Category:INSPECTION REPORT
MONTHYEARIR 05000263/19990061999-10-21021 October 1999 Insp Rept 50-263/99-06 on 990813-0923.Non-cited Violations Noted.Major Areas Inspected:Operations,Engineering, Maintenance & Plant Support IR 05000263/19990121999-10-13013 October 1999 Insp Rept 50-263/99-12 on 990913-17.No Violations Noted. Major Areas Inspected:Various Aspects of RP Program Including Radioactive Waste Processing,Storage,Packaging & Transportation & General RP Practices IR 05000263/19990051999-09-0101 September 1999 Insp Rept 50-263/99-05 on 990702-0812.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000263/19990041999-07-28028 July 1999 Insp Rept 50-263/99-04 on 990521-0701.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19990111999-07-14014 July 1999 Insp Rept 50-263/99-11 on 990621-24.No Violations Noted. Major Areas Inspected:Licensee Performance During Exercise of Emergency Plan IR 05000263/19990021999-05-0303 May 1999 Insp Rept 50-263/99-02 on 990223-0408.One Violation Occurred & Being Treated as non-cited Violation.Major Areas Inpsected:Operations,Engineering,Maint & Plant Support IR 05000263/19990101999-04-0909 April 1999 Insp Rept 50-263/99-10 on 990308-12.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures & Operating Exam Matls & Observation & Evaluation of Licensed Operators IR 05000263/19990011999-03-11011 March 1999 Insp Rept 50-263/99-01 on 990112-0222.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19980181999-01-20020 January 1999 Insp Rept 50-263/98-18 on 981201-990111.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980191998-12-30030 December 1998 Insp Rept 50-263/98-19 on 981214-18.No Violations Noted. Major Areas Inspected:Review of Various Aspects of Licensees Chemistry & Radiation Protection Programs,Specifically REMP, PASS & Chemistry QC & Matl Condition IR 05000263/19980161998-12-14014 December 1998 Insp Rept 50-263/98-16 on 981014-1130.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Performance of Emergency Preparedness Drill IR 05000263/19980171998-11-24024 November 1998 Insp Rept 50-263/98-17 on 981026-30.No Violations Noted. Major Areas Inspected:Physical Security Program IR 05000263/19980151998-11-10010 November 1998 Insp Rept 50-263/98-15 on 980821-1014.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000263/19980121998-09-18018 September 1998 Insp Rept 50-263/98-12 on 980719-0831.No Violations Noted. Major Areas Inspected:Opertions,Maint,Engineering & Plant Support IR 05000263/19980131998-09-11011 September 1998 Insp Rept 50-263/98-13 on 980810-13.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Nuclear Power Plants IR 05000263/19980141998-09-0404 September 1998 Insp Rept 50-263/98-14 on 980810-14.No Violations Noted. Major Areas Inspected:Licensee Liquid & Gaseous Effluents Program,Calibration & Testing of Area & Process Radiation Monitors & Free Release Program IR 05000263/19980111998-08-21021 August 1998 Insp Rept 50-263/98-11 on 980528-0718.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980091998-07-30030 July 1998 Insp Rept 50-263/98-09 on 980511-0612.No Violations Noted. Major Areas Inspected:Review of 10CFR50.59 Safety Evaluation & Screening Activities IR 05000263/19980071998-06-25025 June 1998 Insp Rept 50-263/98-07 on 980413-0527.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19980101998-05-26026 May 1998 Insp Rept 50-263/98-10 on 980427-30.No Violations Noted. Major Areas Inspected:Plant Support IR 05000263/19980061998-05-11011 May 1998 Insp Rept 50-263/98-06 on 980323-0423.No Violations Noted. Major Areas Inspected:Maint IR 05000263/19980041998-05-0808 May 1998 Insp Rept 50-263/98-04 on 980224-0414.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000263/19980081998-04-30030 April 1998 Insp Rept 50-263/98-08 on 980406-09.No Violations Noted. Major Areas Inspected:Radiation Protection Activities During Refueling & Maint Outage ML20216B2871998-04-0303 April 1998 Insp Rept 50-263/98-05 on 980309-13.Violations Noted.Major Areas Inspected:Physical Security Program ML20217A6881998-03-18018 March 1998 Insp Rept 50-263/98-02 on 980113-0223.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C1671998-03-0606 March 1998 Insp Rept 50-263/98-03 on 980209-13.Violations Noted.Major Areas Inspected:Various Aspects of Licensee RP Program Including Radwaste Processing,Packaging,Transportation & Implementation of Recent Changes to NRC & DOT Regulations IR 05000263/19970181998-02-0404 February 1998 Insp Rept 50-263/97-18 on 971125-980112.