ENS 45171
ENS Event | |
|---|---|
15:30 Jun 26, 2009 | |
| Title | Agreement State Report - Difficulty Retrieving Radiography Source |
| Event Description | The following report was received via facsimile:
Licensee contacted Ohio Department of Health at approx. 3:45 PM on 6/26/09 to report an incident which occurred earlier that day involving the inability to retrieve a radiography source at a job site near Dayton, Ohio. The incident involved a QSA Global Model 880D camera with a 85 Ci Ir-192 source. At approximately 11:30 AM and after several unsuccessful attempts to retrieve the source, the radiography crew secured the area around the source and contacted a trained source recovery individual at their Cincinnati office for assistance. This person arrived at the job site at approx. 12:20 PM and assessed the situation. The recovery person determined that a flange had fallen on the guide tube during the previous shot, which crushed the guide tube and prevented source retrieval. The shot involved a 90-degree bend on a six-inch pipe and the flange was a scrap piece of material found on site that the crew had used to hold the guide tube in place during the shot. It was further determined that the set-up used by the crew for the shot was not very stable, which contributed to the falling of the flange onto the tube. The recovery person was able to retract the source into the camera at approximately 12:45 PM. The licensee determined that there was no exposure to the public or radiography crew as a result of this incident. The radiography crew was reminded to ensure the stability of future shot setups before exposing the source. The guide tube was replaced and work continued. Ohio report number: OH090006 |
| Where | |
|---|---|
| Acuren Inspection, Inc. Dayton, Ohio (NRC Region 3) | |
| License number: | 03320990006 |
| Organization: | Ohio Bureau Of Radiation Protection |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+67.53 h2.814 days <br />0.402 weeks <br />0.0925 months <br />) | |
| Opened: | Stephen James 11:02 Jun 29, 2009 |
| NRC Officer: | Dong Park |
| Last Updated: | Jun 29, 2009 |
| 45171 - NRC Website | |
Acuren Inspection, Inc. with Agreement State | |
WEEKMONTHYEARENS 580092025-10-27T05:00:00027 October 2025 05:00:00
[Table view]Agreement State Worker Potentially Exceeded Occupational Dose Limit ENS 567732023-10-02T20:30:0002 October 2023 20:30:00 Agreement State Disconnected Radiography Source ENS 567682023-09-30T05:00:00030 September 2023 05:00:00 Agreement State Radiography Source Stuck Unshielded and Recovered ENS 566042023-06-30T21:50:00030 June 2023 21:50:00 Agreement State Missing Radiography Camera ENS 559352022-06-11T12:47:00011 June 2022 12:47:00 Agreement State Armed BREAK-IN at Licensed Facility ENS 557912022-03-12T06:00:00012 March 2022 06:00:00 Agreement State Radiography Source Failure to Retract ENS 553662021-07-20T20:30:00020 July 2021 20:30:00 Agreement State Radiography Camera Source Disconnect ENS 551832021-04-08T05:00:0008 April 2021 05:00:00 Agreement State Source Lost During Shipment ENS 550192020-12-02T22:40:0002 December 2020 22:40:00 Agreement State Radiography Source Stuck within Source Guide Tube ENS 529972017-10-02T05:00:0002 October 2017 05:00:00 Agreement State Agreement State Report - Radiography Source Disconnected While Working in the Field ENS 527592017-05-15T05:00:00015 May 2017 05:00:00 Agreement State Agreement State Report - Potential Excessive Exposure of Radiographer ENS 523142016-10-20T05:00:00020 October 2016 05:00:00 Agreement State Agreement State Report - Unable to Retract Radiography Camera Source ENS 523082016-10-19T06:00:00019 October 2016 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 518392016-03-30T04:00:00030 March 2016 04:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 518032016-03-02T17:30:0002 March 2016 17:30:00 Agreement State Agreement State - Radiography Camera Source Unable to Be Retracted ENS 507452015-01-16T21:15:00016 January 2015 21:15:00 Agreement State Agreement State Report - Potential Radiographer Excessive Exposure ENS 502392014-06-29T21:25:00029 June 2014 21:25:00 Agreement State Agreement State Report - Inability to Retract Radiography Source to Its Fully Shielded Position ENS 500142014-04-09T15:30:0009 April 2014 15:30:00 Agreement State Agreement State Report - Radiographer Overexposure ENS 499122014-03-12T05:00:00012 March 2014 05:00:00 Agreement State Texas Agreement State Report - Potential Overexposure to a Radiographer'S Hand ENS 451712009-06-26T15:30:00026 June 2009 15:30:00 Agreement State Agreement State Report - Difficulty Retrieving Radiography Source 2025-10-27T05:00:00 | |