IR 05000461/2024011

From kanterella
Jump to navigation Jump to search
Commercial Grade Dedication Inspection Report 05000461/2024011
ML24253A036
Person / Time
Site: Clinton Constellation icon.png
Issue date: 09/09/2024
From: Karla Stoedter
NRC/RGN-III/DORS/EB1
To: Rhoades D
Constellation Energy Generation
References
IR 2024011
Download: ML24253A036 (1)


Text

SUBJECT:

CLINTON POWER STATION - COMMERCIAL GRADE DEDICATION INSPECTION REPORT 05000461/2024011

Dear David P. Rhoades:

On August 30, 2024, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Clinton Power Station and discussed the results of this inspection with Andrew Krakowski, Plant Manager and other members of your staff. The results of this inspection are documented in the enclosed report.

One finding of very low safety significance (Green) is documented in this report. This finding involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.

If you contest the violation or the significance or severity of the violation documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region III; the Director, Office of Enforcement; and the NRC Resident Inspector at Clinton Power Station.

If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region III; and the NRC Resident Inspector at Clinton Power Station.

September 9, 2024 This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Karla K. Stoedter, Chief Engineering Branch 1 Division of Operating Reactor Safety Docket No. 05000461 License No. NPF-62

Enclosure:

As stated

Inspection Report

Docket Number:

05000461

License Number:

NPF-62

Report Number:

05000461/2024011

Enterprise Identifier:

I-2024-011-0031

Licensee:

Constellation Nuclear

Facility:

Clinton Power Station

Location:

Clinton, IL

Inspection Dates:

May 20, 2024 to August 30, 2024

Inspectors:

M. Gangewere, Reactor Inspector

B. Jose, Senior Reactor Inspector

A. Valiaveedu, Reactor Inspector

Approved By:

Karla K. Stoedter, Chief

Engineering Branch 1

Division of Operating Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a commercial grade dedication inspection at Clinton Power Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

Failure to Establish Procedure Controls to Perform Commercial Grade Dedication Activities of Components Installed on Safety Related Equipment Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000461/2024011-01 Open/Closed

[H.9] - Training 71111.21N.03 The inspectors identified a finding of very low safety significance (Green) and an associated non-cited violation (NCV) of Title 10 of the Code of Federal Regulations (10 CFR) Part 50,

Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to ensure activities affecting quality were prescribed by documented instructions and procedures appropriate to the circumstance. Specifically, the licensee failed to ensure the instructions prescribed in Procedure SM-AA-102, Attachment 4, Exhibit 1, Quality Receipt Inspection Package, appropriately verified the critical characteristics of commercially purchased items while dedicating the items for installation in safety related applications. This led to commercial items being installed on safety related equipment prior to completing required dedication activities.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

===71111.21N.03 - Commercial Grade Dedication The inspectors reviewed the implementation of the licensees process for dedicating commercial-grade items (CGI) as basic components and for procuring safety-related components for the following samples:

Commercial Grade Dedication===

(1) Catalog Id: 5704; Circuit Board, 125 Vdc Battery Charger
(2) Catalog Id: 6447; Cap for 1/2" Stainless Steel Tube
(3) Catalog Id: 9110; Rebuild/Repair Kit for Norogren In-Line Lubricator Used in Emergency Diesel Generators (EDGs)
(4) Catalog Id: 9703; 5/8: Copper Tube Adapter Used in Various Chillers
(5) Catalog Id: 10146; 480 V Molded Case Circuit Breaker
(6) Catalog Id: 27021; 120/24 Vac Step Down Control Power Transformer
(7) Catalog Id: 43003, Masonry Mortar for Wall Repairs
(8) Catalog Id: 247670; Stainless Steel Filter Housing for Refrigeration Unit
(9) Catalog Id: 48156; 3" Flexible Wedge Valve Disk with Stellite
(10) Catalog Id: 34975; EDG Crank Case Pressure Switch (11)48160; Ethylene Propylene 0.925" Internal Diameter and 0.116" Width O-Ring Used in Various Applications
(12) Catalog Id: 1100595; 4500 Micro Farad Aluminum Can Electrolytic Capacitor Used in 125 Vdc Battery Chargers
(13) Catalog Id: 829; Valve Stem Assembly for Air Start Valve on EDGs
(14) Catalog Id: 3659; Lower Ball Bearing for Connecting Rod on EDGs
(15) Catalog Id: 1066;125 Vdc General Electric Auxiliary Relay Used in Various Protective Relaying Schemes