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198G3171998-01-0606 January 1998 Page 6 of Plant Emergency Preparedness Exercise Insp Rept 50-263/97-16.Page Inadvertently Omitted W/Rept Transmitted by IR 05000263/19970161997-12-22022 December 1997 Insp Rept 50-263/97-16 on 971118-21.No Violations Noted. Major Areas Inspected:Evaluation of Performance During Plant Biennial Exercise of Emergency Plan by Regional EP Inspectors & Resident Inspector Staff from Plants ML20197B1731997-12-18018 December 1997 Insp Rept 50-263/97-15 on 971014-1124.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970171997-12-15015 December 1997 Insp Rept 50-263/97-17 on 971118-21.No Violations Noted. Major Areas Inspected:General Radiation Protection Practices,Respiratory Protection Program & Radwaste Processing,Storage & Monitoring IR 05000263/19970141997-11-13013 November 1997 Insp Rept 50-263/97-14 on 970830-1013.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support.Rept Also Includes Insp follow-up of Security Related Issue by Regional Inspector IR 05000263/19970121997-09-18018 September 1997 Insp Rept 50-263/97-12 on 970708-0829.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970111997-08-19019 August 1997 Insp Rept 50-263/97-11 on 970707-10.No Violations Noted. Major Areas Inspected:Installation of Emergency Core Cooling Sys Suction Strainers & pressure-suppression Chamber Coating Program IR 05000263/19970131997-08-14014 August 1997 Forwards Partially Withheld Insp Rept 50-263/97-13 on 970714-18 (Ref 10CFR73.21) IR 05000263/19970101997-07-23023 July 1997 Insp Rept 50-263/97-10 on 970623-27.No Violations Noted. Major Areas Inspected:Review of Issues Surrounding Licensee Discovery of Error in Head Loss Across ECCS Suction Strainers ML20149H9291997-07-17017 July 1997 Insp Rept 50-263/97-08 on 970528-0707.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970091997-07-15015 July 1997 Insp Rept 50-263/97-09 on 970616-20.No Violations Noted. Major Areas Inspected:Licensees Chemistry & Radiation Protection Programs ML20141E8031997-06-18018 June 1997 Insp Rept 50-263/97-06 on 970412-0527.Violation Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19970031997-05-0909 May 1997 Insp Rept 50-263/97-03 on 970220-0411.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970041997-04-14014 April 1997 Insp Rept 50-263/97-04 on 970310-14.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures,Operating Exam Matl,Observation & Operating Exam, & Assessment of Simulator Fidelity ML20137K1881997-03-24024 March 1997 Corrected Pages 23,39,50 & 51 to Insp Rept 50-263/96-09,in Order to Correct Errors in Rept ML20137A1681997-03-11011 March 1997 Insp Rept 50-263/97-02 on 970109-0219.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20138N6991997-02-20020 February 1997 Insp Rept 50-263/96-09 on 961118-970108.Violations Noted. Major Areas Inspected:Maintenance,Engineering & Operations IR 05000263/19960121997-01-31031 January 1997 Insp Rept 50-263/96-12 on 961128-970108.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20134G1611997-01-29029 January 1997 Insp Rept 50-263/96-11 on 961017-1127.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133C4081996-12-27027 December 1996 Insp Rept 50-263/96-08 on 960829-1016.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19960101996-11-0101 November 1996 Insp Rept 50-263/96-10 on 961028-1101.No Violations Noted. Major Areas Inspected:Status of Radiation Protection & Chemistry Controls IR 05000263/19960071996-10-0707 October 1996 Insp Rept 50-263/96-07 on 960721-0828.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20058H4431993-12-0606 December 1993 Rept 50-263/93-20 on 931202.Areas Discussed:Review of Circumstances Surrounding & Corrective Actions in Response to Licensee Identified Incident of Inadequate Storage & Marking of Safeguards Info at Plant 1999-09-01
