VAR 2 5 2008 L-2008-058 FPL IOCFR50, Appendix E US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC, 20555 Gentlemen, Re:

Turkey Point Unit 4 Docket Nos. 50-251 Emergency Response Data System (ERDS) Maintenance This letter is being submitted pursuant to 10CFR50, Appendix E, VI, 3.b (Maintaining the Emergency Response Data System) for Turkey Point Unit 4 (TP4) due to ERDS Point ID revisions.

Turkey Point Unit 4 (TP4) will be undergoing a major modification (i.e., replacement) of the Emergency Response Data Acquisition and Display System (ERDADS) during the spring, 2008 Refueling Outage. The ERDADS is the plant computer system that supplies the ERDS data points (as described in NUREG-1394, Revision 1).

The TP4 ERDS Data Point Library (DPL) will retain all the original data points (i.e., 59 data points) but will revise the Point IDs to a format that has been established for the new Distributed Control System (DCS) configured ERDADS (see Attachments 1 & 2). This Point ID change will affect the ERDS transmission format and computer communication protocol, therefore NRC notification is required 30 days prior to implementation. This will require ERDS DPL point ID updates for TP4 by NRC personnel.

Associated "detail" data for several of the points has also been updated to reflect current plant configuration as well as enhancements gained from DCS display capabilities. This too will require ERDS DPL updates for TP4 by NRC personnel.

PTN will coordinate the ERDS Point ID change-over and testing with the NRC Operations Center following installation and verification of the new DCS ERDS points.

This is anticipated to be towards the end of April, 2008 and prior to TP4 resuming plant operation following the outage.

Current scheduling for outage work on the ERDADS (and ERDS) is from April 1 st, 2008 through May 2nd 2008. This activity will be separately communicated to the NRC just prior to the plant outage in accordance with 10CFR50.72 (b) (3) (xiii) and will include notification of the NRC resident inspector and any follow up notifications as may be required.

,4c2z an FPL Group company I

This information is being provided for both compliance to 0OCFR50, Appendix E, VI, 3.a and 3'b requirements and to support implementation by the NRC of the new TP4 ERDS Data Point IDs.

Should there be any questions, please contact Paul Infanger, Licensing Manager, at 305-246-6632.

WilliamCJeffersoni, Jr.

Vice President Turkey Point Nuclear Plant Attachments cc:

Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant USNRC Project Manager, Turkey Point

/

ATTACHMENT 1 TP4 ERDS Data Parameter Point IDs Item #

Old Point ID New DCS Point ID Description 1

NIAVPRLVL-4 NIAVPRL V POWER RANGE POWER LEVEL (AVG) 2 INTERMEDIATE RANGE POWER LVL NIAVIRLVL-4 NIAVIRL V(AG (AVG) 3 NIAVSRLVL-4 NIAVSRL V SOURCE RANGE POWER LVL (AVG) 4 NI6649AVPR-4 N6649AVPV GAMMA-METRICS AVE OF PR (AVG) 5 NI6649AVSR-4 N6649AVSV GAMMA-METRICS AVE OF SR (AVG) 6 RXHDLVLLO-4 RXHDLLO V REACTOR HEAD LEVEL (AUCT LOW) 7 RXPLLVLLO-4 RXPLLLO V REACTOR PLENUM LEVEL (AUCT P VLOW) 8 CET-4 CETV CORE EXIT TEMP (AUCT HIGH) 9 SCMCETLO-4 SCMCETLO V SUBCOOLING (AUCT LOW) 10 RCSA-AVFLO-4 RCSA AVF V RCS A AVERAGE FLOW 11 RCSB-AVFLO-4 RCSB AVF V RCS B AVERAGE FLOW 12 RCSC-AVFLO-4 RCSC AVF V RCS C AVERAGE FLOW 13 SGA-AVLVL-4 SGA AVL V STEAM GENERATOR LEVEL A (AVG) 14 LT477-4 L477 A STM GEN A WIDE RANGE LEVEL 15 SGB-AVLVL-4 SGB AVL V STEAM GENERATOR LEVEL B (AVG) 16 LT487-4 L487 A STM GEN B WIDE RANGE LEVEL 17 SGC-AVLVL-4 SGC AVL V STEAM GENERATOR LEVEL C (AVG) 18 LT497-4 L497 A STM GEN C WIDE RANGE LEVEL 19 STEAM GENERATOR PRESSURE A SGA-AVPRES-4 SGAAVPV (AVG) 20 SGB-AVPRES-4 SGBAVPV STEAM GENERATOR PRESSURE B (AVG) 21 STEAM GENERATOR PRESSURE C SGC-AVPRES-4 SGC AVP V (AVG) 22 SGAAVFWFLO-4 SGAAVFWF-V FEEDWATER FLOW A SG (AVG) 23 SGBAVFWFLO-4 SGBAVFWF V FEEDWATER FLOW B SG (AVG) 24 SGCAVFWFLO-4 SGCAVFWF V FEEDWATER FLOW C SG (AVG) 25 SGCAVFWFLO-4 SGCAVFWFV AU FEEDWATER FLOW A

SG (AVG 25 AUX FEEDWATER FLOW A SG U3 SGAAFWFLO-4 SGAAFWIF_

(TTL (TOTAL) 26 AUX FEEDWATER FLOW B SG U3 SGBAFWFLO-4 SGBAFWF_

(TTV (TOTAL) 27 AUX FEEDWATER FLOW C SG U3 SGCAFWFLO-4 SGCAFWF_

(TTV (TOTAL)

RCS HOT LEG A AVG TEMP 28 THA-AVTEMP-4 THAAVTPV 29 THB-AVTEMP-4 THB AVTP V RCS HOT LEG B AVG TEMP 30 THC-AVTEMP-4 THC AVTP V RCS HOT LEG C AVG TEMP

TP4 ERDS Data Parameter Point IDs (cont'd)

Item #

Original Point ID New DCS Point ID Description 31 TCA-AVTEMP-4 TCA AVTPV RCS COLD LEG A AVG TEMP 32 TCB-AVTEMP-4 TCBAVTPV RCS COLD LEG B AVG TEMP 33 TCC-AVTEMP-4 TCC AVTP V RCS COLD LEG C AVG TEMP 34 RCSAVPRES-4 RCSAVP V RCS AVG WR PRESSURE 35 PRZ-AVLVL-4 PRZAVL V PRESSURIZER AVERAGE LEVEL 36 FT122-4 F122_A CHARGING FLOW 37 FT932-4 F932 A HHSI FLO A HL INSIDE CNTMT 38 FT933-4 F933 A HHSI FLO B HL INSIDE CNTMT 39 FT943-4 F943_A HHSI TO BORON INJ TANK 40 FT605-4 F605_A RHR SYSTEM FLOW 41 CTMTHILVLL-4 CHILVLL V CNTMT SUMP WATER LEVEL (AUCT MH HIGH) 42 CTMTHILVLH-4 CHILVLH-V CNTMT HR WATER LEVEL (AUCT MH HIGH) 43 R14-4" 3R14 A*

