Letter Sequence Other |
---|
EPID:L-2020-LLE-0127, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report (Approved, Closed) |
|
|
|
---|
Category:Annual Operating Report
MONTHYEARL-2023-122, Corrections to the 2022 Annual Radiological Environmental Operating Report2023-09-20020 September 2023 Corrections to the 2022 Annual Radiological Environmental Operating Report L-2023-108, Report of 10 CFR 50.59 Plant Changes2023-09-11011 September 2023 Report of 10 CFR 50.59 Plant Changes SBK-L-23031, 2022 Annual Radioactive Effluent Release Report2023-04-28028 April 2023 2022 Annual Radioactive Effluent Release Report SBK-L-23044, 2022 Annual Radiological Environmental Operating Report2023-04-28028 April 2023 2022 Annual Radiological Environmental Operating Report L-2022-070, 2021 Annual Radiological Environmental Operating Report2022-05-0303 May 2022 2021 Annual Radiological Environmental Operating Report L-2022-062, Annual Radiological Environmental Operating Report for Calendar Year 20212022-04-13013 April 2022 Annual Radiological Environmental Operating Report for Calendar Year 2021 L-2022-031, Annual Radioactive Effluent Release Report2022-03-0101 March 2022 Annual Radioactive Effluent Release Report NG-21-0011, Submittal of 2020 Annual Radiological Environmental Operating Report2021-05-0404 May 2021 Submittal of 2020 Annual Radiological Environmental Operating Report SBK-L-21045, Submittal of 2020 Annual Radioactive Effluent Release Report2021-04-30030 April 2021 Submittal of 2020 Annual Radioactive Effluent Release Report L-2021-082, Submittal of 2020 Annual Environmental Operating Report2021-04-15015 April 2021 Submittal of 2020 Annual Environmental Operating Report L-2021-066, CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2021-04-14014 April 2021 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications NRC-2021-0010, CFR 50.59 Evaluation and Commitment Change Summary Report2021-04-0202 April 2021 CFR 50.59 Evaluation and Commitment Change Summary Report NG-20-0037, Correction to the 2018 Annual Radiological Environmental Operating Report2020-05-0707 May 2020 Correction to the 2018 Annual Radiological Environmental Operating Report SBK-L-20052, Submittal of 2019 Annual Radioactive Effluent Release Report2020-04-30030 April 2020 Submittal of 2019 Annual Radioactive Effluent Release Report L-2020-044, Report of 10 CFR 50.59 Plant Changes2020-04-20020 April 2020 Report of 10 CFR 50.59 Plant Changes L-2020-068, 2019 Annual Environmental Operating Report2020-04-15015 April 2020 2019 Annual Environmental Operating Report L-2020-041, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2020-04-14014 April 2020 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2020-027, 2019 Annual Operating Report2020-01-12012 January 2020 2019 Annual Operating Report L-2019-044, Report of 10 CFR 50.59 Plant Changes2019-03-27027 March 2019 Report of 10 CFR 50.59 Plant Changes L-2019-057, Cf~ 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2019-03-19019 March 2019 Cf~ 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2019-017, Submittal of 2018 Annual Radioactive Effluent Release Report2019-02-27027 February 2019 Submittal of 2018 Annual Radioactive Effluent Release Report L-2019-039, 2018 Annual Operating Report2019-02-27027 February 2019 2018 Annual Operating Report L-2019-031, Enclosure 3: Turkey Point Units 3 and 4, 2018 Annual Remediation/Restoration Report2018-12-31031 December 2018 Enclosure 3: Turkey Point Units 3 and 4, 2018 Annual Remediation/Restoration Report SBK-L-18071, Submittal of 2017 Annual Radiological Environmental Operating Report2018-04-26026 April 2018 Submittal of 2017 Annual Radiological Environmental Operating Report L-2018-100, Submittal of 10 CFR 50.59(d)(2) Summary Report2018-04-25025 April 2018 Submittal of 10 CFR 50.59(d)(2) Summary Report SBK-L-18077, Submittal of 2017 Annual Environmental Operating Report2018-04-19019 April 2018 Submittal of 2017 Annual Environmental Operating Report L-2018-087, Transmittal of 2017 Annual Environmental Operating Report2018-04-10010 April 2018 Transmittal of 2017 Annual Environmental Operating Report L-2018-063, CFR 50.46 Annual Reporting and 30-day Notification of Changes or Errors in Emergency Core Cooling System Models or Applications2018-03-26026 March 2018 CFR 50.46 Annual Reporting and 30-day Notification of Changes or Errors in Emergency Core Cooling System Models or Applications L-2018-051, 2017 Annual Operating Report2018-02-22022 February 2018 2017 Annual Operating Report NG-17-0124, Submittal of 10 CFR 72.48 Report of Changes, Tests, and Experiments2017-06-28028 June 2017 Submittal of 10 