MONTHYEARML0205706382002-03-28028 March 2002 Issuance of Amendment Revises the Test Frequency for the Containment Spray Nozzles from Once Per 10 Years to Following Activities That Could Result in Nozzle Blockage Project stage: Approval ML0208805052002-03-28028 March 2002 Tech. Spec. Page for Amendment No. 146, Revising the Test Frequency for the Containment Spray Nozzles from Once Per 10 Years to Following Activities That Could Result in Nozzle Blockage Project stage: Other ML0212606802002-04-26026 April 2002 Submittal of Radiological Environmental Monitoring Report (REMP) for Cy 2001 for Oyster Creek Generating Station Project stage: Request ML0212802222002-05-0707 May 2002 Licensing Actions Project stage: Other ML0214003812002-05-16016 May 2002 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML0213702202002-05-17017 May 2002 Request Conference Call Proposed Amendment Project stage: Other ML0213600052002-06-0404 June 2002 Biweekly Notice Memo, Notice of Issuance of Amendment 151. Amendment Revises Technical Specifications to Be Consistent with Changes Made to 10 CFR 50.59, Changes, Tests, & Experiments Project stage: Approval ML0213600022002-06-0404 June 2002 License Amendment, Revising the Technical Specifications to Be Consistent with Changes Made to 10 CFR 50.59, Changes, Tests, and Experiments Project stage: Other ML0216905712002-06-0404 June 2002 Tech Specs for Amendment No. 151 Revising the Tech Specs to Be Consistent with Changes Made to 10CFR 50.59, Changes, Tests and Experiments Project stage: Other ML0216301202002-06-10010 June 2002 Draft RAI on Your 04/26/02 Amendment Request Project stage: Draft RAI ML0220405862002-07-11011 July 2002 Response to Request for Additional Information - Technical Specification Change Request No. 308 General Electric Stability Analysis Methodology Project stage: Response to RAI ML0219705332002-07-24024 July 2002 Request for Withholding Information from Public Disclosure, Oyster Creek Nuclear Generating Station Project stage: Withholding Request Acceptance ML0222607982002-08-0101 August 2002 Response to Request for Additional Information - Technical Specification Change Request No. 291, Safety Limit Minimum Critical Power Ratio Project stage: Response to RAI ML0221905092002-08-0505 August 2002 Conference Call Re. 04/26/02 Proposed Amend Project stage: Other ML0222609462002-08-20020 August 2002 Second Request for Additional Information Regarding Your April 26, 2002, Application for Amendment Project stage: RAI ML0223501682002-08-23023 August 2002 Site Visit to Address Issues Related to Amendment Application of April 26, 2002 Project stage: Other ML0224203602002-08-30030 August 2002 Withholding from Public, Response to Request for Additional Information - Technical Specification Change Request No. 291, Safety Limit Minimum Critical Power Ratio, MB5505 Project stage: RAI ML0226600972002-09-12012 September 2002 Response to Request for Additional Information - Technical Specification Change Request No. 308, General Electric Stability Analysis Methodology Project stage: Response to RAI ML0225600192002-09-18018 September 2002 Issuance of Amendment Licensed and Non-Licensed Operating Personnel Training Programs Project stage: Approval ML0226302742002-09-18018 September 2002 Oyster Creek,Tech Spec Pages/Amend 232 Project stage: Other ML0226005292002-09-24024 September 2002 License Amendment Revision to TSs Change Request - Clarification of Requirements for Licensed Operator Qualifications & Training Project stage: Approval ML0227005082002-09-24024 September 2002 Tech Spec Pages for Amendment No. 154, Revision to TSs Change Request - Clarification of Requirements for Licensed Operator Qualifications & Training Project stage: Approval ML0226805692002-09-26026 September 2002 Issuance of License Amendment Cycle 19 Safety Limit Minimum Critical Power Ratio Project stage: Approval ML0227005492002-09-26026 September 2002 Tech Spec Pages for Amendment 233 Cycle 19 Safety