ML003711272

From kanterella
Jump to navigation Jump to search
Revised Epips,Including Revision 9 to 2000-EMG-3200.01A, RPV Control - No ATWS, Revision 9 to 2000-EMG-3200-01B, RPV Control - with ATWS, Revision 15 to 2000-EMG-3200.02, Primary Containment Control, Revision 8 to 2000-EMG-3200.10,
ML003711272
Person / Time
Site: Oyster Creek
(DPR-016)
Issue date: 04/27/2000
From:
GPU Nuclear Corp
To: Dromerick A
Office of Nuclear Security and Incident Response
References
-RFPFR
Download: ML003711272 (195)


Text

(4-Pu NUCLEAR DOCUMENT TRANSMITTAL April 27, 2000 To:

A.W. Dromerick-USNRC Sr. Project Manager Copy Serial #72 Mail Station P-137 Washington D.C. 20555 SEE LOTUS NOTES BULLETIN BOARD FOR LATEST REVISIONS PLEASE NOTE: IT IS IMPERATIVE THAT YOU NOTIFY 1RMC OF ADDRESS CHANGES!!

FILE CURRENT DESTROY OUTDATED PLEASE NOTE THESE PROCEDURES ARE NUMBERED ONLY AS EMG PROCEDURES:

2000-EMG-3200.01A ENTIRE REV.

9 2000-EMG-3200.01A ENTIRE REV.

8 2000-EMG-3200.01B ENTIRE REV.

9 2000-EMG-3200.01B ENTIRE REV.

8 2000-EMG-3200.02 ENTIRE REV.

15 2000-EMG-3200.02 ENTIRE REV.

14 2000-EMG-3200.10 ENTIRE REV.

8 2000-EMG-3200.10 ENTIRE REV.

7 2000-EMG-3200.11 ENTIRE REV.

10 2000-EMG-3200.11 ENTIRE REV.

9 REQUIRED ACTION:ADD REVISION TO YOUR CONTROLLED COPIES, DESTROY OUTDATED MATERIAL AND DISCARD TRANSMITTAL

r 0OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.01A NUCLEAR Title Revision No.

RPV CONTROL - NO ATWS 9

Applicability/Scope Responsible Office SYSTEMS ENG.

(EIC)

EMERGENCY OPERATING PROCEDURE FOR OYSTER CREEK E150 This document is within QA plan scope X Yes No Safety Reviews Required X Yes No Effective Date (04/25/00) 05/05/00 Prior Revision 8

incorporated the This Revision 9

incorporates the following Temporary Changes:

following Temporary-Changes:

N/A N/A LIST OF PAGES (all pages rev'd to Rev.

9) 1.0 to 3.0 EI-i E2-1 to E2-3 E3-1 E4-1 to E4-2 E5-1 to E5-7 E6-1 to E6-3 E7-1 to E7-3 E8-1 to E8-2 E9-1 El0-1 to El0-4 El1-1 E12-1 to E12-4 El3-1 E14-1 to E14-2 E15-1 to E15-2 E16-1 to E16-2 OYSTER CREEK CONTROLLED DISTRIBUTION J17 DOCUMENT SERIAL NUMBER SRMC

_Signatue Concurring Organization Element Date Originator EOP COORDINATOR 3129-/P Concurred By (Z* *-

L_*

EOP COMMITTEE DIRECTOR EQUIPMENT RELIABILITY PLANT OPERATIONS DIRECTOR A -

c, Approved By_

yIRECTOR, OPERATIONS & MAINT.

-i

-D6O (320001A) 1.0

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.01A NUCLEAR Title Revision No.

RPV CONTROL - NO ATWS 9

1.0 PURPOSE The purpose of the RPV Control -

No ATWS Procedure is to:

"* Maintain adequate core cooling

"* Cooldown the RPV to cold shutdown conditions

2.0 REFERENCES

2.1 Procedures 107.4, EOP Program Control

308, Emergency Core Cooling System Operation 2.2 Drawings BR 2002, Main, Extraction & Aux Steam System BR 3029, DC Control Elem Diagram BR E1102, Emer Condenser Isol Outlet Valve V-14-35 BR E1183, Elem Diagram for Cleanup Isolation Valve V-16-2 BR E1184, Elem Diagram for Cleanup Isolation Valve V-16-14 GE 112C2248, Sht 2, Connection Diagram 11F GE 148F262, P&ID -

Emergency Condenser System GE 148F444, P&ID -

Cleanup Demineralizer System GE 157B6350, Sht 153, Cleanup System AC Isol Valve Elem Diagram GE 237E566, Sht 4 Rx Protection System Elem Diagram 2.3 2000-GLN-3200.01, OC Plant Specific Technical Guidelines 2.4 2000-STD-1218.04, EOP Writer's Guide (320001A) 2.0

(

0OYSTER CREEK NUCLEAR GENERATING Number OGPU STATION PROCEDURE EMG-3200.01A NUCLEAR Title Revision No.

RPV CONTROL - NO ATWS 9

3.0 PRECAUTIONS AND LIMITATIONS 3.1 This procedure gives guidance to the operator for bypassing isolation signals scrams which is a departure from the Oyster Creek Technical Specifications.

It is permissible to take actions which depart from the plant's Technical Specifications during emergency conditions as authorized by 10 CFR 50.54(x).

4.0 ATTACHMENTS 4.1 Attachment A -

RPV Control -

No ATWS EOP Flowchart DWG: GU 3E-200-08-008 Sh 1 4.2 Attachment B Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment C

D E

F G

H I

J K

- Support Procedure and Isolations

- Support Procedure Support Procedure Support Procedure Support Procedure Support Procedure Level Control

- Support Procedure

- Support Procedure Support Procedure Support Procedure Spray System 1, Confirmation of Automatic Initiations 2,

3, 4,

5, 6,

Feed and Condensate System Operation CRD System Operation Operation of the Core Spray System Fire Water for RPV Water Level Control Condensate Transfer for RPV Water 7,

Liquid Poison for RPV Water Level Control 8,

Lineup for Condensate System Injection 9,

Lineup for Core Spray System Injection 10, Stopping Injection from the Core 4.12 Attachment L -

Support Procedure 11, Alternate Pressure Control -

Attachment Attachment M

N 4.15 -

Attachment P -

Isolation Condensers Support Procedure 12, Alternate Pressure Control EMRVs Support Procedure 13, Alternate Pressure Control -

Clean-up in Recirculation Mode Support Procedure 14, Alternate Pressure Control -

Clean-up in Letdown Mode Support Procedure 15, Alternate Pressure Control Isolation Condenser Tube Side Vents (320001A) 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.13 4.14 4.16 3.0

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.01A NUCLEAR Title Revision No.

RPV CONTROL - NO ATWS 9

ATTACHMENT A Attachment A to EMG-3200.01A, RPV Control -

NO ATWS, is the RPV Control -

NO ATWS EOP Flowchart, DWG: GU 3E-200-08-008, Sht 1, Rev.

3.

(320001A/S3)

E1-1

Procedure EMG-3200.01A Support Proc-I Rev.

9 Attachment B Page 1 of 3 SUPPORT PROCEDURE 1 CONFIRMATION OF AUTOMATIC INITIATIONS AND ISOLATIONS 1.0 PREREQUISITES Confirmation of automatic initiations and isolations has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE Confirm the following isolations/starts not required to by bypassed by the Emergency Operating Procedures:

(320001A/$4)

SYSTEM OPERATING DETAILS Reactor IF Any of the following conditions exist:

Isolation RPV water level at or below 86 in.

"* Steam tunnel temperature at or above 180*F

"* Any steam line flow at or above 4.0x106 Ibm/hr

"* Reactor mode switch in RUN and RPV pressure at or below 850 psig

"* Main steam line radiation at or above 800 units AND no ATWS condition exists THEN Confirm closed the following:

MSIVs IC VENTS RX SAMPLE NSO3A V-14-1,-19 V-24-30 (11F)

NS04A V-14-5,-20 V-24-29 (11F)

NS03B DW AIR SUPPLY NS04B V-6-395 (11F)

Scram IF A Reactor Scram is initiated Discharge AND Volume SDV HI-HI LVL SCRAM switch is not in

BYPASS, Isolation THEN Confirm closed the following:

NORTH SDV Vents & Drains SOUTH SDV Vents & Drains E2-1

Procedure EMG-3200.01A Support Proc-i Rev.

9 Attachment B Page 2 of 3 SYSTEM OPERATING DETAILS IC-A IF IC-A is

ruptured, Isolation THEN Confirm closed the following:

IC ISOLATION VALVES IC VENTS V-14-30 V-14-34 V-14-5 V-14-31 V-14-36 V-14-20 IC-B IF IC-B is ruptured, Isolation THEN Confirm closed the following:

IC ISOLATION VALVES IC VENTS V-14-32 V-14-35 V-14-1 V-14-33 V-14-37 V-14-19 Cleanup IF Any of the following conditions exist:

System 0

RPV water level at or below 86 in.

Isolation 0

Drywell pressure at or above 3.0 psig 0

RWCU HELB Alarms THEN Confirm closed the following Cleanup Isolation valves:

V-16-1 V-16-14 V-16-2 V-16-61 Shutdown IF Any of the following conditions exist:

Cooling RPV water level at or below 86 in.

System Drywell pressure at or above 3.0 psig Isolation THEN Confirm closed the following SDC Isolation Valves:

V-17-54 V-17-19 Isolation IF RPV water level is at or below 86 in.,

Condenser Initiation THEN confirm initiation of both Isolation Condensers.

Core Spray IF Any of the following conditions exist:

System RPV water level at or below 86 in.

Start 0 Drywell pressure at or above 3.0 psig THEN Confirm start of one Main Pump and one Booster Pump in each Core Spray System.

(320001A/S4)

E2-2

Procedure EMG-3200.01A Support Proc-I Rev.

9 Attachment B Page 3 of 3 SYSTEM Primary Containment Isolation OPERATING DETAILS

+

IF Any of the following conditions exist:

"* RPV water level at or below 86 in.

"* Drywell pressure at or above 3.0 psig THEN Confirm closed the following valves that are not required to be open by the Emergency Operating Procedures:

System Valve No.

DW Vent/Purge V-27-1 (Panel 11F)

Torus Vent Torus 2" Vi DWEDT ent Bypass DW Floor Sump Torus/Rx Bldg.

Vacuum Breakers TIP Valves DW 2" Vent Bypass N2 Purge N2 Makeup V-27-2 V-27-3 V-27-4 V-28-17 V-28-18 V-28-47 V-22-1 V-22-2 V-22-28 V-22-29 V-26-16 V-26-18 Common Ind.

V-23-21 V-23-22 V-23-13 V-23-14 V-23-15 V-23-16 V-23-17 V-23-18 V-23-19 V-23-20 (Panel 11F)

(Panel 1F)

(Panel 11F)

(Panel 11F)

(Panel 11F)

(Panel 11F)

(Panel 12XR)

(Panel 12XR)

(Panel 12XR)

(320001A/S4)

E2 -3

Procedure EMG-3200.01A Support Proc-2 Rev. 9 Attachment C Page 1 of 1 SUPPORT PROCEDURE 2 FEED AND CONDENSATE SYSTEM OPERATION 1.0 PREREQUISITES Directed to maintain RPV level with the Feed and Condensate Systems by the Emergency Operating Procedures.

2.0 PREPARATIONS None 3.0 PROCEDURE 3.1 IF RPV water level is increasing, THEN select one Feedwater Pump to be the operating pump and trip the Feedwater Pumps NOT selected.

3.2 Control RPV water level using the following:

"* Feedwater Regulating valves (Panel 5F/6F).

"* MFRV Block Valves (Panel 5F/6F).

"* Feedwater Low Flow valves (Panel 5F/6F).

"* Heater Bank Outlet Isolation valves (Panel 5F/6F).

"* Feedwater and Condensate pumps (Panel 5F/6F).

3.3 IF RPV water level cannot be maintained below 160 in.,

THEN close the Heater Bank Outlet Isolation valves for the operating pumps (Panel 5F/6F).

3.4 IF RPV water level reaches 170 in.,

THEN trip any operating Feedwater pump (Panel 5F/6F).

3.5 IF RPV water level reaches 170 in.

AND RPV pressure is below 350 psig (the shutoff head of the Condensate pumps),

THEN close all Heater Bank Outlet Isolation valves (Panel 5F/6F).

3.6 IF RPV water level continues to increase, THEN trip the operating Condensate Pumps (Panel 5F/6F).

(320001A/S5)

E3-1

Procedure EMG-3200.01A Support Proc-3 Rev.

9 Attachment D Page 1 of 2 SUPPORT PROCEDURE 3 CRD SYSTEM OPERATION 1.0 PREREQUISITES Directed to maintain RPV level with the CRD System by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE NOTE There are three methods of injection using the CRD system:

1.

Scram reset and controlling with the CRD Flow Control Valve (NC30).

2.

Post scram injection (with the scram not reset) through the CRDs.

3.

Post scram injection using bypass flow and controlling with the CRD Bypass Valve V-15-30.

3.1 Confirm running all available CRD Pumps (Panel 4F).

3.2 1

IF the scram has been reset, AND CRD bypass flow is not required (based on flow rate required),

THEN control CRD flow using the in-service Flow Control Valve NC-30 (Panel 4F).

(320001A/S6)

CAUTION Operating one CRD pump at greater than 150 gpm may result in a pump trip.

E4-1

3.3 IF THEN 3.4 IF THEN 3.5 IF THEN Procedure EMG-3200.01A Support Proc-3 Rev.

9 Attachment D Page 2 of 2 CRD bypass flow is reauired for RPV water level control, complete the following,

1. Confirm the scram reset.
2.

IF the scram cannot be reset, THEN close CRD Charging Header Supply Valve V-15-52 (RB 23).

3.

Open CRD Bypass Isolation Valve, V-15-237 (RB 23 SE)

4.

Monitor flow on Flow Gage FI-225-2 (RB 23 SE),

AND throttle open CRD Bypass Valve, V-15-30 (RB 23 SE),

so as not to exceed 150 gpm flow for one or two pump operation.

RPV water level cannot be maintained below 160 in.,

1. Throttle closed CRD Bypass Valve, V-15-30 (RB 23 SE),

if open.

2.

Throttle closed CRD Flow Control Valve (Panel 4F).

RPV water level reaches 170 in.,

trip the operating CRD pumps.

(Panel 4F).

(320001A/S6)

E4-2

Procedure EMG-3200.01A Support Proc-4 Rev.

9 Attachment E Page 1 of 7 SUPPORT PROCEDURE 4 OPERATION OF THE CORE SPRAY SYSTEM 1.0 PREREQUISITES Use of the Core Spray System for RPV level control has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 IF THEN 2.2 This 3.0 PROCEDURE' 3.1 Core Spray System actuating signals are present override the Core Spray initiation logic by depressing the OVERRIDE switches for all the sensors that are lit and depressing all ACTUATED switches, whether lit or unlit (Panel IF/2F).

procedure requires the use of an MB-l and PA-235 key.

IF Bus 1C or 1D are being supplied by an Emergency Diesel Generator, THEN verify that adequate load margin is available so as NOT to exceed EDG load limit when starting Core Spray Pumps.

(320001A/S7)

NOTE Manual control of the core spray system after auto initiation can only be accomplished after all initiating signals are overridden and the logic is reset.

CAUTION Core Spray suction strainer plugging may occur due to debris in the Primary Containment and result in a loss of Core Spray System Flow.

CAUTION Diesel Generator overload will result if a Core Spray Main and Booster Pump are started with a Diesel Generator load of greater than 2000 KW.

E5-1

Procedure EMG-3200.01A Support Proc-4 Rev.

9 Attachment E Page 2 of 7 3.2 CAUTION NPSH problems will develop on all operating pumps if more than 4 Containment Spray/Core Spray Main pumps are operated at the same time.

IF 4 Containment Spray/Core Spray Main pumps are in operation, THEN secure Containment Spray pumps as necessary to run Core Spray pumps.

3.3 Confirm one Core Spray Main Pump is running in each system (Panel IF/2F).

3.4 WHEN Core Spray Main Pump discharge pressure increases above 105 psig (Sys 1) or 140 psig (Sys 2)

(Panel IF/2F),

THEN confirm a Core Spray Booster Pump in each system is operating (Panel IF/2F).

3.5 WHEN RPV pressure is less than 310 psig, THEN restore and maintain RPV water level in a band directed by the GSS/GOS, by cycling the Core Spray Parallel Isolation Valves as required (Panel IF/2F).

3.6 Observe the NPSH and Vortex limits of Figures A and B.

3.6.1 Maintain Core Spray.Pump flow less than Figure B.

3.6.2 Maintain total Core Spray and Containment Spray flow less than Figure A.

3.7 IF all Core Spray pumps that are running are not required to assure adequate core cooling, THEN

1. inform the GOS/GSS,
2.

secure the Core Spray pumps that are not required to assure adequate core cooling.

(320001A/S7)

E5-2

Procedure EMG-3200.01A Support Proc-4

.Rev.

9 Attachment E Page 3 of 7 3.8 IF THEN 3.9 3.10 no Core Spray pumps in a system are operating, verify Core Spray KEEP FILL TROUBLE (B-3-d) alarm is not illuminated.

NOTE Core Spray System pumps will operate on minimum recirculation flow when the Parallel Isolation Valves are closed.

IF the Core Spray pumps are operated for greater than 30 minutes on minimum recirculation flow, AND conditions permit, THEN dispatch an operator to check the operating Core Spray pumps for excess vibration.

NOTE The Test Flow Return Valves throttle in the open direction only.

IF Core Spray Parallel Isolation Valves are required to be cycled to maintain RPV level for a time period in excess of two (2)

hours, THEN increase Core Spray System flow by completing the following:
1.

Unlock and place the breaker for the Test Flow Return Valve in the ON position.

"* System 1 V-20-27 (MCC lA21B/RB 23 E)

"* System 2 V-20-26 (MCC IB21A/RB 23 NE)

(320001A/S7)

E5-3

Procedure EMG-3200.01A Support Proc-4 Rev.

9 Attachment E Page 4 of 7

2.

Throttle open the Test Flow Return Valve and increase system flow to greater than 2000 gpm.

"* System 1 V-20-27 (Keylock RB 51 NW)

"* System 2 V-20-26 (Keylock RB 75 SW)

3.

Throttle the Test Flow Return Valve as required to maintain total Core Spray Flow (per system) 2000 to 5000 gpm and RPV water level as directed by the GSS/GOS.

3.11 Continue to monitor Core Spray System operation and evaluate system performance in accordance with Steps 3.6 through 3.10.

(320001A/$7)

E5-4

Procedure EMG-3200.01A Support Proc-4 Rev.

9 Attachment E Page 5 of 7 FIGURE A CORE SPRAY VORTEX LIMIT 100 90 80 70 TORUS LEVEL (IN) 60 50 40 30 0

2 4

6 8

10 12 14 16 18 20 TOTAL CORE SPRAY AND CONTAINMENT SPRAY FLOW (XIOO0 GPM)

(320001A/S7)

E5-5

Procedure EMG-3200.01A Support Proc-4 Rev. 9 Attachment E Page 6 of 7 Torus Temperature 170 (F) 160 150 140 130 120 FIGURE B CORE SPRAY NPSH LIMIT 3000 3500 4000 4500 Pump Flow (gpm)

A I

H G

STATIC HEAD ADJUSTMENT F

FROM FIG. C E

D 5OOO B

C 230 220 210 200 190 180 Torus Temperature 170 (F) 160 150 140 130 120 110 2500 3000 3500 4000 Pump Flow (gpm)

I H

G F

STATIC E

HEAD ADJUSTMENT FROM D

FIG. C C

4500 A B 5000 (320001A/S7) 230 -

220 4-210 +-

200 4-1904-180 -

110 4 2500 E5-6

Procedure EMG-3200.01A Support Proc-4 Rev.

9 Attachment E Page 7 of 7 FIGURE C CORE AND CONTAINMENT SPRAY STATIC HEAD CURVE H

4

" E CL 0

LA "0

-1

-2

-3 100 110 120 130 140 150 160 170 180 Torus Water Level (in) 0.5

-0.5

-2.5 190 200 PSTRAINER VALUE TOTAL (TORUS)

PSTRAINER FLOW (PSL)

(GPM)

< 5000 0.3 5000 -

7500 0.5 7500 -

10000 0.8 10000 -

12500 1.2 12500 -

15000 1.6 15000 -

17500 2.1 17500 -

18400 2.3 18400 -

20000 2.7 (320001A/S7)

I E5-7

Procedure EMG-3200.01Al Support Proc-5 Rev.

9 Attachment F Page 1 of 3 SUPPORT PROCEDURE 5 FIRE WATER FOR RPV WATER LEVEL CONTROL 1.0 PREREQUISITES RPV water level control using Fire Water via the Core Spray System has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 IF Core Spray actuating signals are present, THEN override Core Spray initiation logic by depressing the OVERRIDE switches for all the sensors that are lit and depressing all ACTUATED switches, whether lit or unlit.

3.0 PROCEDURE 3.1 NOTE Overriding Core Spray initiation logic may be required.

IF Core Spray System 1 is designated to be used, THEN inject fire water as follows:

3.1.1 Confirm stopped the Core Spray Main and Booster Pumps on Core Spray System 1 (Panel IF/2F).

3.1.2 Place the Core Spray System 1 Main Pump control switches in the PULL-TO-LOCK position (Panel IF/2F).

3.1.3 Close Tell-Tale Drain Valve, V-20-91 (RB 23 North or North Side RB outside).

3.1.4 Confirm running all Diesel Fire Pumps by placing their control switches in MAN position (Panel 13R).

3.1.5 Open Fire Water Supply Valve, V-20-83 (RB 23 North or North Side RB outside).

3.1.6 Confirm open Core Spray System 1 Discharge Valve, V-20-12 (Panel IF/2F).

(320001A/$8)

E6-1

Procedure EMG-3200.01A Support Proc-5 Rev.

9 Attachment F Page 2 of 3 3.1.7 Confirm closed Core Spray System 1 Test Flow Return Valve, V-20-27 (Panel IF/2F).

3.1.8 Close Core Spray System 1 Pump Suction Valves, V-20-32 and V-20-3 (Panel IF/2F).

3.1.9 WHEN directed by the GSS/GOS THEN open either Core Spray System 1 Parallel Isolation Valve, V-20-15 or V-20-40 (Panel IF/2F).

3.2 NOTE Overriding Core Spray initiation logic may be required.

IF Core Spray System 2 is designated to be used, THEN inject fire water as follows:

3.2.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 2 (Panel IF/2F).

3.2.2 Place the Core Spray System 2 Main Pump control switches in the PULL-TO-LOCK position (Panel IF/2F).

3.2.3 Close Tell-Tale Drain Valve, V-20-90 (RB 23 South, or South Side RB outside).

3.2.4 Confirm running all Diesel Fire Pumps by placing their control switches in MAN position (Panel 13R).

(320001A/S8)

E6-2

Procedure EMG-3200.01A Support Proc-5 Rev.

9 Attachment F Page 3 of 3 3.2.5 Open Fire Water Supply Valve, V-20-82 (RB 23 South or South Side RB outside).

3.2.6 Confirm open Core Spray System 2 Discharge Valve, V-20-18 (Panel 1F/2F).

3.2.7 Confirm closed Core Spray System 2 Test Flow Return Valve, V-20-26, (Panel lF/2F).

3.2.8 Close Core Spray System 2 Pump Suction Valves, V-20-33 and V-20-4 (Panel IF/2F).

3.2.9 WHEN directed by the GSS/GOS THEN open either Core Spray System 2 Parallel Isolation Valve, V-20-21 or V-20-41 (Panel IF/2F).

(320001A/$8)

E6-3

Procedure EMG-3200.01A Support Proc-6 Rev.

9 Attachment G Page 1 of 3 SUPPORT PROCEDURE 6 CONDENSATE TRANSFER FOR RPV WATER LEVEL CONTROL 1.0 PREREQUISITES The use of the Condensate Transfer System via the Core Spray System for RPV water level control has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 This procedure requires the use of an MB-l key and access to the Rx. Bldg.

2.2 IF Core Spray actuating signals are present, THEN override Core Spray initiation logic by depressing the OVERRIDE switches for all the sensors that are lit and depressing all ACTUATED switches, whether lit or unlit.

3.0 PROCED 3.1

)URE NOTE Overriding Core Spray initiation logic may be required.

IF Core Spray System 1 pumps are not available, AND Fire Water to Core Spray System 1 is not in service, THEN inject Condensate Transfer via the Core Spray System as follows:

3.1.1 Confirm stopped the Core Spray Main and Booster pumps in Core Spray System 1.

3.1.2 Place the Core Spray System 1 Main Pump control switches in PULL-TO-LOCK position.

3.1.3 Unlock and open Regulator Bypass Valves, V-11-110 and V-Ill (RB 51 NW)

(320001A/$9)

E7-1

Procedure EMG-3200.01A Support Proc-6 Rev.

9 Attachment G Page 2 of 3 3.1.4 Confirm open Core Spray System 1 Discharge Valve, V-20-12 (Panel IF/2F).

3.1.5 Confirm closed Core Spray System 1 Test Flow Return Valve, V-20-27 (Panel IF/2F).

3.1.6 Start all available Condensate Transfer Pumps (Panel 5F/6F).

3.1.7 Close Core Spray System 1 Pump Suction Valves V-20-32 and V-20-3 (Panel IF/2F).

3.1.8 WHEN directed by the GSS/GOS, THEN open either Core Spray System 1 Parallel Isolation Valve, V-20-15 or V-20-40 (Panel lF/2F).

3.2 NOTE Overriding Core Spray initiation logic may be required.

IF Core Spray System 2 pumps are not available, AND Fire Water to Core Spray System 2 is not in service, THEN inject Condensate Transfer via the Core Spray System as follows:

3.2.1 Confirm stopped the Core Spray Main and Booster pumps in Core Spray System 2.

3.2.2 Place Core Spray System 2 Main Pump control switches in the PULL-TO-LOCK position.

3.2.3 Unlock and open Regulator Bypass Valves, V-11-109 and V-I1-108 (RB 75 S).

3.2.4 Confirm open Core Spray System 2 Discharge Valve, V-20-18 (Panel IF/2F).

(320001A/S9)

E7-2

Procedure EMG-3200.01A Support Proc-6 Rev.

9 Attachment G Page 3 of 3 3.2.5 Confirm closed Core Spray System 2 Test Flow Return Valve, V-20-26 (Panel lF/2F).

3.2.6 Start all available Condensate Transfer Pumps (Panel 5F/6F).

3.2.7 Close Core Spray System 2 Pump Suction Valves V-20-33 and V-20-4 (Panel lF/2F).

3.2.8 WHEN directed by the GSSIGOS, THEN open either Core Spray System 2 Parallel Isolation Valve, V-20-21 or V-20-41 (Panel IF/2F).

(320001A/$9)

E7-3

Procedure EMG-3200.01A Support Proc-7 Rev.

9 Attachment H Page 1 of 2 SUPPORT PROCEDURE 7 LIQUID POISON FOR RPV WATER LEVEL CONTROL 1.0 PREREQUISITES RPV water level control using the Standby Liquid Control System has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 This procedure requires the use of an MB-I key.

3.0 PROCEDURE 3.1 IF Rx building 95 Ft. elevation is accessible AND time

permits, THEN perform the following to lineup Demineralized Water for injection via the SLC System:

3.1.1 Unlock and close Standby Liquid Control Tank Outlet Valve V-19-4, (RB 95 West).

3.1.2 Unlock and open Test Tank Outlet Valve V-19-11, (RB 95 West).

3.1.3 Fill test tank by performing the following:

1. Open Demin Water Isolation Valve V-12-14 (RB 95 West).
2.

Open Test Tank Demin Water Supply Valve V-19-12 (RB 95 West).

3.1.4 Inform the GSS/GOS that Demineralized Water has been lined up to the SLC System.

3.2 WHEN directed by the GSS/GOS, THEN start SLC Pump A by placing the STANDBY LIQUID CONTROL Keylock in the FIRE SYS 1 position (Panel 4F).

(320001A/Sl0)

CAUTION Due to pressure fluctuations, Fuel Zone Level Indictor Channels 'A; and 'C' will not provide accurate indication of RPV water level if a Standby Liquid Control Pump is injecting into the RPV and should not be used.