CFR 72.48 Report of Changes, Tests, and Experiments NG-17-0103, Transmittal of 2016 Annual Radiological Environmental Operating Report2017-05-12012 May 2017 Transmittal of 2016 Annual Radiological Environmental Operating Report L-2017-071, Submittal of Report of 10 CFR 50.59 Plant Changes, Tests and Experiments2017-05-0404 May 2017 Submittal of Report of 10 CFR 50.59 Plant Changes, Tests and Experiments L-2017-056, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CPR 50.46 Annual Report2017-03-27027 March 2017 Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CPR 50.46 Annual Report L-2017-030, Submittal of 2016 Annual Report of Reactor Coolant Specific Activity Limits2017-02-28028 February 2017 Submittal of 2016 Annual Report of Reactor Coolant Specific Activity Limits L-2017-029, Submittal of 2016 Annual Radioactive Effluent Release Report2017-02-28028 February 2017 Submittal of 2016 Annual Radioactive Effluent Release Report L-2017-016, Transmittal of 2016 Annual Operating Report2017-02-0707 February 2017 Transmittal of 2016 Annual Operating Report NG-16-0203, 10 CFR 50.46 Annual Report of Changes in Peak Cladding Temperature for the Duane Arnold Energy Center2016-10-12012 October 2016 10 CFR 50.46 Annual Report of Changes in Peak Cladding Temperature for the Duane Arnold Energy Center NG-16-0110, Radiological Environmental Monitoring Program, Annual Report - Part II Data Tabulations and Analyses for the Year 20152016-05-12012 May 2016 Radiological Environmental Monitoring Program, Annual Report - Part II Data Tabulations and Analyses for the Year 2015 ML16138A1732016-05-12012 May 2016 Annual Radiological Environmental Operating Report January 1 to December 31, 2015 NG-16-0110, Duane Arnold - Annual Radiological Environmental Operating Report January 1 to December 31, 20152016-05-12012 May 2016 Duane Arnold - Annual Radiological Environmental Operating Report January 1 to December 31, 2015 SBK-L-16068, Transmittal of 2015 Annual Environmental Operating Report2016-04-28028 April 2016 Transmittal of 2015 Annual Environmental Operating Report L-2016-080, Transmittal of 10 CFR 50.46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - 2015 Annual Report2016-04-0808 April 2016 Transmittal of 10 CFR 50.46, Acceptance Criteria for Emergency Core Cooling Systems in Light Water Nuclear Power Reactors - 2015 Annual Report NRC 2016-0010, Submittal of 10 CFR 50.46 Annual Report2016-03-22022 March 2016 Submittal of 10 CFR 50.46 Annual Report L-2016-049, Annual Operating Report for St. Lucie 1 and 2, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors2016-03-0202 March 2016 Annual Operating Report for St. Lucie 1 and 2, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors NG-15-0293, Submittal of 10 CFR 50.46 Annual Report of Chanqes in Peak Claddinq Temperature2015-09-23023 September 2015 Submittal of 10 CFR 50.46 Annual Report of Chanqes in Peak Claddinq Temperature SBK-L-15140, Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2015-07-0909 July 2015 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications NG-15-0121, 2014 Annual Radioactive Material Release Report2015-04-30030 April 2015 2014 Annual Radioactive Material Release Report SBK-L-15090, 2014 Annual Environmental Operating Report2015-04-30030 April 2015 2014 Annual Environmental Operating Report SBK-L-15086, 2014 Annual Radiological Environmental Operating Report2015-04-23023 April 2015 2014 Annual Radiological Environmental Operating Report NRC 2015-0021, 10 CFR 50.46 Annual Report for 20142015-04-14014 April 2015 10 CFR 50.46 Annual Report for 2014 2023-09-20
[Table view] Category:Letter type:L
MONTHYEARL-2024-001, Relief Request CISl-03-01 for Relief Concerning Containment Unbonded Post-Tensioning System Inservice Inspection Requirements2024-01-26026 January 2024 Relief Request CISl-03-01 for Relief Concerning Containment Unbonded Post-Tensioning System Inservice Inspection Requirements L-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2024-004, Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years2024-01-18018 January 2024 Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years L-2024-007, Inservice Inspection Program Owner'S Activity Report (OAR-1)2024-01-18018 January 2024 Inservice Inspection Program Owner'S Activity Report (OAR-1) L-2024-003, NextEra Energy Seabrook, LLC - 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report2024-01-11011 January 2024 NextEra Energy Seabrook, LLC - 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report L-2024-002, Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2024-01-0808 January 2024 Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-173, Quality