05000528/LER-2009-001, For Palo Verde, Units 1, 2, & 3 - Regarding Safety Injection System Recirculation Alignment Results in Unanalyzed Condition

From kanterella
(Redirected from 05000528/LER-2009-001)
Jump to navigation Jump to search
For Palo Verde, Units 1, 2, & 3 - Regarding Safety Injection System Recirculation Alignment Results in Unanalyzed Condition
ML091210112
Person / Time
Site: Palo Verde  
Issue date: 04/20/2009
From: Mims D
Arizona Public Service Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
102-05994-DCM/DCE LER 09-001-00
Download: ML091210112 (12)


LER-2009-001, For Palo Verde, Units 1, 2, & 3 - Regarding Safety Injection System Recirculation Alignment Results in Unanalyzed Condition
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications
5282009001R00 - NRC Website

text

10 CFR 50.73 AA subsidiary of Pinnacle West Capital Corporation Dwight C. Mims Mail Station 7605 Palo Verde Nuclear Vice President Tel. 623-393-5403 P.O. Box 52034 Generating Station Regulatory Affairs and Plant Improvement Fax 623-393-6077 Phoenix, Arizona 85072-2034 102-05994-DCM/DCE April 20, 2009 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2, and 3 Docket No. STN 50-528, STN 50-529, and STN 50-530 License No. NPF 41, NPF 51, and NPF 74 Licensee Event Report 2009-001-00 Enclosed, please find Licensee Event Report (LER) 50-528/2009-001-00 that has been prepared and submitted pursuant to 10 CFR 50.73. This LER reports an unanalyzed condition that was the result of certain alignments of the safety injection system used to recirculate the refueling water tank while in Modes 1 through 4 in each unit.

In accordance with 10 CFR 50.4, copies of this LER are being forwarded to the NRC Regional Office, NRC Region IV and the Senior Resident Inspector. If you have questions regarding this submittal, please contact Ray Buzard, Section Leader, Regulatory Affairs, at (623) 393-5317.

No commitments are being made to the NRC by this letter.

Sincerely, DCM/REB/DCE/gat Enclosure cc:

E. E. Collins Jr.

NRC Region IV Regional Administrator J. R. Hall NRC NRR Project Manager R. I. Treadway NRC Senior Resident Inspector for PVNGS A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway Comanche Peak

  • Diablo Canyon
  • Palo Verde San Onofre
  • Wolf Creek

NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 08/31/2010

9-2007)

, the NRC may digits/characters for each block) not conduct or sponsor, and a person is not required to respond to, the information collection.

3. PAGE Palo Verde Nuclear Generating Station Unit 1 05000528 1 OF 11
4. TITLE Safety Injection System Recirculation Alignment Results in Unanalyzed Condition
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED MONTH REI FACILITY NAME DOCKET NUMBER MONTH DAY YEAR YEAR SEQUENTIAL RE.

MONTH DAY YEAR IPVNGS Unit 2 05000529 j

I FACILITY NAME DOCKET NUMBER 02 18 2009 2009 - 001 -

00 04 20 2009 [PVNGS Unit 3 05000530

9. OPERATING MODE
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR§: (Check all that apply)

C1 20.2201(b)

El 20.2203(a)(3)(i)

El 50.73(a)(2)(i)(C) 0 50.73(a)(2)(vii) 1 /1/1 El 20.2201(d)

El 20.2203(a)(3)(ii)

[I 50.73(a)(2)(ii)(A)

El 50.73(a)(2)(viii)(A)

El 20.2203(a)(1)

[I 20.2203(a)(4) 0 50.73(a)(2)(ii)(B)

El 50.73(a)(2)(viii)(B)

[I 20.2203(a)(2)(i)

[I 50.36(c)(1)(i)(A)

El 50.73(a)(2)(iii)

El 50.73(a)(2)(ix)(A)

10. POWER LEVEL [E

20.2203(a)(2)(ii) 0l 50.36(c)(1)(ii)(A)

El 50.73(a)(2)(iv)(A)

El 50.73(a)(2)(x)

[: 20.2203(a)(2)(iii)

El 50.36(c)(2)

[3 50.73(a)(2)(v)(A)

El 73.71 (a)(4)

El 20.2203(a)(2)(iv)

El 50.46(a)(3)(ii) 0 50.73(a)(2)(v)(B)

[1 73.71 (a)(5) 100 I 100 / 100 El 20.2203(a)(2)(v)

El 50.73(a)(2)(i)(A) 0 50.73(a)(2)(v)(C)

E] OTHER El 20.2203(a)(2)(vi) 0D 50.73(a)(2)(i)(B) 0 50.73(a)(2)(v)(D)

Specify in Abstract below or in (if more space is required, use additional copies of (if more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies of NRC Form 366A)

Figure B - Post "RAS" Containment Spray System Full-flow Recirculation Alignment Note This is a simplified drawing for the Containment Spray full-flow recirculation alignment only. It does not include all of the piping or valves that would be used for LPSI full-flow recirculation.PRINTED ON RECYCLED PAPER