ENS 50014
ENS Event | |
---|---|
15:30 Apr 9, 2014 | |
Title | Agreement State Report - Radiographer Overexposure |
Event Description | The following information was received from the Ohio Bureau of Radiation Protection via email:
The corporate RSO for Acuren Inspection made an immediate telephone notification under OAC [Ohio Administrative Code] 3701:1-38-21(B)(1) [same as 10 CFR 20.2202(a)(1)] to the Ohio Department of Health Bureau of Radiation Protection at 1320 [EDT on] April 9, 2014, to report a radiographer overexposure at a temporary job site in Marietta, OH. The event happened about 1100-1130 [EDT] this morning. The initial estimates regarding the male radiographer is that he may have received a 15 Rem whole body exposure and an estimated 3000-5000 Rem to the hand. The radiographer's whole body dosimeter is being sent off for immediate processing. The radiographer has been sent for medical attention. REAC/TS [Radiation Emergency Assistance Center/Training Site] was contacted by the licensee who gave REAC/TS the contact information for the attending physician of the radiographer. The radiographer was working with an 88 Ci Ir-192 source at the time. The radiographer supposedly had all his dosimetry and a survey meter at the time of the incident. The corporate RSO and a local [RSO] are both enroute to the temporary job site. Sequence of events: The radiographer had sat down and was chatting while waiting for an exposure to complete. At the end of the shot time, he had assumed that the other radiographer had retracted the source and proceeded to set up for the next shot. When he noticed that the other radiographer was not present he went back and checked to find that the source had not been cranked back. The [State of Ohio] Department will have an inspector on scene in the morning to investigate the incident and also to observe and review the incident reenactments. Ohio event report number 2014-007.
On April 10, 2014, the [State of Ohio] Department performed an onsite inspection and observed the licensee perform a reenactment of the incident scenario. It was determined that the radiographer did not handle the end of the source tube with the source in it and did not receive the initially assumed hand dose. The whole body deep dose is still expected to be about 15 Rem. The hand dose is expected to be on the order of the whole body dose, about 15 Rem. During the reactive inspection, the [State of Ohio] Department found that the radiographer's alarming rate meter had a dead battery, and the survey meter was not functional and had not been checked that day. The Assistant Radiographer was trailing the radiographer approximately one and a half minutes in entering the shielded bunker, and it was the assistant radiographer's alarming rate meter and survey instrument that identified the presence of the exposed source. The source collimator was not being used in the bunker, and so the 89 Ci Ir-192 source was not shielded. Notified R3DO (Pelke), FSME Duty Officer (McIntosh), and FSME Event Resource.
The Acuren Inspection Services RSO has provided the Department [State of Ohio] with the following updates: (1) The radiographer's whole body dosimeter reading was 836 mRem. (2) Based on the dose estimates from the scene reenactments, Acuren will assign the radiographer a whole body dose of 13 Rem, and an extremity dose of 6.5 Rem. [The radiographer's chest was much closer to the source than his dosimeter was.] (3) The radiographer will be under continued medical surveillance and REAC/TS will remain involved. Notified R3DO (Pelke), FSME Duty Officer (McIntosh), and FSME Event Resource. |
Where | |
---|---|
Acuren Inspection, Inc. Dayton, Ohio (NRC Region 3) | |
License number: | 03320 99 0006 |
Organization: | Ohio Bureau Of Radiation Protection |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+-1.03 h-0.0429 days <br />-0.00613 weeks <br />-0.00141 months <br />) | |
Opened: | Karl Vonahn 14:28 Apr 9, 2014 |
NRC Officer: | John Shoemaker |
Last Updated: | Apr 11, 2014 |
50014 - NRC Website | |
Acuren Inspection, Inc. with Agreement State | |
WEEKMONTHYEARENS 567732023-10-02T20:30:0002 October 2023 20:30:00
[Table view]Agreement State Disconnected Radiography Source ENS 567682023-09-30T05:00:00030 September 2023 05:00:00 Agreement State Radiography Source Stuck Unshielded and Recovered ENS 566042023-06-30T21:50:00030 June 2023 21:50:00 Agreement State Missing Radiography Camera ENS 559352022-06-11T12:47:00011 June 2022 12:47:00 Agreement State Armed BREAK-IN at Licensed Facility ENS 557912022-03-12T06:00:00012 March 2022 06:00:00 Agreement State Radiography Source Failure to Retract ENS 553662021-07-20T20:30:00020 July 2021 20:30:00 Agreement State Radiography Camera Source Disconnect ENS 551832021-04-08T05:00:0008 April 2021 05:00:00 Agreement State Source Lost During Shipment ENS 550192020-12-02T22:40:0002 December 2020 22:40:00 Agreement State Radiography Source Stuck within Source Guide Tube ENS 529972017-10-02T05:00:0002 October 2017 05:00:00 Agreement State Agreement State Report - Radiography Source Disconnected While Working in the Field ENS 527592017-05-15T05:00:00015 May 2017 05:00:00 Agreement State Agreement State Report - Potential Excessive Exposure of Radiographer ENS 523142016-10-20T05:00:00020 October 2016 05:00:00 Agreement State Agreement State Report - Unable to Retract Radiography Camera Source ENS 523082016-10-19T06:00:00019 October 2016 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 518392016-03-30T04:00:00030 March 2016 04:00:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 518032016-03-02T17:30:0002 March 2016 17:30:00 Agreement State Agreement State - Radiography Camera Source Unable to Be Retracted ENS 507452015-01-16T21:15:00016 January 2015 21:15:00 Agreement State Agreement State Report - Potential Radiographer Excessive Exposure ENS 502392014-06-29T21:25:00029 June 2014 21:25:00 Agreement State Agreement State Report - Inability to Retract Radiography Source to Its Fully Shielded Position ENS 500142014-04-09T15:30:0009 April 2014 15:30:00 Agreement State Agreement State Report - Radiographer Overexposure ENS 499122014-03-12T05:00:00012 March 2014 05:00:00 Agreement State Texas Agreement State Report - Potential Overexposure to a Radiographer'S Hand ENS 451712009-06-26T15:30:00026 June 2009 15:30:00 Agreement State Agreement State Report - Difficulty Retrieving Radiography Source 2023-09-30T05:00:00 | |