E8-1

Procedure EMG-3200.01A Support Proc-7 Rev.

9 Attachment H Page 2 of 2 3.3 IF Pump A does NOT start OR System 1 Squib Valve does NOT fire THEN start SLC Pump B by placing the STANDBY LIQUID CONTROL Keylock in the FIRE SYS 2 position (Panel 4F).

3.4 Monitor system parameters for proper system performance.

3.5 IF Demineralized Water is being used for injection, THEN throttle Test Tank Demin Water Supply Valve V-19-12 (RB 95 West) as required to maintain a constant level in the Test Tank.

(320001A/SIO)

E8-2

Procedure EMG-3200.01A Support Proc-8 Rev.

9 Attachment I Page 1 of 1 SUPPORT PROCEDURE 8 LINEUP FOR CONDENSATE SYSTEM INJECTION 1.0 PREREQUISITES Confirmation of the lineup for Condensate System injection has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Confirm open:

(on Panel 5F/6F)

"* HEATER BANK INLET Valves V-2-7 V-2-8 V-2-9

"* HEATER BANK OUTLET Valves V-2-10 V-2-11 V-2-12

"* MFRV A BLOCK Valve V-2-740

"* MFRV C BLOCK Valve V-2-741 3.2 Confirm all available Condensate Pumps running.

A B

C 3.3 Confirm 2 Condensate Demineralizers are in service for each operating Condensate Pump 3.4 Confirm all Feedwater Regulating Valve Controllers in MAN position.

ID11A ID11B IDIIC 3.5 Confirm all Feedwater Regulating Valves open.

A B

c (320001A/Sll)

E9-1

Procedure EMG-3200.01A Support Proc-9 Rev. 9 Attachment J Page 1 of 4 SUPPORT PROCEDURE 9 LINEUP FOR CORE SPRAY SYSTEM INJECTION 1.0 PREREQUISITES Confirmation of the lineup for Core Spray System injection has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE CAUTION Core Spray suction strainer plugging may occur due to debris in the Primary Containment and result in a loss of Core Spray System Flow.

3.1 Confirm open Core Spray System 1 and 2 Pump Suction Valves (Panel lF/2F).

V-20-32 V-20-3 V-20-33 V-20-4 3.2 Confirm closed Core Spray System 1 and 2 Test Flow Return Valves in each system (Panel IF/2F).

V-20-27 V-20-26 3.3 CAUTION NPSH problems will develop"on all operating pumps if more than 4 Containment Spray/Core Spray Main pumps are operated at the same time.

IF 4 Containment Spray/Core Spray Main pumps are in operation, THEN secure Containment Spray pumps as necessary to run Core Spray pumps.

3.4 Confirm one Core Spray System Main Pump operating in each system (Panel lF/2F).

NZ01A NZ01C NZ01B NZ01D (320001A/S12)

E10-1

Procedure EMG-3200.01A Support Proc-9 Rev.

9 Attachment J Page 2 of 4 3.5 Confirm one Core Spray System Booster Pump operating in each system (Panel IF/2F).

3.6 Confirm open Core Spray System 1 and 2 Discharge Valves (Panel IF/2F).

NZ03A NZ03C N5Z03B NZ03D V-20-12 V-20-18 3.7 WHEN THEN RPV pressure decreases to 310 psig, confirm open at least one Core Spray Parallel Isolation Valve in each System (Panel IF/2F),

V-20-15 V-20-40 V-20-21 V-20-41 NOTE Maximum Flow is achieved with one main pump and one booster pump running and both parallel isolation valves open in each system.

3.8 Maximize system flow irregardless of Vortex limits AND Maintain Core Spray NPSH limits in accordance with Figure B.

3.9 IF NPSH limits are reached, THEN secure the booster pump in the system with NPSH limitation.

(320001A/S12)

E10-2

Procedure EMG-3200.01A Support Proc-9 Rev.

9 Attachment J Page 3 of 4 190 180 Torus Temperature 170 (F) 160 120 FIGURE B CORE SPRAY NPSH LIMIT 3000 3500 4000 4500 Pump Flow (gpm)

A I

H G

STATIC HEAD ADJUSTMENT F

FROM FIG. C E

D 5000 B

C 230 220 -

210 4-200 +4-190 4-180 -.-

Torus Temperature 170 (F) 160 150 140 130 120 110 -k 2500 3000 3500-4000 Pump Flow (gpm)

I H

G F

STATIC E

HEAD ADJUSTMENT FROM D

FIG. C C

4500 A B 5000 (320001A/S12) 230 'r-220.*-

210 4-200 1-2500 4At%

E10-3

Procedure EMG-3200.01A Support Proc-9 Rev.

9 Attachment J Page 4 of 4 FIGURE C CORE AND CONTAINMENT SPRAY STATIC HEAD CURVE

5.

4 3

z E

0 I-C 1.5 0.5

-0.5

-1.5

-1

-2 2.5

-3 100 110 120 130 140 150 160 170 180 190 200 Torus Water Level (in)

PSTRAINER VALUE TOTAL (TORUS)

PSTRAINER FLOW (PSL)

(GPM)

< 5000 0.3 5000 -

7500 0.5 7500 -

10000 0.8 10000 -

12500 1.2 12500 -

15000 1.6 15000 -

17500 2.1 17500 -

18400 2.3 18400 -

20000 2.7 (320001A/S12)

E10-4

Procedure EMG-3200.01A Support Proc-10 Rev.

9 Attachment K Page 1 of 1 SUPPORT PROCEDURE 10 STOPPING INJECTION FROM THE CORE SPRAY SYSTEM 1.0 PREREQUISITES Stopping Core Spray injection has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE When directed by the GOS/GSS, perform the following:

3.1 Depress the OVERRIDE switches for all sensors that are lit (Panel IF/2F).

3.2 Depress ALL ACTUATED switches whether lit or unlit (Panel lF/2F).

3.3 Confirm closed Core Spray Parallel Isolation Valves NOT required to be open to assure adequate core cooling.

3.4 Secure Core Spray Booster Pumps NOT required to assure adequate core cooling by placing their respective control switch in STOP (Panel IF/2F).

3.5 Secure Core Spray Main Pumps NOT required to assure adequate core cooling by placing their respective control switch in STOP (Panel lF/2F).

3.6 Verify Core Spray KEEP FILL TROUBLE (B-3-d) alarm is NOT illuminated.

(320001A/S13)

E11-1

Procedure EMG-3200.01A Support Proc--l Rev.

9 Attachment L Page 1 of 4 SUPPORT PROCEDURE 11 ALTERNATE PRESSURE CONTROL SYSTEMS ISOLATION CONDENSERS 1.0 PREREQUISITES RPV pressure control using the Isolation Condensers has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Procedure for Isolation Condenser A 3.1.1 Confirm Recirculation Pump A tripped.

IF recirculation Pump A cannot be tripped from the Control Room, THEN trip the recirculation Pump A Supply Breaker locally at 4160V Bus 1A.

3.1.2 CAUTION If RPV water level exceeds 180 in.,

initiation of an isolation condenser can cause water hammer to occur.

Verify RPV water level is below 160 in.

3.1.3 IF Isolation Condenser A has isolated on a high flow condition caused by Recirculation Pump operation, THEN restore the IC to operation as follows:

1. Open Steam Supply valves V-14-30 & V-14-31 by placing their control switches in the OPEN position (Panel IF/2F).

(320001A/S14)

E12-1

Procedure EMG-3200.01A Support Proc-ll Rev.

9 Attachment L Page 2 of 4

2.

Open DC Condensate Return valve V-14-34 by placing its control switch in the OPEN position (Panel IF/2F).

3.

Open AC Condensate Return valve V-14-36 by placing its control switch in the OPEN position (Panel lF/2F).

4.

Reset the Isolation Condenser isolation signal using the Isolation Condenser Reset pushbutton (Panel 4F).

5.

Restore all Isolation Condenser A valve control switches to their AUTO position.

3.1.4 Confirm open DC condensate return valve V-14-34 (Panel IF/2F).

3.1.5 Control RPV pressure in specified band by cycling V-14-34.

3.1.6 Make up to IC shell to maintain IC level between 4.8 ft.

and 7.7 ft.

by cycling Isolation Condenser A Make-Up Valve V-I1-36 (Panel 5F/6F).

(320001A/S14)

E12-2

Procedure EMG-3200.01A Support Proc--l Rev.

9 Attachment L Page 3 of 4 3.2 Procedure For Isolation Condenser B 3.2.1 Confirm Recirculation Pump E tripped.

IF recirculation Pump E cannot be tripped from the Control Room, THEN trip the recirculation Pump E supply breaker locally at 4160V Bus 1A.

3.2.2 CAUTION If RPV water level exceeds 180 in.,

initiation of an isolation condenser can cause water hammer to occur.

Verify RPV water level is below 160 in.

3.2.3 IF Isolation Condenser B has isolated on a high flow condition caused by Recirculation Pump operation, THEN restore the IC to operation as follows:

1. Open Steam Supply valves V-14-32 & V-14-33 by placing their control switches in the OPEN position (Panel IF/2F).
2.

Open DC Condensate Return valve V-14-35 by placing its control switch in the OPEN position (Panel IF/2F).

3.

Open AC Condensate Return valve V-14-37 by placing its control switch in the OPEN position (Panel IF/2F).

(320001A/S14)

E12-3

Procedure EMG-3200.01A Support Proc-li Rev.

9 Attachment L Page 4 of 4

4.

Reset the Isolation Condenser isolation signal using the Isolation Condenser Reset pushbutton (Panel 4F).

5.

Restore all Isolation Condenser B valve control switches to their AUTO position.

3.2.4 Confirm open DC condensate return valve V-14-35 (Panel IF/2F).

3.2.5 Control RPV pressure in specified band by cycling V-14-35.

3.2.6 Make up to IC shell to maintain IC level between 4.8 ft.

and 7.7 ft.

by cycling Isolation Condenser B Make-Up Valve V-11-34 (Panel 5F/6F).

(320001A/S14)

E12-4

Procedure EMG-3200.01A Support Proc-12 Rev.

9 Attachment M Page 1 of 1 SUPPORT PROCEDURE 12 ALTERNATE PRESSURE CONTROL SYSTEMS EMRVs 1.0 PREREQUISITES RPV pressure control using the EMRVs has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Verify that Torus water level is above 90 in.

3.2 Place the selected EMRV control switch in the MAN position (Panel IF/2F).

3.3 Control reactor pressure in the specified band by opening the EMRVs in the following sequence:

NR108A NR108D NR108B NR108C NR108E 3.4 Monitor Torus water temperature.

(320001A/S15)

E13-1

Procedure EMG-3200.01A Support Proc-13 Rev.

9 Attachment N Page 1 of 2 SUPPORT PROCEDURE 13 ALTERNATE PRESSURE CONTROL SYSTEMS CLEAN-UP IN RECIRCULATION MODE 1.0 PREREQUISITES 1.1 RPV pressure control using the Reactor Water Cleanup System in Recirculation Mode has been directed by the Emergency Operating Procedures.

1.2 No RWCU HELB exists.

2.0 PREPARATION When directed by GSS/GOS, perform the following:

2.1 Confirm that a Cleanup System line break does not exist (Alarms D-l-d/D-2-d).

2.2 Open the EOP BYPASS PLUGS panel in the rear of Panel 3F.

2.2.1 Remove the bypass plug from position BP2 and insert into position BPI.

2.2.2 Remove the bypass plug into position BP3.

2.2.3 Remove the bypass plug into position BP5.

2.2.4 Remove the bypass plug into position BP7.

2.3 Obtain a flat head screwdriver in the Control Room.

from position BP4 and insert from position BP6 and insert from position BP8 and insert from the EOP Tool Box 2.4 Open the front panel of Auxiliary Relay Panel ER-215-087 (A/B Battery Room).

2.4.1 Remove bypass plug 1 (upper left hand corner).

2.4.2 Remove bypass plug 2 (upper left hand corner).

(320001A/S16)

E14-1

Procedure EMG-3200.01A Support Proc-13 Rev.

9 Attachment N Page 2 of 2 3.0 PROCEDURE When directed by the GSS/GOS, perform the following 3.1 Bypass and isolate Cleanup Filters as follows:

3.1.1 Open V-16-83, Filter Bypass Valve (RB 75).

3.1.2 Close Filter Outlet Valve ND28A or ND28B (RB 75).

3.2 NOTE The remote valve operators to valves V-16-102, V-16-113, and V-16-114 have been disconnected.

Bypass and isolate the Cleanup Demineralizer:

3.2.1 Open Demineralizer Bypass Valve V-16-113 (RB 75 SW).

3.2.2 Close Demineralizer Outlet Valve V-16-114 (RB 75 SW).

3.2.3 Close Demineralizer Inlet Valve V-16-102 (RB 75 SW).

3.3 IF Cleanup System is not in service THEN place the system in service in accordance with Procedure 303, Reactor Cleanup Demineralizer System.

3.4 Maximize RBCCW flow to the Non-Regenerative Heat Exchanger.

Maximum flow allowed is 1750 gpm.

3.5 Maintain RPV pressure within desired band by throttling RBCCW flow to the NRHX.

(320001A/S16)

E14-2

Procedure EMG-3200.01A Support Proc-14 Rev.

9 Page 1 of 2 SUPPORT PROCEDURE 14 ALTERNATE PRESSURE CONTROL SYSTEMS CLEAN-UP IN LETDOWN MODE 1.0 PREREQUISITES 1.1 RPV pressure control using the Reactor Water Cleanup System in Letdown Mode has been directed by the Emergency Operating Procedures.

1.2 Boron Injection is not required.

1.3 No RWCU HELB exists.

2.0 PREPARATIONS None 3.0 PROCEDURE 3.1 Confirm that a Cleanup System line break does not exist (Alarms D-l-d/D-2-d).

3.2 IF Cleanup System is not in service, THEN place the system in service in accordance with Procedure 303, Reactor Cleanup Demineralizer System.

3.3 Confirm closed the following valves:

"* Discharge to Radwaste V-16-57 (Panel 3F).

"* Discharge to Condenser V-16-60 (Panel 3F).

"* Discharge Flow Controller FCV-ND-22 (Panel 3F).

3.4 Open Discharge to Condenser Valve V-16-60 (Panel 3F).

3.5 Commence Letdown Flow to the main condenser by throtting open Discharge Flow Controller FCV-ND-22 (Panel 3F).

3.6 Carefully monitor Cleanup System Flow and make necessary adjustments with System Flow Controller FCN-ND-16 (Panel 3F) to maintain proper differential pressures across demineralizer and filter elements.

3.7 Maintain NRHX outlet temperature below 130 2 F by either reducing Letdown Flow using FCV-ND-22 (Panel 3F) or increasing RBCCW Flow through the NRHX using valve V-5-122 (RB 51 SE).

Maximum RBCCW Flow allowed is 1750 gpm.

3.8 Adjust letdown flow rate by throttling FCV-ND-22 to establish required cooldown rate or pressure band.

(320001A/S17)

E15-1

Procedure EMG-3200.01A Support Proc-14 Rev. 9 Page 2 of 2 3.9 IF NRHX outlet temperature cannot be maintained less than 1302F AND the system trips, THEN

1. Bypass and isolate the Cleanup Filter:
a.

Open V-16-83, Filter Bypass Valve (RB 75).

b.

Close Filter Outlet Valve ND28A or ND28B (RB 75).

2.

NOTE The remote valve operators to valves V-16-102, V-16-113, and V-16-114 have been disconnected.

Bypass and isolate the Cleanup Demineralizer:

a.

Open Demineralizer Bypass Valve V-16-113 (RB 75 SW).

b.

Close Demineralizer Outlet Valve V-16-114 (RB 75 SW).

c.

Close Demineralizer Inlet Valve V-16-102 (RB 75 SW).

3.

Contact I & C Department to inhibit the NRHX outlet high temperature as follows:

a.

At RK05 (75' Elev.), rotate the dial on TIS-1J33 counterclockwise until the maximum trip setting is obtained.

4.

Return the Cleanup System to service in accordance with Procedure 303, Reactor Cleanup Demineralizer System.

5.

Perform Steps 3.3 through 3.6 to establish letdown flow.

6.

Adjust letdown flow rate by throttling FCV-ND-22 to establish required cooldown rate or pressure band.

(320001A/S17)

E15-2

Procedure EMG-3200.01A Support Proc-15 Rev.

9 Attachment P Page 1 of 2 SUPPORT PROCEDURE 15 ALTERNATE PRESSURE CONTROL SYSTEMS IC TUBE SIDE VENTS 1.0 PREREQUISITES RPV pressure control using the Isolation Condenser Tube Side Vents has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following in preparation for using the IC Tube Side Vents for RPV pressure control.

2.1 Verify the following:

1.

Isolation Condensers are not required to be isolated.

2.

Main Condenser is intact.

3.

Offsite radioactivity release rate is expected to remain below the release rate which requires an Unusual Event.

2.2 Confirm that the Isolation Condenser Vent Valve control switches for the Isolation Condensers to be used are in the normal mid-position (Panel 11F).

Isolation Condenser A V-14-5 V-14-20 Isolation Condenser B V-14-1 V-14-19 2.3 Open the EOP BYPASS PLUGS panel inside of Panel 1OXF.

2.3.1 Remove the bypass plug from position BP2 and insert it into position BPI.

2.3.2 Remove the bypass plug from position BP4 and insert it into position BP3.

(320001A/S18)

E16-1

Procedure EMG-3200.01A Support Proc-15 Rev.

9 Attachment P Page 2 of 2 3.0 PROCEDURE 3.1 Verify that RPV Water Level is below 180 in.

3.2 Confirm open the Isolation Condenser Steam Inlet Valves (IF/2F) for the Isolation Condensers to be used.

Isolation Condenser A V-14-30 V-14-31 Isolation Condenser B V-14-32 V-14-33 3.3 Open the Isolation Condenser Tube Side Vents (Panel 11F) for the Isolation Condensers to be used.

Isolation Condenser A V-14-5 V-14-20 Isolation Condenser B V-14-1 V-14-19 3.4 Control Reactor pressure in specified band by cycling the tube side vents designated in Step 3.3.

(320001A/SIS)

E16-2

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.01B NUCLEAR Title Revision No.

RPV CONTROL - WITH ATWS 9

Applicability/Scope Responsible Office SYSTEMS ENGINEERING EMERGENCY OPERATING PROCEDURE FOR OYSTER CREEK E150 This document is within QA plan scope X Yes No Safety Reviews Required X Yes No Prior Revision 8

incorporated the This Re' following Temporary Changes:

followi]

N/A Effective Date (04/25/00) 05/05/00 vision 9

incorporates the ng Temporary Changes:

N/A LIST OF PAGES (all pgs. rev'd to Rev. 9) 1.0 to 4.0 El-l E2-1 to E2-3 E3-1 E4-1 E5-1 to E5-2 E6-1 to E6-2 E7-1 to E7-5 E8-1 E9-1 to E9-4 El0-1 Ell-l to Eli-2 E12-1 to E12-2 E13-1 to E13-2 E14-1 to E14-6 E15-1 E16-1 to E16-7 E17-1 to E17-8 OYSTER CREEK CONTROLLED DISTRIBUTION f-7; DOCUMENT SERIAL NUMBER IRMC Signature, Concurring Organization Element Date Originator EOP COORDINATOR Concurred By EOP COMM4ITTEE ZL4L DIRECTOR EQUIPMENT RELIABILITY

________PLANT OPERATIONS DIRECTOR A*T Approved Approd MAINTENANCE (20001B) 1.0

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.01B NUCLEAR Title Revision No.

RPV CONTROL - WITH ATWS 9

1.0 PURPOSE The purpose of the RPV Control - With ATWS Procedure is to:

"* Maintain adequate core cooling

"* Shutdown the reactor

"* Cooldown the RPV to cold shutdown conditions

2.0 REFERENCES

2.1 Procedures 107.4, EOP Program Control

308, Emergency Core Cooling System Operation 2.2 Drawings BR 2002, Main, Extraction & Aux Steam System BR 2006, Flow Diagram Closed Cooling Water System BR 2011, Shts 1 & 2, Flow Diagram -

H&V Reactor Bldg.

BR 3029, DC Control Elem Diagram BR E1102, Emer Condenser Isol Outlet Valve V-14-35 BR E1183, Elem Diagram for Cleanup Isolation Valve V-16-2 BR E1184, Elem Diagram for Cleanup Isolation Valve V-16-14 GE 112C2248, Sht 2, Connection Diagram 11F GE 112C2654, Sht 3, Panel 2R Connection Diagram GE 148F262, P&ID -

Emergency Condenser System GE 148F444, P&ID -

Cleanup Demineralizer System GE 157B6350, Shts 117,

118, 153, Cleanup System AC Isol Valve Elem Diagram GE 237E566, Shts la, lb, 2, 4,

& 5, Rx Protection System Elem Diagram NU 5060E6003, Shts 1 -

3, Core Spray/RBCCW Drywell Isolation Elem Diagram (20001B) 2.0

(

0IOYSTER CREEK NUCLEAR GENERATING Number NU STATION PROCEDURE EMG-3200.01B NUCLEAR Title Revision No.

RPV CONTROL - WITH ATWS 9

2.3 2000-GLN-3200.01, OC Plant Specific Technical Guidelines 2.4 2000-STD-1218.04, EOP Writer's Guide 3.0 PRECAUTIONS AND LIMITATIONS 3.1 This procedure gives guidance to the operator for bypassing isolation signals and automatic scrams which is a departure from the Oyster Creek Technical Specifications.

It is permissible to take actions which depart from the plant's Technical Specifications during emergency conditions as authorized by 10 CFR 50.54(x).

4.0 ATTACHMENTS Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment RPV Control -

With ATWS EOP Flowchart DWG: GU 3E-200-08-009 Sht 1 Support Procedure 1, Confirmation of Automatic Initiations and Isolations Support Procedure 16, Bypassing MSIV LO-LO Level Isolation Interlocks Support Procedure 17, Termination and Prevention of Injection Support Procedure 18, Bypassing RBCCW Isolation Interlocks Support Procedure 19, Feedwater/Condensate and CRD System Operation Support Procedure 20, Low Pressure Injection During an ATWS

- Support Procedure 10, Stopping Injection from the Core Spray System Support Procedure 11, Alternate Pressure Control Systems - Isolation Condensers Support Procedure 12, Alternate Pressure Control Systems -

EMRVs Support Procedure 13, Alternate Pressure Control Systems-Clean-up in Recirculation Mode (20001B) 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 3.0

Attachment Attachment Attachment Attachment Attachment Attachment L

M N

0 P

Q Support Procedure 14, Alternate Pressure Control Systems - Clean-up in Letdown Mode Support Procedure 15, Alternate Pressure Control Systems -

I C Tube Side Vents Support Procedure 21, Alternate Insertion of Control Rods Support Procedure 22, Initiating the Liquid Poison System

- Support Procedure 23, Alternate Boron Injection with the Clean-up System

- Support Procedure 24, Alternate Boron Injection with the Feed & Condensate System (20001B)

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.01B NUCLEAR Title Revision No.

RPV CONTROL - WITH ATWS 9

4.12 4.13 4.14 4.15 4.16 4.17 4.0

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.01B NUCLEAR Title Revision No.

RPV CONTROL - WITH ATWS 9

ATTACHMENT A Attachment A to EMG-3200.01B, RPV Control - With ATWS is the RPV Control - With ATWS EOP Flowchart, DWG:

GU 3E-200-08-009, Sht 1, Rev.

3.

(20001B/S3)

E1-1

Reactor Isolation Procedure EMG-3200.01B Support Proc-i Rev.

9 Attachment B Page I of 3 SUPPORT PROCEDURE 1 CONFIRMATION OF AUTOMATIC INITIATIONS AND ISOLATIONS 1.0 PREREQUISITES Confirmation of automatic initiations and isolations has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE Confirm the following isolations/starts not required to by bypassed by the Emergency Operating Procedures:

OPERATING DETAILS SYSTEM IF Any of the following conditions exist:

"* RPV water level at or below 86 in.

"* Steam tunnel temperature at or above 1800,

"* Any steam line flow at or above 4.0x106 lbm/hr

"* Reactor mode switch in RUN and RPV pressure at or below 850 psig Main steam line radiation at or above 800 units AND no ATWS condition exists THEN Confirm closed the following:

MSIVs IC VENTS RX SAMPE NSO3A V-14-1,-19 V-24-30 NS04A V-14-5,-20 V-24-29 NS03B DW AIR SUP]

NS04B V-6-395 Scram IF A Reactor Scram is initiated Discharge AND Volume SDV HI-HI LVL SCRAM switch is not in BYPASS, Isolation THEN Confirm closed the following:

NORTH SDV Vents & Drains SOUTH SDV Vents & Drains IC-A IF IC-A is ruptured, Isolation THEN Confirm closed the following:

IC ISOLATION VALVES IC VENTS V-14-30 V-14-34 V-14-5 V-14-31 V-14-36 V-14-20 (20001B/$4)

LE (1I1F)

(I1IF)

PLY (11F)

E2-1

Procedure EMG-3200.01B Support Proc-i Rev.

9 Attachment B Page 2 of 3 SYSTEM OPERATING DETAILS IC-B IF IC-B is

ruptured, Isolation THEN Confirm closed the following:

IC ISOLATION VALVES IC VENTS V-14-32 V-14-35 V-14-1 V-14-33 V-14-37 V-14-19 Cleanup IF Any of the following conditions exist:

System 0

RPV water level at or below 86 in.

Isolation 0 Drywell pressure at or above 3.0 psig 0

RWCU HELB Alarms THEN Confirm closed the following Cleanup Isolation valves:

V-16-1 V-16-14 V-16-2 V-16-61 Shutdown IF Any of the following conditions exist:

Cooling RPV water level at or below 86 in.

System 0 Drywell pressure at or above 3.0 psig Isolation THEN Confirm closed the following SDC Isolation Valves:

V-17-54 V-17-19 Isolation IF RPV water level is at or below 86 in.,

Condenser Initiation THEN confirm initiation of both Isolation Condensers.

Core Spray IF Any of the following conditions exist:

System 0

RPV water level at or below 86 in.

Start 0

Drywell pressure at or above 3.0 psig THEN Confirm start of one Main Pump and one Booster Pump in each Core Spray System.

(20001B/S4)

E2-2

Procedure EMG-3200.01B Support Proc-I Rev.

9 Attachment B Page 3 of 3 SYSTEM IOPERATING DETAILS Primary Containment Isolation IF Any of the following conditions exist:

"* RPV water level at or below 86 in.

"* Drywell pressure at or above 3.0 psig THEN Confirm closed the following valves that are not required to be open by the Emergency Operating Procedures:

System Valve. No.

DW Vent/Purge Torus Vent Torus 2" DWEDT Vent Bypass DW Floor Sump Torus/Rx Bldg.

Vacuum Breakers TIP Valves DW 2" Vent Bypass N2 Purge N2 Makeup V-27-1 V-27-2 V-27-3 V-27-4 V-28-17 V-28-18 V-28-47 V-22-1 V-22-2 V-22-28 V-22-29 V-26-16 V-26-18 Common Ind.

V-23-21 V-23-22 V-23-13 V-23-14 V-23-15 V-23-16 V-23-17 V-23-18 V-23-19 V-23-20 (Panel 11F)

(Panel 11F)

(Panel 11F)

(Panel 11F)

(Panel 11F)

(Panel 11F)

(Panel 11F)

(Panel 12XR)

(Panel 12XR)

(Panel 12XR)

(20001B/S4)

E2-3 I

Procedure EMG-3200.01B Support Proc-16 Rev.

9 Attachment C Page 1 of 1 SUPPORT PROCEDURE 16 BYPASSING MSIV LO-LO LEVEL ISOLATION INTERLOCKS 1.0 PREREQUISITES Bypassing of the MSIV Lo-Lo level isolation interlocks has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Obtain four (4) bypass plugs from the EOP Tool Box in the Control Room.

3.2 Open the EOP BYPASS PLUGS panel in the rear of Panel 6R.

3.2.1 Insert a bypass plug in position BPI.

3.2.2 Insert a bypass plug in position BP2.

3.3 Open the EOP BYPASS PLUGS panel in the rear of Panel 7R.

3.3:1 Insert a bypass plug in position BPI.

