Text

AmerGen, AmerGen Energy Company, LLC Oyster Creek US Route 9 South P.O. Box 388 Forked River, NJ o8731-o388 An Exelon/British Energy Company 10 CFR 50.36(a)(2)

February 26, 2002 2130-02-20069 United States Nuclear Regulatory Commission Document Control Desk Washington DC 20555

Subject:

Oyster Creek Generating Station Docket 50-219 2001 Annual Radioactive Effluent Release Report Attached is a copy of the Oyster Creek Generating Station Annual Radioactive Effluent Release Report for the period January 1 through December 31, 2001. This submittal is being made in accordance with 10 CFR 50.36(a)(2) and Technical Specification 6.9.1.d.

If any further information or assistance is required, please contact Mr. John Rogers of my staff at 609.971.4893.

Very truly yours, RoJei esiden t

Oyster Creek Generating Station RJD/JJR Enclosure cc:

Administrator, Region I NRC Senior Project Manager NRC Senior Resident Inspector Chief, Bureau of Nuclear Engineering, NJ Department of Environmental Protection

2001 Annual Radioactive Effluent Release Report Oyster Creek Generating Station AmerGen Energy Company

TABLE OF CONTENTS TABLE OF CONTENTS LIST OF TABLES ii EXECUTIVE

SUMMARY

1 YEAR 2001 EVENT REPORT 4

SUPPLEMENTAL INFORMATION 5

i

LIST OF TABLES TABLE 1

ANNUAL OFFSITE DOSES DUE TO RADIONUCLIDES IN EFFLUENTS 3

1A GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES 7

1B GASEOUS EFFLUENTS - ELEVATED RELEASES 8

iC GASEOUS EFFLUENTS - GROUND-LEVEL RELEASES 9

2A LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES 10 2B LIQUID EFFLUENTS 11 3A SOLID WASTE AND IRRADIATED FUEL SHIPMENTS -

SUMMARY

12 3B SOLID WASTE AND IRRADIATED FUEL SHIPMENTS 13 4A HOURS AT EACH WIND SPEED AND DIRECTION 23 4B CLASSIFICATION OF ATMOSPHERIC STABILITY 39 ii

EXECUTIVE

SUMMARY

AMERGEN ENERGY COMPANY OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2001 THROUGH DECEMBER 31, 2001 This report summarizes the radioactive liquid and gaseous effluents from the Oyster Creek Generating Station and the calculated maximum hypothetical radiation exposure to the public resulting from those effluents. This report covers the period of operation from January 1, 2001 through December 31, 2001.

Radioactive gaseous releases from the plant are monitored by radiation monitors and filtering systems installed in the plant stacks. Regarding liquid releases, representative samples are collected and analyzed prior to discharge. These methods accurately determine the types and quantities of radioactive materials being released to the environment.

Utilizing gaseous effluent data, the maximum hypothetical dose to any individual in the vicinity of the plant was calculated using a mathematical model, which is based on the methods defined by the U.S. Nuclear Regulatory Commission.

There was no dose attributable to liquid effluents because there were no liquid radioactive releases from the facility in 2001.

The maximum hypothetical doses are conservative overestimates of the actual off-site doses, which are likely to occur. For example, wet deposition due to precipitation events decreases the off-site dose, but this phenomenon is not incorporated into the mathematical dose model.

Radioactive airborne discharges from the facility during 2001 consisted of 394 curies of noble gases, 3.82E-2 (0.0382) curies of radioiodines, 5.57E-2 (0.0557) curies of particulate activity, and 27.9 curies of tritium.

Fifty-one (51) solid, low level radioactive waste shipments, totaling approximately 1943 cubic meters, were shipped from the Oyster Creek Generating Station during the reporting period. This material went to either a licensed burial site or to a waste processor for volume reduction. Dewatering was used in lieu of solidification of resins and filter sludge.

The maximum hypothetical calculated organ dose (bone) to any individual due to gaseous effluents (0.216 mrem/year) was approximately 1.44 percent of the annual limit (Table 1).

The maximum hypothetical calculated whole body dose to any individual due to gaseous effluents (5.69E-3 mrem/year) was 1.14 E-3 percent of the annual limit.

1

The total maximum hypothetical organ dose (bone) of 2.21E-1 mrem/year received by any individual from gaseous effluents from the Oyster Creek Generating Station for the reporting period is over 1350 times lower than the dose the average individual in the Oyster Creek area received from natural background radiation, including that from radon (300 mrem) during the same time period.

The natural background radiation dose averages approximately 100 mrem whole body per year in the Central New Jersey area. In addition, the average equivalent dose to the whole body from naturally occurring radon is about 200 mrem per year.

2

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 1 ANNUAL OFFSITE DOSES DUE TO RADIONUCLIDES IN EFFLUENTS January 1, 2001 through December 31, 2001 Reference ODCM ODCM ODCM ODCM ODCM ODCM ODCM ODCM 4.6.1.1.4.A 4.6.1.1.4.A 4.6.1.1.5.A 4.6.1.1.5.A 4.6.1.1.5.B 4.6.1.1.6.A 4.6.1.1.6.A 4.6.1.1.7.A Liquid Liquid Noble Gas Noble Gas H-3, Iodines, &

Noble Gas Noble Gas 1-131, 1-133, &

Total Body GI Tract Total Body Skin Particulates Gamma Dose Beta Dose Particulates Bone Bone mrem mrem mrem mrem mrem mRad mRad mrem ODCM 3.0 mrem/year 10.0 mrem/year 500 mrem/year 3000 mrem/year 1500 mrem/year 10 mRad/year 20 mRad/year 15 mrem/year Limit 0.OOE+00*

0.OOE+00*

5.69E-03 9.15E-03 2.16E-01 1.91E-02 1.81E-02 2.16E-01 2001 Dose mrem mrem mirem mrem mrem mrem mrem mrem Percent 0.OOE+O0*

0.00E+00*

1.14E-03 3.05E-04 1.44E-02 1.91E-01 9.05E-02 1-44E+00 of Limit Percent Percent Percent Percent Percent Percent Percent Percent Reference ODCM ODCM 4.6.1.1.8.A 4.6.1.1.8.A All Effluents All Effluents Bone Thyroid mrem mrem ODCM 25 mrem/year 75 mrem/year Limit 2.21 E-01 1.23E-01 2001 Dose mrem mrem Percent 8.84E-01 1.64E-01 of Limit Percent Percent 1* No liquid releases were made from the OCGS dunn 2001 3

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2001 THROUGH DECEMBER 31, 2001 YEAR 2001 EVENT REPORT LIQUID EFFLUENT RELEASES There were no liquid radioactive releases from the facility in 2001.

CHANGES TO THE OFFSITE DOSE CALCULATION MANUAL One revision to the Oyster Creek Generating Station Offsite Dose Calculation Manual (ODCM) was made during the reporting period. This change involved abandoning the Radwaste Overboard Discharge Radiation Monitoring System after the Overboard Discharge Pipe was abandoned and capped. This revision to the ODCM became effective in March 2001.

EFFLUENT MONITORS OUT OF SERVICE GREATER THAN 30 DAYS The following effluent monitor was out of service for greater than thirty days:

The Augmented Offgas Building Vent Radiation Monitor was not calibrated and therefore out-of-service from January 1, 2001 to October 16, 2001. Prioritization deficiencies, due to programmatic failures, was the cause as identified in CAP # 2001-1881. Procedure changes were made to prevent recurrence.

