MONTHYEARNLS2024006, Response to Nuclear Regulatory Commission'S Request for Additional Information for Relief Request RC3-022024-01-25025 January 2024 Response to Nuclear Regulatory Commission'S Request for Additional Information for Relief Request RC3-02 NLS2024007, Emergency Plan Implementing Procedure 5.7.1, Revision 732024-01-16016 January 2024 Emergency Plan Implementing Procedure 5.7.1, Revision 73 NLS2024003, 30 Day Report - Unauthorized Disassembly of Liquid Scintillation Detector2024-01-15015 January 2024 30 Day Report - Unauthorized Disassembly of Liquid Scintillation Detector NLS2024004, Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 20232024-01-10010 January 2024 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 2023 NLS2023053, ISFSI, Supplement to Exemption Request from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-11-30030 November 2023 ISFSI, Supplement to Exemption Request from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation NLS2023050, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-11-22022 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation NLS2023045, Application to Revise Technical Specifications to Adopt TSTF-374, Revision to Diesel Fuel Oil Testing Program2023-11-15015 November 2023 Application to Revise Technical Specifications to Adopt TSTF-374, Revision to Diesel Fuel Oil Testing Program NLS2023051, Response to Nuclear Regulatory Commission Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2023-10-10010 October 2023 Response to Nuclear Regulatory Commission Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements NLS2023049, 10 CFR Part 21 Report Regarding HGA Relays2023-09-0606 September 2023 10 CFR Part 21 Report Regarding HGA Relays NLS2023029, License Amendment Request to Revise Technical Specifications to Support Inspection of Diesel Fuel Oil Storage Tanks2023-09-0606 September 2023 License Amendment Request to Revise Technical Specifications to Support Inspection of Diesel Fuel Oil Storage Tanks NLS2023047, Licensee Guarantees of Payment of Deferred Premiums2023-07-26026 July 2023 Licensee Guarantees of Payment of Deferred Premiums NLS2023033, 10 CFR 50.55a Relief Request RC3-022023-06-27027 June 2023 10 CFR 50.55a Relief Request RC3-02 NLS2023039, Preparation and Scheduling of Operator Licensing Examinations2023-06-0101 June 2023 Preparation and Scheduling of Operator Licensing Examinations NLS2023038, Nebraska Public Power District 2022 Financial Report2023-05-22022 May 2023 Nebraska Public Power District 2022 Financial Report NLS2023031, Annual Radiological Environmental Report2023-05-11011 May 2023 Annual Radiological Environmental Report NLS2023017, Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2023-05-0303 May 2023 Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements NLS2023018, Application to Revise Technical Specifications to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling2023-05-0303 May 2023 Application to Revise Technical Specifications to Adopt TSTF-580, Provide Exception from Entering Mode 4 with No Operable RHR Shutdown Cooling NLS2023030, Annual Radioactive Effluent Release Report2023-04-27027 April 2023 Annual Radioactive Effluent Release Report NLS2023007, Technical Specification Bases Changes2023-04-17017 April 2023 Technical Specification Bases Changes NLS2023027, Annual Report of Individual Exposure Monitoring2023-04-13013 April 2023 Annual Report of Individual Exposure Monitoring NLS2023021, Quality Assurance Program Changes2023-04-10010 April 2023 Quality Assurance Program Changes NLS2023020, Decommissioning Funding2023-03-29029 March 2023 Decommissioning Funding NLS2023019, Property Insurance Coverage2023-03-23023 March 2023 Property Insurance Coverage NLS2023010, Inservice Inspection OAR-1 Owner'S Activity Report for Cooper Nuclear Station2023-02-0909 February 2023 Inservice Inspection OAR-1 Owner'S Activity Report for Cooper Nuclear Station NLS2023005, Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 20222023-01-19019 January 2023 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 2022 NLS2022054, Preparation and Scheduling of Operator Licensing Examinations2023-01-0505 January 2023 Preparation and Scheduling of Operator Licensing Examinations NLS2022055, Emergency Plan, Revision 812023-01-0404 January 2023 Emergency Plan, Revision 81 NLS2022053, CNS-2022-11 Post Exam Submittal2022-11-22022 November 2022 CNS-2022-11 Post Exam Submittal NLS2022050, Notification of Revision to Cooper Nuclear Station Emergency Response Data System Data Point Library2022-11-0909 November 2022 Notification of Revision to Cooper Nuclear Station Emergency Response Data System Data Point Library NLS2022048, Management Change and Correspondence Update2022-11-0101 November 2022 Management Change and Correspondence Update NLS2022047, Core Operating Limits Report, Cycle 33, Revision 02022-10-14014 October 2022 Core Operating Limits Report, Cycle 33, Revision 0 NLS2022042, 10 CFR 50.59(d)(2) and 10 CFR 72.48(d)(2) Summary Report2022-10-0707 October 2022 10 CFR 50.59(d)(2) and 10 CFR 72.48(d)(2) Summary Report NLS2022037, Emergency Plan, Revision 80, Summary of 50.54(q) Analyses2022-08-18018 August 2022 Emergency Plan, Revision 80, Summary of 50.54(q) Analyses NLS2022035, Evacuation