Emergency Preparedness Biennial Exercise Inspection Report 05000454/2025501 and 05000455/2025501
ML25351A058
Person / Time
Site: Byron  
Issue date: 12/18/2025
From: Michael Ziolkowski
NRC/RGN-III/DRSS
To: Mudrick C
Constellation Energy Generation, Constellation Nuclear
References
IR 2025501
Download: ML25351A058 (0)


Text

SUBJECT:

BYRON STATION - EMERGENCY PREPAREDNESS BIENNIAL EXERCISE INSPECTION REPORT 05000454/2025501 AND 05000455/2025501

Dear Christopher Mudrick:

On December 10, 2025, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Byron Station and discussed the results of this inspection with N. Burton and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Michael E. Ziolkowski, Chief Security, Emergency Preparedness, and Incident Response Branch Division of Radiological Safety and Security Docket Nos. 05000454 and 05000455 License Nos. NPF-37 and NPF-66

Enclosure:

As stated

Inspection Report

Docket Numbers:

05000454 and 05000455

License Numbers:

NPF-37 and NPF-66

Report Numbers:

05000454/2025501 and 05000455/2025501

Enterprise Identifier:

I-2025-501-0009

Licensee:

Constellation Energy Generation, LLC

Facility:

Byron Station

Location:

Byron, IL

Inspection Dates:

August 25, 2025, to December 10, 2025

Inspectors:

J. Kutlesa, Sr Emergency Preparedness Inspector

T. McGowan, Emergency Preparedness Inspector

Approved By:

Michael E. Ziolkowski, Chief

Security, Emergency Preparedness, and Incident Response Branch

Division of Radiological Safety and Security

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an emergency preparedness biennial exercise inspection at Byron Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors.

Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71114.01 - Exercise Evaluation

Inspection Review (IP Section 02.01-02.11) (1 Sample)

(1) The licensee performed a biennial emergency preparedness exercise in accordance with 10 CFR 50 Appendix E(IV)(F)(2)(b), (c), and (j)(iii)(2). This exercise occurred on October 21, 2025, during the 2025 Government Shutdown and, as a result, the inspectors had to review all available documentation to support the evaluation of this exercise per IP 71114.01 and have determined that the licensee has complied with all applicable regulations.

71114.08 - Exercise Evaluation - Scenario Review

Inspection Review (IP Section 02.01 - 02.04) (1 Sample)

(1) The inspectors reviewed and evaluated the proposed scenario for biennial emergency plan exercise on September 3, 2025.

OTHER ACTIVITIES - BASELINE

71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:

EP01: Drill/Exercise Performance (DEP) Sample (IP Section 02.12) (1 Sample)

(1) October 1, 2024, through September 30, 2025 EP02: Emergency Response Organization (ERO) Drill Participation (IP Section 02.13) (1 Sample)
(1) October 1, 2024, through September 30, 2025 EP04: Emergency Response Facility and Equipment Readiness (ERFER) (IP Section 02.14) (1 Sample)
(1) January 1 through September 30, 2025

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On December 10, 2025, the inspectors presented the emergency preparedness biennial exercise inspection results to N. Burton and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

AR 04908329

25 EP Byron NRC Graded Exercise: TSC DCs

10/23/2025

AR 04908331

25 EP Byron NRC Graded Exercise: OSC DCs

10/23/2025

AR 04908332

25 EP Byron NRC Graded Exercise: SIM CR DCs

10/23/2025

AR 04908495

25 EP Byron NRC Graded Exercise: EOF DCs

10/21/2025

Corrective Action

Documents

Resulting from

Inspection

AR 04908497

25 EP Byron NRC Graded Exercise: JIC DCs

10/24/2025

Byron Draft AAR

20 2025

FEMA Byron Generating Station Radiological Emergency

Preparedness Exercise Radiological Emergency

Preparedness Program Draft After-Action

Report/Improvement Plan Exercise Date: October 21, 2025

11/20/2025

Miscellaneous

EP-MW-114-100-

F-01

Nuclear Accident Reporting System (NARS) Forms for Alert,

Site Area Emergency, and General Emergency

10/21/2025

Procedures

EP-AA-1002

Radiological Emergency Plan Annex for Byron Station

71114.01

Self-Assessments N/A

Byron 2025 NRC Graded Exercise Evaluation Report

11/25/2025

EP-AA-1002

Addendum 3

Constellation Emergency Action Levels for Byron Station

71114.08

Miscellaneous

RS-25-128

Byron Station 2025 NRC Graded Exercise Manual

08/22/2025

LS-AA-2110

Monthly Data Elements for NRC ROP Indicator - Emergency

Response Organization (ERO) Drill Participation

10/01/2024

through

09/30/2025

LS-AA-2120

Monthly Data Elements for NRC ROP Indicator -

Drill/Exercise Performance

10/01/2024

through

09/30/2025

71151

Miscellaneous

LS-AA-2135

Monthly Data Elements for NRC ROP Indicator - Emergency

Response Facility and Equipment Readiness (ERFER)

01/01/2025

through

09/30/2025