3.3.2 Insert a bypass plug in position BP2.

3.4 Place the ISOL SIGNAL BYPASS V-6-395 switch in BYPASS position (Panel 11F).

3.5 Inform the GSS/GOS that the MSIV LO-LO Level Isolation Interlock has been bypassed.

(20001B/S5)

E3-1

Procedure EMG-3200.01B Support Proc-17 Rev.

9 Attachment D Page 1 of 1 SUPPORT PROCEDURE 17 TERMINATION AND PREVENTION OF INJECTION 1.0 PREREQUISITES Termination and prevention of injection has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 IF Core Spray actuating signals are present, THEN OVERRIDE Core Spray initiation logic by depressing the override switches for all the sensors that are lit and depressing all ACTUATED switches, whether lit or unlit.

3.0 PROCEDURE 3.1 Terminate and prevent Condensate and Feedwater injection by performing the following at Panel 5F/6F:

3.1.1 Trip all operating Feedwater Pumps.

3..1.2 Confirm one Condensate Pump running.

3.1.3 Place all individual FRV Controllers in MAN position.

3.1.4 Close all Feedwater Regulating Valves.

3.1.5 Close the Low Flow Valves.

3.2 NOTE Overriding Core Spray initiation logic may be required.

Terminate and prevent Core Spray injection by performing the following at Panel IF/2F:

3.2.1 Confirm all Core Spray Parallel Isolation Valve closed.

3.2.2 Confirm all operating Core Spray Booster Pumps tripped.

3.2.3 Confirm all Core Spray Main Pump control switches in PULL-TO-LOCK position.

3.3 Inform the operator controlling reactor pressure and the Licensed Operations Supervisor that the Isolation Condensers will initiate when RPV level reaches Io-Io water level.

(20001B/S6)

E4-1

Procedure EMG-3200.01B Support Proc-18 Rev. 9 Attachment E Page I of 2 SUPPORT PROCEDURE 18 BYPASSING RBCCW ISOLATION INTERLOCKS 1.0 PREREQUISITES Bypassing of the RBCCW isolation has been directed by the Emergency Operating Procedures AND the RBCCW system is NOT isolated due to a LOCA or Main Steam Line Break (MSLB) in the Drywell.

2.0 PREPARATION 2.1 NOTE After completing the following steps, Valves V-5-147, V-5-166 and V-5-167 will only operate from the Control Room.

All automatic operation is removed.

In the rear of Panel 2R, open the EOP BYPASS PLUGS panel.

2.1.1 Remove the bypass plug from position BPI.

2.1.2 Remove the bypass plug from position BP2.

3.0 PROCEDURE 3.1 CAUTION Reinitiating RBCCW flow to the Drywell following a LOCA or MSLB in the Drywell may cause a water hammer to occur and subsequent piping failure.

Verify that the RBCCW System is not isolated due to high Drywell pressure/low RPV water level conditions.

3.2 IF the RBCCW System is isolated due to high Drywell pressure/low RPV water level, THEN inform the Licensed Operations Supervisor and do not attempt to reinitiate the RBCCW System flow to the Drywell.

(20001B/S7)

E5-1

Procedure EMG-3200.01B Support Proc-18 Rev.

9 Attachment E Page 2 of 2 3.3 Confirm open RBCCW Isolation Valves (Panel IF/2F)

"* V-5-147

"* V-5-166

"* V-5-167

"* V-5-148 3.4 Start all available DW RECIRC FANS by placing their respective control switches in ON (Panel 11R).

3.5 Place the ISOL SIGNAL BYPASS V-6-395 switch in BYPASS position (Panel 11F).

(20001B/S7)

E5-2

Procedure EMG-3200.01B Support Proc-19 Rev.

9 Attachment F Page 1 of 2 SUPPORT PROCEDURE 19 FEEDWATER/CONDENSATE AND CRD SYSTEM OPERATION 1.0 PREREQUISITES Directed to maintain RPV level with the Feed, Condensate and CRD Systems by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Feedwater/Condensate 3.1.1 3.1.,2 Confirm one Condensate Pump and one Feedwater Pump operating.

Control RPV Water level using the following:

"* Feedwater Low Flow Valves

"* Heater Bank Outlet'Isolation Valves

"* Feedwater and Condensate Pumps 3.1.3 IF THEN 3.1.4 IF THEN RPV water level cannot be maintained below 160 in.,

close the Heater Bank Outlet Isolation Valve for the operating pump.

RPV water level reaches 170 in.,

trip the operating feedwater pump.

(20001B/S8)

CAUTION A large power excursion and substantial core damage could result from a rapid increase in injection into the RPV.

I E6-1

Procedure EMG-3200.01B Support Proc-19 Rev.

9 Attachment F Page 2 of 2 3.1.5 IF RPV water level reaches 170 in.,

THEN 3.1.6 IF THEN 3.2 CRD 3.2.1 3.2.2 3.2.3 AND RPV pressure is below 350 psig (shutoff head of the Condensate Pumps),

close all Heater Bank Outlet Isolation Valves.

RPV water level continues to increase, trip the operating Condensate Pumps.

IF Control Rods cannot be driven using CRD AND CRD bypass flow is desired for RPV water level control, THEN

1. Start all available CRD Pumps (Panel 4F).
2.

Open CRD Bypass Isolation Valve, V-15-237 (RB 23).

3.

Monitor flow on Flow Gage FI-225-2 (RB 23)

AND throttle open CRD Bypass Valve V-15-30 (RB 23) so as not to exceed 150 gpm flow for one or two pump operation.

IF RPV water level cannot be maintained less than 160 in.,

THEN

1. Throttle closed CRD Bypass Valve, V-15-30 (RB 23),

if opened

2.

Throttle closed CRD Flow Control Valve (Panel 4F)

IF RPV water level reaches 170 in.,

AND the CRD System is NOT required for rod insertion, THEN trip any operating CRD pump (Panel 4F).

(20001B/S8)

I E6-2

Procedure EMG-3200.01B Support Proc-20 Rev.

9 Attachment G Page 1 of 5 SUPPORT PROCEDURE 20 LOW PRESSURE INJECTION DURING AN ATWS 1.0 PREREQUISITES Injecting water with Low Pressure Systems has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 IF Core Spray activating signals are present, THEN override Core Spray initiation logic by depressing the OVERRIDE switches for all the sensors that are lit and depressing all ACTUATED switches, whether lit or unlit (Panel IF/2F).

2.2 The procedure for using Condensate Transfer for injection requires the use of an MB-I key and access to the Rx. Bldg.

3.0 PROCEDURE NOTE Overriding Core Spray initiation logic may be required.

3.1 IF Core Spray System 1 is to be used to inject Fire Water, THEN perform the following:

3.1.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 1 (Panel IF/2F).

3.1.2 Place Core Spray System 1 Main Pump control switches in PULL-TO-LOCK position (Panel IF/2F).

3.1.3 Close Tell-Tale Drain Valve, V-20-91 (RB 23 North or North Side RB outside).

3.1.4 Confirm running all Diesel Fire Pumps by placing their control switches in MAN position (Panel 13R).

3.1.5 Confirm open Core Spray System 1 Discharge Valve, V-20-12 (Panel IF/2F).

(20001B/S9)

E7-1

Procedure EMG-3200.01B Support Proc-20 Rev. 9 Attachment G Page 2 of 5 3.1.6 Confirm open either Core Spray System 1 Parallel Isolation Valve, V-20-15 or V-20-40 (Panel IF/2F).

3.1.7 Confirm closed Core Spray System 1 Test Flow Return Valve, V-20-27 (Panel IF/2F).

3.1.8 Close Core Spray System 1 Pump Suction Valves V-20-32 and V-20-3 (Panel IF/2F).

3.1.9 Slowly throttle open Fire Water Supply Valve, V-20-83 (RB 23 North or North Side RB outside) as required to maintain RPV Level.

3.2 IF Core Spray System 2 is to be used to inject Fire Water, THEN perform the following:

3.2.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 2 (Panel IF/2F).

3.2.2 Place Core Spray System 2 Main Pump control switches in PULL-TO-LOCK position (Panel IF/2F).

3.2..3 Close Tell-Tale Drain Valve, V-20-90 (RB 23 South or South Side RB outside).

3.2.4 Confirm running all Diesel Fire Pumps by placing their control switches in MAN position (Panel 13R).

3.2.5 Confirm open Core Spray System 2 Discharge Valve, V-20-18 (Panel IF/2F).

3.2.6 Confirm open either Core Spray System 2 Parallel Isolation Valve, V-20-21 or V-20-41 (Panel IF/2F).

3.2.7 Confirm closed Core Spray System 2 Test Flow Return Valve, V-20-26 (Panel IF/2F).

3.2.8 Close Core Spray System 2 Pump Suction Valves V-20-33 and V-20-4 (Panel IF/2F).

(20001B/S9)

E7-2

Procedure EMG-3200.01B Support Proc-20 Rev.

9 Attachment G Page 3 of 5 3.2.9 Slowly throttle open Fire Water Supply Valve, V-20-82 (RB 23 South or South Side RB outside) as required to maintain RPV Level.

3.3 IF Core Spray System 1 is to be used to inject Condensate

Transfer, THEN perform the following:

3.3.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 1 (Panel lF/2F).

3.3.2 Place Core Spray System 1 Main Pump control switches in PULL-TO-LOCK position (Panel lF/2F).

3.3.3 Unlock and open Regulator Bypass valves, V-11-110 and V-11-111 (RB 51 NW).

3.3.4 Confirm open Core Spray System 1 Discharge Valve, V-20-12 (Panel IF/2F).

3.3.5 Confirm open either Core Spray System 1 Parallel Isolation valve, V-20-15 or V-20-40 (Panel IF/2F).

3.3.6 Confirm closed Core Spray System 1 Test Flow Return Valve, V-20-27 (Panel lF/2F).

3.3.7 Start all available Condensate Transfer Pumps (Panel 5F/6F).

3.3.8 Close Core Spray System 1 Pump Suction Valves V-20-32 and V-20-3 (Panel IF/2F).

3.4 IF Core Spray System 2 is to be used to inject Condensate

Transfer, THEN perform the following:

3.4.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 2 (Panel IF/2F).

(20001B/S9)

E7-3

Procedure EMG-3200.01B Support Proc-20 Rev.

9 Attachment G Page 4 of 5 3.4.2 Place Core Spray System 2 Main Pump control switches in PULL-TO-LOCK position (Panel IF/2F).

3.4.3 Unlock and open Regulator Bypass valves, V-11-109 and V-11-108 (RB 75 S).

3.4.4 Confirm open Core Spray System 2 Discharge Valve, V-20-18 (Panel IF/2F).

3.4.5 Confirm open either Core Spray System 2 Parallel Isolation Valve, V-20-21 or V-20-41 (Panel IF/2F).

3.4.6 Confirm closed Core Spray System 2 Test Flow Return Valve, V-20-26 (Panel lF/2F).

3.4.7 Start all available Condensate Transfer Pumps (Panel-5F/6F).

3.4.8 Close Core Spray System 2 Pump Suction Valves V-20-33 and V-20-4 (Panel IF/2F).

3.5 CAUTION Core Spray suction strainer plugging may occur due to debris in the Primary Containment and result in a loss of Core Spray System Flow.

IF injection with the Core Spray Main Pump is directed, THEN inject with Core Spray as follows:

3.5.1 Confirm open Core Spray Pump Suction Valve for pump to be started (Panel IF/2F).

(20001B/S9)

E7-4

Procedure EMG-3200.01B Support Proc-20 Rev.

9 Attachment G Page 5 of 5 3.5.2 CAUTION Diesel Generator overload will result if a Core Spray Main Pump is started with a Diesel Generator load of greater than 2250 kw.

IF Bus 1C or 1D are being supplied by a Emergency Diesel Generator, THEN verify that adequate load margin is available so as NOT to exceed EDG load limit when starting Core Spray Main Pumps.

3.5.3 CAUTION NPSH problems will develop on all operating pumps if more than 4 Containment Spray/Core Spray Main pumps are operated at the same time.

IF 4 Containment Spray/Core Spray Main pumps are in operation, THEN secure Containment Spray pumps as necessary to run Core Spray pumps.

3.5.4 Start one Core Spray Main Pump (Panel lF/2F).

3.5.5 Confirm open the selected system Discharge Valve (V-20-12 or V-20-18).

(Panel lF/2F) 3.5.6 Open a Parallel Isolation Valve in the selected system, (V-20-15, V-20-40, V-20-21 or V-20-41).

(Panel IF/2F) 3.5.7 Start a Main Pump in the other Core Spray System, or open additional Parallel Isolation Valves as directed by the GSS/GOS.

(20001B/$9)

E7-5

Procedure EMG-3200.01B Support Proc-10 Rev.

9 Attachment H Page 1 of 1 SUPPORT PROCEDURE 10 STOPPING INJECTION FROM THE CORE SPRAY SYSTEM 1.0 PREREQUISITES Stopping Core Spray injection has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE When directed by the GOS/GSS, perform the following:

3.1 Depress the OVERRIDE switches for all sensors that are lit (Panel IF/2F).

3.2 Depress ALL ACTUATED switches whether lit or unlit (Panel IF/2F).

3.3 Confirm closed Core Spray Parallel Isolation Valves NOT required to be open to assure adequate core cooling.

3.4 Secure Core Spray Booster Pumps NOT required to assure adequate core cooling by placing their respective control switch in STOP (Panel IF/2F).

3.5 Secure Core Spray Main Pumps-NOT required to assure adequate core cooling by placing their respective control switch in STOP (Panel IF/2F).

3.6 Verify Core Spray KEEP FILL TROUBLE (B-3-d) alarm is NOT illuminated.

(20001B/S10)

E8-1

Procedure EMG-3200.01B Support Proc-ll Rev. 9 Attachment I Page 1 of 4 SUPPORT PROCEDURE 11 ALTERNATE PRESSURE CONTROL SYSTEMS ISOLATION CONDENSERS 1.0 PREREQUISITES RPV pressure control using the Isolation Condensers has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Procedure for Isolation Condenser A 3.1.1 Confirm Recirculation Pump A tripped.

IF Recirculation Pump A cannot be tripped from the Control Room, THEN trip the Recirculation Pump A Supply Breaker locally at 4160V Bus 1A.

3.1.2 CAUTION If RPV water level exceeds 180 in.,

initiation of an isolation condenser can cause water hammer to occur.

Verify RPV water level is below 160 in.

3.1.3 IF Isolation Condenser A has isolated on a high flow condition caused by Recirculation Pump operation, THEN restore the IC to operation as follows:

1. Open Steam Supply valves V-14-30 & V-14-31 by placing their control switches in the OPEN position (Panel IF/2F).
2.

Open DC Condensate Return valve V-14-34 by placing its control switch in the OPEN position (Panel IF/2F).

(20001B/Sll)

E9-1

Procedure EMG-3200.01B Support Proc-ll Rev.

9 Attachment I Page 2 of 4

3.

Open AC Condensate Return valve V-14-36 by placing its control switch in the OPEN position (Panel IF/2F).

4.

Reset the Isolation Condenser isolation signal using the Isolation Condenser Reset pushbutton (Panel 4F).

5.

Restore all Isolation Condenser A valve control switches to their AUTO position.

3.1.4 Confirm Open DC condensate return valve V-14-34 (Panel IF/2F).

3.1.5 Control RPV pressure in specified band by cycling V-14-34.

3.1.6 Make up to IC shell to maintain IC level between 4.8 ft.

and 7.7 ft.

by cycling Isolation Condenser A Make-Up Valve V-11-36 (Panel 5F/6F).

(20001B/Sll)

E9-2

Procedure EMG-3200.01B Support Proc-li Rev.

9 Attachment I Page 3 of 4 3.2 Procedure For Isolation Condenser B 3.2.1 Confirm Recirculation Pump E tripped.

IF Recirculation Pump E cannot be tripped from the Control Room, THEN trip the Recirculation Pump E Supply Breaker locally at 4160V Bus IA.

3.2.2 CAUTION If RPV water level exceeds 180 in.,

initiation of an isolation condenser can cause water hammer to occur.

Verify RPV water level is below 160 in.

3.2.3 IF Isolation Condenser B has isolated on a high flow condition caused by Recirculation Pump operation, THEN restore the IC to operation as follows:

1. Open Steam Supply valves V-14-32 & V-14-33 by placing their control switches in the OPEN position (Panel IF/2F).
2.

Open DC Condensate Return valve V-14-35 by placing its control switch in the OPEN position (Panel IF/2F).

3.

Open AC Condensate Return valve V-14-37 by placing its control switch in the OPEN position (Panel IF/2F).

4.

Reset the Isolation Condenser isolation signal using the Isolation Condenser Reset pushbutton (Panel 4F).

5.

Restore all Isolation Condenser B valve control switches to their AUTO position.

(20001B/S11)

E9--3

Procedure EMG-3200.01B Support Proc-ll Rev. 9 Attachment I Page 4 of 4 3.2.4 Confirm open DC condensate return valve V-14-35 (Panel lF/2F).

3.2.5 Control RPV pressure in specified band by cycling V-14-35.

3.2.6 Make up to IC shell to maintain IC level between 4.8 ft.

and 7.7 ft.

by cycling Isolation Condenser B Make-Up Valve V-11-34 (Panel 5F/6F).

(20001B/Sll)

E9-4

Procedure EMG-3200.01B Support Proc-12 Rev.

9 Attachment J Page 1 of 1 SUPPORT PROCEDURE 12 ALTERNATE PRESSURE CONTROL SYSTEMS EMRVs 1.0 PREREQUISITES RPV pressure control using the EMRVs has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Verify that Torus water level is above 90 in.

3.2 Place the selected EMRV control switch in the MAN position (Panel lF/2F).

3.3 Control reactor pressure in the specified band by opening the EMRVs in the following sequence:

NR108A NRI08D NR108B NR108C NR108E 3.4 Monitor Torus water temperature.

(20001B/S12)

E10-1

Procedure EMG-3200.01B Support Proc-13 Rev.

9 Attachment K Page 1 of 2 SUPPORT PROCEDURE 13 ALTERNATE PRESSURE CONTROL SYSTEMS CLEANUP IN RECIRCULATION MODE 1.0 PREREQUISITES 1.1 RPV pressure control using the Reactor Water Cleanup System in Recirculation Mode has been directed by the Emergency Operating Procedures.

1.2 No RWCU HELB exists.

2.0 PREPARATION When directed by GSS/GOS, perform the following:

2.1 Confirm that a Cleanup System line break does not exist (Alarms D-l-d/D-2-d).

2.2 Open the EOP BYPASS PLUGS panel in the rear of Panel 3F.

2.2.1 Remove the bypass plug from position BP2 and insert into position BPl.

2.2.2 Remove the bypass plug into position BP3.

2.2.3 Remove the bypass plug into position BP5.

2.2.4 Remove the bypass plug into position BP7.

2.3 Obtain a flat head screwdriver Tool Box in the Control Room.

from position BP4 and insert from position BP6 and insert from position BP8 and insert from the EOP 2.4 Open the front panel of Auxiliary Relay Panel ER-215-087 (A/B Battery Room).

2.4.1 Remove bypass plug 1 (upper left hand corner).

2.4.2 Remove bypass plug 2 (upper left hand corner).

(20001B/S13)

E11-1

Procedure EMG-3200.01B Support Proc-13 Rev.

9 Attachment K Page 2 of 2 3.0 PROCEDURE When directed by the GSS/GOS, perform the following 3.1 Bypass and isolate Cleanup Filters as follows:

3.1.1 Open V-16-83, Filter Bypass Valve (RB 75).

3.1.2 Close Filter Outlet Valve ND28A or ND28B (RB 75).

3.2 NOTE The remote valve operators to valves V-16-102, V-16-113, and V-16-114 have been disconnected.

Bypass and isolate the Cleanup Demineralizer:

3.2.1 Open Demineralizer Bypass Valve V-16-113 (RB 75 SW).

3.2.2 Close Demineralizer Outlet Valve V-16-114 (RB 75 SW).

3.2.3 Close Demineralizer Inlet Valve V-16-102 (RB 75 SW).

3.3 IF Cleanup System is not in service THEN Place the system in service in accordance with Procedure 303, Reactor Cleanup Demineralizer System.

3.4 Maximize RBCCW flow to the Non-Regenerative Heat Exchanger.

Maximum RBCCW flow allowed is 1750 gpm.

3.5 Maintain RPV pressure within desired band by throttling RBCCW flow to the NRHX.

(20001B/S13)

E11-2

Procedure EMG-3200.01B Support Proc-14 Rev. 9 Attachment L Page I of 2 SUPPORT PROCEDURE 14 ALTERNATE PRESSURE CONTROL SYSTEMS CLEANUP IN LETDOWN MODE 1.0 PREREQUISITES 1.1 RPV pressure control using the Reactor Water Cleanup System in Letdown Mode has been directed by theEmergency Operating.Procedures.

1.2 Boron Injection is not required.

1.3 No RWCU HELB exist.

2.0 PREPARATIONS None 3.0 PROCEDURE 3.1 Confirm that a Cleanup System line break does not exist (Alarms D-1-d/D-2-d).

3.2 IF Cleanup System is not in service THEN place the system in service in accordance with Procedure 303, Reactor Cleanup Demineralizer System.

3.3 Confirm closed the following valves:

"* Discharge to Radwaste V-16-57 (Panel 3F).

Discharge to Condenser V-16-60 (Panel 3F).

"* Discharge Flow Controller FCV-ND-22 (Panel 3F).

3.4 Open Discharge to Condenser Valve V-16-60 (Panel 3F).

3.5 Commence Letdown Flow to the main condenser by throttling open Discharge Flow Controller FCV-ND-22 (Panel 3F).

3.6 Carefully monitor Cleanup System Flow and make necessary adjustments with System Flow Controller FCN-ND-16 (Panel 3F) to maintain proper differential pressures across demineralizer and filter elements.

3.7 Maintain NRHX outlet temperature below 130'F by either reducing Letdown Flow using FCV-ND-22 (Panel 3F) or increasing RBCCW Flow through the NRHX using valve V-5-122 (RB 51 SE).

Maximum RBCCW Flow allowed is 1750 gpm.

3.8 Adjust letdown flow rate by throttling FCV-ND-22 to establish required cooldown rate or pressure band.

(20001B/S14)

E12-1

Procedure EMG-3200.01B Support Proc-14 Rev.

9 Attachment L Page 2 of 2 3.9 IF NRHX outlet temperature cannot be maintained less than 130OF AND the system trips THEN

1. Bypass and isolate the Cleanup Filter:
a.

Open V-16-83, Filter Bypass Valve (RB 75).

b.

Close Filter Outlet Valve ND28A or ND28B (RB 75).

2.

Bypass and isolate the Cleanup Demineralizer:

NOTE The remote valve operators to valves V-16-102, V-16-113, and V-16-114 have been disconnected.

a.

Open Demineralizer Bypass Valve V-16-113 (RB 75 SW).

b.

Close Demineralizer Outlet Valve V-16-114 (RB 75 SW).

c.

Close Demineralizer Inlet Valve V-16-102 (RB 75 SW).

3.

Contact I & C Department to inhibit the NRHX outlet high temperature as follows:

a.

At RK05 (75' B.lev.),

rotate the dial on TIS-IJ33 counterclockwise until the maximum trip setting is obtained.

4.

Return the Cleanup System to service in accordance with Procedure 303, Reactor Cleanup Demineralizer System.

5.

Perform Steps 3.2 through 3.5 to establish letdown flow.

6.

Adjust letdown flow rate by throttling FCV-ND-22 to establish required cooldown rate or pressure band.

(20001B/S14)

E12-2

Procedure EMG-3200.01B Support Proc-15 Rev. 9 Attachment M Page 1 of 2 SUPPORT PROCEDURE 15 ALTERNATE PRESSURE CONTROL SYSTEMS IC TUBE SIDE VENTS 1.0 PREREQUISITES RPV pressure control using the Isolation Condenser Tube Side Vents has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following in preparation for using the IC Tube Side Vents for RPV pressure control.

2.1 Verify the following:

1.

Isolation Condensers are not required to be isolated.

2.

Main Condenser is intact.

3.

Offsite radioactivity release rate is expected to remain below the release rate which requires an Unusual Event.

2.2 Confirm that the Isolation Condenser Vent Valve control switches for the Isolation Condenser to be used are in the normal mid-position (Panel 11F).

Isolation Condenser A V-14-5 V-14-20 Isolation Condenser B V-14-1 V-14-19 2.3 Open the EOP BYPASS PLUGS panel inside of Panel 1OXF.

2.3.1 Remove the bypass plug from position BP2 and insert it into position BPI.

2.3.2 Remove the bypass plug from position BP4 and insert it into position BP3.

(20001B/S15)

E13-1

Procedure EMG-3200.01B Support Proc-15 Rev.

9 Attachment M Page 2 of 2 3.0 PROCEDURE 3.1 Verify that RPV water level is below 180 in.

3.2 Confirm open the Isolation Condenser Steam Inlet Valves (IF/2F) for the Isolation Condensers to be used.

Isolation Condenser A V-14-30 V-14-31 Isolation Condenser B V-14-32 V-14-33 3.3 Open the Isolation Condenser Tube Side Vents (Panel 11F) for the Isolation Condensers to be used.

Isolation Condenser A V-14-5 V-14-20 Isolation Condenser B V-14-1 V-14-19 3.4 Control Reactor pressure in specified band by cycling the tube side vents designated in Step 3.3.

(20001B/S15)

E13-2

Procedure EMG-3200.01B Support Proc-21 Rev.

9 Attachment N Page 1 of 6 SUPPORT PROCEDURE 21 ALTERNATE INSERTION OF CONTROL RODS 1.0 PREREQUISITES Insertion of Control Rods utilizing alternate methods has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE When directed 3.1 Driving by the GSS/GOS, perform the following:

Control Rods 3.1.1 Start available CRD Pumps (Panel 4F).

3.1.2 Place Reactor Mode Switch in REFUEL (Panel 4F).

3.1.3 Place the ROD WORTH MININIZER keylock in BYPASS (Panel 4F).

3.1.4 Close CRD Drive Water Press Control Valve (NCI8)

(Panel 4F) to maximize CRD drive water differential pressure.

3.1.5 Close Charging Header Supply Valve V-15-52 (RB 23 SE).

3.1.6 Throttle closed bypass valve V-15-30 as required (RB 23 SE).

3.1.7 Rapidly insert control rods manually (Panel 4F).

(20001B/S16)

E14-1

Procedure EMG-3200.01B Support Proc-21 Rev.

9 Attachment N Page 2 of 6 3.2 Deeneraize Scram Solenoids 3.2.1 IF MSIVs are closed, THEN place both 100-amp Main RPS Breakers in OFF (Panel 6R/7R).

WHEN the control rods are no longer moving in, THEN confirm the 100 amp Main RPS Breakers in ON.

3.2.2 IF MSIVs are open, THEN place RPS Channel I and II Subchannel Test Keylocks IA, IB, IIA and IIB in TRIP position (Panel 6R/7R).

WHEN the control rods are no longer moving in, THEN confirm the RPS Channel I and II Subchannel Test Keylocks in NORMAL position (Panel 6R/7R).

3.3 Venting the Scram Air Header 3.3.1 Close Scram Air Header Isolation Valve V-6-175 (RB23SE).

3.3.2 Open Scram Air Header Drain Valve V-6-409 (RB23SE).

3.3.3 WHEN control rods are no longer moving in, THEN

1. Close Scram Air Header Drain Valve V-6-409.
2.

Open Scram Air Header Isolation Valve V-6-175.

(20001B/S16)

E14--2

Procedure EMG-3200.01B Support Proc-21 Rev.

9 Attachment N Page 3 of 6 3.4 Manual Scram 3.4.1 Place the ARI Normal/Bypass Switch in BYPASS position (Rear of Panel 8R).

3.4.2 Depress the ARI Manual Reset pushbutton (Panel 4F).

3.4.3 IF Defeating RPS logic trips is necessary prior to resetting the scram, THEN perform the following:

3.4.3.1 Obtain four (4) bypass plugs from the EOP Tool Box in the Control Room.

3.4.3.2 Open the EOP BYPASS PLUGS panel in the rear of Panel 6R.

1.

Insert a bypass plug into BP5.

2.

Insert a bypass plug into BP6.

3.4.3.3 Open the EOP BYPASS PLUGS panel in the rear of Panel 7R.

1.

Insert a bypass plug into BP5.

2.

Insert a bypass plug into BP6.