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000263/19990061999-10-21021 October 1999 Insp Rept 50-263/99-06 on 990813-0923.Non-cited Violations Noted.Major Areas Inspected:Operations,Engineering, Maintenance & Plant Support IR 05000263/19990121999-10-13013 October 1999 Insp Rept 50-263/99-12 on 990913-17.No Violations Noted. Major Areas Inspected:Various Aspects of RP Program Including Radioactive Waste Processing,Storage,Packaging & Transportation & General RP Practices IR 05000263/19990051999-09-0101 September 1999 Insp Rept 50-263/99-05 on 990702-0812.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000263/19990041999-07-28028 July 1999 Insp Rept 50-263/99-04 on 990521-0701.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19990111999-07-14014 July 1999 Insp Rept 50-263/99-11 on 990621-24.No Violations Noted. Major Areas Inspected:Licensee Performance During Exercise of Emergency Plan IR 05000263/19990021999-05-0303 May 1999 Insp Rept 50-263/99-02 on 990223-0408.One Violation Occurred & Being Treated as non-cited Violation.Major Areas Inpsected:Operations,Engineering,Maint & Plant Support IR 05000263/19990101999-04-0909 April 1999 Insp Rept 50-263/99-10 on 990308-12.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures & Operating Exam Matls & Observation & Evaluation of Licensed Operators IR 05000263/19990011999-03-11011 March 1999 Insp Rept 50-263/99-01 on 990112-0222.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19980181999-01-20020 January 1999 Insp Rept 50-263/98-18 on 981201-990111.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980191998-12-30030 December 1998 Insp Rept 50-263/98-19 on 981214-18.No Violations Noted. Major Areas Inspected:Review of Various Aspects of Licensees Chemistry & Radiation Protection Programs,Specifically REMP, PASS & Chemistry QC & Matl Condition IR 05000263/19980161998-12-14014 December 1998 Insp Rept 50-263/98-16 on 981014-1130.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Performance of Emergency Preparedness Drill IR 05000263/19980171998-11-24024 November 1998 Insp Rept 50-263/98-17 on 981026-30.No Violations Noted. Major Areas Inspected:Physical Security Program IR 05000263/19980151998-11-10010 November 1998 Insp Rept 50-263/98-15 on 980821-1014.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000263/19980121998-09-18018 September 1998 Insp Rept 50-263/98-12 on 980719-0831.No Violations Noted. Major Areas Inspected:Opertions,Maint,Engineering & Plant Support IR 05000263/19980131998-09-11011 September 1998 Insp Rept 50-263/98-13 on 980810-13.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Nuclear Power Plants IR 05000263/19980141998-09-0404 September 1998 Insp Rept 50-263/98-14 on 980810-14.No Violations Noted. Major Areas Inspected:Licensee Liquid & Gaseous Effluents Program,Calibration & Testing of Area & Process Radiation Monitors & Free Release Program IR 05000263/19980111998-08-21021 August 1998 Insp Rept 50-263/98-11 on 980528-0718.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980091998-07-30030 July 1998 Insp Rept 50-263/98-09 on 980511-0612.No Violations Noted. Major Areas Inspected:Review of 10CFR50.59 Safety Evaluation & Screening Activities IR 05000263/19980071998-06-25025 June 1998 Insp Rept 50-263/98-07 on 980413-0527.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19980101998-05-26026 May 1998 Insp Rept 50-263/98-10 on 980427-30.No Violations Noted. Major Areas Inspected:Plant Support IR 05000263/19980061998-05-11011 May 1998 Insp Rept 50-263/98-06 on 980323-0423.No Violations Noted. Major Areas Inspected:Maint IR 05000263/19980041998-05-0808 May 1998 Insp Rept 50-263/98-04 on 980224-0414.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000263/19980081998-04-30030 April 1998 Insp Rept 50-263/98-08 on 980406-09.No Violations Noted. Major Areas Inspected:Radiation Protection Activities During Refueling & Maint Outage ML20216B2871998-04-0303 April 1998 Insp Rept 50-263/98-05 on 980309-13.Violations Noted.Major Areas Inspected:Physical Security Program ML20217A6881998-03-18018 March 1998 Insp Rept 50-263/98-02 on 980113-0223.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20216C1671998-03-0606 March 1998 Insp Rept 50-263/98-03 on 980209-13.Violations Noted.Major Areas Inspected:Various Aspects of Licensee RP Program Including Radwaste Processing,Packaging,Transportation & Implementation of Recent Changes to NRC & DOT Regulations IR 05000263/19970181998-02-0404 February 1998 Insp Rept 50-263/97-18 on 971125-980112.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198G3171998-01-0606 January 1998 Page 6 of Plant Emergency Preparedness Exercise Insp Rept 50-263/97-16.Page Inadvertently Omitted W/Rept Transmitted by IR 05000263/19970161997-12-22022 December 1997 Insp Rept 50-263/97-16 on 971118-21.No Violations Noted. Major Areas Inspected:Evaluation of Performance During Plant Biennial Exercise of Emergency Plan by Regional EP Inspectors & Resident Inspector Staff from Plants ML20197B1731997-12-18018 December 1997 Insp Rept 50-263/97-15 on 971014-1124.