March 4, 2015

SUBJECT:

ANNUAL ASSESSMENT LETTER FOR BRUNSWICK STEAM ELECTRIC PLANT, UNITS 1 AND 2 - NRC INSPECTION REPORT 05000325/2014001 AND 05000324/2014001

Dear Mr. Gideon:

On February 11, 2015, the NRC completed its end-of-cycle performance review of the Brunswick Steam Electric Plant, Units 1 and 2. The NRC reviewed the most recent quarterly performance indicators (PIs) in addition to inspection results and enforcement actions from January 1, 2014, through December 31, 2014. This letter informs you of the NRCs assessment of your facility during this period and its plans for future inspections at your facility.

The NRC determined that overall, Brunswick Steam Electric Plant, Units 1 and 2 operated in a manner that preserved public health and safety and met all cornerstone objectives. The NRC determined the performance at Brunswick Steam Electric Plant, Units 1 and 2 during the most recent quarter was within the Licensee Response Column of the NRCs Reactor Oversight Process (ROP) Action Matrix because all inspection findings had very low (i.e., green) safety significance, and all PIs indicated that your performance was within the nominal, expected range (i.e., green). Therefore, the NRC plans to conduct ROP baseline inspections at your facility.

The enclosed inspection plan lists the inspections scheduled through June 30, 2016. Routine inspections performed by resident inspectors are not included in the inspection plan. The inspections listed during the last nine months of the inspection plan are tentative and may be revised at the mid-cycle performance review. The NRC provides the inspection plan to allow for the resolution of any scheduling conflicts and personnel availability issues. The NRC will contact you as soon as possible to discuss changes to the inspection plan should circumstances warrant any changes. This inspection plan does not include security-related inspections, which will be sent via separate, non-publicly available correspondence.

We also plan on conducting the following infrequently performed inspections and temporary instructions: Operator Licensing Exams; TI 2515/190: Inspection of the Licensees Proposed Interim Actions as a Result of the Near-Term Task Force Recommendation 2.1 Flooding Evaluation; and TI 2515/191: Inspection of the Implementation of Mitigation Strategies and Spent Fuel Pool Instrumentation Orders and Emergency Preparedness Communication/Staffing/Multi-Unit Dose Assessment Plans. In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Document Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Please contact me 404-997-4645 with any questions you may have regarding this letter.

Sincerely,

/RA/

George T. Hopper, Chief

Reactor Projects Branch 4

Division of Reactor Projects

Docket Nos.: 50-325, 50-324 License Nos.: DPR-71, DPR-62

Enclosure: Brunswick Inspection/Activity Plan (03/01/2015 - 06/30/2016)

cc Distribution via ListServ

_________________________

SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE DRP:RII DRP:RII DRP:RII

SIGNATURE DXW4 JSD GTH

NAME D. Jackson J. Dodson G. Hopper

DATE 02/ 13 /2015 03/04/2015 02/20/2015

E-MAIL COPY?

YES NO YES NO YES NO Letter to William from George T. Hopper dated March 4, 2015.

SUBJECT: ANNUAL ASSESSMENT LETTER FOR BRUNSWICK STEAM ELECTRIC PLANT, UNITS 1 AND 2 - NRC INSPECTION REPORT 05000325/2014001 AND 05000324/2014001

DISTRIBUTION:

D. Gamberoni, RII L. Gibson, RII OE Mail RIDSNRRDIRS PUBLIC RidsNrrPMBrunswick Resource ROP Assessment ROP Reports Institute of Nuclear Power Operations (INPO)

Page 1 of 2 03/04/2015 09:39:23 Report 22 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site Brunswick Inspection / Activity Plan 03/01/2015 - 06/30/2016 ISI

