5769, "Degradation and Failure of Bolting in Nuclear Power Plants," as part of the comprehensive corporate component pressure retaining bolting program.

The program consists of visual inspections for external surface degradation that may be caused by loss of material or cracking of the bolting, or by an adverse environment. The activities are implemented through station procedures and predefined tasks. Inspection of inservice inspection Class 1, 2 and 3 components is conducted in accordance with ASME Section XI. Non safety component inspections rely on detection of visible leakage during preventive maintenance and routine observation activities.

NUREG-1801 Consistency With enhancements the bolting integrity aging management program is consistent with the ten elements of aging management program XI.M18, "Bolting Integrity," specified in NUREG-1 801 with the following exceptions.

Exceptions to NUREG-1 801 NUREG-1801 indicates that EPRI TR-104213, "Bolted Joint Maintenance and Applications Guide," is used as a basis for evaluation of the structural integrity of non safety related bolting. NUREG-1801 also indicates that the bolting integrity programs developed and implemented in accordance with commitments made in response to NRC communications on bolting events have provided an effective means of ensuring bolting reliability.

These programs are documented in EPRI NP-5769 and TR-104213 and represent industry consensus. The Dresden and Quad Cities programs address the guidance contained in EPRI TR-1 04213 but do not specifically cite its use.

NUREG-1801 indicates that the program covers all bolting within the scope of license renewal including structural bolting. The Dresden and Quad Cities bolting integrity programs do not address structural bolting. The Structures Monitoring Program (B. 1.30) covers aging management of structural bolting.

NUREG-1801 indicates that the program covers all bolting within the scope of license renewal including bolting for Class I NSSS component supports. The Dresden and Quad Cities bolting integrity programs do not address Class I NSSS component support bolts. Aging management of ASME Section XA Class 1, 2, and 3, and Class MC support members, including mechanical connections, is covered by the ASME Section XI, Subsection IWF (B.1.27) aging management program.

NUREG-1801 indicates that the program generally Includes periodic inspection for loss of preload. The Dresden and Quad Cities programs do not include inspections for loss Dresden and Quad Cities Page B-27 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS of preload because loss of preload in a mechanical joint is a design driven effect and not an aging effect.

Enhancements The program will be revised as necessary to be in accordance with the 1995 Edition through the 1996 Addenda, and approved relief requests instead of the 1989 Edition with approved relief requests, of ASME Section XI for inspection of inservice inspection Class 1, 2 and 3 components.

"* The program will provide for formal inspections of bolted joints of diesel generator system components and performing periodic component bolted joint inspections in high-humidity/moisture areas (pump vaults).

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience Dresden and Quad Cities have experienced isolated cases of bolting degradation attributed to loss of material and cracking aging effects. No reactor coolant pressure boundary leakage due to boric acid induced degradation has been noted since both stations are BWRs. System engineer walkdowns have also identified incidental surface rust on exterior component surfaces. In all cases, the existing inspection and testing methodologies have discovered the deficiencies and corrective actions were implemented prior to loss of system or component intended functions.

Conclusion The bolting integrity aging management program provides reasonable assurance that loss of material and cracking aging effects are adequately managed so that the intended functions of bolting for pressure retaining joints and external surfaces for piping and components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-28 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.13 Open-Cycle Cooling Water System Description The open-cycle cooling water (OCCW) system aging management program primarily consists of station GL 89-13, "Service Water System Problems Affecting Safety-Related Equipment,' programs that include system test procedures, system inservice testing procedures, periodic component inspections and piping nondestructive examinations (NDE). Other program activities include station maintenance inspections, component preventive maintenance (PM) testing and inservice inspection (ISI) procedures and inspections for the Class 3 portions of raw water systems in the scope of license renewal.

The OCCW aging management program activities provide for management of loss of material, cracking, buildup of deposits and flow blockage aging effects in cooling water systems that are tested and inspected in accordance with guidelines of GL 89-13. The program also provides for managing loss of material aging degradation on the outside surfaces of cooling water and ultimate heat sink (UHS) components in the scope of license renewal by condition monitoring of the accessible extemal surfaces of components in moist air (indoor) or submerged (raw water) environments.

The OCCW aging management program activities apply to raw cooling water system piping and components and include both condition monitoring and mitigating actions for managing loss of material, cracking and flow blockage aging effects. System and component tests, visual Inspections, NDE, flushing, and chemical treatment are conducted to ensure that aging effects are managed such that system and component functions are maintained.

The station maintenance and PM procedures provide for condition monitoring of raw water components within the scope of license renewal. ISI procedures for the inservice inspection of the Class 3 portions of raw water systems provide for periodic leakage detection of the aboveground and buried piping and components and inspection of the aboveground piping and components.

Extemal surfaces of buried cooling water and UHS components are not included in this program because they are included in the Buried Piping and Tanks Inspection (B.1.25) aging management program.

NUREG-1801 Consistency With enhancements the open-cycle cooling water system aging management program is consistent with the ten elements of aging management program XI.M20, "Open-Cycle Cooling Water System," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that program testing and inspections are performed annually and during refueling outages. The Dresden and Quad Cities open-cycle cooling water system aging management program activities provide for adjustment of inspection intervals due to specific inspection results as stated in the response to GL 89-13.

Dresden and Quad Cities Page B-29 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Enhancements

"* The program will provide for inspection of cooling water pump internal linings, additional heat exchangers and sub-components, inspection of external surfaces of various submerged pumps and piping.

"* The program will provide for new periodic component inspections in the pump vaults that have a high humidity/moisture environment.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience The open-cycle cooling water system aging management activities have detected aging degradation and implemented appropriate corrective actions to maintain system and component intended functions including prompt repair of degraded components prior to failure.

Prior to the implementation of the station GL 89-13 program activities, component blockage was a recurring problem resulting in valves being unable to function. More recent periodic system flushing and component inspections and cleaning have detected minor levels of biofouling and silting, primarily in system drain lines, that was removed without any loss of system functions. Component external surfaces have experienced corrosion, primarily in the pump vaults.

Flooding and high humidity conditions noted in pump vaults contribute to creating a corrosive external environment.

In all cases, the degradation was identified and corrective actions implemented prior to loss of system or component intended functions.

Engineering evaluations have resulted in various specific component and programmatic enhancements and corrective actions.

In addition, program assessments have been reviewed for heat sink performance.

Conclusion The open-cycle cooling water system aging management program provides reasonable assurance that loss of material, cracking, buildup of deposits and flow blockage aging effects are adequately managed so that the intended functions of open-cycle cooling water system components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-30 Ucense Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.14 Closed-Cycle Cooling Water System Description The closed-cycle cooling water system aging management program activities manage loss of material, cracking, and buildup of deposit aging effects in system components in the scope of license renewal exposed to closed-cycle cooling water environments. The program provides for preventive, performance monitoring and condition monitoring activities that are implemented through station procedures. Preventive activities include measures to maintain water purity and the addition of corrosion inhibitors to minimize corrosion based on EPRI TR-107396, "Closed Cooling Water Chemistry Guidelines."

Performance monitoring provides indications of degradation in closed-cycle cooling water systems, with plant operating conditions providing indications of degradation In normally operating systems.

In addition, station maintenance inspections and NDE provide condition monitoring of heat exchangers exposed to closed-cycle cooling water environments.

Heat exchanger activities are based on EPRI Report 1003056, "Non Class 1 Mechanical Implementation Guideline and Mechanical Tools," Revision 3, November 2001, Appendix G, "Heat Exchangers,"

Sandia National Laboratory Report SAND 93-7070 UC-523, "Aging Management Guideline for Commercial Nuclear Power Plants - Heat Exchangers," and ASME OM-S/G-2000, Part 21, "Inservice Performance Testing of Heat Exchangers In Light-Water Reactor Power Plants."

NUREG-1801 Consistency With enhancements the closed-cycle cooling water system aging management program is consistent with the ten elements of aging management program XI.M21, "Closed Cycle Cooling Water System," specified in NUREG-1 801.

Enhancements Procedure revisions will provide for monitoring of specific parameters in accordance with EPRI TR-107396 guidance.

Procedure revisions include provisions for monitoring parameters such as pH, specific gravity, freeze point, reserve alkalinity, percent glycol and suspended solids In glycol based systems.

"* Dresden procedure revisions will provide for monitoring pH and ammonia in the diesel generator jacket water.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience The Dresden and Quad Cities stations have not experienced a loss of intended function failure of components due to corrosion product buildup or through-wall cracking for components within the scope of license renewal that are subject to closed-cycle cooling water system activities. Additionally, industry operating experience demonstrates that the use of corrosion inhibitors in closed-cycle cooling water systems that are monitored Dresden and Quad Cities Page B-31 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS and maintained is effective in mitigating loss of material, cracking, and buildup of deposits.

The Dresden and Quad Cities closed-cycle cooling water system activities have detected loss of material, cracking, and buildup of deposit aging effects in heat exchangers prior to loss of system intended functions. Engineering evaluations have resulted in various specific component and programmatic corrective actions.

Conclusion The closed-cycle cooling water system aging management program provides reasonable assurance that loss of material, cracking, and buildup of deposits aging effects are adequately managed so that the intended functions of components exposed to closed cycle cooling water environments within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-32 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.15 Inspection of Overhead Heavy Load and Lilht Load (Related to Refueling) Handling Systems Description This aging management program provides for visual inspections of overhead heavy load and light load (related to refueling) handling systems.

The program, which is implemented through station procedures, manages loss of material of bridge and trolley structural components for systems within the scope of 10 CFR 54.4 and other load handling systems within the scope of license renewal.

NUREG-1801 Consistency With enhancements, the inspection of overhead heavy load and light load (related to refueling) handling systems aging management program is consistent with the ten elements of aging management program XI.M23, "Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that the number and magnitude of lifts made by the crane are reviewed. The Dresden and Quad Cities programs do not provide for tracking of the number and magnitude of lifts because administrative controls are implemented to ensure that only allowable loads are handled and fatigue failure of structural elements is not expected. A time-limited aging analysis concludes that there are no fatigue concerns for reactor building overhead cranes during the period of extended operation. Frequent inspections of cranes for indications of functional failures are conducted.

Enhancements

", The program will provide for specific inspections for rail wear and proper crane travel on rails.

"* The program will provide for specific inspections for corrosion of crane structural components.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience This program has been successful in managing aging of structural components of overhead heavy load and light load (related to refueling) handling systems so that intended functions have been maintained. The Dresden and Quad Cities corrective action process records indicate that crane operational problems have been minor and do not indicate that there has been degradation of structural components.

Dresden and Quad Cities Page B-33 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The inspection of overhead heavy load and light load (related to refueling) handling systems aging management program provides reasonable assurance that loss of material aging effects are adequately managed so that the Intended functions of crane structural components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-34 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.16 Compressed Air Monitoring Description The compressed air monitoring aging management program activities manage loss of material due to general, crevice, and pitting corrosion for portions of the instrument air system within the scope of license renewal. Program activities consist of air quality testing, pressure decay testing, and visual inspections at various system locations. The activities are consistent with Dresden and Quad Cities responses to NRC Generic Letter 88-14, "Instrument Air Supply Problems,* and ANSI/ISA-S7.3-1975, "Quality Standard for Instrument Air." Testing and monitoring activities are implemented through station specific procedures and associated predefined tasks.

NUREG-11801 Consistency With enhancements the compressed air monitoring aging management program is consistent with the ten elements of aging management program XI.M24, "Compressed Air Monitoring," specified in NUREG-1 801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that the program Is based on responses to GL 88-14 and INPO SOER 88-01, "Instrument Air System Failures,' as well as EPRI NP-7079-1990, EPRI TR-108147, "Compressor and Instrument Air System Maintenance Guide," ASME OM-S/G-1998 and ANSIfISA-S7.0.01-1996. *The Dresden and Quad Cities programs are based on the guidance provided in the GL 88-14 and ANSI/ISA-S7.3-1975 documents, which are part of the current licensing basis.

Enhancements include inspection of instrument air distribution piping based on EPRI TR-108147.

NUREG-1801 indicates that inservice inspection and testing Is performed to verify proper air quality, and confirm that maintenance practices, emergency procedures and training are adequate to ensure that the intended function of the air system is maintained. Inservice inspections at Dresden and Quad Cities do not verify air quality because air quality testing is performed in accordance with specific procedures based on ANSI/ISA-S7.3-1975. Maintenance practices, emergency procedures, and training are plant performance issues that are not directly related to aging management of the instrument air systems. Aging management consists of air quality tests and pressure decay tests of MSIV and safetylrelief valve pneumatic systems including accumulators, piping, and check valves, and periodic inspections to verify the integrity of the systems.

Enhancements

"* The program will provide for new periodic inspections for those portions of instrument air distribution piping at Dresden and Quad Cities that are within the scope of the rule.

"* The program will provide for periodic blowdowns of instrument air distribution piping at Dresden.