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970171997-12-15015 December 1997 Insp Rept 50-263/97-17 on 971118-21.No Violations Noted. Major Areas Inspected:General Radiation Protection Practices,Respiratory Protection Program & Radwaste Processing,Storage & Monitoring IR 05000263/19970141997-11-13013 November 1997 Insp Rept 50-263/97-14 on 970830-1013.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support.Rept Also Includes Insp follow-up of Security Related Issue by Regional Inspector IR 05000263/19970121997-09-18018 September 1997 Insp Rept 50-263/97-12 on 970708-0829.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970111997-08-19019 August 1997 Insp Rept 50-263/97-11 on 970707-10.No Violations Noted. Major Areas Inspected:Installation of Emergency Core Cooling Sys Suction Strainers & pressure-suppression Chamber Coating Program IR 05000263/19970131997-08-14014 August 1997 Forwards Partially Withheld Insp Rept 50-263/97-13 on 970714-18 (Ref 10CFR73.21) IR 05000263/19970101997-07-23023 July 1997 Insp Rept 50-263/97-10 on 970623-27.No Violations Noted. Major Areas Inspected:Review of Issues Surrounding Licensee Discovery of Error in Head Loss Across ECCS Suction Strainers ML20149H9291997-07-17017 July 1997 Insp Rept 50-263/97-08 on 970528-0707.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970091997-07-15015 July 1997 Insp Rept 50-263/97-09 on 970616-20.No Violations Noted. Major Areas Inspected:Licensees Chemistry & Radiation Protection Programs ML20141E8031997-06-18018 June 1997 Insp Rept 50-263/97-06 on 970412-0527.Violation Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19970031997-05-0909 May 1997 Insp Rept 50-263/97-03 on 970220-0411.No Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 05000263/19970041997-04-14014 April 1997 Insp Rept 50-263/97-04 on 970310-14.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures,Operating Exam Matl,Observation & Operating Exam, & Assessment of Simulator Fidelity ML20137K1881997-03-24024 March 1997 Corrected Pages 23,39,50 & 51 to Insp Rept 50-263/96-09,in Order to Correct Errors in Rept ML20137A1681997-03-11011 March 1997 Insp Rept 50-263/97-02 on 970109-0219.Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20138N6991997-02-20020 February 1997 Insp Rept 50-263/96-09 on 961118-970108.Violations Noted. Major Areas Inspected:Maintenance,Engineering & Operations IR 05000263/19960121997-01-31031 January 1997 Insp Rept 50-263/96-12 on 961128-970108.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20134G1611997-01-29029 January 1997 Insp Rept 50-263/96-11 on 961017-1127.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20133C4081996-12-27027 December 1996 Insp Rept 50-263/96-08 on 960829-1016.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19960101996-11-0101 November 1996 Insp Rept 50-263/96-10 on 961028-1101.No Violations Noted. Major Areas Inspected:Status of Radiation Protection & Chemistry Controls IR 05000263/19960071996-10-0707 October 1996 Insp Rept 50-263/96-07 on 960721-0828.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20058H4431993-12-0606 December 1993 Rept 50-263/93-20 on 931202.Areas Discussed:Review of Circumstances Surrounding & Corrective Actions in Response to Licensee Identified Incident of Inadequate Storage & Marking of Safeguards Info at Plant 1999-09-01
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000263/19990061999-10-21021 October 1999 Insp Rept 50-263/99-06 on 990813-0923.Non-cited Violations Noted.Major Areas Inspected:Operations,Engineering, Maintenance & Plant Support IR 05000263/19990121999-10-13013 October 1999 Insp Rept 50-263/99-12 on 990913-17.No Violations Noted. Major Areas Inspected:Various Aspects of RP Program Including Radioactive Waste Processing,Storage,Packaging & Transportation & General RP Practices IR 05000263/19993011999-09-27027 September 1999 NRC Operator Licensing Exam Rept 50-263/99-301(including Completed & Graded Tests) for Tests Administered on 990823-26.Both Applicants Passed All Sections of Exam IR 05000263/19990051999-09-0101 September 1999 Insp Rept 50-263/99-05 on 990702-0812.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering, Maint & Plant Support IR 05000263/19990041999-07-28028 July 1999 Insp Rept 50-263/99-04 on 990521-0701.