Assurance Topical Report (FPL-1) Revision 30 Update2023-12-15015 December 2023 Quality Assurance Topical Report (FPL-1) Revision 30 Update L-2023-179, Unusual or Important Environmental Event - Turtle Mortality2023-12-14014 December 2023 Unusual or Important Environmental Event - Turtle Mortality L-2023-180, Submittal of Changes to the Technical Specification Bases2023-12-13013 December 2023 Submittal of Changes to the Technical Specification Bases L-2023-174, Subsequent License Renewal Application - Third Annual Update2023-12-13013 December 2023 Subsequent License Renewal Application - Third Annual Update L-2023-168, License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 52023-12-12012 December 2023 License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 5 L-2023-166, Turkey Points Units 3 and 4, Correction to the 2022 Annual Radioactive Effluent Release Report2023-12-0606 December 2023 Turkey Points Units 3 and 4, Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-172, Supplement to Exemption Request Regarding Enhanced Weapons. Firearms Background Checks. and Security Event Notifications Final Rule2023-11-29029 November 2023 Supplement to Exemption Request Regarding Enhanced Weapons. Firearms Background Checks. and Security Event Notifications Final Rule L-2023-177, Supplement to Seabrook Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-11-29029 November 2023 Supplement to Seabrook Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule L-2023-176, Supplement to Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-11-29029 November 2023 Supplement to Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule L-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-162, Response to 50.69 2nd Round of Rals2023-11-21021 November 2023 Response to 50.69 2nd Round of Rals L-2023-160, Part 73 Exemption Request Regarding Enhanced Weapons, Firearms, Background Checks, and Security Event Notifications Final Rule2023-11-16016 November 2023 Part 73 Exemption Request Regarding Enhanced Weapons, Firearms, Background Checks, and Security Event Notifications Final Rule L-2023-159, Part 3 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks and Security Event Notifications Final Rule2023-11-16016 November 2023 Part 3 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks and Security Event Notifications Final Rule L-2023-146, Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule2023-11-16016 November 2023 Part 73 Exemption Request Regarding Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Final Rule L-2023-078, License Amendment Request 278, Incorporate Advanced Fuel Products, Extend Surveillance Intervals and 10 CFR 50.46 Exemption Request to Facilitate Transition to 24-Month Fuel Cycles2023-11-15015 November 2023 License Amendment Request 278, Incorporate Advanced Fuel Products, Extend Surveillance Intervals and 10 CFR 50.46 Exemption Request to Facilitate Transition to 24-Month Fuel Cycles L-2023-077, License Amendment Request 277 Updated Spent Fuel Pool Criticality Analysis2023-10-11011 October 2023 License Amendment Request 277 Updated Spent Fuel Pool Criticality Analysis L-2023-131, Subsequent License Renewal Application - Second Annual Update2023-09-28028 September 2023 Subsequent License Renewal Application - Second Annual Update L-2023-136, Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-26026 September 2023 Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-122, Corrections to the 2022 Annual Radiological Environmental Operating Report2023-09-20020 September 2023 Corrections to the 2022 Annual Radiological Environmental Operating Report L-2023-128, License Amendment Request to Revise TS 5.5.17, Pre-Stressed Concrete Containment Tendon Surveillance Program2023-09-19019 September 2023 License Amendment Request to Revise TS 5.5.17, Pre-Stressed Concrete Containment Tendon Surveillance Program L-2023-127, Correction to the 2022 Annual Radioactive Effluent Release Report2023-09-18018 September 2023 Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-113, Correction to the 2020 Annual Radiological Environmental Operating Report2023-09-14014 September 2023 Correction to the 2020 Annual Radiological Environmental Operating Report L-2023-108, Report of 10 CFR 50.59 Plant Changes2023-09-11011 September 2023 Report of 10 CFR 50.59 Plant Changes L-2023-118, Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-11011 September 2023 Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-107, Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.42023-09-0606 September 2023 Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.4 