Dresden and Quad Cities Page B-35 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience Dresden has experienced recent occurrences of corrosion, corrosion product buildup, and dirt buildup in instrument air system piping, positioners, and valve operators. The program enhancement of providing periodic blowdowns of instrument air distribution piping addresses this condition.

Quad Cities has not experienced a failure of a pneumatic component within the scope of license renewal due to corrosion, corrosion product buildup, or dirt buildup since 1993.

The Quad Cities experience is consistent with the implementation of corrective actions in response to GL 88-14.

Dresden and Quad Cities have experienced equipment failures including MSIVs, dampers, and process valves due to instrument air leaks.

These failures were to individual components and did not propagate to other components within the system.

Dresden and Quad Cities have not experienced a common mode failure caused by the instrument air system. The Dresden and Quad Cities enhancements of performing predefined tasks that require periodic inspections of instrument air distribution piping address this condition.

Conclusion The compressed air monitoring aging management program provides reasonable assurance that loss of material aging effects are adequately managed so that the intended functions of the instrument air components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-36 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.11.17 BWR Reactor Water Cleanup System Description The aging management program for the BWR reactor water cleanup system provides for reactor water chemistry activities that reduce susceptibility to stress corrosion cracking (SCC) and intergranular stress corrosion cracking (IGSCC).

Dresden and Quad Cities have satisfactorily completed all actions requested in NRC GL 89-10, "Safety-Related Motor-Operated Valve Testing and Surveillance," and have replaced the reactor water cleanup (RWCU) system piping with piping that is resistant to intergranular stress corrosion cracking in accordance with NRC GL 88-01, "NRC Position on Intergranular Stress Corrosion Cracking (IGSCC) in BWR Austenitic Stainless Steel Piping. Therefore, inspection of RWCU piping is not required.

The reactor water chemistry activities provide for monitoring and controlling of water chemistry using station procedures and processes based on EPRI TR-103515, "BWR Water Chemistry Guidelines," 2000 Revision to reduce susceptibility of RWCU piping to SCC and IGSCC.

NUREG-1801 Consistency The BWR reactor water cleanup system aging management program is consistent with the ten elements of aging management program XI.M25, "BWR Reactor Water Cleanup System," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that water chemistry control is in accordance with BWRVIP-29, "BWR Water Chemistry Guidelines." BWRVIP-29 references the 1993 revision of EPRI TR-103515, "BWR Water Chemistry Guidelines." The Dresden and Quad Cities water chemistry programs are based on EPRI TR-103515-R2, which is the 2000 revision.

Section B.1.2 presents the Water Chemistry aging management program and the exceptions to the program as specified in NUREG-1 801.

Operating Experience Dresden and Quad Cities have replaced the reactor water cleanup (RWCU) system piping with piping that is resistant to intergranular stress corrosion cracking. No adverse trends have been detected In the chemistry program.

Conclusion The BWR reactor water cleanup system aging management program provides reasonable assurance that the SSC and IGSCC aging effects are adequately managed so that the intended functions of RWCU components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-37 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.18 Fire Protection Description The fire protection program provides for aging management of various fire protection related components within the scope of license renewal.

The program provides for visual inspection of fire barrier walls, ceilings and floors in structures within the scope of license renewal for the aging effects of cracking, spalling, and loss of material. The inspections are implemented through procedures that are part of the structures monitoring program.

The program provides for visual inspections of fire barrier penetration seals, fire wraps, and flood barrier penetration seals that also serve as fire barrier seals for signs of degradation, such as damage, holes, cracking, and loss of material, through periodic inspection, surveillance and maintenance activities. The inspections are implemented through station procedures. Flood barrier penetration seal inspections are part of the structures monitoring program.

The program provides or will provide for periodic visual inspections of fire doors for holes in skin, wear, or missing parts.

Fire door clearances are checked during periodic inspections and when fire doors and components are repaired or replaced.

Additionally, periodic functional tests of fire doors and periodic visual inspections for loss of barrier integrity of curb oil spill barriers are implemented through station procedures.

The program will provide for aging management of external surfaces of Dresden and Quad Cities carbon dioxide system components and Dresden halon system components for corrosion through periodic operability tests based on NFPA codes and visual inspections. Testing and inspections are implemented through predefined tasks and procedures.

The program will provide for managing loss of material aging effects for the fuel oil systems for the Dresden and Quad Cities diesel-driven fire pumps and the Dresden isolation condenser makeup pumps by the performance of periodic fuel oil system surveillance tests that are implemented through station procedures.

The Dresden isolation condenser diesel-driven makeup pumps are similar in design and function to the diesel-driven fire pumps. Therefore, the fuel oil systems for the isolation condenser makeup pumps are included in the program.

NUREG-1801 Consistency With enhancements the fire protection program is consistent with the ten elements of aging management program XI.M26, "Fire Protection," specified In NUREG-1801 with the following exceptions.

Dresden and Quad Cities Page B-38 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Exceptions to NUREG-1801 NUREG-1801 indicates that visual inspections performed at least once every refueling outage detect any sign of degradation of the concrete fire barrier walls, ceilings, and floors before there is a loss of the intended function. The Dresden and Quad Cities program requires inspection of concrete fire barriers once every five years. Station fire protection program inspections and other similar station inspections have not found any significant aging effect that required extensive corrective action for any concrete structure within the scope of license renewal. Typically, concrete cracks that have been observed have been attributed to normal concrete shrinkage occurring during construction and are non-active. Additionally, the environment surrounding Dresden and Quad Cities is non-aggressive for concrete, and industry guidance contained in ACI 349.3R-96, "Evaluation of Existing Nuclear Safety-Related Concrete Structures,"

indicates that a five-year inspection frequency for concrete components is adequate for timely identification and correction of degraded conditions prior to loss of intended function.

NUREG-1801 indicates that VT-1 or equivalent seal inspections and VT-3 or equivalent fire door inspections are performed. Personnel performing seal and fire door inspections at Dresden and Quad Cities are not qualified to American Society for Nondestructive Testing requirements. However, personnel performing these inspections are trained and experienced in fire protection program requirements, and the quality of the fire barrier penetration seal and fire door inspections are equivalent to the VT-1 and VT-3 inspections as is evidenced by the history of identifying conditions requiring maintenance, repair or replacement.

NUREG-1801 indicates that fire doors are visually inspected at least once bi-monthly for holes in the skin of the door. Fire door clearances are also checked at least once bi monthly as part of an inspection program. Function tests of fire doors are performed daily, weekly, or monthly to verify the operability of automatic hold-open, release, closing mechanisms, and latches. The Dresden and Quad Cities programs provide for an in depth inspection for condition and operability of fire doors once per operating cycle. The frequency of the in-depth inspections is appropriate because the fire doors most likely to experience excessive wear are those that are subject to the most frequent use, such as those in normal and high traffic areas, and such doors are monitored by normal plant operation during periodic fire marshal tours, operator rounds, and security patrols.

NUREG-1801 indicates that a periodic function test and visual Inspection performed at least once every six months detects degradation of the halon and carbon dioxide fire suppression systems before the loss of the component intended function. The Quad Cities and Dresden halon and carbon dioxide fire suppression systems are normally tested and inspected every 18 months. The Technical Requirements Manual permits a testing frequency of once every two years. This frequency is considered sufficient to ensure system availability and operability based on station operating history that indicates no occurrence of aging related events that have adversely affected system operation.

Dresden and Quad Cities Page B-39 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS NUREG-1801 indicates that any signs of corrosion and mechanical damage of the halon or carbon dioxide fire suppression system are not acceptable. The Dresden and Quad Cities programs require that signs of aging degradation on the external surfaces of the halon or carbon dioxide fire suppression systems are evaluated and corrective action is taken as required. This approach provides reasonable assurance that corrective actions appropriate to the observations will be implemented prior to loss of system or component intended functions.

NUREG-1801 indicates that the performance of the fire pump is monitored during the periodic test to detect any degradation in the fuel supply lines, and that periodic testing provides data (e.g., pressure) necessary for trending. The Dresden and Quad Cities diesel-driven fire pump test results and the Dresden isolation condenser diesel-driven makeup pump test results are not trended.

Instead, in the event the predetermined acceptance criteria are not met an engineering evaluation is conducted to determine the operability of the pump and the need for corrective action.

Enhancements

", The program will provide specific guidance at Dresden and Quad Cities to check fire doors for wear and holes in skin that could affect intended function during weekly tours.

The program will provide for inspection for corrosion on external surfaces of piping and components for the Dresden and Quad Cities carbon dioxide systems and the Dresden halon system.

"* The program will provide for performance of periodic capacity tests of the Dresden isolation condenser diesel-driven makeup pumps.

"* The program will provide specific guidance for examining the fire pump and the Dresden isolation condenser makeup pump diesel fuel supply systems for leaks during pump tests.

"* The program will provide for inspection of oil spill barriers for signs of damage that would break the integrity of the barrier at Quad Cities.

"* Dresden procedures will identify the frequency of inspections of fire doors and spill barriers.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience The fire protection program has been effective in identifying aging effects and taking appropriate corrective action.

Minor degradation such as minor cracks with water stains, pitting, and small amounts of leaching have been detected in concrete components in structures within the scope of license renewal including the Dresden reactor building and crib house, and the Quad Cities reactor building and circulating water intake bays. The observed degradation was Dresden and Quad Cities Page B-40 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS evaluated and dispositioned based on program acceptance criteria and in accordance with the corrective action process.

The Dresden and Quad Cities experience with fire barrier penetration seals is consistent with the industry experience. Silicone foam fire barrier penetration seals are used at Dresden. Silicone foam fire barrier penetration seals are not used at Quad Cites.

Dresden and Quad Cities have experienced fire door component degradation due to wear and physical damage. Mitigating actions have been taken as appropriate. No reports of door assembly loss of material due to corrosion have been identified for either station.

Dresden and Quad Cities operating experience has shown no loss of material on the external surfaces of components in the halon and carbon dioxide systems that have adversely affected system operation.

The Dresden and Quad Cities diesel-driven fire pump fuel oil systems have experienced minor system leakage events that have been detected and corrected in a timely manner.

In addition, Dresden reported high particulates in the Unit I fire pump fuel oil day tank, and Quad Cities reported a fuel oil separator drain line plugged with sediment. These were identified and corrected prior to loss of intended function of the fire pumps. There have been no reports of loss of material or flow blockage of the Dresden isolation condenser makeup pump fuel oil subsystem.

Conclusion The fire protection program covers various fire protection related components within the scope of license renewal including fire barrier doors, walls, ceilings, floors, penetration seals and wraps. It also covers flood barrier penetration seals, curb oil spill barriers, external surfaces of Dresden and Quad Cities carbon dioxide system components, and external surfaces of Dresden halon system components.

In addition, the program covers the fuel oil systems for Dresden and Quad Cities diesel-driven fire pumps and the Dresden isolation condenser makeup pumps.

The fire protection aging management program provides reasonable assurance that the cracking, spalling, loss of material and wear aging effects are adequately managed so that the intended functions of components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-41 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.19 Fire Water System Description The fire water system aging management program provides for managing loss of material and biofouling aging effects on intended functions of the water-based fire protection system components within the scope of license renewal through periodic inspection, surveillance testing, and maintenance activities.

Fire hose testing is not included in the program because fire hoses are consumables and not in the scope of license renewal.

Fire hoses are periodically inspected or tested and replaced as necessary in accordance with station procedures.

Inspection and surveillance is performed in accordance with procedures based on NFPA codes. Where code deviations are required or desirable, the intent of the code is maintained based on documented technical justifications.

NUREG-11801 Consistency With enhancements the fire water system aging management program is consistent with the ten elements of aging management program XI.M27, "Fire Water System," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that fire water systems are tested in accordance with NFPA codes and standards. The fire water systems at Dresden and Quad Cities used the NFPA codes as guidelines for their design. Similarly, inspection and periodic testing performed in accordance with corporate and station procedures were developed using NFPA codes as guidance. Where deviations are considered necessary or desirable, technical justifications are documented. Regardless of the codes of record, the credited inspections will be conducted at a frequency appropriate to detect aging degradation prior to loss of Intended function.

NUREG-1801 indicates that NRC GL 89-13, *Service Water System Problems Affecting Safety-Related Equipment,' recommends periodic flow testing of infrequently used loops of the fire water system at the maximum design flow to ensure that the system maintains its intended function. The Dresden and Quad Cities programs do not provide for flow tests at the maximum design flow and pressure because such tests are not practicable.

Periodic flow and pressure testing is performed to determine the condition of underground fire protection piping.

These tests measure hydraulic resistance and compare it with previous tests.

Enhancements

  • The program will provide for periodic non-intrusive wall thickness measurements of selected portions of the fire water system at intervals that do not exceed every 10 years.

Dresden and Quad Cities Page B-42 Ucense Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS

"* Pump bay inspection procedures will provide for external surface inspections for submerged fire pumps.

"* Fire hydrant test procedures will provide for external surface inspections for outdoor fire hydrants.