3.4.4 Confirm operating all available CRD Pumps (Panel 4F).

3.4.5 Reset the scram by depressing the Scram Reset Buttons (Panel 4F).

3.4.6 Confirm open SDV vent and drain valves (Panel 4F).

3.4.7 WHEN the SDV LEVEL HI-HI alarms (H-l-b and H-2-b)

clear, THEN manually scram the reactor by depressing the scram buttons (Panel 4F).

(20001B/S16)

E14-3

Procedure EMG-3200.01B Support Proc-21 Rev.

9 Attachment N Page 4 of 6 I~ r m

n r)

Individual Scram Test Switches 3.5.1 Place the ARI Normal/Bypass Switch in Bypass position (Rear of Panel 8R).

3.5.2 Depress the ARI Manual Reset pushbutton (Panel 4F).

3.5.3 IF Defeating RPS Logic trips is necessary prior to resetting the scram, THEN perform the following:

3.5.3.1 Obtain four (4) bypass plugs from the EOP Tool Box in the Control Room.

3.5.3.2 Open the EOP BYPASS PLUGS panel in the rear of Panel 6R.

1. Insert a
2.

Insert a 3.5.3.3 Open the EOP of Panel 7R.

1. Insert a
2.

Insert a 3.5.4 Confirm all available (Panel 4F).

bypass bypass BYPASS plug into BP5.

plug into BP6.

PLUGS panel in the rear bypass plug into BP5.

bypass plug into BP6.

CRD Pumps are operating 3.5.5 Reset the scram by depressing the Scram Reset Buttons (Panel 4F).

3.5.6 Confirm open SDV vent and drain valves (Panel 4F).

3.5.7 CAUTION While performing this procedure, potentially radioactive steam may be released and Reactor Building airborne contamination levels may increase.

Individually open the scram test switch on Panel 6XR for a control rod not inserted.

3.5.8 Close the scram test switch when the control rod stops moving.

3.5.9 Repeat Steps 3.5.7 and 3.5.8 as required.

(20001B/S16)

J..2 E14-4

Procedure EMG-3200.01B Support Proc-21 Rev.

9 Attachment N Page 5 of 6 3.6 Increasing CRD Cooling Water Differential Pressure 3.6.1 Start available CRD Pumps (Panel 4F).

3.6.2 Close Charging Header Supply Valve V-15-52 (RB 23 SE).

3.6.3 Increase CRD cooling water differential pressure.

3.6.4 Throttle closed bypass valve V-15-30 as required (RB 23 SE).

(20001B/S16)

E14-5

Procedure EMG-3200.01B Support Proc-21 Rev.

9 Attachment N Page 6 of 6 NOTE This method is to be used ONLY if all other insertion methods fail.

3.7 Venting Control Rod Drive Over Piston Volume NOTE If no CRD Pumps are available, this method may still be used provided Reactor pressure is greater than 600 psig.

CAUTION While performing this procedure, potentially radioactive steam may be released from the drain line effluent and Reactor Building airborne contamination levels may increase.

3.7.1 Start available CRD pumps (Panel 4F).

3.7.2 Close Cooling Water PCV isolation V-15-24 (RB23SE).

3.7.3 Close Exhaust Header root valve V-15-25 (RB23SE).

3.7.4 Close Stabilizer Unit Outlet valve V-15-40 (RB23SE).

3.7.'5 Confirm closed Cooling Water PCV bypass valve V-15-131 (RB 23 SE).

3.7.6 Open drain valve V-15-74 (RB 23 SE).

3.7.7 Place Reactor Mode Switch in REFUEL (Panel 4F).

3.7.8 Insert control rods manually from Panel 4F.

3.7.9 Monitor Reactor Building airborne radiation levels.

3.7.10 WHEN control rods' are no longer moving in THEN

1. Close V-15-74 (RB 23 SE).
2.

Open the following valves (RB 23 SE):

"* V-15-40

"* V-15-25

"* V-15-24 (20001B/S16)

E14-6

Procedure EMG-3200.01B Support Proc-22 Rev.

9 Page 1 of 1 SUPPORT PROCEDURE 22 INITIATING THE LIQUID POISON SYSTEM 1.0 PREREQUISITES Initiation of Standby Liquid Control System has been directed by the Emergency Operating Procedures.

2.0 PREPARATIONS None 3.0 PROCEDURE CAUTION Due to pressure fluctuations, Fuel Zone Level Indicator Channels "A" and "C" will not provide accurate indication of RPV water level if a Standby Liquid Control Pump is injecting into the RPV and should not be used.

3.1 Place the STANDBY LIQUID CONTROL keylock in the FIRE SYS 1 or FIRE SYS 2 position.

3.2 Verify the following:

1. -PUMP ON light for selected system illuminated (Panel 4F).
2.

SQUIBS light for selected system illuminated (Panel 4F).

3.

PUMP DISCH PRESS greater than Rx pressure (Panel 4F).

4.

FLOW ON Alarm annunciates (G-l-b).

5.

SQUIB VALVE OPEN Alarm annunciates (G-2-b).

3.3 IF the above expected indications do NOT occur, THEN -place the STANDBY LIQUID CONTROL Keylock in the opposite position to use the other system.

(20001B/S17)

E15-1

Procedure EMG-3200.01B Support Proc-23 Rev.

9 Attachment P Page I of 7 SUPPORT PROCEDURE 23 ALTERNATE BORON INJECTION WITH THE CLEANUP SYSTEM 1.0 PREREQUISITES 1.1 Injection of Boron via the Cleanup System has been directed by the Emergency Operating Procedures.

1.2 No RWCU HELB exists.

2.0 PREPARATION 2.1 Confirm that a Cleanup System line break does not exist.

(Alarms D-l-d/D-2-d)

NOTE After completing the steps in this section, Cleanup System Valves V-16-1, V-16-2, V-16-14 and V-16-61 will only operate from the control switches in the Control Room.

All automatic operation will be removed.

2.2 Open the EOP BYPASS PLUGS panel in the rear of Panel 3F.

2.2.1 Remove the bypass plug from position BP2 and insert into position BPI.

2.2.2 Remove the bypass plug into position BP3.

2.2.3 Remove the bypass plug into position BP5.

-1 2.2.4 Remove the bypass plug into position BP7.

2.3 Obtain a flat head screwdriver Control Room.

from position BP4 and insert from position BP6 and insert from position BP8 and insert from the EOP Tool Room in the 2.4 Open the front panel of Auxiliary Relay Panel ER-215-087 (A/B Battery Room).

2.4.1 Remove bypass plug.1 (upper left hand corner).

2.4.2 Remove bypass plug 2 (upper left hand corner).

(20001B/S18)

E16-1

Procedure EMG-3200.01B Support Proc-23 Rev.

9 Attachment P Page 2 of 7 3.0 PROCEDURE When directed by the GSS/GOS, perform the following:

3.1 IF no recirculation pump is

running, THEN
1. Confirm at least one recirculation loop suction and discharge valves open other than B loop.
2.

Close the B recirc loop discharge and discharge bypass valves.

3.2 Bypass and isolate the cleanup filters:

3.2.1 Open V-16-83, Filter Bypass Valve (RB 75).

3.2.2 Confirm close ND28A and ND28B, Filter Outlet Valve (RB 75).

3.3 Bypass and isolate the Cleanup Demineralizer:

3.3.1 Open V-16-113, Demineralizer Bypass Valve (RB 75 SW).

3.3.2 Close V-16-102, Demineralizer Inlet Valve (RB 75 SW).

3.3.3 Close V-16-114, Demineralizer Outlet Valve (RB 75 SW).

3.4 IF Cleanup System is not in service, THEN Place the system in service in accordance with Procedure 303, Reactor Cleanup Demineralizer System.

3.5 Use a backwashed/empty Cleanup Filter, or backwash a Cleanup Filter as follows:

3.5.1 Confirm Cleanup Filter Backwash Tank full.

(Pressure Gauge on RB 119' El. under tank should indicate -11.6 psig).

3.5.2 Verify Sludge Receiver Tank has sufficient volume to accommodate backwashing a filter.

Approximately a 2.5 ft.

level increase will occur per backwash.

(20001B/S18)

If Sludge Receiver Tank level is over nine (9) feet, the backwashing sequence can cause contamination of the plant ventilation system via six inch vent.

E16-2

Procedure EMG-3200.01B Support Proc-23 Rev.

9 Attachment P Page 3 of 7 3.5.3 NOTE Only one set of Filter Recycle Valves are capable of being open at any one time.

Place cleanup filter in recycle as follows:

1.

Open ND-31 A(B) Precoat/Recycle Outlet Valve.

2.

Start Precoat Pump to selected filter A(B).

3.

Open ND-30 A(B) Precoat/Recycle Inlet Valve.

3.5.4 Press ND-35 A(B) Backwash Programmer Control START button, until the A(B) programmer seals in.

It is sealed in when the green START and red UNIT IN BACKWASH lights stay on after the button is released.

3.5.5 Place PRECOAT PUMP CONTROL switch in OFF.

3.5.6 The following automatic sequence will occur:

1.

ND-27A(B),

Filter Inlet Valve, closes.

2.

ND-23A(B),

Air Inlet Valve, opens.

3.

ND-25A(B),

1 in.

Vent Valve (to RBEDT),

opens.

4.

ND-25A(B) closes.

5.

ND-30A(B),

Precoat (Recycle) Inlet Valve, and ND-31A(B),

Back to Precoat Valve, close.

6.

ND-26A(B),

Filter Sludge Tank Inlet Valve opens.

7.

ND-23A(B),

Air Inlet Valve, closes.

Procedure EMG-3200.01B Support Proc-23 Rev.

9 Attachment P Page 4 of 7 3.6 IF the Filter Aid Precoat Tank is being used to mix and add powdered Boric Acid and Borax, THEN continue in this procedure at Step 3.22.

3.7 IF the contents of the SLC Storage Tank is being injected using the Cleanup System, THEN continue in this procedure at Step 3.8.

3.8 Drain the Filter Aid Precoat Tank by opening V-16-117, Filter Aid Precoat Tank Drain Valve.

Close V-16-117 when the tank is drained.

3.9 Transfer the contents of the SLC Storage Tank to the Filter Aid Precoat Tank by performing Steps 3.9.1 through 3.9.4.

3.9.1 Connect a hose downstream of V-19-22, Pump A Suction Header Drain Valve, (RB95) and route the free end to the Filter Aid Precoat Tank.

Insert it through the hinged lid at the top and secure.

3.9.2 Unlock V-19-22, Pump A Suction Header Drain Valve.

3.9.3 Open V-19-22, Pump A Suction Header Drain Valve and fill the Filter Aid Precoat Tank to 90% full by gravity draining the SLC Storage Tank.

3.9.4 Close V-19-22, Pump A Suction Header Drain Valve.

3.10 Close V-16-108, Filter Recycle Valve.

3.11 Verify V-16-109, Cleanup Filter Return to Precoat Tank, is closed.

3.12 Open ND-30A(B),

Precoat/Recycle Inlet Valve.

3.13 Open V-16-107, Precoat Pump Suction Valve.

3.14 Place ND32, Precoat Pump Discharge Valve, control switch in the HOLD

.position.

3.15 Start the Precoat Pump in HAND position.

3.16 Open ND25A(B),

1 in.

Vent Valve (to RBEDT).

3.17 WHEN a steady stream of water is observed in the sightglass downstream of Valve ND-25A(B)

OR the Cleanup Filter Precoat Tank low level alarm annunciates, THEN

1. Stop the Precoat Pump.
2.

Close Valves ND-25A(B),

V-16-107, and ND-30A(B).

(20001B/S18)

E16-4

Procedure EMG-3200.01B Support Proc-23 Rev.

9 Attachment P Page 5 of 7 3.18 IF the Cleanup Filter Precoat Tank has reached the low level

limit, THEN repeat Steps 3.9.3 through 3.17.

3.19 NOTE During valving operations allow sufficient time for the (Red, Green) valve indication lights to completely change over.

Inject boron in accordance with Steps 3.19.1 through 3.19.4.

3.19.1 Open the ND27A(B),

Filter Inlet Valve, by placing its selector switch to the OPEN position.

3.19.2 NOTE When Valve ND28A(B) is placed in

AUTO, if the valve does not open or if it opens and then closes, a Cleanup Filter Isolation signal was actuated while the filter was in hold, and the programmer needs to be reset.

Instructions for resetting the programmer are contained in Procedure 303, Reactor Cleanup Demineralizer System.

Open ND28A(B),

Filter Outlet Valve, by placing its selector switch to the AUTO position.

3.19.3 Close V-16-83, Cleanup Filter Bypass Valve.

Allow approximately one (1) minute to ensure that the Filter Outlet Valve (ND28A(B) remains open.

3.19.4 Operate the Cleanup"System in this mode for five (5) minutes.

3.20 Bypass and isolate the Cleanup Filters.

3.20.1 Open V-16-83 3.20.2 Close ND27A(B) 3.20.3 Close ND28A(B) 3.21 Repeat Steps 3.9 through 3.20 until the contents of the SLC Storage Tank are injected into the reactor.

(20001B/S18)

E16-5

Procedure EMG-3200.01B Support Proc-23 Rev.

9 Attachment P Page 6 of 7 NOTE Steps 3.22 through 3.37 are used to mix and inject powdered boron using the Cleanup System and the Precoat Tank.

3.22 NOTE As required by Section 3.22, Boric Acid and Borax come in approximately 300 lb. barrels and are stored in the warehouse under Stock Numbers 001-512-1800-1 (Bin*2-Q068-E,J) and 001-512-2000-1 (Bin 2-Q064-E) respectively.

Although only six (6) barrels each are necessary to achieve a cold Boron shutdown weight of 273 lbs., plus a 25 percent conservatism, all available barrels (normally 10 each) should be transported to the Reactor Building 75 ft.

elevation.

Verify that the Precoat Tank is 80% full and if

not, fill with condensate transfer to a level of 80%.

3.23 Start the Precoat Tank Agitator and Precoat Tank Evacuator.

3.24 Add four barrels of Boric Acid and four barrels of Borax to the Filter Aid Precoat Tank and mix thoroughly.

3.25 Close V-16-108, Filter/Recycle Valve.

3.26 Verify V-16-109, Cleanup Filter Return to Precoat Tank Valve, is closed.

3.27 Open ND-30A(B),

Precoat/Recycle Inlet Valve.

3.28 Open V-16-107, Precoat Pump Suction Valve.

3.29 Place ND32, Precoat Pump Discharge Valve, control switch in the HOLD position.

3.30 Start the Precoat Pump in HAND position.

3.31 Open ND-25A(B),

1 in.

Vent Valve (to RBEDT).

3.32 WHEN a steady stream of water is observed in the sightglass downstream of valve ND-25A(B),

OR the Cleanup Filter Precoat Tank low level alarm annunciates, THEN

1. Place the Precoat Pump control switch to OFF.
2.

Close valves ND-25A(B),

V-16-107 and ND-30A(B).

(20001B/S18)

E16--6

3.33 IF THEN 3.34 Stop Procedure EMG-3200.01B Support Proc-23 Rev.

9 Attachment P Page 7 of 7 the Filter Aid Precoat Tank has reached the low level limit

1. Fill the Filter Aid Precoat Tank with condensate to a level of 80%.
2.

Repeat Steps 3.27 through 3.32.

the Precoat Tank Agitator and Dust Evacuator.

3.35 NOTE During valving operations, allow sufficient time for the (Red, Green) valve indication lights to completely change over.

Inject 3.35.1 3.25.2 boron in accordance with Steps 3.35.1 through 3.35.4.

Open ND-27A(B),

Filter Inlet Valve, by placing its selector switch to the OPEN position.

Open ND28A(B),

Filter Outlet Valve, by placing its selector switch to the AUTO position.

3.25.3 Close V-16-83, Cleanup System Filter Bypass Valve.

Allow approximately one (i) minute to ensure that the Filter Outlet Valve ND28A(B) remains open.

3.25.4 Operate the Cleanup System in this mode for five (5) minutes.

3.36 Bypass and isolate the Cleanup Filters by opening V-16-83 and closing ND27A(B) and ND28A(B).

3.37 Return to Step 3.5 as required to add additional boron.

(20001B/S18)

NOTE When Valve ND28A(B) is placed in

AUTO, if the valve does not open or if it opens and then closes, a Cleanup Filter Isolation signal was actuated while the filter was in hold, and the programmer needs to be reset.

To reset programmer refer to Procedure 303, Reactor Cleanup Demineralizer System.

El16-7

Procedure EMG-3200.01B Support Proc-24 Rev.

9 Attachment Q Page 1 of 8 SUPPORT PROCEDURE 24 ALTERNATE BORON INJECTION WITH THE FEED AND CONDENSATE SYSTEM 1.0 PREREQUISITES Injection of Boron via the Feed and Condensate System has been directed by the Emergency Operating Procedures.

2.0 PREPARATION NOTE The required Boric Acid and Borax come in approximately 300 lb.

barrels and are stored in the warehouse under Stock Numbers 001-512-1800-1 (Bin 2-Q068-E,J) and 001-512-2000-1 (Bin 2-Q064-E) respectively. Although only six (6) barrels each are necessary to achieve a cold shutdown Boron weight of 273 lbs. plus a 25 percent conservatism, all available barrels (normally 10 each) should be transported to the Turbine Operating Floor.

2.1 Transport all available barrels of Boric Acid and Borax from the warehouse to the Turbine Operating Floor.

2.2 Select a Condensate Demineralizer and transfer its resin to the Final Rinse & Storage Tank in accordance with Procedure 319, Condensate Demineralizer Resin Regeneration and Transfer System.

2.3 Confirm open Condensate Transfer Supply Valve V-11-14.

(Con Demin Area) 2.4 Confirm open FR & ST Bypass Valve V-2-788.

(Regen Room) 2.5 Confirm closed Resin Transfer Piping Cross-Connect Valve V-2-786 and FR & ST Inlet Valve V-2-787.

(Regen Room) 2.6 Check closed pressure breaker valves V-2-S-7 and V-2-S-9, by observing closed (green) indicating lights.

(20001B/S19)

E17-1

Procedure EMG-3200.01B Support Proc-24 Rev.

9 Attachment Q Page 2 of 8 3.0 PROCEDURE When directed by the GSS/GOS, perform the following:

3.1 Addition of Borax and Boric Acid into the Cation Tank NOTE Unless otherwise noted, all valve manipulations refer to selecting and operating a valve on the J.0. Backwash MANUAL OPERATION screen.

3.1.1 On the J.O. Backwash Main Menu, select the MANUAL OPERATION function.

3.1.2 Vent and drain the cation tank as follows:

3.1.2.1 Open vent valve V-2-C-4.

3.1.2.2 Open rinse outlet valve V-2-C-2.

3.1.3 WHEN the cation tank is vented and drained, THEN close rinse outlet valve V-2-C-2.

3.1.4 Open rinse inlet valve V-2-C-8 until the tank is approximately 30% full, then close V-2-C-8.

3.1.5 NOTE Equipment for performing this step is located on the EOP Locker on the Heater Bay Roof.

On the heater bay roof, perform the following:

3.1.5.1 Manually open pressure gauge isolation valve V-2-743 and verify that the cation tank is depressurized, then close V-2-743.

3.1.5.2 Confirm closed cation tank resin fill valve V-2-742.

(20001B/S19)

.E17-2

Procedure EMG-3200.01B Support Proc-24 Rev.

9 Attachment Q Page 3 of 8 3.1.5.3 Remove the flange above V-2-742.

Insert the funnel and hook up the water hose.

The funnel and hose are located on the east wall of the Turbine Building, directly in-line with the fill valve.

3.1.5.4 Open cation tank resin fill valve V-2-742.

3.1.5.5 Open Domestic Water Valve V-10-562 and add three drums of Boric Acid and three drums of Borax to the cation tank one scoop at a time.

Alternate scoops of boric acid and borax when filling cation tank.

3.1.5.6 WHEN all six drums have been added OR cation tank is 75% full, THEN close Domestic Water Valve V-10-562 and resin fill valve V-2-742.

3.1.6 IF cation tank level is not approximately 75% full, THEN open rinse inlet valve V-2-C-8 until cation tank level indicates approximately 75% full, then close V-2-C-8.

3.1.7 Open air inlet valve V-2-C-3, and air mix cation tank contents for 5-10 minutes, then close V-2-C-3.

3.1.8 Close vent valve V-2-C-4, and confirm closed vent valve V-2-C-14.

(20001B/S19)

NOTE Three drums of Borax and three drums of Boric Acid shall be added to the cation tank.

The time assumption for the addition of the six drums is approximately 45 minutes.

E17-3

Procedure EMG-3200.01B Support Proc-24 Rev. 9 Attachment Q Page 4 of 8 3.2 Transferring Borated Water from the Cation Tank to the Condensate Demineralizer Unit.

NOTE This instruction and subsequent valve management will apply to condensate demineralizer unit 1-1.

This same procedure is typical for the remaining demineralizer units.

3.2.1 Ensure the demineralizer to be used is isolated and drained by performing the following:

3.2.1.1 Verify the following valves are closed:

"* Condensate Inlet V-2-D-1I

"* Condensate Outlet V-2-D-12

"* Mixed Resin Inlet V-2-D-13

"* Mixed Resin Outlet V-2-D-14

"* Recycle Outlet V-2-D-15

"* Vent V-2-D-16.

3.2.1.2 Drain the unit by manually performing the following:

"* Confirm closed vent valve V-2-D-100.

"* Open header vent valve V-2-D-99.

"* Open recycle drain valves V-2-D-3 and V-2-D-8.

"* Slowly open demineralizer vent valve V-2-D-16 and recycle outlet valve V-2-D-15.

3.2.2 WHEN the demineralizer is drained, THEN manually close the following valves:

"* recycle drains V-2-D-3 and V-2-D-8

"* recycle outlet V-2-D-15 (20001B/S19)

E17-4

Procedure EMG-3200.01B Support Proc-24 Rev.

9 Attachment Q Page 5 of 8 3.2.3 Prepare to transfer borated water by opening the following valves:

3.2.3.1 Manually open demineralizer resin inlet valve V-2-D-13.

3.2.3.2 Open transfer valves V-2-T-2 and V-2-T-3.

3.2.4 Pressurize the cation tank by opening cation tank air inlet valve V-2-C-3.

3.2.5 Open cation tank resin outlet valve V-2-C-10 and transfer the borated water to the demineralizer unit.

3.2.6 After all borated water has been transferred to the demineralizer, as indicated by J.O. Backwash Panel or local sightglass, close the following valves:

3.2.6.1 Cation tank air inlet V-2-C-3.

3.2.6.2 Cation tank resin outlet V-2-C-10.

3.2.6.3 Transfer valves V-2-T-2 and V-2-T-3.

3.2.6.4 Demineralizer resin inlet V-2-D-13 (manually).

3.2.6.5 Demineralizer vent V-2-D-16 (manually).

3.2.6.6 Vent header isolation V-2-D-99 (manually).

3.3 "CAUTION The amount of time condensate flow is allowed to drop below 2400 gpm should be minimized to ensure adequate cooling flow is maintained to condensate system components.

To prevent loss of boron, isolate the following flow paths using Steps 3.3.1 through 3.3.5.

(20001B/S19)

E17-5

Procedure EMG-3200.01B Support Proc-24 Rev.

9 Attachment Q Page 6 of 8 3.3.1 NOTE A KAI0 Key is required for entry into the Condensate Transfer Building.

Isolate the demineralizer discharge to the Condensate Storage Tank by closing the following valves located in the Condensate Transfer Building.

"* V-2-42, Cond. Reject to CST Isolation Valve

"* V-2-14, Cond. Reject FRV Bypass Valve

"* V-2-88, Cond. Reject FRV Bypass Valve 3.3.2 Isolate the demineralizer discharge to the CRD WATER QUALITY LINE by shutting V-2-122, Flow Control Valve (V-2-124) Inlet Isolation Valve, in the Condenser Bay.

3.3.3 Isolate any reactor feedwater strings not required to maintain adequate core cooling by closing their Heater String Outlet Isolation Valves (V-2-10, V-2-11, V-2-12).

3.3.4 NOTE An MB-I Key is required to complete Step 3.3.4.

Isolate the reactor feed pump minimum flow lines by unlocking and closing V-2-230 (A),

231 (B) and 232 (C),

Minimum Flow Isolation Valves, to prevent boron loss.

3.3.5 Isolate Turbine Exhaust Hood Spray by shutting V-2-83, Condenser Hood Spray Isolation Valve.

(Turbine Bldg Mezzanine)

(20001B/S19)

E17-6

Procedure EMG-3200.01B Support Proc-24 Rev.

9 Attachment Q Page 7 of 8 3.4 NOTE All valve manipulations in this section must be done manually, as these valves are not operated on the J.O.

Backwash MANUAL OPERATION screen.

Place the demineralizer with Borated Water in service in accordance with the following:

3.4.1 Confirm at least one feed string is lined up for injection into RPV with its Condensate Pump running, feed pump running and heater string outlet valve open.

3.4.2 Confirm demineralizer inlet valve is cracked open.

3.4.3 Vent the demineralizer as follows:

1. Check closed auxiliary vent valve V-2-D-100 and open header vent valve V-2-D-99.
2.

Insure drain valve V-2-D-3, V-2-D-8 and other demineralizer units recycle valve are closed.

3.4.4 NOTE Minimize venting of Borated Water from the demineralizer.

CAUTION All air must be vented from the demineralizer before placing unit in service.

Verify proper fill and venting of the demineralizer by cracking open the unit vent valve V-2-D-16 until water runs through the vent sight glass.

3.4.5 Close the unit's vent valve V-2-D-16 and V-2-D-99 when the demineralizer is filled and vented.

3.4.6 Open outlet valve V-2-D-12 to put Condensate Demineralizer in service.

(20001B/S19)

E17-7

Procedure EMG-3200.01B Support Proc-24 Rev.

9 Attachment Q Page 8 of 8 3.5 IF THEN 3.6 IF THEN 3.7 Return additional Boron is

required, repeat Steps 3.1 through 3.4 directed by the GSS, return system to normal per Procedure 319.

to the J.O. Backwash Main Menu by pressing the HOME key.

(20001B/S19)

E17-8

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.02 NUCLEAR Title Revision No.

PRIMARY CONTAINMENT CONTROL 15 Applicability/Scope" Responsible Office PLANT ENGINEERING EMERGENCY OPERATING PROCEDURE FOR OYSTER CREEK 2200 This document is within QA plan scope X Yes No Effective Date Safety Reviews Required X Yes No (04/25/00) 05/05/00 Prior Revision 14 incorporated the This Revision 15 incorporates the following Temporary Changes:

following Temporary Changes:

N/A N/A List of Pages (all pages rev'd to Rev.

15) 1.0 to 4.0 El-1 E2-1 to E2-2 E3-1 to E3-4 E4-1 to E4-2 E5-1 to E5-2 E6-1 to E6-3 E7-1 to E7-2 E8-1 to E8-3 E9-1 to E9-2 El0-1 to El0-2 El1-1 to Eli-2 E12-1 to E12-2 E13-1 to E13-2 E14-1 to E14-6 E15-1 to E15-4 E16-1 to E16-2 E17-1 E18-1 to E18-2 E19-1 to E19-4 E20-1 to E20-3 E21-1 to E21-4 E22-1 to E22-4..

E23-1 to E23-2 E24-1 to E24-3 E25-1 to E25-2 OYSTER CREEK CONTROLLED DISTRIBUTION DOCUMENT SERIAL NUMBER IRMC Signature, Concurring Organization Element Date Originator EOP COORDINATOR Concurred By EOP COMMITTEE/0 DIRECTOR EQUIPMENT RELIABILITY

ý d1 Aproe

-___PLANT OPERATIONS DIRECTOR A- %s-,c Approved VICE P By VICE PRESIDENT & DIRECTOR, OC

-+

(320002) 1.0

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.02 NUCLEAR Title Revision No.