PLANT VENT GAS ACTIVITY RAD MON 44 RAD6304HR-4 R6304HR A PLANT VENT GAS GAMMA HI RANGE 45 RAD6304FLO-4 R6304FLO A PLANT VENT FLOW RATE 4 6 R18-4*

3R18 A*

LIQUID WASTE EFFLUENT RAD MON 47 R15-4 R15 A CONDENSER GAS EJECTOR RAD MON 48 RAD6417HR-4 R6417HR A AIR EJECTOR GAS GAMMA HI RANGE 49 CTMHRADW-4 CHRADW V CNTMT WR RADIATION (AUCT HIGH) 50 R20-4 R20 A RCS LETDOWN ACTIVITY RAD MON 51 RAD6426-4 R6426 A MAIN STM LINES GAMMA HI RANGE 52 R19-4 R19 A SG EFFLUENT PROCESS RAD MON 53 CTMTAVPRSW-4 CAVPRSW V CNTMT WR AVG PRESSURE 54 CTMTHITMP-4 CHITMPV CNTMT TEMP (AUCT HIGH) 55 CTMTH2CONC-4 CH2CONC V CNTMT H2 CONCENTRATION (AUCT CH HIGH) 56 RWST3AVLVL-4 RWSTAVLV RWST LEVEL (AUCT LOW) 57 WS-10M-TP-4 WS10M LU A WIND SPEED 10 METERS (TP) 58 WD-10M-TP-4 WD 1OM LU A WIND DIRECTION 10 METERS (TP) 59 D-TMP-A-SD-4 STABA SD A ESTIMATE OF ATMOS STABILITY

  • Common Point with Unit 3

ATTACHMENT 2 APPENDIX C PTN4 ERDS DATA POINT LIBRARY

Page 1 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NI Power Rng Point ID:

NIAVPRL V Plant Spec Point Desc:

Power Range Power Level Generic/Cond Desc:

Nuclear Instr, Power Range Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

120 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

4 How Processed:

4 Input Average, w/2.5 % of span Deviation Check Sensor Locations:

RX Vessel @ 45, 135, 225, & 315 degrees, 14'El Alarm/Trip Set Points:

Hi: 103% Hi-Hi Rx Trip: 108%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average is determined from NIs 41, 42, 43, & 44.

The Deviation check is the value at which this point Quality becomes Poor. The detector type is an excore dual ion chamber (upper-lower arrangement). Hi 103%

(Rod Stop) Hi Hi 108% (RX Trip). This instrument also inputs a 2/4 logic for a Low Power - Hi Flux Rx Trip signal at 25% power.

Page 2 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NI Inter Rng Point ID:

NIAVIRLV Plant Spec Point Desc:

Intermediate Range Power Level Generic/Cond Desc:

Nuclear Instr, Intermediate Range Analog/Digital:

A Engr Units/Dig States:

Amps Engr Units Conversion:

N/A Minimum Instr Range:

1.OE -11 Maximum Instr Range:

1.OE 3 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average Sensor Locations:

Rx Vessel @ 90 & 270 Deg. 14' El Alarm/Trip Set Points:

P6: 1.001 E -10 Amps NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply

<1.OE -10 Amps Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average is determined from N35_A and N36_A intermediate range channel signals. The detectors are compensated ion chambers located in the upper half of detector wells shared with the source range detectors.

The P6 setpoint is 1.001 E -10 Amps. This instrument also inputs a 1/2 logic Low Power Rx trip signal at 1.2 E 4 amps (equiv to 25% power).

Page 3 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NI Source Rng Point ID:

NIAVSRLV Plant Spec Point Desc:

Source Range Power Level Generic/Cond Desc:

Nuclear Instr, Source Range Analog/Digital:

A Engr Units/Dig States:

cps Engr Units Conversion:

N/A Minimum Instr Range:

1.OE +0 Maximum Instr Range:

1.OE +6 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average Sensor Locations:

Rx Vessel @ 90 & 270 Deg. 14' El.

Alarm/Trip Set Points:

Rx Trip at 1.0E5 cps NI Detector Power Supply

>1.0E4 cps (P6 Permissive)

Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average is determined from N3 1_A and N32_A source range channel signals. The detectors are in the lower half of detector wells shared with the intermediate range detectors.

Page 4 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

N6649AVP V Plant Spec Point Desc:

Gammametrics PR Avg Generic/Cond Desc:

Nuclear Instruments, Power Rng Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

N/A Minimum Instr Range:

1.OE 8 Maximum Instr Range:

200 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P2 Number of Sensors:

2 How Processed:

2 Input Average Sensor Locations:

RX Vessel @ 0 and 180 Deg. 14' El Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average is determined from NIs 6649A2 and 6649B2 Gammametrics Power Range Detectors. The detectors are located in the same wells as the Gammametrics Source Range Detectors.

Page 5 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

N6649AVSV Plant Spec Point Desc:

Gammametrics SR Avg Generic/Cond Desc:

Nuclear Instruments, Source Rng Analog/Digital:

A Engr Units/Dig States:

cps Engr Units Conversion:

N/A Minimum Instr Range:

1.0E 1 Maximum Instr Range:

1.0E +5 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average Sensor Locations:

RX Vessel @ 0 and 180 Deg. 14' El Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average is determined from NIs 6649A1 and 6649B 1 Gammametrics Source Range Detectors. The detectors are located in the same wells as the Gammametrics Power Range Detectors.

Page 6 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

Reac VesLev Point ID:

RXHDLLOV Plant Spec Point Desc:

Reactor Upper Head Level Generic/Cond Desc:

Reactor Vessel Water Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

TAF Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Low Select Sensor Locations:

RX Vessel - Upper Head Alarm/Trip Set Points:

Lo-Lo: 99.99%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Reactor head water level indication consists of the lower of 2 QSPDS Trains of the top 2 sensors (1 & 2) of an eight sensor probe. Each sensor consists of a heated and an unheated thermocouple pair. The probe extends from the top of the head to the top of the fuel alignment plate. Sensor 1 is at 179" (33% indicated) above the fuel and sensor 2 is 142" (0% indicated).

