Category:Annual Operating Report
MONTHYEARL-2023-122, Corrections to the 2022 Annual Radiological Environmental Operating Report2023-09-20020 September 2023 Corrections to the 2022 Annual Radiological Environmental Operating Report L-2023-108, Report of 10 CFR 50.59 Plant Changes2023-09-11011 September 2023 Report of 10 CFR 50.59 Plant Changes L-2022-062, Annual Radiological Environmental Operating Report for Calendar Year 20212022-04-13013 April 2022 Annual Radiological Environmental Operating Report for Calendar Year 2021 L-2021-082, Submittal of 2020 Annual Environmental Operating Report2021-04-15015 April 2021 Submittal of 2020 Annual Environmental Operating Report L-2021-066, CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2021-04-14014 April 2021 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2020-044, Report of 10 CFR 50.59 Plant Changes2020-04-20020 April 2020 Report of 10 CFR 50.59 Plant Changes L-2020-068, 2019 Annual Environmental Operating Report2020-04-15015 April 2020 2019 Annual Environmental Operating Report L-2020-041, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2020-04-14014 April 2020 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2020-027, 2019 Annual Operating Report2020-01-12012 January 2020 2019 Annual Operating Report L-2019-044, Report of 10 CFR 50.59 Plant Changes2019-03-27027 March 2019 Report of 10 CFR 50.59 Plant Changes L-2019-057, Cf~ 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2019-03-19019 March 2019 Cf~ 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2019-039, 2018 Annual Operating Report2019-02-27027 February 2019 2018 Annual Operating Report L-2018-087, Transmittal of 2017 Annual Environmental Operating Report2018-04-10010 April 2018 Transmittal of 2017 Annual Environmental Operating Report L-2018-063, CFR 50.46 Annual Reporting and 30-day Notification of Changes or Errors in Emergency Core Cooling System Models or Applications2018-03-26026 March 2018 CFR 50.46 Annual Reporting and 30-day Notification of Changes or Errors in Emergency Core Cooling System Models or Applications L-2018-051, 2017 Annual Operating Report2018-02-22022 February 2018 2017 Annual Operating Report L-2017-071, Submittal of Report of 10 CFR 50.59 Plant Changes, Tests and Experiments2017-05-0404 May 2017 Submittal of Report of 10 CFR 50.59 Plant Changes, Tests and Experiments L-2017-056, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CPR 50.46 Annual Report2017-03-27027 March 2017 Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CPR 50.46 Annual Report L-2017-016, Transmittal of 2016 Annual Operating Report2017-02-0707 February 2017 Transmittal of 2016 Annual Operating Report L-2016-049, Annual Operating Report for St. Lucie 1 and 2, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors2016-03-0202 March 2016 Annual Operating Report for St. Lucie 1 and 2, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors L-2014-095, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CFR 50.46 Annual Report2014-03-31031 March 2014 Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CFR 50.46 Annual Report L-2004-050, Cy 2003 Corrections to Annual Radioactive Effluent Release Report (L-2004-050 Dated February 27, 2004) Section 10. Process Control Program (PCP) Revisions, Page 6 and AP 0520025 Revision 13A with mark-up2014-02-27027 February 2014 Cy 2003 Corrections to Annual Radioactive Effluent Release Report (L-2004-050 Dated February 27, 2004) Section 10. Process Control Program (PCP) Revisions, Page 6 and AP 0520025 Revision 13A with mark-up L-2014-048, Annual Operating Report2014-02-12012 February 2014 Annual Operating Report L-2013-012, Annual Operating Report2013-01-0909 January 2013 Annual Operating Report L-2012-361, Report of 10 CFR 50.59 Plant Changes2012-10-0101 October 2012 Report of 10 CFR 50.59 Plant Changes L-2012-170, Annual Environmental Operating Report2012-04-24024 April 2012 Annual Environmental Operating Report L-2012-080, Annual Radioactive Effluent Release Report January 1, 2011 Through December 31, 2011, C-200, Offsite Dose Calculation Manual Revision 35.2012-03-0101 March 2012 Annual Radioactive Effluent Release Report January 1, 2011 Through December 31, 2011, C-200, Offsite Dose Calculation Manual Revision 35. ML12068A2072012-03-0101 March 2012 Annual Radioactive Effluent Release Report January 1, 2011 Through December 31, 2011 L-2012-073, 2011 Annual Operating