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19990111999-07-14014 July 1999 Insp Rept 50-263/99-11 on 990621-24.No Violations Noted. Major Areas Inspected:Licensee Performance During Exercise of Emergency Plan IR 05000263/19990021999-05-0303 May 1999 Insp Rept 50-263/99-02 on 990223-0408.One Violation Occurred & Being Treated as non-cited Violation.Major Areas Inpsected:Operations,Engineering,Maint & Plant Support IR 05000263/19990101999-04-0909 April 1999 Insp Rept 50-263/99-10 on 990308-12.No Violations Noted. Major Areas Inspected:Review of Training Administrative Procedures & Operating Exam Matls & Observation & Evaluation of Licensed Operators IR 05000263/19990011999-03-11011 March 1999 Insp Rept 50-263/99-01 on 990112-0222.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000263/19980181999-01-20020 January 1999 Insp Rept 50-263/98-18 on 981201-990111.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980191998-12-30030 December 1998 Insp Rept 50-263/98-19 on 981214-18.No Violations Noted. Major Areas Inspected:Review of Various Aspects of Licensees Chemistry & Radiation Protection Programs,Specifically REMP, PASS & Chemistry QC & Matl Condition IR 05000263/19980161998-12-14014 December 1998 Insp Rept 50-263/98-16 on 981014-1130.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support Re Performance of Emergency Preparedness Drill ML20198B7851998-12-14014 December 1998 Notice of Violation from Insp on 981014-1130.Violation Noted:As of 981113,several Fire Brigade Personnel Not Listed as Qualified Fire Brigade Members Had Not Participated in Required Number of Fire Brigade Drills IR 05000263/19980171998-11-24024 November 1998 Insp Rept 50-263/98-17 on 981026-30.No Violations Noted. Major Areas Inspected:Physical Security Program IR 05000263/19980151998-11-10010 November 1998 Insp Rept 50-263/98-15 on 980821-1014.No Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support IR 05000263/19980121998-09-18018 September 1998 Insp Rept 50-263/98-12 on 980719-0831.No Violations Noted. Major Areas Inspected:Opertions,Maint,Engineering & Plant Support IR 05000263/19980131998-09-11011 September 1998 Insp Rept 50-263/98-13 on 980810-13.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maint at Nuclear Power Plants IR 05000263/19980141998-09-0404 September 1998 Insp Rept 50-263/98-14 on 980810-14.No Violations Noted. Major Areas Inspected:Licensee Liquid & Gaseous Effluents Program,Calibration & Testing of Area & Process Radiation Monitors & Free Release Program IR 05000263/19980991998-08-26026 August 1998 SALP Rept 50-263/98-99 for Monticello Nuclear Generating Plant,Covering Period from 960721-980718 IR 05000263/19980111998-08-21021 August 1998 Insp Rept 50-263/98-11 on 980528-0718.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19980091998-07-30030 July 1998 Insp Rept 50-263/98-09 on 980511-0612.No Violations Noted. Major Areas Inspected:Review of 10CFR50.59 Safety Evaluation & Screening Activities IR 05000263/19980071998-06-25025 June 1998 Insp Rept 50-263/98-07 on 980413-0527.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Support IR 05000263/19980101998-05-26026 May 1998 Insp Rept 50-263/98-10 on 980427-30.No Violations Noted. Major Areas Inspected:Plant Support IR 05000263/19980061998-05-11011 May 1998 Insp Rept 50-263/98-06 on 980323-0423.No Violations Noted. Major Areas Inspected:Maint IR 05000263/19980041998-05-0808 May 1998 Insp Rept 50-263/98-04 on 980224-0414.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support IR 05000263/19980081998-04-30030 April 1998 Insp Rept 50-263/98-08 on 980406-09.No Violations Noted. Major Areas Inspected:Radiation Protection Activities During Refueling & Maint Outage ML20247M5311998-04-13013 April 1998 EN-98-026:on 980420,informs Commission That NRC Will Exercise Enforcement Discretion Per Section VII.B.6 of Enforcement Policy & Not Issue NOV or Propose Civil Penalty to Northern States Power Co for Two Violations W/Rhr ML20216B2871998-04-0303 April 1998 Insp Rept 50-263/98-05 on 980309-13.Violations Noted.Major Areas Inspected:Physical Security Program ML20217A6881998-03-18018 March 1998 Insp Rept 50-263/98-02 on 980113-0223.