Emergency Preparedness Biennial Exercise Inspection Report 05000461/2023501
ML23334A202
Person / Time
Site: Clinton 
Issue date: 12/05/2023
From: Steven Orth
NRC/RGN-III/DRSS/SEPIR
To: Rhoades D
Constellation Energy Generation, Constellation Nuclear
References
IR 2023501
Download: ML23334A202 (1)


Text

SUBJECT:

CLINTON POWER STATION - EMERGENCY PREPAREDNESS BIENNIAL EXERCISE INSPECTION REPORT 05000461/2023501

Dear David Rhoades:

On November 16, 2023, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Clinton Power Station and discussed the results of this inspection with Norha Plumey, Site Vice President, and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Steven K. Orth, Chief Security, Emergency Preparedness, and Incident Response Branch Division of Radiological Safety and Security Docket No. 05000461 License No. NPF-62

Enclosure:

As stated

Inspection Report

Docket Number:

05000461

License Number:

NPF-62

Report Number:

05000461/2023501

Enterprise Identifier:

I-2023-501-0011

Licensee:

Constellation Nuclear

Facility:

Clinton Power Station

Location:

Clinton, IL

Inspection Dates:

November 13, 2023 to November 16, 2023

Inspectors:

G. Hansen, Sr. Emergency Preparedness Inspector

T. Iskierka-Boggs, Senior Operations Engineer

J. Kutlesa, Emergency Preparedness Inspector

T. Ospino, Resident Inspector

Approved By:

Steven K. Orth, Chief

Security, Emergency Preparedness, and Incident

Response Branch

Division of Radiological Safety and Security

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an emergency preparedness biennial exercise inspection at Clinton Power Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71114.01 - Exercise Evaluation

Inspection Review (IP Section 02.01-02.11) (1 Sample)

(1) The inspectors evaluated the biennial emergency plan exercise on November 14, 2023. The exercise scenario simulated an event at the Clinton Power Station that initiated with the declaration and notification of an Alert in response to AC power capability to vital busses being reduced to only one power source for equal to or greater than 15 minutes. The scenario conditions simulated the escalation of the significance of the event, requiring the declaration of a Site Area Emergency, and then a General Emergency, as well as the development of Protective Action Recommendations that were communicated to the required state and local government agencies.

71114.08 - Exercise Evaluation - Scenario Review

Inspection Review (IP Section 02.01 - 02.04) (1 Sample)

(1) The inspectors reviewed and evaluated the proposed scenario for the biennial emergency plan exercise on October 11,

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:

EP01: Drill/Exercise Performance (DEP) Sample (IP Section 02.12)===

(1) July 1, 2022 through June 30, 2023 EP02: Emergency Response Organization (ERO) Drill Participation (IP Section 02.13) (1 Sample)
(1) July 1, 2022 through June 30, 2023 EP03: Alert And Notification System (ANS) Reliability Sample (IP Section 02.14) (1 Sample)
(1) July 1, 2022 through June 30,

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On November 16, 2023, the inspectors presented the emergency preparedness biennial exercise inspection results to Norha Plumey, Site Vice President, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

AR 04461831

Clinton 2021 Biennial EP Exercise - SIM MCR - DC

Performance

11/18/2021

AR 04498184

NARS DEP Transmittal Exceeded 15 Min

05/06/2022

AR 04530625

EPID - Clinton EP 2022 Off-Year Exercise - TSC

Performance

10/11/2022

AR 04530630

EPID - Clinton EP 2022 Off-Year Exercise - OSC

Performance

10/11/2022

AR 04530632

EPID - Clinton EP 2022 Off-Year Exercise - EOF

Performance

10/11/2022

AR 04530637

EPID - Clinton EP 2022 Off-Year Exercise - SIM

Performance

10/11/2022

AR 04679810

EPID - 2023 EMPE Exercise TSC Performance

05/22/2023

AR 04679818

EPID - 2023 EMPE Exercise OSC Performance

05/22/2023

AR 04679984

EPID - 2023 EMPE Exercise Simulator (MCR) Performance

05/23/2023

AR 04680016

EPID Lessons Learned from 2023 EMPE Exercise

05/23/2023

AR 04695951

EPID - 2023 Clinton Pre-Exercise OSC Failed Objective K1

08/11/2023

AR 04695954

EPID - 2023 Clinton Pre-Exercise OSC Failed Objective K5

08/11/2023

AR 04695983

EPID - 2023 Clinton Pre-Exercise Sim Failed Objective F3

08/11/2023

AR 04695983

EPID - 2023 Clinton Pre-Exercise Sim Failed Objective F3

08/11/2023

AR 04695997

EPID - 2023 Pre-Exercise DC Learnings from Sim

08/11/2023

AR 04695999

EPID - 2023 Pre-Exercise DC Learnings from TSC

08/11/2023

Corrective Action

Documents

AR 04696000

EPID - 2023 Pre-Exercise DC Learnings from OSC

08/11/2023

EP-AA-1000

Exelon Nuclear Standardized Radiological Emergency Plan

EP-AA-1003

Exelon Nuclear Radiological Emergency Plan Annex for

Clinton Station

EP-AA-1003,

Addendum 3

Exelon Nuclear Emergency Action Levels for Clinton Station

EP-AA-110-200

Dose Assessment

EP-AA-111

Emergency Classification and Protective Action

Recommendations

71114.01

Procedures

EP-AA-112

Emergency Response Organization (ERO) / Emergency

Response Facility Activation and Operation

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

EP-AA-112-200

TSC Activation and Operation

EP-AA-112-400

Emergency Operations Facility Activation and Operation

EP-AA-113

Personnel Protective Actions

EP-AA-114

Notifications

EP-AA-114-F-02

BWR Release in Progress Determination Guidance

Rev A

EP-AA-114-F-12

Clinton Release in Progress Determination Guidance

Technical Basis Document

Rev A

71114.08

Miscellaneous

RS-23-092

Clinton Station 2023 Emergency Preparedness Biennial

Exercise Scenario

09/14/2023

AR 04461831

Clinton 2021 Biennial EP Exercise - SIM/MCR - DC

Performance

11/16/2021

AR 04497491

EP - Failed Siren Activation Command

05/03/2022

AR 04498184

NARS DEP Transmittal Exceeded 15 Minutes

04/15/2022

Corrective Action

Documents

AR 04498563

EP ID: Drill & Exercise Performance Indicator Revisions

05/06/2022

LS-AA-2110

Monthly Data Elements for NRC ROP Indicator - Emergency

Response Organization (ERO) Drill Participation

04/01/2022 -

06/30/2023

LS-AA-2120

Monthly Data Elements for NRC ROP Indicator -

Drill/Exercise Performance

04/01/2022 -

06/30/2023

Miscellaneous

LS-AA-2130

Monthly Data Elements for NRC ROP Indicator - Alert and

Notification System (ANS) Reliability

04/01/2022 -

06/30/2023

71151

Procedures

PI-AA-125

Corrective Action Program (CAP) Procedure

8