INSPECTION RESULTS

Failure to Establish Procedure Controls to Perform Commercial Grade Dedication Activities of Components Installed on Safety Related Equipment Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000461/2024011-01 Open/Closed

[H.9] - Training 71111.21N.03 The inspectors identified a finding of very low safety significance (Green) and an associated non-cited violation (NCV) of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to ensure activities affecting quality were prescribed by documented instructions and procedures appropriate to the circumstance. Specifically, the licensee failed to ensure the instructions prescribed in Procedure SM-AA-102, Attachment 4, Exhibit 1, Quality Receipt Inspection Package, appropriately verified the critical characteristics of commercially purchased items while dedicating the items for installation in safety related applications. This led to commercial items being installed on safety related equipment prior to completing required dedication activities.

Description:

The inspectors reviewed commercial grade dedication (CGD) documentation of a copper tube adapter, catalog ID (CID) 9703-2, which was installed on the safety related control room HVAC Chiller B, 0VC13CB, under work order (WO) 7077714-01. The inspectors reviewed associated procurement evaluation 70559 which identified the following critical characteristics that were required to be verified using a reduced sampling scheme as part of the quality receipt inspection/commercial grade dedication process. The verification of critical characteristics provides reasonable assurance the commercial item will perform its intended safety function:

  • Provide visual assurance that the fitting matches the requirements set forth in American Society of Mechanical Engineers Code B16.22-2001.
  • Verification the item is copper (minimum 84 percent copper and maximum 16 percent zinc) which provides assurance the item is fabricated from a material that supports an effective brazing or solder joint and will maintain the pressure boundary function.
  • Measuring the tubing connection dimensions which provides assurance the fitting fits the application and maintains its pressure boundary function.

The inspectors reviewed purchase order 00805131 and quality receipt inspection (RIN)package 00196404 and were unable to conclude the critical characteristics were verified to ensure the commercial grade tube adapters would perform their intended safety function. The licensee initiated a corrective action document, Action Request (AR) 04776142, and concluded the required testing was not performed at the time of the quality receipt inspection.

Dedication testing of the remaining stock that had not been installed was performed at PowerLabs satisfactorily.

The licensee determined the Quality Control (QC) level II receipt inspector who completed the receipt inspection was a contractor filling in at the time. The licensee performed an extent of condition review and identified 39 CIDs had been installed in 55 unique equipment identification numbers in the plant without the associated verification of critical characteristics being performed. A total of 27 ARs were initiated for all affected CIDs that were installed in the plant. Operations performed an operability or functionality review for all 55 unique equipment identification numbers and determined there were no impacts to plant equipment.

The site also identified two additional QC level II receipt inspectors, who were also contractors, had not performed the required critical characteristic verification as part of the quality receipt inspection process.

Step 1.3.1 of Procedure SM-AA-102, Attachment 4, Receipt of Items, directed personnel to complete all necessary quality receipt inspection reports including, VERIFYING Commercial Grade Item dedication activities in accordance with the dedication verification plan, by using Exhibit 1, Quality Receipt Inspection Package. The inspectors reviewed SM-AA-102, 4, Exhibit 1 and found it failed to include instructions or steps to verify CGD activities, including the verification of critical characteristics, in accordance with the dedication verification plan. The licensee's corrective action program evaluation (CAPE) performed under AR 4778626 also found CGD activities were not listed as a specific item on Exhibit 1.

The licensee planned to revise Exhibit 1 to ensure a completed copy of the dedication plan and the requirement to verify critical characteristics of commercially dedicated items was included in the receipt package.