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20217A6751998-03-18018 March 1998 Notice of Violation from Insp on 980113-0223.Violation Noted:Inspectors Identified That Shift Supervisor Failed to Remove hold-and-secure Card Attached to Control Room hand- Switch for Number 13 ML20216C1521998-03-0606 March 1998 Notice of Violation from Insp on 980209-13.Violation Noted: on 971028,licensee Did Not Make Surveys to Assure Compliance w/10CFR20.1201(a),which Limits Occupational Radiation Exposure ML20216C1671998-03-0606 March 1998 Insp Rept 50-263/98-03 on 980209-13.Violations Noted.Major Areas Inspected:Various Aspects of Licensee RP Program Including Radwaste Processing,Packaging,Transportation & Implementation of Recent Changes to NRC & DOT Regulations IR 05000263/19970181998-02-0404 February 1998 Insp Rept 50-263/97-18 on 971125-980112.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20198G3171998-01-0606 January 1998 Page 6 of Plant Emergency Preparedness Exercise Insp Rept 50-263/97-16.Page Inadvertently Omitted W/Rept Transmitted by IR 05000263/19970161997-12-22022 December 1997 Insp Rept 50-263/97-16 on 971118-21.No Violations Noted. Major Areas Inspected:Evaluation of Performance During Plant Biennial Exercise of Emergency Plan by Regional EP Inspectors & Resident Inspector Staff from Plants ML20197B1731997-12-18018 December 1997 Insp Rept 50-263/97-15 on 971014-1124.Violations Noted. Major Areas Inspected:Operations,Maint & Engineering IR 07100014/20110241997-12-18018 December 1997 Notice of Violation from Insp on 971014-1124.Violation Noted:Activities Affecting Quality Were Not Accomplished in Accordance W/Documented Procedures IR 05000263/19970171997-12-15015 December 1997 Insp Rept 50-263/97-17 on 971118-21.No Violations Noted. Major Areas Inspected:General Radiation Protection Practices,Respiratory Protection Program & Radwaste Processing,Storage & Monitoring ML20199E5871997-11-13013 November 1997 Notice of Violation from Insp on 970830-1013.Violation Noted:From 960229-970410,northwest Corner of Established Vehicle Barrier Sys Not Adequate to Protect Against Use of Land Vehicle in That Barrier Not Continuous IR 05000263/19970141997-11-13013 November 1997 Insp Rept 50-263/97-14 on 970830-1013.Violations Noted. Major Areas Inspected:Operations,Maintenance,Engineering & Plant Support.Rept Also Includes Insp follow-up of Security Related Issue by Regional Inspector IR 05000263/19970121997-09-18018 September 1997 Insp Rept 50-263/97-12 on 970708-0829.No Violations Noted. Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support IR 05000263/19970111997-08-19019 August 1997 Insp Rept 50-263/97-11 on 970707-10.No Violations Noted. Major Areas Inspected:Installation of Emergency Core Cooling Sys Suction Strainers & pressure-suppression Chamber Coating Program IR 05000263/19970131997-08-14014 August 1997 Forwards Partially Withheld Insp Rept 50-263/97-13 on 970714-18 (Ref 10CFR73.21) IR 05000263/19970101997-07-23023 July 1997 Insp Rept 50-263/97-10 on 970623-27.No Violations Noted. Major Areas Inspected:Review of Issues Surrounding Licensee Discovery of Error in Head Loss Across ECCS Suction Strainers ML20149H9291997-07-17017 July 1997 Insp Rept 50-263/97-08 on 970528-0707.Violations Noted.Major Areas Inspected:Licensee Operations,Engineering,Maint & Plant Support ML20149H9221997-07-17017 July 1997 Notice of Violation from Insp on 970528-0707.Violation Noted:Reactor Bldg Closed Cooling Water Valve 2-2 & Associated Piping Removed from Pump,However,Safety Tag on Valve Had Not Been Properly Released IR 05000263/19970091997-07-15015 July 1997 Insp Rept 50-263/97-09 on 970616-20.No Violations Noted. Major Areas Inspected:Licensees Chemistry & Radiation Protection Programs ML20141E8031997-06-18018 June 1997 Insp Rept 50-263/97-06 on 970412-0527.Violation Noted.Major Areas Inspected:Operations,Engineering,Maint & Plant Support ML20141E7961997-06-18018 June 1997 Notice of Violation from Insp on 970412-0527.Violation Noted:Inspectors Identified That Operations Personnel Did Not Know That Number 13 ESW Pump Had Been Operating for 2 Days Following 970408 Loss of Power to Number 15 4160 Volt PNO-III-97-046, on 970516,WI Energy Co & Northern States Power Co Announced They Were Terminating Plans for Proposed Merger of Two Companies Into New Co,Primergy Corp.Utils Attributed Decision to Changing Regulatory Policies1997-05-16016 May 1997 PNO-III-97-046:on 970516,WI Energy Co & Northern States Power Co Announced They Were Terminating Plans for Proposed Merger of Two Companies Into New Co,Primergy Corp.Utils Attributed Decision to Changing Regulatory Policies 1999-09-27
[Table view] |
Text
_
<*
+.
