September 12, 2014
SUBJECT:
MILLSTONE POWER STATION - NRC PROBLEM IDENTIFICATION AND RESOLUTION INSPECTION REPORT 05000336/2014009 AND 05000423/2014009
Dear Mr. Heacock:
On July 31, 2014, the United States Nuclear Regulatory Commission (NRC) completed an inspection at your Millstone Power Station, Units 2 and 3. The enclosed report documents the inspection results, which were discussed on July 31, 2014 with Mr. Stephen E. Scace, Site Vice President, and other members of your staff.
This inspection examined activities conducted under your license as they relate to identification and resolution of problems and compliance with the Commissions rules and regulations and conditions of your license. Within these areas, the inspection involved examination of selected procedures and representative records, observations of activities, and interviews with personnel.
No findings were identified.
Based on the samples selected for review, the inspectors concluded that Dominion was generally effective in identifying, evaluating, and resolving problems. Dominion personnel identified problems and entered them into the corrective action program at a low threshold.
Dominion prioritized and evaluated issues commensurate with the safety significance of the problems and corrective actions were generally implemented in a timely manner.
In accordance with Title 10 of the Code of Federal Regulations (CFR) 2.390 of the NRCs Rules of Practice, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of the NRCs document system (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Raymond R. McKinley, Chief Reactor Projects Branch 5 Division of Reactor Projects
Docket Nos. 50-336 and 50-423 License Nos. DPR-65 and NPF-49
Enclosure:
Inspection Report 05000336/2014009 and 05000423/2014009
w/Attachment: Supplementary Information
REGION I==
Docket Nos.
50-336 and 50-423
License Nos.
Report Nos.
05000336/2014009 and 05000423/2014009
Licensee:
Dominion Nuclear Connecticut, Inc.
Facility:
Millstone Power Station, Units 2 and 3
Location:
P.O. Box 128
Waterford, CT 06385
Dates:
July 14, 2014 through July 31, 2014
Team Leader:
S. Barber, Senior Project Engineer
Inspectors:
B. Haagensen, Resident Inspector A Bolger, Emergency Response Coordinator M. Fannon, Reactor Engineer
Approved by:
Raymond R. McKinley, Chief Reactor Projects Branch 5 Division of Reactor Projects
Enclosure
SUMMARY
IR 05000336/2014009, 05000423/2014009; 07/14/2014 - 07/31/2014; Millstone Power Station,
Units 2 and 3; Biennial Baseline Inspection of Problem Identification and Resolution.
This NRC team inspection was performed by three regional inspectors and one resident inspector. The NRCs program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, Reactor Oversight Process, Revision 5.
Problem Identification and Resolution
The inspectors concluded that Dominion was generally effective in identifying, evaluating, and resolving problems. Dominion personnel identified problems, entered them into the corrective action program at a low threshold, and prioritized issues commensurate with their safety significance. In most cases, Dominion appropriately screened issues for operability and reportability, and performed causal analyses that appropriately considered extent of condition, generic issues, and previous occurrences. The inspectors also determined that Dominion typically implemented corrective actions to address the problems identified in the corrective action program in a timely manner.
The inspectors concluded that, in general, Dominion adequately identified, reviewed, and applied relevant industry operating experience to Millstone Power Station, Units 2 and 3 operations. In addition, based on those items selected for review, the inspectors determined that Dominions self-assessments and audits were thorough.
Based on the interviews the inspectors conducted over the course of the inspection, observations of plant activities, and reviews of individual corrective action program and employee concerns program issues, the inspectors did not identify any indications that site personnel were unwilling to raise safety issues nor did they identify any conditions that could have had a negative impact on the sites safety conscious work environment.
No findings were identified.
REPORT DETAILS
OTHER ACTIVITIES (OA)
4OA2 Problem Identification and Resolution
This inspection constitutes one biennial sample of problem identification and resolution as defined by Inspection Procedure 71152. All documents reviewed during this inspection are listed in the Attachment to this report.
.1 Assessment of Corrective Action Program Effectiveness
a. Inspection Scope
The inspectors reviewed the procedures that described Dominions corrective action program (CAP) at Millstone Power Station, Units 2 and 3. To assess the effectiveness of the corrective action program, the inspectors reviewed performance in three primary areas: problem identification, prioritization and evaluation of issues, and corrective action implementation. The inspectors compared performance in these areas to the requirements and standards contained in 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, and Dominion procedure PI-AA-200, Corrective Action. For each of these areas, the inspectors considered risk insights from the stations risk analysis and reviewed condition reports selected across the seven cornerstones of safety in the NRCs Reactor Oversight Process. Additionally, the inspectors attended multiple Condition Review Team (CRT), Corrective Action Assignment Review Team (CAART)and Corrective Action Review Board (CARB) meetings. The inspectors selected items from the following functional areas for review: engineering, operations, maintenance, emergency preparedness, radiation protection, chemistry, physical security, and oversight programs.