Report2012-02-21021 February 2012 2011 Annual Operating Report L-2011-147, 2010 Annual Environmental Operating Report2011-04-20020 April 2011 2010 Annual Environmental Operating Report L-2011-116, Annual Radiological Environmental Operating Report for Calendar Year 20102011-04-19019 April 2011 Annual Radiological Environmental Operating Report for Calendar Year 2010 ML1109701462011-03-30030 March 2011 Units I and 2, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CFR 50.46 Annual Report L-2010-058, Annual Radiological Environmental Operating Report for Calendar Year 20092010-03-22022 March 2010 Annual Radiological Environmental Operating Report for Calendar Year 2009 ML1006106442010-02-25025 February 2010 St. Lucie, Units 1 and 2, Combined Annual Radioactive Effluent Release Report for the Period January 1, 2009 Through December 31, 2009 L-2010-033, St. Lucie, Units 1 and 2, Combined Annual Radioactive Effluent Release Report for the Period January 1, 2009 Through December 31, 20092010-02-25025 February 2010 St. Lucie, Units 1 and 2, Combined Annual Radioactive Effluent Release Report for the Period January 1, 2009 Through December 31, 2009 L-2009-090, Annual Radiological Environmental Operating Report for Calendar Year 20082009-04-13013 April 2009 Annual Radiological Environmental Operating Report for Calendar Year 2008 L-2009-061, Submittal of Annual Report Acceptance Criteria for Emergency Core Cooling System Analyses for Light Water Nuclear Power Reactors2009-03-11011 March 2009 Submittal of Annual Report Acceptance Criteria for Emergency Core Cooling System Analyses for Light Water Nuclear Power Reactors L-2008-169, Amended Annual Radiological Environmental Operating Report for Calendar Year 20072008-07-28028 July 2008 Amended Annual Radiological Environmental Operating Report for Calendar Year 2007 L-2008-046, Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CFR 50.46 Annual Report2008-03-18018 March 2008 Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors 10 CFR 50.46 Annual Report L-2007-074, 2006 Annual Environmental Operating Report2007-04-25025 April 2007 2006 Annual Environmental Operating Report L-2007-021, Annual Operating Report2007-02-21021 February 2007 Annual Operating Report L-2006-263, Report of 10 CFR 50.59 Plant Changes During Period of February 15, 2005 Through June 12, 20062006-12-0505 December 2006 Report of 10 CFR 50.59 Plant Changes During Period of February 15, 2005 Through June 12, 2006 ML0612501642006-04-27027 April 2006 St. Lucie, Units 1 & 2 - 2005 Annual Environmental Operating Report L-2006-098, Annual Radiological Environmental Operating Report for Calendar Year 20052006-04-18018 April 2006 Annual Radiological Environmental Operating Report for Calendar Year 2005 L-2005-095, Annual Environmental Operating Report2005-04-26026 April 2005 Annual Environmental Operating Report L-2005-069, Annual Radiological Environmental Operating Report for Calendar Year 20042005-03-31031 March 2005 Annual Radiological Environmental Operating Report for Calendar Year 2004 L-2005-038, 2004 Annual Radioactive Effluent Release Report2005-02-28028 February 2005 2004 Annual Radioactive Effluent Release Report L-2005-037, Letter Transmitting, St. Lucie Units 1 and 2, 2004 Annual Overating Report2005-02-28028 February 2005 Letter Transmitting, St. Lucie Units 1 and 2, 2004 Annual Overating Report L-2004-081, Annual Radiological Environmental Operating Report2004-04-13013 April 2004 Annual Radiological Environmental Operating Report L-2004-070, Annual Environmental Operating Report2004-04-13013 April 2004 Annual Environmental Operating Report L-2004-012, Transmittal of the 2003 Annual Operating Report2004-02-12012 February 2004 Transmittal of the 2003 Annual Operating Report 2023-09-20
[Table view] Category:Letter type:L
MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2024-004, Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years2024-01-18018 January 2024 Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years L-2024-002, Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2024-01-0808 January 2024 Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-173, Quality Assurance Topical Report (FPL-1) Revision 30 Update2023-12-15015 December 2023 Quality Assurance Topical Report (FPL-1) Revision 30 Update L-2023-179, Unusual or Important Environmental Event - Turtle Mortality2023-12-14014 December 2023 Unusual or Important Environmental Event - Turtle Mortality L-2023-168, License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 52023-12-12012 December 2023 License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 5 L-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-162, Response to 50.69 2nd Round of Rals2023-11-21021 November 2023 Response to 50.69 2nd Round of Rals L-2023-131, Subsequent License Renewal Application - Second Annual Update2023-09-28028 September 2023 Subsequent License Renewal Application - Second Annual Update L-2023-136, Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-26026 September 2023 Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-122, Corrections to the 2022 Annual Radiological Environmental Operating Report2023-09-20020 September 2023 Corrections to the 2022 Annual Radiological Environmental Operating Report L-2023-127, Correction to the 2022 Annual Radioactive Effluent Release Report2023-09-18018 September 2023 Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-113, Correction to the 2020 Annual Radiological Environmental Operating Report2023-09-14014 September 2023 Correction to the 2020 Annual Radiological Environmental Operating Report L-2023-118, Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-11011 September 2023 Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-108, Report of 10 CFR 50.59 Plant Changes2023-09-11011 September 2023 Report of 10 CFR 50.59 Plant Changes L-2023-112, Corrections to the 2021 Annual Radioactive Effluent Release Report2023-09-0606 September 2023 Corrections to the 2021 Annual Radioactive Effluent Release Report L-2023-107, Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.42023-09-0606 September 2023 Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.4 L-2023-114, Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update2023-08-17017 August 2023 Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-105, Preparation and Scheduling of Operator Licensing Examinations2023-08-0303 August 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-099, Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2023-07-26026 July 2023 Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-102, Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches2023-07-26026 July 2023 Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches L-2023-097, Subsequent License Renewal Application Revision 1 - Supplement 62023-07-13013 July 2023 Subsequent License Renewal Application Revision 1 - Supplement 6 L-2023-076, In-Service Inspection Program Owner'S Activity Report (OAR-1)2023-07-11011 July 2023 In-Service Inspection Program Owner'S Activity Report (OAR-1) L-2023-087, Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452)2023-06-29029 June 2023 Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452) L-2023-082, Subsequent License Renewal Application Revision 1, Supplement 52023-06-14014 June 2023 Subsequent License Renewal Application Revision 1, Supplement 5 L-2023-074, Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update2023-06-0202 June 2023 Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update L-2023-071, NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal2023-05-22022 May 2023 NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal L-2023-059, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 4 Supplemental Response2023-04-21021 April 2023 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 4 Supplemental Response L-2023-055, 2022 Annual Environmental Operating Report2023-04-12012 April 2023 2022 Annual Environmental Operating Report L-2023-041, Annual Radiological Environmental Operating Report for Calendar Year 20222023-04-0404 April 2023 Annual Radiological Environmental Operating Report for Calendar Year 2022 L-2023-051, Report of 10 CFR 50.59 Plant Changes2023-04-0404 April 2023 Report of 10 CFR 50.59 Plant Changes L-2023-021, Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2023-03-28028 March 2023 Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2023-042, Periodic Update of Population Data within 10 and 50 Miles of the Plant2023-03-27027 March 2023 Periodic Update of Population Data within 10 and 50 Miles of the Plant L-2023-026, Subsequent License Renewal Application - Aging Management Requests for Additional Information Set 42023-03-27027 March 2023 Subsequent License Renewal Application - Aging Management Requests for Additional Information