Additionally, the inspectors reviewed training documents and certification records of the QC level II receipt inspectors who had failed to properly dedicate the commercially purchased items. Specifically, the inspectors reviewed training module SM-G-03, Receipt Inspector Training Program, and found it did not include an objective specific to CGD activities. In conjunction with this lesson plan, the inspectors also found Step 4.2.5.3 of Procedure SM-AA-101, Certification of Receipt Inspectors, Revision 12 required on-the-job training for a receipt inspector to become 100 percent proficient in receipt inspection tasks. Upon review of the three contracted personnels completed certification recorded on SM-AA-101, 5, On-the-Job Training for Receipt Inspectors, the inspectors noted the recorded CGD on-the-job hours ranged from one to two hours. Additionally, the receipt inspection documentation credited for these hours included safety-related equipment procurements rather than commercially dedicated items. The lack of documented CGD training, in addition to the lack of CGD instructions on SM-AA-102, Attachment 4, Exhibit 1, led the inspectors to conclude procedural controls for consistently performing quality receipt inspections of CGD components were not appropriate to the circumstance.

Corrective Actions: The licensee entered this issue into their corrective action program and performed an extent of condition review of all CGDs performed by contracted QC support personnel from August 2020 through June 2022. Corrective action documents were generated for all items that had receipt inspection deficiencies. Operations performed operability or functionality reviews as appropriate. Additionally, catalog IDs which had not been properly dedicated for use were placed on hold to prevent their issuance pending the verification of critical characteristics. The licensee also planned to revise SM-AA-102, 4, Exhibit 1, Part III to add a step for CGD activities.

Corrective Action References: ARs 4776142, 4777518, 4777520, 4777523, 4777528, 4777535, 4777537, 4777539, 4777542, 4777546, 4777549, 4777552, 4777553, 4777554, 4777556, 4777557, 4777560, 4777826, 4777833, 4777836, 4777838, 4777839, 4777840, 4777842, 4777845, 4777858, 4778588, 4778590, 4778593, and 4778626.

Performance Assessment:

Performance Deficiency: The licensees failure to prescribe documented instructions and procedures of a type appropriate to the circumstances for performing the CGD of commercially purchased items prior to their installation in safety-related applications, an activity affecting quality, was contrary to 10 CFR 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, and was a performance deficiency.

Screening: The inspectors determined the performance deficiency was more than minor because if left uncorrected, it would have the potential to lead to a more significant safety concern. Specifically, the failure to ensure procedural controls for performing CGDs were appropriate to the circumstance would allow commercially purchased items to continue being installed in safety related equipment without ensuring the item could perform its safety functions.

Significance: The inspectors assessed the significance of the finding using IMC 0609 Appendix A, The Significance Determination Process (SDP) for Findings At-Power.

Specifically, the inspectors determined the finding was of very low safety significance (Green)because the operability or functionality of the commercially purchased items and the equipment each item was installed in was maintained.

Cross-Cutting Aspect: H.9 - Training: The organization provides training and ensures knowledge transfer to maintain a knowledgeable, technically competent workforce and instill nuclear safety values. Specifically, the licensee's current training program did not ensure commercial grade dedications were consistently completed, the certification of quality control level II receipt inspectors was adequate, the warehouse supervisor responsible for oversight of the contractor work was knowledgeable of CGD requirements.

Enforcement:

Violation: Title 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, requires, in part, that activities affecting quality shall be prescribed by documented instructions, procedures, or drawings, of a type appropriate to the circumstances and shall be accomplished in accordance with these instructions, procedures or drawings.

The licensee established Procedure, SM-AA-102, Attachment 4, Exhibit 1, Quality Receipt Inspection Package, as the implementing procedure which provided instructions for completing CGD activities, including the verification of critical characteristics, of commercially purchased items intended for use in safety related applications, an activity affecting quality.

Contrary to the above, as of August 30, 2024, the licensee failed to ensure activities affecting quality were prescribed by documented instructions, procedures, or drawings appropriate to the circumstance. Specifically, SM-AA-102, Attachment 4, Exhibit 1 failed to include instructions to ensure the critical characteristics of commercially purchased items were verified as part of the CGD process.

Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On August 30, 2024, the inspectors presented the commercial grade dedication inspection results to Andrew Krakowski, Plant Manager and other members of the licensee staff.
  • On June 7, 2024, the inspectors presented the commercial grade dedication interim inspection results to Norha Plumey, Site Vice President and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

287793

NOS ID Gap ID'd in Wall in the Aux Electrical Equipment

Room

10/14/2019

Corrective Action

Documents

290966

NOS ID: NOS Finding for Fire Protection for Fire Zone

CB-3

10/24/2019

04775893

Quality Material Staging Verification

05/22/2024

04776142

NRC Id'd - Commercial Grade Dedication Issue for Fitting

05/23/2024

04777518

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777520

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777523

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777528

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777535

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/20/2024

04777537

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777539

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777542

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777546

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777549

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777552

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777553

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

71111.21N.03

Corrective Action

Documents

Resulting from

Inspection

04777554

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

04777556

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777557

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777560

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/30/2024

04777826

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04777833

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04777836

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04777838

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04777839

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04777840

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04777842

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04777845

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04777858

NRC Id'd-Commercial Grade Dedication Extent of

Condition

05/31/2024

04778377

NRC ID'd Parts Staged Without Expected Return Date on

Sign

06/03/2024

04778588

NRC Id'd-Commercial Grade Dedication Extent of

Condition

06/04/2024

04778590

NRC Id'd-Commercial Grade Dedication Extent of

Condition

06/04/2024

04778593

NRC Id'd-Commercial Grade Dedication Extent of

Condition

06/04/2024

04778626

Trend IR: Commercial Grade Dedication Extent of

Condition

06/04/2024

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

04778654

NRC Id'd - Dynamic Screening Form not Included per

Procedure

06/04/2024

04778668

NRCID: Incorrect Cal. Tolerance in PMRQ 00150336-01

Scope

06/04/2024

04778753

NRC ID'd-Storage of Q-3 Parts in Refrigerator

06/05/2024

04779047

NRC ID'd-Concern with Disc Valves in Inventory

06/06/2024

04787535

CAPE 4778626 Extent of Condition

07/16/2024

Engineering

Changes

ECR 444029

Repair Plan for Gaps and Voids in Framed Opening 1-81

Ref IR 4287793

05/13/2020

CGICF01

EPRI CGI Joint Utility Task Group Commercial Grade Item

Evaluation for Compression Fittings

M-1995-610-0

SI 783E73, Carrier Filter Housing

10/09/1995

M-1998-0228-

001

Evaluation for Fittings for Chiller

2/24/1998

M-91-003-0161-

Evaluation Topic Relationship Report: Assembly of

Masonry Units

06/23/1997

NSED Review

34515

EMD Stem Assembly for Air Start Valves

Technical/Quality Requirements

03/01/1986

PE 00005575

Procurement Evaluation for Mortar, Masonry, Construction

Grade, Per ASTM C-270 Type M - Cat ID 43003-2

04/04/2000

PE 00037525

Procurement Evaluation for Adapter, Tube, 5/8 in.