CHANGES TO THE PROCESS CONTROL PLAN There were no changes to the Process Control Plan (PCP) during 2001.

4

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 SUPPLEMENTAL INFORMATION Facility: Oyster Creek Generating Station Licensee: AmerGen Energy Company, L.L.C.

1. Regulatory Limits
a. Fission and activation gases:

Technical Specification 3.6.E. 1:

The gross radioactivity in noble gases discharged from the main condenser air ejector shall not exceed 0.2 l/E Ci/sec after the holdup line where E is the average gamma energy (Mev per atomic transformation).

ODCM 4.6.1.1.5.A The dose equivalent rate in the UNRESTRICTED AREA due to radioactive noble gas in gaseous effluent shall not exceed 500 mrem/year to the total body or 3000 mrem/year to the skin.

Note: The total body dose limit of 500 mrem/year has been superseded by 10 CFR 20.1301.a. I which states:

The total effective dose equivalent to individual members of the public from the licensed operation does not exceed 0.1 rem (1 millisievert) in a year, exclusive of the dose contributions from background radiation, from any medical administration the individual has received, from exposure to individuals administered radioactive material and released in accordance with Sec. 35.75, from voluntary participation in medical research programs, and from the licensee's disposal of radioactive material into sanitary sewerage in accordance with Section 20.2003.

ODCM 4.6.1.1.6.A The air dose in the UNRESTRICTED AREA due to noble gas released in gaseous effluent shall not exceed:

5 mRad/calendar quarter due to gamma radiation 10 mRad/calendar quarter due to beta radiation 10 mRad/calendar year due to gamma radiation, or 20 mRad/calendar year due to beta radiation.

ODCM 4.6.1.1.8.A The annual dose to a MEMBER OF THE PUBLIC due to radioactive material in effluent from the OCNGS in the Unrestricted Area shall not exceed 75 mrem to his/her thyroid or 25 mrem to his/her total body or to any other organ.

b. Iodines ODCM 4.6.1.1.5.B.

The dose equivalent rate in the UNRESTRICTED AREA due to tritium (H-3), 1-131, 1-133, and to radioactive material in particulate form having half-lives of 8 days or more in gaseous effluents shall not exceed 1500 mremryear to any body organ when the dose rate due to H-3, Sr-89, Sr-90, and alpha-emitting radionuclides is averaged over no more than 3 months and the dose rate due to other radionuclides is averaged over no more than 31 days.

ODCM 4.6.1.1.7.A.

The dose to a MEMBER OF THE PUBLIC from 1-131, 1-133, and from radionuclides in particulate form having half-lives of 8 days or more in gaseous effluent, in the UNRESTRICTED AREA shall not exceed 7.5 mrem to any body organ per calendar quarter or 15 mrem to any body organ per calendar year.

c. Particulates, half-lives > 8 Days:

ODCM 4.6.1.1.5.B.

The dose equivalent rate in the UNRESTRICTED AREA due to tritium (H-3), 1-131, 1-133, and to radioactive material in particulate form having half-lives of 8 days or more in gaseous effluents shall not exceed 1500 mrem/year to any body organ when the dose rate due to H-3, Sr-89, Sr-90, and alpha-emitting radionuclides is averaged over no more than 3 months and the dose rate due to other radionuclides is averaged over no more than 31 days.

ODCM 4.6.1.1.7.A.

The dose to a MEMBER OF THE PUBLIC from 1-131, 1-133, and from radionuclides in particulate form having half-lives of 8 days or more in gaseous effluent, in the UNRESTRICTED AREA shall not exceed 7.5 mrem to any body organ per calendar quarter or 15 mrem to any body organ per calendar year.

d. Liquid effluents:

ODCM 4.6.1.1.3.A.

The concentration of radioactive material, other than noble gases, in liquid effluents in the discharge canal at the U.S. Route 9 bridge shall not exceed 10 times the Liquid Effluent Concentrations specified in 10 CFR Part 20.1001-20.2401, Appendix B, Table II, Column 2.

ODCM 4.6.1.1.3.B.

The concentration of noble gases dissolved or entrained in liquid effluent in the discharge canal at the U.S. Route 9 bridge shall not exceed 2.0e-4 u Ci/ml.

ODCM 4.6.1.1.4.A.

The dose to a MEMBER OF THE PUBLIC due to radioactive material in liquid effluent in the UNRESTRICTED AREA shall not exceed:

1.5 mrem to the Total Body during any calendar quarter, 5.0 mrem to any body organ during any calendar quarter, 3.0 mrem to the Total Body during any calendar year, or 10.0 mrem to any body organ during any calendar year.

ODCM 4.6.1.1.8.A The annual dose to a MEMBER OF THE PUBLIC due to radioactive material in effluents from the OCNGS in the Unrestricted Area shall not exceed 75 mrem to his/her thyroid or 25 mrem to his/her total body or to any other organ.

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 SUPPLEMENTAL INFORMATION

2. Maximum Permissible Concentrations MPCs used in determining allowable release rates or concentrations:
a. Fission and activation gases:

Per OCGS ODCM limits, no MPCs are used to calculate allowable fission and activation gas release rates or concentrations.

b. lodines:

Per OCGS ODCM limits, no MPCs are used to calculate allowable iodine gaseous release rates or concentrations.

c. Particulates, half-lives > 8 Days:

Per OCGS ODCM limits, no MPCs are used to calculate allowable particulate gaseous release rates or concentrations.

d. Liquid effluents:

The MPC for Tritium (H-3) is I E-3 u Ci/ml.

3. Average Energy The average energy (E) of the radionuclide mixture in releases of fission and activation gases:

First Quarter:

5.07E-01 Mev (gamma - elevated release)

Second Quarter:

8.22E-01 Mev (gamma - elevated release)

Third Quarter:

2.48E-01 Mev (gamma - elevated release)

Fourth Quarter:

4.31E-01 Mev (gamma - elevated release)

Annual:

6.22E-01 Mev (gamma - elevated release)

4. Measurements and Approximations of Total Radioactivity The methods used to measure or approximate the total radioactivity in effluents and the methods used to determine radionuclide composition:
a. Fission and activation gases:
1. Stack - A continuous recording of gross radioactivity and the incorporation of isotopic data obtained from a weekly grab sample analyzed using gamma spectroscopy.
2. Augmented Offgas (AOG) Vent - The continuous recording of gross activity and the incorporation of isotopic data obtained from a monthly grab sample analyzed using gamma spectroscopy.
3. Turbine Building Stack and Feedpump Room Vent - The continuous recording of gross activity and the incorporation of isotopic data obtained from a monthly grab sample analyzed using gamma spectroscopy
b. Iodines:
1. Stack - Filters are changed weekly and analyzed using gamma spectroscopy.
2. Augmented Offgas (AOG) Vent - Filters are changed weekly and analyzed using gamma spectroscopy.
3. Turbine Building Stack and Feedpump Room Vent - Filters are changed weekly and analyzed using gamma spectroscopy.
c. Particulates:
1. Stack - Filters are changed weekly and analyzed using a low background beta counter and gamma spectroscopy.
2. Augmented Offgas (AOG) Vent - Filters are changed weekly and analyzed using gamma spectroscopy.
3. Turbine Building Stack and Feedpump Room Vent - Filters are changed weekly and analyzed using gamma spectroscopy.
d. Liquid effluents:

Analysis per batch release using gamma spectrometry with a germanium detector, a low background beta counter, and a liquid scintillation counter.