Set 4 L-2023-028, and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2023-03-27027 March 2023 and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2023-025, Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-12023-03-15015 March 2023 Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-1 L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2023-039, Cycle 27 Core Operating Limits Report2023-03-0707 March 2023 Cycle 27 Core Operating Limits Report L-2023-032, 2022 Annual Radioactive Effluent Release Report2023-02-28028 February 2023 2022 Annual Radioactive Effluent Release Report L-2023-038, 2022 Annual Operating Report2023-02-28028 February 2023 2022 Annual Operating Report L-2023-016, Radiological Emergency Plan - Revision 74 Report of Changes to Emergency Plan2023-02-15015 February 2023 Radiological Emergency Plan - Revision 74 Report of Changes to Emergency Plan L-2023-019, Annual Summary of Commitment Changes Implemented Without Prior NRC Notification for Calendar Year 20222023-02-15015 February 2023 Annual Summary of Commitment Changes Implemented Without Prior NRC Notification for Calendar Year 2022 L-2023-009, Owner'S Activity Report2023-01-31031 January 2023 Owner'S Activity Report L-2022-188, Unusual or Important Environmental Event - Turtle Mortality2022-12-19019 December 2022 Unusual or Important Environmental Event - Turtle Mortality L-2022-185, Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-12-0909 December 2022 Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2022-175, Application to Adopt 10 CPR 50.69, 'Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2022-12-0202 December 2022 Application to Adopt 10 CPR 50.69, 'Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2022-180, CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2022-11-0909 November 2022 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2022-165, Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) 4.3.1-1a(second Round) - Class 1 Fatigue Response2022-10-26026 October 2022 Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) 4.3.1-1a(second Round) - Class 1 Fatigue Response L-2022-160, Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-10-0404 October 2022 Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 2024-01-08
[Table view] |
Text
II Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 0 December'5, 2006 FPL L-2006-263 10 CFR 50.59 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: St. Lucie Unit 2 Docket No. 50-389 Report of 10 CFR 50.59 Plant Changes Pursuant to 10 CFR 50.59(d)(2), the attached report contains a brief description of any changes, tests, and experiments, including a summary of the 50.59 evaluation of each which were made on Unit 2 during the period of February 15, 2005 through June 12, 2006. This submittal correlates with the information included in Amendment 17 of the Updated Final Safety Analysis Report submitted under separate cover.
Please contact us should there by any questions regarding this information.
Very truly yours, GLJ/tlt Attachment an FPL Group company q7
ST. LUCIE UNIT 2 DOCKET NUMBER 50-389 CHANGES, TESTS AND EXPERIMENTS MADE AS ALLOWED BY 10 CFR 50.59 FOR THE PERIOD OF FEBRUARY 15, 2005 THROUGH JUNE 12, 2006 1
INTRODUCTION This report is submitted in accordance with 10 CFR 50.59 (d)(2), which requires that:
i) changes in the facility as described in the SAR; ii) changes in procedures as described in the SAR; and iii) tests and experiments not described in the SAR that are conducted without prior Commission approval be reported to the Commission in accordance with 10 CFR 50.90 and 50.4. This report is intended to meet these requirements for the period of February 15, 2005 through June 12, 2006.
This report is divided into three (3) sections. First, changes to the facility as described in the Updated Final Safety Analysis Report (UFSAR) performed by a Plant Change/Modification (PC/M). Second, changes to the facility/procedures as described in the UFSAR, or tests/experiments not described in the UFSAR, which are not performed by a PC/M. Third, a summary of any fuel reload 50.59 evaluation.
Each of the documents summarized in Sections 1,2 and 3 includes a 10 CFR 50.59 evaluation that evaluated the specific change(s). Each of these 50.59 evaluations concluded that the change does not require a change to the plant technical specifications, and that prior NRC approval is not required.
