Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.

James A Fitzpatrick NPP

"--"-gy Lycoming, NY 13093 Tel 315 349 6024 Fax 315 349 6480 T.A. Sullivan Vice President, Operations-JAF November 12, 2002 JAFP-02-02 10 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Stop O-P1-17 Washington, DC 20555-0001

SUBJECT:

James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 10 CFR 50.46 Reporting of Changes In Emergency Core Cooling System (ECCS) Evaluation Model

Dear Sir:

In accordance with 10 CFR 50.46 (a) (3) (ii), this submittal is provided to report a change in the Emergency Core Cooling System (ECCS) evaluation as a result of a change in fuel design use at FitzPatrick.

The plant recently completed Refueling Outage 15, and began Cycle 16 operations utilizing both General Electric 14 type fuel (GE14) and General Electric 12 type fuel (GE12). GEl2 has been used during the previous three operating cycles.

The Licensing Basis peak clad temperature (PCT) calculated for GE14 is 17000 Fahrenheit (F),

increasing the previous calculated PCT value by 160°F. PCT calculations for GEl2/GEl4 are based on the same NRC approved GE methods. The PCT increase is a result: (1) higher Linear Heat Generation Rate (LHGR) for GE14; (2) lower assumed Core Spray System flow rate; and (3) a wider band of operating conditions including Maximum Extended Loadline Limit Analysis and Final Feedwater Temperature reduction.

Since the PCT for GE14 is well below the 2200'F requirements of 10 CFR 50.46(b)(1), there is no need for re-analysis or other action per 10 CFR 50.46(a)(3)(ii). Other 10 CFR 50.46(b) criteria are met for the GE14.

- &.ý' 1 No new commitments are contained in this letter. Should you have any questions, please direct them to Mr. William Drews at (315) 349-6562.

V*2ruiY yours,.

T. A. SullivanU Vice President, Operations TAS:GB cc: Regional Administrator U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. Guy Vissing, Project Manager Project Directorate 1 Division of Licensing Project Management U.S. Nuclear Regulatory Commission Washington, DC 20555 Office of the Resident Inspector James A. FitzPatrick Nuclear Power Plant U.S. Nuclear Regulatory Commission P.O. Box 136 Lycoming, NY 133093