Below is a summary of a Part 21notification received from the vendor via facsimile:
The vendor, via a testing facility, identified another batch of contaminated hydraulic snubber fluid. The fluid batch number is 16DLVS852, manufactured on 4/17/16 by Momentive Performance Materials, Leverkusen, Germany.
Licensees that were supplied the contaminated fluid were identified as: Palisades, Pilgrim, Browns Ferry and Sequoyah.
Previous batches were identified under the Part 21 process by Lake Engineering Co. as follows:
Batch Number (followed by ADAMS Ascension Number)
AD965 - ML070180491 and ML070300154
ZJS1518 - ML19077A096, ML19136A044 and ML19199A034
11KLVS145 - ML18211A302, ML18295A199, ML19008A043 and ML19071A112
14ELVS145 - ML17128A465, ML17212A628, ML17313A471, ML17355A139 and ML19121A155
For further information, please contact:
Walter Paszul, PE
General / Engineering Manager
E-Mail: walter@fronekgrp.com
Phone No: ( 603) 528-1931
Fax No: ( 603) 528-6381