"* The requirement for external surface inspections of outdoor transformer deluge system components will be added to deluge system test procedures.

The program will provide for sampling of sprinklers in accordance with NFPA 25, "Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems,*

and submitting the samples to a testing laboratory prior to the sprinklers being in service 50 years. Subsequent testing is at intervals that do not exceed every 10 years.

Enhancements are scheduled for implementation at Dresden and Quad Cities prior to the period of extended operation.

Operating Experience Instances of fire water system degradation due to corrosion and biofouling have been detected at Dresden and Quad Cities. Some cases have resulted in system leakage or blockage that affected system capability. Problems have been identified and appropriate corrective actions were taken to prevent recurrence. Station activities and assessments have resulted in the following enhancements for aging management of biofouling: procedure revisions for more frequent pump bay cleaning to reduce silt and clam buildup; monitoring for zebra mussel infestation; and new periodic inspections of components susceptible to blockage (CY' strainers and check valves).

Conclusion The fire water system aging management program provides reasonable assurance that the loss of material and biofouling aging effects are adequately managed so that the intended functions of fire water components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-43 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.20 Aboveground Carbon Steel Tanks Description The aboveground carbon steel tanks aging management program provides for management of loss of material aging effects for outdoor carbon steel nitrogen storage tanks. The program provides for the application of paint as a corrosion preventive measure and for periodic visual inspections to monitor degradation of the paint and any resulting metal degradation.

The nitrogen storage tanks are aboveground and not directly supported by earthen or concrete foundations.

Therefore, inspection of the sealant or caulking at the tank foundation interface and inspection of inaccessible tank locations does not apply.

NUREG-1801 Consistency With enhancement the aboveground carbon steel tanks aging management program is consistent with the ten elements of aging management program XI.M29, "Aboveground Carbon Steel Tanks," specified in NUREG-1801.

Enhancements The program will provide for initiating documentation of inspection results of periodic system engineer walkdowns of the nitrogen storage tanks.

The enhancement is scheduled for implementation at Dresden and Quad Cities prior to the period of extended operation.

Operating Experience The Dresden and Quad Cities outdoor carbon steel nitrogen storage tanks have not experienced leakage or degradation due to loss of material.

Conclusion The aboveground carbon steel tanks aging management program provides reasonable assurance that the aging effects of loss of material are adequately managed so that the intended functions of outdoor nitrogen storage tanks within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-44 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.21 Fuel Oil Chemistry Description The fuel oil chemistry aging management program provides for preventive activities that manage the aging effects of loss of material and buildup of deposits in license renewal components that are exposed to fuel oil.

Program activities assure that contaminant levels are maintained at acceptable levels in fuel oil for systems within the scope of license renewal. A biocide is added to the fuel oil storage tanks during each new fuel delivery.

Fuel oil sampling and analysis are performed in accordance with procedures. Emergency diesel generator fuel oil analysis acceptance criteria are contained in the Technical Specifications and are based on the requirements of ASTM D975. Diesel fuel oil storage tanks are periodically cleaned and inspected for evidence of internal corrosion.

NUREG-1801 Consistency With enhancements, the fuel oil chemistry aging management program Is consistent with the ten elements of aging management program XI.M30, "Fuel Oil Chemistry," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-11801 NUREG-1801 discusses the need to mitigate corrosion of fuel oil storage tanks.

Corrosion mitigation activities are not performed for the Quad Cities Unit I underground fuel oil storage tank because it is constructed of fiberglass.

NUREG-1801 indicates that ASTM D1796 standard should be used to analyze fuel oil for water and sediment. The Dresden and Quad Cities programs use ASTM D2709 as specified by ASTM D975 for analysis of grades 1-D and 2-D fuel used at the stations.

NUREG-1801 indicates that ASTM D2?76 (Modified), which provides for field monitoring, should be used to analyze fuel oil for particulate content. The Dresden and Quad Cities programs use ASTM D5452 as the preferred method of analysis.

NUREG-1801 indicates that a modified ASTM D2276 test with a filter pore size of 3.0 pm should be utilized for detection of particulate in fuel oil.

Dresden and Quad Cities particulate tests utilize filters with a pore size of 0.8 pm instead of 3.0 pm because 0.8 pm filters provide conservative results. The use of 0.8 pm filters Is consistent with use of ASTM D5452.

NUREG-1801 discusses the need to add stabilizers and corrosion inhibitors to diesel fuel oil. Quad Cities does, not add stabilizers because grade 1-D low sulfur fuel oil is used and stored fuel is periodically sampled and analyzed for quality. Dresden and Quad Cities do not add corrosion inhibitors because fuel oil storage tank bottoms are periodically sampled and analyzed for corrosion products in accordance with ASTM D4057 and ASTM D2709. Dresden and Quad Cities employ sample techniques and Dresden and Quad Cities Page B-45 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS particulate contamination detection methods that identify fuel degradation or the presence of corrosion products at an early stage.

NUREG-1801 indicates that fuel oil tanks should be sampled for water, biological activity, and particulate on a periodic basis and that multilevel sampling of tanks should be performed. The Dresden and Quad Cities emergency diesel generator fuel oil day tanks do not have the capability of being sampled. As an alternative, Dresden and Quad Cities sample for water and sediment from the bottom of the associated storage tanks quarterly and particulate from the fuel oil transfer pump discharge line on a monthly basis in accordance with approved procedures.

Dresden and Quad Cities do not perform multilevel sampling of other fuel oil day tanks (isolation condenser makeup pump [Dresden only], fire pump, and station blackout) because the tanks are small and experience a high turnover of fuel due to routine diesel engine operations. Additionally, ASTM D4057, Table 4, "Spot Sampling Requirements,* indicates that multilevel sampling is not required for tanks with a capacity less than 42,000 gallons. The fuel oil storage tanks and day tanks at Dresden and Quad Cities are 15,000 gallons or smaller.

NUREG-1801 indicates that fuel oil sample results should be monitored and trended. At Dresden, the results of analysis of new fuel oil are reviewed for acceptability, but are not trended.

In the event the quantitative oil acceptance criteria in plant procedures are approached or exceeded the fuel oil is restored to within limits or an action request or condition report is initiated.

Enhancements The fuel oil chemistry program will provide for inspection of the fuel oil storage tank interiors for corrosion during the regularly scheduled tank cleanings and the performance of engineering evaluations in the event corrosion of the tank interiors is found.

The enhancement is scheduled for implementation at Dresden and Quad Cities prior to the period of extended operation.

Operating Experience The fuel oil chemistry aging management program has proven to be effective in identifying and correcting abnormal conditions in a timely manner. Dresden and Quad Cities have experienced a small number of events where plugging of drain lines in fuel oil system low points was caused by sediment buildup. These events did not affect the ability of the associated diesel generator or fire pump to perform its intended functions.

Quad Cities experienced plugging of both fuel filters on one diesel generator in 1998 for an indeterminate reason.

Conclusion The fuel oil chemistry aging management program provides reasonable assurance that the loss of material aging effects are adequately managed so that the intended functions of components exposed to fuel oil within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-46 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.22 Reactor Vessel Surveillance Description The reactor vessel surveillance aging management program provides management of irradiation embrittlement of the reactor pressure vessel through testing that monitors reactor vessel beltline materials.

The program is implemented through station procedures that conform to the requirements of 10 CFR 50, Appendix H, "Reactor Vessel Material Surveillance Program Requirements.'

Neutron embrittlement for the period of extended operation is predicted utilizing chemistry tables and Position 1.3 limitations as described in Regulatory Guide 1.99, Revision 2, "Radiation Embrittlement of Reactor Vessel Materials.'

The program will be consistent with the BWRVIP-78, "Integrated Surveillance Program,"

(ISP.) The program will provide for capsule testing consistent with BWRVIP-78, and saving withdrawn capsules for future reconstitution.

Additionally the program will be consistent with BWRVIP-86, "BWR Integrated Surveillance Program Implementation Plan., The ISP will increase technical quality and make most effective use of existing BWR surveillance capsules and data.

The enhanced program provides for capsule testing consistent with BWRVIP-78 and BWRVIP-86. Existing capsules not included in the current ISP will be maintained in the vessels as a contingency for the future.

The BWRVIP-78 report described the technical basis related to material selection and testing on which the proposed BWRVIP ISP was constructed. The report principally addressed the methodology established to identify existing plant-specific surveillance capsules and surveillance capsules from the Supplemental Surveillance Program initiated by the Boiling Water Reactors Owners' Group in the late 1980s, which contain important surveillance materials for inclusion within the ISP.

The BWRVIP-86 report was submitted to follow up on the material presented In the BWRVIP-78 report by establishing specific guidelines for ISP implementation.

The BWRVIP-86 report addressed determination of ISP surveillance capsule withdrawal and testing dates, information on ISP project administration, additional information on neutron fluence determination issues, additional information on data utilization and sharing, and information on licensing aspects of ISP implementation.

NUREG-1801 Consistency With enhancements the aging management program for reactor vessel surveillance is consistent with the aging management program XI.M31, "Reactor Vessel Surveillance,"

described in NUREG-1801.

Enhancements The program will provide for performance of reactor beltline material surveillance consistent with BWR ISP, BWRVIP-78, BWRVIP-86, the NRC SER for the ISP and associated RAIs.

Dresden and Quad Cities Page B-47 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience Material capsules are withdrawn and testing is performed in accordance with the program requirements. Program updating is performed as new industry standards are developed. No adverse conditions have been identified.

Conclusion The reactor vessel surveillance aging management program provides reasonable assurance that the aging effects of irradiation embrittlement are adequately managed so that the intended functions of reactor vessel components within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-48 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.23 One-Time Inspection Description The one-time inspection aging management program provides one-time inspections that manage aging effects of identified components within the scope of license renewal. The purpose of the program is to determine if a specified aging effect is occurring. If the aging effect is occurring, the program provides for evaluation of the effect it will have on the ability of affected components to perform their intended functions for the period of extended operation, and appropriate corrective action. The program is implemented through station procedures.

The program includes the following one-time inspections:

One-Time Inspections Identified In Section 3 "Further Evaluation" Discussions Inspect a sample of Class I piping less than four inch NPS exposed to reactor coolant for cracking.

Inspect a sample of torus saddle Lubnte baseplates for galvanic corrosion, wear, and lockup to confirm the condition of the inaccessible drywell radial beam Lubrite baseplates.

Inspect a sample of spent fuel pool cooling and demineralizer system (Dresden only) components for corrosion in stagnant locations to verify effective water chemistry control.

One-Time Inspections Identified In Section 3 "Further Evaluation" Discussions, and Also Applicable to Non-NUREG-1801 Components Inspect a sample of piping exposed to the containment atmosphere (safety relief valve discharge piping and HPCI turbine exhaust sample locations) for loss of material.,

Inspect a sample of condensate and torus water components for corrosion in stagnant locations to verify effective water chemistry control.

Inspect a sample of compressed gas system piping components for corrosion and a sample of compressed gas system flexible hoses for elastomer degradation.

Inspect a sample of lower sections of carbon steel fuel oil and lubricating oil tanks for reduced thickness.

Inspect a sample of fuel oil and lubricating oil piping and components for corrosion.

Dresden and Quad Cities Page B-49 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Inspect a sample of main control room ventilation, emergency diesel generator ventilation, SBO building ventilation, reactor building ventilation and standby gas treatment system components for loss of material.

One-Time Inspections Not Identified In Section 3 "Further Evaluation" Discussions These inspections are for component, material, environment, and aging effect combinations that are not addressed in NUREG-1801, and for which one-time inspections are not identified under "Further Evaluations" In LRA Section 3. Therefore, brief descriptions of the inspections are included here:

Inspect a sample of stainless steel standby liquid control (SBLC) system components not in the reactor coolant pressure boundary section of the SBLC system for cracking, to verify effective water chemistry control.

Aging of SBLC system components not in the reactor coolant pressure boundary section of SBLC system relies on monitoring and control of SBLC makeup water chemistry based on the Water Chemistry (B.1.2) aging management program. The effectiveness of the water chemistry program will be verified by a one-time VT-3 inspection of a Quad Cities SBLC pump casing and a Dresden SBLC pump discharge valve.

Inspect a sample of HPCI turbine lubricating oil hoses for age-related degradation.

A sample of lubricating oil hoses from each facility will be removed and inspected for evidence of elastomer degradation due to aging.

Inspect a sample of non-safety related vents and drains including their valves and associated piping, for age-related degradation leading to a loss of structural integrity.

A sample from each facility will be visually inspected for evidence of degradation due to aging.

Inspect a sample of 10 CFR 54.4(a)(2) components for corrosion for which the component, material, environment, aging effect, or their combination is not specifically identified in NUREG-1801.

Some components are in scope of license renewal only because they meet the 10 CFR 54.4(a)(2) criterion for

...systems, structures, or components whose failure could prevent satisfactory accomplishment of any of the (critical, in-scope] functions identified In [other sections of the license renewal rule).