- (1) Effectiveness of Problem Identification
In addition to the items described above, the inspectors reviewed system health reports, a sample of completed corrective and preventative maintenance work orders, completed surveillance test procedures, operator logs, and periodic trend reports. The inspectors also completed field walkdowns of various systems on site, such as the electrical distribution and safety injection systems. Additionally, the inspectors reviewed a sample of condition reports written to document issues identified through internal self-assessments, audits, emergency preparedness drills, and the operating experience program. The inspectors completed this review to verify that Dominion entered conditions adverse to quality into their corrective action program as appropriate.
- (2) Effectiveness of Prioritization and Evaluation of Issues
The inspectors reviewed the evaluation and prioritization of a sample of condition reports issued since the last NRC Biennial Problem Identification and Resolution inspection completed in June 2012. The inspectors also reviewed condition reports that were assigned lower levels of significance that did not include formal cause evaluations to ensure that they were properly classified. The inspectors review included the appropriateness of the assigned significance, the scope and depth of the causal analysis, and the timeliness of resolution. The inspectors assessed whether the evaluations identified likely causes for the issues and developed appropriate corrective actions to address the identified causes. Further, the inspectors reviewed equipment operability determinations, reportability assessments, and extent-of-condition reviews for selected problems to verify these processes adequately addressed equipment operability, reporting of issues to the NRC, and the extent of the issues.
- (3) Effectiveness of Corrective Actions
The inspectors reviewed Dominions completed corrective actions through documentation review and, in some cases, field walkdowns to determine whether the actions addressed the identified causes of the problems. The inspectors also reviewed condition reports for adverse trends and repetitive problems to determine whether corrective actions were effective in addressing the broader issues. The inspectors reviewed Dominions timeliness in implementing corrective actions and effectiveness in precluding recurrence for significant conditions adverse to quality. The inspectors also reviewed a sample of condition reports associated with selected non-cited violations and findings to verify that Dominion personnel properly evaluated and resolved these issues.
In addition, the inspectors expanded the corrective action review to five years to evaluate Dominion actions related the Unit 2 Emergency Diesel Generators (EDGs).
b.
Assessment
- (1) Effectiveness of Problem Identification
Based on the selected samples, plant walkdowns, and interviews of site personnel in multiple functional areas, the inspectors determined that Dominion identified problems and entered them into the corrective action program at a low threshold. Dominion staff at Millstone Power Station, Units 2 and 3 initiated approximately 28,000 condition reports between June 2012 and June 2014. The inspectors observed supervisors at the CRT, CAART and CARB meetings appropriately questioning and challenging condition reports to ensure clarification of the issues. Based on the samples reviewed, the inspectors determined that Dominion trended equipment and programmatic issues, and appropriately identified problems in condition reports. The inspectors verified that conditions adverse to quality identified through this review were entered into the corrective action program as appropriate. Additionally, inspectors concluded that personnel were identifying trends at low levels. In general, inspectors did not identify any issues or concerns that had not been appropriately entered into the corrective action program for evaluation and resolution. In response to several questions and minor equipment observations identified by the inspectors during plant walkdowns, Dominion personnel promptly initiated condition reports and/or took immediate action to address the issues.
- (2) Effectiveness of Prioritization and Evaluation of Issues
The inspectors determined that, in general, Dominion appropriately prioritized and evaluated issues commensurate with the safety significance of the identified problem.
Dominion screened condition reports for operability and reportability, categorized the condition reports by significance, and assigned actions to the appropriate department for evaluation and resolution. The condition report screening process considered human performance issues, radiological safety concerns, repetitiveness, adverse trends, and potential impact on the safety conscious work environment.
Based on the sample of condition reports reviewed, the inspectors noted that the guidance provided by Dominion corrective action program implementing procedures appeared sufficient to ensure consistency in the categorization of issues. Operability and reportability determinations were generally performed when conditions warranted and in most cases, the evaluations supported the conclusion. Causal analyses appropriately considered the extent of condition or problem, generic issues, and previous occurrences of the issue. However, the inspectors did observe some weaknesses in Dominions prioritization and evaluation of the following issues:
Missed Common Cause Evaluation for the Unit 2 B Emergency Diesel Generator
During a planned five year review of a selected safety-related system, the inspectors identified a potential technical specification (TS) noncompliance with the Unit 2 B EDG.
