IR 05000528/1998099

From kanterella
Jump to navigation Jump to search
Errata to Page 5 W/Clarifcation for Plant Support Functional Area for SALP Repts 50-528/98-99,50-529/98-99 & 50-530/98-99 on 960602-980307
ML17313A539
Person / Time
Site: Palo Verde  
Issue date: 04/08/1998
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML17313A537 List:
References
50-528-98-99, 50-529-98-99, 50-530-98-99, NUDOCS 9808180206
Download: ML17313A539 (4)


Text

Arizona Public Service Company-5-Overall, performance in the emergency preparedness area was good.

While performance during the evaluated exercise was satisfactory, two weaknesses were identified: one for failing to promptly recognize and declare a Notification of Unusual Event; and, one for failing to notify offsite agencies of a protective action recommendation upgrade.

The initial emergency exercise scenario was only minimally challenging, and the exercise scenario package submitted to the NRC was incomplete.

In addition, the inventorying and control of emergency equipment, and the submission of changes to the site Emergency Plan were areas where improvement could be realized.

Personnel were trained in accordance with the Emergency Plan and overall, emergency response facilities were properly maintained.

Those program changes which were approved were appropriately incorporated into the Emergency Plan and procedures.

The licensee's fire fighting capability remained an area of strength.

This was attributed, in part, to the full-time fire department which is maintained at the site. fire drills were effectively conducted, and when an actual fire (caused by the overheating of a nonsafety-related inverter) occurred in July 1996, the fire brigade responded well. The improvements noted in housekeeping and the control of transient combustibles were attributed to the improvements made in defining area ownership within the Zone Improvement Program.

To assure integrity of fire barriers, the licensee completed a re-evaluation and analysis of all the barriers.

The level of plant and radiological housekeeping improved throughout the assessment period.

While inconsistent housekeeping standards were noted in different areas of the site, the deficiencies were minor in nature.

Overall, housekeeping was very good.

Problem identification and analysis were strong.

In the radiological protection and security areas, quality assurance oversight was excellent, and corrective actions were effective and timely; however, problem identification and correction were not as effective in the emergency preparedness area.

The post-exercise and management critiques of the biennial exercise tended to focus only on strengths and positive findings, and they were not effective in identifying issues that needed corrective action or areas for improvement.

In contrast, the Nuclear Assurance Department's emergency preparedness audits did identify several areas where corrective actions effectiveness could be improved.

Overall, performance in the Plant Support functional area was determined to be Category 1, 9808'L80206 9808'L2 Pan naaCX oa000m8

PDR

I I

I

Arizona Public Service Company-7-AUG j 2 l998 E-Mail report to T. Frye (TJF)

E-Mail report to D. Lange (DJL)

E-Mail report to NRR Event Tracking System (IPAS)

E-Mail report to Document Control Desk (DOCDESK)

E-Mail report to R. Correia (RPC)

E-Mail report to F. Talbot (FXT)

bcc to DCD (IE40)

Resident Inspector DRS-PSB MIS System RIV File B. Henderson (PAO)

C. Gordon Records Center, INPO Deputy Regional Administrator SRls at all RIV sites C. A. Hackney B. Murray, DRS/PSB bcc distrib. by RIV:

Regional Administrator DRP Director Branch Chief (DRP/D, WCFO)

Senior Project Inspector (DRP/D)

Branch Chief (DRP/TSS)

WCFO File The Chairman (MS: 16-G-15)

Commissioner Rogers (MS: 16-G-15)

Commissioner Diaz Commissioner McGaffigan L. J. Callan, EDO (MS: 17-G-21)

Associate Dir. for Projects, NRR Associate Dir. for Insp., and Tech. Assmt, NRR SALP Program Manager, NRR/ILPB (2 copies)

J. W. Roe, NRR, Director, Division of Reactor Projects III/IV M. B. Fields, NRR, Project Manager DOCUMENT NAME: R:QPNPV899AK2.KEB To receive co of document, Indicate In box: "C" = Co without enclosures

"E" = Co viith enclosures "N ~ No co RIV:DD:DRP E D:DRS E

NRR E

RA KEBro man

~

8/

WHBateman EW e

off ATHowell 7/10/98 er e-mail 7/11/98 er telecon 8/I OFFICIAL RECORD COPY