ENS 51839
ENS Event | |
|---|---|
04:00 Mar 30, 2016 | |
| Title | Agreement State Report - Radiography Camera Stuck Source |
| Event Description | The following information was received from the State of Ohio by email:
On March 30, 2016 at approximately [1250 EDT] the Bureau of Environmental Health and Radiation Protection (BEHRP) received a phone call from licensee's RSO that an industrial radiography crew working on a water tank construction job in Groveport, Ohio had a source stuck in the guide tube of a QSA Model 880D camera and were unable to retrieve the back into the camera. The source in use was 75 Curies of Iridium-192. The incident occurred at approximately [1225 EDT]. The stuck source was discovered after a shot time had ended and the radiography crew attempted to crank the source back in to the camera. The radiography crew conducted surveys of the area and moved boundaries out 2 mR/hr or less. The cause of the stuck source was due to a magnetic stand becoming dislodged during radiography operations, which fell onto the guide tube, crimping it, and preventing retraction of the source.
A BEHRP inspector was immediately dispatched to the job-site and arrived there at approximately [1320 EDT]. The inspector met with the licensee's customer and reviewed the actions taken by the radiography crew to establish new barriers and prevent access to the site. The licensee's trained retrieval personnel dispatched to the site arrived a short time later. After a thorough review of the incident and work area, the licensee's response team was able to retrieve the source, which was completed at approximately [1600 EDT] that afternoon. The maximum dose received by any individual involved in the recovery effort was 50 mR. The camera and guide tube will be returned to manufacturer for repair. QSA Global Camera,Serial Number-D8042; Source Serial Number-29222G. Ohio Event- OH160002 Notified the R3DO (Pelke) and the NMSS Events Notification via email. |
| Where | |
|---|---|
| Acuren Inspection, Inc. Dayton, Ohio (NRC Region 3) | |
| License number: | 03320 99 0006 |
| Organization: | Ohio Bureau Of Radiation Protection |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+34.12 h1.422 days <br />0.203 weeks <br />0.0467 months <br />) | |
| Opened: | Stephen James 14:07 Mar 31, 2016 |
| NRC Officer: | Vince Klco |
| Last Updated: | Mar 31, 2016 |
| 51839 - NRC Website | |
Acuren Inspection, Inc. with Agreement State | |
WEEKMONTHYEARENS 580092025-10-27T05:00:00027 October 2025 05:00:00
[Table view]Agreement State Worker Potentially Exceeded Occupational Dose Limit ENS 567732023-10-02T20:30:0002 October 2023 20:30:00 Agreement State Disconnected Radiography Source ENS 567682023-09-30T05:00:00030 September 2023 05:00:00 Agreement State Radiography Source Stuck Unshielded and Recovered ENS 566042023-06-30T21:50:00030 June 2023 21:50:00 Agreement State Missing Radiography Camera ENS 559352022-06-11T12:47:00011 June 2022 12:47:00 Agreement State Armed BREAK-IN at Licensed Facility ENS 557912022-03-12T06:00:00012 March 2022 06:00:00 Agreement State Radiography Source Failure to Retract ENS 553662021-07-20T20:30:00020 July 2021 20:30:00 Agreement State Radiography Camera Source Disconnect ENS 551832021-04-08T05:00:0008 April 2021 05:00:00 Agreement State Source Lost During Shipment ENS 550192020-12-02T22:40:0002 December 2020 22:40:00 Agreement State Radiography Source Stuck within Source Guide Tube ENS 529972017-10-02T05:00:0002 October 2017 05:00:00 Agreement State Agreement State Report - Radiography Source Disconnected While Working in the Field ENS 527592017-05-15T05:00:00015 May 2017 05:00:00 Agreement State Agreement State Report - Potential Excessive Exposure of Radiographer ENS 523142016-10-20T05:00:00020 October 2016 05:00:00 Agreement State Agreement State Report - Unable to Retract Radiography Camera Source ENS 523082016-10-19T06:00:00019 October 2016 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 518392016-03-30T04:00:00030 March 2016 04:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 518032016-03-02T17:30:0002 March 2016 17:30:00 Agreement State Agreement State - Radiography Camera Source Unable to Be Retracted ENS 507452015-01-16T21:15:00016 January 2015 21:15:00 Agreement State Agreement State Report - Potential Radiographer Excessive Exposure ENS 502392014-06-29T21:25:00029 June 2014 21:25:00 Agreement State Agreement State Report - Inability to Retract Radiography Source to Its Fully Shielded Position ENS 500142014-04-09T15:30:0009 April 2014 15:30:00 Agreement State Agreement State Report - Radiographer Overexposure ENS 499122014-03-12T05:00:00012 March 2014 05:00:00 Agreement State Texas Agreement State Report - Potential Overexposure to a Radiographer'S Hand ENS 451712009-06-26T15:30:00026 June 2009 15:30:00 Agreement State Agreement State Report - Difficulty Retrieving Radiography Source 2025-10-27T05:00:00 | |