Specifically, CR354040 documented the need to do a common cause failure evaluation within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per TS 3.8.1.1. Action b.2 for a failed time delay relay and one was not performed in a timely manner.
On August 19, 2009, the TC065 time delay relay for the B EDG was declared inoperable because it would not change state during a routine calibration. On September 1, 2009, the TC057 time delay relay for the A EDG was declared inoperable because it also would not change state. Each of these time delay relays, also designated as the TD6 relay, blocks nonessential EDG trips just prior to and shortly after an emergency start. Both of these defective relays were replaced prior to restoring the affected EDG to an operable status from their preplanned system outage windows. In CR354040, the system engineer indicated that these relays may have a safety function and the failure of the TC065 relay may have caused a historical inoperability of the B EDG. This condition should have required a common cause failure evaluation per TS 3.8.1.1. Action b.2. The inspectors reviewed the operator logs to determine if an evaluation had been completed. On August 20, 2009, at 10:06 a.m., the control logs did evaluate the functions of the TD1, TD2, and TD3 time delay relay for the B EDG and adequately described why these degraded relays did not impact the EDGs ability to start and load. However, there was no discussion or evaluation of the TD6 relay. When questioned by the inspectors, Operations was unable to produce any other records from that time period that showed that the common cause evaluation was performed within 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per TS 3.8.1.1. Action b.2.
The inspectors reviewed engineering evaluation 25203-ER-09-0036 dated October 27, 2009, which documented Dominions historical operability review of the TC057 and TC065 time delay relay failures. In this evaluation, Dominion identified that a different relay, the ESS relay, also blocks nonessential EDG trips during and following a valid emergency start per the original plant design. This evaluation also stated that the functions of the TC057 and TC065 time delay relays were added by a 1976 plant design change to ensure that any pre-existing nonessential EDG trips would not impact EDG emergency start capability. Their function was noted as redundant and was not essential in assuring EDG operability. The inspectors reviewed this evaluation and had no basis to disagree with this conclusion. However, the inspectors noted that this evaluation took more than two months to complete from the date of the original relay failure. Thus, the EDG could have been susceptible to a common cause failure during this time frame because this condition was not evaluated in a timely manner.
The inspectors independently evaluated the deficiencies noted above for significance in accordance with the guidance in IMC 0612, Appendix B, Issue Screening, and Appendix E, Examples of Minor Issues. The inspectors noted that: 1) engineering evaluation 25203-ER-09-0036 concluded that safety-related function of blocking of nonessential trips was performed by a different relay, the ESS relay, which made the function of the TD6 relays redundant, and 2) the need to do the TS related common cause failure evaluation became moot once the relays were determined to be non-essential with respect to EDG operability. Thus, the inspectors determined that this deficiency was of minor significance and, therefore, was not subject to enforcement action in accordance with the NRCs Enforcement Policy. Dominion documented this issue in CR555383.
10 CFR 21 Reportability for Degraded Unit 2 Reactor Protection System Relays
On April 20, 2014, Dominion determined that nine of 22 Unit 2 reactor protection system (RPS) matrix relays received from Westinghouse failed bench testing. These relays were being procured to replace the original equipment relays no longer available from Combustion Engineering. Dominion had originally requested 30 relays but only received 22 relays after eight of them failed factory testing. As documented in CR545784, CR548749, and CA281788, Dominion initiated a corrective action to notify the vendor, Westinghouse, of the need to evaluate these failures in accordance with 10 CFR 21.
The relays were subsequently shipped to Westinghouse on April 25, 2014 for further evaluation and the vendor was also notified of the need for a Part 21 evaluation. When Dominion followed up with Westinghouse on May 28, 2014 to check on the status of their evaluation, Westinghouse informed them that the relays were sent to a sub-vendor for further evaluation. Dominion attempted to contact Westinghouse again on June 28, 2014 but did not receive any response. During this inspection, on July 31, 2014, the inspectors questioned Dominion on whether an interim report should have been submitted within 60 days of discovery of a defect in accordance with 10 CFR 21.21 (a)(2). The inspectors also questioned Dominion regarding why there was no additional follow up after the June 28, 2014 attempt. Later that same day, Dominion was able to retrieve a Westinghouse supplied evaluation of the relays that had been previously completed on June 14, 2014. This evaluation determined that the failures did not constitute a substantial safety hazard and, therefore, were not to be reportable under 10 CFR 21. The inspectors reviewed the evaluation and had no basis to disagree with the vendors conclusion. The inspectors noted that this evaluation was not conveyed to Dominion until contact was made at the inspectors behest on July 31, 2014.
