Finding | |
|---|---|
| Title | Failure to Have an Adequate Procedure to Test Main Stream Safety Valves |
| Description | The inspectors documented a self-revealing noncited violation of Technical Specification 5.4.1a (Procedures) for an inadequate test procedure that resulted in inadvertently holding open a main steam safety valve at power. During testing, a test engineer separated a quick disconnect fitting in accordance with the procedural instructions. The action sealed in nitrogen pressure in the test rig and caused the valve to remain held open. In response to the event, operators reduced reactor power to compensate for the partially open safety valve until maintenance personnel closed the valve. The licensee entered the finding into their corrective action program as Smart Form SMF-2008-002946. The finding was more than minor because it was associated with the procedure quality attribute of the initiating events cornerstone, and directly affected the cornerstone objective to limit the likelihood of those events that upset plant stability during power operations. Using Manual Chapter 0609, Attachment 4, Phase 1 - Initial Screening and Characterization of Findings, the finding had very low safety significance because it did not contribute to the likelihood of mitigating equipment being unavailable. This finding did not have a crosscutting aspect because the procedure section was last revised several years earlie |
| Site: | Comanche Peak |
|---|---|
| Report | IR 05000445/2008005 Section 1R22 |
| Date counted | Dec 31, 2008 (2008Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.22 |
| Inspectors (proximate) | L Ricketson J Dixon K Clayton B Tharakan L Carson G Replogle B Tindell M Bloodgood D Reinert G Tutak J Kramer N Okonkwo N Hernandez |
| INPO aspect | |
| ' | |
Finding - Comanche Peak - IR 05000445/2008005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Comanche Peak) @ 2008Q4
Self-Identified List (Comanche Peak)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||