L-2023-112, Corrections to the 2021 Annual Radioactive Effluent Release Report2023-09-0606 September 2023 Corrections to the 2021 Annual Radioactive Effluent Release Report L-2023-110, Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project2023-08-25025 August 2023 Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2023-115, Inservice Inspection Program Owner'S Activity Report (OAR-1)2023-08-21021 August 2023 Inservice Inspection Program Owner'S Activity Report (OAR-1) L-2023-114, Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update2023-08-17017 August 2023 Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-104, Preparation and Scheduling of Operator Licensing Examinations2023-08-0303 August 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-103, Inservice Inspection Examination Report2023-08-0303 August 2023 Inservice Inspection Examination Report L-2023-105, Preparation and Scheduling of Operator Licensing Examinations2023-08-0303 August 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-094, Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project2023-07-27027 July 2023 Response to Requests for Additional Information Regarding License Amendment Request No. 276, Revise Fire Protection Program in Support of Reactor Coolant Pump Seal Replacement Project L-2023-099, Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2023-07-26026 July 2023 Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-102, Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches2023-07-26026 July 2023 Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches L-2023-089, Refueling Outage Owner'S Activity Report (OAR-1) Unit 2 for Inservice Inspections2023-07-24024 July 2023 Refueling Outage Owner'S Activity Report (OAR-1) Unit 2 for Inservice Inspections L-2023-097, Subsequent License Renewal Application Revision 1 - Supplement 62023-07-13013 July 2023 Subsequent License Renewal Application Revision 1 - Supplement 6 L-2023-076, In-Service Inspection Program Owner'S Activity Report (OAR-1)2023-07-11011 July 2023 In-Service Inspection Program Owner'S Activity Report (OAR-1) L-2023-087, Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452)2023-06-29029 June 2023 Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452) L-2023-086, Request Temporary Suspension of Turkey Point License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation.2023-06-28028 June 2023 Request Temporary Suspension of Turkey Point License Amendment Request 274, Reactor Protection System, Engineered Safety Features Actuation System, and Nuclear Instrumentation. L-2023-088, 10 CFR 50.55a Requests, Relief Requests I6-RR-1, I6-RR-2, and I6-RR-3 Sixth Ten-Year Inservice Inspection Program Interval2023-06-27027 June 2023 10 CFR 50.55a Requests, Relief Requests I6-RR-1, I6-RR-2, and I6-RR-3 Sixth Ten-Year Inservice Inspection Program Interval L-2023-082, Subsequent License Renewal Application Revision 1, Supplement 52023-06-14014 June 2023 Subsequent License Renewal Application Revision 1, Supplement 5 L-2023-075, Response to Request for Additional Information (RAI) Regarding Exemption Request, License Amendment Request and Revised Response in Support of a Risk-Informed Resolution of Generic Letter 2004-022023-06-0909 June 2023 Response to Request for Additional Information (RAI) Regarding Exemption Request, License Amendment Request and Revised Response in Support of a Risk-Informed Resolution of Generic Letter 2004-02 2024-01-08
[Table view] |
Text
April 14, 2020 L-2020-041 10 CFR 50.46 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555 Re: Florida Power & Light Company Turkey Point Units 3 and 4, Docket Nos. 50-250, 50-251 Florida Power & Light Company St. Lucie Units 1 and 2, Docket Nos. 50-335, 50-389 NextEra Energy Seabrook, LLC Seabrook Station, Docket No. 50-443 NextEra Energy Duane Arnold, LLC Duane Arnold Energy Center, Docket No. 50-331 NextEra Energy Point Beach, LLC Point Beach Units 1 and 2, Docket Nos. 50-266, 50-301 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications Pursuant to 10 CFR 50.46(a)(3)(ii), the nature of any change to or error discovered in the evaluation models for emergency core cooling systems (ECCS), or in the application of such models, that affect the fuel cladding temperature calculations for Florida Power & Lights Turkey Point Nuclear Plant, Units 3 and 4; and St. Lucie Nuclear Plant, Units 1 and 2; NextEra Energy Seabrook Station; NextEra Energy Duane Arnold; and NextEra Energy Point Beach Nuclear Plant, Units 1 and 2 are reported in the attachments to this letter. The data interval for this report is from January 1, 2019 through December 31, 2019.
