IR 05000263/1978018

From kanterella
Jump to navigation Jump to search
IE Insp Rept 50-263/78-18 on 781105-08.Noncompliance Noted: Access Control.Details Withheld (Ref 10CFR2.790)
ML19263B226
Person / Time
Site: Monticello 
Issue date: 12/27/1978
From: Cogburn J, Creed J, Hind J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19263B224 List:
References
50-263-78-18, NUDOCS 7901150033
Download: ML19263B226 (1)


Text

.

.

-

.

-.*

.

U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFCRCEMENT

REGION III

.

.

Report No. 50-263/78-18 Docket No. 50-263 License No. DPR-22 Safeguards Group Licensee: Northern States Power Company 414 Nicollet Mall Minneapolis, MN 55401 Facility Name: Monticello Nuclear Generating Plant Inspection At: Monticello Site, Monticello, MN Inspection Conducted: November 5-8, 1978

  • Id [~.

j(g/ 2 7/'7 r _

Inspectors:

J. R.

( d k

e f'

l-:!7'

J. M. Cogburn L

,

f.7 l...,

J A.

in'd Chie i) L7f7(

,

_.

Approved By:

/

Safeguards Brancht Inspection Summarv

.

Insoection on November 5-8, 1978 (Report No. 50-263/78-18)

Areas Inspected: Unannounced inspection regarding:

(a) action taken by the licensee to correct previous inspection findings identified during an inspection conducted June 27-30, 1978; (b) applicable procedural ay 25, 1977; (c)

requirements of 10 CFR 73.55, which became effective w

applicable portions of the approved Monticello Security Plan (Rev. 4);

(d) licensee action relative to IE Circular No. 78-17.

Specifically, the inspectors reviewed the security organization, physical barriers, access controls, communications controls, detection aids, testing and maintenance of security related equipment, response requirements and records. The inspection involved 59 inspector-hours onsite by two NRC

-

it.spectors.

Results: Of the eight areas specifically inspected, one item of non-compliance was identified in one area - (Access Controls, paragraph 5).

This item is considered a deficiency. The previous inspection finding is considered closed. One unresolved item was identified relative to the Security Organization.

Details (Part 2.790(d) Information)

7 90115 0 0 333L

.