Some of these components may be susceptible to corrosion, which may affect the intended in-scope function. However, the component, material, Dresden and Quad Cities Page B-50 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS environment, aging effect, or their combination may not be specifically identified in NUREG-1801.

A review of the 10 CFR 54.4(a)(2) system component materials, and their environments, found examples of industry component type-material environment combinations, which are not addressed by NUREG-1801, and include components whose failure might affect intended functions of safety related systems in the scope of license renewal. The one-time inspection procedure contains a list material-environment pairs from which a sample will be selected for inspection. The program provides a one-time, internal, visual inspection; for general, crevice, galvanic, and pitting corrosion as appropriate; on at least one component for each of the material-environment pairs.

Some of these systems met the 10 CFR 54.4(a)(2) criterion at only one of the two plants. In that case the sample location or locations will be chosen at the plant where the criterion is met.

NUREG-1801 Consistency The one-time inspection aging management program is scheduled for implementation prior to the period of extended operation. Program activities are consistent with the ten elements of aging program XI.M32, "One-Time Inspection," specified in NUREG-1801.

Operating Experience The one-time inspection program is new.

Therefore, no programmatic operating experience is available. The program is scheduled for implementation prior to the period of extended operation.

Conclusion The one-time inspection management program provides reasonable assurance that the aging effects are adequately managed so that the intended functions of components within the scope of license renewal that are covered by this program are maintained during the period of extended operation.

Dresden and Quad Cities Page B-51 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.24 Selective Leaching of Materials Description The selective leaching of materials aging management program consists of numerous one-time inspections to determine if selective leaching of materials is occurring. The scope of the program includes susceptible components within the scope of license renewal that are exposed to chemically treated water, demineralized water, raw water and ground water, and moist ventilation and gas environments. Susceptible component materials are gray cast iron, copper alloys with less than 85% copper, aluminum bronze, and Muntz metal.

The one-time inspection program includes visual inspection or other appropriate examination methods of components of the different susceptible materials selected from each applicable environment. The purpose of the program is to determine if loss of material due to selective leaching is occurring. If selective leaching is occurring, the program provides for evaluation as to the effect it will have on the ability of the affected components to perform their intended function for the period of extended operation, and the need to expand the sample of components to be tested.

NUREG-1801 Consistency The selective leaching of materials aging management program is a new program. The program is scheduled for implementation prior to the period of extended operation.

Program activities are consistent with the ten elements of aging program XI.M33, "Selective Leaching of Materials," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-I801 NUREG-1801 indicates that the selective leaching of materials aging management program includes a one-time hardness measurement of a selected set of components.

NUREG-1801 also indicates that the hardness test provides the basis for determination that the intended functions are not lost due to selective leaching induced loss of material during the period of extended operation.

The Dresden and Quad Cities programs provide for visual examination in lieu of hardness testing. Hardness testing provides definitive results only if baseline values are available for comparison purposes. Because materials in general have an acceptable ASTM hardness range rather than a specific value, definitive results may not be possible using hardness measurements. Components that exhibit visual indications of selective leaching will receive further examination or evaluation, which may include nondestructive testing or other examinations that provide definitive results regarding the presence of selective leaching.

Operating Experience The selective leaching of materials aging management program is new. Therefore, no programmatic operating experience is available.

The program is scheduled for implementation prior to the period of extended operation.

Dresden and Quad Cities Page B-52 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The selective leaching of materials aging management program will provide reasonable assurance that selective leaching aging effects are adequately managed so that the intended functions of components within the scope of license renewal are maintained during the period of extended operation.

Page B-53 Dresden and Quad Cities License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.26 Buried Piping and Tanks Inspection Description The buried piping and tanks inspection program for aging management consists of preventive and condition monitoring measures to manage loss of material due to corrosion from extemal environments for buried piping and tanks in the scope of license renewal.

Inspection of buried components uncovered during maintenance cannot be relied upon as the sole method for providing effective aging management because operating experience has demonstrated that buried piping or tanks are not likely to be uncovered during yard excavation activities due to their locations and depths of the specific routings.

Therefore, program activities as enhanced include the use of piping and component coatings and wrappings, periodic pressure testing, buried tank leakage checks, inspections of buried tank internal surfaces, and inspections of the ground above buried tanks and piping.

Enhanced activities also include a one-time visual inspection of the external surface of a buried piping section, one-time intemal UT's of buried steel tanks, and a one-time internal UT of the bottom of an outdoor aluminum storage tank.

NUREG-1801 Consistency With enhancements the buried piping and tanks inspection program for aging management is consistent with the ten elements of aging management program XI.M34, "Buried Piping and Tanks Inspection," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that buried piping and tanks are inspected when they are excavated during maintenance.

NUREG-1801 also indicates that because the inspection frequency is plant-specific and also depends on plant operating experience, the inspection frequency requires further evaluation. Inspections of Dresden and Quad Cities buried components uncovered due to maintenance cannot be relied upon as the sole method for providing effective aging management because uncovering of piping or tanks during maintenance is not likely. Therefore, the program as enhanced includes the use of piping and component coatings and wrappings, periodic pressure testing, buried tank leakage checks, inspections of buried tank internal surfaces, and inspections of the ground above buried tanks and piping. It also includes one-time internal UT's of buried steel tanks, a one-time internal UT of the bottom of an outdoor aluminum storage tank, and a one-time visual inspection of the external surface of a buried piping section.

Dresden and Quad Cities Page B-54 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Enhancements

"* The program will provide for the performance of one-time internal UT's of buried steel tanks at Dresden and Quad Cities.

"* The program will provide for the performance of a one-time UT of the bottom of an outdoor aluminum storage tank at either Dresden or Quad Cities.

"* The program will provide for periodic leakage checks of the Quad Cities buried carbon steel fuel oil storage tanks.

"* The program will provide for a one-time visual inspection of the external surface of a section of buried ductile iron fire main piping (including a mechanical joint) at Dresden and Quad Cities.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience Dresden and Quad Cities operating history shows no aging degradation induced leakage of buried fuel oil storage tanks or transfer piping. However, other buried piping has had leakage that has required repair. Some examples are:

"* Underground piping to the demineralized water storage tank at Dresden developed a leak in 1985 and required excavation and repair.

"* Six underground fire main leaks required excavation and repair at Dresden between 1988 and 1997. In none of these cases was the intended function of the fire protection system lost.

Conclusion The buried piping and tanks inspection program for aging management provides reasonable assurance that the loss of material aging effects are adequately managed so that the intended functions of buried piping and tanks within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-55 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.26 ASME Section XI. Subsection IWE Description The ASME Section XI, Subsection IWE aging management program provides for primary containment inspections for loss of material.

The program includes visual examination and limited surface or volumetric examination, when augmented examination is required. It is implemented through station plans and procedures and covers steel containment shells and their integral attachments; containment hatches and airlocks; seals, gaskets and moisture barriers; and pressure-retaining bolting.

The Quad Cities program complies with Subsection IWE for steel containments (Class MC) of ASME Section XI, 1992 Edition including 1992 Addenda.

The Dresden program utilizes a relief request. The relief request permits utilization of the 1998 Edition of Subsection IWE of ASME Section XI in its entirety instead of the 1992 Edition and Addenda.

Additionally, the protective coatings for these components are monitored as discussed in the Protective Coating Monitoring and Maintenance Program (B.1.32) aging management program. However, no relief from ASME Section XI, Subsection IWE has been requested as a result of implementing the Protective Coating Monitoring and Maintenance Program (B. 1.32).

NUREG-1801 Consistency The ASME Section XI, Subsection IWE aging management program is consistent with the ten elements of aging management program XI.S1, "ASME Section XI, Subsection IWE," specified in NUREG-1801 with the following exceptions.

Exceptions to NUREG-1801 NUREG-1801 indicates that ASME Section XI, Subsection IWE and the additional requirements specified in 10 CFR 50.55a(b)(2) constitute an existing mandated program applicable to managing aging of a steel containment. The NUREG-1801 evaluation covers both the 1992 Edition with the 1992 Addenda and the 1995 Edition with the 1996 Addenda of ASME Section XI, Subsection IWE, as approved in 10 CFR 50.55a. The Dresden program utilizes a relief request. The Dresden program is based on the 1998 Edition of Subsection IWE of ASME Section XI as provided for in Relief Request MCR-02.

NUREG-1801 indicates that pressure retaining weld visual examinations and pressure retaining dissimilar metal welds surface examinations are optional. These requirements are not part of the Dresden program because it is based on the 1998 Edition of Subsection IWE of ASME Section XI as provided for in Relief Request MCR-02.

NUREG-1801 indicates that bolt preload is checked by either a torque or tension test.

The Dresden and Quad Cities programs do not provide for checking of bolt preload by either torque or tension test because acceptance is based on Appendix J testing of Dresden and Quad Cities Page B-56 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS associated bolted components and general visual examination.

This practice is consistent with Dresden Relief Request MCR-02 and Quad Cities Relief Request CR-24.

NUREG-1801 indicates that the program provides for examination of seals, gaskets and moisture barriers by visual methods prescribed in ASME Section Xl, Subsection IWE.

The Dresden program uses Relief Request MCR-02 and the Quad Cities program uses Relief Request CR-21 as the basis for not routinely inspecting seals and gaskets, and the extent of surface examination of moisture barriers. Aging management program 10 CFR Part 50, Appendix J (B.1.28) provides for monitoring of seals and gaskets.

Seals and gaskets are inspected only when sealed or gasketed components are disassembled for maintenance. Moisture barriers, which are accessible, are examined for tears, cracks or other damage that would allow intrusion of moisture, using general visual criteria.

Operating Experience The operating experience of the inservice inspection (ISI) programs at Dresden and Quad Cities, which includes ASME Section XI, Subsection IWE aging management program activities, has not shown any adverse trend of program performance. Periodic self-assessments of the ISI programs have been performed to identify the areas that need improvement to maintain program quality.

Inspections were conducted on Dresden Unit 3 drywell in response to NRC Generic Letter (GL) 87-05, "Request for Additional Information Assessment of Licensee Measures to Mitigate and or Identify Degradation of Mark I Drywells," and Information Notice 86-99, "Degradation of Steel Containments," which addressed the potential for corrosion of boiling water reactor (BWR) Mark I steel drywells in the "sand pocket region.' The results of these inspections and analysis of the results concluded that ultrasonic examinations showed evidence of no apparent corrosion of liner in the "sand pocket region." The conclusions were found to also apply to Dresden Unit 2 and both Quad Cities units, as Dresden Unit 3 conditions were determined to be bounding based on more occasions of moisture in its sand pocket region. Dresden Unit 3 has experienced leakage from the drywell sand pocket drains during refueling outages in 1997 and 2000. As a result, an augmented UT inspection of the Unit 3 drywell sand pocket area is scheduled for the second haWt of 2002.

Conclusion The ASME Section XI, Subsection IWE aging management program provides reasonable assurance that the loss of material aging effects are adequately managed so that the intended functions of primary containment components are maintained during the period of extended operation.

Dresden and Quad Cities Page B-57 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.27 ASME Section XI, Subsection IWF Description The ASME Section XI, Subsection IWF aging management program provides for visual examination of component and piping supports within the scope of license renewal for loss of material and loss of mechanical function aging effects.

The program is implemented through station procedures, which provide for visual examination of inservice inspection Class 1, 2, and 3 supports in accordance with the requirements of ASME Section XA, Subsection IWF, 1989 Edition and Code Case N-491-1.

NUREG-1801 Consistency With enhancements the ASME Section XI, Subsection IWF aging management program is consistent with the ten elements of aging management program XI.S3, "ASME Section XI, Subsection IWF," specified in NUREG-1 801.

Enhancements The program will provide for inspection of Class MC component supports consistent with NUREG-1 801, Chapter III, Section B1.3.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience The operating experience of the inservice inspection (ISI) programs at Dresden and Quad Cities, which include ASME Section XI, Subsection IWF aging management program activities, has not shown any adverse trend of program performance. Periodic self-assessments of the ISI programs have been performed to identify the areas that need improvement to maintain program quality.

Conclusion The aging management program provides reasonable assurance that the loss of material and loss of mechanical function aging effects are adequately managed so that the intended functions of component and piping supports within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-58 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.28 10 CFR Part 50. Appendix J Description The 10 CFR Part 50, Appendix J aging management program provides for aging management of pressure boundary degradation due to loss of material in the primary containment and various systems penetrating primary containment. The program also manages changes in material properties of gaskets, o-rings, and packing materials for the primary containment pressure boundary access points.

The program consists of tests performed in accordance with the regulations and guidance provided in 10 CFR 50 Appendix J, "Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors,n Option B, Regulatory Guide 1.163, "Performance-Based Containment Leak-Testing Program," NEI 94-01, "Industry Guideline for Implementing Performance-Based Options of 10 CFR Part 50, Appendix J," ANSI/ANS 56.8, "Containment System Leakage Testing Requirements," and station procedures. Containment leak rate tests are performed to assure that leakage through the primary containment and systems and components penetrating primary containment does not exceed allowable leakage limits specified in the Technical Specifications. An integrated leak rate test (ILRT) is performed during a period of reactor shutdown at the frequency specified in 10 CFR Part 50, Appendix J, Option B.