Evaluations of each reported error have concluded that re-analysis was not required.
This letter contains no new or revised regulatory commitments.
Florida Power & Light Company 700 Universe Boulevard, Juno Beach, FL 33408
Should you have any questions regarding this report, please contact Mr. Steve Catron, Fleet Licensing Manager, at (561) 304-6206.
- ~
William L. Parks General Manager, Safety Assurance and Learning Florida Power & Light Company Attachments (5) cc: USNRC Regional Administrator, Region I USNRC Regional Administrator, Region II USNRC Regional Administrator, Region III USNRC Project Manager, Seabrook Station USNRC Project Manager, St. Lucie Nuclear Plant USNRC Project Manager, Turkey Point Nuclear Plant USNRC Project Manager, Duane Arnold Energy Center USNRC Project Manager, Point Beach Nuclear Plant USNRC Senior Resident Inspector, Seabrook Station USNRC Senior Resident Inspector, St. Lucie Nuclear Plant USNRC Senior Resident Inspector, Turkey Point Nuclear Plant USNRC Senior Resident Inspector, Duane Arnold Energy Center USNRC Senior Resident Inspector, Point Beach Nuclear Plant I
L
ATTACHMENT 1 Florida Power & Light Company Turkey Point Units 3 and 4
L-2020-041 Page l 1 of 2 Table 1:
Turkey Point Unit 3 & 4 Small Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Westinghouse, Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code,"
WCAP-10054-P-A, August 1985 and Addendum 2, Revision 1, July 1997.
Evaluation Model PCT: 1231 °F (Reference 1)
Net PCT Absolute PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to 0 °F 0 °F 12/31/2018 (Reference 2) 10 CFR 50.46 Changes or Errors Corrections - year 2019 UO2 Fuel Pellet Heat Capacity Error 0 °F 0 °F Sum of 10 CFR 50.46 Changes or Errors Corrections 0 °F 0 °F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact 1231 °F < 2200 °F for changes and errors identified since this analysis UO2 Fuel Pellet Heat Capacity An error was discovered in the UO2 fuel pellet heat capacity described by Equation C-4 of WCAP-8301 for fuel rod heat-up calculations within the Appendix K Small Break LOCA evaluation model. The erroneous formulation results in an over-prediction of heat capacity that increases with fuel temperature.
The corrected formulation results in a maximum decrease in heat capacity on the order of approximately 1.2% for existing analyses of record.
References:
- 1. Letter from M. Kiley to U.S. Nuclear Regulatory Commission, License Amendment Request for Expended Power Uprate (LAR 205), L-2010-113, October 21, 2010.
- 2. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, L-2019-057, March 19, 2019.
L-2020-041 Page l 2 of 2 Table 2:
Turkey Point Unit 3 & 4 Large Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Westinghouse, Realistic Large-Break LOCA Evaluation Methodology Using the Automated Statistical Treatment Of Uncertainty Method (ASTRUM), WCAP-16009-P-A, Revision 0, January 2005.