5. Batch Releases
a. Liquid
1. Number of batch releases: None
2. Total time period for batch releases: N/A
3. Maximum time period for a batch release: N/A
4. Average time period for batch releases: N/A
5. Minimum time period for a batch release: N/A
6. Average stream flow during periods of release of effluent into a flowing stream: N/A
b. Gaseous
1. Number of batch releases: None
2. Total time period for batch release: N/A
3. Maximum time period for a batch release: N/A
4. Average time period for batch releases: N/A
5. Minimum time period for a batch release: N/A
6. Abnormal releases
a. Liquid
1. Number of releases: None
2. Total activity released: N/A
b. Gaseous
1. Number of releases: None
2. Total activity released: N/A 6

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE IA GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Unit I Quarter Quarter Quarter Quarter Yearly I Est. Total I

1 I

2 3

4 Total I Error, %

A. Fission & activation gases

1. Total release Ci 6.90E+01 1.85E+02 1.30E+01 1.27E+02 3.94E+02

+ 25

2. Average release rate for period (elevated release only) u Ci/sec 8.66E+00 2.35E+01 1.64E+00 1.59E+02 1.24E+01
3. Percent of Technical Specification
a. 0.2 1/Energy (average) - gamma (elevated release only) 2.09E-03 9.20E-03 1.94E-04 3.27E-02 3.68E-03
b. Dose rate due to gaseous effluent Total Body - 500 mrem/year Skin - 3000 mrem/year
c. Air dose due to noble gas in gaseous effluent 5 mRad/calendar quarter due to gamma radiation 2.72E-01 1.17E-01 4.682-03 6.14E-02 10 mRad/calendar quarter due to beta radiation 1.77E-01 1.07E-02 6.19E-04 5.83E-03 10 mRad/calendar year due to gamma radiation 1.91 E-01 20 mRad/calendar year due to beta radiation 9.05E-02 B. lodines
1. Total iodine-131 Ci 9.16E-03 1.33E-02 7.23E-03 8.49E-03 3.8220

+25

2. Average release rate for period (elevated release only) u Ci/sec 1.18E-03 1.69E-03 9.10E-04 1.07E-03 1.21E-03
3. Percent of Technical Specification
a. Dose rate due to gaseous effluent Any body organ - 1500 mrem/year (H-3, 1-131,1-133, & Part. TI/2 > 8 D)
b. Dose due to radioiodine and particulates in gaseous effluent Any body organ per calendar quarter-7.5 mrem 1.40E-01 8.77E-01 5.13E-01 2.27E+00 Any body organ per calendar year - 15 mrem 1.44E+00 C. Particulates
1. Particulates with half-lives > 8 days Ci 7.37E-03 2.30E-03 3.01E-03 4.30E-02 5-57.-02

+1-25

2. Average release rate for period (elevated release only) u Ci/sec 9.47E-04 2.93E-04 3.79E-04 5.41E-03 1.77E-03
3. Percent of Technical Specification
a. Dose rate due to gaseous effluent Any body organ - 1500 mrem/year (H-3,1-131,1-133, & Part. TI/2 > 8 D)
b. Dose due to radioiodine and particulates in gaseous effluent Any body organ per calendar quarter -7.5 mrem 1.40E-01 8.77E-01 5.13E-01 2.27E,00 Any body organ per calendar year - 15 mrem 14 0
4. Gross alpha radioactivity Ci 1.89E-06

.71.

E-0 6 1.31 E-06 6.00E-06 J

C. Tritium

1. Total Release Ci 9.83E+00 6.3912+00 7.732+00 4.002+00 [2.79E+01

+/-25

2. Average release rate for period (elevated release only) u Ci/sec 1.26E+00 8.02E-01 9.73E-01 5.04-01 I8.84E-01
3. Percent of Technical Specification
a. Dose rate due to gaseous effluent Any body organ - 1500 mrem/year (H-3.1-131,1-133. & Part. T112 >8 D)

F 4E-I-7

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 1B GASEOUS EFFLUENTS - ELEVATED RELEASES Continuous Mode Nuclides Released Unit Quarter Quarter Quarter Quarter Yearly 1

2 3

4 Total

1. Fission gases krypton-85 Ci

< LLD

< LLD

< LLD

< LLD

< LLD krypton-85m Ci 6.13E+00

< LLD

< LLD 5.82E+00 1.20E+01 krypton-87 Ci 2.55E+01 4.13E+01

< LLD 4.36E+01 1.10E+02 krypton-88 Ci 2.40E+00 4.90E+01

< LLD

< LLD 5.14E+01 xenon-133 Ci

< LLD

< LLD

< LLD 3.65E-03 3.65E-03 xenon-135 Ci 3.33E+01 9.47E+01 1.30E+01 7.73E+01 2.18E+02 xenon-135m Ci

< LLD

< LLD

< LLD 4.43E-02 4.43E-02 xenon-138 Ci

< LLD

< LLD

< LLD

< LLD

< LLD Others None Total for period Ci 6.73E+01 1.85E+02 1.30E+01 1.27E+02 3.92E+02

2. lodines iodine-131 Ci 9.16E-03 1.33E-02 7.23E-03 8.49E-03 3.82E-02 iodine-133 Ci 3.60E-02 6.92E-02 4.97E-02 4.07E-02 1.96E-01 iodine-135 Ci 3.74E-02 9.64E-02 7.28E-02 4.47E-02 2.51 E-01 Others iodine-129 Ci

< LLD

< LLD 3.14E-06 1.50E-06 4.64E-06 iodine-132 Ci 1.31E-02 4.53E-02 3.89E-02 2.20E-02 1.19E-01 iodine-134 Ci 1.89E-02 3.14E-02 4.39E-02 8.06E-03 1.02E-01 Total for period Ci 1.15E-01 2.56E-01 2.13E-01 1.24E-01 7.07E-01 C. Particulates strontium-89 Ci 3.60E-03 8.32E-04 1.21E-03 3.28E-02 3.84E-02 strontium-90 Ci 3.00E-05 1.43E-05 3.72E-04 5.22E-05 4.69E-04 cesium-134 Ci

< LLD

< LLD

< LLD

< LLD

< LLD cesium-137 Ci

< LLD 1.72E-05 1.45E-05 1.12E-04 1.44E-04 barium-140 Ci 3.72E-03 1.43E-03 1.37E-03 1.00E-02 1.65E-02 lanthanum-140 Ci

< LLD

< LLD

< LLD

< LLD

< LLD Others manganese-54 Ci

< LLD 1.03E-05

< LLD 1.48E-05 2.51E-05 cobalt-60 Ci

< LLD

< LLD 4.16E-05

< LLD 4.16E-05 Total for period Ci 7.35E-03 2.30E-03 3.01-03 4.30E-02 5.56E-02 8

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE IC GASEOUS EFFLUENTS - GROUND-LEVEL RELEASES Continuous Mode Nuclides Released Unit Quarter Quarter Quarter Quarter Yearly 1