Local leak rate tests (LLRT) are performed on isolation valves and containment access penetrations at frequencies that comply with the requirements of 10 CFR 50 Appendix J, Option B.

NUREG-1801 Consistency The 10 CFR Part 50, Appendix J aging management program is consistent with the ten elements of aging management program XI.S4, "10 CFR Part 50, Appendix J," specified in NUREG-1801.

Operating Experience The industry has found that the 10 CFR Part 50, Appendix J testing program has been effective in maintaining the pressure integrity of the containment boundaries, including identification of leakage within the various systems' pressure boundaries.

The Dresden and Quad Cities facilities have demonstrated experience in effectively maintaining the integrity of the containment boundaries as evidenced by the selection of Option B of 10 CFR 50 Appendix J leakage testing requirements. Both stations have experienced "as found" LLRT results in excess of Individual containment penetration administrative limits. Evaluations were performed and corrective actions were taken to restore the individual penetration leakage rates to within the established administrative leakage limits in accordance with the Appendix J testing program.

Dresden and Quad Cities Page B-59 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The 10 CFR Part 50, Appendix J aging management program provides reasonable assurance that the loss of material and changes in material properties aging effects are adequately managed so that the intended functions of primary containment components within the scope of license renewal are maintained during the period of extended operation.

Page B-60 Dresden and Quad Cities License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.29 Masonry Wall Program Description The masonry wall program, which is part of the structures monitoring program, is based on guidance provided in I. E. Bulletin 80-11, "Masonry Wall Design," and Information Notice 87-67, "Lessons Learned from Regional Inspections of Licensee Actions in Response to I. E. Bulletin 80-11," and is implemented through station procedures. The program provides for inspections of masonry walls within the scope of license renewal for cracking.

The program includes all masonry walls that perform intended functions in accordance with 10 CFR 54.4, and provides for management of aging effects so that the established evaluation basis for each masonry wall within the scope of license renewal remains valid through the period of extended operation.

NUREG-1801 Consistency The masonry wall program is consistent with the ten elements of aging management program XI.S5, "Masonry Wall Program," specified in NUREG-1 801.

Operating Experience The masonry wall program has provided for detection of cracks, and other minor aging effects in masonry walls. The corrective action process has ensured timely repair in order to prevent continued degradation.

Maintenance history revealed minor degradation of masonry block walls. In response to I. E. Bulletin 80-11, Masonry Wall Design," and Information Notice 87-67, 6Lessons Learned from Regional Inspections of Licensee Actions in Response to I. E. Bulletin 80-11," various actions were taken.

Actions included program enhancements, follow-up inspections to substantiate masonry wall analyses and classifications, and the development of procedures for tracking and recording changes to the walls. These actions addressed all concerns raised by I. E.

Bulletin 80-11 and Information Notice 87-67, namely unanalyzed conditions, improper assumptions, improper classification, and lack of procedural controls. Operating history shows that the program was and continues to be assessed for its effectiveness based on program specific corrective actions that addressed issues such as inspection schedules and program database discrepancies.

Conclusion The masonry wall program provides reasonable assurance that the aging effects of cracking are adequately managed so that the intended functions of masonry walls within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-61 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.30 Structures Monitoring Program Description The structures monitoring program provides for aging management of various structures and external surfaces of mechanical components within the scope of license renewal.

The program, which was developed for structures monitoring under 10 CFR 50.65, "Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants," is based on the guidance in Regulatory Guide 1.160 Revision 2, "Monitoring the Effectiveness of Maintenance at Nuclear Power Plants," and NUMARC 93-01 Revision 2, "Industry Guidelines for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants," and implemented through procedures. The program is not credited for managing protective coatings.

The program will provide for visual inspections of structures and components not included in the ASME Section XI, Subsection IWF (B.1.27) aging management program.

NUREG-1801 Consistency With enhancements the structures monitoring aging management program is consistent with the ten elements of aging management program XI.S6, "Structures Monitoring Program," specified in NUREG-1801.

Enhancements The program will provide for inspections of structural steel components in secondary containment, flood barriers, electrical panels and racks, junction boxes, instrument racks and panels, offsite power structural components and their foundations, and the Quad Cities discharge canal weir as part of the ultimate heat sink.

The program will provide for periodic reviews of chemistry data on below-grade water to confirm that the environment remains non-aggressive for the license renewal term for the aging mechanisms of corrosion of embedded steel and aggressive chemical attack of concrete.

"* The program will provide for inspection of a sample of non-insulated indoor piping external surfaces at locations immediately adjacent to periodically inspected piping supports.

Program procedures will reference specific insulation inspection criteria for existing cold weather preparation and inspection procedures for outdoor insulation, and establish new inspections for various indoor area piping and equipment insulation.

"* The program will provide for inspection parameter specificity for non-structural joints, roofing, grout pads and isolation gaps.

Dresden and Quad Cities Page B-62 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS The program will extend inspection criteria to the structural steel, concrete, masonry walls, equipment foundations, and component support sections of the program to provide consistency with NUREG-1801 component supports.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience Roof leaks were detected and corrective actions taken for the Dresden turbine building and main control room and for the Quad Cities reactor building and turbine building.

Minor degradation of concrete has been detected such as cracks with water stains, pitting, and leaching for various structures including the Dresden reactor building and crib house. Similar degradation has been detected in the Quad Cities reactor building and circulating water intake bays. The degradation was evaluated and dispositioned in accordance with the corrective action process.

Cracks and small gaps were detected in elastomer seals at both Dresden and Quad Cities. Most of the degraded conditions were attributed to man-made occurrences.

None were determined to be significant.

Damage and degradation of insulation has been observed and repaired.

Conclusion The structures monitoring program for aging management provides reasonable assurance that the aging effects are adequately managed so that the intended functions of structures within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-63 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.31 RG 1.127, Inspection of Water-Control Structures Associated with Nuclear Power Plants Description The RG 1.127, "Inspection of Water-Control Structures Associated with Nuclear Power Plants," aging management program is part of the structures monitoring program and consists of procedures that provide for condition monitoring of structural steel elements and concrete.

With enhancements the program provides for visual inspections of structural steel and concrete components within the scope of license renewal that are in the Unit I and Unit 2 and 3 crib houses at Dresden, and the Unit I and 2 crib house and discharge canal weir structure supporting the ultimate heat sink at Quad Cities. The program provides for aging management of concrete and structural steel elements exposed to raw water and aging management of concrete not exposed to raw water, and is based on Regulatory Guide 1.127, Revision 1.

NUREG-1801 Consistency With enhancements the RG 1.127 aging management program is consistent with the ten elements of aging management program XI.S7, "RG 1.127, Inspection of Water-Control Structures Associated with Nuclear Power Plants," specified in NUREG-1801.

Enhancements

"* The program will provide for monitoring of crib house concrete walls and slabs with an opposing side in contact with river water and the Quad Cities discharge canal weir.

Procedures will be revised to emphasize inspecting for structural integrity of concrete and steel components and identify specific types of components to be inspected.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience Operating history of crib houses at Dresden and Quad Cities indicates that structural components are not experiencing any significant degradation.

Minor degradation of concrete has been detected such as cracks with water stains, pitting, and leaching.

These types of degradation were evaluated and dispositioned.

The effective use of the corrective action process has provided significant quantitative and qualitative data on performance, extent of degradation, and effects of operating and environmental conditions ensuring timely identification and correction of degraded conditions. The program has been assessed for its effectiveness based on program specific corrective actions that addressed issues such as inspection schedules and program database discrepancies.

Dresden and Quad Cities Page B-64 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The RG 1.127, Inspection of Water-Control Structures Associated with Nuclear Power Plants,* aging management program provides reasonable assurance that the aging effects are adequately managed so that the intended functions of concrete and structural steel components in water control structures within the scope of license renewal are maintained during the period of extended operation.

Dresden and Quad Cities Page B-65 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.32 Protective Coating Monitoring and Maintenance Program Description The protective coating monitoring and maintenance program provides for aging management of Service Level I coatings inside primary containment. Service Level I coatings are used in areas where the coating failure could adversely affect the operation of post-accident fluid systems and thereby impair safe shutdown.

The program provides for visual inspections to identify any condition that adversely affects the ability of the coating film to function as intended. It is implemented through procedures based on the technical and quality requirements of Regulatory Guide 1.54, Revision 0, uQuality Assurance Requirements for Protective Coatings Applied to Water Cooled Nuclear Power Plants," and ANSI N101 4-1972, "Quality Assurance for Protective Coatings Applied to Nuclear Facilities," and the guidance provided in EPRI TR-109937, "Guidelines on Nuclear Safety-Related Coating."

NUREG-1801 Consistency With enhancements the protective coating monitoring and maintenance program is consistent with the ten elements of aging management program XI.S8, "Protective Coating Monitoring and Maintenance Program," specified in NUREG-1801.

Enhancements

"* Procedure revisions will provide for thorough visual inspections of Service Level I coatings near sumps or screens associated with the emergency core cooling system.

"* Procedure revisions will provide for pre-inspection reviews of previous reports so that trends can be identified.

"* Procedure revisions will provide for analysis of suspected reasons for coating failure.

Enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience Examinations of the Dresden internal drywell accessible steel surfaces during refueling outages revealed the original coatings were acceptable other than exhibiting minor surface rust, paint flaking and discoloration.

No significant degradation has been identified in the corrective action process records.

Dresden and Quad Cities Page B-66 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS The internal surfaces of the torus for each of the Dresden units were re-coated with an epoxy coating in the late 1980's dudng refuel outages D2R11 I and D3R10. Surveillance of the coated torus internal surfaces during refueling outages has resulted in local coating repairs. A review of past inspections of the torus shells indicates the majority of the problems have been attributed to blistering of coating in small areas, localized pitting, and mechanical damage. Since the application of the epoxy protective coating on the internal surfaces, torus wall thinning has not been an issue.

Inspections of drywell steel at Quad Cities have not identified any significant coating or corrosion problems requiring repair of the torus. In 1994 the Quad Cities Unit I torus internal surface corrosion was removed and the base metal was re-coated. During the subsequent refueling outage the torus shell immersion area was inspected.

Coating deficiencies, such as mechanical damage, burrs and projections were identified and repaired.

Minor local repairs to the coating on the inside of the Quad Cities Unit 2 torus were performed in March 1974. Inspections are conducted each outage, with local coating repairs performed as required.

Conclusion The protective coating monitoring and maintenance program provides reasonable assurance that aging effects are adequately managed so that the intended functions of Service Level 1 coatings inside primary containment are maintained during the period of extended operation.

Dresden and Quad Cities Page B-67 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.33 Electrical Cables and Connections Not Sublect to 10 CFR 50.49 Environmental Qualification Requirements Description The aging management program for electrical cables and connections not subject to 10 CFR 50.49 environmental qualification requirements manages cables and connections within the scope of license renewal that are subject to an adverse environment.

It also identifies and manages cables and connections subject to an adverse localized environment. The aging management program for electrical cables and connections not subject to 10 CFR 50.49 environmental qualification requirements is a new program.

An adverse localized environment is a condition in a limited plant area that is significantly more severe than the specified service environment for a subject cable or connection.

An adverse variation in environment is significant if it could appreciably increase the rate of aging of a component or have an immediate adverse effect on operability.

Cables and connections subject to an adverse environment are managed by inspection of a sample of these components. Selected cables and connections from accessible areas are inspected and represent, with reasonable assurance, the cables and connections in adverse environments. They are inspected for signs of accelerated age related degradation.

Additional inspections, repair or replacement are initiated as appropriate.

Samples of cables and connections found to be located in adverse localized areas will be inspected prior to the period of extended operation, with an inspection frequency of at least once every 10 years. The scope of this program includes inspections of power, control and instrumentation cables and connections located in adverse localized areas, including the cables used in instrumentation circuits that are sensitive to reduction in conductor insulation resistance.

NUREG-1801 Consistency The aging management program for electrical cables and connections not subject to 10 CFR 50.49 environmental qualification requirements is a new program. The program is scheduled for implementation prior to the period of extended operation.

Program activities are consistent with the ten elements of aging program XI.EI, "Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements," specified in NUREG-1801.

Operating Experience This program is new. Therefore, no programmatic operating experience is available.

However, existing activities provide for inspection of butyl rubber insulated environmentally qualified cables in heater bays to assess aging of cable insulation.

These cables are in an adverse environment. No adverse trends Indicative of premature aging of cables have been identified. Cable failures, when Identified, are subject to the Dresden and Quad Cities Page B-68 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS station corrective action program. Operating experience does not indicate the presence of localized adverse environment or premature aging of cable insulation.

