IR 05000312/1978021

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 50-312/78-21 on 781127-29.No Items of Noncompliance Noted
ML19305A178
Person / Time
Site: Rancho Seco
Issue date: 12/07/1978
From: Spencer G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
Shared Package
ML19305A179 List:
References
NUDOCS 7901120001
Download: ML19305A178 (2)


Text

'

a

e

,

' '

r,1,

'W ' Il f)

,T g,

g

~

i NUCLEAH REGUGTOH< ' T; '.

D,m g

' $'

ll f PJ c, son v

,

.O e.--,#

[

S U l1 E 2 '11

.N A L N U T C R t r d vt -?>

11'30 'd C Alli o P'41 A U O U L F 'r 14 0

++

e*

W A L P, U T C R E E K. C / Li f 0 9141 T*

91334 DEC 7 W73 Docket flo. 50-312 Sacramento flunicipal Utility District P. O. Box 15830 Sacramento, California 95813 Attention: fir. John J.11attimoe Assistant General flar.ager Gentlemen:

Subject:

Inspection of Sacramento flunicipal Utility District Rancho Seco This refers to the inspection conducted by 14essrs. T. W. Bishop and P. P. flarbut of this office on flovember 27-29, 1978 of activities authorized by iiRC Licente fio. DPR-54, and to the discussion of our findings with fir. R. J. Rodriguez and other members of your staff at the conclusion of the inspection.

Areas examined during this inspection are described in the enclosed inspection report.

Within these areas, the inspection consisted of selective examinations of procedures and representative records, inter-views with personnel, and observations by the inspectors.

tio items of noncompliance with tiRC requirements were identified within the scope of this inspection.

In accordance with Section 2.790 of the tiRC's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the flRC's Public Docunent Room.

If this report contains any information that you believe to be proprietary, it is necessary that you submit a written application to this office, within 20 days of the date of this letter, requesting that such infornation be withheld from public disclosure.

The applica-tion must include a full statement of the reasons why it is claimed that the information is proprietary. The apolication should be prepared so that any proprietary information identified is contained in an enclosure 790112os n i

'

..'

DF.C 7 19,,

Sacreento Municipal Utili ty Distr :-t-2-to the application, since the application without the enclosure will also be placed in the Public Document Rocca.

If we do not hear from you in this regard within the specified-period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be glad to discuss them with you.

Sincerely,

,

14.yuct v G. S. Sp ncer, Chief Reactor Construction and Engineering Support Branch Enclosure:

IE Inspection Report flo. 50-312/78-21 cc w/o enclosure:

R. J. Rodriguez, SMUD L. G. Schweiger, SMUD R. W. Columbo, SMUD

'

'

.

.

'

.

s

,

.

DETAILS 1.

Iridividuals Contacted a.

Sacramento Municipal Utility District (SMUD)

  • R. J. Rodriguez, Manager, Nuclear Operations
  • R. Oubre, Plant Superintendent
  • J. V. McColligan, Technical Supervisor
  • L. G. Schwieger, QA Director
  • U. B. Garrett, Plant Mechnical Engineer
  • J. Sullivan, Senior Quality Engineer W. Ford, Operations Supervisor b.

Babcock and Wilcox Construction Company (B&W)

H. Stoppelman, ISI Supervisor J. '.larwick, QA/QC Supervisor c.

g:rtford Steam Boiler Insurance Company K. Eshleman, Authorized Inspector

  • Denotes those attending the exit interview.

2.

Review of Inservice Inspection (ISI) Program Plans Rancho Seco is in its first 40-month inservice inspection period.

Governing code editions for the program are the 1971 ASME Section XI through summer of 1973 Addenda for Code Class 1 items and 1974 ASME Section XI through summer of 1975 Addenda for Code Class 2 and 3 piping.

The inservice inspection was being conducted in conjunc-tioa with the second refueling cutage. The licensee's program for this segment of the ISI was defined in two documents.

Surveillance Procedure No. SP-207.07 provided the inspection plan for the steam generators and Special Test Procedure No. STP-068 provided the plan for ISI of components other than steam generators.

Those portions of the licensee's ISI program which varied signifi-cantly from the previous year's plan (addrersed in NRC Report 50-312/77-13) were reviewed for compliance to the governing code edi tions.

,

.

-2-

,

,

.

-

.

il0 items of noncompliance or deviations were identified.

The

-

inspector did note, however, that a visual examination had not been identified for certain portions of ASME Code Class 3 reacter coolant pump cooling water lines.