Limit Minimum Critical Power Ratio Project stage: Other ML0228300432002-10-0909 October 2002 Current TAC List Project stage: Other ML0229103652002-10-18018 October 2002 Issuance of Amendment Use of Option II Solution for Reactor Instability Problem Project stage: Approval ML0229503812002-10-18018 October 2002 Technical Specification Amendment 235 - 2.3 Limiting Safety System Settings Pages 2.3-1, 2.3-2, 2.3-4, 2.3-5, 2.3-6, 3.1-1, 3.1-7, 3.10-2, 3.10-3, and 3.10-4 Project stage: Other RS-03-034, Delegation of Authority of Amergen Energy Company, LLC (Amergen) Nuclear Power Plants2003-02-0606 February 2003 Delegation of Authority of Amergen Energy Company, LLC (Amergen) Nuclear Power Plants Project stage: Other 2002-07-24
[Table View] |
Text
From:
Peter Tam To:
INTernet:David.distel@exeloncorp.com; INTernet:george.rombold@exeloncorp.com; internet:paul.czaya@exelon.com Date:
5/17/02 9:18AM
Subject:
Request conference call re. proposed amendment (TAC MB4960)
Paul, David:
Our reviewer S. V. Athavale would like to discussion the following 3 draft questions in a conference call with AmerGen. These are concerning your application for amendment, M.
Gallagher (AmerGen) to NRC, April 26, 2002, proposed licence amendment to implement BWROG Option II solution to alleviate the long-term reactor stability concern This e-mail does not convey a formal NRC staff position, and does not formally request additional information. The sole purpose of this e-mail is to prepare AmerGen for a proposed conference call.
- 1. The NRC staff believes that digital circuits of the new FCTR cards may have embedded software or firmware that is built and programmed for the dedicated task(s). If this is true, then please confirm that the embedded software is fully testable and meets the required quality. If it does not, then please confirm that the process for an appropriate verification and validation (V&V) was established and performed in accordance with the requirements of IEEE 7-4.3.2 and RG 1.152.
Please confirm that AmerGen has procedures in place to maintain software configuration control.
Since these cards are being installed under 10 CFR 50.59, please provide a copy of your 10 CFR 50.59 evaluation for this design change.
- 2. Please confirm that electromagnetic interference (EMI)/ radio frequency interference (RMI) susceptibility qualification of the new digital FCTR cards was determined based on guidance of EPRI Report TR-102323, and the new hardware will not become a source of conducted and/or radiated EMI and RFI for other safety-related circuits.
- 3. Please confirm that your in-house setpoint calculation methodology was previously reviewed and approved by the NRC staff. If this is not the case, please confirm that your in-house setpoint calculation methodology is based on NRC-approved Industry standards.
Peter S. Tam, Senior Project Manager Project Directorate I-1 Division of Licensing Project Management Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 CC:
Shashikant Athavale
Mail Envelope Properties (3CE50326.501 : 10 : 20510)
Subject:
Request conference call re. proposed amendment (TAC MB4960)
Creation Date:
5/17/02 9:18AM From:
Peter Tam Created By:
PST@nrc.gov Recipients Action Date & Time David Transferred 05/17/02 09:18AM distel (INTernet:David.distel@exeloncorp.
george Transferred 05/17/02 09:18AM rombold (INTernet:george.rombold@exelonco paul Transferred 05/17/02 09:18AM czaya (internet:paul.czaya@exelon.com) nrc.gov owf2_po.OWFN_DO Delivered 05/17/02 09:18AM SVA1 CC (Shashikant Athavale)
Opened 05/17/02 09:44AM Post Office Delivered Route David INTernet:exeloncorp.
com george INTernet:exeloncorp.
com paul internet:exeloncorp.c om owf2_po.OWFN_DO 05/17/02 09:18AM nrc.gov Files Size Date & Time MESSAGE 3237 05/17/02 09:18AM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard Reply Requested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard To Be Delivered:
Immediate Status Tracking:
Delivered & Opened