!
( U.S. NUCLEAR REGULATORY COMMISSION
!
-
0FFICE OF INSPECTION AND ENFORCEMENT J
.
REGION III j
Report No. 50-263/78-04 Docket No. 50-263 License No. DPR-22 Licenseek Northern States Power Company 414 Nicollet Mall Minneapolis, MN 55401 )
l Facility name: Monticello Nuclear Generating Station Inspection at: Monticello Site and Minneapolis Corporate Offices l Inspection conducted: March 14-16, 1978 ,
Inspectors: en @
- '
s. .Au&Q sua
-
4/s/1e 6L h Y W Approved by: .Nssig, ef Environmental and Special ;
Projects Section
&
Inspection Summary Inspection on March 14-16, 1978 (Report No. 50-263/78-04) '
Areas Inspected: Routine, unannounced inspection of environmental '
protection including licensee internal audits; management control programs; control of quality in analytical measurements; and implemen-tation of radiological and nonradiological environmental monitoring l i
programs. The inspection involved 30 inspector-hours by two NRC inspector '
Results: No items of noncompliance or deviations were identified in any of the five areas inspecte :
.
i
( '
-
9102070568 780406 4 CF ADOCK 05000263 >
HM CF_
_. .. . . . .
. .- - - . - . - - - _ .-_i
_m , ,. . - . _ -_ m e.. .s.... - . . . . s_ - _ .
.,.
.
.
i , .
-
,
DETAILS
,
. l Persons Contacted
- ,
- Mr. L. O. Mayer, Manager, Nuclear Support Services (NSS) !
] *Mr. E. L. Ward, Manager, Nuclear Environmental Services, NSS Mr. B. W. Clark, Administrator, Radiation Environnental ,
!
'
Monitoring, NSS Mr. G. Heberling, Supervisor, Ecological Studies (Monti-Sherco) !
'
Environmental - Govermental Activities Department (EGAD)
j Mr. D. Johnson, Environmental Aide,-EGAD -
1 Mr. J. Weinhold, Field Biologist, EGAD i
] Mr. F. Fey, Radiation Protection Supervisor, Monticello Plant ;
i Mr. R. Jacobsen, Plant Chemist, Monticello Plant
$
j * denotes those present at the exit intervie ,
a ;
'
2 Licensee Internal Audits
'
a The inspectors reviewed documentation concerning an audit of the contractor performing radiological environmental monitoring, which ,
was conducted jointly by a technical member from the licensee's
'
Nuclear Support Services Department and a quality assurance member j from the Quality Assurance Departmen This audit, conducted in ,
'
i ( June,1977, covered the quality assurance program being implemented i by the environmental contractor in comparison to the criteria of
- 10 CFR 50. Appendix The quality assurance program was developed ,
, pursuant to contract agreements, and had as its basis the applicable i portions of Appendix B.- l l
t i The licensee audit identified a nuuber of minor inconsistencies j for which the inspectors reviewed licensee followup actio The licensee had subdivided audit findings by significance, and directed i the contractor to take. corrective action and report in writing for
,
three items. Corrective action had.been completed, and identified deficiencies resolved, at the time of this inspection. None of the
'
deficiencies identified involved compliance matters.
J l No items of noncompliance or deviations were identifie i
, Management Control
i The inspectors reviewed licensee assignments of responsibility I
'
and authority for program management, review, and audit of the l
'
radiological and'nonractological environmental monitoring l
!
'
!
( :
-2- l
l
.
I
- -. . _
l
e k
k programs. These assignments, previously delegated by internal memoranda, are now formalized in licensee Administrative Control
'
Directives (ACD's) in accordance with the licensee's current l quality assurance documentation policie The Environmental - Govermental Activities Department (EGAD) is assigned responsibility for sample collection, pretreatment and shipping for radiological environmental samples. EGAD also operates, maintains and calibrates air sampling stations for this program.
