ENS 50239
ENS Event | |
|---|---|
21:25 Jun 29, 2014 | |
| Title | Agreement State Report - Inability to Retract Radiography Source to Its Fully Shielded Position |
| Event Description | The following information was obtained from the Commonwealth of Pennsylvania via fax and email:
Event type: Inability to retract radiography source to its fully shielded position. Notifications: The Department's [Pennsylvania Department of Environmental Protection] Central Office was informed of this event on June 30, 2014. This event is reportable within 24-hours per 10 CFR 34.101(a)(2) and 10 CFR 30.50(b)(2). Event Description: A radiographer and his assistant were performing radiography above ground. During an exposure, the magnet holding the guide tube and collimator in place disengaged and the tube fell between some conduit below. This caused a [sharp] bend in the guide tube [which caused] the source to become lodged in place and un-retractable. The RSO was notified. The area was roped off to prevent unauthorized access and a retrieval team was called in to address the situation. At 5:35 am on June 30, 2014 the retrieval team notified the RSO that the source had been fully retracted. Dosimeter readings indicate no workers were exposed above regulatory limits as a result of this event. All badges are currently being sent for emergency readings. Manufacturer: QSA Global Model: 880 Delta Serial Number: 14678C Isotope: lr-192 Activity: 70.2 Ci Cause of the Event: Undetermined at this time Actions: The camera and all associated equipment used during this event were removed from service and are currently being sent to the manufacturer for evaluation. The department plans a full reactive inspection. More information will be sent upon notification. PA Event Report ID No: PA140013 |
| Where | |
|---|---|
| Acuren Inspection, Inc. Susquehanna, Pennsylvania (NRC Region 1) | |
| License number: | PA-1063 |
| Organization: | Pa Bureau Of Radiation Protection |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+18.08 h0.753 days <br />0.108 weeks <br />0.0248 months <br />) | |
| Opened: | David J. Allard 15:30 Jun 30, 2014 |
| NRC Officer: | Howie Crouch |
| Last Updated: | Jun 30, 2014 |
| 50239 - NRC Website | |
Acuren Inspection, Inc. with Agreement State | |
WEEKMONTHYEARENS 580092025-10-27T05:00:00027 October 2025 05:00:00
[Table view]Agreement State Worker Potentially Exceeded Occupational Dose Limit ENS 567732023-10-02T20:30:0002 October 2023 20:30:00 Agreement State Disconnected Radiography Source ENS 567682023-09-30T05:00:00030 September 2023 05:00:00 Agreement State Radiography Source Stuck Unshielded and Recovered ENS 566042023-06-30T21:50:00030 June 2023 21:50:00 Agreement State Missing Radiography Camera ENS 559352022-06-11T12:47:00011 June 2022 12:47:00 Agreement State Armed BREAK-IN at Licensed Facility ENS 557912022-03-12T06:00:00012 March 2022 06:00:00 Agreement State Radiography Source Failure to Retract ENS 553662021-07-20T20:30:00020 July 2021 20:30:00 Agreement State Radiography Camera Source Disconnect ENS 551832021-04-08T05:00:0008 April 2021 05:00:00 Agreement State Source Lost During Shipment ENS 550192020-12-02T22:40:0002 December 2020 22:40:00 Agreement State Radiography Source Stuck within Source Guide Tube ENS 529972017-10-02T05:00:0002 October 2017 05:00:00 Agreement State Agreement State Report - Radiography Source Disconnected While Working in the Field ENS 527592017-05-15T05:00:00015 May 2017 05:00:00 Agreement State Agreement State Report - Potential Excessive Exposure of Radiographer ENS 523142016-10-20T05:00:00020 October 2016 05:00:00 Agreement State Agreement State Report - Unable to Retract Radiography Camera Source ENS 523082016-10-19T06:00:00019 October 2016 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 518392016-03-30T04:00:00030 March 2016 04:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 518032016-03-02T17:30:0002 March 2016 17:30:00 Agreement State Agreement State - Radiography Camera Source Unable to Be Retracted ENS 507452015-01-16T21:15:00016 January 2015 21:15:00 Agreement State Agreement State Report - Potential Radiographer Excessive Exposure ENS 502392014-06-29T21:25:00029 June 2014 21:25:00 Agreement State Agreement State Report - Inability to Retract Radiography Source to Its Fully Shielded Position ENS 500142014-04-09T15:30:0009 April 2014 15:30:00 Agreement State Agreement State Report - Radiographer Overexposure ENS 499122014-03-12T05:00:00012 March 2014 05:00:00 Agreement State Texas Agreement State Report - Potential Overexposure to a Radiographer'S Hand ENS 451712009-06-26T15:30:00026 June 2009 15:30:00 Agreement State Agreement State Report - Difficulty Retrieving Radiography Source 2025-10-27T05:00:00 | |