PRIMARY CONTAINMENT CONTROL 15 1.0 PURPOSE The purpose of the Primary Containment Control Procedure is to:

"* Protect equipment in the Primary Containment

"* Maintain Primary Containment integrity

2.0 REFERENCES

2.1 Procedures 107.4, EOP Program Control 310 312 2.2 Drawings BR 2006, Flow Diagram Closed Cooling Water System BR 2011, Shts 1 & 2, Flow Diagram -

H&V Reactor Bldg BR 3017, 460 VAC MCC Elem Diagram Sht 4 GE 112C2654, Sht 3, Panel 2R Connection Diagram GE 157B6350, Shts 117 & 118, RBCCW Valve Elem Diagram GE 237E566, Shts la, lb, 2 & 6, Rx Protection System Elem Diagram GE 706E841, Vent & Effluent Rad Monitor Elem Diagram GU 3D-822-17-1002, Elem Diagram -

Standby Gas Treatment System GU 3D-822-21-1000, Flow Diagram -

Standby Gas Treatment System NU 506036003, Shts 1 -

3, Core Spray/RBCCW Drywell Isolation Elem Diagram SN 13432.19-1, Flow Diagram -

N2 Purge and Makeup Sys SN 15361.03-EC-23, Area Rad Monitoring Elem Diagram 2.3 2000-GLN-3200.01, OC Plant Specific Technical Guidelines 2.4 2000-STD-1218.04, EOP Writer's Guide (320002) 2.0

(

0OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.02 NUCLEAR Title Revision No.

PRIMARY CONTAINMENT CONTROL 15 3.0 PRECAUTIONS AND LIMITATIONS 3.1 This procedure gives guidance to the operator for bypassing isolation signals and automatic scrams which is a departure from the Oyster Creek Technical Specifications.

It is permissible to take actions which depart from the plant's Technical Specifications during emergency conditions as authorized by 10 CFR 50.54 (x).

4.0 ATTACHMENTS 4.1 Attachment A -

Primary Containment Control EOP Flowchart DWG: GU 3E-200-08-010 sh 1 4.2 Attachment B - Support Procedure 25, Initiation of the Containment Spray System in the Torus Cooling Mode 4.3 Attachment C - Support Procedure 26, Determining Bulk Drywell Temperature 4.4 Attachment D - Support Procedure 27, Maximizing Drywell Cooling 4.5 Attachment E - Support Procedure 28, Level Instrumentation Availability 4.6 Attachment F -

Support Procedure 29, Initiation of the Containment Spray System for Drywell Sprays 4.7 Attachment G -

Support Procedure 30, Confirmation of Primary Containment Isolation 4.8 Attachment H -

Support Procedure 31, Venting Primary Containment to maintain Pressure Below 3.0 psig 4.9 Attachment I -

Support Procedure 32, Venting the Torus for Primary Containment High Pressure 4.10 Attachment J Support Procedure 33, Venting the Drywell for Primary Containment High Pressure 4.11 Attachment K -

Support Procedure 34, Venting the Drywell through the Purge System for Primary Containment High Pressure 4.12 Attachment L -

Support Procedure 35, Venting the Torus Through the Hardened Vent 4.13 Attachment M -

Support Procedure 36, Venting the Drywell Through the Hardened Vent (320002) 3.0

4.14 Attachment N - Support Procedure Spray System 37, Makeup to the Torus via Core 4.15 4.16 4.17 4.18 4.19 4.20 4.21 4.22 4.23 4.24 4.25 Attachment Y -

Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment Attachment Support Control Procedure 48, Venting the Drywell for Hydrogen (320002)

(

0*OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.02 NUCLEAR Title Revision No.

PRIMARY CONTAINMENT CONTROL 15 Support Procedure 38, Determining Primary Containment Water Level Support Procedure 39, Placing the H2/02 Monitoring System In Service Support Procedure 40, Isolation of the Primary Containment Vent and Purge Valves Support Procedure 41, Venting the Torus for Hydrogen Control Support Procedure 42, Purging the Drywell for Hydrogen Control Support Procedure 43, Venting the Drywell for Hydrogen Control (Level Below 461 in)

Support Procedure 44, Venting the Drywell through the Rx Building Supply Fans for Hydrogen Control (Level Above 461 in)

Support Procedure 45, Purging the Torus for Hydrogen.

Control

- Support Procedure 46, Venting the Torus for Hydrogen Control

- Support Procedure 47, Venting the Drywell for Hydrogen Control (Level Below 461 in) 4.0

(

1"OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.02 NUCLEAR Title Revision No.

PRIMARY CONTAINMENT CONTROL 15 ATTACHMENT A Attachment A to EMG-3200.02, Primary Containment Control, is the Primary Containment Control EOP Flowchart, DWG:

GU 3E-200-08-010 Sht 1, Rev. 3 (320002/3)

E1-1

Procedure EMG-3200.02 Support Proc.

25 Rev.

15 Attachment B Page 1 of 2 SUPPORT PROCEDURE 25 INITIATION OF THE CONTAINMENT SPRAY SYSTEM IN THE TORUS COOLING MODE 1.0 PREREQUISITES Initiation of the Containment Spray System in the Torus Cooling Mode has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE CAUTION Containment Spray suction strainer plugging may occur due to debris in the Primary Containment and result in a loss of Containment Spray System Flow.

3.1 CAUTION Diesel Generator overload will result if a Containment Spray Pump and ESW pump are started with a Diesel Generator load of greater than 2150 KW.

IF Bus 1C or 1D are being supplied by an Emergency Diesel Generator, THEN verify that adequate load margin is available so as NOT to exceed EDG load limit when starting Containment Spray and ESW Pumps.

3.2 CAUTION NPSH problems will develop on all operating pumps if more than 4 Containment Spray/Core Spray Main pumps are operated at the same time.

IF 4 Containment Spray/Core Spray Main pumps are in operation, THEN do not start additional Containment Spray pumps until Core Spray Main pumps can be secured.

(320002/4)

E2-1

Procedure EMG-3200.02 Support Proc.

25 Rev.

15 Attachment B Page 2 of 2 3.3 Start a Containment Spray Pump as follows:

3.3.1 Select the Containment Spray System to be used by confirming either SYSTEM 1 MODE SELECT or SYSTEM 2 MODE SELECT switch in TORUS CLG position.

3.3.2 Select a Containment Spray Pump to be started.

3.3.3 Place and hold the System Pump Start Permissive Keylock for the selected pump in the appropriate position (Panel IF/2F).

3.3.4 Start the selected Containment Spray Pump using its control switch (Panel IF/2F).

3.4 Start an associated ESW Pump using its control switch (Panel IF/2F).

3.5 Monitor system parameters for expected performance.

3.6 Start additional Containment Spray and ESW Pumps as directed by the GSS/GOS in accordance with Steps 3.1 thru 3.5.

3.7 IF all Containment Spray pumps that are running are not required for Torus cooling, THEN inform the GSS/GOS and secure the Containment Spray pumps that are not required for Torus cooling.

(320002/4)

E2-2

Procedure EMG-3200.02 Support Proc.

26 Rev.

15 Attachment C Page 1 of 4 SUPPORT PROCEDURE 26 DETERMINING BULK DRYWELL TEMPERATURE 1.0 PREREQUISITES Determination of Bulk Drywell Temperature has been directed by the Emergency Operating Procedures.

2.0 PREPARATIONS None 3.0 PROCEDURE IF computer point DWTEMP is unavailable or questionable

("Q" for point health),

THEN determine drywell bulk temperature by using the appropriate calculation and the following recorders:

"* Recorder IA55 (Panel 8R)

"* Recorder TR-100A (RB 51' Elev.)

3.1 Complete Calculation on Attachment DWT-I.I.

3.2 Calculate Bulk Drywell Temperature (TB) using values from Attachment DWT-I.1.

TB = 0.503

+ 0.382

+

(T Avg IA)

(T Avg IB) 0.076

+ 0.039 (T Avg II)

(T Avg III)

TB =

3.2.1 IF temperature recorder IA55 is not available, THEN calculate bulk drywell temperature using the following equation:

TB = 0.885

+ 0.076 (T Avg IB)

(T Avg II)

+ 0.039 (T Avg III)

(320002/5)

E3 -1

Procedure EMG-3200.02 Support Proc. 26 Rev.

15 Attachment C Page 2 of 4 3.2.2 IF THEN 3.2.3 IF THEN 3.2.4 IF any T/C 105 indicates >395°F, check T/C 107 reading for confirmation of high temperature conditions.

two out of three T/C 105's indicate 315°F < T > 325 0 F, evaluate drywell cooling using Procedure OPS-3024.09, Drywell Cooling System - Diagnostic and Restoration Actions.

two out of three T/C 105's indicate T > 3250 F, THEN initiate a plant shutdown in accordance with Procedure 203.1, Plant Shutdown to Hot Standby.

3.3 IF bulk drywell temperature cannot be determined using the plant

computer, AND an operator is not immediately available to monitor Drywell temperature at 51' elev. OR Temperature Recorder TR-100A is not available, THEN determine bulk drywell temperature by averaging the inlet temperatures of the operating Drywell Recirc. Fans.

(Points 11, 12, 13, 14, and 15 from recorder IA55 on Panel 8R).

3.3.1 IF less than three Drywell Recirc Fans are running, THEN calculate bulk drywell temperature by averaging the temperatures of the GEMAC narrow and wide range reference legs (Points 40, 41, and 42 from recorder IA55 on Panel 8R).

(320002/5)

NOTE Thermocouple readings > 395*F must be read using Plant Computer Points or by an instrument technician using instrumentation for Type T thermocouples.

E3 -2

Procedure EMG-3200.02 Support Proc.

26 Rev.

15 Attachment C Page 3 of 4 ATTACHMENT DWT-l.I Temperature readings from the following thermocouples can be obtained locally from the recorder or from the plant computer by identified ID points.

NOTE Thermocouple readings >3950 F must be read using Plant Computer Points or by an instrument technician using instrumentation for Type T thermocouples.

1. IF one thermocouple reading is not available (i.e.;

downscale or upscale)

THEN remove it from the T Avg calculation and decrease the denominator by one number.

2.

Calculate T Avg IA by completing the following:

a From Recorder IA55 (Panel 8R) or the Plant Computer, record the following data:

Recorder Point COMP ID PT Value (°F)

PT.35 = TE-100A,El.

33' Recirc Pump Motor Inlet Air "A" PT.36 = TE-100B,El.

33' Recirc Pump Motor Inlet Air "B" PT.37 = TE-100C,El.

33' Recirc Pump Motor Inlet Air "C" PT.38 = TE-100D,El.

33' Recirc Pump Motor Inlet Air "D" PT.39 = TE-100E,.El.

33' Recirc Pump Motor Inlet Air "E"

  • Calculate T Avg IA T Avg IA

= PT.35 + PT.36 + PT.37 + PT.38 + PT.39 5

3.

Calculate T Avg IB by completing the' following:

  • From Recorder TR-100A (RB 51' following data:

Recorder Point PT.I

= TE-103A,El.

50' Safety Valve PT.2

= TE-103B,El.

50' Safety Valve PT.3

= TE-103C,El.

50' Safety Valve PT.4

= TE-103D,El.

50' Safety Valve PT.5

= TE-103E,El.

50' Safety Valve Elev.) or the Plant Computer, record the Area Area Area Area Area COMP ID PT

'TEI03A'

'TEI03B'

'TEl03C'

'TE103D'

'TEl03E' Value (OF)

  • Calculate T Avg IB T Avg IB

= PT.I + PT.2 + PT.3

+ PT.4 + PT.5 5

(320002/5)

'TEI00A'

'TEI0OB'

'TEl0OC'

'TEI00D'

'TEI00E' OF E3-3

Procedure EMG-3200.02 Support Proc. 26 Rev.

15 Attachment C Page 4 of 4

4.

Calculate T Avg II by completing the following:

  • From Recorder TR-100A (RB 51' Elev.) or the Plant Computer, record the following data:

Recorder Point COMP ID PT Value (°F)

PT.6

= TE-104A,El.

93' Rx Vessel Bellows Seal Area

'TEI04A' PT.7

= TE-104B,El.

93' Rx Vessel Bellows Seal Area

'TE104B' PT.8

= TE-104C,El.

93' Rx Vessel Bellows Seal Area

'TEI04C' PT.9

= TE-104D,El.

93' Rx Vessel Bellows Seal Area

'TE104D' PT.10 = TE-104E,El.

93' Rx Vessel Bellows Seal Area

'TEI04E'

  • Calculate T Avg II T Avg II

= PT.6 + PT.7 + PT.8 + PT.9 + PT.10 5

=O°F

5.

Calculate T Avg III by completing the following:

  • From Recorder TR-100A (RB 51' Elev.) or the Plant Computer, record the following data:

Recorder Point COMP ID PT Value ('F)

PT.II = TE-105A,El.

95' Rx Head Flange Area

'TEI05A' PT.12 = TE-105B,El.

95' Rx Head Flange Area

'TEI05B' PT.13 = TE-105C,El.

95' Rx Head Flange Area

'TEl05C' Calculate T Avg III T Avg III

= PT.II + PT.12 + PT.13 3

OF (320002/5)

E3-4

Procedure EMG-3200.02 Support Proc.

27 Rev.

15 Attachment D Page I of 2 SUPPORT PROCEDURE 27 MAXIMIZING DRYWELL COOLING 1.0 PREREQUISITES The operation of all available drywell coolers has been directed by the Emergency Operating Procedures AND the RBCCW System is NOT isolated due to a LOCA or MSLB in the Drywell.

2.0 PREPARATION 2.1 NOTE After completing the following steps, valves V-5-147, V-5-166 and V-5-167 will only operate from the Control Room.

All automatic operation is removed.

In the rear of Panel 2R, open the EOP BYPASS PLUGS panel.

2.1.1 Remove the bypass plug from position BPI.

2.1.2 Remove the bypass plug from position BP2.

3.0 PROCEDURE 3.1 CAUTION Reinitiating RBCCW flow to the Drywell following a LOCA or MSLB in the Drywell may cause a water hammer to occur and subsequent piping failure.

Verify that the RBCCW System is not isolated due to high Drywell pressure/low RPV water level conditions.

3.2 IF the RBCCW System is isolated due to high Drywell pressure/low RPV water level, THEN inform the Licensed Operations Supervisor and do not attempt to reinitiate the RBCCW System flow to the Drywell.

3.3 Confirm open RBCCW Isolation Valves (Panel IF/2F)

"* V-5-147

"* V-5-166

"* V-5-167

"* V-5-148 (320002/6)

E4-1

Procedure EMG-3200.02 Support Proc.

27 Rev.

15 Attachment D Page 2 of 2 3.4 Start all available DW RECIRC FANS by placing their respective control switches in ON (Panel 11R).

3.5 Place the ISOL SIGNAL BYPASS V-6-395 switch in BYPASS position (Panel 11F).

3.6

[1 11 Operate DW RECIRC FANS (Panel 11R) as required to control Drywell temperature.

(320002/6)

CAUTION A rapid decrease in Drywell temperature could cause a corresponding drop in Drywell Pressure and possible deinertion.

E4-2

Procedure EMG-3200.02 Support Proc.

28 Rev.

15 Attachment E Page 1 of 2 SUPPORT PROCEDURE 28 LEVEL INSTRUMENTATION AVAILABILITY 1.0 PREREQUISITES The evaluation of RPV Water Level Instruments has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE An RPV water level instrument may be used to determine RPV water level only when all the following conditions are satisfied for that instrument.

3.1 Verify that the temperatures of the following instrument reference leg vertical runs as read on recorder TR-IA55 on Panel 8R are below RPV saturation temperature.

Level Instrument Temy Instrument No.

Recorder Point Temperature NR GEMAC A (LT-IDI3A)

TE-130-450 40 NR GEMAC B (LT-IDI3B)

TE-130-451 41 WR GEMAC (LT-IA12)

TE-130-452 42 YARWAY A (LT-RE05/19A)

TE-130-453 43 YARWAY B (LT-REO5/19B)

TE-130-454 44 (320002/7)

E5-1

Procedure EMG-3200.02 Support Proc. 28 Rev.

15 Attachment E Page 2 of 2 550

=",ooI i

I I

I Z

w 2I4 400 z

3504 0i U)

Er300 '

200 0

100 200 300 400 500 600 700 8W0 9W0 1000 1100 RPV PRESSURE (psio, RPV Saturation Temperature 3.2 For each instrument below, the instrument reads above the minimum indicated level or the reference leg temperature is below the maximum run temperature.

(320002/7)

GEMAC NARROW RANGE Indicated level above 104 in.

(90 -

180 in.)

OR Ref. leg temperature below 420'F YARWAY Indicated level above 100 in.

(85 185 in.)

OR Ref. leg temperature below 460'F GEMAC WIDE RANGE Indicated level is greater than the value (100 -

700 in.)

listed for the reference leg temperature.

Ref Leg Temp.

Indicated Level 40 -

200'F Above 100 in.

200 -

300OF Above 120 in.

300 -

400°F Above 140 in.

400 -

500OF Above 170 in.

500 -

550°F Above 190 in.

E5-2

Procedure EMG-3200.02 Support Proc.

29 Rev.

15 Attachment F Page 1 of 3 SUPPORT PROCEDURE 29 INITIATION OF THE CONTAINMENT SPRAY SYSTEM FOR DRYWELL SPRAYS 1.0 PREREQUISITES Manual initiation of Drywell Sprays has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 Select the Containment Spray System to be used by confirming either SYSTEM 1 MODE SELECT or SYSTEM 2 MODE SELECT switch in DW SPRAY position (Panel IF/2F).

2.2 Verify that the system TORUS CLG DISCHARGE valve closes and DW SPRAY DISCHARGE valve opens (Panel IF/2F).

3.0 PROCEDURE CAUTION Containment Spray suction strainer plugging may occur due to debris in the Primary Containment and result in a loss of Containment Spray System Flow.

3.1 CAUTION Diesel Generator overload will result if a Containment Spray pump and ESW pump are started with a Diesel Generator load of greater than 2160 KW.

IF Bus IC or 1D are being supplied by an Emergency Diesel Generator, THEN verify that adequate load margin is available so as NOT to exceed EDG load limit when starting Containment Spray and ESW pumps.

(320002/8)

E6-1

Procedure EMG-3200.02 Support Proc.

29 Rev. 15 Attachment F Page 2 of 3 3.2 WHEN directed to initiate Drywell sprays, THEN complete the following:

1. Confirm the Reactor Recirculation Pumps tripped (Panel 3F).
2.

Confirm the Drywell Recirc Fans tripped (Panel 1IR).

3.3 CAUTION NPSH problems will develop on all operating pumps if more than 4 Containment Spray/Core Spray Main pumps are operated at the same time.

IF 4 Containment Spray/Core Spray Main pumps are in operation, THEN do not start additional Containment Spray pumps until Core Spray Main pumps can be secured.

3.4 Start a Containment Spray Pump as follows:

3.4.1 Select a Containment Spray Pump to be started.

3.4.2 Place and hold the System Pump Start Permissive Keylock for the selected pump in the appropriate position (Panel IF/2F).

3.4.3 Start the selected Containment Spray Pump using its control switch (Panel IF/2F).

3.5 Start an associated ESW Pump using its control switch (Panel IF/2F).

3.6 Monitor System parameters for expected performance.

3.7 NOTE Valves V-5-147, 166 and 167 do not seal in when the control switch is taken to close.

The control switch must be held in close until the valve indicates closed.

Confirm the following RBCCW Isolation valves closed (Panel IF/2F):

"* V-5-147

"* V-5-148

"* V-5-166

"* V-5-167 (320002/8)

E6-2

Procedure EMG-3200.02 Support Proc. 29 Rev.

15 Attachment F Page 3 of 3 3.8 CAUTION Diesel generator overload will result if a containment spray pump and ESW pump are started with a diesel generator load of greater than 2160 KW.

Start additional Containment Spray and ESW Pumps in accordance with Steps 3.3 through 3.6 as directed by the GSS/GOS.

3.9 Maintain primary containment pressure in a band of 4 to 12 psig unless otherwise directed by the GSS/GOS as follows:

3.9.1 Secure drywell sprays when drywell pressure drops to 4 psig.

3.9.2 WHEN Torus pressure increases to 12 psig, THEN initiate drywell sprays in accordance with Steps 3.3 through 3.6.

3.10 IF any Core Spray Booster pump is running AND Torus OR Drywell pressure drops to 2 psig, THEN confirm termination of Drywell Sprays.

3.11 IF no Core Spray Booster pump is running AND Torus OR Drywell pressure drops below 1 psig, THEN confirm termination of Drywell Sprays.

3.12 IF Containment Spray Pumps fail to trip, THEN place the respective system MODE SELECT switch in TORUS CLG position.

(320002/8)

E6-3

Procedure EMG-3200.02 Support Proc.

30 Rev.

15 Attachment G Page 1 of 2 SUPPORT PROCEDURE 30 CONFIRMATION OF PRIMARY CONTAINMENT ISOLATION 1.0 PREREQUISITES Confirmation of Primary Containment isolation has-been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Confirm closed the following valves that are not required to be open by the Emergency Operating Procedures:

System Valve No.

DW Vent/Purge V-27-1 (Panel 11F)

V-27-2 V-27-3 V-27-4 Torus Vent V-28-17 (Panel 11F)

V-28-18 Torus 2" Vent Bypass V-28-47 (Panel 11F)

DWEDT V-22-1 (Panel 11F)

V-22-2 DW Floor Sump V-22-28 (Panel 11F)

V-22-29 Torus/Rx Bldg.

V-26-16 (Panel 11F)

Vacuum Breakers V-26-18 TIP Valves Common Ind.

(Panel 11F)

(320002/9)

E7-1

DW 2" Vent Bypass N2 Purge N2 Makeup V-23-21 V-23-22 V-23-13 V-23-14 V-23-15 V-23-16 V-23-17 V-23-18 V-23-19 V-23-20 (Panel 12XR)

(Panel 12XR)

(Panel 12XR)

(320002/9)

Procedure EMG-3200.02 Support Proc.

30 Rev.

15 Attachment G Page 2 of 2 E7-2

Procedure EMG-3200.02 Support Proc.

31 Rev.

15 Attachment H Page 1 of 3 SUPPORT PROCEDURE 31 VENTING THE PRIMARY CONTAINMENT TO MAINTAIN PRESSURE BELOW 3.0 PSIG 1.0 PREREQUISITES Venting of the Primary Containment has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 IF the GSS/GOS directs usage of SGTS for venting, THEN perform the following:

1. Select a SGTS Train for operation by placing the STANDBY GAS SELECT switch in position SYSTEM 1 or SYSTEM 2.
2.

Place the fan control switch for the train selected in the HAND position.

3.

Close the SGTS CROSSTIE V-28-48 (Panel 1IR)

4.

Secure operating Reactor Building Supply Fans by placing the respective control switches in OFF position (Panel 11R).

5.

Immediately secure Exhaust Fan EF 1-5 (or EF 1-6) by placing control switch in STOP position (Panel 11R).

6.

Close V-28-21 and V-28-22 by placing the EXH VALVES TO MAIN EXHAUST control switch in CLOSE position.

7.

Close V-28-42 and V-28-43 by placing the MAIN SUPPLY HEADER VALVES TO DW control switch in CLOSE position.

8.

Open Torus Vent Valve V-28-18 (Panel 11F).

(320002/10)

E8-1

Procedure EMG-3200.02 Support Proc.

31 Rev.

15 Attachment H Page 2 of 3

9.

Cycle V-28-47 to maintain Drywell pressure below 3.0 psig (Panel 11F).

10.

IF the Torus cannot be vented, THEN perform the following:

a.

Inform the GSSIGOS.

b.

Open the Drywell vent valve V-23-21 (Panel 12XR).

c.

Cycle Drywell vent valve and V-23-22 (Panel 12XR) to maintain Drywell pressure below 3.0 psig.

11.

WHEN the primary containment is being vented through

SGTS, THEN perform the following:
a.

Notify Chemistry that Rx Bldg. ventilation has been secured so that they can shift the stack RAGEMS DEFAULT SYSTEM CONTROL switch to DEFEAT.

b.

Confirm that the final SGTS lineup has the preferred system in operation, and V-28-48, SGTS CROSSTIE DAMPER is closed.

c.

Confirm running Turbine Building Exhaust Fan EF 1-7 or one Radwaste Bldg. Exhaust Fan, EF 1-16 or EF 1-17, to maintain a minimum stack flowrate/exit velocity of 50 fpm.

(320002/10)

E8-2

Procedure EMG-3200.02 Support Proc.

31 Rev.

15 Attachment H Page 3 of 3 3.2 IF the GSS/GOS directs usage of Rx. Bldg. ventilation for

venting, THEN perform the following:
1. Open Torus Vent valve V-28-18 (Panel 1IF).
2.

Cycle Torus Vent valve V-28-47 (Panel 11F) to maintain Drywell pressure below 3.0 psig.

3.

IF the Torus cannot be vented, THEN perform the following:

a.

Inform the GSS/GOS.

b.

Open the Drywell vent valve V-23-21 (Panel 12XR).

c.

Cycle Drywell vent valve and V-23-22 (Panel 12XR) to maintain Drywell pressure below 3.0 psig.

(320002/10)

E8-3

Procedure EMG-3200.02 Support Proc.

32 Rev.

15 Attachment I Page I of 2 SUPPORT PROCEDURE 32 VENTING THE TORUS FOR PRIMARY CONTAINMENT HIGH PRESSURE 1.0 PREREQUISITES Torus venting has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for venting the Torus via the Reactor Building ventilation system.

2.1 Verify Torus water level is below 348 in.

(Panel IF/2F) 2.2 Evacuate personnel from the Reactor Building.

2.2.1 Sound the Reactor Building Evacuation Alarm Time 2.2.2 Make the announcement "Primary Containment Venting will commence in approximately 5 minutes.

All personnel evacuate the Reactor Building immediately.

Stand clear of the Stack and the Rx.

Bldg.

Fan Pad."

2.3 Select a SGTS Train for operation and place its fan control switch in HAND (Panel 11R).

2.4 Place the control switch for V-28-48, SGTS CROSSTIE, in CLOSED (Panel 11R).

2.5 Confirm Reactor Building Supply Fans secured (Panel 11R).

2.6 Confirm Reactor Building Exhaust Fan secured (Panel 11R).

2.7 Confirm that the Reactor Mode Selector Switch is NOT in the RUN position.

2,8 Obtain one (1) bypass plug from the EOP Tool Box in the Control Room.

2.9 CAUTION The containment isolation function of the following valves is bypassed when the High Drywell Pressure and Reactor Low Low Water Level isolation signals are defeated:

"* Drywell Nitrogen Makeup Valves (V-23-17 and V-23-18)

"* Torus Nitrogen Makeup Valves (V-23-19 and V-23-20)

Open the EOP BYPASS PLUGS panel in the rear of Panel 1OXF.

2.9.1 Insert a bypass plug in position BP5.

(320002/11)

E9-1

Procedure EMG-3200.02 Support Proc.

32 Rev.

15 Attachment I Page 2 of 2 2.10 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.10.1 Remove the bypass plug in position BP4.

2.10.2 Insert a bypass plug in position BPl.

2.11 Place the TORUS/DRYWELL ISOLATION VALVE BYPASS PERMISSIVE keylock switch in the TORUS position (Panel 11F).

2.12 Place the TORUS/DW VENT AND PURGE ISOL VLVS HI RAD BYP keylock switches for both Channels 1 & 2 in the BYPASS position (Panel 11F).

2.13 Inform GSS/GOS that the Torus is ready to be vented via the Torus Vent valves.

3.0 PROCEDURE When directed by the GOS/GSS, complete the following:

3.1 Reset the Reactor Building Ventilation System by momentarily depressing the system RESET pushbutton (Panel 11R).

3.2 Confirm open Reactor Building Main Exhaust Isolation valves V-28-21 and V-28-22 (Panel 11R).

3.3 WHEN at least five minutes has passed since sounding the Reactor Building evacuation alarm, THEN inform the GSS/GOS, AND start Reactor Building Exhaust Fan 1-5.

3.4 Open Torus Vent valves V-28-18 and V-28-47 (Panel 11F).

3.5 Inform the GSS/GOS that Torus venting via V-28-18 and V-28-47 has commenced.

3.6 Control Torus pressure as directed by the GSS/GOS by cycling the Torus vent valves as required.

3.7 CAUTION Ventilation ductwork failure can occur when venting through V-28-17 with torus pressure greater than 2 psig.

WHEN directed by the GSS/GOS, THEN open torus vent valve V-28-17 (Panel 11F).

3.8 Control Torus pressure as directed by the GSS/GOS by cycling Torus Vent valves as required.

(320002/11)

E9-2

Procedure EMG-3200.02 Support Proc.