Conclusion The aging management program for electrical cables and connections not subject to 10 CFR 50.49 environmental qualification requirements provides reasonable assurance that aging effects are adequately managed so that the intended functions of these types of cables and connections are maintained during the period of extended operation.

Dresden and Quad Cities Page B-69 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.34 Metal Fatigue of Reactor Coolant Pressure Boundary Description The aging management program for metal fatigue of reactor coolant pressure boundary provides for monitoring fatigue stress cycles to ensure that the design fatigue usage factor limit is not exceeded.

NUREG-t801 Consistency With enhancements the metal fatigue of reactor coolant pressure boundary aging management program is consistent with the ten elements of aging management program X.M1,

=Metal Fatigue of Reactor Coolant Pressure Boundary," specified in NUREG-1801.

Enhancements

" The program will use the EPRI-licensed FatiguePro cycle counting and fatigue usage factor tracking computer program. The computer program provides for calculation of stress cycles and fatigue usage factors from operating cycles, automated counting of fatigue stress cycles and automated calculation and tracking of fatigue cumulative usage factors.

"* The program will provide for calculating and tracking of the cumulative usage factors for bounding locations for the reactor pressure vessel, Class I piping, the torus, torus vents, and torus attached piping and penetrations.

"* The program will provide for tracking of fatigue stress cycles for the Dresden isolation condenser.

The enhancements are scheduled for implementation prior to the period of extended operation.

Operating Experience The reactor vessel cycle counting programs have been revised to incorporate changes in design basis analysis cycles. The changes were made because certain types of operating events were found to be more frequent than anticipated in the original design.

Others were found to be less frequent. The changes reduced the assumed design basis number of the less-frequent events and increased the assumed number of the more frequent events.

In response to NRC concerns that early-life operating cycles at some units had caused fatigue usage factors to increase at a greater rate than anticipated in the design analyses the industry sponsored the development of the FatiguePro computer program. The program is designed to ensure that the code limits are not exceeded for the remainder of each unit's licensed life and provides for incorporation of operating experience.

Dresden and Quad Cities Page B-70 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion The aging management program for metal fatigue of reactor coolant pressure boundary provides reasonable assurance that the thermal and pressure transient aging effects are adequately managed so that the intended functions of pressure boundary components within the scope of license renewal that are covered by this program are maintained during the period of extended operation.

Dresden and Quad Cities Page B-71 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.35 Environmental Qualification (EQ) of Electrical Components Description The environmental qualification (EQ) of electrical components aging management program is implemented through station procedures and predefined tasks. The Dresden and Quad Cities EQ program complies with 10 CFR 50.49, "Environmental Qualification of Electrical Equipment Important to Safety for Nuclear Power Plants.0 All EQ equipment is included within the scope of license renewal. The program provides for maintenance of the qualified life for electrical equipment important to safety within the scope of 10 CFR 50.49. Program activities establish, demonstrate, and document the level of qualification, qualified configuration, maintenance, surveillance and replacement requirements necessary to meet 10CFR50.49. Qualified life is determined for equipment within the scope of the EQ program and appropriate actions such as replacement or refurbishment are taken prior to or at the end of the qualified life of the equipment so that the aging limit is not exceeded.

NUREG-1801 Consistency The environmental qualification (EQ) of electrical components aging management program is consistent with the ten elements of aging management program X.E1, "Environmental Qualification (EQ) of Electrical Components," specified in NUREG-1801.

Operating Experience The environmental qualification (EQ) of electrical components aging management program provides for consideration of operating experience to reconcile qualification bases and conclusions, including the equipment qualified life. Operating experience and system, equipment or component related information, as reported through NRC Bulletins, Notices, Circulars, Generic Letters and Part 21 Notifications, are evaluated for applicability. The evaluations are documented and corrective actions are identified.

The EQ Program requires inclusion of changes mandated by closure of Generic Safety Issue 168 (GSI-168), "Environmental Qualification of Electrical Equipment.'

The NRC letter to NEI of June 2, 1998 states that no additional information is required to address GSI-168 in a license renewal application at this time.

Operating experience has demonstrated that the program manages aging as required by 10 CFR 50.49. When problems have been identified through industry or plant-specific experience, corrective actions have been taken to prevent recurrence.

Conclusion The environmental qualification (EQ) of electrical components aging management program provides reasonable assurance that aging effects are adequately managed so that the intended functions of components within the scope of 10 CFR 50.49 are maintained during the period of extended operation.

Dresden and Quad Cities Page B-72 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.1.36 Boraflex Monitoring (Quad Cities Only)

Description The Quad Cities Boraflex monitoring program is based on EPRI TR-108761, "A Synopsis of the Technology Developed to Address the Boraflex Degradation Issue."

(Note: The Boraflex monitoring aging management program is not applicable to Dresden because the station utilizes Boral as the neutron absorbing material in the spent fuel racks rather than Boraflex.)

The Quad Cities Boraflex monitoring program consists of condition monitoring activities based on the maintenance rule and implemented at a predefined frequency. Station procedures provide for inspection testing and analysis of the Boraflex neutron absorbing capability to assure that the 5% subcriticality margin is maintained.

Degradation monitoring is accomplished by obtaining a computer-generated (RACKLIFE) value of boron loss, which is evaluated against the acceptance criteria.

The evaluation is performed every two years. The RACKLIFE program was validated through neutron attenuation testing (blackness testing), and boron areal density testing using the BADGER device. Between evaluations, spent fuel pool silica levels are monitored and adverse trends identified through chemistry programs.

NUREG-1801 Consistency The Boraflex monitoring aging management program for Quad Cities is consistent with the ten elements of aging management program XI.M22, "Boraflex Monitoring," specified in NUREG-1801.

Operating Experience The Quad Cities Boraflex monitoring aging management program has been effective at determining boron loss. To date, a boron loss of approximately one percent has been identified and trended. A review of the program resulted in updating the RACKLIFE program every two years to be consistent with maintenance rule requirements.

Conclusion The Quad Cities Boraflex monitoring aging management program provides reasonable assurance that the aging effects are adequately managed so that the 5% subcriticality margin of the Boraflex is maintained during the period of extended operation.

Dresden and Quad Cities Page B-73 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.2 PLANT-SPECIFIC AGING MANAGEMENT PROGRAMS B.2.1 Corrective Action Program Description The applicable elements of the Exelon Quality Assurance Program (QAP), implemented at Dresden and Quad Cities, were used for those aspects of the Aging Management Review process that affect the quality of safety related structures, systems, and components. The Exelon QAP is based on the 18 point criteria set forth in 10 CFR 50, Appendix B, "Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants." For non-safety related structures and components subject to an AMR, the same existing 10 CFR Part 50, Appendix B based QA program was used to address the elements of corrective actions, confirmation process, and administrative controls. The QAP addresses all aspects of quality assurance at Dresden and Quad Cities and is described in Exelon Generation Company, LLC, QATR EGC-1A, Revision 69, which endorses ASME NQA-1-1989 as the quality standard.

The elements of the QAP most pertinent to aging management programs credited for license renewal are corrective action, confirmation process, and administrative controls.

The confirmation process ensures that corrective actions to prevent recurrence of significant conditions are adequately completed and are effective.

Administrative controls provide a review and approval process.

NUREG-1801 describes how a license renewal applicant may rely on the existing requirements in 10 CFR Part 50, Appendix B, *Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants,"

to satisfy these program elements/attributes.

Branch Technical Position IQMB-1 describes an acceptable process for implementing the corrective actions, confirmation

process, and administrative controls elements of aging management programs for license renewal.

The requirements of the corrective action, confirmatory process, and administrative control elements will be applied to all structures, systems and components (SSC) within the scope of license renewal.

A review of the elements that make up a sound AMP provided in NUREG-1800 have been used to evaluate the Exelon QAP. The results are provided below. The same model was used to evaluate each of the Aging Management Programs credited for license renewal provided in Appendix B of this application.

Evaluation and Technical Basis (1)

Scope of Program: The Exelon program applies without limitation to safety related or ASME code structures, systems, components, and activities. It also applies to certain non-safety related structures, systems, components and activities to a degree consistent with their importance to safety.

Dresden and Quad Cities Page B-74 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS The plant corrective action process applies to all plant systems, structures and components (both safety related and non-safety related) within the scope of license renewal. Administrative controls are in place for existing aging management programs and activities.

Administrative controls will also be applied to new and enhanced programs and activities as they are implemented. As a minimum, these programs and activities are or will be performed in accordance with written procedures that are or will be reviewed and approved in accordance with the QAP.

(2)

Preventive Actions: The corrective action program provides a means to correct conditions identified as being adverse to quality. There are no preventive or mitigative attributes specifically credited for the corrective action program.

(3)

Parameters Monitored/inspected: No specific parameters are inspected or monitored as part of the corrective action program.

Generally, when parameters inspected or monitored by other plant programs indicate a condition adverse to quality, the corrective action program provides a means to correct the identified condition.

(4)

Detection of Aging Effects: Detection of aging effects is not part of the corrective action program. The corrective action program provides a means to address aging effects identified by other aging management activities.

(5)

Monitoring and Trending: The corrective action process is monitored to ensure that corrective actions taken are timely. Significant and non-significant conditions are trended. Significant conditions that are adverse to quality are monitored and require formal cause determination and corrective actions to prevent recurrence. The corrective actions to prevent recurrence are monitored for effectiveness.

(6)

Acceptance Criteria: The corrective action program does not include specific acceptance criteria for in scope components. Generally, when the acceptance criteria of other aging management activities are not met, the corrective action program provides a means to ensure appropriate corrective actions are taken.

(7)

Corrective Actions: Corrective action is initiated following the identification of conditions adverse to quality, and is documented. The corrective action program is described in Chapter 16 of the QAP. The various components of the corrective action program provide for timely actions, including determination of the cause of the condition and corrective action taken to preclude recurrence for significant conditions adverse to quality. Condition reports are analyzed for adverse trends. Identified adverse trends are reported to the appropriate manager and documented on a condition report.

(8)

Confirmation Process: Condition reports are reviewed by supervisors.

Operations shift management is contacted as necessary to discuss potential operability or regulatory reportability of the condition. Items determined to be significant conditions adverse to quality are reported to the appropriate levels of management.

An effectiveness review is completed for root cause analysis corrective actions to prevent recurrence.

(9)

Administrative Controls: Activities affecting quality are prescribed by documented instructions, procedures, drawings, or specifications of a type appropriate to the circumstances and are accomplished In accordance with these instructions, procedures, drawings or specifications. They contain appropriate acceptance criteria Dresden and Quad Cities Page B-75 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS and documentation requirements for determining whether important activities have been satisfactorily accomplished. The document control process is described in Chapter 6 of the QAP.

(10)

Operating Experience: The corrective action program provides for evaluation of aging effects and significant operating events and requires that reasonable actions be taken to enhance programs and activities to prevent future occurrences.

The other aging management programs described in the Dresden and Quad Cities LIRA Appendix B provide examples of the corrective action program being used to address and correct aging related conditions adverse to quality.

Conclusion Exelon has established a quality assurance program that is implemented at Dresden and Quad Cities. The QAP is based on the criteria set forth in 10 CFR 50, Appendix B, "Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants."

The QAP addresses all aspects of quality assurance at Dresden and Quad Cities.

Based on the application of industry standards and Dresden and Quad Cities operating experience, there is reasonable assurance that the corrective action program will adequately manage the aging effects so that intended functions will be maintained consistent with the current licensing basis for the period of extended operation.

Dresden and Quad Cities Page B-76 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.2.2 Periodic Inspection of Non-EQ, Non-Segregated Electrical Bus Ducts Description This program inspects the non-segregated bus ducts that connect the reserve auxiliary transformers to the 4160V ESF buses. They are normally energized, and therefore, the bus duct insulation material will experience temperature rise due to energization, which may cause age-related degradation during the extended period of operation. These bus ducts are in scope of license renewal but are not subject to 10 CFR 50.49 environmental qualification.

These non-EQ, non-segregated bus ducts will therefore be inspected periodically during the period of extended operation. This inspection program considers the technical information and guidance provided in IEEE Standard P1205, "IEEE Guide for Assessing, Monitoring and Mitigating Aging Effects on Class 1E Equipment Used in Nuclear Power Generating Stations," SAND 96-0344, "Aging Management Guidelines for Commercial Nuclear Power Plants -

Electrical Cable and Terminations,* and EPRI-109619, "Guideline for the Management of Adverse Localized Equipment Environments.'

The non-segregated bus duct internal components and materials are visually inspected under station inspection procedures for signs of aging degradation that indicate possible loss of insulating function.

Repair or rework is initiated as required to maintain the operating functions of the bus ducts.

This is a new program and will be implemented prior to the period of extended operation.

Evaluation and Technical Basis (1)

Scope of Activity: This Inspection program applies to the normally-energized non-segregated bus ducts within the scope of license renewal, not subject to the environmental qualification requirements of 10 CFR 50.49, which can be affected by elevated temperatures prior to the end of the extended period of operation.