Page 7 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

RXPLLLO V Plant Spec Point Desc:

Reactor Plenum Water Level Generic/Cond Desc:

Reactor Vessel Plenum Water Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

TAF Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Low Select Sensor Locations:

Rx Vessel-Plenum Above Core Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Reactor plenum water level indication consists of the lower of 2 QSPDS Trains of the lower 6 sensors (3-8) of an eight sensor probe. Each sensor consists of a heated and an unheated thermocouple pair. Sensor locations above the fuel from top to bottom (i.e.,

sensors 3-8) are 128", 98", 69", 55", 40", and 24" respectively. Indicated levels are 81%, 58%, 40%,

28%, 16%, and 0% respectively.

Page 8 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

Temp Core Ex Point ID:

CET V Plant Spec Point Desc:

Core Exit Temperature Generic/Cond Desc:

Highest Temp At Core Exit Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

2300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Hi Select Sensor Locations:

Inside Reactor Vessel-Core Exit Area Alarm/Trip Set Points:

Lo: 540°F Hi: 650'F NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Signals originate from 2 QSPDS (Qualified Safety Parameter Display System) Channel Trains selecting the higher of 2 calculated representative core exit thermocouple (CET) temperatures. The representative CET temperature is the average of the highest eight valid CETs for that Train.

Page 9 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

Sub Margin Point ID:

SCMCETLO V Plant Spec Point Desc:

Subcooling Generic/Cond Desc:

Sat Temp - Highest CET Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

- 2100 Maximum Instr Range:

700 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Low Select Sensor Locations:

Core Exit Channels Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Signals originate from 2 QSPDS (Qualified Safety Parameter Display System) Channel Trains selecting the lower of 2 calculated subcooled margins. The QSPDS subcooled margin calculation for each Train uses a representative CET temperature input (based on statistical analyses) as measured against saturation temperature for existing RCS pressure.

Page 10 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

RCSAAVF V Plant Spec Point Desc:

RCS A Average Flow Generic/Cond Desc:

RCS Loop A Coolant Flow Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

1% = 895 GPM Minimum Instr Range:

0 Maximum Instr Range:

120 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/5 % of span Deviation Check Sensor Locations:

RCS Lower Loop Piping Alarm/Trip Set Points:

Lo: 104% LoLo Rx Trip: 90%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average flow is determined by FTs 414, 415, &

416 based on a differential pressure developed by a flow elbow located in the main coolant loop. The Deviation check (5370 gpm) is the value at which this point Quality becomes Poor. 100% flow: - 89,500 GPM. Lo RCS Flow Rx Trip at -90%. Minimum DNB flow: 104%.

Page 11 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

RCSB AVFV Plant Spec Point Desc:

RCS B Average Flow Generic/Cond Desc:

RCS Loop B Coolant Flow Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

1% = 895 GPM Minimum Instr Range:

0 Maximum Instr Range:

120 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/5 % of span Deviation Check Sensor Locations:

RCS Lower Loop Piping Alarm/Trip Set Points:

Lo: 104% LoLo Rx Trip: 90%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average flow is determined by FTs 424, 425, &

426 based on a differential pressure developed by a flow elbow located in the main coolant loop. The Deviation check (5370 gpm) is the value at which this point Quality becomes Poor. 100% flow: - 89,500 GPM. Lo RCS Flow Rx Trip at -90%. Minimum DNB flow: 104%.

Page 12 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

RCSCAVFV Plant Spec Point Desc:

RCS C Average Flow Generic/Cond Desc:

RCS Loop C Coolant Flow Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

1% = 895 GPM Minimum Instr Range:

0 Maximum Instr Range:

120 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/5 % of span Deviation Check Sensor Locations:

RCS Lower Loop Piping Alarm/Trip Set Points:

Lo: 104% LoLo Rx Trip: 90%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average flow is determined by FTs 434, 435, &

436 based on a differential pressure developed by a flow elbow located in the main coolant loop. The Deviation check (5370 gpm) is the value at which this point Quality becomes Poor. 100% flow: - 89,500 GPM. Lo RCS Flow Rx Trip at -90%. Minimum DNB flow: 104%.

Page 13 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

SG LEVEL 1/A Point ID:

SGAAVLV Plant Spec Point Desc:

Steam Generator Level A Generic/Cond Desc:

Steam Generator A Water Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

1% = 112.5 gallons Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

U-Tubes Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/10% of span Deviation Check Sensor Locations:

SG Vessel A 30' 6" EL Alarm/Trip Set Points:

Lo-Lo Rx Trip: 10% Lo: 35% Hi 68% Hi-Hi: 80%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

WET Unique System Desc:

The average level is determined by LTs 474, 475, &

476. The Deviation check is the value at which this point Quality becomes Poor.

0%

=16,250gal 100%

27,500 gal The lower tap is 8" above the top of the tube bundle.

Protection Train: 10 % Reactor Trip, 80 % Turbine Trip

Page 14 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

L477_A Plant Spec Point Desc:

Steam Generator A Wide Rng Level Generic/Cond Desc:

Steam Generator A WR Water Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

See Description Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

Tubesheet Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

Containment 30' 6" El Alarm/Trip Set Points:

Lo: 40% Hi: 93%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation No For DP Transmitters Level Reference Leg:

WET Unique System Desc:

0% = 750 gal 100% = 27,500 gal Percent to gal conversion is:

0-52 %: 187 gal /%

52-73 %: 274 gal/ %

73-100 %: 417 gal/%

Page 15 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

SG LEVEL 2/B Point ID:

SGB AVLV Plant Spec Point Desc:

Steam Generator Level B Generic/Cond Desc:

Steam Generator B Water Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

1% = 112.5 gallons Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

U-Tubes Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/10% of span Deviation Check Sensor Locations:

SG Vessel B 30' 6" EL Alarm/Trip Set Points:

Lo-Lo Rx Trip: 10% Lo: 35% Hi 68% Hi-Hi: 80%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

Wet Unique System Desc:

The average level is determined by LTs 484, 485, &

486. The Deviation check is the value at which this point Quality becomes Poor.

0%

= 16,250 gal 100% = 27,500 gal The lower tap is 8" above the top of the tube bundle.