33 Rev.

15 Attachment J Page 1 of 2 SUPPORT PROCEDURE 33 VENTING THE DRYWELL FOR PRIMARY CONTAINMENT HIGH PRESSURE 1.0 PREREQUISITES Drywell venting has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following-steps in-preparation-for venting the Drywell via the Reactor Building ventilation system.

2.1 Verify Primary Containment water level is below 461 in.

2.2 Evacuate personnel from the Reactor Building.

2.2.1 Sound the Reactor Building Evacuation Alarm.

Time 2.2.2 Make the announcement "Primary Containment VentinQ will commence in approximately five minutes.

All personnel evacuate the Reactor BuildinQ immediately.

Stand clear of the Stack and the Rx.

Bldg. Fan Pad."

2.3 Select a SGTS Train for operation and place its fan control switch in HAND (Panel 11R).

2.4 Place the control switch for V-28-48, SGTS CROSSTIE, in CLOSED (Panel 11R).

2.5 Confirm Reactor Building Supply Fans secured (Panel 11R).

2.6 Confirm Reactor Building Exhaust Fan secured (Panel 11R).

2.7 Confirm that the Reactor Mode Selector is NOT in the RUN position.

2.8 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.8.1 Remove the bypass plug in position BP4.

2.8.2 Insert the bypass plug in position BPI.

(320002/12)

El0-1

Procedure EMG-3200.02 Support Proc.

33 Rev.

15 Attachment J Page 2 of 2 2.9 Place the TORUS/DRYWELL ISOLATION VALVE BYPASS PERMISSIVE keylock switch in the DRYWELL position (Panel 11F).

2.10 Inform the GSS/GOS that the Drywell is ready to be vented via the Drywell 2 inch Vent valves.

3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Reset the Reactor Building Ventilation System by momentarily depressing the system RESET pushbutton (Panel 11R).

3.2 Confirm open Reactor Building Main Exhaust Isolation valves, V-28-21 and V-28-22 (Panel 11R).

3.3 WHEN at least five minutes has passed since sounding the Reactor Building evacuation alarm, THEN inform the GSS/GOS, AND start Reactor Building Exhaust Fan 1-5.

3.4 Open Drywell Vent valves V-23-21 and V-23-22 (Panel 12XR).

3.5 Control Drywell pressure as directed by the GSS/GOS by cycling V-23-21 or V-23-22.

(320002/12)

E10-2

Procedure EMG-3200.02 Support Proc.

34 Rev.

15 Attachment K Page 1 of 2 SUPPORT PROCEDURE 34 VENTING THE DRYWELL THROUGH THE PURGE SYSTEM FOR PRIMARY CONTAINMENT HIGH PRESSURE 1.0 PREREQUISITES Drywell venting through the Purge System has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for venting the Drywell via the Drywell Purge System and Reactor Building Ventilation System.

2.1 Evacuate personnel from the Reactor Building.

2.1.1 Sound the Reactor Building Evacuation Alarm.

Time 2.1.2 Make the announcement "Primary Containment Venting will commence in approximately five minutes.

All personnel evacuate the Reactor Building immediately.

Stand clear of the Stack and the Rx. Bldg.

Fan Pad."

"2.2 Select a SGTS Train for operation and place its fan in HAND (Pnl 11R) 2.3 Place Control switch for V-28-48, SGTS CROSSTIE, to the CLOSED position (Panel 11R).

2.4 Confirm Reactor Building Supply Fans are secured (Panel 11R).

2.5 Confirm Reactor Building Exhaust Fan secured (Panel 1IR).

2.6 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.6.1 Remove the bypass plug from position BP4.

2.6.2 Insert the bypass plug into position BPI.

2.7 CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS Keylock is in the BYPASS position:

  • Drywell Ventilation Isolation Valves (V-27-1,2,3 and 4).

"* Drywell Nitrogen Purge Inlet Valves (V-23-13 & V-23-14).

"* Torus Nitrogen Purge Inlet Valves (V-23-15 & V-23-16).

Place the CNTMT VENT AND PURGE ISOLATION BYPASS Keylock in BYPASS (Panel 12XR).

(320002/13)

E11-1

Procedure EMG-3200.02 Support Proc. 34 Rev.

15 Attachment K Page 2 of 2 2.8 Place the TORUS/DW VENT AND PURGE VLVS ISOL HI RAD BYPASS Keylock switches for both channels 1 and 2 in the BYPASS position (Panel 11F).

2.9 Confirm that the Torus to Reactor Building Vacuum Breaker (Absorp Cham Vac Rel V-26-16 and 18) control switch is in CLOSE position (Panel 11F).

2.10 Inform the GSS/GOS that the Drywell is ready to be vented via the Drywell Purge valves.

3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Reset the Reactor Building Ventilation System by momentarily depressing the system RESET pushbutton (Panel 11R).

3.2 Confirm open Reactor Building Main Exhaust Isolation Valves V-28-21 and V-28-22 (Panel 11R).

3.3 WHEN at least five minutes has passed since sounding the Reactor Building evacuation alarm, THEN Inform the GSS/GOS, AND start Reactor Building Exhaust Fan 1-5 (Panel 11R).

3.4 Confirm closed Drywell Air Supply Valves V-28-42 and V-28-43 (Panel 11R).

3.5 CAUTION Ventilation ductwork failure WILL occur when venting through V-27-3 and V-27-4 with Drywell pressure greater than 2 psig.

Open Drywell Purge Valve V-27-3 and V-27-4 (Panel 11F).

3.6 Control Drywell pressure as directed by the GSS/GOS, by cycling V-27-3 as required.

(320002/13)

E11-2

Procedure EMG-3200.02 Support Proc.

35 Rev. 15 Attachment L Page I of 2 SUPPORT PROCEDURE 35 VENTING THE TORUS THROUGH THE HARDENED VENT 1.0 PREREQUISITES Torus venting through the hardened vent has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 This procedure requires the-useof an MB-I key.

2.2 Verify Torus level is less than 348 in.

2.3 Verify Primary Containment H2 concentration is below 1.5%.

2.4 Verify CNTMT HI RANGE RAD MONITOR Channels 1 and 2 are reading below 2 x 10 4 R/HR (Panel 2R).

2.5 Confirm at least one exhaust fan; 1-5, 1-6, or 1-7 (Panel 1IR) is running.

2.6 Confirm N2 purge isolation valve V-23-195 closed (Outside Rx. Bldg.,

NE Corner).

2.7 Unlock and close N2 purge inlet valve V-23-357 (Outside Rx. Bldg. NE Corner) 2.8 Unlock and open the hardened vent stack isolation valve V-23-358 (Outside Rx. Bldg.,

NE Corner) 2.9 Inform the GSS/GOS that the.-Torus is ready to be vented through the hardened vent.

(320002/14)

E12-1

Procedure EMG-3200.02 Support Proc. 35 Rev.

15 Attachment L Page 2 of 2 3.0 PROCEDURE When directed by the GSS/GOS, complete 3.1 Make the following announcement:

TI AROUT TO COMMENCE THROUGH THE STAND CLEAR OF THE RX.

BLDG.

FAN the following:

"PRIMARY CONTAINMENT VENTING T4rwT*.T VFNT ArT.T PF.R*nNNE PAD.

THE STACK AND THE RCA

YARD, NORTH AND EAST OF THE RX.

BLDG."

3.2 Place the CNTMT VENT AND PURGE ISOLATION BYPASS keylock in BYPASS (Panel 12XR).

3.3 Open Torus nitrogen purge inlet valves V-23-15 and V-23-16 (Panel 12XR).

3.4 Inform the GSS/GOS that Torus venting has begun.

3.5 Control Torus pressure as directed by cycling V-23-16 (Panel 12XR).

(320002/14)

CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS keylock is in the BYPASS position:

  • Drywell Ventilation Isolation Valves (V-27-1, 2,

3, and 4).

  • Drywell Nitrogen Purge Inlet Valves (V-23-13 & V-23-14).
  • Torus Nitrogen Purge Inlet Valves (V-23-15 & V-23-16).

E12-2 HARDENED VENT ALL PERSONNEL I

Procedure EMG-3200.02 Support Proc.

36 Rev.

15 Attachment M Page 1 of 2 SUPPORT PROCEDURE 36 VENTING THE DRYWELL THROUGH THE HARDENED VENT 1.0 PREREQUISITES Drywell venting through the hardened vent has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 This procedure requires the use of an MB-I key.

2.2 Verify Primary Containment H2 concentration is below 1.5%.

2.3 Verify CNTMT HI RANGE RAD MONITOR Channels 1 and 2 are reading below 2 x 104 R/HR (Panel 2R).

2.4 Confirm at least one exhaust fan; 1-5, 1-6, or 1-7 (Panel 1IR) is running.

2.5 Confirm N2 purge isolation valve V-23-195 closed (Outside Rx. Bldg.

NE Corner).

2.6 Unlock and close N2 purge inlet valve V-23-357 (Outside Rx. Bldg. NE Corner) 2.7 Unlock and open the hardened vent stack isolation valve V-23-358 (Outside Rx. Bldg.,

NE Corner) 2.8 Inform the GSS/GOS that the Drywell is ready to be vented through the hardened vent.

(320002/15)

E13-1

Procedure EMG-3200.02 Support Proc.

36 Rev.

15 Attachment M Page 2 of 2 3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Make the following announcement:

"PRIMARY CONTAINMENT VENTING IS ABOUT TO COMMENCE TROUGH THE HARDENED VENT.

ALL PERSONNEL STAND CLEAR OF THE RX.

BLDG.

FAN PAD, THE STACK AND THE RCA

YARD, NORTH AND EAST OF THE RX.

BLDG."

3.2 CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS keylock is in the BYPASS position:

  • Drywell Ventilation Isolation Valves (V-27-1, 2,

3, and 4).

  • Drywell Nitrogen Purge Inlet Valves (V-23-13 & V-23-14).

1 Torus Nitrogen Purge Inlet Valves (V-23-15 & V-23-16).

Place the CNTMT VENT AND PURGE ISOLATION BYPASS keylock in BYPASS (Panel 12XR).

3.3 Open Drywell nitrogen purge inlet valves V-23-13 and V-23-14 (Panel 12XR).

3.4 Inform the GSS/GOS that Drywell venting has begun.

3.5 Control Drywell pressure as directed by cycling V-23-14.

(320002/15)

E13-2

Procedure EMG-3200.02 Support Proc.

37 Rev.

15 Attachment N Page 1 of 6 SUPPORT PROCEDURE 37 MAKEUP TO THE TORUS VIA CORE SPRAY SYSTEM 1.0 PREREQUISITES 1.1 Makeup to the Torus via the Core Spray System has been directed by the Emergency Operating Procedures.

1.2 One Core Spray System is available and not required to assure adequate core cooling.

1.3 The Reactor Building is accessible.

2.0 PREPARATION 2.1 IF Core Spray actuating signals are present, THEN override Core Spray initiation logic by depressing the OVERRIDE switches for all the sensors that are lit and depressing all ACTUATED switches, whether lit or unlit.

2.2 An MB-I key is required if lining up the CST as source of Torus water makeup.

3.0 PROCEDURE 3.1 NOTE Overriding Core Spray initiation logic may be required.

IF Core Spray System 1 has been designated to be used, THEN Perform the following; 3.1.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 1 (Panel IF/2F).

3.1.2 Close Core Spray System 1 Suction valves V-20-3 and V-20-32 (Panel lF/2F).

3.1.3 Confirm closed Core Spray System 1 Parallel Isolation valves V-20-15 and V-20-40 (Panel IF/2F).

(320002/16)

E14-1

Procedure EMG-3200.02 Support Proc.

37 Rev.

15 Attachment N Page 2 of 6 3.1.4 IF the NW Corner Room is accessible, AND the CST is the source of Torus water makeup, THEN perform the following:

1. Place the breakers for Core Spray Pump Suction Valves V-20-3 and V-20-32 in the OFF position.

"* V-20-3 Bkr.

(MCC lA21A/RB 23 SW)

"* V-20-32 Bkr.

(MCC lB21A/RB 23 NE)

2.

Unlock and open the following CST supply valves

"* V-20-1 (NW Corner Room)

"* V-20-5 (NW Corner Room)

"* V-20-34 (NW Corner Room)

3.

Start Core Spray System 1 Main Pump NZ01A or NZO0C.

3.1.5 IF the NW Corner Room is NOT accessible, THEN perform the following to use fire water as the source of Torus water makeup:

1. Close Tell-Tale Drain Valve V-20-91 (North Side RB).
2.

Start the Diesel Fire Pumps by placing their switches in MAN position (Panel 13R).

3.

Open Fire Protection Supply Valve V-20-83 (North Side RB).

4.

Place Core Spray System 1 Main Pump control switches in the PULL-TO-LOCK position (Panel IF/2F).'

3.1.6 Unlock and place the breaker for Torus Test Flow Return Valve V-20-27 in the ON position (MCC lA21B/RB 23 E).

3.1.7 Open Test Flow Return valve V-20-27 (Keylock RB 51'NW).

(320002/16)

E14-2

Procedure EMG-3200.02 Support Proc.

37 Rev.

15 Attachment N Page 3 of 6 3.1.8 WHEN Torus level is greater than 143 in.

but less than 154 in.,

THEN perform the following:

1. IF the CST was the source of Torus water
makeup, THEN Perform the following:
a.

Close the Test Flow Return Valve V-20-27 (keylock RB 51 NW).

b.

Secure the Core Spray System 1 Main Pumps started in Step 3.1.4.3.

2.

IF fire water was the source of Torus water

makeup, THEN perform the following:
a.

Close the Test Flow Return Valve V-20-27 (keylock RB 51 NW)

b.

Close Fire Protection Supply Valve V-20-83 (North Side RB).

c.

Secure the Diesel Fire Pumps by taking their control switches in AUTO position (Panel 13R).

d.

Open Tell-Tale Drain Valve V-20-91 (North Side RB).

3.1.9 When filling is no longer required:

1.

IF the CST was the source of Torus water makeup, THEN close and lock the following valves:

  • V-20-1 (NW Corner Room)
  • V-20-5 (NW Corner Room)
  • V-20-34 (NW Corner Room)
2.

Confirm closed Torus Test Flow Return Valve V-20-27 (Panel IF/2F)

3.

Place and lock the breaker for V-20-27 in the OFF position (MCC lA21B/RB 23 E)

(320002/16)

E14-3

Procedure EMG-3200.02 Support Proc.

37 Rev.

15 Attachment N Page 4 of 6

4.

Confirm the breakers for Core Spray Pump Suction Valves V-20-3 and V-20-32 in the ON position.

"* V-20-3 Bkr (MCC lA21A/RB 23 SW)

"* V-20-32 Bkr (MCC IB21A/RB 23 NE)

5.

Open Core Spray Pump Suction Valves V-20-3 and V-20-32 (Panel IF/2F).

6.

IF Fire water was the source of-torus-water makeup, THEN return Core Spray System 1 Main Pump control switches to the normal mid position (Panel lF/2F).

7.

Verify Core Spray KEEP FILL TROUBLE (B-3-d) alarm is not illuminated.

NOTE Overriding Core Spray initiation logic may be required.

IF Core Spray System 2 has been designated to be used, THEN perform the following:

3.2.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 2 (Panel lF/2F).

3.2.2 Close Core Spray System 2 Suction valves V-20-4 and V-20-33 (Panel iF/2F).

3.2.3 Confirm closed Parallel Isolation valves V-20-21 and V-20-41 (Panel 1F/2F).

3.2.4 IF the NW and SW Corner Rooms are accessible AND the CST is the source of Torus water makeup, THEN perform the following:

1. Place the breakers for Core Spray Pump Suction Valves V-20-4 and V-20-33 in the OFF position.

"* V-20-4 Bkr (MCC lB21A/RB 23 NE)

"* V-20-33 Bkr (MCC lA21A/RB 23 SW)

(320002/16) 3.2 E14-4

Procedure EMG-3200.02 Support Proc.

37 Rev.

15 Attachment N Page 5 of 6

2.

Unlock and open the following CST supply valves:

"* V-20-1 (NW Corner Room)

"* V-20-2 (SW Corner Room)

"* V-20-35 (SW Corner Room)

3.

Start Core Spray System 2 Main Pump NZ01B or NZ01D.

3.2.5 IF the NW or SW Corner Room is NOT accessible THEN perform the following to use firewater as the source of Torus water makeup:

1. Close Tell-Tale Drain Valve V-20-90 (South Side RB).
2.

Start the Diesel Fire Pumps by placing their switches in MAN position (Panel 13R)

3.

Open Fire Protection Supply Valve V-20-82 (South Side RB).

4.

Place Core Spray System 2 Main Pump control switches in the PULL-TO-LOCK position (Panel IF/2F).

3.2.6 Unlock and place the breaker for Torus Test Flow Return Valve V-20-26 in the ON position (MCC IB21A/RB 23 NE).

3.2.7 Open Test Flow Return valve V-20-26 (Keylock RB 75 SW).

3.2.8 WHEN Torus level is greater than 143 in.

but less than 154 in.,

THEN perform the following:

1. IF the CST was the source of Torus water makeup, THEN perform the following:
a.

Close the Test Flow Return Valve V-20-26 (keylock RB 75 SW)

b.

Secure the Core Spray System 2 Main Pumps started in Step 3.2.4.3

2.

IF fire water was the source of Torus water makeup, THEN perform the following:

a.

Close the Test Flow Return Valve V-20-26 (keylock RB 75 SW)

(320002/16)

E14-5

Procedure EMG-3200.02 Support Proc.

37 Rev.

15 Attachment N Page 6 of 6

b.

Close Fire Protection Supply Valve V-20-82 (South Side RB).

c.

Secure the Diesel Fire Pumps by taking their control switches in AUTO position (Panel 13R).

d.

Open Tell-Tale Drain Valve V-20-90 (South Side RB).

3.2.9 When filling is no longer required:

1.

IF the CST was the source of Torus water makeup, THEN close and lock the following valves:

"* V-20-1 (NW Corner Room)

"* V-20-2 (SW Corner Room)

"* V-20-35 (SW Corner Room)

2.

Confirm closed Torus Test Flow Return Valve V-20-26 (Panel IF/2F).

3.

Place and lock the breaker for V-20-26 in the OFF position (MCC IB21A/RB 23 NE).

4.

Confirm the breakers for Core Spray Pump Suction Valves V-20-4 and V-20-33 in the ON position.

V-20-4 Bkr (MCC IB21A/RB 23 NE)

V-20-33 Bkr (MCC IA21A/RB 23 SW)

5.

Open Core Spray Pump Suction Valves V-20-4 and V-20-33 (Panel IF/2F).

6.

IF Fire water was the source of torus water makeup, THEN return Core Spray System 2 Main Pump control switches to the normal mid position (Panel IF/2F).

7.

Verify Core Spray KEEP FILL TROUBLE (B-3-d) alarm is not illuminated.

(320002/16)

E14-6

Procedure EMG-3200.02 Support Proc.

38 Rev.

15 Page 1 of 4 SUPPORT PROCEDURE 38 DETERMINING PRIMARY CONTAINMENT WATER LEVEL 1.0 PREREQUISITES 1.1 Determination of Primary Containment Water Level has been directed by the Emergency Operating Procedures.

1.2 Primary Containment Water Level is greater than the range of the wide range Torus level recorder (0-360 inches) on Panel 16R.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Calculate Primary Containment Water Level by completing the following:

3.1.1 Record Torus pressure from one of the following:

1. Digital indicator on Panel 4F
2.

Computer Point ID PTIP12

3.

PT-IP12 on Panel IF/2F P(Torus) =

psig 3.1.2 Record Drywell pressure from PI-IP08 on Panel IF/2F P(DW)

=

psig 3.1.3 Calculate AP AP = P(Torus)

P(DW)

=

psid 3.1.4 IF AP is greater than 16 psid THEN continue at Step 3.2 of this procedure 3.1.5 Determine Primary Containment Water Level using Figure 38-1.

3.2 IF Torus -

DW AP is greater than 16 psid THEN calculate Primary.Containment Water Level by completing the following:

3.2.1 Record Torus pressure from one of the following:

1. Digital indicator on Panel 4F
2.

Computer Point ID PTIP12

3.

PT-IP12 on Panel IF/2F P(Torus)

=

psig.

(320002/17)

E15-1

Procedure EMG-3200.02 Support Proc.

38 Rev.

15 Page 2 of 4 3.2.2 Record Drywell pressure from Pen 3 of Recorder 12XR-6 (Panel 12XR)

P(DW) psig 3.2.3 Calculate AP AP = P(Torus)

P(DW)=

psid 3.2.4 Determine Primary Containment Water Level using Figure 38-2.

(320002/17)

E15-2

Procedure EMG-3200.02 Support Proc.

38 Rev.

15 Page 3 of 4 Figure 38-1 Containment Water Level Determination Using DW Pressure Indication From Panel 1F/2F 800-.........

750 725.

  • 700+

7 0

0 675

"- 625.

_z6 O0....................

"7 55 647.-.

4" (43* 7 pidn;s 45.ichs) 50>

50 -..................

r 3IJ 75 2S

....................i.....

O 1 2

3 4 5

6 7

8 9 1011 12131415161718 P(Torus)

P(DW)

= psid (320002/17)

El5-3

Procedure EMG-3200.02 Support Proc.

38 Rev.

15 Page 4 of 4 Fiqure 38-2 Containment Water Level Determination Usinq DW Pressure Indication From Pen 3 of Recorder 12XR-6 (Panel 12XR) 1300-...................-..............

11 0

  • .....°°

,....,.....J.

  • °.-.

1 25 12 5 0 10250........................

"......-':--"----:/'-.....

.....................(31...9 :pi....252 inch.,

es',

200......

- i-000 K

9 75.......

9*125:-:.................

.15 ~ ~

~

~

(ý.

p~id 17--

1810122345627223

.3233 '

3 E000 C-9 7 5........

95 825-i!

i i

T ii 7 7 5....

7 5 0 1.. I.t... [. J.-.I.. L.I...

L...

...l.

.I.

.15 16 17 18 19 20 21 22 23 2425 26 27 28 29 30 3,:. 7-2 3'23

.35 P(morus) -

PODW)

=psid (320002/17)

E15-4

Procedure EMG-3200.02 Support Proc.

39 Rev.

15 Attachment P Page 1 of 2 SUPPORT PROCEDURE 39 PLACING THE H2/02 MONITORING SYSTEM IN SERVICE 1.0 PREREQUISITES Placing the H2/02 Monitoring System in service has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Placing Channel A in service (Panel 16R):

3.1.1 Place switch for V-38-37 to OPEN 3.1.2 Place switch for V-38-38 to OPEN 3.1.3 Place switch for V-38-39 to OPEN 3.1.4 Place switch for V-38-40 to OPEN NOTE When switching to the ANALYZE mode, a system trouble alarm may occur due to analyzer cell low flow.

3.1.5 3.1.6 3.2 Placing 3.2.1 3.2.2 3.2.3 Place mode switch in ANALYZE.

IF DW H2/02 SYS A TROUBLE alarm (C-8-f) annunciates, THEN acknowledge the alarm and reset,by depressing the ALARM RESET pushbutton (Panel 16R).

Channel B in service (Panel 16R):

Place switch for V-38-41 to OPEN.

Place switch for V-38-43 to OPEN.

Place switch for V-38-44 to OPEN.

(320002/18)

E16-1

Procedure EMG-3200.02 Support Proc.

39 Rev.

15 Attachment P Page 2 of 2 3.2.4 Place switch for V-38-46 to OPEN.

NOTE When switching to the ANALYZE mode, a system trouble alarm may occur due to analyzer cell low flow.

3.2.5 Place mode switch in ANALYZE.

3.2.6 IF DW H2/02 SYS B TROUBLE alarm (C-8-g) annunciates, THEN acknowledge the alarm and reset by depressing the ALARM RESET pushbutton (Panel 16R).

3.3 Record time.

Time 3.4 NOTE A five (5) minute stabilization period is required after switching an analyzer from STANDBY to ANALYZE.

After a minimum 5 minute wait time, observe H2 and 02 concentrations.

(320002/18)

E16-2

Procedure EMG-3200.02 Support Proc. 40 Rev.

15 Attachment Q Page 1 of 1 SUPPORT PROCEDURE 40 ISOLATION OF THE PRIMARY CONTAINMENT VENT AND PURGE VALVES 1.0 PREREQUISITES Isolation of the Primary Containment Vent and Purge Valves has been directed by the Emergency Operating Procedures.

2.0 PREPARATION NONE 3.0 PROCEDURE closed the vent and purge valves that are Containment Pressure Control.

System Valve No.

DW Vent/Purge V-27-1 V-27-2 V-27-3 V-27-4 Torus Vent V-28-17 V-28-18 Torus 2" Vent Bypass V-28-47 DW 2" Vent Bypass V-23-21 V-23-22 N2Purge V-23-13 V-23-14 V-23-15 V-23-16 N2Makeup V-23-17 V-23-18 V-23-19 V-23-20 NOT being used to:

Panel 11F 11F 11F 11F 1IF 11F 11F 12XR 12XR 12XR 12XR 12XR 12XR 12XR 12XR 12XR 12XR (320002/19)

Confirm Primary E17-1 r

Procedure EMG-3200.02 Support Proc. 41 Rev.

15 Attachment R Page 1 of 2 SUPPORT PROCEDURE 41 VENTING THE TORUS FOR HYDROGEN CONTROL 1.0 PREREQUISITES Torus venting has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for venting the Torus via the Reactor Building Ventilation System.

2.1 Verify Torus water level is below 348 in.

2.2 Evacuate personnel from the Reactor Building.

2.2.1 Sound the Reactor Building Evacuation Alarm.

Time 2.2.2 Make the announcement, "Primary Containment Venting will commence in approximately 5 minutes.

All personnel evacuate the Reactor Building immediately.

Stand clear of the Stack and the Rx.

Bldg.

Fan Pad."

2.3 Select a SGTS Train for operation and place its fan control switch in HAND (Panel 11R).

2.4 Place control switch for V-28-48, SGTS CROSSTIE, in CLOSED (Panel 11R).

2.5 Confirm Reactor Building Supply Fans secured (Panel 11R).

2.6 Confirm Reactor Building Exhaust Fan secured (Panel 11R).

2.7 Confirm that the Reactor Mode Selector Switch is NOT in the RUN position (Panel 4F).

2.8 Obtain a bypass plug from the EOP Tool Box in the Control Room.

2.9 CAUTION The containment isolation function of the following valves is bypassed when the High Drywell Pressure and Reactor Low Low Water Level Isolation signals are defeated:

"* Drywell Nitrogen Makeup Valves (V-23-17 and V-23-18)

"* Torus Nitrogen Makeup Valves (V-23-19 and V-23-20)

Open the EOP BYPASS PLUGS panel inside Panel 1OXF.

2.9.1 Insert a bypass plug in position BP5.

(320002/20)

E18-1

Procedure EMG-3200.02 Support Proc.

41 Rev.

15 Attachment R Page 2 of 2 2.10 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.10.1 Remove the bypass plug from position BP4.

2.10.2 Insert a bypass plug into position BPl.

2.11 Place the TORUS/DRYWELL ISOLATION VALVE BYPASS PERMISSIVE keylock switch in TORUS position (Panel 11F).

2.12 Place the TORUS/DW VENT AND PURGE ISOL VLVS HI RAD BYP keylock switches for both Channels 1 and 2 in the BYPASS position (Panel 11F).

2.13 Inform the GSS/GOS that the Torus is ready to be vented via the Torus Vent valves.

3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Reset the Reactor Building Ventilation System by momentarily depressing the system RESET pushbutton (Panel 11R).

3.2 Confirm open Reactor Building Main Exhaust Isolation valves V-28-21 and V-28-22 (Panel 11R).

3.3 WHEN at least five minutes have passed since sounding the Reactor Building Evacuation Alarm, THEN inform the GSS/GOS, AND start Reactor Building Exhaust Fan 1-5 (Panel 11R).

3.4 Open Torus Vent valves V-28-18 and V-28-47 (Panel 11F).

3.5 Inform the GSS/GOS that Torus venting via V-28-18 and V-28-47 has commenced.

3.6 WHEN Torus pressure is below 2 psig, THEN inform the GSS/GOS and open Torus Vent valve V-28-17 (320002/20)

E18-2

Procedure EMG-3200.02 Support Proc.