Evaluation Model PCT: 2152 °F (Reference 1)
Net PCT Absolute PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to
-28 °F 80 °F 12/31/2018 (Reference 2) 10 CFR 50.46 Changes or Errors Corrections - year 2019 Error in Vapor Temperature Resetting Logic 0 °F 0 °F (Reference 3)
Error in the Implementation of the Vessel 0 °F 0 °F Interfacial Heat Transfer Limit (Reference 4)
Sum of 10 CFR 50.46 Changes or Errors Corrections -28 °F 80 °F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact 2124 °F < 2200 °F for changes and errors identified since this analysis
References:
- 1. Letter from M. Kiley to U.S. Nuclear Regulatory Commission, Response to NRC Reactor Systems Branch Request for Additional Information Regarding Extended Power Uprate License Amendment Request No. 205 and Thermal Conductivity Degradation, L-2012-019, January 16, 2012.
- 2. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, L-2019-057, March 19, 2019.
- 3. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report, L-2019-058, March 25, 2019.
- 4. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report, L-2019-151, August 6, 2019.
ATTACHMENT 2 Florida Power & Light Company St. Lucie Units 1 and 2
L-2020-041 Page l 1 of 4 Table 1:
St. Lucie Unit 1 Small Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Framatome, PWR Small Break LOCA Evaluation Model, S-RELAP5 Based, EMF-2328(P)(A)
Revision 0 as supplemented by ANP-3000(P), Revision 0.
Evaluation Model PCT: 1828°F Net PCT Absolute PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to
+24 °F 84 °F Year 2018 (Reference 1) 10 CFR 50.46 Changes or Error Corrections - Year 2019 None None Sum of 10 CFR 50.46 Changes or Error Corrections +24 °F 84 °F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT 1852 F < 2200 F impact for changes and errors identified since this analysis
References:
- 1. Letter L-2019-057, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, 3/19/19 (ML19080A058).
L-2020-041 Page l 2 of 4 Table 2:
St. Lucie Unit 1 Large Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Framatome, Realistic Large Break LOCA Methodology for Pressurized Water Reactors, EMF-2103(P)(A) Revision 0 as supplemented by ANP-2903(P), Revision 1.
Evaluation Model PCT: 1788°F Absolute PCT Net PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to
+6 °F 6°F Year 2018 (Reference 1) 10 CFR 50.46 Changes or Error Corrections - Year 2019 Error in Cathcart-Pawel correlation 0 °F 0 °F implementation for Zirconium Metal Reacted Sum of 10 CFR 50.46 Changes or Error Corrections +6 °F 6°F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT 1794 F < 2200 F impact for changes and errors identified since this analysis Error in Cathcart-Pawel Correlation Implementation In the RLBLOCA methodology, the correlation for the rate of oxide thickness was used instead of the correlation for the rate of total oxygen consumed, which is the correct correlation to be used in the follow-on calculations in S-RELAP5. The correction of this error resulted in negligible impact on the RLBLOCA PCT (0°F).
References:
- 1. Letter L-2019-057, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, 3/19/19 (ML19080A058).
L-2020-041 Page l 3 of 4 Table 3:
St. Lucie Unit 2 Small Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Framatome, PWR Small Break LOCA Evaluation Model, S-RELAP5 Based, EMF-2328(P)(A)
Revision.0.
Evaluation Model PCT: 2057°F Absolute PCT Net PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to
-279°F 393 °F Year 2018 (Reference 1) 10 CFR 50.46 Changes or Error Corrections - Year 2019 None None Sum of 10 CFR 50.46 Changes or Error Corrections -279°F 393 °F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT 1778 °F < 2200 °F impact for changes and errors identified since this analysis
References:
- 1. Letter L-2019-057, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, 3/19/19 (ML19080A058).
L-2020-041 Page l 4 of 4 Table 4:
St. Lucie Unit 2 Large Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Framatome, Realistic Large Break LOCA Methodology for Pressurized Water Reactors, EMF-2103(P)(A) Revision 0.
Evaluation Model PCT: 1732°F Absolute PCT Net PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to 0 °F 0 °F Year 2018 (Reference 1) 10 CFR 50.46 Changes or Error Corrections - Year 2019 Error in Cathcart-Pawel correlation 0 °F 0 °F implementation for Zirconium Metal Reacted Sum of 10 CFR 50.46 Changes or Error Corrections 0 °F 0 °F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT 1732 °F < 2200 °F impact for changes and errors identified since this analysis Error in Cathcart-Pawel Correlation Implementation In the RLBLOCA methodology, the correlation for the rate of oxide thickness was used instead of the correlation for the rate of total oxygen consumed, which is the correct correlation to be used in the follow-on calculations in S-RELAP5. The correction of this error resulted in negligible impact on the RLBLOCA PCT (0°F).