Protection Train: 10 % Reactor Trip, 80 % Turbine Trip

Page 16 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

L487_A Plant Spec Point Desc:

Steam Generator B Wide Rng Level Generic/Cond Desc:

Steam Generator. B WR Water Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

See Description Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

Tubesheet Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

Containment 30' 6" El Alarm/Trip Set Points:

Lo: 40% Hi: 93%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation No For DP Transmitters Level Reference Leg:

WET Unique System Desc:

0% = 750 gal 100% = 27,500.gal Percent to gal conversion is:

0-52 %: 187gal/%

52-73 %: 274 gal / %

73-100 %: 417 gal/%

Page 17 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

SG LEVEL 3/C Point ID:

SGC AVLV Plant Spec Point Desc:

Steam Generator Level C Generic/Cond Desc:

Steam Generator C Water Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

1% = 112.5 gallons Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

U-Tubes Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/10% of span Deviation Check Sensor Locations:

SG Vessel C 30' 6" EL Alarm/Trip Set Points:

Lo-Lo Rx Trip: 10% Lo: 35% Hi 68% Hi-Hi: 80%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

Wet Unique System Desc:

The average level is determined by LTs 494, 495, &

496. The Deviation check is the value at which this point Quality becomes Poor.

0%

= 16,250 gal 100% = 27,500 gal The lower tap is 8" above the top of the tube bundle.

Protection Train: 10 % Reactor Trip, 80 % Turbine Trip

Page 18 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

L497_A Plant Spec Point Desc:

Steam Generator C Wide Rng Level Generic/Cond Desc:

Steam Generator C WR Water Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

See Description Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

Tubesheet Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

Containment 30' 6" El Alarm/Trip Set Points:

Lo: 40% Hi: 93%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation No For DP Transmitters Level Reference Leg:

WET Unique System Desc:

0% = 750 gal 100% = 27,500 gal Percent to gal conversion is:

0-52 %: 187 gal / %

  • 52-73 %: 274 gal/%

73-100 %: 417 gal/%

Page 19 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

SG PRESS 1/A Point ID:

SGA AVPV Plant Spec Point Desc:

Steam Generator Pressure A Generic/Cond Desc:

Steam Generator A Pressure Analog/Digital:

A Engr Units/Dig States:

psig Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

1400 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/25 psig Deviation Check Sensor Locations:

SG A Steam Line before MSIV Alarm/Trip Set Points:

Lo: 614 psig Hi: 1085 psig NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average pressure is determined by PTs 474, 475, &

476. The Deviation check is the value at which this point Quality becomes Poor.

ESF actuation signals:

SG pressure 100 psig < steam header pressure SG pressure of< 614 psig

Page 20 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

SG PRESS 2/B Point ID:

SGBAVPV Plant Spec Point Desc:

Steam Generator Pressure B Generic/Cond Desc:

Steam Generator B Pressure Analog/Digital:

A Engr Units/Dig States:

psig Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

1400 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/25 psig Deviation Check Sensor Locations:

SG B Steam Line before MSIV Alarm/Trip Set Points:

Lo: 614 psig Hi: 1085 psig NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average pressure is determined by PTs 484, 485, &

486. The Deviation check is the value at which this point Quality becomes Poor.

ESF actuation signals:

SG pressure 100 psig < steam header pressure SG pressure of < 614 psig

Page 21 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

SG PRESS 3/C Point ID:

SGC AVP V Plant Spec Point Desc:

Steam Generator Pressure C Generic/Cond Desc:

Steam Generator C Pressure Analog/Digital:

A Engr Units/Dig States:

psig Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

1400 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/25 psig Deviation Check Sensor Locations:

SG C Steam Line before MSIV Alarm/Trip Set Points:

Lo: 614 psig Hi: 1085 psig NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

N/A Temperature Compensation As-Is For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average pressure is determined by PTs 494, 495, &

496. The Deviation check is the value at which this point Quality becomes Poor.

ESF actuation signals:

SG pressure 100 psig < steam header pressure SG pressure of < 614 psig

Page 22 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

MN FD FL 1/A Point ID:

SGAAVFWFV Plant Spec Point Desc:

Feedwater Flow A SG Generic/Cond Desc:

Steam Generator A Mn Feedwater Fl Analog/Digital:

A Engr Units/Dig States:

lb/Hr Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

4.OE +6 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

Upstream FW Regulating Valve Alarm/Trip Set Points:

See Description NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average feedwater flow is determined by isolated signals from LTs 476 & 477. The Deviation check is the value at which this point Quality becomes Poor.

This Protection Train instrumentation has 2 separate channels of input to a reactor trip signal when:

Feedwater flow < Steam Flow @ 640,000 lb/Hr coincident SG level of -10%

Feedwater < Steam Flow alarm @ 500,000 lb/Hr

Page 23 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

MN FD FL 2/B Point ID:

SGBAVFWFV Plant Spec Point Desc:

Feedwater Flow B SG Generic/Cond Desc:

Steam Generator B Mn Feedwater Fl Analog/Digital:

A Engr Units/Dig States:

lb/Hr Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

4.OE +6 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

Upstream FW Regulating Valve Alarm/Trip Set Points:

See Description NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average feedwater flow is determined by isolated signals from LTs 486 & 487. The Deviation check is the value at which this point Quality becomes Poor.

This Protection Train instrumentation has 2 separate channels of input to a reactor trip signal when:

Feedwater flow < Steam Flow @ 640,000 lb/Hr coincident SG level of -10%

Feedwater < Steam Flow alarm @ 500,000 lb/Hr

Page 24 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

MN FD FL 3/C Point ID:

SGCAVFWF V Plant Spec Point Desc:

Feedwater Flow C SG Generic/Cond Desc:

Steam Generator C Mn Feedwater Fl Analog/Digital:

A Engr Units/Dig States:

lb/Hr Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

4.OE +6 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

Upstream FW Regulating Valve Alarm/Trip Set Points:

See Description NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average feedwater flow is determined by isolated signals from LTs 496 & 497. The Deviation check is the value at which this point Quality becomes Poor.

This Protection Train instrumentation has 2 separate channels of input to a reactor trip signal when:

Feedwater flow < Steam Flow @ 640,000 lb/Hr coincident SG level of -10%

Feedwater < Steam Flow alarm @ 500,000 lb/Hr

Page 25 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

AX FD FL 1/A Point ID:

SGAAFWFV Plant Spec Point Desc:

Aux Feedwater Flow A SG Generic/Cond Desc:

Steam Generator A Aux FW Flow Analog/Digital:

A Engr Units/Dig States:

gpm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Sum Sensor Locations:

Aux FW lines Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Total AFW flow is the sum of Train One and Train Two to each SG. The aux feed is supplied by 3 steam driven pumps which discharge to 2 redundant trains.

Each train supplies flow to both Units and may feed any of the SGs. Administratively, pump A is aligned to Train One and pumps B and C to Train Two. The 2 condensate storage tanks are the normal water supplies to the AFW pumps.