The inspectors independently evaluated the deficiencies noted above for significance in accordance with the guidance in IMC 0612, Appendix B, Issue Screening, and Appendix E, Examples of Minor Issues. The inspectors noted that: 1) none of the new style RPS matrix relays were ever installed in the plant, 2) Dominion never took possession of the 22 RPS matrix relays because all of them were returned to the vendor after nine of them failed pre-installation testing in the warehouse, and 3) although Dominion was unaware of the evaluation, the vendor had completed the evaluation within the 60 days prescribed in 10 CFR 21.21 (a)(2). Thus, the inspectors determined this issue was a deficiency of minor significance, and therefore, was not subject to enforcement action in accordance with the NRCs Enforcement Policy. Dominion documented this issue in CR555384.
Multiple Unit 3 A Control Building Chiller Delayed Starts
The inspectors identified that Dominion failed to initially categorize numerous condition reports, generated for the delayed start of the Unit 3 A Control Building Chiller, as potential repeat events as described in procedure PI-AA-200, Corrective Action.
Since September 2013, there have been multiple instances where the A Chiller did not start as expected when the B Chiller was placed in a standby condition. The A Chiller typically failed to start on the first attempt when the B chiller was placed in standby (the normal method for shifting chillers) but would consistently start after a 15 minute timer recycled and repeated the start sequence. After the initial CR (CR525109), three additional CRs (CR526349, CR534558, and CR540488) were generated to document the deficiency with the A Chiller start logic. Each CR described that the deficiency had occurred previously and cited the basis for operability verbatim from the original CR.
PI-AA-200 defines a potential repeat as An identified condition (failure, problem or deficiency) that has had a previous occurrence documented within the Corrective Action Program. When determining if a Significance Level 3 event is a Potential Repeat, review events for the previous three years. Contrary to the above, none of those CRs were flagged as a potential repeat issue and they were either closed to a work order (WO) or closed to trend in the case of CR534558.
On March 27, 2014, CR543558 documented another instance of the A Chiller failing to start on the initial start sequence. The CR described the deficiency as a repeat issue and was flagged as a potential repeat event. PI-AA-200, Attachment 5, Condition Report Screening Matrix states, If an event is determined to be a potential repeatwith no previous cause evaluation, then CRT should consider assigning a cause evaluation of a level appropriate to the significance of the failure. CR543558 was closed to another WO and no additional corrective actions were taken which was contrary to this guidance. On June 17, 2014, CR551853 documented the A Chiller again failing to start on the initial start sequence. CR551835 documented another instance of this recurring problem and also noted that past WOs have not resolved the issue. A corrective action was assigned to design engineering to complete a design change to include a replace-ment of the relay circuit board that contains the chillers start logic. The inspectors discussed this issue with design engineering and noted that they were scheduled to begin modification activity in September 2014. They have a circuit board on site which needs only minimal modification before replacing the existing circuit board. Based on Dominions activities to date, it appears likely that this potential repeat issue will be corrected before the end of the year.
The inspectors independently evaluated the deficiencies noted above for significance in accordance with the guidance in IMC 0612, Appendix B, Issue Screening, and Appendix E, Examples of Minor Issues. The inspectors noted that 1) the safety related start function is actuated from a different portion of the relay circuit board for the chillers start logic that remained unaffected by the normal start function problems, 2)although Dominion acknowledged that it was undesirable to rely on a backup start function, there were no instances identified in which the 15 minute recycle timer failed to start the Unit 3 A Control Building Chiller after the normal start switch did not work properly, and 3) the purpose of a potential repeat event per PI-AA-200 is to allow CRT to determine if the significance of an underlying issue should be elevated to ensure timely corrective action which was done in the corrective action for CR551853 in this case because it implemented a design change to replace the relay circuit board for the chillers start logic. The inspectors determined through discussions with the system and design engineering that the design change was underway and should be installed by September 2014. Thus, the inspectors determined this issue was a deficiency of minor significance, and therefore, was not subject to enforcement action in accordance with the NRCs Enforcement Policy. Dominion documented this issue in CR555384.
