ENS 50745
ENS Event | |
|---|---|
21:15 Jan 16, 2015 | |
| Title | Agreement State Report - Potential Radiographer Excessive Exposure |
| Event Description | The following report was received from the State of Louisiana via email:
Event Date and Time: 01/16/2015, around [1515 CST] a radiography crew was working at the ExxonMobil Refinery on Scenic Highway, Baton Rouge, LA. The event was reported [about 1645 CST] on January 17, 2015, by a phone call from [an individual] who represented himself as the Corporate RSO. He stated he drove down on January 17, to evaluate and investigate this incident. He reported this incident appears to be a Human Error Potential Excessive Exposure. Event Location: ExxonMobil Refinery 4999 Scenic Highway. Baton Rouge, LA 70805. A temporary jobsite for Acuren Inspection. Event type: This is a potential excessive exposure involving a radiographer attempting to breakdown a radiography exposure setup. He attempted to disconnect the guide tube from the exposure device and the source was not locked in the shielded position. It was noticed that the locking device was red after the guide tube was handled to disconnect it from the exposure device. Notifications: LA DEQ [Department of Environmental Quality], Assessment, Radiation by direct phone call to our after hours answering system. The notification came in around [1645 CST] on January 17, 2015. Event Description: The radiography crew was making exposures on lower level equipment at the ExxonMobil Refinery. The crew was utilizing [about] 38 Ci of Ir-192. The crew attempted to breakdown/disconnect the equipment after the exposures. The guide tube would not disconnect. The 2nd hand of the crew manipulated the drive cable that returned the source into the shielded position. A quarter turn on the crank shielded the source. The radiographer and his equipment were checked. His pocket dosimeter was off scale, but he claims his Alarm Rate Alarm meter did not alarm. A second check of the Alarm Rate Meter revealed the unit did alarm, but it was a weak alarm. Estimated dose calculations were done for his whole body and extremities. His whole-body estimated dose was 3.3 Rads and his extremity dose was estimated at 206 Rads to his hands. These were calculated on a one minute exposure where a .5 minute is more realistic. The exposed radiographer was taken to Core Occupational Medicine for examination, x-rays and blood work. He is being monitored and examined every other day. At this time he has been asymptomatic for an excessive radiation exposure. The Licensee is conducting reenactments. This incident is not considered closed by the Department [LA DEQ]. The investigation findings will be updated when they become available. The equipment was all QSA equipment loaded with 38 Ci Ir-192. This appears to be an operator error exposure. The source is secure from removal and unnecessary exposure. This event is not closed and additional investigation and evaluation will continue. The source is in a safe shielded position and no threat to workers or the general public. Transport vehicle description : N/A This was at a temporary job site inside the ExxonMobil Refinery located in Baton Rouge, LA. License Numbers: LA-7072-L01, AI 126755 Louisiana Event Number: LA1500002 |
| Where | |
|---|---|
| Acuren Inspection, Inc. La Porte, Louisiana (NRC Region 4) | |
| License number: | LA-7072-L01 |
| Organization: | Louisiana Radiation Protection Div |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+90.07 h3.753 days <br />0.536 weeks <br />0.123 months <br />) | |
| Opened: | Joseph Noble 15:19 Jan 20, 2015 |
| NRC Officer: | Vince Klco |
| Last Updated: | Jan 20, 2015 |
| 50745 - NRC Website | |
Acuren Inspection, Inc. with Agreement State | |
WEEKMONTHYEARENS 580092025-10-27T05:00:00027 October 2025 05:00:00
[Table view]Agreement State Worker Potentially Exceeded Occupational Dose Limit ENS 567732023-10-02T20:30:0002 October 2023 20:30:00 Agreement State Disconnected Radiography Source ENS 567682023-09-30T05:00:00030 September 2023 05:00:00 Agreement State Radiography Source Stuck Unshielded and Recovered ENS 566042023-06-30T21:50:00030 June 2023 21:50:00 Agreement State Missing Radiography Camera ENS 559352022-06-11T12:47:00011 June 2022 12:47:00 Agreement State Armed BREAK-IN at Licensed Facility ENS 557912022-03-12T06:00:00012 March 2022 06:00:00 Agreement State Radiography Source Failure to Retract ENS 553662021-07-20T20:30:00020 July 2021 20:30:00 Agreement State Radiography Camera Source Disconnect ENS 551832021-04-08T05:00:0008 April 2021 05:00:00 Agreement State Source Lost During Shipment ENS 550192020-12-02T22:40:0002 December 2020 22:40:00 Agreement State Radiography Source Stuck within Source Guide Tube ENS 529972017-10-02T05:00:0002 October 2017 05:00:00 Agreement State Agreement State Report - Radiography Source Disconnected While Working in the Field ENS 527592017-05-15T05:00:00015 May 2017 05:00:00 Agreement State Agreement State Report - Potential Excessive Exposure of Radiographer ENS 523142016-10-20T05:00:00020 October 2016 05:00:00 Agreement State Agreement State Report - Unable to Retract Radiography Camera Source ENS 523082016-10-19T06:00:00019 October 2016 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 518392016-03-30T04:00:00030 March 2016 04:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 518032016-03-02T17:30:0002 March 2016 17:30:00 Agreement State Agreement State - Radiography Camera Source Unable to Be Retracted ENS 507452015-01-16T21:15:00016 January 2015 21:15:00 Agreement State Agreement State Report - Potential Radiographer Excessive Exposure ENS 502392014-06-29T21:25:00029 June 2014 21:25:00 Agreement State Agreement State Report - Inability to Retract Radiography Source to Its Fully Shielded Position ENS 500142014-04-09T15:30:0009 April 2014 15:30:00 Agreement State Agreement State Report - Radiographer Overexposure ENS 499122014-03-12T05:00:00012 March 2014 05:00:00 Agreement State Texas Agreement State Report - Potential Overexposure to a Radiographer'S Hand ENS 451712009-06-26T15:30:00026 June 2009 15:30:00 Agreement State Agreement State Report - Difficulty Retrieving Radiography Source 2025-10-27T05:00:00 | |