Page 26 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

AX FD FL 2/B Point ID:

SGBAFWFV Plant Spec Point Desc:

Aux Feedwater Flow B SG Generic/Cond Desc:

Steam Generator B Aux FW Flow Analog/Digital:

A Engr Units/Dig States:

gpm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Sum Sensor Locations:

Aux FW lines Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Total AFW flow is the sum of Train One and Train Two to each SG. The aux feed is supplied by 3 steam driven pumps which discharge to 2 redundant trains.

Each train supplies flow to both Units and may feed any of the SGs. Administratively, pump A is aligned to Train One and pumps B and C to Train Two. The 2 condensate storage tanks are the normal water supplies to the AFW pumps.

Page 27 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

AX FD FL 3/C Point ID:

SGCAFWFV Plant Spec Point Desc:

Aux Feedwater Flow C SG Generic/Cond Desc:

Steam Generator C Aux FW Flow Analog/Digital:

A Engr Units/Dig States:

gpm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Sum Sensor Locations:

Aux FW lines Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Total AFW flow is the sum of Train One and Train Two to each SG. The aux feed is supplied by 3 steam driven pumps which discharge to 2 redundant trains.

Each train supplies flow to both Units and may feed any of the SGs. Administratively, pump A is aligned to Train One and pumps B and C to Train Two. The 2 condensate storage tanks are the normal water supplies to the AFW pumps.

Page 28 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

HL TEMP 1/A Point ID:

THAAVTPV Plant, Spec Point Desc:

RCS Hot Leg A Avg Temp Generic/Cond Desc:

Steam Generator A Inlet Temp Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

750 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

RCS Hot Leg A Piping 14' El Alarm/Trip Set Points:

Lo: 540'F Hi: 610°F NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average temperature is determined by TTs 413A &

413B. The Deviation check is the value at which this point Quality becomes Poor. The sensors are platinum RTDs which are located in wells in the main coolant loops. The loop T-Hot signals are also inputs to the Qualified Safety Parameter Display System.

Page 29 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

HL TEMP 2/B Point ID:

THBAVTP V Plant Spec Point Desc:

RCS Hot Leg B Avg Temp Generic/Cond Desc:

Steam Generator B Inlet Temp Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

750 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

RCS Hot Leg B Piping 14' El Alarm/Trip Set Points:

Lo: 540'F Hi: 610'F NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average temperature is determined by TTs 423A &

423B. The Deviation check is the value at which this point Quality becomes Poor. The sensors are platinum RTDs which are located in wells in the main coolant loops. The loop T-Hot signals are also inputs to the Qualified Safety Parameter Display System.

Page 30 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

HL TEMP 3/C Point ID:

THCAVTP V Plant Spec Point Desc:

RCS Hot Leg C Avg Temp Generic/Cond Desc:

Steam Generator C Inlet Temp Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

750 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

RCS Hot Leg C Piping 14' El Alarm/Trip Set Points:

Lo: 540'F Hi: 610'F NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average temperature is determined by TTs 433A &

433B. The Deviation check is the value at which this point Quality becomes Poor. The sensors are platinum RTDs which are located in wells in the main coolant loops. The loop T-Hot signals are also inputs to the Qualified Safety Parameter Display System.

Page 31 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CL TEMP 1/A Point ID:

TCA AVTPV Plant Spec Point Desc:

RCS Cold Leg A Avg Temp Generic/Cond Desc:

Steam Generator A Outlet Temp Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

750 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

RCS Cold Leg A Piping 14' El Alarm/Trip Set Points:

Lo: 540'F H: 555 0F NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average temperature is determined by TTs 410A &

4 10B. The Deviation check is the value at which this point Quality becomes Poor. The sensors are platinum RTDs which are located in wells in the main coolant loops. The loop T-Cold signals are also inputs to the Qualified Safety Parameter Display System.

Page 32 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CL TEMP 2/B Point ID:

TCBAVTPV Plant Spec Point Desc:

RCS Cold Leg B Avg Temp Generic/Cond Desc:

Steam Generator B Outlet Temp Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

750 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

RCS Cold Leg B Piping 14' El Alarm/Trip Set Points:

Lo: 540'F Hi: 555°F NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average temperature is determined by TTs 420A &

420B. The Deviation check is the value at which this point Quality becomes Poor. The sensors are platinum RTDs which are located in wells in the main coolant loops. The loop T-Cold signals are also inputs to the Qualified Safety Parameter Display System.

Page 33 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CL TEMP 3/C Point ID:

TCC AVTPV Plant Spec Point Desc:

RCS Cold Leg C Avg Temp Generic/Cond Desc:

Steam Generator C Outlet Temp Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

750 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

RCS Cold Leg C Piping 14' El Alarm/Trip Set Points:

Lo: 540'F H: 555°F NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average temperature is determined by TTs 430A &

430B. The Deviation check is the value at which this point Quality becomes Poor. The sensors are platinum RTDs which are located in wells in the main coolant loops. The loop T-Cold signals are also inputs to the Qualified Safety Parameter Display System.

Page 34 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

RCS PRESSURE Point ID:

RCSAVPV Plant Spec Point Desc:

RCS Pressure WR Generic/Cond Desc:

Reactor Coolant System Pressure Analog/Digital:

A Engr Units/Dig States:

psig Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

3000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

RCS Loop A & B Hot Legs 14' El Alarm/Trip Set Points:

Lo: 1910 psig Hi: 2310 psig NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average RCS pressure is determined by PTs 404 &

406. The Deviation check is the value at which this point Quality becomes Poor.

Page 35 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

PRZR LEVEL Point ID:

PRZAVL V Plant Spec Point Desc:

Pressurizer Average Level Generic/Cond Desc:

Primary System Pressurizer Level Analog/Digital:

A Engr Units/Dig States:

Engr Units Conversion:

1% = 84.5 gallons Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

Compix Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Average w/5% of span Deviation Check Sensor Locations:

PRZ Vessel 30' El Alarm/Trip Set Points:

Lo: 14% Hi: 92%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation No For DP Transmitters Level Reference Leg:

Wet Unique System Desc:

The pressurizer average level is calculated using 5 minute rolling averages of LTs 459, 460, & 461. The Deviation check is the value at which this point Quality becomes Poor. The instrument range of 0-100% is equivalent to 600-9050 gallons. Protection Channel inputs include: PZR Hi-Level Rx trip (2/3 at 9 1%),

Lo-Lo level alarm at 6%, PZR heaters Off and letdown isolate at 14.4%, Hi level alarm and heaters on at +5%

program, and Lo level alarm at -5% program.