2 3

4 Total

1. Fission gases krypton-85 Ci

< LLD

< LLD

< LLD

< LLD

< LLD krypton-85m Ci 8.78E-02

< LLD

< LLD

< LLD 8.78E-02 krypton-87 Ci 3.77E-01

< LLD

< LLD

< LLD 3.77E-01 krypton-88 Ci 1.09E-01

< LLD

< LLD

< LLD 1.09E-01 xenon-133 Ci

< LLD

< LLD 4.68E-04

< LLD 4.68E-04 xenon-135 Ci 1.11E+00

< LLD

< LLD

< LLD 1.11E+00 xenon-135m Ci

< LLD

< LLD

< LLD

< LLD

< LLD xenon-138 Ci

< LLD

< LLD

< LLD

< LLD

< LLD Others None Total for period Ci 1.68E+00

< LLD 4.68E-04

<LLD 1.68E+00

2. Iodines iodine-131 Ci 8.51 E-08 4.39E-07 2.03E-07 4.52E-06 5.25E-06 iodine-133 Ci

< LLD 8.24E-07 8.94E-06 2.99E-06 1.28E-05 iodine-135 Ci

< LLD

< LLD

< LLD

< LLD

< LLD Others None Total for period Ci 8.51 E-08 1.26E-06 9.14E-06 7.51 E-06 1.80E-05 C. Particulates strontium-89 Ci 1.67E-05

< LLD 2.82E-06 6.77E-06 2.63E-05 strontium-90 Ci 1.40E-08 2.50E-07

< LLD

< LLD 2.64E-07 cesium-134 Ci

< LLD

< LLD

< LLD

< LLD

< LLD cesium-137 Ci

< LLD

< LLD

< LLD

< LLD

< LLD barium-140 Ci

< LLD

< LLD

< LLD

< LLD

< LLD lanthanum-140 Ci

< LLD

< LLD

< LLD

< LLD

< LLD Others None Total for period Ci 1.67E-05 2.50E-07 2.82E-06 6.77E-06 2.66E-05 I

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 2A LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES Unit Quarter Quarter Quarter Quarter Yearly Est. Total 1

2 3

4 Total Error, %

A. Fission & activation products

1. Total release (not including tritium, gases, alpha)

Ci No releases No releases No releases No releases No releases N/A

2. Average diluted concentration during period u Ci/ml N/A N/A N/A N/A N/A
3. Percent of Technical Specification
a. Radioactivity Concentration in Liquid Effluent The concentration of radioactive material, other than noble gases shall not exceed 10 times the liquid effluent concentrations specified in 10CFR Part 20.1001-20.2401, Appendix B, Table II, Column 2
b. Limit on Dose Due to Liquid Effluent Total Body - 1.5 mren/calendar quarter N/A N/A N/A N/A Any Body Organ - 5.0 mrem/calendar quarter N/A N/A N/A N/A Total Body - 3.0 mrem/calendar year N/A Any Body Organ - 10.0 mrem/calendar year

%N/A B. Tritium

1. Total release Ci No releases No releases No releases No releases No releases N/A
2. Average diluted concentration during period u Ci/ml N/A N/A N/A N/A N/A
3. Percent of Technical Specification
a. Shall not exceed 10 times the liquid effluent concentrations specified in IOCFR Part 20.1001-20.2401, Appendix B, Table II, Column 2
b. Limit on Dose Due to Liquid Effluent Total Body - 1.5 mrem/calendar quarter N/A N/A N/A N/A Any Body Organ - 5.0 mrem/calendar quarter N/A N/A N/A N/A Total Body - 3.0 mrem/calendar year N/A Any Body Organ - 10.0 mrem/calendar year N/A C. Dissolved and entrained gases
1. Total release Ci No releases No releases No releases No releases Noreaes No rla
2. Average diluted concentration during period u Ci/ml N/A N/A N/A N/A N/A
3. Percent of Technical Specification
a. Shall not exceed 2.0 E-4 u Ci/ml
b. Limit on Dose Due to Liquid Effluent Total Body - 1.5 mrem/calendar quarter N/A N/A N/A

]

N/A Any Body Organ - 5.0 mrem/calendar quarter N/A N/A N/A N/A Total Body - 3.0 mrem/calendar year N/A Any Body Organ - 10.0 mrem/calendar year N/A D. Gross alpha radioactivity

1. Total release Ci No releases No releases No releases No releases No releases No releases E. Volume of waste released (prior to dilution) liters No releases No releases No releases No releases No releasýes N releases F. Volume of dilution water used during period liters 4.731+11 4.31E+11 4.91E+11 4.67E+11 1.86E+12

+/- 10

[10

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 2B LIQUID EFFLUENTS Batch Mode Nuclides Released Unit Quarter Quarter Quarter Quarter Yearly 1

2 1

3 1

4 Total strontium-89 Ci No releases No releases No releases No releases No releases strontium-90 Ci No releases No releases No releases No releases No releases cesium-134 Ci No releases No releases No releases No releases No releases cesium-137 Ci No releases No releases No releases No releases No releases iodine-131 Ci No releases No releases No releases No releases No releases cobalt-58 Ci No releases No releases No releases No releases No releases cobalt-60 Ci No releases No releases No releases No releases No releases iron-59 Ci No releases No releases No releases No releases No releases zinc-65 Ci No releases No releases No releases No releases No releases manganese-54 Ci No releases No releases No releases No releases No releases chromium-51 Ci No releases No releases No releases No releases No releases zirconium-95 Ci No releases No releases No releases No releases No releases niobium-95 Ci No releases No releases No releases No releases No releases technetium-99m Ci No releases No releases No releases No releases No releases barium-140 Ci No releases No releases No releases No releases No releases lanthanum-140 Ci NO releases No releases No releases No releases No releases cerium-141 Ci No releases No releases No releases No releases No releases Other Ci No releases No releases No releases No releases No releases unidentified Ci No releases No releases No releases No releases No releases Total for period Ci No releases No releases No releases No releases INo releases xenon-133 Ci No releases No releases No releases No releases No releases xenon-[35 Ci No releases No releases No releases No releases No releases Total for period Ci No releases No releases No releases No releases No releases

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3A SOLID WASTE AND IRRADIATED FUEL SHIPMENTS -

SUMMARY

]A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)[

1. Type of waste Unit Yearly Est.

Total Total Error, %

a. Spent resins, filters, filter sludges, etc m3 5.59E+01

+/-25 Ci 5.23E+01

b. Dry compressible waste, contaminated equipment, etc.

m3 1.87E+03

,+/- 25 Ci 4.08E+00

c. Irradiated components, control rods, etc.

m3 1.63E+00

,+/- 25 Ci 2.09E+03

d. Evaporator Bottoms (shipped in liquid form to a Waste m3 1.52E+01,

25 Processor)

Ci 1.58E-04 Note: No solidification agent was used during the reporting period

2. Estimate of major nuclear composition (by type of waste)
a. cobalt-60 cesium-137 H-3
b. cobalt-60 iron-55 cesium-137
c. cobalt-60 iron-55 nickel-63
d. cesium-137 cesium-134 cobalt-60 Note - See attached tables (Table 3B) for additional data
3. Solid Waste Disposition Number of Shipments Mode of Transportation Destination 39 Motor Vehicle Oak Ridge, T.N.

