LR-N11-0043, Inservice Inspection Activities - 90 Day Report Sixteenth Refueling Outage

From kanterella
Jump to navigation Jump to search
Inservice Inspection Activities - 90 Day Report Sixteenth Refueling Outage
ML110460111
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 02/03/2011
From: Wagner L
Public Service Enterprise Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LR-N11-0043
Download: ML110460111 (5)


Text

PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 0 PSEG Nuclear LLC 10 CFR 50.55a FEB 0 3 2011 LR-N1 1-0043 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-001 Hope Creek Generating Station Facility Operating License No. NPF-57 Docket No. 50-354 Subject INSERVICE INSPECTION ACTIVITIES- 90 DAY REPORT SIXTEENTH REFUELING OUTAGE This letter submits the ninety (90) day report for Inservice Inspection (ISI) activities conducted at the Hope Creek Generating Station during the sixteenth refueling outage. This report is submitted in accordance with 10 CFR 50.55a(g),Section XI of the ASME Boiler and Pressure Vessel Code (2001 Edition 2003 Addenda and 2001 Edition 2003 Addenda for IWE), and Regulatory Guide 1.147 Acceptable Code Case Number N-532-4.

The Attachments to this letter are as follows:

Attachment 1: Form OAR-i, Owners Activity Report Attachment 2: Table 1 - Items with Flaws or Relevant Conditions That Required Evaluation for Continued Service Attachment 3: Table 2 - Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service (for the period May 4, 2009 to November 11,2010)

There are no regulatory commitments contained in this correspondence.

Should you have any questions regarding this correspondence, please contact Philip J. Duca at 856-339-1640.

Lawrence M. Wagner Plant Manager - Hope Creek Attachments (Three (3) as described above)

SDcI1 95-2168 REV. 7/99

Document Control Desk LR-N1 1-0043 Page 2 cc: Mr. W. Dean, Administrator - Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. R. Ennis, Project Manager Salem and Hope Creek U.S. Nuclear Regulatory Commission One White Flint North Mail Stop 08 B1A 11555 Rockville Pike Rockville, MD 20852 USNRC Senior Resident Inspector - Hope Creek (X24)

P. Mulligan, Manager IV Bureau of Nuclear Engineering PO Box 415 Trenton, NJ 08625 Corporate Commitment Tracking Coordinator (N21)

Hope Creek Commitment Tracking Coordinator (H02)

Document Control Desk LR-N11-0043 Attachment 1 Form OAR-i, Owners Activity Report FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number HCRFO16 Owner PSEG Nuclear LLC, PO Box 236, Hancocks Bridge, NJ 08038 Plant Hope Creek Generating Station Unit No. 1 Commercial Service Date 12/20/86 Refueling Outage No. 16 Current Inspection Interval Third (3rd) {IWE (2nd))

Current Inspection Period Third (1st) {IWE (1st))

Edition and Addenda of Section XI Applicable to the inspection plan 2001 Edition 2003 Addenda; IWE - 2001 Edition, 2003 Addenda; Date and revision of inspection plan 7/2009, Revision 0 / Change 0 Edition & Addenda of Section XI Applicable to repairs and replacements, if different than the inspection plan (Unless specifically identified in the individual repair plan)

CERTIFICATE OF CONFORMANCE I certify that the statements made in this Owner's Activity Report are correct, and that the examinations, tests, repairs, replacements, evaluations, and corrective measures represented by this report conform to the requirements of Section XI.

Certification of Authorization No. N/A Expiration Date N/A Signed 4.*- ' I/ ,:1*. e..sg Date __ I__Z__'_

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New York and employed by Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner's Activity Report, during the period May 4. 2009 to November 11,2010, and state that to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, tests, repairs, replacements, evaluations and corrective measures described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising

-from or connecthdwitthis-inspedtion.

/* ¢ /'. t. Commissions A/L / Z ,1 AM bY 5q2e!

mspe-,r'saignnre r National Board, State, Province, and Endorsements ZO//

Datet/- Zdv-Date!

/-Z6,--Z~

I

Document Control Desk LR-N11-0043 Attachment 2 TABLE 1 - Items with Flaws or Relevant Conditions That Required Evaluation for Continued Service TABLE I - ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Exam Item Item Description Flaw Flaw or Relevant Category Number Characterizati Condition Found on (IWA-3300) During Scheduled

.. -SectionXl Examination or Test (Yes or No) none

Document Control Desk LR-N11-0043 Attachment 3 TABLE 2 - Abstract of Repairs, Replacements or Corrective Measures Required for Continued Service (for the period May 4, 2009 to November 11, 2010)

TABLE 2 - ABSTRACT OF REPAIRS, REPLACEMENTS, OR CORRECTIVE MEASURES REQUIRED FOR CONTINUED SERVICE Code Repair, Item Description Description of Work Flaw or Relevant Date Repair/

Class Replacement, or Condition Found Completed Replacement Corrective During Scheduled Plan Number Measure Section Xl Examination or Test (Yes or No)

.____ _ none .