Finding | |
---|---|
Title | Failure to completely close the spent fuel pool valve resulted in a loss of spent fuel pool water inventory. |
Description | A self-revealing noncited violation of Technical Specification 5.4.1.a was identified for the failure to close Valve EC-V025 during a lineup to recirculate the refueling water storage tank through the spent fuel pool cleanup system. These two systems were cross-connected for approximately 5 minutes on July 26, 2008, which resulted in approximately 1500 gallons of spent fuel pool water being inadvertently transferred to the refueling water storage tank. The licensee entered this issue into their corrective action program as Condition Report 2008-003663. Failure to completely close Valve EC-V025 was a performance deficiency. This finding is more than minor because it is associated with the barrier integrity cornerstone attribute of configuration control and affected the cornerstone objective to maintain functionality of the spent fuel pool system. Using Manual Chapter 0609.04, Phase 1 - Initial Screening and Characterization of Findings, this finding was determined be of very low safety significance because the finding affected only the barrier function of the spent fuel pool. The inspectors determined that the finding has a problem identification and resolution crosscutting aspect in the area associated with the corrective action program because Wolf Creek did not take appropriate corrective actions to address the adverse trend in manual valve stem friction in a timely manner, commensurate with its safety significance and complexity P.1(d) (Section 40A2). |
Site: | Wolf Creek ![]() |
---|---|
Report | IR 05000482/2008004 Section 4OA2 |
Date counted | Sep 30, 2008 (2008Q3) |
Type: | NCV: Green |
cornerstone | Barrier Integrity |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | R Deese D Dumbacher S Cochrum C Long P Alter J Groom W Schaup R Hickok |
CCA | P.3, Resolution |
INPO aspect | PI.3 |
' | |
Finding - Wolf Creek - IR 05000482/2008004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Wolf Creek) @ 2008Q3
Self-Identified List (Wolf Creek)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||