2
TABLE OF CONTENTS SECTION 1 PLANT CHANGE/MODIFICATIONS PAGE 05034 Feedwater Control Replacement - Phase 2 5 SECTION 2 50.59 EVALUATIONS PAGE SENS-00-013 Use of PRC-01 Resin to Remove Co-58 7 Contaminants SECJ-04-064 Cask Crane Main Hoist Weight Limit Increase 8 to 150 Tons SENS-06-038 Fuel Handling Building Placement of Tri- 9 Nuclear FilterNacuum Above Spent Fuel Racks for Spent Fuel Pool Cleanup SECTION 3 RELOAD EVALUATION PAGE 05197 St Lucie Unit 2 Cycle 16 Reload 11 3
SECTION 1 PLANT CHANGE / MODIFICATIONS 4
PLANT CHANGEIMODIFICATION 05034 REVISION 0 FEEDWATER CONTROL REPLACEMENT - PHASE 2 Summary:
This modification upgrades the existing Feedwater Regulating System (FWRS), Steam Bypass Control System (SBCS), and the Reactor Coolant Pump (RCP) monitoring and display system with new Distributed Control System (DCS) equipment and software.
The new DCS equipment will interface with the installed DCS and Plant Data Network.
A new version of software, version 8.0, has been developed and migrated over to the existing DCS to improve system performance.
This modification upgrades the ABB controllers FIC-9011/9021 located on Reactor Turbine Generator Board (RTGB) 202 with DCS compatible touch screen manual/auto (M/A) stations. Ten RTGB 202 indicators and six RTGB 202 recorders associated with the Feedwater and sixty RCP indicators on RTGB 203 are being replaced with Flat Panel Displays (FPDs).
A new cabinet (ALC-6) was installed in the cable spreading room. The cabinet houses a new control processor, field-bus modules, baseplates and power supplies to interface with the annunciator logic cabinets.
The reason for this modification was to reduce the instability (oscillations) of the FWRS and to upgrade this control system along with the SBCS Steam Dump to Condenser Valve controls and the RCP monitoring and display system to a DCS. The existing Low Power Feedwater 15% Bypass Control Valves and SBCS Steam Dump to Condenser Valve pneumatic positioners were replaced with digital positioners to enhance tuning and diagnostic capability.
5
SECTION 2 50.59 EVALUATIONS 6
EVALUATION SENS-00-013 REVISION 4 USE OF PRC-01 RESIN TO REMOVE CO-58 CONTAMINANTS Summary:
Revisions 0, 1 and 2 were identified in the 50.59 summary report issued in 2002.
Revision 3 was identified in the 50.59 summary report issued in 2005. Revision 4 was approved in 2006 and is thus included in this report.
This evaluation was prepared to examine the use of PRC-01 resin material in the chemical and volume control system (CVCS) letdown demineralizers without mode restrictions and extends authorized use to the Fuel Pool Ion Exchanger.
Revision 1 made minor modifications to the plant restrictions provided previously, to add and more precisely paraphrase UFSAR text and to include an additional required action related to calibration of the CVCS ion exchanger bypass valve.
Revision 2 provided a basis for extending use of PRC-01 resin to any condition where the effective neutron multiplication factor is less than 1.0, consistent with the plant restrictions identified herein. Revision 2 also incorporated format and content changes necessary to comply with the changes to 10 CFR 50.59.
Revision 3 removed a requirement that the PRC-01 resin must be taken out of service when hydrogen peroxide concentration in the RCS is greater than 5 ppm. This requirement was originally provided to conservatively reduce exposure of the resin to oxidizing environments. Laboratory testing and subsequent plant experience indicates this restriction is not required when plant chemistry is maintained in accordance with EPRI guidelines. Revision 3 also provided some minor administrative documentation changes.
Revision 4 extends use of PRC-01 resin in the demineralizers in the CVCS letdown subsystem when the reactor is critical and extends authorized use of PRC-01 to the Fuel Pool Ion Exchanger. The online restriction in CVCS use was initially provided as one of a number of restrictions governing the first use of PRC-01 resin at St. Lucie.
Subsequent plant experience indicates this restriction is not required to maintain plant chemistry in accordance with EPRI guidelines. Extension of PRC-01 use to the Fuel Pool Ion Exchanger will provide additional water clarity and is consistent with use at Turkey Point and other plants. In addition, a number of other more minor changes are made to align St. Lucie's more restrictive first-use procedure with current vendor guidance.
7
EVALUATION SECJ-04-064 REVISIONS 0 & 1 CASK CRANE MAIN HOIST WEIGHT LIMIT INCREASE TO 150 TONS Summary:
The cask handling cranes at St. Lucie Units 1 and 2 have been replaced with new single-failure-proof cask cranes of greater capacity. The new cranes have a 150 ton single-failure-proof main hoist and a conventional 25 ton auxiliary hoist.
