IR 05000313/1993028

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Repts 50-313/93-28 & 50-368/93-28 on 930920-24.Noncited Violation Identified.Major Areas Inspected:Licensee Physical Security Program & Followup on Corrective Actions for Previous Violations
ML20057G179
Person / Time
Site: Arkansas Nuclear  
Issue date: 10/13/1993
From: Murray B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML20057G178 List:
References
50-313-93-28, 50-368-93-28, NUDOCS 9310210002
Download: ML20057G179 (2)


Text

,

i

!

,

DOCUMENT CONTAINS

! '

APPENDIX U.S. NUCLEAR REGULATORY COMMISSION

REGION IV

Inspection Reports:

50-313/93-28 50-368/93-28

.

'

Operating Licenses: DRP-51 NPF-6 Licensee:

Entergy Operations, Inc.

Route 3, Box 137G Russellville, Arkansas 72801 Facility Name: Arkansas Nuclear One, Units 1 and 2 Inspection At:

Russellville, Arkansas

>

Inspection Conducted: September 20-24, 1993 r

Inspectors: A; B. Earnest, Physical Security Specialist Facilities Inspection Programs Section

[0!O!fl Approved:

f. (,

d1

)jy-Blaine Murray, Chief Date'

Facilities Inspection Programs Section Inspection Summar_y Areas Inspected (Units 1 and 2): Routine, announced inspection of the licensee's physical security program and followup on corrective actions for previous violations.

Results (Units 1 and 2):

lhe licensee had a very good records and report program.

The security

incident reports were excellent (Section 1.1).

The test and maintenance program was excellent (Section 1.2).

  • The test of the emergency power supply indicated that the system

performed well (Section 1.3).

DOCUMENT CONTAINS ENCLOSURE CONTAINS UPON SEPARATION THIS PAGE IS DECONTROLLEO 9310210002 931013 PDR ADOCK 05000313

,

G PDR i

.

-2-DOCUMENT CONTAINS The personnel access control program was excellent (Section 1.4).

e A very efficient program was established for searching packages and

material (Section 1.5).

'

A good program was in place to provide control of vehicles inside the

protected area (Section 1.6).

'

The compensatory measures program was efficiently implemented. The

security officers were well trained on the program requirements (Section 1.7).

A non-cited violation was identified regarding the issaance of security

keys during ncn-emergency conditions. Two concerns were identified regarding the large number of security key and key depositories in use and the method used for the inventory security keys (Section 1.8).

Summary of Inspection Findinas:

A non-cited violation was identified (Section 1.8).

Violation 313/9312-01; 368/9312-01 was closed (Section 2.1)

i Attachment:

Attachment - Persons contacted and exit meeting.

.

[

,

DOCUMENT CONTAINS ENCLOSURE CONTAINS UPON SEPARATION THIS PAGE IS DECONTROLLED