Finding | |
|---|---|
| Title | Inadequate Gasket Installation Causes Diesel Jacket Water Leak |
| Description | The inspectors reviewed a self-revealing non-cited violation of Technical Specification 5.4.1.a for the failure of the licensee to adequately install a gasket in accordance with procedure. As a result, the diesel generator jacket water connection leaked above the Final Safety Analysis Report allowable value for a seven day technical specification mission time for the diesel generator. The licensee replaced the leaking gasket and entered the finding into the corrective action program as Condition Report CR-2012-006536. The licensees failure to adequately install a gasket in accordance with procedure was a performance deficiency which resulted in a diesel generator jacket water leak. The finding was more than minor because it was associated with the human performance attribute of the mitigating systems cornerstone and adversely affected the cornerstone objective to ensure the reliability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the jacket water leakage rate exceeded the Final Safety Analysis Report allowable value for a seven day diesel generator technical specification mission time. Using NRC Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, the finding screened to a detailed risk evaluation because it represented an actual loss of function of a single train for greater than its technical specification allowed outage time. A senior reactor analyst determined that the risk significance was of very low safety significance because the diesel generator was always capable of functioning for greater than the probabilistic risk assessment mission time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The finding has a human performance cross-cutting aspect associated with resources because the licensee failed to maintain design margins and minimize long-standing equipment issues. |
| Site: | Comanche Peak |
|---|---|
| Report | IR 05000445/2012004 Section 1R15 |
| Date counted | Sep 30, 2012 (2012Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | G Guerra W Walker B Tindell D Proulx J Kramer K Wood |
| CCA | H.6, Design Margins |
| INPO aspect | WP.2 |
| ' | |
Finding - Comanche Peak - IR 05000445/2012004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Comanche Peak) @ 2012Q3
Self-Identified List (Comanche Peak)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||