42 Rev. 15 Attachment S Page 1 of 4 SUPPORT PROCEDURE 42 PURGING THE DRYWELL FOR HYDROGEN CONTROL 1.0 PREREQUISITES Purging the Drywell has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in.preparation for purging-the Drywell.

2.1 Station an Equipment Operator and establish communications between the Nitrogen Supply Station and the Control Room.

2.2 CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS Keylock is in the BYPASS position:

9 Drywell Ventilation Isolation Valves (V-27-1, 2,

3 and 4)

  • Drywell Nitrogen Purge Inlet Valves (V-23-13 and V-23-14) e Torus Nitrogen Purge Inlet Valves (V-23-15 and V-23-16)

Place the CNTMT VENT AND PURGE ISOLATION BYPASS keylock (Panel 12XR) in the BYPASS position.

2.3 Confirm that the ABSORP CHAM VAC REL (Torus to Reactor Building Vacuum Breakers, V-26-16 and V-26-18) control switch in the CLOSE positiotl (Panel 11F).

2.4 Confirm open Purge Line Isolation Valve V-23-357 (NE corner RB, outside) 2.5 Confirm open Drywell Purge Isolation Valve V-23-195 (NE corner RB, outside) 2.6 Inform the GSS/GOS that nitrogen purging of the Drywell is ready to commence.

(320002/21)

E19-1

Procedure EMG-3200.02 Support Proc.

42 Rev.

15 Attachment S Page 2 of 4 3.0 PROCEDURE When directed by the GSS/GOS, perform the following:

NOTE All valves and electrical components, unless noted otherwise, are located at the Nitrogen Pad.

3.1 Line up nitrogen supply to the Drywell by opening valves V-23-13 and V-23-14 (Panel 12XR).

3.2 Prepare the nitrogen vaporizer for purging by completing the following:

3.2.1 Confirm the following knife switches in the ON position:

"* SW-854-167

"* SW-854-168

"* SW-854-165 3.2.2 On the selected heater control cabinet (HTR-854-165 or 166),

complete the following:

  • Place the power switch in ON position (upper right hand side) 0 Place the power control switch in ON position 0 Verify that the POWER ON light is lit 3.2.3 Confirm that there is no debris below or in the area around the nitrogen vaporizer.

3.2.4 Place the knife switch for M-23-1 in ON position.

3.2.5 CAUTION The following step will start the nitrogen vaporizer fan which blows down.

Hearing and eye protection is required.

Place the control switch for M-23-1 in HAND position.

(320002/21)

E19-2

Procedure EMG-3200.02 Support Proc.

42 Rev.

15 Attachment S Page 3 of 4 3.3 Crack open, then completely open the nitrogen supply tank outlet to vaporizer valve V-23-268.

3.4 Crack open, then completely open the inlet and outlet valves for the selected heater:

HTR-854-165 HTR-854-166 Inlet Valve V-23-363 V-23-365 Outlet Valve V-23-364 V-23-366 3.5 Place the thermostatic regulating valve in service by opening valves V-23-186 and V-23-187.

3.6 Select a Grove Reducer and open the appropriate inlet, outlet and supply valves:

Grove Reducer V-23-235 V-23-234 Inlet Valve V-23-189 V-23-190 Outlet Valve V-23-191 V-23-192 SupPly Valve V-23-193 V-23-194 3.7 Establish nitrogen purge flow by completing the following:

3.7.1 Using a wrench, turn the control valve on top of the selected Grove Reducer in the clockwise direction until pressure as indicated on PI-854-1732 is 55 psig.

3.7.2 Verify purge flow on the NITROGEN PURGE & MAKEUP FLOW Recorder (Panel 12XR).

(320002/21)

E19-3

Procedure EMG-3200.02 Support Proc.

42 Rev.

15 Attachment S Page 4 of 4 Confirm N2 temperature 65-95°F as indicated on the PURGE N2 TEMP gauge (Panel 12XR).

3.7.4 IF ambient temperature is greater than 80'F, 3.8 Inform 3.9 WHEN THEN AND N2 temperature is above 95°F as indicated on the PURGE N TEMP gauge (Panel 12XR)

THEN secure the nitrogen vaporizer fan by placing the control switch for M-23-001 in OFF position.

the GOS/GSS that Drywell purging has commenced.

directed to secure the nitrogen purge, close Drywell Nitrogen purge valves V-23-13 and V-23-14 (Panel 12XR).

(320002/21) 3.7.3 NOTE Initial temperature could be 20 to 30OF above nominal setpoints of 80'F.

After 5 to 10 minutes, dependent on ambient temperature, temperature will stabilize.

CAUTION The temperature range of 65°-95°F as read in the Control Room is important to prevent brittle fracture and cracking of piping within the containment.

E19-4

Procedure EMG-3200.02 Support Proc. 43 Rev.

15 Attachment T Page 1 of 3 SUPPORT PROCEDURE 43 VENTING THE DRYWELL FOR HYDROGEN CONTROL (LEVEL BELOW 461 IN) 1.0 PREREQUISITES Drywell venting has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for venting the Drywell via the Reactor Building Ventilation System.

2.1 Verify Primary Containment water level is below 461 in.

2.2 Evacuate personnel from the Reactor Building.

2.2.1 Sound the Reactor Building Evacuation Alarm.

Time 2.2.2 Make the announcement, "Primary Containment Venting will commence in approximately five minutes.

All personnel evacuate the Reactor Building immediately.

Stand clear of the Stack and the Rx. Bldg.

Fan Pad".

2.3 Select a SGTS Train for operation and place its fan control switch in HAND (Panel 11R).

2.4 Place control switch for V-28-48, SGTS CROSSTIE, in CLOSED (Panel 11R).

2.5 Confirm Reactor Building Supply Fans secured (Panel 11R).

2.6 Confirm Reactor Building Exhaust Fan secured (Panel 11R).

2.7 Confirm that the Reactor Mode Selector switch is NOT in RUN (Panel 4F).

2.8 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.8.1 Remove the bypass plug from position BP4.

2.8.2 Insert the bypass plug into position BPI.

2.9 Place the TORUS/DRYWELL ISOLATION VALVE BYPASS PERMISSIVE keylock switch in the DRYWELL position (Panel 11F).

(320002/22)

E20-1

Procedure EMG-3200.02 Support Proc. 43 Rev. 15 Attachment T Page 2 of 3 2.10 Place the TORUS/DW VENT AND PURGE ISOL VLVS HI RAD BYPASS keylock switches for both Channels 1 and 2 in the BYPASS position (Panel 11F).

2.11 CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS is in the.BYPASS position:

"* Drywell Ventilation Isolation Valves (V-27-1,2,3 & 4)

"* Drywell Nitrogen Purge Inlet Valves (V-23-13 & V-23-14)

  • Torus Nitrogen Purge Inlet Valves (V-23-15 & V-23-16)

Place the CNTMT VENT AND PURGE ISOLATION BYPASS Keylock in BYPASS position (Panel 12XR).

2.12 Inform the GSS/GOS that the Drywell is ready to be vented via the Drywell Vent valves.

3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Reset the Reactor Building Ventilation System by momentarily depressing the system RESET pushbutton (Panel 11R).

3.2 Confirm open Reactor Building Main Exhaust Isolation valves, V-28-21 and V-28-22 (Panel 11R).

3.3 WHEN at least five minutes have passed since sounding the Reactor Building Evacuation Alarm, THEN inform the GSS/GOS, AND start Reactor Building Exhaust Fan 1-5 (Panel 11R).

3.4 Open Drywell Vent valves V-23-21 and V-23-22 (Panel 12XR).

3.5 Inform the GSS/GOS that Drywell venting via V-23-21 and V-23-22 has commenced.

(320002/22)

E20-2

Procedure EMG-3200.02 Support Proc.

43 Rev.

15 Attachment T Page 3 of 3 3.6 WHEN Drywell Pressure is below 2 psig, THEN inform the GSS/GOS, AND open Drywell Vent valves V-27-1 and V-27-2.

(320002/22)

E20-3

Procedure EMG-3200.02 Support Proc.

44 Rev.

15 Attachment U Page 1 of 4 SUPPORT PROCEDURE 44 VENTING THE DRYWELL THROUGH THE Rx BUILDING SUPPLY FANS FOR HYDROGEN CONTROL (LEVEL ABOVE 461 IN) 1.0 PREREQUISITES Drywell venting has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for venting the Drywell via the Rx Building Supply Fans.

2.1 Select a SGTS Train for operation and place its fan control switch in HAND (Panel 11R).

2.2 Place control switch for V-28-48, SGTS CROSSTIE, in CLOSE (Panel 11R).

2.3 Confirm Reactor Building Supply Fans secured (Panel 11R).

2.4 Confirm Reactor Building Exhaust Fan secured (Panel 11R).

2.5 Confirm closed Reactor Building Ventilation Isolation dampers V-28-1 through V-28-16 and V-28-36 through V-28-39 (Panel 1IR).

2.6 Place TORUS/DW VENT AND PURGE ISOL VLVS HI RAD BYPASS keylock switches for both Channels I and 2 in BYPASS (Panel 11F).

2.7 Confirm Reactor Building to Torus Vacuum Breakers V-26-16 and V-26-18 control switch in CLOSE position (Panel 11F).

(320002/23)

E21-1

Procedure EMG-3200.02 Support Proc.

44 Rev.

15 Attachment U Page 2 of 4 Place the CNTMT VENT AND PURGE ISOLATION BYPASS keylock in the BYPASS position (Panel 12XR).

2.9 Obtain two bypass plugs from the EOP Tool Box in the Control Room.

2.10 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.10.1 Insert a bypass plug into position BP2..

2.10.2 Insert a bypass plug into position BP3.

2.11 NOTE The tools that are required to complete this step are stored in the EOP Tool Box in the Control Room.

On the a back Fans:

2.11.1 2.11.2 Office Building Roof, perform the following to establish flow path through one of the Reactor Building Supply Disconnect the air operator linkages on the automatic damper of one Reactor Building Supply Fan:

Suppl Fan Automatic Damper SF-1-12 DM-28-42 SF-1-13 DM-28-43 SF-1-14 DM-28-41 Manually open the automatic damper for the supply fan selected.

(320002/23) 2.8 CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS keylock is in the BYPASS position:

"* Drywell Ventilation Isolation Valves (V-27-1,2,3 & 4)

"* Drywell Nitrogen Purge Inlet Valves (V-23-13 & V-23-14)

"* Torus Nitrogen Purge Inlet Valves (V-23-15 & V-23-16)

E21-2

Procedure EMG-3200.02 Support Proc.

44 Rev.

15 Attachment U Page 3 of 4 2.11.3 Secure the automatic damper in the open position by tightening the wing nuts on the damper positioning device.

2.11.4 Confirm open the manual damper downstream of the supply fan chosen.

Supply Fan Manual Damper SF-1-12 DM-28-46 SF-1-13 DM-28-47 SF-1-14 DM-28-48 2.11.5 Secure the manual damper in the open position by tightening the wing nuts on the damper positioning device 2.12 Evacuate personnel from the Reactor Building and Main Office Building 2.12.1 Sound the Reactor Building Evacuation Alarm.

Time 2.12.2 Make the announcement, "Primary Containment Ventinq will commence in approximately five minutes.

All personnel evacuate the Reactor Building and Main Office Building immediately".

2.13 CAUTION Contamination of the Control Room HVAC System may result when venting through V-27-3 and V-27-4.

Place the Control Room Ventilation in Full Recirculation Mode as follows:

2.13.1 Place the Control Room HVAC Damper Control switch in FULL RECIRC position (SYS A Panel IIR/SYS B Panel 9XR).

2.13.2 Confirm exhaust fan EF-l-24 control switch is OFF (Control Room behind Panel 1lF) and its damper is closed (CR Bathroom)

(320002/23)

E21-3

Procedure EMG-3200.02 Support Proc.

44 Rev. 15 Attachment U Page 4 of 4 3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Reset the Drywell Isolation Signal-by momentarily depressing the DRYWELL ISOLATION reset pushbutton (Panel 4F).

3.2 WHEN at least five minutes has passed since sounding the Reactor Building evacuation alarm THEN inform the GSS/GOS and perform the following:

3.2.1 Open drywell air supply valves V-28-42 and V-28-43 (Panel 11R).

3.2.2 Open drywell purge valves V-27-3 and V-27-4 (Panel 11F).

3.3 Inform the GSS/GOS that Drywell Venting has commenced.

(320002/23)

CAUTION An unmonitored, ground level release of radioactive gases will result from venting the primary containment via the Reactor Building Supply Fans.

CAUTION Contamination of the Main Office Building may result from venting the primary containment through purge valves V-27-3, V-27-4, and the Reactor Building Supply Fans.

E21-4

Procedure EMG-3200.02 Support Proc.

45 Rev.

15 Attachment V Page 1 of 4 SUPPORT PROCEDURE 45 PURGING THE TORUS FOR HYDROGEN CONTROL 1.0 PREREQUISITES Purging the Torus has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for purging the Torus.

2.1 Station an Equipment Operator and establish communications between the Nitrogen Supply Station and the Control Room.

2.2 CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS keylock is in the BYPASS position:

"* Drywell Ventilation Isolation Valves (V-27-1, 2,

3, and 4)

"* Drywell Nitrogen Purge Inlet Valves (V-23-13 and V-23-14)

  • Torus Nitrogen Purge Inlet Valves (V-23-15 and V-23-16)

Place the CNTMT VENT AND PURGE ISOLATION BYPASS keylock (Panel 12XR) in the BYPASS position.

2.3 Confirm that the ABSORP CHAM VAC REL (Torus to Reactor Building Vacuum Breakers, V-26-16 and V-26-18) control switch in the CLOSE positioi1 (Panel 11F).

2.4 Confirm open Purge Line Isolation Valve V-23-357 (NE corner RB, outside).

2.5 Confirm open Drywell Purge Isolation Valve V-23-195 (NE corner RB, outside).

2.6 Inform the GSS/GOS that nitrogen purging of the Torus is ready to commence (320002/24)

E22-1

Procedure EMG-3200.02 Support Proc.

45 Rev.

15 Attachment V Page 2 of 4 3.0 PROCEDURE When directed by the GSS/GOS, perform the following:

NOTE All valves and electrical components, unless noted otherwise, are located at the Nitrogen Pad.

3.1 Line up nitrogen supply to the Torus by opening valves V-23-15 and V-23-16 (Panel 12XR).

3.2 Prepare the nitrogen vaporizer for purging by completing the following:

3.2.1 Confirm the following knife switches in the ON position:

"* SW-854-167

"* SW-854-168

"* SW-854-165 3.2.2 On the selected heater control cabinet (HTR-854-165 or 166),

complete the following:

  • Place the power switch in ON position (upper right hand side)
  • Place the power control switch in ON position.
  • Verify that the POWER ON light is lit.

3.2.3 Confirm that there is no debris below or in the area around the nitrogen vaporizer.

3.2.4 Place the knife switch for M-23-1 in ON position.

3.2.5 CAUTION The following step will start the nitrogen vaporizer fan which blows down.

Hearing and eye protection is required.

Place the control switch for M-23-1 in HAND position.

(320002/24)

E22-2

3.3 Crack open, then completely open to vaporizer valve V-23-268.

3.4 Crack open, then completely open the selected heater:

HTR-854-165 Inlet Valve V-23-363 Outlet Valve V-23-364 3.5 Place the thermostatic regulating valves V-23-186 and V-23-187.

3.6 Select a Grove Reducer and open ti and supply valves:

Grove Reducer Inlet Valve Outlet Valve Supply Valve V-23-235 V-23-189 V-23-191 V-23-193 Procedure EMG-3200.02 Support Proc.

45 Rev.

15 Attachment V Page 3 of 4 the nitrogen supply tank outlet the inlet and outlet valves for HTR-854-166 V-23-365 V-23-366 valive in service by opening he appropriate inlet, outlet V-23-234 V-23-190 V-23-192 V-23-194 3.7 Establish Nitrogen purge flow by completing the following:

3.7.1 Using a wrench, turn the control valve on top of the selected Grove Reducer in the clockwise direction until pressure as indicated on PI-854-1732 is 55 psig.

3.7.2 Verify purge flow on the NITROGEN PURGE & MAKEUP FLOW Recorder (Panel 12XR).

(320002/24)

E22-3

Procedure EMG-3200.02 Support Proc. 45 Rev.

15 Attachment V Page 4 of 4 3.7.3 NOTE Initial temperature could be 20 to 30'F above nominal setpoint of 80 0F.

After 5 to 10 minutes, dependent on ambient temperature, temperature will stabilize.

CAUTION The temperature range of 65 0-95OF as read in the Control Room is important to prevent brittle fracture and cracking of piping within the containment.

Confirm N2 temperature 65-95°F as indicated on the PURGE N2 TEMP gauge (Panel 12XR).

3.7.4 IF ambient temperature is greater than 80°F AND N. temperature is above 95'F as indicated on the PURGE N2 TEMP gauge (Panel 12XR),

THEN secure the nitrogen vaporizer fan by placing the control switch for M-23-001 in OFF position.

3.8 Inform the GOS/GSS that Torus purging has commenced.

3.9 WHEN directed to secure the nitrogen purge, THEN Close Torus purge valves V-23-15 and V-23-16 (Panel 12XR).

(320002/24)

E22-4

Procedure EMG-3200.02 Support Proc.

46 Rev.

15 Attachment W Page 1 of 2 SUPPORT PROCEDURE 46 VENTING THE TORUS FOR HYDROGEN CONTROL 1.0 PREREQUISITES Torus venting has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for venting the Torus via the Reactor Building Ventilation System.

2.1 Confirm Torus water level is below 348 in.

2.2 Evacuate personnel from the Reactor Building.

2.2.1 Sound the Reactor Building Evacuation Alarm.

Time 2.2.2 Make the announcement, "Primary Containment Venting will commence in approximately 5 minutes.

All personnel evacuate the Reactor Building immediately.

Stand clear of the Stack and the Rx.

Bldg.

Fan Pad."

2.3 Select a SGTS Train for operation and place its fan control switch in HAND (Panel 11R).

2.4 Place control switch for V-28-48, SGTS CROSSTIE, in CLOSED (Panel 11R).

2.5 Confirm Reactor Building Supply Fans secured (Panel 11R).

2.6 Confirm Reactor Building Exhaust Fan secured (Panel 11R).

2.7 Confirm that the Reactor Mode Selector switch is NOT in the RUN position (Panel 4F.

2.8 Obtain a bypass plug from the EOP Tool Box in the Control Room.

2.9 CAUTION The containment isolation function of the following valves is bypassed when the High Drywell Pressure and Reactor Low Low Water Level isolation signals are defeated:

"* Drywell Nitrogen Makeup Valves (V-23-17 and V-23-18)

"* Torus Nitrogen Makeup Valves (V-23-19 and V-23-20)

Open the EOP BYPASS PLUGS panel inside Panel 1OXF.

2.9.1 Insert a bypass plug into position BP5.

(320002/25)

E23-1

Procedure EMG-3200.02 Support Proc.

46 Rev.

15 Attachment W Page 2 of 2 2.10 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.10.1 Remove the bypass plug from position BP4.

2.10.2 Insert the bypass plug into position BPI.

2.11 Place the TORUS/DRYWELL ISOLATION VALVE BYPASS PERMISSIVE keylock switch in TORUS position (Panel 11F).

2.12 Place the TORUS/DW VENT AND PURGE ISOL VLVS HI RAD BYPASS keylock switches-.for both Channels 1 and 2.in the BYPASS position (Panel 11F).

2.13 Inform the GSS/GOS that the Torus is ready to be vented via the Torus Vent valves.

3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Reset the Reactor Building Ventilation System by momentarily depressing the system RESET pushbutton (Panel 11R).

3.2 Confirm open Reactor Building Main Exhaust Isolation valves V-28-21 and V-28-22 (Panel 11R).

3.3 WHEN at least five minutes have passed since sounding the Reactor Building Evacuation Alarm, THEN inform the GSS/GOS AND start Reactor Building Exhaust Fan 1-5 (Panel 11R).

3.4 Open Torus Vent valves V-28-18 and V-28-47 (Panel 1iF).

3.5 CAUTION Ventilation Ductwork Failure can occur when venting through V-28-17 with Torus pressure greater than 2 psig.

Open Torus Vent valve V-28-17 (Panel 11F).

3.6 Inform the GSS/GOS that Torus venting via V-28-17, V-28-18 and V-28-47 has commenced.

3.7 IF Containment pressure drops below 0.6 psig THEN

1. Stop Exhaust Fan 1-5 (Panel 11R).
2.

Close Reactor Building Main Exhaust Isolation Valves V-28-21 and V-28-22 (Panel 11R).

(320002/25)

E23-2

Procedure EMG-3200.02 Support Proc. 47 Rev.

15 Attachment X Page 1 of 3 SUPPORT PROCEDURE 47 VENTING THE DRYWELL FOR HYDROGEN CONTROL (LEVEL BELOW 461 IN) 1.0 PREREQUISITES Drywell venting has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for venting the Drywell via the Reactor Building Ventilation System.

2.1 Verify Primary Containment water level is below 461 in.

2.2 Evacuate personnel from the Reactor Building.

2.2.1 Sound the Reactor Building Evacuation Alarm.

Time 2.2.2 Make the announcement, "Primary Containment Venting will commence in approximately five minutes.

All personnel evacuate the Reactor Building immediately.

Stand clear of the Stack and the Rx.

Bldq.

Fan Pad".

2.3 Select a SGTS Train for operation and place its fan control switch in HAND (Panel 11R).

2.4 Place control switch for V-28-48, SGTS CROSSTIE, in CLOSED (Panel 11R).

2.5 Confirm Reactor Building Supply Fans secured (Panel 11R).

2.6 Confirm Reactor Building Exhaust Fan secured (Panel 11R).

2.7 Confirm that the Reactor Mode Selector switch is NOT in RUN (Panel 4F).

2.8 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.8.1 Remove the bypass plug from position BP4.

2.8.2 Insert the bypass plug into position BPI.

(320002/26)

E24-1

Procedure EMG-3200.02 Support Proc.

47 Rev.

15 Attachment X Page 2 of 3 2.9 Place the TORUS/DRYWELL ISOLATION VALVE BYPASS PERMISSIVE Keylock switch in DRYWELL position (Panel 11F).

2.10 Place the TORUS/DW VENT AND PURGE ISOLATION VLVS HI RAD BYPASS CHAN keylock switches for both Channels 1 and 2 in the BYPASS position (Panel 11F).

2.11 CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS Keylock is in the BYPASS position:

"* Drywell Ventilation Isolation Valves (V-27-1, 2,

3 and 4)

"* Torus Nitrogen Purge Inlet Valves (V-23-15 and (V-23-14)

"* Torus Nitrogen Purge Inlet Valves (V-23-15 and (V-23-16)

Place the CNTMT VENT AND PURGE ISOLATION BYPASS Keylock in the BYPASS position (Panel 12XR).

2.12 Inform the GSS/GOS that the Drywell is ready to be vented via the Drywell Vent valves.

3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Reset the Reactor Building Ventilation System by momentarily depressing the system RESET pushbutton (Panel 11R).

3.2 Confirm open Reactor Building Main Exhaust Isolation valves, V-28-21 and V-28-22 (Panel 11R).

3.3 WHEN at least five minutes have passed since sounding the Reactor Building Evacuation Alarm, THEN inform the GSS/GOS, AND start Reactor Building Exhaust Fan 1-5 (Panel 11R) 3.4 Open Drywell Vent valves V-23-21 and V-23-22 (Panel 12XR).

(320002/26)

E24-2

Procedure EMG-3200.02 Support Proc.

47 Rev.

15 Attachment X Page 3 of 3 3.5 CAUTION Ventilation ductwork failure can occur when venting through V-27-1 and V-27-2 with drywell pressure greater than 2 psig.

Confirm Drywell pressure is below 24 psig and open Drywell Vent valves V-27-1 and V-27-2 (Panel 11F).

3.6 Inform the GSS/GOS that Drywell venting via V-23-21, V-23-22, V-27-1 and V-27-2 has commenced.

3.7 IF Containment Pressure drops below 0.6 psig.

THEN

1. Stop Exhaust Fan 1-5 (Panel 1IR).
2.

Close Reactor Building Main Exhaust Isolation Valves V-28-21 and V-28-22 (Panel 11R).

(320002/26)

E24-3

Procedure EMG-3200.02 Support Proc. 48 Rev.

15 Attachment Y Page 1 of 2 SUPPORT PROCEDURE 48 VENTING THE DRYWELL THROUGH THE PURGE SYSTEM FOR HYDROGEN CONTROL 1.0 PREREQUISITES Drywell venting has been directed by the Emergency Operating Procedures.

2.0 PREPARATION Perform the following steps in preparation for venting the Drywell via the Drywell Purge System and Reactor Building Ventilation System.

2.1 Evacuate personnel from the Reactor Building.

2.1.1 Sound the Reactor Building Evacuation Alarm.

Time 2.1.2 Make the announcement, "Primary Containment Venting will commence in approximately five minutes.

All personnel evacuate the Reactor Building immediately.

Stand clear of the Stack and the Rx.

Bldg.

Fan Pad."

2.2 Select a SGTS Train for operation and place its fan control switch in HAND (Panel 11R).

2.3 Place control switch for V-28-48, SGTS CROSSTIE, in CLOSED (Panel 11R).

2.4 Confirm Reactor Building Supply Fans secured (Panel 11R).

2.5 Confirm Reactor Building Exhaust Fan secured (Panel 11R).

2.6 Confirm closed Reactor Building Ventilation Isolation dampers V-28-1 through V-28-16 and V-28-36 through V-28-39 (Panel 11R).

2.7 Open the EOP BYPASS PLUGS panel in the rear of Panel 11R.

2.7.1 Remove the bypass plug from position BP4.

2.7.2 Insert the bypass plug from position BPI.

2.8 CAUTION The containment isolation function of the following valves is bypassed when the CNTMT VENT AND PURGE ISOLATION BYPASS Keylock is in the BYPASS position:

  • Drywell Ventilation Isolation Valves (V-27-1,2,3, and 4)
  • Drywell Nitrogen Purge Inlet Valves (V-23-13 and (V-23-14)
  • Torus Nitrogen Purge Inlet Valves (V-23-15 and (V-23-16)

Place the CNTMT VENT AND PURGE ISOLATION BYPASS Keylock in the BYPASS (Panel 12XR).

(320002/27)

E25-1

Procedure EMG-3200.02 Support Proc.

48 Rev.

15 Attachment Y Page 2 of 2 2.9 Place TORUS/DW VENT AND PURGE ISOL VLVS HI RAD BYPASS keylock switches for both Channels 1 and 2 in BYPASS (Panel 11F).

2.10 Confirm Reactor Building to Torus Vacuum Breakers V-26-16 and V-26-18 control switch in CLOSE position (Panel 11F).

2.11 Inform the GSS/GOS that the Drywell is ready to be vented via the Drywell Purge Valves.

3.0 PROCEDURE When directed by the GSS/GOS, complete the following:

3.1 Reset the Reactor Building Ventilation System by momentarily depressing the system RESET pushbutton (Panel 11R).

3.2 Confirm open Reactor Building Main Exhaust Isolation Valves V-28-21 and V-28-22 (Panel 11R).

3.3 WHEN at least five minutes has passed since sounding the Reactor Building evacuation alarm THEN inform the GSS/GOS, AND start Reactor Building Exhaust Fan 1-5 (Panel 1lR).

3.4 Confirm closed Drywell Air Supply Valves V-28-42 and V-28-43 (Panel 1lR).

3.5 CAUTION Ventilation ductwork failure will occur when venting through V-27-3 and V-27-4 with drywell pressure greater than 2 psig.

Open Drywell Purge Valves V-27-3 and V-27-4 (Panel 11F).

3.6 Inform the GSS/GOS that Drywell Venting has commenced.

3.7 IF Containment pressure drops below 0.6 psig, THEN

1. Stop Exhaust Fan 1-5 (Panel 11R).
2.

Close Reactor Building Main Exhaust Isolation Valves V-28-21 and V-28-22 (Panel 1IR).

(320002/27)

E25-2

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDURE EMG-3200.10 NUCLEAR Title Revision No.

CONTAINMENT FLOODING 8

Applicability/Scope Responsible Office System Engineering EMERGENCY OPERATING PROCEDURE FOR OYSTER CREEK El50 This document is within QA plan scope X Yes No Effective Date Safety Reviews Required X Yes No (04/25/00) 05/05/00 Prior Revision 7

incorporated the This Revision 8

incorporates the following Temporary Changes:

following Temporary Changes:

N/A N/A List Of Pages (all pages rev'd to Rev.