Page 36 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

RCS CHG/MU Point ID:

F122_A Plant Spec Point Desc:

Charging Flow Generic/Cond Desc:

Primary System Charging/MU Flow Analog/Digital:

A Engr Units/Dig States:

gpm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

150 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

Charging Pumps Discharge Header Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Charging flow is provided by 3 electrically driven positive displacement pumps. The discharge is to a common header (where the flow is measured) and provides cooled RCP seal water flow and re-heated flow that can be directed to loops A cold leg, C hot leg, or to the pressurizer auxiliary spray line. Charging flow rate is normally controlled by pressurizer level.

Page 37 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

F932_A Plant Spec Point Desc:

HHSI Flo A HL Inside Containment Generic/Cond Desc:

High Press SI Flow To HL A Analog/Digital:

A Engr Units/Dig States:

gpm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

On SI line to Hot Leg A 14' El Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

FT-932 measures HHSI flow to the loop A hot leg.

HHSI is provided by 2 electrically driven pumps. The water supply is the Unit 3 RWST. The discharge of each pump is directed to a common discharge header to the A and/or B hot legs. Note: The Unit 3 & 4 RWSTs may be cross-connected and Unit 3 & 4 HHSI pumps discharge headers may be cross-connected.

Page 38 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

F933_A Plant Spec Point Desc:

HHSI Flo B HL Inside Containment Generic/Cond Desc:

High Press SI Flow To HL B Analog/Digital:

A Engr Units/Dig States:

gpm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

600 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

On SI line to Hot Leg B 14' El Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

FT-933 measures HHSI flow to loop A and/or B hot legs. HHSI is provided by 2 electrically driven pumps.

The water supply is the Unit 3 RWST. The discharge of each pump is directed to a common discharge header to the A and/or B hot legs. Note: The Unit 3 & 4 RWSTs may be cross-connected and Unit 3 & 4 HHSI pumps discharge headers may be cross-connected.

Page 39 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

HPSI FLOW Point ID:

F943 A Plant Spec Point Desc:

HHSI Flo To BIT To Cold Legs Generic/Cond Desc:

High Press SI Flow To Cold Legs Analog/Digital:

A Engr Units/Dig States:

gpm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

1000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

SI line upstream of Discharge Header MOVs Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

FT-943 measures total HHSI flow to loops A, B, and C cold legs. HHSI is provided by 2 electrically driven pumps. The water supply is the Unit 3 RWST. The discharge of each pump is directed to a common discharge header to the 3 cold legs. Note: The Unit 3

& 4 RWSTs may be cross-connected and Unit 3 & 4 HHSI pumps discharge headers may be cross-connected.

Page 40 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

LP SI FLOW Point ID:

F605_A Plant Spec Point Desc:

RHR System Flow Generic/Cond Desc:

Lo Pressure SI Flow Analog/Digital:

A Engr Units/Dig States:

gpm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

8500 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1il How Processed:

N/A Sensor Locations:

RHR/SI Header to Cold Legs (in RHR HX Room)

Alarm/Trip Set Points:

Hi: 7000 gpm NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation No For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

FT-605 measures the Residual Heat Removal (RHR) flow. RHR is provided by 2 RHR pumps. Each pump discharges to its own associated heat exchanger. Flow from the heat exchangers are combined into a single header for penetration into containment. Flow in this header is measured by FT-605, flow is then directed to loops A, B, and C cold legs. This flow signal also actuates a low flow alarm annunciator at 3000 gpm.

Page 41 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CTMNT SMP NR Point ID:

CHILVLLV Plant Spec Point Desc:

CNTMT LR Sump Water Level Generic/Cond Desc:

Containment Sump Lo-Range Level Analog/Digital:

A Engr Units/Dig States:

Inches Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

369 Zero Point

Reference:

-18' 8" El Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Hi Select w/ 5% of span Deviation Check Sensor Locations:

Containment Sump Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Containment level is the higher of the 2 containment level channels. The Deviation check is the value at which this point Quality becomes Poor. Each channel consists of 5 segment, float and reed switch level column. The level column starts at the -18' 8" elevation (i.e., below sea level) and covers 30'9" of level. The conversion from inches to gallons is non-linear. Note:

The elevation between 12' and 14'3" is not covered by the containment sump or level transmitters.

Page 42 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CTMNT SMP WR Point ID:

CHILVLHV Plant Spec Point Desc:

CNTMT HR Water Level Generic/Cond Desc:

Containment Sump Hi-Range Level Analog/Digital:

A Engr Units/Dig States:

Inches Engr Units Conversion:

N/A Minimum Instr Range:

397 Maximum Instr Range:

487 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Hi Select w/ 5% of span Deviation check Sensor Locations:

Containment Floor 14' El & Above Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Containment level is the higher of the 2 containment level channels. The Deviation check is the value at which this point Quality becomes Poor. Each channel consists of a float and reed switch level column. The level column starts at the 14'3" elevation and covers 7'6" of level. The conversion from inches to gallons is non-linear. Note: The elevation between 12' and 14'3" is not covered by the containment sump or containment level transmitters.

Page 43 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

3R14 A Plant Spec Point Desc:

Plant Vent Gas Activity Generic/Cond Desc:

Radioactivity Of A Released Gas Analog/Digital:

A Engr Units/Dig States:

cpm Engr Units Conversion:

N/A Minimum Instr Range:

10 Maximum Instr Range:

1.0 E6 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

Top Of Plant Vent Stack Alarm/Trip Set Points:

Determined By Radiochemist NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Radiation monitor R-14 is installed inside the plant vent. It consists of 4 thin-walled Gieger-Mueller tube detectors arranged across the plant vent stack diameter.

The 4 detectors operate in parallel, are Beta-Gamma sensitive in the range of 5E7 to 1E-A Ci/cc, and have a check source. R-14 alarm will automatically close the Gas Decay Tank discharge valve upon actuation. Note:

cpm to uCi/cc conversion factor is 2E8 ml/cc at sample flow rate.

Page 44 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

EFF GAS RAD Point ID:

R6304HRA Plant Spec Point Desc:

Plant Vent Gas Gamma Hi Range Generic/Cond Desc:

Radioactivity Of Released Gases Analog/Digital:

A Engr Units/Dig States:

uCi/cc Engr Units Conversion:

N/A Minimum Instr Range:

1.0E-1 Maximum Instr Range:

1.0E5 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

1 How Processed:

Data Link Sensor Locations:

Auxiliary Building Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

An Eberline SPING Unit provides Plant Vent High Range Noble Gas Activity. The detector type is a Geiger-Mueller tube, uncompensated with a check source. The plant vent stack is the normal discharge path for: Unit 3 & 4 containment purge, auxiliary building exhaust and Unit 4 SFP. Note: Unit 3 SFP exhaust is through a dedicated stack.