The purposes of this evaluation are to increase the main hoist load limit to the maximum critical load capacity of the new main hoist (150 tons); expand the main hoist safe load path to include all the area that is accessible to the main hoist; and permit the main hoist to place the cask lid on the cask when the cask contains spent fuel.
The main hoist load increase and expanded safe load path are not limited to spent fuel casks. Load transport safety does not depend on the load shape or composition.
Therefore, the main hoist may be used to transport other loads of up to 150 tons within the area accessible to the main hoist.
For the purpose of this evaluation, placing the lid on the cask includes lowering the lid onto the cask and/or lifting the lid off the cask. (This recognizes the possibility that it may be desired to raise the lid after it has been set on the cask.)
The main hoist load limit was increased by revising Unit 2 UFSAR Sections 9.1.4.1.2.2 and 13.7.1.8 through 13.7.1.8.2. The main hoist load path was expanded by revising the heavy loads procedure, AP-0010438. The main hoist permissive to place the cask lid on the cask when the cask contains spent fuel is provided by revising Unit 2 UFSAR Section 13.7.1.7.1 and the heavy loads procedure, AP-0010438.
Revision 1 incorporates updated references.
8
EVALUATION SENS-06-038 REVISIONS 0 & 1 FUEL HANDLING BUILDING PLACEMENT OF TRI-NUCLEAR FILTER/VACUUM ABOVE SPENT FUEL RACKS FOR SPENT FUEL POOL CLEAN-UP Summary:
Water in the spent fuel pool (SFP) was exhibiting a high level of turbidity, a condition that will hinder the movement of fuel assemblies in the pool. To alleviate this condition a Tri-Nuclear filter/vacuum system was placed in the SFP to filter the pool water. The filter/vacuum equipment was attached to existing handrail support posts and suspended in the pool above the storage racks.
Revision 1 was issued to add discussion regarding the potential for the filter/vacuum to drop and land flush on one or more spent fuel assemblies.
9
SECTION 3 RELOAD EVALUATION 10
PLANT CHANGE/MODIFICATION 05197 REVISIONS 0 ST. LUCIE UNIT 2 CYCLE 16 RELOAD Summary:
This engineering package provides the reload core design for St. Lucie Unit 2 Cycle 16 developed by Florida Power & Light Company (FPL) and Westinghouse Electric -
Combustion Engineering (W-CE). The Cycle 16 core was designed for a nominal cycle length of 11,240 EFPH, based on a nominal Cycle 15 length of 10,200 EFPH. The Cycle 16 reload design supports an additional end-of-cycle coastdown length of 360 EFPH with a maximum reduction in primary coolant inlet temperature to 535 degrees F.
The primary design change to the core for Cycle 16 was the replacement of 77 irradiated fuel assemblies with 72 fresh Region T assemblies and 4 irradiated Region P fuel assemblies and 1 Region S assembly currently residing in the spent fuel pool. The fuel in the Cycle 16 core was arranged in a low leakage pattern. The mechanical design of the Region U fuel is essentially the same as that of the Region T fuel, and consists of "value-added" fuel pellets and the "guardian grid" design, first introduced in Cycle 11. The only significant difference is that Region U incorporates an Inconel top grid to mitigate grid-to-rod fretting failures observed at this unit in recent cycles.
The implementation instructions provided in this modification support a full core off-load. The safety analysis of this design was performed by W-CE and by FPL using NRC approved methodologies.
The Cycle 16 reload analysis supports a maximum steam generator tube plugging level of 2520 tubes per steam generator (30% average) with a maximum asymmetry of 600 tubes between the two steam generators, and a minimum reactor coolant system (RCS) flow of 335,000 gpm. Additionally, the Cycle 16 reload analysis supports the replacement of the circuit cards for the RCS Low Flow Trip transmitters to add a variable dampening feature, which will increase the total response time from 0.65 second up to 0.90 second.
11