Nominal Solder Joint x 3/4 in. Male NPT, Copper - Cat ID

9703-2

01/27/2005

PE 00038662

Procurement Evaluation Connectng Rod Lower Bearing

03/25/2005

PE 00046146

Procurement Evaluation for High Crankcase Pressure

Switch - Cat ID 0001106887-1

09/13/2005

PE 00046370

Procurement Evaluation for High Crankcase Pressure

Switch - Cat ID 0001106887-1

09/21/2005

PE 00054471

Procurement Evaluation for Fuel, DIesel, No. 2-D, S15,

Per ASTM D (75-06B, Ultra Low Sulfur Diesel Fuel

01/15/2007

PE 00067004

Procurement Evaluation for Tee, Tubing, Union, 1/4" Tube

x 1/4" Tube x 1/4" Tube, Brass, ASTM B283

10/15/2009

Engineering

Evaluations

PE 00070559

Procurement Evaluation for Adapter, Tube, 5/8 in.,

Nominal Solder Joint x 3/4 in. Male NPT, Copper - Cat ID

11/09/2010

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

9703-2

PE 00073670

Procurement Evaluation Tubing Cap

10/05/2011

PE 00081314

Procurement Evaluation for Housing, Filter, Model CT

2, Brass Head/SS Sump, for Refrigeration Unit

08/06/2013

PE 00081367

Procurement Evaluation for Housing, Filter, Model CT

2, Brass Head/SS Sump, for Refrigeration Unit - Cat ID

247670-2

08/15/2013

PE 00081909

Procurement Evaluation for Housing, Filter, Model CT102,

SS Head/SS Sump, for Refrigeration Unit - Cat ID

0000247670-2

04/07/2014

PE 00090924

Procurement Evaluation for Bearing, Ball, Single Row

Deep Groove, 110 MM

10/14/2015

PE 00094277

Procurement Evaluation for Pressure Gauge, 0-100 PSIG

08/02/2016

PE 00102304

Procurement Evaluation for Tube Assembly, Electrical,

GM Tube, 1.23 x 0.370", 500 - 600 Operating Voltage

03/08/2017

PE 00230680

Procurement Evaluation for Terminal, Lug, PIDG Ring,

  1. 10 Stud, 10-10 AWG, Copper Body/Tin-Lead Plating

2/22/2019

PE 00239208

Procurement Evaluation: Disc Valves

09/22/2019

PE 00242473

Procurement Evaluation for Mortar, Masonry, Construction

Grade, Per ASTM C-270 Type M - Cat ID 43003-2

2/12/2019

PE 00264775

Procurement Evaluation: O-Ring

03/06/2023

PE 00277177

Procurement Evaluation for Lubricant, Oil, Mobil DTE

Extra Heavy, 55 Gal Barrel

01/10/2023

PE 00287176

Procurement Evaluation for Rebuild/Repair Kit,

Mechanical Seal, for Reactor Recirc Pump B Can-8 Seal

10/31/2023

PE 210371

Procurement Evaluation for Catalog Id: 5704, Circuit

Board for 125 Vdc Battery Charger

2/05/2017

PE 211658

Procurement Evaluation for Catalog Id: 10146, 480 V

Molded Case Circuit Breaker

01/18/2018

PE 23516

Procurement Evaluation for Catalog Id: 1066, 125 Vdc

HMA Relay

05/16/2003

PE 47981

Procurement Evaluation for Catalog Id: 1100595,

Electrolytic Capacitor

01/09/2006

PE 78447

Procurement Evaluation for Catalog Id: 27021, 120/24 V

11/20/2012

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

Control Power Transformer

PE CE-89-1361

Procurement Evaluation for Pressure Switch for

Emergency Diesel Generator Model 645

10/18/1989

PE M-94-0749-00

Procurement Evaluation for Pressure Switch (Detector

Assembly)

09/27/1994

PES-S-006

Code Reconciliation

SQ-CLD83

Dynamic Qualification of General Motors, Electromotive

Division (EMD) Crankcase Pressure Switches

06/10/1986

VC22-002

AMEREN-UE NUPIC JOINT UTILITIES SURVEY (VC22-

2) OF PARKER HANNIFIN CORPORATION

08/18/2022

076797

Certificate of Qualification for Receipt Inspector

09/16/2021

1374977

Purchase Order for Catalog Id: 5704, Circuit Board for 125

Vdc Battery Charger

06/09/2022

1378242

Purchase Order for Catalog Id: 1100595, Electrolytic

Capacitor

06/09/2022

2 (K2801-

0076-C)

Vendor Technical Information: Replacement Parts Catalog

Diesel Engines Model 645

981574

Certificate of Qualification for Receipt Inspector

08/19/2020

995475

Certificate of Qualification for Receipt Inspector

07/23/2024

ASME B16.22-

2001 Mandatory

Appendix II

Table II3 Dimensions of Solder-Joint Ends, in.