References:
- 1. Letter L-2019-057, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, 3/19/19 (ML19080A058).
ATTACHMENT 3 NextEra Energy Seabrook Station
L-2020-041 Page l 1 of 2 Table 1:
Seabrook Unit 1 Small Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Westinghouse, Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code,"
WCAP-10054-P-A, August 1985 and Addendum 2, Revision 1, July 1997.
Evaluation Model PCT: 1373 °F (Reference 1)
Net PCT Absolute PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to 0 °F 00 °F 12/31/2018 (Reference 2) 10 CFR 50.46 Changes or Errors Corrections - year 2019 UO2 Fuel Pellet Heat Capacity Error 0 °F 0 °F Sum of 10 CFR 50.46 Changes or Errors Corrections 0 °F 0 °F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact 1373 °F < 2200 °F for changes and errors identified since this analysis UO2 Fuel Pellet Heat Capacity An error was discovered in the UO2 fuel pellet heat capacity described by Equation C-4 of WCAP-8301 for fuel rod heat-up calculations within the Appendix K Small Break LOCA evaluation model. The erroneous formulation results in an over-prediction of heat capacity that increases with fuel temperature.
The corrected formulation results in a maximum decrease in heat capacity on the order of approximately 1.2% for existing analyses of record.
References:
- 1. Letter from M. Warner to U.S. Nuclear Regulatory Commission, License Amendment Request 04-03, Application for Stretch Power Uprate, NYN-04016, March 17, 2004.
- 2. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, L-2019-057, March 19, 2019.
L-2020-041 Page l 2 of 2 Table 2:
Seabrook Unit 1 Large Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Westinghouse, Code Qualification Document for Best Estimate LOCA Analysis, WCAP-12945-P-A, March 1998.
Evaluation Model PCT: 1784 °F (Reference 1)
Net PCT Absolute PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to 155 °F 155 °F 12/31/2018 (Reference 2) 10 CFR 50.46 Changes or Errors Corrections - year 2019 Error in Vapor Temperature Resetting Logic 0 °F 0 °F (Reference 3)
Error in the Implementation of the Vessel 0 °F 0 °F Interfacial Heat Transfer Limit (Reference 4)
Error in the Core Barrel Wetted Perimeter 0 °F 0 °F (Reference 5)
Sum of 10 CFR 50.46 Changes or Errors Corrections 155 °F 155 °F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact 1939 °F < 2200 °F for changes and errors identified since this analysis
References:
- 1. Letter from M. Warner to U.S. Nuclear Regulatory Commission, License Amendment Request 04-03, Application for Stretch Power Uprate, NYN-04016, March 17, 2004.
- 2. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, L-2019-057, March 19, 2019.
- 3. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report, L-2019-058, March 25, 2019.
- 4. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report, L-2019-151, August 6, 2019.
- 5. Letter from W. Parks to U.S. Nuclear Regulatory Commission, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report, L-2019-179, September 26, 2019.
ATTACHMENT 4 NextEra Energy Duane Arnold
L-2020-041 Page l 1 of 1 Table 1:
Duane Arnold GNF2 LOCA PCT 2019 Annual Report Evaluation Methodology:
General Electric, The GESTR-LOCA and SAFER Models for the Evaluation of the Loss-of Coolant Accident: Volume III - SAFER/GESTR Application Methodology, NEDE-23785-1-PA, February 1985.
Global Nuclear Fuel, Licensing Topical Report, The PRIME Model for Analysis of Fuel Rod Thermal-Mechanical Performance, Technical Bases - NEDC-33256P-A, Qualification - NEDC-33257P-A, and Application Methodology - NEDC-33258P-A, September 2010.
General Electric-Hitachi, Duane Arnold Energy Center GNF2 ECCS-LOCA Evaluation, Engineering Report #0000-0133-6901-R0, DRF 0000-0133-6885-R0, August 2012.
