{{#Wiki_filter:- -- . -..._.. . O ~ ' . 9.5. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT Region I . Report No. 40-2940/80-02 . Docket No.
40-2940 License No.
.SUC-346 Priority Category , Licensee: N. 1. Industries Inc.
1130 Central Avenue Albany, New York 12205 Facility Name: Shipment ' Inspection at: Beatty, Nevads Inspection conducted: March 21, 1980 Inspectors: See attached report cover sheet date signed
date signed - date signed Approved by: See attached report cover sheet date signed i Inspection Summary: See attached report cover sheet
. 9007140h) Region I Form 12 (Rev. April 77).
, , .. - , - -. -, - --- ,vm-, -,,,- ..., - - _, - - -, -, - _ _, _ -
_ - - _ _ _ _.
- -. - - - - - , - , . . . . U. S. NUCLEAR REGUIATORY C0!ctISSION
OFFICE OF INSPECTION AND ENFORCEMENT
REGION V
80-38 R port No.
Dseket No.
15000027 License No.
Safeguards Group Licensee: . Fccility Name: Nucler Engineering Co.
Inspection at: Beatty, Nevada Inspection conducted: fiarch 21, 1980 ' Inspectors: I.[[ N/ $$ c U
- 86 8.A.'RiedlingerjRadiationSpecialist Date Signed
, at Signed Approved by: [ / M R.D. Thomas, ief,tiaterials Radiological date Signed ' I C Approved By:
. H.li. Book, Chief, Fuel Facility & Materials Date Signed ' S(fety Branch Su r ary: Ir.spection on March 21,1980 (Report No. 15000027/80-38) As part of the inspection of incoming shipments of radioactive waste
to NECO, Beatty, Nevada, during March 17 through 21, 1980, this inspection of trailer number 2143 was conducted on fiarch 21, 1980.
No packages were opened. A State of Nevada representative was present during the inspection.
No D0T inspector was onsite during the inspection.
Results: One apparent item f noncompliance with D0T/NRC regulations was observed. See paragraph 3.
It appears that the Department of Transportation, the State of New York, and NRC Region I Office are the appropriate organizations to take enforcement actions.
. ' l RV Fort:2 219 (2) l i _ _ _.. _ _
- - .. . . DETAILS Persons Contacted Steve Carpenter, Site Manager, NECO, Beatty, Nevada Brian Thayer, Assistant Site Manager Jim Cruickshank, Radiation Safety Officer Larry Franks, Nevada State Health Division Background As a part of the inspection of incoming shipments of radioactive waste to NECO, Beatty, Nevada, during March 17 through 21, 1980, this inspection of trailer number 2143 was conducted on March 21, 1980.
Inspection - Licensee - Shipper: NL Industries, Inc.
Albany, New York Shipment Inspected: March 21,1980 Carrier: NL Industries Hightstown, New Jersey . Trailer: 2143 Shipment Number: NEV-03 , 1.
This enclosed trailer transported nine wooden boxes of solid scrap contaminated with U-238. This was an exclusive use shipment.
The trailer was properly placarded.
2.
A vehicle survey showed a maximum dose rate of 1 mR/hr at the surface of the trailer.
Checks for removable radioactive contamination showed no activity in excess of DOT limits.
3.
During unloading, the inspector observed that the side of one box was pulling away from the rest of the container and that a plastic bag inside the box was visible through the gap. A second box in similar condition was later off loaded.
The boxes appeared to be in noncompliance with 49 CFR 173.392 (c)(1) which requires that materials be packed in strong, tight packages so that there will be no leakage of radioactive materials in transit.
4.
Boxes were labeled with '" Radioactive LSA" stickers. The sticker for one box was almost completely removed during unloading, s a --_ - ,_w. }}