Time Estimate Report for Cooper Nuclear Station2022-08-16016 August 2022 Evacuation Time Estimate Report for Cooper Nuclear Station NLS2022031, Licensee Guarantees of Payment of Deferred Premiums2022-07-19019 July 2022 Licensee Guarantees of Payment of Deferred Premiums NLS2022005, Application to Revise Technical Specifications to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements2022-06-16016 June 2022 Application to Revise Technical Specifications to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements NLS2022025, Nebraska Public Power District Letter (NLS2022010) to U.S. Nuclear Regulatory Commission Dated April 5, 2022, Annual Report of Individual Exposure Monitoring2022-06-0606 June 2022 Nebraska Public Power District Letter (NLS2022010) to U.S. Nuclear Regulatory Commission Dated April 5, 2022, Annual Report of Individual Exposure Monitoring NLS2022016, Annual Radiological Environmental Report2022-05-10010 May 2022 Annual Radiological Environmental Report NLS2022020, Nebraska Public Power District, Cooper Nuclear Station, 2021 Financial Report2022-05-0202 May 2022 Nebraska Public Power District, Cooper Nuclear Station, 2021 Financial Report NLS2022014, Annual Radioactive Effluent Release Report2022-04-27027 April 2022 Annual Radioactive Effluent Release Report NLS2022010, Annual Report of Individual Exposure Monitoring2022-04-0505 April 2022 Annual Report of Individual Exposure Monitoring NLS2022009, Property Insurance Coverage2022-03-23023 March 2022 Property Insurance Coverage NLS2022011, Preparation and Scheduling of Operator Licensing Examinations2022-03-18018 March 2022 Preparation and Scheduling of Operator Licensing Examinations NLS2022004, Response to Nuclear Regulatory Commission'S Request for Additional Information Regarding Relief Request RR5-01, Revision 12022-02-0707 February 2022 Response to Nuclear Regulatory Commission'S Request for Additional Information Regarding Relief Request RR5-01, Revision 1 NLS2022003, Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 20212022-01-20020 January 2022 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models for 2021 NLS2021067, ISFSI - Independent Spent Fuel Storage Installation Decommissioning Funding Plan2021-12-16016 December 2021 ISFSI - Independent Spent Fuel Storage Installation Decommissioning Funding Plan NLS2021069, Withdrawal of Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2021-12-15015 December 2021 Withdrawal of Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements NLS2021066, Response to Nuclear Regulatory Commission'S Request for Additional Information Regarding Alternative Request RI5-02, Revision 32021-12-10010 December 2021 Response to Nuclear Regulatory Commission'S Request for Additional Information Regarding Alternative Request RI5-02, Revision 3 NLS2021065, Clarification of Response to Nuclear Regulatory Commission'S Request for Additional Information for Alternative Request RS-012021-12-0606 December 2021 Clarification of Response to Nuclear Regulatory Commission'S Request for Additional Information for Alternative Request RS-01 NLS2021056, Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements2021-11-16016 November 2021 Application to Revise Technical Specifications to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements 2024-01-25
[Table view] |
Text
H Nebraska Public Power District 50.46 Nebraska's Energy Leader NLS2002088 July 12, 2002 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
Subject:
Reporting of Changes and Errors in ECCS Evaluation Models Cooper Nuclear Station NRC Docket 50-298, DPR-46
Reference:
Letter from J.H. Swailes (Nebraska Public Power District) to U. S. Nuclear Regulatory Commission, dated June 6, 2001, Reporting of Changes and Errors in ECCS Evaluation Models.
In accordance with 10 CFR 50.46(a)(3)(ii), the Nebraska Public Power District (NPPD) is submitting this special report enumerating the impact of changes and errors in the evaluation model used by General Electric (GE) to demonstrate compliance with the Emergency Core Cooling System (ECCS) requirements of 10 CFR 50.46. In the Reference letter, the District provided revisions to the Licensing Basis (LB) Peak Clad Temperatures (PCT) for Cooper Nuclear Station (CNS), in accordance with 10 CFR 50.46(a)(3)(i) and (ii). As a result of two reports of errors identified in the SAFER analyses, NPPD is updating the LB PCT values for CNS. Attachment I summarizes, by fuel type, the baseline PCTs, the PCT error accumulations, and the resultant estimated LB PCTs for the limiting and non-limiting fuel types.
A core spray injection elevation error was found in SAFER. An error was found in the automation code that prepares the input basedecks for the SAFER analysis. This error resulted in too low a value being calculated for the core spray injection elevation for the lower core spray sparger. The injection elevation for the lower sparger was set slightly above the top of the fuel channels (bottom of the lower plenum region in the SAFER code). This error affects the buildup and draining of the pool in the upper plenum. The error also affects the amount of steam quenched by the core spray water. The incorrect injection elevation may result in an incorrect calculation for the PCT.
