September 1, 2015

SUBJECT:

MID-CYCLE ASSESSMENT LETTER FOR EDWIN I. HATCH NUCLEAR PLANT

UNIT 1 AND UNIT 2 (NRC INSPECTION REPORT 05000321/2015005 AND

05000366/2015005)

Dear Mr. Vineyard:

On August 11, 2015, the NRC completed its mid-cycle performance review of Edwin I. Hatch Nuclear Plant, Unit 1 and Unit 2. The NRC reviewed the most recent quarterly performance indicators (PIs) in addition to inspection results and enforcement actions from July 1, 2014, through June 30, 2015. This letter informs you of the NRCs assessment of your facility during this period and its plans for future inspections at your facility.

The NRC determined that overall, Edwin I. Hatch Nuclear Plant, Unit 1 and Unit 2 operated in a manner that preserved public health and safety and met all cornerstone objectives. The NRC determined the performance at Edwin I. Hatch Nuclear Plant, Unit 1 and Unit 2 during the most recent quarter was within the Licensee Response Column of the NRCs Reactor Oversight Process (ROP) Action Matrix because all inspection findings had very low (i.e., Green) safety significance, and all PIs indicated that your performance was within the nominal, expected range (i.e., Green). Therefore, the NRC plans to conduct ROP baseline inspections at your facility.

The enclosed activity plan lists the inspections scheduled through June 30, 2017. Routine inspections performed by resident inspectors are not included in the inspection plan. In addition to baseline inspections, the NRC plans to conduct reactor operator license examinations and post-approval license renewal inspections. The inspections listed during the second half of the inspection plan are tentative and may be revised at the end-of-cycle performance review. The NRC provides the inspection plan to allow for the resolution of any scheduling conflicts and personnel availability issues. The NRC will contact you as soon as possible to discuss changes to the inspection plan should circumstances warrant any changes. This inspection plan does not include security related inspections, which will be sent via separate, non-publicly available correspondence. In response to the accident at Fukushima, the NRC is conducting audits of licensee efforts towards compliance with Commission issued Orders EA-12-049, Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events, and EA-12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation. As stated in our End-of-Cycle Performance Assessment letter on March 4, 2015, this audit includes an onsite component in order for the NRC to evaluate licensee plans for complying with these Orders and to receive and review information associated with open items.

The date for the onsite component at your site is being coordinated with your staff. A site-specific audit plan for the visit will be provided in advance to allow sufficient time for preparations.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Please contact me at 404-997-4513 with any questions you have regarding this letter.

Sincerely,

/RA/

Shane Sandal, Chief Reactor Projects Branch 2 Division of Reactor Projects

Docket Nos.: 50-321, 50-366 License Nos.: DPR-57, NPF-5

Enclosure: Hatch Inspection/Activity Plan

(09/01/2015 - 06/30/2017)

cc: distribution via ListServ

_________________________

SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE RII:DRP RII:DRP RII:DRP

SIGNATURE ELP1 CWR1 SRS5

NAME E. Powell C. Rapp S. Sandal

DATE 8/17/2015 8/18/2015 8/21/2015 9/ /2015 9/ /2015 9/ /2015 9/ /2015 E-MAIL COPY?

YES NO YES NO YES NO YES NO YES NO YES NO YES NO Letter to David Vineyard from Shane Sandal dated September 1, 2015

SUBJECT:

MID-CYCLE ASSESSMENT LETTER FOR EDWIN I. HATCH NUCLEAR PLANT

UNIT 1 AND UNIT 2 (NRC INSPECTION REPORT 05000321/2015005 AND

05000366/2015005)

DISTRIBUTION:

D. Gamberoni, RII L. Gibson, RII OE Mail RIDSNRRDIRS PUBLIC A. Adams, NRR RidsNrrPMHatch Resource ROP Assessment ROP Reports Institute of Nuclear Power Operations (INPO)

Page 1 of 2 09/01/2015 10:21:47 Report 22 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site Hatch Inspection / Activity Plan 09/01/2015 - 06/30/2017 ASM EP

- 2015 EP ASM & RES BASELINE

1, 2 IP Drill Evaluation 7111406 01/01/2015 12/31/2015 CDBI

- COMPONENT DESIGN BASES INSPECTION

1, 2 IP Component Design Bases Inspection 7111121 08/31/2015 09/04/2015 1, 2 IP Component Design Bases Inspection 7111121 09/21/2015 09/25/2015 1, 2 IP Component Design Bases Inspection 7111121 10/05/2015 10/09/2015 1, 2 IP Component Design Bases Inspection 7111121 10/19/2015 10/23/2015 PI&R

- PROBLEM IDENTIFICATION AND RESOLUTION

1, 2 IP Problem Identification and Resolution 71152B 11/16/2015 11/20/2015 1, 2 IP Problem Identification and Resolution 71152B 12/07/2015 12/11/2015 EP