8) 1.0 to 3.0 El-l E2-1 E3-1 to E3-2 E4-1 E5-1 to E5-2 E6-1 to E6-4 E7-1 to E7-4 E8-1 to E8-2 E9-1 to E9-2 OYSTER CREEK CONTROLLED DISTRIBUTION DOCUMENT SERIAL NUMBER IRMC S

Signatue I Concurring Organization Element Date Originator r1A*T A[L&

3 3

T EOP COORDINATOR 6'

OQ

-oP COMMITTEE

MGR, SYSTEMS ENGINEERING/,

_______OPERATIONS DIRECTOR A -

ApprovedON By DIRB R, OPERATIONS & MAINTENANCE Z4e (320010) 1.0

OYSTER CREEK NUCLEAR GENERATING Number (GPU STATION PROCEDURE EMG-3200.10 NUCLEAR Title 1 Revision No.

CONTAINMENT FLOODING8 1.0 PURPOSE The purpose of the Containment Flooding Procedure is to:

Maintain adequate core cooling

2.0 REFERENCES

2.1 Procedures

  • 107.4, EOP Program Control 2.2 Drawings

"* BR 2002, Main, Extraction & Aux Steam System

"* BR 3029, DC Control Elem Diagram

"* BR E1102, Emer Condenser Isol Outlet Valve V-14-35

"* GE 112C2248, Sht 2, Connection Diagram 11F

"* GE 148F262, P&ID - Emergency Condenser System

"* GE 237E566, Sht la lb, 2, 4 & 5, Rx Protection System Elem Diagram 2.3 2000-GLN-3200.01, OC Plant Specific Technical Guidelines 2.4 2000-STD-1218.04, EOP Writer's Guide 3.0 PRECAUTIONS AND LIMITATIONS 3.1 This procedure gives guidance to the operator for bypassing isolation signals and automatic scrams which is a departure from the Oyster Creek Technical Specifications.

It is permissible to take actions which depart from the plant's Technical Specifications during emergency conditions as authorized by 10 CFR 50.54(x).

(320010) 2.0

OYSTER CREEK NUCLEAR GENERATING STATION PROCEDURE NUCLEAR Title Revision No.

CONTAINMENT FLOODING 8

4.0 ATTACHMENTS 4.1 Attachment 4.2 Attachment 4.3 Attachment 4.4 Attachment 4.5 Attachment 4.6 Attachment 4.7 Attachment 4.8 Attachment 4.9 Attachment Containment Flooding EOP Flowchart DWG:

GU 3E-200-08-008 Sh 4 Support Procedure 53, Fire Water Makeup to the CST Support Procedure 54, Demineralized Water Makeup to the CST Support Procedure 55, Transfer of High Purity Waste Sample Tanks to the Hotwell Support Procedure 5, Fire Water Injection Via a Core Spray System Support Procedure 56, One Core Spray System Lined Up with Suction from CST Support Procedure 38, Determining Primary Containment Water Level Support Procedure 57, Opening the MSIVs to Vent the RPV Support Procedure 52, Opening the IC Tube Side Vents to Vent the RPV (320010)

Number EMG-3200.10 3.0

NUCLEAR OYSTER CREEK NUCLEAR GENERATING STATION PROCEDURE Number EMG-3200.10 Title Revision No.

CONTAINMENT FLOODING 8

ATTACHMENT A Attachment A to EMG-3200.10, Containment Flooding, is the Containment Flooding EOP Flowchart, DWG: GU 3E-200-08-008, Sht 4, Rev.

1.

(320010/S3)

E1-1

Procedure EMG-3200.10 Support Proc.

53 Rev.

8 Attachment B Page 1 of 1 SUPPORT PROCEDURE 53 FIRE WATER MAKEUP TO THE CST 1.0 PREREQUISITES Fire Water makeup to the Condensate Storage Tank has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Close the Telltale Drain Valve V-9-11 (Condensate Transfer Bldg).

3.2 Unlock and open the Fire Water Isolation Valve, V-9-9 (Condensate Transfer Bldg).

3.3 Open the Fire Protection to CST Isolation Valve V-11-247 (Condensate Transfer Bldg).

3.4 Confirm both Diesel Fire Pumps are running by placing their control switches in MAN position. (Panel 13R).

(320010/S4)

E2-1 I

Procedure EMG-3200.10 Support Proc.

54 Rev.

8 Attachment C Page 1 of 2 SUPPORT PROCEDURE 54 DEMINERALIZED WATER MAKEUP TO THE CST 1.0 PREREQUISITES Demineralized water makeup to the Condensate Storage Tank has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Open Manual Isolation valves V-12-47 and V-12-49 (Condensate Transfer Bldg).

3.2 Open Flow Control valve V-12-48 (Condensate Transfer Bldg).

3.3 Start all available Demineralized Water Transfer pumps (Panel 13R).

3.4 Open Demineralized Trailer Outlet valve V-10-383.

3.5 Open the Supply Valve to the Carbon Filter V-10-382.

3.6 Place the No.

1 Filter Feed Pump control switch to the ON position (Turbine Building Basement).

3.6.1 Adjust Pump Discharge Valve, V-10-24, as required to maintain inlet pressure at 95 psig +/- 5 psig.

(320010/S5)

E3-1

Procedure EMG-3200.10 Support Proc.

54 Rev.

8 Attachment C Page 2 of 2 3.7 IF the No.

1 Filter Feed Pump does not start, THEN

1. Place the No.

2 Filter Feed Pump control switch to the ON position.

2.

Adjust Pump Discharge valve, V-10-26, as required to maintain inlet pressure at 95 psig

+/- 5 psig.

3.8 Throttle the chain operated Makeup System Outlet valve, V-55-70, as necessary to obtain approximately 75 gpm as read on the Final Effluent Flow Recorder (Turbine Building Basement).

(320010/S5)

E3-2

Procedure EMG-3200.10 Support Proc.

55 Rev.

8 Attachment D Page 1 of 1 SUPPORT PROCEDURE 55 TRANSFER OF HIGH PURITY WASTE SAMPLE TANKS TO THE HOTWELL 1.0 PREREQUISITES Transfer of the High Purity Waste Sample Tanks has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Direct Radwaste to transfer both High Purity Waste Sample Tanks to the Hotwells in accordance with Procedure 351.2, High Purity Waste System.

3.2 Inform Radwaste that no chemistry samples are required for the transfer.

(320010/S6)

E,4-1

Procedure EMG-3200.10 Support Proc. 5 Rev.

8 Attachment E Page 1 of 2 SUPPORT PROCEDURE 5 FIRE WATER FOR RPV WATER LEVEL CONTROL 1.0 PREREQUISITES RPV water level control using Fire Water via the Core Spray System has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 IF Core Spray actuating signals are present, THEN override Core Spray initiation logic by depressing the OVERRIDE switches for all the sensors that are lit and depressing all ACTUATED switches, whether lit or unlit.

3.0 PROCEDURE 3.1 F

IF Core Spray System 1 pumps are not available, THEN inject fire water as follows:

3.1.1 Confirm stopped the.Core Spray Main and Booster Pumps on Core Spray System 1 (Panel 1F/2F).

3.1.2 Place the Core Spray System 1 Main Pump control switches in the PULL-TO-LOCK position (Panel 1F/2F).

3.1.3 Close Tell-Tale Drain Valve, V-20-91 (RB 23 North or North Side RB outside).

3.1.4 Confirm running all Diesel Fire Pumps by placing their control switches in MAN position (Panel 13R).

3.1.5 Open Fire Water Supply Valve, V-20-83 (RB 23 North or North Side RB outside).

3.1.6 Confirm open Core Spray System 1 Discharge Valve, V-20-12 (Panel 1F/2F).

(320010/S7)

E5-1

Procedure EMG-3200.10 Support Proc.

5 Rev.

8 Attachment E Page 2 of 2 3.1.7 Confirm closed Core Spray System 1 Test Flow Return Valve, V-20-27 (Panel IF/2F).

3.1.8 Confirm closed Core Spray System 1 Test Flow Return Valve, V-20-27 (Panel 1F/2F).

3.1.9 Close Core Spray System I1Pump Suction Valves, V-20-32 and V-20-3 (Panel IF/2F).

3.2 NOTE Overriding Core Spray initiation logic may be required.

IF Core Spray System 2 is to be used, THEN inject Fire Water as follows:

3.2.1 Confirm stopped the Core Spray Main and Booster Pumps on Core Spray System 2.

3.2.2 Place the Core Spray System 2 Main Pump control switches in PULL-TO-LOCK position.

3.2.3 Close Tell-Tale Drain Valve V-20-90 (RB 23 South, or South Side RB outside).

3.2.4 Confirm running all Diesel Fire Pumps by placing their control switches in MAN position (Panel 13R).

3.2.5 Open Fire Water Supply Valve, V-20-82 (RB 23 South or South Side RB outside).

3.2.6 Confirm open Core Spray System 2 Discharge Valve, V-20-18 (Panel IF/2F).

3.2.7 Confirm open either Core Spray System 2 Parallel Isolation Valve, V-20-21 or V-20-41 (Panel IF/2F).

3.2.8 Confirm closed Core Spray System 2 Test Flow Return Valve, V-20-26 (Panel IF/2F).

3.2.9 Close Core Spray System 2 Suction Valves, V-20-33 and V-20-4 (Panel IF/2F).

(320010/S7)

E5-2

Procedure EMG-3200.10 Support Proc.

56 Rev.

8 Attachment F Page 1 of 4 SUPPORT PROCEDURE 56 ONE CORE SPRAY SYSTEM LINED UP WITH SUCTION FROM CST 1.0 PREREQUISITES 1.1 Lining up one core spray system for CST Suction has been directed by the Emergency Operating Procedures.

1.2 The Reactor Building and NW Corner Room are accessible.

2.0 PREPARATION 27.1 IF Core Spray actuating signals are present, THEN override Core Spray initiation logic by depressing the OVERRIDE switches for all the sensors that are lit and depressing all ACTUATED switches, whether lit or unlit.

2.2 This procedure requires the use of an MB-I key and access to the Rx.

Bldg.

3.0 PROCEDURE 3.1

--NOTE Overriding Core Spray initiation logic may be required.

IF Core Spray System 1 is designated to be used, THEN complete the following:

3.1.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 1 (Panel 1F/2F).

3.1.2 Place Core Spray System 1 Main Pump control switches in PULL-TO-LOCK position (Panel IF/2F).

3.1.3 Close Core Spray Pump Suction valves V-20-3 and V-20-32 (Panel IF/2F).

(320010/SB)

E6-1

Procedure EMG-3200.10 Support Proc. 56 Rev.

8 Attachment F Page 2 of 4 3.1.4 Place the breakers for Core Spray Pump Suction Valves V-20-3 and V-20-32 in the OFF position.

"* V-20-3 Bkr.

(MCC 1A21A/RB 23 SW)

"* V-20-32 Bkr.

(MCC lB21A/RB 23 NE) 3.1.5 Confirm closed the Test Flow Return Valve V-20-27 (Panel lF/2F).

3.1.6 Unlock and open the following CST supply valves:

"* V-20-1 (NW Corner Room)

"* V-20-5 (NW Corner Room)

"* V-20-34 (NW Corner Room) 3.1.7 CAUTION Diesel Generator overload will result if a Core Spray Main and Booster Pump are started with a Diesel Generator load of greater than 2000 KW.

IF Bus 1C or 1D are being supplied by a Emergency Diesel Generator, THEN verify that adequate load margin is available so as NOT to exceed EDG load limit when starting Core Spray Pumps.

3.1.8 Start Core Spray System 1 Main Pump NZ01A or NZ01C (Panel IF/2F).

3.1.9 Confirm open Core Spray System 1 Discharge Valve V-20-12 (Panel IF/2F).

3.1.10 Confirm open either Core Spray System 1 Parallel Isolation Valve V-20-15 or V-20-40 (Panel IF/2F).

(320010/S8)

E6-2

Procedure EMG-3200.10 Support Proc.

56 Rev.

8 Attachment F Page 3 of 4 3.1.11 Start the Core Spray Booster Pump associated with the running main pump or the other main pump as directed by the GSS/GOS.

3.2 NOTE Overriding Core Spray initiation logic may be required..

IF Core Spray System 2 is designated to be used, THEN complete the following:

3.2.1 Confirm stopped the Core Spray Main and Booster Pumps in Core Spray System 2 (Panel 1F/2F).

3.2.2 Place Core Spray System 2 Main Pump control switches in PULL-TO-LOCK position (Panel 1F/2F).

3.2.3 Close Core Spray Pump Suction valves V-20-4 and V-20-33 (Panel 1F/2F) 3.2.4 Place the breakers for Core Spray Pump Suction Valves V-20-4 and V-20-33 in the OFF position.

"* V-20-4 Bkr (MCC IB21A/RB 23 NE)

"* V-20-33 Bkr (MCC 1A21A/RB 23 SW) 3.2.5 Confirm closed the Test Flow Return Valve V-20-26 (Panel 1F/2F).

3.2.6 Unlock and open the following CST supply valves:

"* V-20-1 (NW Corner Room)

"* V-20-2 (SW Corner Room)

"* V-20-35 (SW Corner Room)

(320010/S8)

E6-3

Procedure EMG-3200.10 Support Proc.

56 Rev.

8 Attachment F Page 4 of 4 3.2.7 CAUTION Diesel Generator overload will result if a Core Spray Main and Booster Pump are started with a Diesel Generator load of greater than 2000 KW.

IF Bus IC or 1D are being supplied by a Emergency Diesel Generator, THEN verify that adequate load margin is available so as NOT to exceed EDG load limit when starting Core Spray Pumps.

3.2.8 Start Core Spray System 1 Main Pump NZ01B or NZ01D (Panel 1F/2F).

3.2.9 Confirm open Core Spray System 2 Discharge Valve V-20-18 (Panel IF/2F).

3.2.10 Confirm open either Core Spray System 2 Parallel Isolation Valve V-20-21 or V-20-41 (Panel IF/2F).

3.2.11 Start the Core Spray Booster Pump associated with the running main pump or the other main pump as directed by the GSS/GOS.

(320010/S8)

E6-4

Procedure EMG-3200.10 Support Proc.

38 Rev.

8 Attachment G Page 1 of 4 SUPPORT PROCEDURE 38 DETERMINING PRIMARY CONTAINMENT WATER LEVEL 1.0 PREREQUISITES 1.1 Determination of Primary Containment Water Level has been directed by the Emergency Operating Procedures.

1.2 Primary Containment Water Level is greater than the range of the wide range Torus level recorder (0-360 inches) on Panel 16R.

2.0 PREPARATION None 3.0 PROCEDURE 3.1 Calculate Primary Containment Water Level by completing the following:

3.1.1 Record Torus pressure from one of the following:

1. Digital indicator on Panel 4F
2.

Computer Point ID PTIP12

3.

PT-IP12 on Panel 1F/2F P(Torus) =

psig 3.1.2 Record Drywell pressure from PI-IP08 on Panel IF/2F P(DW)

=

psig 3.1.3 Calculate AP AP = P(Torus)

P(DW)

=

___psid 3.1.4 IF AP is greater than 16 psid THEN continue at Step 3.2 of this procedure.

3.1.5 Determine Primary Containment Water Level using Figure 38-1.

(320010/S9)

E7-1

Procedure EMG-3200.10 Support Proc.

38 Rev.

8 Attachment G Page 2 of 4 IF Torus -

DW AP is greater than 16 psid, THEN calculate Primary Containment Water Level by completing the following:

3.2.1 Record Torus pressure from one of the following:

1. Digital indicator on Panel 4F
2.

Computer Point ID PTIP12

3.

PT-IP12 on Panel IF/2F P(Torus)

=

psi 3.2.2 Record Drywell pressure from Sample Entry Pressure gauge on H2/02 Panel IT-lB or IT-lA (Reactor Bldg El. 75').

P(H2/02)

-_ psig g

3.2.3 Calculate AP AP = P(Torus)

P(H2/02)

=

psid 3.2.4 Determine Primary Containment Water Level using Figure 38-2.

(320010/S9) 3.2 E7-2

Procedure EMG-3200.10 Support Proc.

38 Rev.

8 Attachment G Page 3 of 4 FIGURE 38-1 CONTAINMENT WATER LEVEL DETERMINATION USING DW PRESSURE INDICATION FROM PANEL 1F/2F 7500 77625 S600...

-- 725 K.;......................

725/

700-675............

4 62*5-> -..-

60 5 5 0................

U-1575 S- --:..............-:

.475-2

4. psid5 46. inch: s). :

4504....4 425 I..7................

3

7.

3T I

i-.

t.
i.

I

350-.........

0 1 2 3 4 5

6 7

8 9 1011 12131415161718 P(Tords)

P(Mw) = psi:d (320010/S9)

E7-3

Procedure EMG-3200.10 Support Proc.

38 Rev.

8 Attachment G Page 4 of 4 FIGURE 38-2 CONTAINMENT WATER LEVEL DETERMINATION USING DW PRESSURE INDICATION FROM THE H2/02 PANELS RB 75' 1300....................

1275 1250.

12.25

psd, 121.2 inches 1 175--.L.--...

~

125 L)1 850.......-......................

LH 0.2 5-

° o

S1000

75.

S 50-L:.I..1....i..[...1..1..I.....I...... I....f....

I 875.

15 16"17 tS 19 20 21 22 23 24 252"6 27 28 29 30 31 32.33 3435 P(T..rU.s)-. P(.:.....2.../.02) p.si (320010/S9)

E7-4

Procedure EMG-3200.10 Support Proc.

57 Rev.

8 Attachment H Page 1 of 2 SUPPORT PROCEDURE 57 OPENING THE MSIVs TO VENT THE RPV 1.0 PREREQUISITES Opening the MSIVs to vent the RPV has been directed by the Emergency Operating Procedures.

2.0 PREPARATION 2.1 Obtain four (4) bypass plugs from the EOP Tool Box in the Control Room.

2.2 Open the EOP BYPASS PLUGS panel in the rear of Panel 6R.

2.2.1 Insert a bypass plug into position BP3.

2.2.2 Insert a bypass plug into position BP4.

2.3 Open the EOP BYPASS PLUGS panel in the rear of Panel 7R.

2.3.1 Insert a bypass plug into position BP3.

2.3.2 Insert a bypass plug into position BP4.

2.4 Reset the MSIV isolation signal by momentarily depressing the MAIN STEAM ISOLATION RESET pushbutton (Panel 4F).

2.5 Confirm the TEST SWITCH V-6-395 is in the NOR position (Panel 11F).

2.6 Open the INSTRUMENT AIR ISOLATION VALVE, V-6-395, by placing its control switch in the OPEN position (Panel 11F).

2.7 Inform GSS/GOS that MSIVs are ready to be opened.

(320010/SI0)

E8-1

Procedure EMG-3200.10 Support Proc.

57 Rev.

8 Attachment H Page 2 of 2 3.0 PROCEDURE When directed by the GSS/GOS, perform the following:

3.1 CAUTION Damage to piping or components downstream of the MSIVs could result if MSIVs are opened with differential pressure greater than 360 psid.

Regardless of the differential pressure open the Main Steam Isolation Valves (Panel 11F).

3.2 Log each operation of the MSIV and the differential pressure across the valves when opened in the CRO Log.

(320010/Si0)

E8-2

Procedure EMG-3200.10 Support Proc.

52 Rev.

8 Attachment I Page 1 of 2 SUPPORT PROCEDURE 52 OPENING IC TUBE SIDE VENTS TO VENT THE RPV 1.0 PREREQUISITES Venting the RPV using the Isolation Condenser Tube Side Vents has been directed by the Emergency Operating Procedures.

2.0 PREPARATION When directed by the GOS/GSS, perform the following, 2.1 Verify the following:

1. Isolation Condensers are not required to be isolated.
2.

Main Condenser is intact.

2.2 Confirm that the Isolation Condenser Vent valve control switches for the Isolation Condenser to be used are in normal mid-position (Panel 11F).

Isolation Condenser A V-14-5 V-14-20 Isolation Condenser-B V-14-1 V-14-19 2.3 Open the EOP BYPASS PLUGS panel inside of Panel 1OXF.

2.3.1 Remove the bypass plug from position BP2 and insert it into position BP1.

2.3.2 Remove the bypass plug from position BP4 and insert it into position BP3.

3.0 PROCEDURE When directed by the GOS/GSS, perform the following:

3.1 Verify that RPV Water Level is less than 180 in TAF.

(320010/SII)

E9-1

Procedure EMG-3200.10 Support Proc.

52 Rev.

8 Attachment I Page 2 of 2 3.2 Confirm open the Isolation Condenser Steam Inlet Valves (IF/2F) for the Isolation Condenser to be used.

Isolation Condenser A V-14-30 V-14-31 Isolation Condenser B V-14-32 V-14-33 3.3 Open the Isolation Condenser tube side vents (Panel 11F) for the Isolation Condenser to be used.

Isolation Condenser A V-14-5 V-14-20 Isolation Condenser B V-14-1 V-14-19 (320010/Sll)

E9-2

OYSTER CREEK NUCLEAR GENERATING Number STATION PROCEDtTr EMG-3200.11 NUCLEAR Title Revision No.

SECONDARY CONTAINMENT CONTROL 10 Applicability/Scope Responsible Office SYSTEMS ENGINEERING (EIC)

EMERGENCY OPERATING PROCEDURE FOR OYSTER CREEK E150 This document is within QA plan scope X Yes No Effective Date Safety Reviews Required X Yes No (04/25/00) 05/05/00 Prior Revision 9

incorporated the This Revision 10 incorporates the following Temporary Changes:

following Temporary Changes:

N/A N/A LIST OF PAGES (all pgs.

rev'd to Rev.

10) 1.0 to 3.0 El-I E2-1 to E2-2 E3-1 Signature Concurring Organization Element Date Originator EOP COORDINATOR Concurred By OCOMTE MANAGER SYSTEMS ENGINEERING (EIC) 1-/1 Ile4(

PLANT OPERATIONS DIRECTOR Approved By CE PRESIDENT & DIRECTOR, OC OYSTER CREEK CONTROLLED DISTRIBUTION (320011) 1.0 DOCUMENT SERIAL NUMBER IRMC

OYSTER CREEK NUCLEAR GENERATING Number GPU STATION PROCEDURE EMG-3200.11 NUCLEAR Title Revision No.

SECONDARY CONTAINMENT CONTROL 10 1.0 PURPOSE The purpose of the Secondary Containment Control Procedure is to:

0 Protect equipment in the Secondary Containment.

2.0 REFERENCES

2.1 Procedures 107.4, EOP Program Control

329, Rx Bldg. Heating and Ventilation System
330, Standby Gas Treatment System 2.2 Drawings BR 3017, 460 VAC MCC Elem Diagram Sht 4 GE 112C2654, Sht 3, Panel 2R Connection Diagram GE 706E841, Vent & Effluent Rad Monitor Elem Diagram GU 3D-822-17-1002, Elem Diagram -

Standby Gas Treatment System SN 15361.03-EC-23, Area Rad. Monitoring Elem Diagram 2.3 2000-GLN-3200.01, OC Plant Specific Technical Guidelines 2.4 2000-STD-1218.04, EOP Writer's Guide 3.0 PRECAUTIONS AND LIMITATIONS 3.1 This procedure gives guidance to the operator for bypassing isolation signals which is a departure from the Oyster Creek Technical Specifications.

It is permissible to take actions which depart from the plant's Technical Specifications during emergency conditions as authorized by 10 CFR 50.54(x).

(320011) 2.0

GU NUCLEAR OYSTER CREEK NUCLEAR GENERATING STATION PROCEDURE Number EMG-3200.11 Title Revision No.

SECONDARY CONTAINMENT CONTROL 10 4.0 ATTACHMENTS 4.1 Attachment A -

Secondary Containment and Radioactivity Release Control EOP Flowchart DWG: GU 3E-200-08-011 Sht 1 4.2 Attachment B -

Support Procedure 49, Confirmation of Secondary Containment Initiations and Isolations 4.3 Attachment C - Support Procedure 50, Reactor Building Ventilation Restart (320011) 3.0

OYSTER CREEK NUCLEAR GENERATING STATION PROCEDURE NUCLEAR Title SECONDARY CONTAINMENT CONTROL T

Number EMG-3200.11 Revision No.

10 ATTACHMENT A Attachment A to EMG-3200.11, Secondary Containment Control, is the Secondary Containment and Radioactivity Release Control EOP Flowchart, DWG:

GU 3E-200-08-011 Sht 1 Rev. 4.

(320011/S3)

EI-I

Procedure EMG-3200.11 Support Proc -

49 Rev.

10 Attachment B Page 1

of 2

SUPPORT PROCEDURE 49 CONFIRMATION OF SECONDARY CONTAINMENT INITIATIONS AND ISOLATIONS 1.0 PREREQUISITES Confirmation of the isolation of Reactor Building Ventilation and initiation of SGTS has been directed by the Emergency Operating Procedures.

2.0 PREPARATION None 3.0 PROCEDURE Confirm the following:

3.1 Both SGTS fans, EF 1-8 and EF 1-9, start (Panel 11R).

3.2 The following Reactor Building Main Supply Header Valves close (Panel 11R).

V-28-1/V-28-2 V-28-3/V-28-4 V-28-5/V-28-6 V-28-7/V-28-8 V-28-9/V-28-10 V-28-11/V-28-12 V-28-13/V-28-14 V-28-15/V-28-16 V-28-36/V-28-37 V-28-38/V-28-39 3.3 Reactor Building Containment Isolation Valves V-28-21 V-28-22 Close (Panel 11R)

(320011/S4)

E2 -1

Procedure EMG-3200.11 Support Proc -

49 Rev.

10 Attachment B Page 2

of 2

3.4 Reactor Building Supply Fans trip (Panel 11R)

SF 1-12 SF 1-13 SF 1-14 3.5 Operating Reactor Building Exhaust Fan trips (Panel 1IR)

EF 1-5 or, EF 1-6 3.6 Drywell Ventilation Supply Valves Close (Panel 11R)

V-28-42 V-28-43 3.7 WHEN proper flow is established in the selected SGTS Train, THEN Confirm the following:

1.

SGTS Crosstie V-28-48 closes (Panel 1IR).

2.

The non-selected SGTS Fan trips (Panel 11R).

3.

The non-selected SGTS Train inlet and discharge valves close (Panel 11R).

4.

The running SGTS Train orifice valve closes (Panel 1IR).

(320011/S4)

E2 -2

Procedure EMG-3200.11 Support Proc -

50 Rev. 10 Attachment C Page 1

of 2

SUPPORT PROCEDURE 50 REACTOR BUILDING VENTILATION RESTART 1.0 PREREQUISITES The restart of Reactor Building Ventilation has been directed by the Emergency Operating Procedures.

2.0 PREPARATION When directed by the GOS/GSS, perform the following:

2.1 Verify that the Reactor Building Ventilation Effluent Monitors (REACTOR BUILDING VENT MANIFOLD NO.

1 AND NO.2) are reading less than 9 mREM/hr (Panel 2R).

2.2 Open the EOP BYPASS PLUGS panel in the rear of Panel l1R.

2.2.1 Remove the bypass plug from Position BP4.

2.2.2 Insert the bypass plug into Position BPl.

3.0 PROCEDURE When directed by the GOS/GSS, perform the following:

3.1 Open the EXH.

VALVES TO MAIN EXHAUST V-28-21 and V-28-22 (Panel 11R).

3.2 Reset the Reactor Building Ventilation System by depressing the RX BLDG.

VENT ISOLATION RESET button (Panel 11R).

3.3 Start REACTOR BUILDING EXHAUST FAN EF 1-5 by placing its control switch in START (Panel 11R).

3.4 Confirm control switch for MAIN SUPPLY HEADER VALVES TO DW V-28-42 and V-28-43 in CLOSE (Panel 11R).

3.5 Select and start two of the following Reactor Bldg Supply Fans, SF 1-12, SF 1-13, and SF 1-14, by placing their control switches in ON (Panel 11R).

(320011/S5)

CAUTION Steps 3.4 and 3.5 should be completed immediately after starting Exhaust Fan EF-1-5 in order to preclude damage to Ventilation System Ducts.

E3 -1