2/28/2004

Commercial

Grade Dedication

Requirements for

Cat ID 6447-2

PE Eval Q141 Panel for Cat ID 6447-2

CPS-29270

Exelon Power Labs Test Report on Catalog Id: 10146, 480

Vac Molded Case Circuit Breaker

11/12/2018

CPS-40358

CGD Testing of: Adapter, Tube, 5/8in. Nominal Solder

Joint x 3/4

05/29/2024

CPS-41244

CGD Testing of: Terminal, Lug, PIDG Ring, #10 Stud,

2-10 AWG, COP

05/31/2024

Miscellaneous

CPS-41308

CGD Testing of: Tube Assembly, Electrical, GM Tube,

1.23 x 0.370"

05/31/2024

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

CPS-41410

CGD Testing of: Bearing, Ball, Single Row Deep Groove,

110 MM

06/04/2024

CPS-87576

Exelon Power Labs Test Report on Catalog Id: 1066, 125

Vdc HMA Relay

08/16/2019

NO-AA-10

Standard Quality Assurance Topical Report

OSD&D 0070459

Housing, Filter, Model CT102, Brass Head/SS Sump, for

Refrigeration Unit

08/27/2013

OSD&D 0111267

Housing, Filter, Model CT102, SS Head/SS Sump, for

Refrigeration Unit

10/23/2019

PBI-2019-10-002

PBI Permit - Firewall - Potential Degradation of Fire

Barrier from South Side of Wall

2/19/2019

PO 00000703

Purchase Order Lower Bearing

PO 00000703

Purchase Order for Stem Assembly for Air Start Valve

Emergency Diesel Engine

08/19/2022

PO 00084680

Purchase Order Tubing Cap

07/02/2019

PO 00663360

Purchase Order for Housing Filter, Model CT102, SS

Head / SS Sump, for Refrigeration Unit - Cat ID 247670-2

10/15/2018

PO 00666452

Purchase Order: Rebuild/Repair Kit

PO 00679333

Purchase Order for Rebuild/Repair Kit, Mechanical Seal,

for Reactor Recirc Pump A, Can-8 Seal

06/26/2020

PO 00703686

Purchase Order: Disc Valves

PO 00709798

Purchase Order for Mortar, Masonry, Construction Grade,

Per ASTM C-270 Type Me - Cat ID 43003-2

11/22/2019

PO 00795368

Tube Assembly, Electrical, GM Tube, 1.23 x 0.370",

500-600 operating

08/21/2020

PO 00796899

Terminal, Lug, PIDG Ring, #10 Stud, 12-10 AWG, Copper

Body/Tin-Lead Plating

09/28/2020

PO 00803469

Bearing, Ball, Single Row Deep Grove, 110 MM

10/14/2020

PO 00805131

Purchase Order for Adapter, Tube, 5/8 in. Nominal Solder

Joint x 3/4 in. Male NPT, Copper, Solder - Cat ID 9703-2

2/20/2020

PO 00816482

Gauge, Pressure, 0-100 PSIG, 2-1/2 IN, 1/4 MNPT IN,

Bottom, Copper Alloy Bourdon Tube

03/15/2021

PO 01331232

Tee, Tubing, Union, 1/4" Tube x 1/4" Tube x 1/4" Tube,

Brass, ASTM B 283

08/18/2021

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

PO 01387494

Purchase Order: O-Rings

PO 01419036

Purchase Order for Emergency Diesel Crankcase

Pressure Switch

03/07/2024

PO 01454340

Rebuild/Repair Kit, Mechanical Seal, for Reactor Recirc

Pump B Can-8 Seal

03/29/2024

PO 462111

Purchase Order for Catalog Id: 10146, 480 Vac Molded

Case Circuit Breaker

2/20/2018

PO 522332

Purchase Order for Catalog Id: 1066, 125 Vdc HMA Relay

07/23/2019

PO 797100

Purchase Order for Catalog Id: 27021, 120/24 V Control

Power Transformer

10/22/2020

Receipt

Inspection

00196404

Receipt Inspection for Adapter, Tube, 5/8 in., Nominal

Solder Joint x 3/4 in. Male NPT, Copper - Cat ID 9703-2

11/04/2020

Receipt

Inspection

183375

Receipt Inspection Report for Catalog Id: 10146, 480 Vac

Molded Case Circuit Breaker

05/12/2018

Receipt

Inspection

185803