- EP EXERCISE

1, 2 IP Exercise Evaluation 7111401 12/07/2015 12/11/2015 1, 2 IP Emergency Action Level and Emergency Plan Changes 7111404 12/07/2015 12/11/2015 1, 2 IP Performance Indicator Verification 71151 12/07/2015 12/11/2015 ASM EP

- 2016 EP ASM & RES BASELINE

1, 2 IP Drill Evaluation 7111406 01/01/2016 12/31/2016 RP

- RAD HAZARDS AND TRANSPORTATION

1, 2 IP Radiological Hazard Assessment and Exposure Controls 71124.01 02/08/2016 02/12/2016 1, 2 IP Radioactive Solid Waste Processing and Radioactive Material Handling, Storage, and Transportation 71124.08 02/08/2016 02/12/2016 ISI

- UNIT 1 IN-SERVICE INSPECTION

1 IP Inservice Inspection Activities - BWR 7111108G 02/15/2016 02/19/2016 TFPI

- TRIENNIAL FIRE PROTECTION INSPECTION

1, 2 IP Fire Protection [Triennial]

7111105T 04/04/2016 04/08/2016 1, 2 IP Fire Protection [Triennial]

7111105T 04/18/2016 04/22/2016 OL EXAM

- INITIAL LICENSE EXAM PREP

1 HATCH JUNE 2016 INITIAL EXAM AT POWER FACILITIES V23473 05/23/2016 05/27/2016 MODS

- PLANT MODIFICATIONS INSPECTION

1, 2 IP Evaluations of Changes, Tests, and Experiments and Permanent Plant Modifications 7111117T 06/06/2016 06/10/2016 1, 2 IP Evaluations of Changes, Tests, and Experiments and Permanent Plant Modifications 7111117T 06/20/2016 06/24/2016 RP

- RP PUBLIC RAD SAFETY BASELINE

1, 2 IP Radioactive Gaseous and Liquid Effluent Treatment 71124.06 06/06/2016 06/10/2016 1, 2 IP Radiological Environmental Monitoring Program 71124.07 06/06/2016 06/10/2016 1, 2 IP Performance Indicator Verification 71151 06/06/2016 06/10/2016 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Enclosure

Page 2 of 2 09/01/2015 10:21:47 Report 22 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site Hatch Inspection / Activity Plan 09/01/2015 - 06/30/2017 OL EXAM

- INITIAL LICENSE EXAM

1 HATCH JUNE 2016 INITIAL EXAM AT POWER FACILITIES V23473 06/20/2016 07/01/2016 HS

- TRIENNIAL HEAT SINK PERFORMANCE

1, 2 IP Heat Sink Performance 7111107T 07/25/2016 07/29/2016 OL RQ

- REQUAL INSP

1, 2 IP Licensed Operator Requalification Program 7111111B 08/22/2016 10/21/2016 EP

- EP PROGRAM INSPECTION

1, 2 IP Alert and Notification System Testing 7111402 11/28/2016 12/02/2016 1, 2 IP Emergency Preparedness Organization Staffing and Augmentation System 7111403 11/28/2016 12/02/2016 1, 2 IP Emergency Action Level and Emergency Plan Changes 7111404 11/28/2016 12/02/2016 1, 2 IP Correction of Emergency Preparedness Weaknesses and Deficiencies 7111405 11/28/2016 12/02/2016 1, 2 IP Performance Indicator Verification 71151 11/28/2016 12/02/2016 RP

- RP OCCUPATIONAL INSPECTION WEEK 1

1, 2 IP Radiological Hazard Assessment and Exposure Controls 71124.01 02/06/2017 02/10/2017 1, 2 IP Occupational ALARA Planning and Controls 71124.02 02/06/2017 02/10/2017 1, 2 IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 02/06/2017 02/10/2017 1, 2 IP Occupational Dose Assessment 71124.04 02/06/2017 02/10/2017 1, 2 IP Radiation Monitoring Instrumentation 71124.05 02/06/2017 02/10/2017 1, 2 IP Performance Indicator Verification 71151 02/06/2017 02/10/2017 ISI

- UNIT 2 IN-SERVICE INSPECTION

2 IP Inservice Inspection Activities - BWR 7111108G 02/13/2017 02/17/2017 LR

- UNIT 2 POST APPROVAL LR PHASE 1

1 IP Post-Approval Site Inspection for License Renewal 71003 02/13/2017 02/17/2017 RP

- RP OCCUPATIONAL INSPECTION WEEK 2

1, 2 IP Radiological Hazard Assessment and Exposure Controls 71124.01 02/27/2017 03/03/2017 1, 2 IP Occupational ALARA Planning and Controls 71124.02 02/27/2017 03/03/2017 1, 2 IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 02/27/2017 03/03/2017 1, 2 IP Occupational Dose Assessment 71124.04 02/27/2017 03/03/2017 1, 2 IP Radiation Monitoring Instrumentation 71124.05 02/27/2017 03/03/2017 1, 2 IP Performance Indicator Verification 71151 02/27/2017 03/03/2017 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Enclosure