- UNIT 2 IN-SERVICE INSPECTION

2 IP Inservice Inspection Activities - BWR 7111108G 03/02/2015 03/06/2015 RP

- RP OCCUPATIONAL BASELINE WEEK 1

1, 2 IP Radiological Hazard Assessment and Exposure Controls 71124.01 03/02/2015 03/06/2015 1, 2 IP Occupational ALARA Planning and Controls 71124.02 03/02/2015 03/06/2015 1, 2 IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 03/02/2015 03/06/2015 1, 2 IP Occupational Dose Assessment 71124.04 03/02/2015 03/06/2015 1, 2 IP Radiation Monitoring Instrumentation 71124.05 03/02/2015 03/06/2015 1, 2 IP Performance Indicator Verification 71151 03/02/2015 03/06/2015 RP

- RP OCCUPATIONAL BASELINE WEEK 2

1, 2 IP Radiological Hazard Assessment and Exposure Controls 71124.01 03/16/2015 03/20/2015 1, 2 IP Occupational ALARA Planning and Controls 71124.02 03/16/2015 03/20/2015 1, 2 IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 03/16/2015 03/20/2015 1, 2 IP Occupational Dose Assessment 71124.04 03/16/2015 03/20/2015 1, 2 IP Radiation Monitoring Instrumentation 71124.05 03/16/2015 03/20/2015 1, 2 IP Performance Indicator Verification 71151 03/16/2015 03/20/2015 PI&R

- PROBLEM IDENTIFICATION AND RESOLUTION

1, 2 IP Problem Identification and Resolution 71152B 05/04/2015 05/08/2015 1, 2 IP Problem Identification and Resolution 71152B 05/18/2015 05/22/2015 HS

- TRIENNIAL HEAT SINK PERFORMANCE

1, 2 IP Heat Sink Performance 7111107T 07/20/2015 07/24/2015 EP

- EP PROGRAM INSPECTION

1, 2 IP Alert and Notification System Testing 7111402 08/17/2015 08/21/2015 1, 2 IP Emergency Preparedness Organization Staffing and Augmentation System 7111403 08/17/2015 08/21/2015 1, 2 IP Emergency Action Level and Emergency Plan Changes 7111404 08/17/2015 08/21/2015 1, 2 IP Correction of Emergency Preparedness Weaknesses and Deficiencies 7111405 08/17/2015 08/21/2015 1, 2 IP Performance Indicator Verification 71151 08/17/2015 08/21/2015 OL EXAM

- INITIAL LICENSE EXAM PREP

1 BRUNSWICK/NOVEMBER 2015 INITIAL EXAM AT POWER FACILITIES V23431 11/02/2015 11/06/2015 OL EXAM

- INITIAL LICENSE EXAM

1 BRUNSWICK/NOVEMBER 2015 INITIAL EXAM AT POWER FACILITIES V23431 11/30/2015 12/11/2015 ISI

- UNIT 1 IN-SERVICE INSPECTION

1 IP Inservice Inspection Activities - BWR 7111108G 02/22/2016 02/26/2016 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Enclosure

Page 2 of 2 03/04/2015 09:39:23 Report 22 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site Brunswick Inspection / Activity Plan 03/01/2015 - 06/30/2016 RP

- RAD HAZARDS AND TRANSPORTATION

1, 2 IP Radiological Hazard Assessment and Exposure Controls 71124.01 02/22/2016 02/26/2016 1, 2 IP Radioactive Solid Waste Processing and Radioactive Material Handling, Storage, and Transportation 71124.08 02/22/2016 02/26/2016 OL EXAM

- INITIAL LICENSE EXAM PREP

1 BRUNSWICK MAY 2016 INITIAL EXAM AT POWER FACILITIES V23464 04/04/2016 04/08/2016 OL EXAM

- INITIAL LICENSE EXAM

1 BRUNSWICK MAY 2016 INITIAL EXAM AT POWER FACILITIES V23464 05/02/2016 05/13/2016 RP

- RP PUBLIC RAD SAFETY BASELINE

1, 2 IP Radioactive Gaseous and Liquid Effluent Treatment 71124.06 05/23/2016 05/27/2016 1, 2 IP Radiological Environmental Monitoring Program 71124.07 05/23/2016 05/27/2016 1, 2 IP Performance Indicator Verification 71151 05/23/2016 05/27/2016 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.