Page 45 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

R6304FLOA Plant Spec Point Desc:

Plant Vent Flow Rate Generic/Cond Desc:

Plant Vent Stack Flow Rate Analog/Digital:

A Engr Units/Dig States:

cfm Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

1.5E+5 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

1 How Processed:

Data Link Sensor Locations:

Plant Vent Stack Near Top Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Plant vent flow is provided by transmitter FT-6584 which measures the differential pressure across a flow orifice installed in the plant vent stack. The signal is processed by an optional analog to digital channel

(#10) on the Plant Vent SPING unit. Note: Loss of plant vent flow channel will not affect the calibration of the plant vent high range gas monitor which is based on a fixed sample flow rate.

Page 46 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

EFF LIQ RAD Point ID:

3R18 A Plant Spec Point Desc:

Liquid Release Gross Activity Generic/Cond Desc:

Radioactivity Of Released Liquid Analog/Digital:

A Engr Units/Dig States:

cpm Engr Units Conversion:

N/A Minimum Instr Range:

10 Maximum Instr Range:

1.0E+6 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

Liquid Release Line In Aux Bldg Alarm/Trip Set Points:

Determined By Radiochemist NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Radiation monitor R-18 monitors liquid waste release activity in the waste discharge header upstream of the liquid release isolation valve RCV-018. The detector is a sodium iodide scintillation tube, lead shielded against background. The alarm setpoint is plant condition dependent and set by the Radiochemist. The liquid waste control valve (RCV-18) auto isolates on a high activity alarm. Note: the cpm to uci/cc conversion factor is 2.96E7 ml-cpm at 100 gpm.

Page 47 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

R15-A Plant Spec Point Desc:

Condenser Air Ejector (PRMS)

Generic/Cond Desc:

Condenser Air Ejector Rad Analog/Digital:

A Engr Units/Dig States:

cpm Engr Units Conversion:

N/A Minimum Instr Range:

10 Maximum Instr Range:

1.0E÷6 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

Turbine Deck Alarm/Trip Set Points:

Determined By Radiochemist NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

R-15, the Condenser Air Ejector Monitor uses a thin wall Geiger-Mueller tube detector. The detector is located in the air ejector exhaust manifold and uses lead shielding against background. The alarm setpoint is plant condition dependent and is determined by the Radiochemist.

Page 48 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CONDA/E RAD Point ID:

R6417HR A Plant Spec Point Desc:

Air Ejector Gas Gamma Hi-Rng Generic/Cond Desc:

Condenser Air Ejector Rad Analog/Digital:

A Engr Units/Dig States:

uCi/cc Engr Units Conversion:

N/A Minimum Instr Range:

1.0EI Maximum Instr Range:

1.0E+5 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

1 How Processed:

Data Link Sensor Locations:

Turbine Deck Alarm/Trip Set Points:

Determined By Radiochemist NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

M/A Unique System Desc:

An Eberline SPING Unit provides the Air Ejector Plant Vent Hi-Range Noble Gas Activity. The detector type is a Gieger-Mueller tube, uncompensated with a check source.

Page 49 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CNTMT RAD Point ID:

CHRADWV Plant Spec Point Desc:

Containment Radiation (WR)

Generic/Cond Desc:

Radiation Level In Containment Analog/Digital:

A Engr Units/Dig States:

RiHr Engr Units Conversion:

N/A Minimum Instr Range:

1.0 Maximum Instr Range:

1.0E+8 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Hi Select w/ 5 % Deviation limit Sensor Locations:

Rx Bldg @ 25' & 64' El Alarm/Trip Set Points:

Hi: 1.3E4 R/Hr Hi-Hi: 1.3E5 R/Hr NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply.

N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Containment radiation is the higher of 2 channel inputs (RAD6311A and RAD6311B). The Deviation check is the value at which this point Quality becomes Poor.

Both use ion chamber detectors. RAD631 1A is located inside containment on the 25' level near the personnel hatch and RAD631 lB is near the 64' level on the SG shield wall near the pressurizer ARMS channel R-2.

These channels have 2 Hi Alarm setpoints, the first one activating an annunciator.

Page 50 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

RCS LTDN RAD Point ID:

R20OA Plant Spec Point Desc:

RCS Letdown Line Activity Generic/Cond Desc:

Rad Level Of The RCS Letdown Analog/Digital:

A Engr Units/Dig States:

mR/Hr Engr Units Conversion:

N/A Minimum Instr Range:

1.0 Maximum Instr Range:

1.0E+5 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

RCS letdown piping upstream of HX Alarm/Trip Set Points:

Hi 5.0E+4 mR/Hr NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

Low Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

R-20 provides reactor coolant letdown line activity.

The monitor is located on the letdown line, outside of containment and upstream of the non-regenerative heat exchanger. The monitor is external to the piping system and far enough from the coolant loop that a 40 second transient time is provided for N 16 gamma decay. The detector is a Geiger-Mueller tube.

Page 51 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

N/L Point ID:

R6426_A Plant Spec Point Desc:

Main Stm Lines Gamma Hi Rng Generic/Cond Desc:

Main Steam Lines Radioactivity Analog/Digital:

A Engr Units/Dig States:

uCi/cc Engr Units Conversion:

N/A Minimum Instr Range:

1.0E1 Maximum Instr Range:

1.0E+5 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

1 How Processed:

Data Link Sensor Locations:

Main Steam Sample lines Alarm/Trip Set Points:

Determined By Plant Radiochemist NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

RAD6426-Main Steam Line High Range Gamma is measured by the Eberline DAM-1. Detector type is a Gieger-Mueller Tube with no compensation. Note:

sample lines from all 6 SGs run simultaneously through the detector. To identify a ruptured SG, manual isolation valves must be operated.

Page 52 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

NL Point ID:

R19-A Plant Spec Point Desc:

Stm Gen Liquid Sample Activity Generic/Cond Desc:

SG Blowdown Radioactivity Analog/Digital:

A Engr Units/Dig States:

cpm Engr Units Conversion:

N/A Minimum Instr Range:

10 Maximum Instr Range:

1.0E+6 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

Auxiliary Bldg N-S Hallway Alarm/Trip Set Points:

Determined By Radiochemist NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

10 Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Detector type - Scintillation. Located in the-combined SG sample line. R-19 provides for auto closure of all 3 (Unit 3) SG sample lines, all 3 blowdown flow control valves, and both (2) blowdown tank drain valves. High Alarm setpoint is determined by Radiochemist based on plant conditions.

