Finding | |
|---|---|
| Title | Inadequate Instructions Causes to Failure to Identify Fibrous Material in Containment |
| Description | The inspectors identified a noncited violation of Technical Specification 5.4.1a (Procedures) for the failure to have adequate instructions in place for containment walkdowns looking for fibrous material. As a result, the licensee entered a mode where the containment sumps were required to be operable with unidentified fibrous material in the containment. The licensee had not identified the material during several walkdowns in response to NRC Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation during Design Basis Accidents at Pressurized-Water Reactors, and failed to identify several additional instances of fibrous material after inspectors initially identified some of the material. The licensee entered the finding into their corrective action program for resolution as Smart Form SMF-2008-003587. The finding was more than minor because it was associated with the procedure quality attribute of the mitigating systems cornerstone, and it affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Using NRC Manual Chapter 0609, Attachment 4, Phase 1 Initial Screening and Characterization of Findings, the finding had very low safety significance because it did not represent a loss of system safety function or cause inoperability of a system or train. The finding had a Human Performance crosscutting aspect (work control component) in that the work instructions and pre-job brief failed to effectively incorporate job site conditions into the work instructions and consider that both sides of the seals required inspectio |
| Site: | Comanche Peak |
|---|---|
| Report | IR 05000445/2008005 Section 1R15 |
| Date counted | Dec 31, 2008 (2008Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | L Ricketson J Dixon K Clayton B Tharakan L Carson G Replogle B Tindell M Bloodgood D Reinert G Tutak J Kramer N Okonkwo N Hernandez |
| CCA | H.5, Work Management |
| INPO aspect | WP.1 |
| ' | |