| Title | Agreement State Report - Radiography Source Disconnected While Working in the Field |
| Event Description | The following report was received from the Texas Department of State Health Service via email:
On October 2, 2017, the Agency [Texas Department of State Health Services] was notified by the licensee that one of its radiography crews had experienced a source disconnect while working at a field site. The radiography crew was using a QSA 880D exposure device containing a 75 curie iridium-192 source. The radiographers had completed a shot and as they approached the exposure device their alarming rate meters alarmed. The radiographers retreated to the end of the crank out device and attempted to retract the source. The source could not be retracted. The radiographers contacted their radiation safety officer (RSO) who responded to the scene. The RSO was able to drive the source into the collimator and place shielding over the source. The RSO inspected the drive cable and found that the drive cable had pulled out of the drive cable connector to the source pigtail. The RSO connected a new crank out device to the source and was able to retract the source into the fully shielded position in the camera. The RSO stated he inspected the drive cable at the connection and it appeared the cable had been stretched. The RSO stated the connector had obvious crimp marks on it. The RSO stated the equipment would be returned to the manufacturer for inspection. No individual received an overexposure due to this event. No member of the general public received any exposure from this event. The Agency has requested additional information from the licensee. Additional information will be provided as it is received in accordance with SA-300. Texas Incident #:I 9515 |
| Where | |
|---|---|
| Acuren Inspection, Inc. Laport, Texas (NRC Region 4) | |
| License number: | 01774 |
| Organization: | Texas Dept Of State Health Services |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+31.25 h1.302 days <br />0.186 weeks <br />0.0428 months <br />) | |
| Opened: | Art Tucker 12:15 Oct 3, 2017 |
| NRC Officer: | Jeff Herrera |
| Last Updated: | Oct 3, 2017 |
| 52997 - NRC Website | |
Acuren Inspection, Inc. with Agreement State | |
WEEKMONTHYEARENS 580092025-10-27T05:00:00027 October 2025 05:00:00
[Table view]Agreement State Worker Potentially Exceeded Occupational Dose Limit ENS 567732023-10-02T20:30:0002 October 2023 20:30:00 Agreement State Disconnected Radiography Source ENS 567682023-09-30T05:00:00030 September 2023 05:00:00 Agreement State Radiography Source Stuck Unshielded and Recovered ENS 566042023-06-30T21:50:00030 June 2023 21:50:00 Agreement State Missing Radiography Camera ENS 559352022-06-11T12:47:00011 June 2022 12:47:00 Agreement State Armed BREAK-IN at Licensed Facility ENS 557912022-03-12T06:00:00012 March 2022 06:00:00 Agreement State Radiography Source Failure to Retract ENS 553662021-07-20T20:30:00020 July 2021 20:30:00 Agreement State Radiography Camera Source Disconnect ENS 551832021-04-08T05:00:0008 April 2021 05:00:00 Agreement State Source Lost During Shipment ENS 550192020-12-02T22:40:0002 December 2020 22:40:00 Agreement State Radiography Source Stuck within Source Guide Tube ENS 529972017-10-02T05:00:0002 October 2017 05:00:00 Agreement State Agreement State Report - Radiography Source Disconnected While Working in the Field ENS 527592017-05-15T05:00:00015 May 2017 05:00:00 Agreement State Agreement State Report - Potential Excessive Exposure of Radiographer ENS 523142016-10-20T05:00:00020 October 2016 05:00:00 Agreement State Agreement State Report - Unable to Retract Radiography Camera Source ENS 523082016-10-19T06:00:00019 October 2016 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 518392016-03-30T04:00:00030 March 2016 04:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 518032016-03-02T17:30:0002 March 2016 17:30:00 Agreement State Agreement State - Radiography Camera Source Unable to Be Retracted ENS 507452015-01-16T21:15:00016 January 2015 21:15:00 Agreement State Agreement State Report - Potential Radiographer Excessive Exposure ENS 502392014-06-29T21:25:00029 June 2014 21:25:00 Agreement State Agreement State Report - Inability to Retract Radiography Source to Its Fully Shielded Position ENS 500142014-04-09T15:30:0009 April 2014 15:30:00 Agreement State Agreement State Report - Radiographer Overexposure ENS 499122014-03-12T05:00:00012 March 2014 05:00:00 Agreement State Texas Agreement State Report - Potential Overexposure to a Radiographer'S Hand ENS 451712009-06-26T15:30:00026 June 2009 15:30:00 Agreement State Agreement State Report - Difficulty Retrieving Radiography Source 2025-10-27T05:00:00 | |