Finding | |
---|---|
Title | Inadequate Modification of Safety Related Accumulators |
Description | The inspectors identified a Green non-cited violation of 10 CFR 50, Appendix B, Criterion III, Design Control, for the failure to assure that a modification to the main steam and main feedwater isolation valve accumulators was suitable for the reliable operation of these components. Specifically, on September 4, 2009, the licensee failed to assess the suitability of a small dead band for a thermal relief valve in the accumulator valve manifold assembly and the impact on reliable operation of the associated valves. The licensee entered this issue into the corrective action program as Palo Verde Action Request 4429273. The licensee isolated the thermal relief valve from the actuators. The failure to assure that the modification of the main steam and main feedwater isolation valve accumulators was suitable for the reliable operation of these components was a performance deficiency. The performance deficiency is more than minor, and therefore is a finding, because it was associated with the Mitigating Systems Cornerstone attribute of equipment performance and adversely affects the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The inspectors evaluated the significance of the issue under the Significance Determination Process, as defined in Inspection Manual Chapter 0609.04, Initial Characterization of Findings, and 0609 Appendix A, The Significance Determination Process (SDP) for Findings at-Power. The inspectors concluded the finding was of very low safety significance (Green) because all questions in Exhibit 2 could be answered in the negative. The inspectors determined that the finding had a cross-cutting aspect in the area of human performance associated with resources component because the licensee did not maintain design margins by minimizing long standing equipment issues. |
Site: | Palo Verde ![]() |
---|---|
Report | IR 05000528/2013005 Section 1R18 |
Date counted | Dec 31, 2013 (2013Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.18 |
Inspectors (proximate) | T Brown D Reinert I Anchondo J Laughlin J O'Donnell L Carson M Baquera N Taylor S Graves |
Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
CCA | H.6, Design Margins |
INPO aspect | WP.2 |
' | |
Finding - Palo Verde - IR 05000528/2013005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Palo Verde) @ 2013Q4
Self-Identified List (Palo Verde)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||