Evaluation Model PCT: 1730 °F Net PCT Absolute Effect PCT Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to 12/31/2018
-10 °F 70 °F (Reference 1) 10 CFR 50.46 Changes or Error Corrections - 2019 SAFER Lower Limit on Differential Pressure for 0 °F 0 °F Bypass Leakage (Reference 2)
Sum of 10 CFR 50.46 Changes or Errors Corrections -10 °F 70 °F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT impact for changes and 1720 °F < 2200 °F errors identified since this analysis
References:
- 1. Letter from W. Parks (Florida Power & Light Company) to USNRC, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, L-2019-057, March 19, 2019.
- 2. Letter from W. Parks (Florida Power & Light Company) to USNRC, 10 CFR 50.46 - Emergency Core Cooling System LOCA 30-Day Report, L-2019-202, November 19, 2019.
ATTACHMENT 5 NextEra Energy Point Beach Units 1 and 2
L-2020-041 Page l 1 of 2 Table 1:
Point Beach Units 1 and 2 Small Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Westinghouse, Westinghouse Small Break ECCS Evaluation Model Using the NOTRUMP Code,"
WCAP-10054-P-A, August 1985 and Addendum 2, Revision 1, July 1997.
Evaluation Model PCT (Unit 1/Unit 2): 1049°F/1103°F Net PCT Absolute PCT Effect Effect Prior 10 CFR 50.46 Changes or Error Corrections - up to 0°F/0°F 0°F/0°F Year 2018 (Reference 1) 10 CFR 50.46 Changes or Error Corrections - Year 2019 Error in implementation of UO2 fuel pellet heat 0°F/0°F 0°F/0°F capacity Sum of 10 CFR 50.46 Changes or Error Corrections 0°F/0°F 0°F/0°F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT 1049F/1103°F < 2200 F impact for changes and errors identified since this analysis Error in Implementation of UO2 Fuel Pellet Heat Capacity An error was discovered in the implementation of the UO2 fuel pellet heat capacity described in Equation C-4 of WCAP-8301 for fuel rod heat-up calculations within the Appendix K Small Break LOCA evaluation model. The erroneous formulation results in an over-prediction of heat capacity that increases with fuel temperature. Small over-prediction in UO2 fuel pellet heat capacity has been evaluated to have a negligible effect on small break LOCA analysis results leading to an estimated PCT impact of 0°F.
References:
- 1. Letter L-2019-057, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications, 3/19/2019 (ML19080A058).
L-2020-041 Page l 2 of 2 Table 2:
Point Beach Units 1 and 2 Large Break LOCA PCT 2019 Annual Report Evaluation Methodology:
Westinghouse, "Realistic Large-Break LOCA Evaluation Methodology Using the Automated Statistical Treatment of Uncertainty Method (ASTRUM)," WCAP-16009-P-A, January 2005.
Westinghouse, Application of Best Estimate Large Break LOCA Methodology to Westinghouse PWRs with Upper Plenum Injection," WCAP-14449-P-A Revision 1, October 1999.
Evaluation Model PCT (Unit 1/Unit 2): 1975°F/1810°F Net PCT Effect Absolute PCT Effect Unit 1/Unit 2 Unit 1/Unit 2 Prior 10 CFR 50.46 Changes or Error Corrections - up to
+210°F/+248°F 210°F/340°F Year 2018 (Reference 1) 10 CFR 50.46 Changes or Error Corrections - Year 2019 Error in Vapor Temperature Resetting Logic 0°F/0°F 0°F/0°F (Reference 2)
Error in the Implementation of the Vessel 0°F/0°F 0°F/0°F Interfacial Heat Transfer Limit (Reference 3)
Sum of 10 CFR 50.46 Changes or Error Corrections +210°F/+248°F 210°F/340°F The sum of the PCT from the most recent analysis using an acceptable evaluation model and the estimates of PCT 2185F/2058°F < 2200 F impact for changes and errors identified since this analysis
References:
- 1. Letter L-2019-057, 10 CFR 50.46 Annual Reporting of changes to, or Errors in Emergency Core Cooling System Models or Applications, 3/19/2019 (ML19080A058).
- 2. Letter L-2019-058, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report, 3/25/2019 (ML19087A118).
- 3. Letter L-2019-151, 10 CFR 50.46 - Emergency Core Cooling System LBLOCA 30-Day Report, 8/6/2019 (ML19220A049).