Page 53 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CTMNT PRESS Point ID:

CAVPRSW V Plant Spec Point Desc:

Containment Pressure (WR)

Generic/Cond Desc:

Containment Pressure Analog/Digital:

A Engr Units/Dig States:

psig Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

180 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

South Penetration Room Alarm/Trip Set Points:

Hi: 20 psig Hi-Hi: 55 psig NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The average containment pressure is determined by PTs 6306A & 6306B. The Deviation check is the value at which this point Quality becomes Poor. Containment pressure transmitters provide containment Hi and Hi-Hi actuation of the ESFAS circuitry at 4 psig and 20 psig respectively. Hi containment pressure actuates Safety Injection, while the Hi-Hi pressure coincident with the Hi pressure will actuate containment sprays and Phase B Containment Isolation.

Page 54 of 59

. TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

CTMNT TEMP Point ID:

CHITMP V Plant Spec Point Desc:

Containment Temperature Generic/Cond Desc:

Containment Temperature Analog/Digital:

A Engr Units/Dig States:

OF Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

300 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

3 How Processed:

3 Input Hi Select w/100 F Deviation Check Sensor Locations:

Containment El 58' @ 1200 Intervals Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

The containment temperature is the highest of 3 channels (TE6700, TE6701, and TE6702). The Deviation check is the value at which this point Quality becomes Poor. Each channel uses a platinum RTD.

TE6700 is located near the 3B Normal Containment Cooler, TE6701 is located near the 3C Normal Containment Cooler, TE6702 is located near the 3C Emergency Containment Filters. CHITMPV provides an input to DEGCNTMT V alarm @ 140 OF.

Page 55 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

H2 CONC Point ID:

CH2CONCV Plant Spec Point Desc:

CTMT Hydrogen Concentration Generic/Cond Desc:

Containment Atmosphere H2 Conc Analog/Digital:

A Engr Units/Dig States:

% H2 Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

10 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Hi Select w/5 % of span Deviation check Sensor Locations:

Aux Bldg Basement Alarm/Trip Set Points:

4%

NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

This value represents the higher of 2 channels, A6307A

& A6307B. The Deviation check is the value at which this point Quality becomes Poor. The % H2 signal is developed by comparing the thermal conductivity of a reference sample with the conductivity of a sample after removing nitrogen. The system provides a high H2 annunciator alarm at 7.5%, Low and Hi Cell Failure, Calibration Gas Low Pressure, Reagent Gas Low Pressure, and Low Analyzer Flow Alarm.

Page 56 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

RWST LEVEL Point ID:

RWSTAVLV Plant Spec Point Desc:

RWST (Unit 4) Average Level Generic/Cond Desc:

Borated Water Storage Tank Level Analog/Digital:

A Engr Units/Dig States:

gal Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

335,000 gals Zero Point

Reference:

TNKBOT Reference Point Notes:

N/A PROC or SENS:

P Number of Sensors:

2 How Processed:

2 Input Average w/ 5 % of span Deviation Check Sensor Locations:

Ground Level by RWST Alarm/Trip Set Points:

See Description NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

As-Is Temperature Compensation N/A For DP Transmitters Level Reference Leg:

DRY Unique System Desc:

The average level is determined by LTs 6583A &

6583B. The Deviation check is the value at which this point Quality becomes Poor. Each RWST level loop consists of a Rosemount DP transmitter and Foxboro Modules to provide alarm and indication functions.

Alarms provided are: Lo-Lo Level at 60,000 gallons, Low Level at 155,000 gallons, Tech Spec Min Level at 322,000 gallons and Hi Level at 333,000 gallons.

Note: the RWST is the Borated Water Storage Tank.

Page 57 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

WIND SPEED Point ID:

WS1OM LU A Plant Spec Point Desc:

10 Meter Wind Speed (T.P.)

Generic/Cond Desc:

Wind Speed At Reactor Site Analog/Digital:

A Engr Units/Dig States:

mph Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

100 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

10 Meter Tower 1 Mile SW of Plant Alarm/Trip Set Points:

Hi: 75 mph Hi-Hi: 90 mph NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

0 Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Wind Speed meteorological data is gathered by instruments mounted on a 10 meter tower. The data (a 15 minute running average). is transmitted by radio to the plant and is received by the Campbell Scientific equipment located in the Plant Computer Room.

Page 58 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

WIND DIR Point ID:

WD1OM LU A Plant Spec Point Desc:

10 Meter Wind Direction (T.P.)

Generic/Cond Desc:

Wind Direction At Reactor Site Analog/Digital:

A Engr Units/Dig States:

0 (Degrees)

Engr Units Conversion:

N/A Minimum Instr Range:

0 Maximum Instr Range:

540 Zero Point

Reference:

N/A Reference Point Notes:

0 And 360 Are North. Switch Pt 180 PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

10 Meter Tower 1 Mile Sw Of Plant Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

0 Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Wind direction is provided by instruments mounted on a 10 meter tower. The data (a 15 minute running average) is transmitted by radio to the plant and is received by the Campbell Scientific equipment located in the Computer Room. The 10 Meter Tower is located 1 mile SW of the site. Note: Wind is coming from direction reported by the instrument, with 0 and 360 being North.

Page 59 of 59 TP4 DATA POINT LIBRARY REFERENCE FILE Date:

02/25/08 Reactor Unit:

TP4 Data Feeder:

N/A NRC ERDS Parameter:

STABB CLASS Point ID:

STABASDA Plant Spec Point Desc:

Estimate Of Atmos Stability Generic/Cond Desc:

Air Stability At A Reactor Site Analog/Digital:

A Engr Units/Dig States:

df/mm Engr Units Conversion:

N/A Minimum Instr Range:

-5 Maximum Instr Range:

15 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROC or SENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Locations:

60 Meter Tower 7 Miles SSW Of Plant Alarm/Trip Set Points:

N/A NI Detector Power Supply N/A Cut-off Power Level:

NI Detector Power Supply N/A Turn-On Power Level:

Instrument Failure Mode:

-5 Temperature Compensation N/A For DP Transmitters Level Reference Leg:

N/A Unique System Desc:

Atmospheric stability is developed by taking the difference between the temperature at the 10 meter and 60 meters. The difference is multiplied by 2 to obtain the change per 100 meters altitude. A 15 minute running average data transmitted by radio telemetry to a Campbell Scientific receiver in the Plant Computer Room.