Finding | |
|---|---|
| Title | Failure to Take Timely Corrective Action To Establish Monitoring Frequency of AFW Pump Governor Null Set Drift |
| Description | The team identified a violation of 10 CFR Part 50 Appendix B Criterion XVI because the licensee failed to take timely corrective actions to address a previously identified finding. Finding 05000482/2008010 was issued because the licensee had failed to establish an acceptable monitoring frequency on their turbine driven auxiliary feedwater pump speed governor null-drift as recommended by a Part 21 report from Engine Systems, Inc. The corrective actions to establish the monitoring for the null-drift were not implemented. The team determined that this was a performance deficiency because the licensee had committed to take corrective actions in response to the previous non-cited violation but failed to do so in a timely manner. The team determined that this violation was greater than minor because it met the intent of Manual Chapter 0612, Appendix E, Example 4.a., in that, there were several examples of the licensee failing to take corrective actions in response to NRC identified non- cited violations and findings, indicating that The licensee routinely failed to perform engineering evaluations on similar issues. The team performed a Phase I Significance Determination Process evaluation and determined that the violation was screened as being very low safety significance, Green, because all of the answers to the Phase I Worksheet Mitigating Systems Column were no. The team also determined that this finding has crosscutting aspects in the problem identification and resolution area associated with the corrective action program in that the licensee failed to implement timely or effective corrective actions (P.1(d) (Section 40A2.e (4)) |
| Site: | Wolf Creek |
|---|---|
| Report | IR 05000482/2008006 Section 4OA2 |
| Date counted | Mar 31, 2008 (2008Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | S Cochrum J Adams C Long D Proulx H Abuseini L Smith |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |
Finding - Wolf Creek - IR 05000482/2008006 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Wolf Creek) @ 2008Q1
Self-Identified List (Wolf Creek)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||