Waste Packaging Insp Rept 15000027/80-31 on 800321. Noncompliance Noted:Bottom of Wooden Box for Solid Scrap Containing U-238 Was Pulled Away,Revealing Contents
ML19320B720
Person / Time
Site: 02700010, 015000027, 04002940
Issue date: 04/15/1980
From: Book H, Reidlinger B, Thomas R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
NL CHEMICALS (USA), INC.
Shared Package
ML19320B719 List:
References
15000027-80-31, 40-2940-80-01, 40-2940-80-1, NUDOCS 8007140657
Download: ML19320B720 (3)


Text

.g

-

U.S.~ NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT Region I Report No.

40-2940/80-01 Docket No.

40-2940 License No.

SNM-346 Priority Category Licensee:

N. L. Industries Avenue 1130 Central Avenue

'

Albany, New York 12205 Facility Name:

Shipment Inspection at: Beatty, Nevada Inspection conducted: March 19, 1980 Inspectors:

See attached rennet envor chant date signed

.

date signed date signed Approved by:

See attached reoort cover sheet date signed Inspection Summary:

See attached report cover sheet l

l I

i

!

!

l 8007140bT7 Region I Form 12 (Rev. April 77)

.. -

-

-

. _ -

.

.

-

._.

,

_ - - _ - - _ _ _ -. _ _. -.. _.. _ - - _ _ _ _

.

-

.

,

.

.

U. S. NUCLEAR REGULATORY COMMISSION

'

OFFICE OF INSPECTION AND ENFORCEMENT-

REGION V

Rsporc No.

80-31 Dacket No.

15000027 License No.

Safeguards Group Licensee:

,

!

.

Fccility Name:

Nuclear Engineering Co.

Inspection at:

Beatty, Nevada

.

Inspection conducted:

' March 19,1980 Inspectors:

38. N MM4%i)

h(1[7()

B.A.RiedlingeglRadiationSpecialist Date Signed

,

Dat Signed Approved by:

[

R.D. Thomas, hief, Materials Radiological bate Signed

'

Approved By:

U

-

'

H.E. B'cok, Chief, Fuel Facility and Materials Date Signed Safety Branch Suemary:

Inspection on March 19,1980 (Report No. 15000027/80-31)

As a part of the inspection of. incoming shipments of radioactive waste to NEC0, Beatty, Nevada, during March 17 through 21, 1980 this inspection of trailer number 71519 was conducted on fiarch 19, 1980. No packages were opened. No State of Nevada or DOT representatives were on site.

Results: One apparent item of noncompliance with DOT /NRC regulations was observed. See paragraph 3.,

.

It appears that the Department of Transportation, the State of New York, and NRC Region I Office are the appropriate organizations to take enforcement actions.

-

'

RV Form 219 (2)

.,

.

.

- -, -

/

~

~

-

,j

,

.

.

DETAILS

.

Persons Contacted Steve Carpenter, Site Manager, NECO, Beatty, Nevada Brian Thayer, Assistant Site Manager Jim Cruickshank, Radiation Safety Officer Background As a part of the inspection of incoming shipments of radioactive waste to NECO, Beatty, Nevada, during liarch 17 through 21,1980, this inspection of trailer number 71519 was conducted on March 19, 1980.

Inspection Licensee - Shipper: NL Industries, Inc.

Albany, New York Shipment Inspected: March 19,1980

'

Carrier:

NL Industries Hightstown, New Jersey Trailer:

71519

' Shipment Number:

NEV-02 1.

Inis enclosed trailer transported nine wooden boxes of solid scrap contaminated with U-238. This was an exclusive use shipment. The trailer was properly placarded.

  • 2.

A vehicle survey showed a maximum dose rate of 2 mR/hr at the surface of the trailer.

The cab survey showed a dose rate of 0.5 mR/hr.

Checks for removable radioactive contamination were made of the threshold of the trailer, of three boxes, and of the floor of the trailer after unloading.

None of the checks disclosed removable contamination in excess of DOT limits, 3.

One of the wooden boxes did not have a center support on the bottom.

The bottom of the box was buckled and had pulled away from the sides of the box, revealing some of the contents. This appears to be in noncompliance with 49 CFR 173.392 (c)(1) which requires that materials be packed in strong, tight packages so that there will be no leakage of radioactive materials in transit.

4.

Boxes were labeled with " Radioactive - LSA" stickers. Some of the stickers blew off the boxes during unloading.

.