12 Motor Vehicle Barnwell, S.C.

B. IRRADIATED FUEL SHIPMENTS (Disposition)

Number of Shipments Mode of Transportation Destination None Shipped 4.14E+01 2.17E+01 2.74E+01 1.43E+01 8.81 E+00 4.61 E+00 4.58E+01 1.87E+00 2.34E+01 9.56E-01 2.21 E+01 9.03E-01 4.75E+01 9.90E+02 4.12E+01 8.59E+02 9.35E+00 1.95E+02 5.27E+01 8.33E-05 2.33E+01 3.68E-05 1.01 E+01 1.60E-05 Percentage (%)

Activity (Ci)

I

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Waste Stream - Summary Of All Wastes Period of Performance: January 1, 2001 through December 31, 2001 IWaste Class A

B C

All Volume Shi ed (Ft3)

I (3

6.83E+04 1.93E+03 3.59E+02 I 1.02E+01 5.74E+01 1.63E+00 6.87E+04 I 1.95E+03 Activity Shipped (Curies) 1.13E+01 4.5 1E+01 2.09E+03 2.14E+03 Percent Error (Percent)

F3I

Estimate of Major Nuclide Composition - Summary of All Shipments Period of Performance: January 1, 2001 through December 31, 2001 I

Waste Class: B Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 1.93E+01 4.28E+01 Cs-137 1.36E+01 3.02E+01 H-3 3.92E+00 8.69E+00 Fe-55 2.91 E+00 6.45E+00 C-14 1.89E+oo 4.19E+00 Mn-54 1.40E+00 3.1 OE+00 Sr-90 2.27E-01 5.03E-01 Pu-241 1.68E-01 3.73E-01 Ni-63 1.09E-01 2.42E-01 Ni-59 3.40E-03 7.54E-03 Cm-242 2.35E-03 5.21 E-03 Other 1.60E+o0 3.55E+00 Total 4.51 E+01 1.OOE+02 F

I Waste Class: C Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 9.90E+02 4.75E+01 Fe-55 8.59E+02 4.12E+01 Ni-63 1.95E+02 9.35E+00 Sb-125 4.02E+01 1.93E+00 Ni-59 9.49E-01 4.55E-02 C-14 4.04E-01 1.94E-02 H-3 6.23E-02 2.99E-03 Nb-94 4.84E-02 2.32E-03 Pu-241 4.62E-03 2.22E-04 Tc-99 1.43E-03 6.86E-05 Cm-242 5.95E-08 2.85E-09 Other 0.OOE+00 0.00E+00 Total 2.09E+03 1.00E+02 OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (cont.)

SOI.TD WASTE AND IRRADIATED FUEL SHIPMENTS Waste Class: A Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 4.24E+00 3.76E+01 C-14 1.78E+00 1.58E+01 Cs-137 1.63E+00 1.44E+01 Fe-55 1.56E+00 1.38E+01 H-3 6.92E-01 6.13E+00 Mn-54 5.93E-01 5.25E+00 Fe-59 1.56E-01 1.38E+00 Ni-63 4.20E-02 3.72E-01 Sr-90 3.40E-02 3.01E-01 Pu-241 1.82E-02 1.61E-01 Ni-59 2.OOE-04 1.77E-03 Cm-242 1.OOE-05 8.86E-05 Other 6.00E-01 5.31E+00 Total 1.13E+01 1.00E+02 Waste Class: All Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 1.01E+03 4.74E+01 Fe-55 8.63E+02 4.03E+01 Ni-63 1.95E+02 9.12E+00 Sb-125 4.02E+01 1.88E+00 Cs-137 1.52E+01 7.12E-01 H-3 4.67E+00 2.18E-01 C-14 4.07E+00 1.90E-01 Ni-59 9.53E-01 4.45E-02 Sr-90 2.61E-01 1.22E-02 Pu-241 1.91E-01 8.92E-03 Nb-94 4.84E-02 2.26E-03 Cm-242 2.36E-03 1.1OE-04 Tc-99 1.43E-03 6.68E-05 Other 2.20E+00 1.03E-01 Total 2.14E+03 1.00E+02

Waste Stream - Spent Resins, Filters, and Filter Sludge Period of Performance: January 1, 2001 through December 31,2001 Volume Shipped (Ft3)

(M3 1.61E+03 I 4.57E+01

-I'--

3.59E+02 1.02E+01 None I

None 1.97E+03 5.59E+01 Activity Shipped (Curies) 7.21E+00 4.51E+01 None 5.23E+01 Percent Error (Percent)

+/- 25 %

+/- 25 %

N/A

+/-25 %

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (cont.)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Waste Class A

B C

All

OYSTER CREEK GENERATING STATION I Estimate of Major Nuclide Composition - Spent Resins, Filters, and Filter Sludge Period of Performance: January 1, ;001 through December 31, 2001 Waste Class: A Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 2.37E+00 3.29E+01 C-14 1.78E+00 2.47E+01 Cs-137 7.30E-01 1.01E+01 H-3 6.86E-01 9.52E+00 Fe-55 6.06E-01 8.41E+00 Mn-54 4.11E-01 5.70E+00 Fe-59 1.56E-01 2.16E+00 Co-58 9.81E-02 1.36E+00 Cs-134 9.24E-02 1.28E+00 Zn-65 7.63E-02 1.06E+00 Sr-90 3.1OE-02 4.30E-01 Ni-63 2.30E-02 3.19E-01 Pu-241 1.72E-02 2.39E-01 Cm-242 2.56E-04 3.55E-03 Other 1.30E-01 1.80E+00 Total 7.21E+00 1.00E+02 Waste Class: All Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 2.17E+01 4.14E+01 Cs-137 1.43E+01 2.74E+01 H-3 4.61E+00 8.81E+00 C-14 3.67E+00 7.02E+00 Fe-55 3.52E+00 6.72E+00 Mn-54 1.8 1E+00 3.46E+00 Sr-90 2.58E-01 4.93E-01 Pu-241 1.85E-01 3.54E-01 Fe-59 1.56E-01 2.98E-01 Ni-63 1.32E-01 2.52E-01 Co-58 9.81E-02 1.88E-01 Cs-134 9.24E-02 1.77E-01 Zn-65 7.63E-02 1.46E-01 Ni-59 3.40E-03 6.50E-03 Cm-242 2.61E-03 4.98E-03 Other 1.70E+00 3.25E+00 Total 5.23E+01 1.OOE+02

[

Waste Class: B Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 1.93E+01 4.28E+01 Cs-137 1.36E+01 3.02E+01 H-3 3.92E+00 8.69E+00 Fe-55 2.91 E+00 6.45E+00 C-14 1.89E+00 4.19E+00 Mn-54 1.40E+00 3.1OE+00 Sr-90 2.27E-01 5.03E-01 Pu-241 1.68E-01 3.73E-01 Ni-63 1.09E-01 2.42E-01 Ni-59 3.40E-03 7.54E-03 Cm-242 2.35E-03 5.21 E-03 Other 1.57E+00 3.48E+00 Total 4.51 E+01 1.OOE+02 I.

E Waste Class: C Nuclide Activity Percent Abundance (Curies)

(Percent)

N 0

N E

S H

I P

P E

D Total N/A N/A ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (cont.)