Housing Filter Model CT 102 SS Head/SS Pump F - Cat

ID 247670-2

10/31/2018

Receipt

Inspection

189627

Receipt Inspection Report for Catalog Id: 1066, 125 Vdc

HMA Relay

07/23/2019

Receipt

Inspection

2735

Mortar Masonry Construction Grade per ASTM C-270 -

Cat ID 43003-2

11/20/2019

Receipt

Inspection

196262

Receipt Inspection Report for Catalog Id: 27021, 120/24 V

Control Power Transformer

10/25/2020

Receipt

Inspection

203721

Assembly Stem for Air Start Valve for Emergency - Cat ID

29-1

05/04/2022

Receipt

Inspection

211456

Receipt Inspection Report for Catalog Id: 1100595,

Electrolytic Capacitor

01/27/2024

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

Receipt

Inspection

2542

Switch Pressure Detector Assembly Crankcase for Cat ID

34975-1

2/27/2024

Receipt

Inspection

213042

Receipt Inspection Report for Catalog Id: 5704, Circuit

Board for 125 Vdc Battery Charger

04/15/2024

SM-AA-102

Housekeeping Surveillance and Inspection

04/12/2024

SM-AA-102

Housekeeping Surveillance and Inspection

08/01/2023

SM-AA-102

Housekeeping Surveillance and Inspection

07/05/2023

SM-AA-102

Housekeeping Surveillance and Inspection

06/01/2023

SM-AA-102

Housekeeping Surveillance and Inspection

2/28/2024

SM-AA-102

Housekeeping Surveillance and Inspection

05/13/2024

SM-G-03

Receipt Inspector Training Program

Specification K-

2944

Amendment 32 to Specification K-2944 for Concrete and

Grout Work - Clinton Power Station - Units 1 and 2

07/10/1986

VTI 19EA-4ss

Vendor Technical Information for Start-Up, Operation and

Maintenance Instructions for Hermetic Centrifugal Liquid

Chillers

07/10/2001

207.02

Emergency Diesel Engine Maintenance

04/23/2013

CC-AA-320-1002

Dynamic (Seismic) Qualification for Alternate

Replacement Items and Commercial Grade Dedication

Items

MA-AA-716-001

Quality Material/Components Control and

Identification/Segregation of Non-Conforming Items

MA-AA-716-011

Work Execution and Close Out

Procedures

NEP-11-01

Procurement and Use of Items for Repair and

Replacement of Safety Related, Regulatory Related, and

Non-Safety Related Equipment

Inspection

Procedure

Type

Designation

Description or

Revision or

Date

NISP-EN-02

Standard Item Equivalency Process

NO-AA-501

Commercial Grade Surveys

PES-S-002

Shelf Life

PES-S-004

Sampling Plan

PI-AA-125

Corrective Action Program (CAP) Procedure

SM-AA-101

Certification of Receipt Inspectors

SM-AA-102

Warehouse Operations

SM-AA-104

In-Storage Maintenance

SM-AA-300

Procurement Engineering Support Activities

SM-AA-300-1001

Procurement Engineering Process and Responsibilities

SM-AA-3019

Parts Quality Initiative (PDI)

SM-AA-404

Nuclear Material Procurement

SM-AC-4005

Supplier Performance Measurement and Management

01632929-01

Replace High Crankcase Pressure Switch

09/19/2016

01632930-01

Replace High Crankcase Pressure Switch

09/19/2016

01665710-01

0VC13CB Replace Motor Cooler Filter Housing

03/13/2014

01726864-02

1DG01KC Replace Lower Liner Seals and Injectors-18

Year PM

10/31/2022

04931743

00158411-04, PMSR, 0VC13CB Change Oil/Oil Filters,

Refrigerant Strainer

2/07/2020

04974611-01

NOS ID Gap ID'd in Wall in Aux Electrical Equipment

Room

2/18/2019

Work Orders

05077714

0VC13Cb Very Small Freon Leak

2/03/2020