Licensee representatives stated instructions would be issued to perform a visual examination of these lines during hydrostatic testing of the lines prior to start-up.

Licensee representatives further stated that a review would be performed of other Code Class 3 systems to assure all pertinent ISI requirements are met.

The inspector had no further questions at that time and this item will be re-examined during a subsequent inspection.

(50-312/78-21/01)

3.

Review of Quality Implementing Procedures The following ISI procedures were reviewed in regards to proper appr, oval, personnel qualifications, procedure scope, technical adequacy, and records requirements:

a.

Procedure ISI 120, Revision 6 of 3-7-78, Ultrasonic Exam-

<ination of Class 1 and 2 Piping Welds Joining Similar and Dissimilar Materials b.

Procedure ISI 240, Revision 3 of 5-20-77, Penetrant Exam-ination of Weld and Base Materials Including Studs, Nuts and Washers c.

Procedure ISI 270, Revision 4 of 5-20-77, Wet or Dry Methods of Magnetic Particle Examination of Welds, Studs, Nuts, Bolts, Washers and Pump Motor Flywheels d.

Procedure ISI 300, Revision 8-29-78, Radiographic Examination of Welds and Base Materials.

The procedures were found to be in compliance with the governing ASME code requirecents.

flo items of noncompliance or deviations were identified.

4.

Observation of Work and Work Activitie_s The following nondestructive ISI exaninations were witnessed by the inspectors:

a.

Wet fluorescent magnetic particle examinations of reactor vessel studs in accordance with Procedure ISI-270, Revision 4.

The examination of one stud was observed in its entirety.

The examination of a second stud was observed partially (STP-058 examination No. Bl.8.2).

-3-

'

.-

,

.

.

.

,

b.

Ultrasonic examination of reactor coolant system hot leg S elbow to high point vent bimetallic boss held in accordance with Procedure ISI 120 (STP-063 examination No. 84.1.72)

c.

Liquid penetrant examination of reactor coolant system hot leg A elbow to high point vent binetallic boss weld in ac-cordance with Procedure ISI 240 (STP-068 examination No.

B4.1.28)

The examinations were conducted in accordance with applicable procedures.

No 1tems of noncompliance or deviations were identi-fied.

5.

Data Review and Evaluation The inspector reviewed and evaluated the following nondestructive test data records for compliance with requirements of the governing ASME code.

a.

Examination B4.1.4, ultrasonic examination of pressurizer relief nozzle to SE-XY axis.

b.

Examination B4.1.5, liquid penetrant examination of pressurizer relief nozzle to SE-XY axis.

c.

Examination 84.1.6, visual inspection of pressurizer relief nozzle to SE-XY axis, d.

Examination B5.1.4, visual inspection of reactor coolant pump S studs.

e.

Records of liquid penetrant examination fluid certifications.

f.

Records of personnel qualifications for one level I, one level II and one level III nondestructive test examiner.

g.

ISI visual examination records of Code Class 3 nuclear service raw water system piping, WR-31885.

h.

ISI visual examination records of Code Class 3 main steam to auxiliary feed pump turbine piping, WR-31884.

The inspector found these records, to be complete and consistent with the code with one exception; namely, the records for visual examination of Code Class 3 piping, items 5.g and 5.h above, did not clearly indicate the scope of the inspection performed.

Dis-cussiens with personnel responsible for the inspections established that the inspections were limited to a visual surveillance for

.'

-

_g.

.

-

.

.

leakage, and did not specifically include observations of structural distress or corrosion as required by the code.

Licensee repre-sentatives stated that each of the Code Class 3 piping visual inspections would be repeated prior to startup and would encompass all inspection attributes required by the code.

This item will be re-examined during a subsequent inspection.

(50-312/78-21/02)

6.

Audits The SMUD audit of the B&W organization conducted in June 1978 and the preliminary results of the SMUD audit of B&W ISI activities were examined. The audits included training and qualification of personnel, control and approval of procedures, maintenance and calibration of NDE equipment, control of records, and conduct of B&W audits.

Two B&W audits of ISI activities at Rancho Seco were also examined.

One finding (lack of UT calibration records) was identified by the audits and was properly resolved (UT calibration and examination was repeated). Additional actions to prevent recurrence are under B&W review.

The scope and planning of audits was found to be consistent with QA manual requirements.

No items of noncompliance or deviations were identified.

7.

Exit Interview The inspectors met with licensee representatives denoted in Para-graph 1.

The activities covered during the inspection and ob-servations and findings of the inspectors were discussed.

Licensee representatives stated that immediate action would be taken to resolve the findings identified.