I SOLID WASTE AND IRRADIATED FUEL SHIPMENTS OYSTER CREEK GENERATING STATION I

Waste Stream - Dry Activated Waste Shipped To An Offsite Waste Processor Period of Performance: January 1, 2001 through December 31, 2001 Volume Shipped (Ft')

I (3

6.61E+04,1 1.87E+03 None None None None 6.61E+04 1 1.87E+03 Activity Shipped (Curies) 4.08E+00 None None 4.08E+00 Percent Error (Percent)

+/- 25 %

N/A N/A

+/- 25 %

L17 OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (CONT.)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Waste Class A

B C

All

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (cont.)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Estimate of Major Nuclide Composition - Dry Activated Waste Shipped to an Offsite Waste Processor Period of Performance: January 1, 2001 through December 31, 2001 Waste Class: A Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 1.87E+00 4.58E+01 Fe-55 9.56E-01 2.34E+01 Cs-137 9.03E-01 2.21E+01 Mn-54 1.82E-01 4.46E+00 Cr-51 5.70E-02 1.40E+00 Ni-63 1.90E-02 4.66E-01 H-3 6.OOE-03 1.47E-01 C-14 3.OOE-03 7.35E-02 Sr-90 3.OOE-03 7.35E-02 Pu-241 1.00E-03 2.45E-02 Ni-59 2.40E-04 5.88E-03 Cm-242 1.OOE-05 2.45E-04 Other 8.OOE-02 1.96E+00 Total 4.08E+00 1.OOE+02 Waste Class: All I

Nuclide Activity Percent]

Abundance (Curies)

(Percent)

Co-60 1.87E+00 4.58E+01 Fe-55 9.56E-01 2.34E+01 Cs-137 9.03E-01 2.21E+01 Mn-54 1.82E-01 4.46E+00 Cr-51 5.70E-02 1.40E+00 Ni-63 1.90E-02 4.66E-01 H-3 6.00E-03 1.47E-01 C-14 3.OOE-03 7.35E-02 Sr-90 3.OOE-03 7.35E-02 Pu-241 1.00E-03 2.45E-02 Ni-59 2.40E-04 5.88E-03 Cm-242 1.00E-05 2.45E-04 Other 8.OOE-02 1.96E+00 Total 4.08E+00 1.00E+02 E

Waste Class: B Nuclide Activity Percent Abundance (Curies)

(Percent)

IWaste Class: C Nuclide Activity Percent Abundance (Curies)

(Percent)

N 0

N E

S H

I P

P E

D Total N/A N/A

Waste Stream - Irradiated Components Period of Performance: January 1, 2001 through December 31, 2001 Volume Shipped (FtN)

Non None None None 1

None 5.74E+01 1.63E+00 5.74E+01 1.63E+00 Activity Shipped (Curies)

None None 2.09E+03 2.09E+03 Percent Error (Percent)

N/A N/A

+/- 25%

+/- 25%

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (CONT.)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Waste Class A

B C

All

Estimate of Major Nuclide Composition - Irradiated Components Period of Performance: January 1, 2001 through December 31, 2001 Waste Class: B Nuclide Activity Percent Abundance (Curies)

(Percent)

N 0

N E

S H

I P

P E

D Total N/A N/A Waste Class: C

[

Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 9.90E+02 4.75E+01 Fe-55 8.59E+02 4.12E+01 Ni-63 1.95E+02 9.35E+00 Sb-125 4.02E+01 1.93E+00 Ni-59 9.49E-01 4.55E-02 C-14 4.04E-01 1.94E-02 H-3 6.23E-02 2.99E-03 Nb-94 4.84E-02 2.32E-03 Pu-241 4.62E-03 2.22E-04 Tc-99 1.43E-03 6.86E-05 Cm-242 5.95E-08 2.85E-09 Other 0.OOE+00 0.OOE+00 Total 2.09E+03 1.00E+02 OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (cont.)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Waste Class: A Nuclide Activity Percent Abundance (Curies)

(Percent)

N 0

N E

S H

I P

P E

D Total N/A N/A Waste Class: All Nuclide Activity Percent Abundance (Curies)

(Percent)

Co-60 9.90E+02 4.75E+01 Fe-55 8.59E+02 4.12E+01 Ni-63 1.95E+02 9.35E+00 Sb-125 4.02E+01 1.93E+00 Ni-59 9.49E-01 4.55E-02 C-14 4.04E-01 1.94E-02 H-3 6.23E-02 2.99E-03 Nb-94 4.84E-02 2.32E-03 Pu-241 4.62E-03 2.22E-04 Tc-99 1.43E-03 6.86E-05 Cm-242 5.95E-08 2.85E-09 Other 0.OOE+00 0.OOE+00 Total 2.09E+03 1.00E+02

I Waste Stream - Contaminated Water Shipped To An Offsite Waste Processor Period of Performance: January 1, 2001 through December 31, 2001 Waste Class Volume Shi ped Activity Shipped Percent Error (Ft)~

3L (Curies)

(Percent)

A 5.35E+02 1.52E+01 1.58E-04

+/- 25 %

B No None None-N/A B

None None None N/A C

None None None N/A All 5.35E+02 1.52E+01 1.58E-04

+/-25 %

Note: All waste was processed at an off-site processor and no waste was buried OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (CONT.)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS

-Estimate of Major Nuclide Composition - Contaminated Water Sent To A Waste Processor Period of Performance: January 1, 2001 through December 31, 2001 1

IWaste Class: B Nuclide Activity Percent Abundance (Curies)

(Percent)

N 0

N E

S H

I P

P E

D Total N/A N/A I

I Waste Class: C Nuclide Activity Percent Abundance (Curies)

(Percent)

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 3B (cont.)

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Waste Class: A Nuclide Activity Percent Abundance (Curies)

(Percent)

Cs-137 8.33E-05 5.27E+01 Cs-134 3.68E-05 2.33E+01 Co-60 1.60E-05 1.01E+01 Fe-55 8.87E-06 5.61E+00 Mn-54 7.01E-06 4.44E+00 Co-58 3.18E-06 2.0E1+00 H-3 5.22E-07 3.30E-01 Sr-90 2.52E-07 1.59E-01 Ni-63 1.73E-07 1.09E-01 Pu-241 1.15E-07 7.28E-02 C-14 3.24E-08 2.05E-02 Ni-59 2.13E-09 1.35E-03 Cm-242 7.59E-10 4.80E-04 Other 2.OOE-06 1.27E+00 Total 1.58E-04 1.00E+02 Waste Class: All Nuclide Activity Percent Abundance (Curies)

(Percent)

Cs-137 8.33E-05 5.27E+01 Cs-134 3.68E-05 2.33E+01 Co-60 1.60E-05 1.01E+01 Fe-55 8.87E-06 5.61E+00 Mn-54 7.01E-06 4.44E+00 Co-58 3.18E-06 2.01E+00 H-3 5.22E-07 3.30E-01 Sr-90 2.52E-07 1.59E-01 Ni-63 1.73E-07 1.09E-01 Pu-241 1.15E-07 7.28E-02 C-14 3.24E-08 2.05E-02 Ni-59 2.13E-09 1.35E-03 Cm-242 7.59E-10 4.80E-04 Other 2.00E-06 1.27E+00 Total 1.58E-04 1.00E+02 I

I

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

All Pasquill Categories ELEVATION:

33 foot Wind Wind Speed (mph) at 33 foot level Direction 1 -3 4-7 8-12 13-18 19-24

> 24 Total N

84 109 63 3

0 0

259 NNE 52 100 35 1

0 0

188 NE 54 125 106 13 0

0 298 ENE 55 146 140 21 4

0 366 E

41 168 130 8

0 0

347 ESE 30 116 64 1

0 0

211 SE 48 156 103 2

0 0

309 SSE 56 124 127 19 0

0 326 S

55 159 187 47 0

0 448 SSW 96 264 212 61 4

0 637 SW 153 328 134 9

0 0

624 WSW 303 545 150 7

0 0

1005 W

377 461 169 21 1

0 1029 WNW 231 295 261 61 6

0 854 NW 197 380 278 75 0

0 930 NNW 128 251 170 27 0

0 576 VARIABLE 0

0 0

0 0

0 0

TOTAL 1960 3727 2329 376 15 0

8407 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

353 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A HOURS AT EACH WIND SPEED AND DIRECTION

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category A ELEVATION:

33 foot Wind Wind Speed (mph) at 33 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