Because the core spray injection elevation controls several competing phenomena, the effect of correcting the injection elevation may result in an increase or decrease in the PCT. Raising the injection elevation increases the amount of inventory that can be held up in the pool of water that may form in the upper plenum. This inventory holdup may delay the reflooding of the core, which can result in an increase in the PCT. On the other hand, the higher injection elevation results in more steam being condensed by the spray water. The increased condensation can result in a faster vessel depressurization and Cooper Nuclear Station P.O. Box 98/Brownville, NE 68321-0098 Telephone: (402) 825-3811 / Fax: (402) 825-5211 http://www.nppd.com
NLS2002088 Page 2 of 3 higher ECCS flows, which can result in an earlier reflooding of the core and a decrease in the PCT. In addition, the spray water flowing to the lower plenum will be warmer (having condensed more steam). The core may then reflood faster with a more highly voided mixture, again resulting in a decrease in the PCT. The analysis assumptions (nominal or Appendix K) can also affect whether the correction results in an increase or decrease in PCT.
A study was performed to assess the impact of the correction in the core spray injection elevation on the PCT. A set of representative jet pump plants covering the Boiling Water Reactor (BWR)/3-6 product lines was selected, and SAFER runs were performed to obtain the change in PCT for both Nominal and Appendix K conditions. The impact on the PCT ranged from - 95°F to + 60'F. A small break analysis was also performed for both Nominal and Appendix K conditions on a few selected plants. The impact on the PCT was increases of up to +30'F.
The impact of this error for CNS was an increase in the LB PCT of+ 50 F for GE9 fuel and N/A for GE 14 fuel.
Another error in SAFER was found. The initial vessel water level used in some SAFE/REFLOOD and SAFER Loss of Coolant Accident (LOCA) analyses did not properly account for the effect of the steam dryer pressure drop on the initial inventory of water in the vessel. In the LOCA analyses, the initial water level is assumed to be at either normal water level or at the low water level scram (Level 3) analytical limit, depending on the analysis assumptions. The numerical value used in the analysis was based on the level as indicated by the level instrumentation. The indicated level shows the water level in the annular region between the dryer skirt and the vessel wall. The water inside the dryer skirt is at a lower level; the difference between the levels inside and outside the dryer skirt is equivalent to the steam dryer pressure drop. The SAFE and SAFER codes do not model the steam dryer effects on the initial water level. The initial liquid inventory in the vessel is determined by the value of the initial bulk water level input in the SAFE and SAFER codes. Using the indicated water level as the initial water level results in too high an initial liquid inventory because the lower water level inside the dryer skirt is not addressed. This additional water in the vessel assumed in the analysis may delay the core uncovery, which may result in a non-conservative calculation of the PCT.
When corrected for the dryer pressure drop, the initial bulk water level in the vessel is lower than that used in the original SAFE or SAFER analyses. A SAFER evaluation was performed to assess the impact of the correction in the bulk water level on the PCT. A set of representative plants covering the BWR/2-6 product lines was selected and SAFER runs were performed to obtain the change in PCT for both Nominal and Appendix K conditions. The impact on the PCT ranged from -5°F to +20'F. A similar evaluation
NLS2002088 Page 3 of 3 showed that the impact of the error was negligible for plants using the SAFE/REFLOOD methodology.
This error applies to SAFE/REFLOOD and SAFER analyses for BWR/2-6 plants. The impact of this error for CNS was an increase in the LB PCT of+ 10°F for GE9 fuel and N/A for GEl4 fuel.
As shown in Attachment 1, the LB PCT values have more than 300'F margin to the 2200'F limit specified in 10 CFR 50.46. Due to the large margin to the 2200'F limit, no reanalysis is planned at this time.
If you have any questions, please do not hesitate to contact Jerry Lewis at (402) 825 5770.
Sincerely, Michael T. Coyle Site Vice President Attachment cc: Regional Administrator w/attachment USNRC - Region IV Senior Project Manager w/attachment USNRC - NRR Project Directorate IV-I Senior Resident Inspector w/attachment USNRC Records w/attachment
NLS2002088 Attachment I Page 1 of I Current Baseline LB PCT (IF) Values and Error Accumulation Cooper Nuclear Station GE9 GE14 Baseline PCT 1570 1760 Existing Error (Reported +5 N/A 12/23/1999)
Existing Error (Reported -5 N/A 12/28/2000)
Existing Errors (Reported +95 +95 6/6/2001)
GE 10 CFR 50.46 +5 N/A Notification Letter 2002-01 GE 10 CFR 50.46 +10 N/A Notification Letter 2002-01 PCT Error Accumulation 120 95 New Estimated Licensing 1680 1855 Basis PCT Values
ATTACHMENT 3 LIST OF REGULATORY COMMITMENTS Correspondence Number: NLS2002088 The following table identifies those actions committed to by Nebraska Public Power District (NPPD) in this document. Any other actions discussed in the submittal represent intended or planned actions by NPPD. They are described for information only and are not regulatory commitments. Please notify the NL&S Manager at Cooper Nuclear Station of any questions regarding this document or any associated regulatory commitments.
COMMITTED DATE COMMITMENT OR OUTAGE None