- (3) Effectiveness of Corrective Actions
The inspectors concluded that corrective actions for identified deficiencies were generally timely and adequately implemented. For significant conditions adverse to quality, Dominion identified actions to prevent recurrence. The inspectors concluded that corrective actions to address the sample of NRC non-cited violations and findings since the last problem identification and resolution inspection were timely and effective.
The inspectors did observe some weaknesses in Dominions resolution of degraded conditions.
Circuit Breaker Testing
The inspectors identified circumstances in which Dominion did not consistently implement timely corrective actions to fully address conditions that had been identified in condition reports related to circuit breaker testing. Specifically, the inspectors reviewed the implementation of corrective actions for two breaker testing issues.
In June 2012, CR479475 documented that a replacement breaker for the starter on control room supply fan (3HCV*FN1B) had failed to start the fan when required due to an improper configuration in a newly installed breaker. The inspectors reviewed this CR and determined that Dominion did not adequately specify post maintenance testing (PMT) requirements for this circuit breaker installation. This noncompliance was documented as an NCV in 05000423/2012002-01, Inadequate Post Maintenance Testing of Breakers and CR493172 was initiated to for this NCV. Dominion concluded in Apparent Cause Evaluation (ACE) 019309 that reviewed this condition report there may have been a lack of specificity in the procedure for the post maintenance testing of breakers as described in MP-20-WP-GDL40, Pre and Post Maintenance Testing Guideline that contributed to this event. Subsequently, CA285045 assigned a formal self-assessment to design engineering to update this procedure to ensure system operability and functional capabilities were adequately evaluated during PMT activities.
The due date for this corrective action was extended to October 2015 and no significant changes have been made to the GDL40 breaker testing procedure which is over three years since the original test failure occurred.
In June 2014, Dominion Maintenance identified in CR551831 that Engineering did not adequately specify the PMT requirements for breaker replacements in PT 21424B, MP2 Type AK Breakers with EC Trip Devices Test. CR551831 stated that the test criteria in the procedure were difficult to interpret in the field by maintenance technicians because they had to determine breaker trip settings by interpolation of breaker curves. Dominion acknowledged that the interpolation was difficult, but could be done. However, they issued CA285045 to lessen the likelihood of errors while interpreting these breaker curves. However, this corrective action was subsequently closed to a procedure change request (PCR) which is a process outside of the CAP. The PCR could not be tracked to completion. To date, this procedure change has not been implemented.
For the two issues discussed above, the inspectors independently evaluated the deficiencies noted above for significance in accordance with the guidance in IMC 0612, Appendix B, Issue Screening, and Appendix E, Examples of Minor Issues. The inspectors noted that: 1) the NRC documented an NCV for the first issue in 05000423/2012002-01, Inadequate Post Maintenance Testing of Breakers, 2) for this issue, although Dominion acknowledged that the guidance in GDL40 breaker testing procedure could be enhanced, they attributed the actual cause of the NCV to poor work planning, and plan to update the procedure based on its safety significance, and 3)
Dominion also considers changes to PT 21424B, MP2 Type AK Breakers with EC Trip Devices Test, to also be enhancements that will be implemented based on their safety significance. The inspectors noted that although Dominion is following its existing CAP processes and procedures for implementing these procedure changes, the likelihood of errors is increased until these changes are fully implemented. The inspectors determined that the two issues described above constituted deficiencies of minor significance and, therefore, were not subject to enforcement action in accordance with the NRCs Enforcement Policy. Dominion created a procedure change request which is due to be completed by October 28, 2014.
.2 Assessment of the Use of Operating Experience
a. Inspection Scope
The inspectors reviewed a sample of condition reports associated with review of industry operating experience to determine whether Dominion appropriately evaluated the operating experience information for applicability to Millstone Power Station, Units 2 and 3 and had taken appropriate actions, when warranted. The inspectors also reviewed evaluations of operating experience documents associated with a sample of NRC generic communications to ensure that Dominion adequately considered the underlying problems associated with the issues for resolution via their corrective action program.
In addition, the inspectors observed various plant activities to determine if the station considered industry operating experience during the performance of routine and infrequently performed activities.
b.
Assessment
The inspectors determined that Dominion appropriately considered industry operating experience information for applicability, and used the information for corrective and preventive actions to identify and prevent similar issues when appropriate. The inspectors determined that operating experience was appropriately applied and lessons learned were communicated and incorporated into plant operations and procedures when applicable. The inspectors also observed that industry operating experience was routinely discussed and considered during the conduct of CRT meetings and pre-job briefs.
c. Findings
No findings were identified.