0 12 23 2

0 0

37 NNE 1

8 4

0 0

0 13 NE 0

14 40 0

0 0

54 ENE 1

31 65 6

0 0

103 E

0 29 43 1

0 0

73 ESE 1

47 32 0

0 0

80 SE 2

31 71 2

0 0

106 SSE 0

7 62 8

0 0

77 S

0 6

57 30 0

0 93 SSW 0

14 30 13 0

0 57 SW 1

17 41 6

0 0

65 WSW 0

26 80 3

0 0

109 W

3 23 59 9

0 0

94 WNW 0

22 81 24 5

0 132 NW 0

18 101 32 0

0 151 NNW 0

14 51 8

0 0

73 VARIABLE 0

0 0

0 0

0 0

TOTAL 9

319 840 144 5

0 1317 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

353 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category B ELEVATION:

33 foot Wind Wind Speed (mph) at 33 foot level Direction 1-3 4-7 8 -12 13 -18 19 - 24

> 24 Total N

1 17 8

0 0

0 26 NNE 0

12 2

0 0

0 14 NE 1

7 8

0 0

0 16 ENE 1

11 9

0 0

0 21 E

0 18 12 1

0 0

31 ESE 1

6 5

0 0

0 12 SE 0

12 8

0 0

0 20 SSE 0

9 17 1

0 0

27 S

1 2

19 1

0 0

23 SSW 2

9 11 5

0 0

27 SW 1

6 10 1

0 0

18 WSW 0

14 16 3

0 0

33 W

1 16 15 4

0 0

36 WNW 0

15 31 7

1 0

54 NW 1

16 22 7

0 0

46 NNW 0

13 12 9

0 0

34 VARIABLE 0

0 0

0 0

0 0

TOTAL 10 183 205 39 1

0 438 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

353 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category C ELEVATION:

33 foot Wind Wind Speed (mph) at 33 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

1 6

1 0

0 0

8 NNE 0

9 2

0 0

0 11 NE 1

6 5

0 0

0 12 ENE 3

6 2

0 0

0 11 E

1 5

7 0

0 0

13 ESE 0

7 4

0 0

0 11 SE 0

6 4

0 0

0 10 SSE 0

5 9

0 0

0 14 S

0 2

16 0

0 0

18 SSW 1

4 6

2 0

0 13 SW 0

5 4

0 0

0 9

WSW 0

11 3

0 0

0 14 W

0 8

7 1

0 0

16 WNW 1

10 10 3

0 0

24 NW 0

9 13 5

0 0

27 NNW 1

10 5

2 0

0 18 VARIABLE 0

0 0

0 0

0 0

TOTAL 9

109 98 13 0

0 229 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

353 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category D ELEVATION:

33 foot Wind Wind Speed (mph) at 33 foot level Direction 1 -3 4-7 8-12 13-18 19-24

> 24 Total N

14 35 21 0

0 0

70 NNE 15 45 6

1 0

0 67 NE 18 54 39 0

0 0

111 ENE 12 54 40 4

0 0

110 E

12 62 49 3

0 0

126 ESE 8

26 15 0

0 0

49 SE 10 56 16 0

0 0

82 SSE 7

54 18 4

0 0

83 S

8 62 64 7

0 0

141 SSW 5

39 69 10 0

0 123 SW 10 45 24 1

0 0

80 WSW 13 60 23 0

0 0

96 W

9 40 31 4

0 0

84 WNW 7

39 54 12 0

0 112 NW 16 69 68 16 0

0 169 NNW 14 68 41 8

0 0

131 VARIABLE 0

0 0

0 0

0 0

TOTAL 178 808 578 70 0

0 1634 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

353 Hours a

The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category E ELEVATION:

33 foot Wind Wind Speed (mph) at 33 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

34 24 10 1

0 0

69 NNE 18 25 21 0

0 0

64 NE 25 40 13 13 0

0 91 ENE 22 43 22 11 4

0 102 E

20 48 19 3

0 0

90 ESE 17 28 8

1 0

0 54 SE 28 50 4

0 0

0 82 SSE 31 43 21 6

0 0

101 S

21 76 31 9

0 0

137 SSW 37 160 94 31 4

0 326 SW 43 146 54 1

0 0

244 WSW 59 146 24 1

0 0

230 W

49 153 55 3

1 0

261 WNW 37 94 82 15 0

0 228 NW 34 133 74 15 0

0 256 NNW 39 68 61 0

0 0

168 VARIABLE 0

0 0

0 0

0 0

TOTAL 514 1277 593 110 9

0 2503 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

353 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category F ELEVATION:

33 foot Wind Wind Speed (mph) at 33 foot level Direction 1-3 4-7 8 -12 13 -18 19 - 24

> 24 Total N

7 6

0 0

0 0

13 NNE 12 0

0 0

0 0

12 NE 5

3 1

0 0

0 9

ENE 6

0 2

0 0

0 8

E 4

5 0

0 0

0 9

ESE 1

2 0

0 0

0 3

SE 4

1 0

0 0

0 5

SSE 10 6

0 0

0 0

16 S

13 9

0 0

0 0

22 SSW 23 26 2

0 0

0 51 SW 36 79 1

0 0

0 116 WSW 43 121 3

0 0

0 167 W

50 94 2

0 0

0 146 WNW 44 78 3

0 0

0 125 NW 32 68 0

0 0

0 100 NNW 23 33 0

0 0

0 56 VARIABLE 0

0 0

0 0

0 0

TOTAL 313 531 14 0

0 0

858 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

353 Hours a

The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category G ELEVATION:

33 foot Wind Wind Speed (mph) at 33 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

27 9

0 0

0 0

36 NNE 6

1 0

0 0

0 7

NE 4

1 0

0 0

0 5

ENE 10 1

0 0

0 0

11 E

4 1

0 0

0 0

5 ESE 2

0 0

0 0

0 2

SE 4

0 0

0 0

0 4

SSE 8

0 0

0 0

0 8

S 12 2

0 0

0 0

14 SSW 28 12 0

0 0

0 40 SW 62 30 0

0 0

0 92 WSW 188 167 1

0 0

0 356 W

265 127 0

0 0

0 392 WNW 142 37 0

0 0

0 179 NW 114 67 0

0 0

0 181 NNW 51 45 0

0 0

0 96 VARIABLE 0

0 0

0 0

0 0

TOTAL 927 500 1

0 0

0 1428 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

353 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation E

0 OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

Ha HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

All Pasquill Categories ELEVATION:

380 foot Wind Wind Speed (mph) at 380 foot level Direction 1 -3 4-7 8-12 13-18 19-24

> 24 Total N

13 66 156 128 68 2

433 NNE 12 59 100 70 26 1

268 NE 12 67 110 138 62 28 417 ENE 17 46 150 137 75 25 450 E

6 66 140 85 35 5

337 ESE 10 77 135 54 5

1 282 SE 17 53 141 65 10 3

289 SSE 4

59 130 111 23 13 340 S

6 43 152 202 40 11 454 SSW 5

37 161 311 163 53 730 SW 11 32 141 235 214 41 674 WSW 11 60 161 269 194 74 769 W

14 69 151 240 210 74 758 WNW 9

42 135 309 240 109 844 NW 8

47 162 299 295 147 958 NNW 10 43 93 206 196 47 595 VARIABLE 0

0 0

0 0

0 0

TOTAL 165 866 2218 2859 1856 634 8598 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

162 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A HOURS AT EACH WIND SPEED AND DIRECTION

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category A ELEVATION:

380 foot Wind Wind Speed (mph) at 380 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

