Title | Failure to Accomplish an Operability Determination In Accordance With Procedures |
Description | The team identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to accomplish an operability determination in accordance with procedure EN-OP-104, Operability Determination Process, Revision 8. Specifically, the licensee referenced non-conservative data, contrary to steps 5.5 and 5.11 of procedure EN-OP-104, when assessing the reduced reliability of Masterpact circuit breakers as a degraded or nonconforming condition. The licensee restored compliance by completing a design modification to eliminate the failure mode and initiated Condition Report CR-RBS-2015-03952. This performance deficiency is more than minor, and therefore a finding, because it is associated with the equipment performance attribute of the Mitigating Systems Cornerstone, and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the reliability of components powered by Masterpact circuit breakers was reduced and, by justifying operability using non-conservative data, the licensee did not recognize the actual unreliability. The team performed an initial screening of the finding in accordance with NRC Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power. Using Inspection Manual Chapter 0609, Appendix A, Exhibit 2, Mitigating Systems Screening Questions, the finding was of very low safety significance (Green) because it: (1) was not a deficiency affecting the design or qualification of a mitigating structure, system, or component, and did not result in a loss of operability or functionality; (2) did not represent a loss of system and/or function; (3) did not represent an actual loss of function of at least a single train for longer than its technical specification allowed outage time, or two separate safety systems out-of-service for longer than their technical specification allowed outage time; and (4) did not represent an actual loss of function of one or more non-technical specification trains of equipment designated as high safety-significant in accordance with the licensees maintenance rule program. This finding has a conservative bias cross-cutting aspect within the human performance area because the licensee failed to use decision-making practices that emphasize prudent choices over those that are simply allowable. Specifically, the licensee did not consider that the failure mechanism only occurs on a close command. Instead, the licensee included opening commands when summing the total demands and this resulted in a non-conservative failure rate [H.14]. |
Site: | River Bend |
---|---|
Report | IR 05000458/2015010 Section 4OA5 |
Date counted | Mar 31, 2016 (2016Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 93812 |
Inspectors (proximate) | C Smith D Bradley E Uribe J Watkins R Deese T Pruett |
Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion V Technical Specification |
CCA | H.14, Conservative Bias |
INPO aspect | DM.2 |
' | |