.3 Assessment of Self-Assessments and Audits
a. Inspection Scope
The inspectors reviewed a sample of audits, including the most recent audit of the corrective action program, departmental self-assessments, and assessments performed by independent organizations. Inspectors performed these reviews to determine if Dominion entered problems identified through these assessments into the corrective action program, when appropriate, and whether Dominion initiated corrective actions to address identified deficiencies. The inspectors evaluated the effectiveness of the audits and assessments by comparing audit and assessment results against self-revealing and NRC-identified observations made during the inspection.
b.
Assessment
The inspectors concluded that self-assessments, audits, and other internal Dominion assessments were generally critical, thorough, and effective in identifying issues. The inspectors observed that Dominion personnel knowledgeable in the subject completed these audits and self-assessments in a methodical manner. Dominion completed these audits and self-assessments to a sufficient depth to identify issues which were then entered into the corrective action program for evaluation. In general, the station implemented corrective actions associated with the identified issues commensurate with their safety significance.
c. Findings
No findings were identified.
.4 Assessment of Safety Conscious Work Environment
a. Inspection Scope
During interviews with station personnel, the inspectors assessed the safety conscious work environment at Millstone Power Station, Units 2 and 3. Specifically, the inspectors interviewed personnel to determine whether they were hesitant to raise safety concerns to their management and/or the NRC. The inspectors also interviewed the station Employee Concerns Program coordinator to determine what actions are implemented to ensure employees were aware of the program and its availability with regards to raising safety concerns. The inspectors reviewed the Employee Concerns Program files to ensure that Dominion entered issues into the corrective action program when appropriate.
b.
Assessment
During interviews, Millstone Power Station, Units 2 and 3 staff expressed a willingness to use the corrective action program to identify plant issues and deficiencies and stated that they were willing to raise safety issues. The inspectors noted that no one interviewed stated that they personally experienced or were aware of a situation in which an individual had been retaliated against for raising a safety issue. All persons interviewed demonstrated an adequate knowledge of the corrective action program and the Employee Concerns Program. Based on these limited interviews, the inspectors concluded that there was no evidence of an unacceptable safety conscious work environment and no significant challenges to the free flow of information.
c. Findings
No findings were identified.
4OA6 Meetings, Including Exit
On July 31, 2014, the inspectors presented the inspection results to with Stephen Scace, Site Vice President, and other members of the Millstone Power Station, Units 2 and 3 staff. The inspectors verified that no proprietary information was retained by the inspectors or documented in this report.
ATTACHMENT:
SUPPLEMENTARY INFORMATION
SUPPLEMENTARY INFORMATION
KEY POINTS OF CONTACT
Licensee Personnel
- C. Acuna, Unit 2 Shift Manager
- A. Bassham, Organizational Effectiveness Manager
- H. Beeman, Engineering Supervisor
- T. Berger, Unit 3 Shift Manager
- D. Delcore, Health Physics Shift Supervisor
- K. Deveau, Engineering Specialist, Engineering Coordination
- T. Fecteau, Electrical Engineer, I&C
- G. Gardner, Consulting Engineer
- D. Guarneri, Nuclear Technical Specialist III
- S. Hanerfeld, Supervisor Corrective Action Program, Organizational Effectiveness
- T. Horner, Supervisor Nuclear Station Procedures
- G. Johnson, Employee Concerns Program Coordinator
- D. Lowell, Reactor Protection System Engineer
