IR 05000272/2016404

From kanterella
(Redirected from IR 05000354/2016404)
Jump to navigation Jump to search
IR 05000354/2016404, 05000272/2016404, 05000311/2016404; 07/11/2016 to 07/15/2016; Salem Nuclear Generating Station, Units 1 and 2 and Hope Creek Generating Station; Baseline Security Inspection; Equipment Performance, Testing, Maintenance
ML16229A500
Person / Time
Site: Salem, Hope Creek  PSEG icon.png
Issue date: 08/16/2016
From: Raymond Mckinley
Division of Reactor Safety I
To: Sena P
Public Service Enterprise Group
References
IR 2016404
Download: ML16229A500 (4)


Text

ust 16, 2016

SUBJECT:

HOPE CREEK GENERATING STATION AND SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2 - NRC SECURITY INSPECTION REPORT 05000354/2016404, 05000272/2016404, AND 05000311/2016404

Dear Mr. Sena:

On July 15, 2016, the U.S. Nuclear Regulatory Commission (NRC) completed a security inspection at your Hope Creek Generating Station and Salem Nuclear Generating Station, Units 1 and 2. The NRC inspectors discussed the results of this inspection with Ms. Anndria Gaerity, Executive Director of Corporate Services, and other members of your staff. Inspectors documented the results of this inspection in the enclosed inspection report.

NRC inspectors documented two findings of very low security significance (Green) in this report.

These findings involved violations of NRC requirements. The NRC is treating these violations as non-cited violations (NCV) consistent with Section 2.3.2.a of the Enforcement Policy. If you contest these violations or their significance, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555 0001; with copies to the Regional Administrator, Region I; the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, Washington, DC 20555 0001; and the NRC resident inspectors at Hope Creek Generating Station and Salem Nuclear Generating Station, Units 1 and 2.

One cross-cutting aspect was assigned to a finding in the area of Resources, because PSEG failed to ensure that equipment and procedures were adequate to support nuclear safety [H.1].

Additionally, one cross-cutting aspect was assigned to a finding in the area of Field Presence, because PSEG failed to ensure that deviations from standards and expectations are corrected promptly [H.2]. If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the Regional Administrator, Region I; and the NRC resident inspectors Hope Creek Generating Station and Salem Nuclear Generating Station, Units 1 and 2.

Enclosure contains Sensitive Unclassified Non-Safeguards Information. When separated from enclosure, the transmittal document is decontrolled. In accordance with Title 10 of the Code of Federal Regulations (CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding, of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRCs Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS.

If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response Security-Related Information-Withhold from public disclosure under 10 CFR 2.390 in accordance with 10 CFR 2.390(d)(1)

and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.

Sincerely,

/RA/

Raymond R. McKinley, Chief Plant Support Branch 1 Division of Reactor Safety Docket Nos. 50-354, 50-272, and 50-311 License Nos. NPF-57, DPR-70, and DPR-75 Nonpublic Enclosure:

Inspection Report 05000354/2016404, 05000272/2016404, and 05000311/2016404 w/Attachment: Supplemental Information (OUO-SRI)

cc w/o encl; w/o OUO-SRI: Distribution via ListServ cc w/encl; w/OUO-SRI:

P. Davison, Vice President Hope Creek E. Carr, Vice President, Salem R. DeSanctis, Director Security P. Baldauf, Director, NJ Radiation Protection Programs F. Fisher-Tyler, Administrator, Office of Radiation Control, DE Division of Public Health ML16229A500 (Cover letter) ADAMS ACCESSION NUMBER: ML16229A469 (Cover letter w/encl)

Cover Letter: Non-Sensitive Publicly Available SUNSI Review Sensitive Non-Publicly Available Cover Letter w/ Enclosure: Non-Sensitive Publicly Available SUNSI Review Sensitive Non-Publicly Available OFFICE RI/DRS RI/DRS RI/DRS RI/DRP RI/DRS NAME SMcCarver JRey DCaron FBower RMcKinley DATE 08/1/16 08/1/16 08/1/16 08/1/16 08/16/16 3 Letter to Mr. Peter Sena from Mr. Raymond McKinley SUBJECT: HOPE CREEK GENERATING STATION AND SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2 - NRC SECURITY INSPECTION REPORT 05000354/2016404, 05000272/2016404 AND 05000311/2016404 Distribution w/o encl; w/o OUO-SRI: (via E-Mail)

DDorman, RA DLew, DRA MScott, DRP DPelton, DRP RLorson, DRS PKrohn, DRS FBower, DRP RBarkley, DRP MDraxton, DRP RVadella, DRP JHawkins, DRP, SRI PFinney, DRP, SRI SHaney, DRP, RI ASiwy, DRP RI COtt, DRP, AA JBowen, RI, OEDO RidsNrrPMHopeCreek Resource RidsNrrPMSalem Resource RidsNrrDorlLpl1-2 Resource ROPreports Resource Distribution w/encl; w/OUO-SRI: (via E-Mail)

DCaron, DRS RMcKinley, DRS FBower, DRP JHawkins, DRP, SRI PFinney, DRP, SRI NSimonian, NSIR EWharton, NSIR CJohnson, NSIR BDesai, DRS, RII SOrth, DRS, RIII MHaire, DRS, RIV