(2)

Preventive Actions: This is an inspection program only. This program does not prevent or mitigate aging degradation.

(3)

Parameters Monitored/linspected: Accessible normally-energized non segregated bus duct internal components are visually inspected for insulation material surface anomalies, such as embrittlement, discoloration, cracking, chipping, or surface contamination.

(4)

Detection of Aging Effects: Normally-energized non-segregated bus ducts that connect the reserve auxiliary transformers to the 4160V ESF buses are inspected at least once every 10 years for material surface anomalies which are precursors to any onset of insulation failure due to temperature or radiation degradation. Experience has shown that aging degradation is a slow process. This frequency is therefore adequate to preclude age-related failures of the conductor insulation.

(5)

Monitoring and Trending: Trending is not included in this activity because the parameters inspected are difficult to quantify. The 10-year inspection frequency will Dresden and Quad Cities Page B-77 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS however provide at least 2 data points within 20 years, which will permit some characterization of the rate of degradation.

(6)

Acceptance Criteria: The accessible normally-energized non-segregated bus ducts are to be free from unacceptable visual indications.

Unacceptable visual indications are duct insulation material surface anomalies which suggest that bus duct insulation degradation exists, which if left unmanaged, could lead to a loss of the intended function, as determined by an engineering evaluation.

(7)

Corrective Actions: Further investigation and evaluation are performed when the acceptance criterion is not met in order to ensure that the intended functions will be maintained consistent with the current licensing basis. Corrective actions may include but are not limited to increased inspection frequency, replacement, or rework of the affected bus duct insulation components.

(8)

Confirmation Process: Site quality assurance procedures, review and approval processes, and administrative controls are implemented in accordance with the requirements of 10 CFR Part 50, Appendix B.

(9)

Administrative Controls: See Item 8, above.

(10)

Operating Experience: No age-related bus duct insulation failures that would indicate aging to be a concern at Dresden or Quad Cities have been identified.

However, industry experience indicates that high temperatures may cause degradation of electrical insulation materials. Some visual surface indications of high-temperature degradation in bus duct electrical insulation, such as color changes or surface cracking, have been observed in the industry.

Conclusion The inspection program for the non-EQ, non-segregated electrical bus ducts that connect the reserve auxiliary transformers to the 4160V ESF buses will provide reasonable assurance that the intended function of the non-EQ, non-segregated bus ducts will be maintained consistent with the current licensing basis for the period of extended operation.

Dresden and Quad Cities Page B-78 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.2.3 Periodic Inspection of Ventilation System Elastomers Description NUREG-1801 Sections V.B1, V.B2, VII.F1, VII.F3, and VII.F4 state that ventilation system elastomers used for flexible boots, access door seals, and filter seals are susceptible to hardening and loss of strength, and loss of material aging effects. The NUREG-1801 aging management program (AMP) column for these sections states that a plant-specific aging management program is to be evaluated.

The improved program for periodic inspection of ventilation system elastomers provides routine inspection of certain elastomers in ventilation systems in accordance with plant procedures and predefined tasks.

Dresden and Quad Cities perform routine inspections of elastomer seals and flexible boots installed in the standby gas treatment and main control room ventilation systems in accordance with approved plant procedures and predefined tasks. Dresden currently performs partial inspections of the reactor building ventilation and the station blackout and emergency diesel generator building ventilation system elastomer seals. Access door seals are inspected during the periodic damper inspections.

The improved program includes inspections for cracking, loss of material, or other evidence of aging of all flexible boots, access door seals and gaskets, filter seals and gaskets, and RTV silicone used as a duct sealant, in the components of these systems that are within the scope of license renewal. The improved program tests seals for hardening if evidence of aging is found.

Improvements are scheduled for implementation prior to the period of extended operation.

Evaluation and Technical Basis (1)

Scope of Activity: The program inspects elastomers utilized In ventilation systems within the scope of license renewal, including flexible boots, access door seals, filter seals, and RTV used as a duct sealant.

These elastomers prevent external leakage and bypass of HEPA and carbon filters. These inspections apply to the standby gas treatment system and ventilation systems within the scope of license renewal; that is, to the main control room ventilation, station blackout diesel generator building ventilation, Dresden reactor building ventilation, and Quad Cities emergency diesel generator building ventilation systems.

Exelon may elect to periodically replace certain ventilation system elastomer and RTV seals, instead of inspecting them. Periodic replacement will be evaluated on a case-by case basis.

(2)

Preventive Actions: The ventilation system elastomer inspections do not provide any preventative actions. The inspections provide condition monitoring to detect degradation prior to a loss of function.

Dresden and Quad Cities Page B-79 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS (3)

Parameters Monitored/Inspected: Visual inspections of elastomers used in ventilation systems determine if aging degradation is occurring. Flexible boots, access door seals and gaskets, filter seals and gaskets, and RTV used as a duct sealant are inspected to ensure they are free of cracking, loss of material, and damage. The seals will be tested for hardening if cracking or loss of material is noted. For the standby gas treatment and main control room ventilation systems, the results of the elastomer inspections are verified by the performance of system leakage tests and filter efficiency tests.

(4)

Detection of Aging Effects: The elastomer inspections are performed at intervals sufficient to detect aging prior to the equipment failing a leakage test or filter efficiency test. The seals will be inspected for hardening if cracking or loss of material is observed. See Item 10, below.

(5)

Monitoring and Trending: The conditions of the elastomers used in ventilation systems are monitored, but not trended. Flexible boots, filter seals, and access door seals and gaskets are repaired or replaced if damage or deterioration is detected.

(6)

Acceptance Criteria: Elastomers are inspected for cracking, loss of material, and damage. The seals will be inspected for hardening if cracking or loss of material is observed.

The seals are repaired or replaced if a degraded condition is found.

Surveillance tests of the standby gas treatment and main control room ventilation systems ensure that system leakage meets the requirements of the current licensing basis.

(7)

Corrective Actions: If cracking, loss of material, or damage are observed; or if a hardness test does not meet the acceptance criterion, a condition report is initiated to document the concem in accordance with plant administrative procedures.

The corrective actions program ensures that conditions adverse to quality are promptly corrected. If the deficiency is found to be significantly adverse to quality, the cause of the condition is determined and an action plan is developed to preclude recurrence.

(8)

Confirmation Process: Site quality assurance procedures, review and approval processes, and administrative controls are implemented in accordance with the requirements of 10 CFR Part 50, Appendix B.

(9)

Administrative Controls: See Item 8, above.

(10)

Operating Experience: Dresden and Quad Cities have experienced leaks in ventilation systems due to deterioration of or damage to elastomers, including flexible boots and access door seals and gaskets. The leaks were found and corrected in a timely manner and did not result in a loss of function of the ventilation system train.

Dresden and Quad Cities Page B-80 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Conclusion Inspections of ventilation system elastomers will be enhanced to include all flexible boots, access door seals and gaskets, and filter seals and gaskets of systems within the scope of license renewal. This enhancement will provide assurance that the ventilation system elastomers are routinely inspected for deterioration and damage, and will adequately manage the elastomer aging effects.

The program provides reasonable assurance that intended functions are maintained consistent with the current licensing basis during the period of extended operation.

Dresden and Quad Cities Page B-81 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.2.4 Periodic Testing of Drywell and Torus Spray Nozzles Description The periodic tests of drywell and torus spray nozzles address a NUREG-1801 Section V.D2.5 concern that flow orifices and spray nozzles in the drywell and torus spray subsystems are subject to plugging by rust from carbon steel piping components, and therefore a plant-specific aging management program is to be evaluated.

The Dresden and Quad Cities drywell and torus spray nozzles are bronze. There are no carbon steel flow orifices in the system piping, within the scope of license renewal.

However, upstream carbon steel piping is subject to possible general corrosion. These periodic tests use approved plant procedures to verify that the drywell and torus spray nozzles are free from plugging that could result from corrosion product buildup from upstream sources.

Evaluation and Technical Basis (1)

Scope of Activity: The tests include the drywell and torus spray nozzles.

(2)

Preventive Actions: The spray nozzle tests do not provide any preventative actions. The spray nozzle tests provide condition monitoring to detect the degradation prior to a loss of function.

(3)

Parameters Monitored/inspected: The flow tests demonstrate that the drywell and torus spray nozzles are not blocked by debris or corrosion products, and thereby demonstrate that the nozzles are available to provide the drywell and torus steam quenching functions. Drywell nozzles are tested with compressed air. Torus nozzles are tested with water. Test procedures require that flow be demonstrated through each individual nozzle.

(4)

Detection of Aging Effects: The periodic drywell and torus spray nozzle flow tests detect plugging by corrosion products from the degradation of carbon steel piping and fittings.

(5)

Monitoring and Trending: The results of the spray nozzle tests are monitored but are not trended. If flow to a nozzle is blocked or restricted the degraded condition is evaluated and corrective actions are taken to restore normal flow.

(6)

Acceptance Criteria: The test procedures contain acceptance criteria that require that flow be observed from and through each individual drywell and torus spray nozzle. The acceptance criteria provide assurance that flow to the drywell and torus spray headers and spray nozzles Is not blocked or restricted.

Dresden and Quad Cities Page B-82 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS (7)

Corrective Actions: If a test shows that flow to a nozzle is blocked or restricted, a condition report is initiated to document the concern in accordance with plant administrative procedures. The degraded condition is evaluated and corrective actions are taken to restore normal flow. The corrective actions program ensures that conditions adverse to quality are promptly corrected. If the deficiency is found to be significantly adverse to quality, the cause of the condition is determined and an action plan is developed to preclude recurrence.

(8)

Confirmation Process: Site quality assurance procedures, review and approval processes, and administrative controls are implemented in accordance with the requirements of 10 CFR Part 50, Appendix B.

(9)

Administrative Controls: See Item 8, above.

(10)

Operating Experience: Dresden has not detected any degradation of the drywell and torus spray headers or spray nozzles. Quad Cities has experienced two events in which foreign material was found in the spray nozzles. In 1998, small amounts of rust were found in some nozzles after a flow test. However, the small amounts of rust found did not pose a blockage problem. In 2000, a V X 3' block of wood was found lodged in a spray nozzle subsequent to a spray test, but this was a foreign material exclusion problem unrelated to aging. No rust was found in the spray nozzles during the 2000 test.

The Dresden and Quad Cities operating experience demonstrates that the periodic flow tests effectively manage drywell and torus spray header and spray nozzle plugging by corrosion products, so that the intended function of providing a quenching spray will be maintained during the period of extended operation.

Conclusion The periodic drywell and torus spray nozzle flow tests effectively manage drywell and torus spray header and spray nozzle plugging by corrosion products. The program provides reasonable assurance that intended functions are maintained consistent with the current licensing basis during the period of extended operation.

Dresden and Quad Cities Page B-83 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.2.5 Lubricating Oil Monitoring Activities Description The lubricating oil monitoring activities manage loss of material and cracking in lubricating oil heat exchangers in the scope of license renewal. These activities include measures to minimize corrosion and to mitigate loss of material and cracking in heat exchangers by monitoring lubricating oil properties.

Sampling, testing, and trending verify lubricating oil properties and ensure that the intended functions of the heat exchangers are not lost. Oil analysis permits identification of specific wear mechanisms, contamination, and oil degradation within operating machinery.

The activities manage physical and chemical properties in lubricating oil. The complete aging management program for lubricating oil heat exchangers also includes secondary side (heat sink) chemistry controls, performance monitoring, and inspections. Those portions of the lubricating oil heat exchanger management program are described in:

Section B.1.14, Closed-Cycle Cooling Water System, for the diesel generator and station blackout diesel generator oil coolers; and in Section B.2.6, Heat Exchanger Test and Inspection Activities, for the HPCI oil coolers.

Evaluation and Technical Basis (1)

Scope of Activity: The following lubricating oil heat exchangers are subject to this program:

Dresden Unit 2 and 3 HPCI lubricating oil coolers Dresden Unit 2, 3 and 2/3 diesel generator lubricating oil coolers Dresden Units 2 and 3 station blackout (SBO) diesel generator lubricating oil coolers Quad Cities Unit 1 and 2 HPCI lubricating oil coolers Quad Cities Unit 1, 2, and 1/2 diesel generator lubricating oil coolers Quad Cities Unit I and 2 station blackout (SBO) diesel generator lubricating oil coolers (2)

Preventive Actions: Monitoring and control of oil Impurities and properties mitigates loss of material and cracking in lubricating oil systems.

(3)

Parameters Monitored/inspected: The program includes specifications for known oil degradation indicators and degradation characteristics, sampling and analysis frequencies, and corrective actions for control of lubricating oil properties. Lubricating oil physical properties are tested to standard ASTM and ISO methods, for the applicable oil type, to provide accurate quantitative numbers with repeatable results. Samples are Dresden and Quad Cities Page B-84 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS taken monthly for emergency diesel generators, and quarterly for HPCI and SBO diesel generators.

Surveillance testing and operational surveillances verify proper heat exchanger performance to support associated system operability.