- P. Ludington, Unit 3 Control Operator
- C. Maxson, Manager Nuclear Engineering
- G. McGovern, Nuclear Maintenance Supervisor
- R. McGuinness, Nuclear Engineer III
- J. Rigatti, Nuclear Site Engineering Manager
- D. Rowe, Unit 3 Shift Manager
- P. Russell, Unit 3 Shift Manager
- M. Sanders, Emergency Preparedness Specialist
- L. Salyards, Licensing Specialist
- P. Sikorski, Unit 3 Shift Manager
- D. Smith, Manager Emergency Preparedness
- S. Smith, Nuclear Operations Manager
- A. Vomastek, Fleet Employee Concerns Program Manager
Audits and Self-Assessments
Control of Chemicals (SAR002498)
Emergency Preparedness Audit (14-02)
Formal Self-Assessment of Procedure Use and Verification Practices (SAR002223)
Insufficient Work Instruction (Work Order Quality) (SAR002541)
ISI, IST, and Appendix J Audit (13-07)
Maintenance Audit (12-11)
MPS Operation Crews Effectively Using Trending Tools (SAR000402)
MPS Operation Crews Effectively Using Trending Tools (SAR002765)
NRC Pre-Baseline Self-Assessment of Emergency Preparedness (SAR002468)
Radioactive Material Control (SAR002275)
Radiological Protection/Process Control Program/ Chemistry Audit (12-06)
Security Training and HU DLA Reinforcement (SAR002765)
Self-Assessment of the Dominion Environmental Qualification Programs at North Anna, Surry,
and Millstone (SAR002395),
Validation of Progress and Sustainability of the OPs Section of the MEP (SAR002874)
Condition Reports (* indicates that condition report was generated as a result of this inspection)
CR349782
CR354906
CR364480
CR369274
CR372504
CR373278
CR374466
CR380975
CR381029
CR386544
CR438054
CR438193
CR461316
CR465654
CR474513
CR476942
CR485044
CR485651
CR486562
CR490245
CR490681
CR495762
CR496190
CR498542
CR508143
CR508785
CR511559
CR511560
CR511856
CR512007
CR512896
CR512905
CR515154
CR516428
CR516432
CR516508
CR516764
CR516799
CR517451
CR518604
CR520476
CR520672
CR520808
CR521911
CR523046
CR523289
CR523582
CR525109
CR526349
CR527739
CR529097
CR531109
CR532453
CR533986
CR534421
CR534558
CR534734
CR536674
CR537067
CR537106
CR537117
CR538720
CR538925
CR539413
CR539463
CR539596
CR540188
CR540274
CR540407
CR540448
CR540693
CR540795
CR541080
CR541415
CR541456
CR541507
CR541601
CR541982
CR541992
CR542278
CR542396
CR543256
CR544149
CR545183
CR545784
CR545893
CR547086
CR547411
CR547691
CR548482
CR548631
CR548658
CR548749
CR548912
CR549517
CR549614
CR549905
CR550765
CR550789
CR551544
CR551831
CR551853
CR552097
CR552213
CR552475
CR552477
CR552843
CR552863
CR552956
CR553102
CR553401
CR555213*
CR555029
CR555383*
CR555384*
Drawings
203-11013 SKS-AGR-PADISCH
275.200-041, Turbine Driven Auxiliary Feedwater Pump, Revision 63
Operating Experience
CR520627, Crane Nuclear Part 21 Notification for Unit 3 Service Water Valves
IN 2013-01, Emergency Action Level Thresholds Outside the Range of Radiation Monitors
Part 21 2012-47-00, Fairbanks Morse Opposed Piston EDG Oil Pump Leak, 9/28/2012
Part 21 2012-48-00, Fairbanks Morse Opposed Piston EDG Oil Pump Leak
Part 21 2013-60-00, Deficiency Related to the Primary Close Latch in K-Line Circuit Breakers,
11/25/2013
Part 21 2014-06-00, Interim Report Regarding TRICENTRIC Triple Offset Butterfly Valves,
2/07/2014
OE35296, D23 EDG Inoperable due to Blown Fuse in Voltage Regulator Motor Operated
Controller (MOC-2) Assembly, 1/15/2012
OE35837, Inadequate Design Change Implementation Processes Result in Appendix R
Shutdown Instructions and Related Training Deficiencies (Browns Ferry Station)
OEE001682, Non-conservative Operator Manual Actions Identified in Appendix R Analysis
Non-Cited Violations and Findings05000336/2012004-02, Corrective Action to Prevent Recurrence Ineffective to Preclude
Repetition of a Significant Condition Adverse to Quality
05000336/2013002-01, Inadequate Post Maintenance Testing Following PORV Maintenance
05000336/423/2014403-01, Failure to Monitor UAO
05000423/2012002-01, Inadequate Post Maintenance Testing of Breakers05000423/2012503-01, Failure to Adequately Implement Fuel Clad Barrier EALs05000423/2013003-01, Failure to Implement Annunciator Response Procedure for a Loss of