1 0

4 11 1

0 17 NNE 0

0 1

0 0

0 1

NE 0

1 2

10 3

0 16 ENE 0

0 10 12 6

0 28 E

0 1

7 4

0 0

12 ESE 0

0 10 1

0 0

11 SE 0

0 7

8 0

0 15 SSE 0

0 4

13 0

0 17 S

0 1

2 17 4

1 25 SSW 0

2 3

2 2

0 9

SW 0

0 6

8 1

0 15 WSW 0

1 4

18 4

0 27 W

0 1

6 3

7 2

19 WNW 1

0 2

16 7

2 28 NW 0

0 3

5 12 2

22 NNW 0

0 0

13 5

1 19 VARIABLE 0

0 0

0 0

0 0

TOTAL 2

7 71 141 52 8

281 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

162 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category B ELEVATION:

380 foot Wind Wind Speed (mph) at 380 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

0 2

6 3

2 0

13 NNE 0

1 1

1 0

0 3

NE 0

1 7

20 6

0 34 ENE 0

1 28 11 1

0 41 E

0 0

21 0

0 0

21 ESE 1

4 13 1

0 0

19 SE 0

4 23 8

0 0

35 SSE 0

0 8

17 0

0 25 S

0 0

6 27 7

1 41 SSW 0

1 10 7

3 1

22 SW 0

2 8

8 3

0 21 WSW 0

1 18 23 4

1 47 W

0 2

19 22 4

2 49 WNW 0

0 13 28 8

17 66 NW 0

2 9

22 12 10 55 NNW 0

0 4

13 4

5 26 VARIABLE 0

0 0

0 0

0 0

TOTAL 1

21 194 211 54 37 518 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

162 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation 33]

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category C ELEVATION:

380 foot Wind Wind Speed (mph) at 380 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

0 4

10 3

0 0

17 NNE 0

7 6

2 3

0 18 NE 0

5 7

11 6

0 29 ENE 0

0 20 14 1

0 35 E

0 5

17 7

0 0

29 ESE 0

11 22 3

0 0

36 SE 0

3 27 6

0 0

36 SSE 0

2 15 16 1

1 35 S

0 2

8 24 6

0 40 SSW 0

1 12 19 7

0 39 SW 0

2 11 16 5

1 35 WSW 1

5 18 24 6

1 55 W

1 3

23 21 5

1 54 WNW 0

5 20 30 14 13 82 NW 0

2 20 19 16 20 77 NNW 0

3 12 9

4 5

33 VARIABLE 0

0 0

0 0

0 0

TOTAL 2

60 248 224 74 42 650 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

162 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category D ELEVATION:

380 foot Wind Wind Speed (mph) at 380 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

6 35 41 20 22 1

125 NNE 3

26 42 34 18 1

124 NE 5

34 49 62 38 26 214 ENE 10 25 62 72 53 24 246 E

4 40 60 47 29 1

181 ESE 6

38 46 27 2

0 119 SE 7

21 60 34 2

1 125 SSE 1

32 68 36 10 7

154 S

1 16 81 80 15 5

198 SSW 1

16 60 132 61 29 299 SW 2

11 39 52 22 5

131 WSW 3

22 59 66 15 0

165 W

2 31 41 57 31 8

170 WNW 2

14 49 78 78 42 263 NW 1

19 65 116 79 62 342 NNW 4

24 37 68 53 15 201 VARIABLE 0

0 0

0 0

0 0

TOTAL 58 404 859 981 528 227 3057 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

162 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category E ELEVATION:

380 foot Wind Wind Speed (mph) at 380 foot level Direction 1-3 4-7 8-12 13-18 19-24

> 24 Total N

2 8

33 27 11 0

81 NNE 6

13 17 6

1 0

43 NE 3

12 16 15 6

2 54 ENE 4

7 18 24 14 1

68 E

2 7

22 15 6

4 56 ESE 3

8 31 18 3

1 64 SE 4

16 14 8

6 2

50 SSE 0

12 26 24 9

5 76 S

3 12 31 31 6

4 87 SSW 1

10 40 117 76 20 264 SW 2

8 34 75 103 13 235 WSW 2

14 20 56 63 17 172 W

6 20 26 57 81 25 215 WNW 4

8 22 69 61 16 180 NW 2

4 27 68 83 25 209 NNW 0

8 16 43 48 4

119 VARIABLE 0

0 0

0 0

0 0

TOTAL 44 167 393 653 577 139 1973 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

162 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category F ELEVATION:

380 foot Wind Wind Speed (mph) at 380 foot level Direction 1-3 4-7 8 -12 13 -18 19 - 24

> 24 Total N

2 3

21 37 14 1

78 NNE 2

2 9

13 1

0 27 NE 1

4 5

9 1

0 20 ENE 1

2 8

1 0

0 12 E

0 4

5 5

0 0

14 ESE 0

6 4

3 0

0 13 SE 1

4 2

0 0

0 7

SSE 0

4 6

0 1

0 11 S

1 5

14 19 1

0 40 SSW 0

3 11 26 13 3

56 SW 3

2 11 31 45 18 110 WSW 1

10 14 35 47 36 143 W

1 6

16 45 54 20 142 WNW 0

5 21 44 47 17 134 NW 1

6 11 35 64 21 138 NNW 3

4 9

33 55 15 119 VARIABLE 0

0 0

0 0

0 0

TOTAL 17 70 167 336 343 131 1064 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

162 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation E37 OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

PERIOD OF RECORD:

January 1, 2001 through December 31, 2001 STABILITY CLASS:

Pasquill Category G ELEVATION:

380 foot Wind Wind Speed (mph) at 380 foot level Direction 1-3 4-7 8 -12 13 -18 19 - 24

> 24 Total N

2 14 41 27 18 0

102 NNE 1

10 24 14 3

0 52 NE 3

10 24 11 2

0 50 ENE 2

11 4

3 0

0 20 E

0 9

8 7

0 0

24 ESE 0

10 9

1 0

0 20 SE 5

5 8

1 2

0 21 SSE 3

9 3

5 2

0 22 S

1 7

10 4

1 0

23 SSW 3

4 25 8

1 0

41 SW 4

7 32 45 35 4

127 WSW 4

7 28 47 55 19 160 W

4 6

20 35 28 16 109 WNW 2

10 8

44 25 2

91 NW 4

14 27 34 29 7

115 NNW 3

4 15 27 27 2

78 VARIABLE 0

0 0

0 0

0 0

TOTAL 41 137 286 313 228 50 1055 Periods of Calm (hours):

0 Hours Hours of missing data (Total):

162 Hours a The total number of hours of each category of wind direction for the indicated period of record, stability class and elevation OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4A (cont.)

HOURS AT EACH WIND SPEED AND DIRECTION

Stability Pasquill Sigma-Thetaa emperaturechange Classification Categories (degrees) with height (degrees-C/lO0m)

Extremely unstable A

25.0

< -1.9 Moderately unstable B

20.0

-1.9 to - 1.7 Slightly unstable C

15.0

-1.7 to - 1.5 Neutral D

10.0

-1.5 to -0.5 Slightly stable E

5.0

-0.5 to 1.5 Moderately stable F

2.5 1.5 to 4.0 Extremely stable G

1.7

> 4.0 a Standard deviation of horizontal wind direction fluctuation over a period of 15 minutes to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.

The values shown are averages for each stability classification.

E39 OYSTER CREEK GENERATING STATION ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - 2001 TABLE 4B CLASSIFICATION OF ATMOSPHERIC STABILITY