Finding | |
---|---|
Title | Failure to Promptly Correct Conditions Adverse to Quality |
Description | The inspectors identified a finding of very low safety significance and an associated NCV of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, when licensee personnel failed to promptly correct conditions adverse to quality. Specifically, from 2006 to 2011, licensee personnel failed to correct a poor material condition in the auxiliary building ventilation (VA) intake plenums that resulted in clogging of floor drains and water leakage into electrical penetration and cable spreading room areas; and from 2010 to 2012, the licensee failed to correct a degraded floor drain in the Unit 2 miscellaneous electrical equipment room (MEER) that was next to a safety shower adjacent to a safety-related direct current (DC) bus. The licensee entered this issue into their CAP as IRs 1291696 and 1332289. Corrective actions included cleaning and re-coating the VA intake plenums and routing out the floor drains in the MEERs. The finding was determined to be more than minor because it was associated with the Design Control and Protection Against External Events attributes of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage.). Specifically, the licensee failed to promptly correct degraded and clogged auxiliary building floor drains or the poor material condition in the VA intake plenum. The inspectors evaluated this finding using the SDP in accordance with IMC 0609, Significance Determination Process, Attachment 0609.04, Phase I - Initial Screening and Characterization of Findings, and determined that the finding affected the Flood Protection Degraded Function of the Mitigating Systems Cornerstone, per Table 2. The inspectors answered Yes to Question 5 in Table 4a, which directed the inspectors to Table 4b since the issue was related to flood protection. The inspectors answered No to Question 2 of Table 4b because the floor drains were degraded, but the pooling water in the VA plenums or MEERs would not have likely resulted in a plant trip or transient. As a result, the issue screened as having very low safety significance (Green). This finding had a cross-cutting aspect in the Corrective Action Program component of the Problem Identification and Resolution cross-cutting area because the licensee failed to properly classify, prioritize, or evaluate conditions adverse to quality associated with auxiliary building floor drains and VA intake plenum such that the conditions were promptly corrected |
Site: | Braidwood |
---|---|
Report | IR 05000456/2012002 Section 1R06 |
Date counted | Mar 31, 2012 (2012Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.06 |
Inspectors (proximate) | A Garmoe B Jose E Duncan J Benjamin J Gilliam M Holmberg M Perry |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |
Finding - Braidwood - IR 05000456/2012002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Braidwood) @ 2012Q1
Self-Identified List (Braidwood)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||