FEB 0 41986
,
florida Power and Light Company t/ ATTN: Mr. C. O. Woody Group Vice President Nuclear Energy Department P. O. Box 14000 Juno Beach, FL 33408 Gentlemen:
SUBJECT: CONFIRMATORY MEASUREMENTS RESULTS DOCKET NOS. 50-250 AND 50-251 As part ~of the NRC Confirmatory Measurements Program, and supplemental to Inspection Reports 50-250/84-32 and 50-251/84-33, spiked liquid samples were sent on July 22, 1985, to your Turkey Point facility for selected radiochemical analyses. We are in receipt of your analytical results transmitted to us by your
. letter L-85-369.
Verification of reported data values were discussed-with members of your staff on December 16, 1985.
Provided as Enclosure 1 is a comparison of your reported results to the known values. The acceptance criteria for the comparisons are listed in Enclosure 2.
In our review of these dat'a, all comparative results were in agreement. These
'
data should be reviewed in greater detail by cognizant staff members for any significant trends in the data among successive years in which samples have been analyzed by your facility. Any biases noted may be indicative of a programmatic weakness and your efforts should be put forth in determining reasons for such -
biases.
These results and any results from previous years pertaining to these analyses will be discussed at future NRC inspections.
Sincerely, cAi9tMI 990d by VinWN d ?onCUL Vincent W. Panciera, Acting Chief Reactor Projects Branch 2 Division of Reactor Projects Enclosures:
1.
Confirmatory. Measurement Comparisons 2.
Criteria for Comparing Analytical Measurements cc w/encls:
(See page 2)
8602100274 060204 (
PDR ADOCK 05000250 G
'
}
i.t (
'
ZE0 /
+-..,.
f.
A.
.g y,
',,
F1orida Power and Light Company
,
s
..
-pC.M.Wethy,<VicePresident w/encis:
Turkey Point Nuclear Plant X
'd-J. Baker,PlantManager
.d.'TurkeyPointNuclearPlant J..Acosta, Plant QA Superintendent j. Arias, Jr., Regulatory and Compliance
'
Supervisor
-
,
'
I;/cc w/encis:
WRC Resident Inspector Document Control Desk.
State of Florida
" f.,,,
j s
e i
"i
!
'JHarris C ne DCollins S rod f411/)/86
)
1//6/86-1/
1/2ffB6
t e
.
.
- .
Lt(Cl0SUREj CONFIRMAIORY HEASUREMENT COMPARISONS OF H-3, FE-55, SR-89, AND SR-90 ANALVSIS FOR IURKEY PolNT NUCLEAR PLANT ON JULY 22, 1985 190 tope Licensee NRC Resolution Ratio Compa r i son (uCi/ unit)
(uCi/ unit)
(Licensee /NRC)
H-3 3.09 E-5 2.981.06 E-5
1.01 Ag reement 1.011.02 E-5
1.06 Ag reemen t Fe-55 1.101.06 E-5
Sr-89 1.19 t.05 E-te 1.251.084 E-14
.85 Ag reement Sr-90 1.13t.008 E-5 1.381.06 E-5
.82 Agreement
.
W f
.
.
ENCLOSURE 2 CRITERIA FOR COMPARING ANALYTICAL MEASUREMENTS This enclosure provides criteria for comparing results of capability tests and verification measurements.
The criteria are based on an empirical relationship which combines prior experience and the accuracy needs of this program.
In these criteria, the judgement limits denoting' agreement or disagreement between licensee and NRC results are variable. This variability is a function of the NRC's value relative to its associated uncertainty. As the ratio of the NRC value to its associated uncertainty, referred to in this program as
" Resolution"2 increases, the range of acceptable differences between the NRC and licensee values should be more restrictive. Conversely, poorer agreement between NRC and licensee values must be considered acceptable as the resolution decreases.
For comparison purposes, a ratio of the licensee value to the NRC value for each
individual nucTide is computed. This ratio is then evaluated for agreement based on the calculated resolution. The corresponding resolution and calculated ratios which denote agreement are listed in Table 1 below.
Values outside of the agreement ratios for a selected nuclides are considered in disagreement.
NRC Reference Value for a particular Nuclide 2 Resolution = Associated Uncertainty for the Value Licensee Value 2 Comparison Ratio = NRC Reference Value TABLE 1 - Confirmatory Measurements Acceptance Criteria Resolutions vs. Comparison Ratio Comparison Ratio for Resolution Agreement
<4 0.4. - 2.5 4-7 0.5. - 2.0 8 - 15 0.6 - 1.66 16 - 50 0.75 - 1.33 51 - 200 0.80 - 1.25
>200 0.85 - 1.18