'
Forfthe nonradiological environmental monitoring program, the licensee does not have technical specifications but conducts a voluntary study. Development and conduct of this study, including collection, analysis and evaluation, and preparation of study reports, are responsibilities assigned to EGA Responsibility for operation and maintenance of meteorological field data collection equipment has been transferred from EGAD to the Monticello plant staf The Nuclear Support Services (NSS) Department is responsible under the current ACD's for development and maintenance of the radiological environmental monitoring program, including manage-ment of the contract for radiological sample analysis. Respon- '
sibilities for report preparation and submittal, and for conduct i of an independent audit program are also assigned to NS Computer reduction and processing of meteorological data and development of dose pathway models are NSS responsibilities relating to the meteorological monitoring progra No items of noncompliance or deviations were identifie . Analytical Quality Control The inspectors examined licensee programs to assure quality in collection and analysis of samples for the radiological environ-mental monitoring progra Detailed sampling procedures have been developed to assure collection of all samples and to control integrity and representativeness of the samples collected by EGAD personne Records establishing implementation of these procedures were reviewed, with no problems noted. In addition, a combination audit and training program is carried out through occasional NSS ' accompaniment of the EGAD staff on field sample collectio (
-3-
. . -.
_ __ -_
l i
l
.
&
Analytical quality control,; as noted in Paragraph 2 above, is achieved through contractor , implementation of his own quality control program. The contractor's quality assurance and quality l control program manuals have been provided to and reviewed by the licensee, and have been approved for use in the contract program. The licensee is kept informed of revisions to either manua The contractor provides quality control program data to the licensee as part of the normal analytical data reporting proces These data are reviewed by NSS personnel along with data from the sampling program. At the time of this inspection, the
,
licensee was soliciting information from the contractor concerning ,
'
the comprehensiveness of the quality control data provided during calendar year 197 ;
- No items of noncompliance or deviations were identifie . Radiological Monitoring Program Implementation t The inspectors reviewed licensee implementation of the radio-
,
logical environmental monitoring program for calendar year 197 Both raw data reports and the final summary report were examine No unusual results or trends ascribable to operation of the Monticello plant were observed in this review. The Radiation
'
( Environmental Monitoring Program (REMP) did identify numerous samples showing deposition of radioactive debris from atmos-pheric nuclear weapons testing conducted by the People's Republic of China in late 1976 and again in September, 1977. The licensee has selected indicator nuclides for use in discriminating weapons fallout from plant effluent effects, and provides a referenced analysis and basis fer each determination where quantifiable levels of radioactivity were observed in environmental media.
The data showed very few instances of missed analyses, and each of these was provided with a reasonable justificatio During this inspection, three REMP sample collection stations i
were visited. Each was found to be located as specified and to be in good working order. The licensee's program for collection station maintenance and calibration was discussed i with licensee personnel. An excellent air sampling station operability record has been achieve No items of noncompliance or deviations were identifie (
,
-4-
u
.
.
(- 6. Nonradiological Monitoring Program Implementation As previously noted, the licEhsee does not have Appendix B Technical Specifications covering detailed program conduct j for the nonradiological environmental monitoring progra ]
'
The voluntary program conducted by the licensee was reviewed during the inspection to maintain cognizance of program statu In addition, the licensee's formal program report for calendar year 1976 was reviewed and discussed with licensee personnel, as were modifications to the program carried out in 197 .-
The nonradiological monitoring program has included the fol-Iowing specific studies: attached algae (periphyton); water quality; macroinvertebrates; fish creel surveys; electrofishing; and fish impingement. During 1977, the macroinvertebrate studies were terminated on the recommendation of the consultant performing the work. He concluded a sufficient data base had been established, such that additional expense was unlikely to garner information of value. Also in 1977, a fish seining survey was added to the ecological program. This continuing study is intended to 2 qualify types of species present and to provide abundance indices i
by year class. The fish impingement program was a one-year
+ intensive study performed by a contract consultant. This study was completed in May, 197 No items of noncompliance or deviations were identifie !
(
7. Management Interview A management interview (with licensee representatives as indicated in paragraph 1) was conducted at the conclusion of the inspection on March 16, 1978. The inspectors summarized the scope and findings of the inspection, specifically noting that no problems
had been identified. The licensee requested early coordination with NSS staff following the initiation of future unannounced environmental inspections.
d
{ !
-5-
.