Ventilation during a Battery Charge
05000423/2013003-03, Failure to Make a 10 CFR 50.72(b)(3)(v)Report for a Major Loss of
Emergency Assessment Capability for the Stack Radiation Monitor
05000423/2013004-01, Inadequate Corrective Actions to Restore Degraded Unit 3 Main
Feedwater Isolation Valves
Procedures
C EN 104I, Condition Monitoring of Structures, Revision 007-01
C SP 750, Battery Weekly and Quarterly Surveillance, Revision 002-03
C SP 750-002, Unit 2 Battery Quarterly Inspection, Revision 001-05
CP 2802N, Primary Systems Sampling and Analysis, Revision 001-06
CM-AA-REA-1001, Request for Engineering Assistance, Revision 3
CM-AA-400, 10 CFR 50.59 and 72.48 Changes Tests and Experiments, Revision 3
D-NOCP-2012, Internal Audit Program, Revision 9
DNAP-1801, Internal Auditing and Oversight, Revision 5
EC-AA-110, Identifying and Addressing Nuclear Safety and Quality Concerns, Revision 0
ECP-GL-1, Nuclear Employee Concerns Program, Revision 11
MA-AA-102, Foreign Material Exclusion, Revision 15
MP-26-EPI-FAP07, Notifications and Communications, Revision 019
MP-26-EPA-FAP01, Management Program for Maintaining Emergency Preparedness, Rev 012
OP-AA-102, Operability Determination, Revision 11
OPS-OP 2346A, A Emergency Diesel Generator, Revision 028-5
PT 21424B, MP2 Type AK Breakers with EC Trip Devices Test, Revision 002-08
PI-AA-100-1004, Self-Assessments, Revision 11
PI-AA-100-1007, Operating Experience Program, Revision 11
PI-AA-200, Corrective Action, Revision 22
PI-AA-200-2001, Trending, Revision 5
PI-AA-200-2002, Effectiveness Reviews, Revision 6
PI-AA-300, Cause Evaluation, Revision 7
PI-AA-300-3000, Emergent Issue Response, Revision 4
PI-AA-300-3001, Root Cause Evaluation, Revision 4
PI-AA-300-3002, Apparent Cause Evaluation, Revision 6
PI-AA-300-3003, Common Cause Evaluation, Revision 0
PI-AA-300-3004, Cause Evaluation Methods, Revision 3
RAC 14, Non-Emergency Station Events, Revision 003-09
SP 3673.6, Accident Monitoring Instrumentation, Revision 04-07
SP 3673.6-001, Accident Monitoring Instrumentation, Revision 009-08
WM-AA-100, Work Management, Revision 24
WM-AA-101, Work Order Planning, Revision 2
Work Orders
WO53102560836
WO53102609673
WO53102637083
WO53102664998
WO53102749993
Miscellaneous
50.59 Screen OD000577, SO 14-004
Basler Electric Instruction Manual for Exciter Diode Monitor for Brushless Exciters, Model
EDM 200
DCN MP3-14-01107, MP3 TDAFW Pump Overspeed Margin Change, Revision 0
DCN MP3-10-01116, Station Blackout Diesel Generator Annunciator Modification, Revision 0
Design Change MP3-14-01101, 3HVK*CHL1A Relay Module Replacement, Revision 000
Email from
Equipment/System Reliability Summary dated January 7, 2014NEI 96-07, Revision 1,
Guidelines for 10 CFR 50.59 Implementation, November 2000
Memorandum from Clark Maxson to CAART, Subj: Request ACE 19696 SBO Computer
Failure - Emergency Shutdown be downgraded, Dated March 27, 2014
Millstone Power Station Unit 2 Outage Report 2R20
Millstone Power Station Unit 2 Outage Report 2R21
Millstone Power Station Unit 3 Outage Report 3R14
Millstone Power Station Unit 3 Outage Report 3R15
MRE016638, Frequent SBO Computer Trouble Alarms in and clear, Dated July 30, 2013
MRE017309, SBO Computer Failure - Emergency Shutdown, March 11, 2013
MRE017036, Emergency Stop of SBO Diesel
MP-REA-639 LOE #39, SBO Diesel Annunciator Exciter Diode Failure
Nuclear Oversight - 2R22 Snapshot, May 2, 2014
RMS073C, Radiation Monitoring System, Revision 3 Change 3
Millstone Power Station Employee Concerns Record from 2012 through 2014 (various)
LIST OF ACRONYMS
Apparent Cause Evaluation
Agency-wide Documents Access and Management System
CA
Corrective Action
CAART
Corrective Action Assignment Review Team
Corrective Action Program
CFR
Code of Federal Regulations
CR
Condition Report
Condition Report Review Team
IMC
Inspection Manual Chapter
NRC
Nuclear Regulatory Commission
Publicly Available Records System
Root Cause Evaluation