Oil is analyzed for indications of degraded chemical and physical properties depending on oil type and type of service. Analyses include:

Chemical parameters and viscosity, total acid number, total base number, rotary bomb oxidation test, water demulsability, particle count, fuel and combustion by products, sediment, water, anti-foaming characteristics, whole particle counting, air release and emission spectrum.

Normal, alert, and fault levels for oil chemical and physical properties, wear metals, contaminants, and additives are established for the specific oil type and application.

(4)

Detection of Aging Effects: Monitoring activities maintain lubricating oil properties within predefined limits to both mitigate and detect the effects of aging. Oil analysis has become an accurate method for identifying specific wear mechanisms, contamination, and oil degradation characteristics within operating machinery.

The program includes normal, alert, and fault action levels for oil chemical and physical properties, wear metals, contaminants, and additives, for the specific oil type and application. Increased impurities and degradation of oil properties indicate degradation of materials in lubricating oil systems. Monitoring of the diagnostic parameters indicates degradation due to aging effects prior to loss of intended function.

Samples are taken monthly for emergency diesel generators, and quarterly for HPCI and SBO diesel generators.

Sampling frequency is increased if plant and equipment operating conditions indicate a need to do so.

(5)

Monitoring and Trending: See Items 3 and 4, above for parameters and frequencies. The lubricating oil analysis results are evaluated for acceptability, and are trended and evaluated using computer software and a database.

(6)

Acceptance Criteria: Normal, alert, and fault levels have been established for the various chemical and physical properties, wear metals, additives, and contaminant levels based on information from oil manufacturers, equipment manufacturers, and industry guidelines, for the specific oil type and application. The program maintains contaminant and parameter limits within the application-specific limits. The procedures outline potential actions to be taken at alert and fault levels, and actions can be chosen based on the level of deviation. Aging effects or unacceptable results are evaluated and appropriate corrective actions are taken.

(7)

Corrective Actions: Lubricating oil chemical and physical test results or contaminants outside the allowable limits are returned to the acceptable range within reasonable time periods as identified in industry guidelines. Evaluations are performed for test or inspection results that do not satisfy established criteria and a condition report is initiated to document the concern in accordance with plant administrative procedures.

The corrective actions program ensures that conditions adverse to quality are promptly corrected. If the deficiency Is found to be significantly adverse to quality, the cause of the condition is determined and an action plan is developed to preclude recurrence.

Dresden and Quad Cities Page B-85 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS (8)

Confirmation Process: Site quality assurance procedures, review and approval processes, and administrative controls are implemented in accordance with the requirements of 10 CFR Part 50, Appendix B.

(9)

Administrative Controls: See Item 8, above.

(10)

Operating Experience: The overall effectiveness of lubricating oil monitoring activities is indicated by the Dresden and Quad Cities operating experience. Lubricating oil sampling and analysis have detected particulate or water contamination (or both) in lubricating oil systems. In some cases these events resulted in systems being declared inoperable until repaired, and until the oil was flushed or replaced. Operating experience has produced procedure and program changes, which have improved the effectiveness of lubricating oil testing and inspection activities.

Conclusion The lubricating oil preventive, inspection, and testing activities mitigate, detect, monitor, and trend the effects of loss of material and cracking in lubricating oil coolers. The program provides reasonable assurance that intended functions are maintained consistent with the current licensing basis during the period of extended operation.

Page B-86 Dresden and Quad Cities License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.2.6 Heat Exchanger Test and Inspection Activities Description The heat exchanger test and inspection activities provide condition monitoring, inspection, and performance testing. The activities manage loss of material, cracking, and buildup of deposits in heat exchangers in the scope of license renewal that are not tested and inspected by the Open-Cycle Cooling Water System (B.1.13) and Closed Cycle Cooling Water System (B.1.14) aging management programs. The augmentation activities identified in NUREG-1801, lines IV.CI.4-a and IV.CI.4-b to manage loss of material and cracking for the Dresden isolation condensers are included in this aging management program.

The heat exchanger test and inspection activities are new and will be implemented prior to the period of extended operation.

Surveillance testing verifies that heat exchanger performance is adequate to support system operability requirements.

Inspections and in-service nondestructive examinations (ISI, NDE) detect aging effects. Tests and inspections, and monitoring and trending of test results, confirm that aging effects are managed and that system and component functions are maintained.

The isolation condenser test and inspection augmentation activities detect cracking due to stress corrosion cracking or cyclic loading, and detect loss of material due to pitting and crevice corrosion. These augmentation activities are not part of the ISI program, but verify that the ISI program is effective for ensuring that significant degradation is not occurring, and therefore that the intended function of the isolation condenser is maintained during the extended period of operation.

These augmentation activities consist of temperature and radioactivity monitoring of the shell-side (cooling) water, and eddy current testing of tubes.

The inservice inspection, water chemistry management and lubricating oil management activities applied to the heat exchangers in the scope of this aging management program are described in the following program evaluations.

The inservice inspection Is described in the ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD (B.1.1) aging management program.

Management of water chemistry is described in the Water Chemistry (B.1.2) aging management program.

Management of oil properties for the HPCI lubricating oil coolers is described in the Lubricating Oil Monitoring Activities (B.2.5) plant-specific aging management program.

Dresden and Quad Cities Page B-87 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Evaluation and Technical Basis (1)

Scope of Activity: The following heat exchangers are subject to these test and inspection activities:

Dresden Unit 2 and 3 HPCI lubricating oil coolers a

Dresden Unit 2 and 3 HPCI gland seal condensers a

Dresden main control room air handling unit heat exchanger 0

Dresden Unit 2 and 3 isolation condensers Quad Cities Unit 1 and 2 HPCI lubricating oil coolers Quad Cities Unit 1 and 2 HPCI gland seal condensers Quad Cities main control room air handling unit heat exchanger Quad Cities Unit I and 2 battery/station blackout room HVAC heat exchangers (2)

Preventive Actions: These heat exchanger test and inspection activities do not provide any preventive actions. These activities provide condition monitoring to detect degradation prior to a loss of function.

(3)

Parameters Monitored/Inspected: Performance tests verify system operability by verifying proper fluid flows, or temperatures, or differential pressures during system operation under load. Inspection activities monitor the effects of corrosion and buildup of deposits. Periodic inspections and NDE tests may consist of visual inspections, eddy current testing, and ultrasonic tests or radiography to detect loss of material, cracking, or buildup of deposits.

Temperature and radioactivity are monitored in the Dresden isolation condenser shell side water. Temperature monitoring of the Dresden isolation condenser is accomplished through proceduralized operational checks.

Radioactivity monitoring of the Dresden isolation condenser is through periodic sampling.

(4)

Detection of Aging Effects: Loss of material, cracking, or buildup of deposits would result in degradation of heat exchanger or system performance. The frequency and extent of inspections and testing ensure detection of aging effects before the loss of intended function of the heat exchanger or associated system. Heat removal capabilities are generally verified by performing system operability testing.

Heat exchanger inspections are generally conducted at 10-year intervals or less. Shorter intervals are based on industry guidelines or plant operating experience. Eddy current testing is to be performed at least once every 10 years, and the procedure provides for increasing the inspection frequency based on the indications.

After initial inspection, subsequent inspection frequencies will be based on the as-found condition of the equipment. The inspection and testing intervals may be adjusted on the basis of the results of the reliability analysis, type of service, frequency of operation, or age of components and systems.

Dresden and Quad Cities Page B-88 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS Temperature and radioactivity monitoring of the Dresden isolation condenser shell side water will detect tube-to-shell-side leaks.

(5)

Monitoring and Trending: Heat transfer testing results are documented in plant test procedures, and trended and reviewed by the appropriate group.

Isolation condenser temperatures are recorded in the operator's surveillance log.

Radiation monitoring of the isolation condensers is conducted by procedure.

(6)

Acceptance Criteria: Specific acceptance criteria are provided in the inspection or test procedures, as required to ensure continued system and component operability.

System functional testing must confirm the systems' ability to meet minimum Technical Specification requirements. EPRI guidance is used to determine allowable percent wall loss and plugging criteria, and for projections of remaining life.

Indications of degradation are evaluated to determine if the material condition will maintain the system intended function prior to returning the system to operable status.

Engineering evaluations are performed if evidence of aging is found, and determine if there is a need to alter fluid chemistry, replace tubing, or impose an additional aging management activity.

(7)

Corrective Actions: See Item 6, above. Evaluations are performed for test or inspection results that do not satisfy established criteria and a condition report is initiated to document the concern in accordance with the corrective action program.

The corrective action program ensures that conditions adverse to quality are promptly corrected. If the deficiency is found to be significantly adverse to quality, the cause of the condition is determined and an action plan is developed to preclude recurrence.

(8)

Confirmation Process: Site quality assurance procedures, review and approval processes, and administrative controls are implemented in accordance with the requirements of 10 CFR Part 50, Appendix B.

(9)

Administrative Controls: See Item 8, above.

(10)

Operating Experience: This is a new aging management program. No program operating experience exists at this time. However, similar controls implemented for the GL 89-13, "Service Water System Problems Affecting Safety-Related Equipment,"

program have been effective in detecting aging effects in heat exchangers. Instances of loss of material, cracking, and buildup of deposits in heat exchangers have been detected in Dresden and Quad Cities heat exchangers prior to loss of system intended functions.

Conclusion The method, extent and schedule of these heat exchanger inspection and test activities provide reasonable assurance that loss of material, cracking, and buildup of deposits in heat exchangers would be detected prior to loss of their intended function. The program provides reasonable assurance that intended functions are maintained consistent with the current licensing basis during the period of extended operation.

Dresden and Quad Cities Page B-89 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS B.2.7 Generator Stator Water Chemistry Activities (Quad Cities Only)

Description Quad Cities generator stator water chemistry activities manage aging by monitoring and controlling water chemistry per established procedures.

Evaluation and Technical Basis (1)

Scope of Activity: Stator cooling water is continuously monitored for purity by a conductivity cell. The conductivity cell annunciates an alarm if conductivity increases to a predetermined limit.

Water chemistry is maintained in accordance with General Electric guidelines for stator cooling water systems. The system is equipped with a resin bed that continuously filters a portion of the system flow.

(2)

Preventive Actions: Stress corrosion cracking (SCC) of stator cooling water components is unlikely as contaminants are maintained at very low levels, in accordance with General Electric guidelines, and the system is normally operated at temperatures less than 1400F. Quad Cities procedures provide a feed-and-bleed operation if the dissolved oxygen concentration approaches predetermined limits.

(3)

Parameters Monitored/Inspected: Periodic sampling is not necessary as water conductivity is continuously monitored to ensure purity. Quad Cities procedures provide for periodically logging of water chemistry data.

(4)

Detection of Aging Effects: This program mitigates loss of material aging effects. It is not credited for detection of aging effects.

(5)

Monitoring and Trending: See item 3, above.

(6)

Acceptance Criteria: See item 2, above.

(7)

Corrective Actions: Corrective actions are taken for water chemistry parameters outside the General Electric guidelines in order to restore chemistry within acceptable parameters. Evaluations are performed for test results that do not satisfy established criteria, and a condition report is initiated to document the concern in accordance with plant administrative procedures.

The corrective action program ensures that conditions adverse to quality are promptly corrected. If the condition is significantly adverse to quality, the cause of the condition is determined and an action plan is developed to preclude recurrence.

(8)

Confirmation Process: Stator cooling water is continuously analyzed.

Additional sampling is therefore not required following corrective actions. Site quality assurance procedures, review and approval processes, and administrative controls are implemented in accordance with the requirements of 10 CFR Part 50, Appendix B.

(9)

Administrative Controls: See Item 8, above.

(10)

Operating Experience: No age-related degradation of stator cooling water system components, within the scope of license renewal, has been observed.

The Dresden and Quad Cities Page B-90 License Renewal Application

Appendix B AGING MANAGEMENT PROGRAMS current water chemistry activities have proven effective in managing aging of the stator cooling water system components. The current chemistry activities therefore require no enhancements.

Conclusion The Quad Cities generator stator water chemistry program provides reasonable assurance that intended functions of the Quad Cities stator cooling water system components within the scope of license renewal are maintained consistent with the current licensing basis during the period of extended operation.

Dresden and Quad Cities Page B-91 License Renewal Application

Table of Contents APPENDIX C COMMODITY GROUPS (Not Used)

Dresden and Quad Cities License Renewal Application

Table of Contents APPENDIX D TECHNICAL SPECIFICATION CHANGES (Not Used)

Dresden and Quad Cities License Renewal Application

Table of Contents APPENDIX E ENVIRONMENTAL INFORMATION FOR DRESDEN NUCLEAR POWER STATION (Provided under separate cover)

Dresden and Quad Cities License Renewal Application

Table of Contents APPENDIX F ENVIRONMENTAL INFORMATION FOR QUAD CITIES NUCLEAR POWER STATION (Provided under separate cover)

Dresden and Quad Cities License Renewal Application